Loading...
Backup Documents 06/11/2013 Item #16A 4 ORIGINAL DOCUMENTS CHECKLIST & ROUTING SLIP TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT TOA 1� THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGN �'1 Print on pink paper. Attach to original document. The completed routing slip and original documents are to be forwarded to the County Attorney Office at the time the item is placed on the agenda. All completed routing slips and original documents must be received in the County Attorney Office no later than Monday preceding the Board meeting. Complete routing lines#1 through#2 as appropriate for additional signatures,dates,and/or information needed. If the document is already complete with the exception of the Chairman's signature,draw a line through routing lines#1 through#2,complete the checklist,and forward to the County Attorney Office. Route to Addressee(s) (List in routing order) Office Initials Date 1. 2. 3. County Attorney Office County Attorney Office U\413 4. BCC Office Board of County 6-t{Out tkX Commissioners _ 6 4703 5. Minutes and Records Clerk of Court's Office) PRIMARY CONTACT INFORMATION Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the addressees above,may need to contact staff for additional or missing information. Name of Primary Staff John Houldsworth Phone Number x-5757 Contact/ Department Agenda Date Item was June 11,2013 / Agenda Item Number 16-A4 Approved by the BCC Type of Document Plat Number of Original One Attached Documents Attached PO number or account number if document is to be recorded INSTRUCTIONS & CHECKLIST Initial the Yes column or mark"N/A"in the Not Applicable column,whichever is Yes N/A(Not appropriate. (Initial) Applicable) 1. Does the document require the chairman's original signature? JH 2. Does the document need to be sent to another agency for additional signatures? If yes, 0/A provide the Contact Information(Name;Agency;Address;Phone)on an attached sheet. 3. Original document has been signed/initialed for legal sufficiency. (All documents to be JH signed by the Chairman,with the exception of most letters,must be reviewed and signed by the Office of the County Attorney. 4. All handwritten strike-through and revisions have been initialed by the County Attorney's N/A Office and all other parties except the BCC Chairman and the Clerk to the Board 5. The Chairman's signature line date has been entered as the date of BCC approval of the J}l document or the final negotiated contract date whichever is applicable. 6. "Sign here"tabs are placed on the appropriate pages indicating where the Chairman's signature and initials are required. 7. In most cases(some contracts are an exception),the original document and this routing slip N/A should be provided to the County Attorney Office at the time the item is input into SIRE. Some documents are time sensitive and require forwarding to Tallahassee within a certain time frame or the BCC's actions are nullified. Be aware of your deadlines! 8. The document was approved by the BCC on June 11,2013 and all changes made oti, during the meeting have been incorporated in the attached document. The County Attorney's Office has reviewed the changes,if applicable. \ 9. Initials of attorney verifying that the attached document is the version approved by the /y BCC,all changes directed by the BCC have been made,and the document is ready for the Chairman's signature. I:Forms/County Forms/BCC Forms/Original Documents Routing Slip WWS Original 9.03.04,Revised 1.26.05,Revised 2.24.05;Revised 11/30/12 ORIGINAL DOCUMENTS CHECKLIST & ROUTING SLIP TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGL1 ' Print on pink paper. Attach to original document. The completed routing slip and original documents are to be forwarded to the County Attorney Office at the time the item is placed on the agenda. All completed routing slips and original documents must be received in the County Attorney Office no later than Monday preceding the Board meeting. Complete routing lines#1 through#2 as appropriate for additional signatures,dates,and/or information needed. If the document is already complete with the exception of the Chairman's signature,draw a line through routing lines#1 through#2,complete the checklist,and forward to the County Attorney Office. Route to Addressee(s) (List in routing order) Office Initials Date 1. 2. 3. County Attorney Office County Attorney Office CO() (1)iaB 113 4. BCC Office Board of County G� Commissioners , (( 1E( 13 5. Minutes and Records Clerk of Court's Office PRIMARY CONTACT INFORMATION Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the addressees above,may need to contact staff for additional or missing information. Name of Primary Staff John Houldswo h Phone Number x-5757 Contact/ Department Agenda Date Item was June 11,2013 Agenda Item Number 16-A4 Approved by the BCC Type of Document Construction&Maintenance Agreement Number of Original Two Attached and Letter of Credit Documents Attached PO number or account number if document is to be recorded INSTRUCTIONS & CHECKLIST Initial the Yes column or mark"N/A"in the Not Applicable column,whichever is Yes N/A(Not appropriate. (Initial) Applicable) 1. Does the document require the chairman's original signature? JH 2. Does the document need to be sent to another agency for additional signatures? If yes, N/A provide the Contact Information(Name;Agency;Address;Phone)on an attached sheet. 3. Original document has been signed/initialed for legal sufficiency. (All documents to be JH signed by the Chairman,with the exception of most letters,must be reviewed and signed by the Office of the County Attorney. 4. All handwritten strike-through and revisions have been initialed by the County Attorney's N/A Office and all other parties except the BCC Chairman and the Clerk to the Board 5. The Chairman's signature line date has been entered as the date of BCC approval of the JH document or the final negotiated contract date whichever is applicable. 6. "Sign here"tabs are placed on the appropriate pages indicating where the Chairman's signature and initials are required. 7. In most cases(some contracts are an exception),the original document and this routing slip N'A should be provided to the County Attorney Office at the time the item is input into SIRE. Some documents are time sensitive and require forwarding to Tallahassee within a certain time frame or the BCC's actions are nullified. Be aware of your deadlines! 8. The document was approved by the BCC on June 11,2013 and all changes made during the meeting have been incorporated in the attached document. The County (pp Attorney's Office has reviewed the changes,if applicable. X11 9. Initials of attorney verifying that the attached document is the version approved by the BCC,all changes directed by the BCC have been made,and the document is ready for the Chairman's signature. I:Forms/County Forms!BCC Forms/Original Documents Routing Slip WWS Original 9.03.04,Revised 1.26.05,Revised 2.24.05;Revised 11/30/12 16 A4 MEMORANDUM Date: July 1, 2013 To: John Houldsworth, Senior Engineer Engineering Services Department From: Ann Jennejohn, Deputy Clerk Minutes & Records Department Re: The final Plat, Construction and Maintenance Agreement and Letter of Credit for "Bella Firenze" in the Treviso Bay Development Attached is the original Plat and copies of the Construction & Maintenance Agreement and Letter of Credit referenced above, (Item #16A4) approved by the Board of County Commissioners on Tuesday, June 11, 2013. If you need anything further, please feel free to contact me at 252-8406. Thank you. Attachment -OeV iCt ISOC2;a4-3 CONSTRUCTION AND MAINTENANCE AGREEMENT FOR SUBDIVISION IMPROVLE6 'F j 01 2, b) THIS CONSTRUCTION AND MAINTENANCE AGREEMENT FOR SUBDIVISION IMPROVEMENTS entered into this ` i`:4 day of June / / 20 13 between Lennar Homes LLC hereinafter referred to as"Developer", and the Board of County Commissioners of Collier County, Florida, hereinafter referred to as the "Board". RECITALS: A. Developer has, simultaneously with the delivery of this Agreement, applied for the approval by the Board of certain plat of a subdivision to be known as: Bella Firenze B. Chapters 4 and 10 of the Collier County land Development Code requires the Developer to post appropriate guarantees for the construction of the improvements required by said subdivision regulations, said guarantees to be incorporated in a bonded agreement for the construction of the required improvements. NOW, THEREFORE, in consideration of the foregoing premises and mutual covenants hereinafter set forth, Developer and the Board do hereby covenant and agree as follows: 1. Developer will cause to be constructed: 1146. 'R t1i avb1L i_S.iO tw1 tib if i'�1 i t�,� within 4'Z months from the date of approval of said subdivision plat, said improvements hereinafter referred to as the required improvements. 2. Developer herewith tenders its subdivision performance security (attached hereto as Exhibit "A" and by reference made a part hereof) in the amount of$2,316,333.00 - which amount represents 10% of the total contract cost to complete the construction plus 100%of the estimated cost to complete the required improvements at the date of this Agreement. 3. In the event of default by the Developer or failure of the Developer to complete such improvements within the time required by the Land Development Code, Collier may call upon the subdivision performance security to insure satisfactory completion of the required improvements. 4. The required improvements shall not be considered complete until such a statement of substantial completion by Developer's engineer along with the final project records have been furnished to be reviewed and approved by the County Manager or his designee for compliance with the Collier County Land Development Code. 5. The County Manager or his designee shall,within sixty(60) days of receipt of the statement of substantial completion, either: a) notify the Developer in writing of his preliminary approval of the improvements, therewith specifying those conditions which the Developer must fulfill in order to obtain the County Manager's approval of the improvements. However, in no event shall the County Manager or his designee refuse preliminary approval of the improvements if they are in fact constructed and submitted for approval in accordance with the requirements of this Agreement. 6. The Developer shall maintain all required Improvements for a minimum period of one year after preliminary approval by the County Manager or his designee. After the one year maintenance period by the Developer has terminated,the developer shall petition the County Manager or his designee to inspect the required improvements. The County Manager or his designee shall inspect the improvements and, if found to be still in compliance with the Land Development Code as reflected by final approval by the Board, the Board shall release the remaining 10% of the subdivision performance security. The Developer's responsibility for maintenance of the required Improvements shall continue unless or until the Board accepts maintenance responsibility for and by the County. 1 6 A 4 7. Six (6) months after the execution of this Agreement and once within every six (6) months thereafter the Developer may request the County Manager or his designee to reduce the dollar amount of the subdivision performance security on the basis of work complete. Each request for a reduction in the dollar amount of the subdivision performance security shall be accompanied by a statement of substantial completion by the Developer's engineer together with the project records necessary for review by the County Manager or his designee. The County Manager or his designee may grant the request for a reduction in the amount of the subdivision performance security for the improvements completed as of the date of the request. 8. In the event the Developer shall fail or neglect to fulfill its obligations under this Agreement, upon certification of such failure, the county Manager or his designee may call upon the subdivision performance security to secure satisfactory completion, repair and maintenance of the required improvements. The Board shall have the right to construct and maintain, or cause to be constructed or maintained, pursuant to public iadvertisement and receipt of acceptance of bids, the improvements required herein. The Developer/as principal under the subdivision performance security, shall be liable to pay and to indemnify the Board, upon completion of such construction, the final total cost to the Board thereof, including, but not limited to, engineering, legal and contingent costs,together with any damages, either direct or consequential\which the Board may sustain on account of the failure of the Developer to fulfill all of the provisions of th4 Agreement. 9. All of the terms, covenants an conditions herein contained are and shall be binding upon the Developer and the respective successors a d assigns of the Developer. IN WITNESS WHEREOF, the Board and t s Developer have caused this Agreement to be executed by their duly authorized representatives this it day of / esg- / , 20 . SIGNED IN THE PRESENCE OF: (Name of ntity) By: y Printed Name tl 14 Urf Printed Nar T,ti)tle (President VP, r CEO) (Provide Proper Evidence of Authority) Printed Name Gni/ ATTEST: 'i DWIGHT ROGK ;'CIFRK` BOARD OF CC N C MM SIONERS OF COLLIER t?' COUNTY, F OR D BY: 11 w.M e .. l- By: Deputy Clef y GEORGIA A. HILLER, ESQ. sig .' ,- CHAIRWOMAN Approved as to form and',' irled'i'h/ t l Detail by Entity Name Page 1 of 9 1 6 A4 FLORIDA DEPARTMENT OF STATEo r III '' ' CORPORATIONS' t • �° ` Detail by Entity Name Florida Limited Liability Company LENNAR HOMES, LLC Filing Information Document Number L06000114706 FEI/EIN Number 590711505 Date Filed 11/30/2006 State FL Status ACTIVE Effective Date 01/18/1954 Last Event LC AMENDMENT Event Date Filed 12/08/2009 Event Effective Date NONE Principal Address 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Changed: 01/07/2010 Mailing Address 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Changed: 01/07/2010 Registered Agent Name &Address C T CORPORATION SYSTEM 1200 S. PINE ISLAND RD. SUITE 250 PLANTATION, FL 33324 Address Changed: 03/31/2010 Manager/Member Detail Name &Address Title MGRM U.S. HOME CORPORATION http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail/EntityName/flal-10... 6/17/2013 Detail by Entity Name Page 3 of 9 700 NW 107TH AVE. � � � jG�, SUITE 400 MIAMI, FL 33172 Title VP GONZALEZ, CARLOS 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP GROSS, BRUCE 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP HIGGINS, ERIK R 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP HURST, BRYAN 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP JAFFE, JONATHAN M 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP MARLIN, CHRISTIAN L 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP McMURRAY, DARIN L 700 NW 107TH AVE. SUITE 400 MIAMI, FL 33172 Title VP McPHERSON, GREG http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail/EntityName/flal-10... 6/17/2013 16 A4 FIDELITY:. GUARANTY AND ACCEPTANCE. CORP , G0 HLIV 107 .AVENUE SUITE 24 ; 1'al iAP,1l E LOO, RI PA 3 3 1 72 PION,E ( 335) 553- 8724 IRREVOCABLE STANDBY LETTER OF CREDIT NO.FGAC-1.3E092 ISSUER: FIDELITY Y GUARANTY AND ACCEPTANCE C'C?R ?.(13L"IZE1 vAFTE R ISSUER") DATE OF ISSUE; JUNE 5,2033 PLACE OE EXPIRY: AT ISSUER'S COUNTERS LOCATED AT 700 NW 107 AVE;SI U TF 240 MIAMI, FLORIDA 331 DATE,OF EXPIRY: TE[TS i ETTER OF CREDIT SHALL BE. VALI') UNTIL JUNE 5, 2014. IT IS A CONDI"I'l()I\ OF HIS E.ET`1ER OF CREDIT TIE AT IT' SHALL BE AUTONIAI ICAL.I,Y E:Y71;.NDFI') R 1 i E t31 iT :\AILN1:)\IFN I FOR ADDIT�O\;:T. PI:RJC)DS OF ONE YE.A}2. FROM `I'IlE PRESENT OR ANY FUTURE EXPIRATION DATE HEREOF,UNLESS AT` LEAST SIXTY DAYS PRIOR TO ANY S UCH DA IE WE SHALL NOTIFY YOU BY REGISTERED l-1.'LI[_. OR HAND' DI IV'ERET) NO'S II.ICA[IE.'N" AT T1'•IE, .A'E30VE ADDRESS THAT WE ELECT NOT TO CONSIDER- THIS I:_E't CE:,R: OF CREDIT EXTENDED FOR ANY SUCH ADDITION.AL:PERIOD. APPLICANT: LENNAR I lONIES,LLC;.(HEREINAFTER EIS, 10481 SIX MILE CYPRESS PARKWAY FORT l-MYER.S, FLORIDA 33966 BENEFICIARY: BOARD OF COUNTY COMM ISSIONERS:'('£}I,[:1FR COUNTY.FLORIDA (HEREINAF"I'ER"BENEFICIARY') 3299"TAMI ANIF TRAIL EAST,SUITE 303 NAPLES,FL 34112 An 4C?UNT: UP [0 AN AGGREGATE AMOUNT OF $2,316,333.00 (TWO MILLION Ti IRE E HUNDRED SIXTEEN THOUSAND THREE HUNDRED THIRTY THREE AND 00/10(T US DOLEARS) RL,. ERE�VISO BAY FRI LLA FIRENZE F) CRE1.)II AVAILABLE; ISSUER BY: PA.Y'NIEN•I AGAINST DOCUMENTS DETAILED HEREIN AND BENEFICIARY'S DRAFTS AT SIGHT DRAWN ON TFlE ISSUER.. • DOCUMENTS REQUIRED: At AII.,AB1.E. BY BENEFICIARY'S DRAFT-CS) AT SIGHT DRAWN ON THE ISSUER. AND PRESENTEE)AT PLACE Of EXPIRY ACCOMPANIED BY BI:N,EFIC1ARY'S STATEMENT PURPORTEDLY EDLY AEANI. ALLY SIGNF,[)AND DATED BY THE COUNTY MANAGE&CERTIFYING`['HAT A. (I) "DEVELOPER [-LAS FAII..E1.) TO COMPLETE,THE SUBDIVISION INI.I'ROVEMII.''IS FOR TREVISO BAY BELL A FIRENZE (PARCEL F) ACCORDING TO THE ENGINEER'S OPINION OF `PROBABLE CONSTRUCTION COSTS SUMMARY BELL " FIRENZE DATED FEBRUARY 2013 PREPARED 'B BY ' S`[".'.N IEC' (THE. ' I?S'I'IM'MA"IF') AND AS REQUIRED BY COLLIER COUNTY ORDINANCES ANT) RESOLUTIONS IONS '(TI[E "LAND DEVELOPMENT RECit)I°ATIONS'"); (11;). 'DF,A'EI.OPER. HAS BEEN 'ARI`I'TEN NOVICE DES( RIBIfNGi THE "EVENT`()R I OIVD[I0"1\"OF SUCH DEI'A I?1.:T TN REASONAB1...F 1)ET AIE,TSY CERTIFIED MAIL,REFURN RLCEIPI'REQ1..1ESTED, AND(III) DIE DI(I'ALiLTI I1AS"NO'!'BEEN CURED<WI["HIN THE CURE PERIOD PROVIDED FOR THEREIN IF ANY."; t)1R B. "A FINAL INSPECTION OF'I'HE SUBDIVISION IN'1PR(OVEMl✓NTS FOR IREVIS0 BAY BEI,LA Ell ENLE (PARCEL F) AS REQUIRED BY COF..L.IER COUNTY ORDINANCES AND R:ESOLL,TIONS ((THE `LAND T)EVEE;OPMEN'I'REGt 1:ATlON;S"I SATISFACTORY TO COLLIER COUNTY HAS NOT BEEN PERFORMED PRIOR T') TEiI' DATE_OF EXPIRY'', AND A.SAT[SFAC,"TORY Al.,:rERNA`['IL'E PE1.1-'1)RM.A.NCF::SE.CTURITY HAS NOT BEEN PROVIDED TO AND ACCEPTED BY THE BENEFICIARY.— 16 A4 i FIDELITY GUARANTY AND ACCEPTANCE CORP . 700 NW 107 AVENUE SIJITE 240 M I . . 3 , .M r 1 ' 2 THIS IS AN INTEGRAL PART OF LETTER OE CREDIT NO.FC;AC-I3CT±4? PACE'? DIZ1t'I S) DRAWI DRAW UNDER THIS I.,EITER. OE CREDIT SHALL BE MARKED: `''DR A�YN UNDER FIDELITY GUARANI \.,) r\.CCEPTANCE CORP C`REDTI NO FOAL I"3t){):. D,TIED 1LUNi 5 —_)I3 AND Y (.,S,I BE ACCOMPANIED F3 T TIT'S OR(ruN AI,LETTER OF CREOF I AND ALL ORIG'\A1..1t\TENI)\1E',I S,II A\'',r()TT. PROPER E`dDORSESIE N I. THIS I ETI`ER OF CREDIT SF.-'..I'S FO.)R t I I IN FULL THE 'TER\IS OF THE ISSUER S UNDERTAKING, SAND St.:t'IT IrNDE! 1'AKIN(i SHALL. NOT IN ANY WAY BE MODIFIED. AMENDED. OR AMPLIFIED BY REFERENCE TO ANY DOCUMENT,NT, INS1RI. MME'S F,OR ACiREEMEN"F REFERENCED CO HEREIN OR.N WHICH THIS 1.t°>T'[`f;R OF `RELIT RE AI'.ES, ANI) ANY ,SLC FI REFERENCE SHALL NOT'FI1'. DEEMED TO INC C)1 PO1 ATE HEREIN BY II EICENC,.F ANY DOCIF) 't'.NT, S•1'RI.;A{1.1.N'I'OR AGREEMEN'. ISSUER IIERE;E3 r I:INC \GESWI'T I I. BENEFICIARY THAT DID AF HT` 1 DRAWN UNDER AND IN CC) TL.(Ai",,CI: K'ITH, WE TERMS AND CONDITIONS OF CIIIS CREDIT WILT; BE DULY HONOREE) 13Y ISSUER IF f'RFSF'NTED \A.11THIN (f-'P ;%\T..IDITvY or THIS ( RIDII" TOGE•TI3tR t,'vil•IEE THI 1.)0C:IM[NTS ICEQT,;IRED T IER.EIN Al THE F�:,yCI,.OF EXPIRY PRIOR 1`O 4:00 P. I.EST.ON OR PRIOR 1 O TI 1E DATE OF EXPIRY. - I S CREDIT IS A CI O 'T/-E UNIFORM STI`�A.MS AND PRACTICE FOR DO f 'v(;'�N` AE ('',R I DITS I�t) ! lR° , 1 CHAMBER OF COMMERCE PURE Tr"'ATTL)N NO. (0)0." FIDELITY G(;_:1R 1 Fl 1N 1C{,ET'"1 A vC.F CORP. --())'14^t4"11.°'''''' DIA1v s BESSEI IL, I REAS('RhR:_ m Mwe 1 6 A 4 , 1 PPL-PL20120002425 REV: 1 BELLA FIRENZE DATE 2/19/13 COMPANION TO FP-PL20130000317 Stantec Bella Firenze February 2013 Engineer's Opinion of Probable Construction Costs SUMMARY Earthwork $ 637,550 Paving $ 360,409 Drainage $ 149,104 Sanitary Sewer $ 328,273 Potable Water $ 134,086 Irrigation $ 91,855 Landscape $ 52,246 Lighting $ 40,000 Erosion Control $ 37,571 Sub Total: $ 1,831,093 15%Contingency $ 274,664 Grand Total: 1 2,105,757 li: No. lui 77 '71 °;fi t .-- 1 i 2 if"1 ,---s-Z1111,5 ....,, ... son: _ 6n, pEQ:7,4", 1''') Stantec A ktex'52FeltiicTidt? /'"N STANTEC CONSULTING SERVICES,INC. /"..• 16 A 4 Bella Firenze OPC for Construction Earthwork Estimated Description Quantity Unit Unit Price Amount Lake Excavation 160,544 CY $ 1.90 $ 305,033.60 Rock Excavation-Lakes 5 AC $ 46,500.00 $ 232,500.00 Rock Excavation-Utilities 2,761 LF $ 24.15 $ 66,678.15 Rough Grading(Road,building slabs,swale,etc.) 106,749 SY $ 0.15 $ 16,012.33 Final Grading(Open Space) 45,606 SY $ 0.20 $ 9,121.22 Littoral Zone Gradin. 20,511 SF $ 0.40 $ 8,204.40 Earthwork Total $ 637,549.71 ' hTANTEC CONSULTING SERVICES,INCA 16 4 Bella Firenze /l OPC for Construction Paving Estimated Description Quantity Unit Unit Price Amount ROADWAY 3/4"Asphaltic Concrete,Type S-III (first lift) 9,307 SY $ 4.25 $ 39,554.75 3/4"Asphaltic Concrete,Type S-III (second lift) 9,307 SY $ 4.25 $ 39,554.75 6" Limerock Base(compacted&primed) 11,188 SY $ 6.85 $ 76,637.80 12"Stabilized Subgrade(compacted) 11,562 SY $ 2.15 $ 24,858.30 SIDEWALK 4" Limerock Base 3,511 SY $ 4.50 $ 15,799.50 4"Thick Reinforced Concrete Sidewalk 3,511 SY $ 24.75 $ 86,897.25 MISCELLANEOUS Curb Removal 1 LS $ 1,000.00 $ 1,000.00 Saw-Cut and Connect to Ex. Pavement 1 LS $ 300.00 $ 300.00 Type"F"Curb and Gutter 524 LF $ 13.70 $ 7,178.80 Type"A"Curb 407 LF $ 12.65 $ 5,148.55 Valley Gutter 5,912 LF $ 8.53 $ 50,429.36 Transition Curb 42 LF $ 10.00 $ 420.00 ADA Curb Ramps 6 EA $ 1,250.00 $ 7,500.00 Blue-Blue Reflector 8 EA $ 16.20 $ 129.60 Signing and Striping 1 LS $ 5,000.00 $ 5,000.00 Paving Total $ 360,408.66 ' ^TANTEC CONSULTING SERVICES, INC•-■ 16 A 4 4 Bella Firenze OPC for Construction Drainage Estimated Description Quantity Unit Unit Price Amount 12"ADS 1,790 LF $ 16.21 $ 29,015.90 15" RCP 200 LF $ 25.52 $ 5,104.00 18" RCP 600 LF $ 29.49 $ 17,694.00 24" RCP 600 LF $ 39.64 $ 23,784.00 30" RCP 130 LF $ 55.05 $ 7,156.50 36" RCP 82 LF $ 71.58 $ 5,869.56 18"Headwall 6 EA $ 1,723.80 $ 10,342.80 24" Headwall 2 EA $ 1,916.02 $ 3,832.04 36" Headwall 1 EA $ 2,100.00 $ 2,100.00 Yard drain 20 EA $ 400.00 $ 8,000.00 Grate Inlet 1 EA $ 2,476.46 $ 2,476.46 Valley Gutter Inlet 12 EA $ 1,723.80 $ 20,685.60 Throat Inlet 2 EA $ 2,771.39 $ 5,542.78 Junction Box 2 EA $ 3,000.00 $ 6,000.00 Core ex.C.S.for 30" RCP 1 EA $ 1,500.00 $ 1,500.00 Drainage Total $ 149,103.64 ' -6TANTEC CONSULTING SERVICES, INQ-. 5 Bella Firenze 16 A 4 OPC for Construction Sanitary Sewer Estimated Description Quantity Unit Unit Price Amount Single Sanitary Sewer Service 7 EA $ 775.00 $ 5,425.00 Double Sanitary Sewer Service 24 EA $ 850.00 $ 20,400.00 8" PVC Sanitary Sewer(SDR 26) (0'-6'cut) 1,689 LF $ 24.06 $ 40,637.34 8" PVC Sanitary Sewer(SDR 26) (6' -8'cut) 314 LF $ 32.56 $ 10,223.84 8" PVC Sanitary Sewer(SDR 26) (8'- 10'cut) 438 LF $ 27.04 $ 11,843.52 8" PVC Sanitary Sewer(SDR 26) (10'- 12'cut) 323 LF $ 33.17 $ 10,713.91 Manhole, 4' Diameter (0'-6'cut) 10 EA $ 4,668.22 $ 46,682.20 Manhole, 4'Diameter (6'-8'cut) 1 EA $ 5,809.32 $ 5,809.32 Manhole,4' Diameter (8'- 10'cut) 2 EA $ 5,797.59 $ 11,595.18 Manhole, 4' Diameter (10' - 12'cut) 3 EA $ 6,435.27 $ 19,305.81 Connect to existing force main 1 EA $ 1,500.00 $ 1,500.00 4"Force Main 188 LF $ 14.32 $ 2,692.16 Force Main Air Release Valve 1 EA $ 2,600.00 $ 2,600.00 Pump Station 1 EA $ 130,000.00 $ 130,000.00 TV Sewer w/mandrel (preliminary) 2,764 LF $ 1.60 $ 4,422.40 TV Sewer w/mandrel (final) 2,764 LF $ 1.60 $ 4,422.40 Sanitary Sewer Total $ 328,273.08 ' ,-ATANTEC CONSULTING SERVICES,INO•-■ 6 Bella Firenze OPC for Construction � � A H Potable Water 4 Estimated Description Quantity Unit Unit Price Amount Connect to Existing 8"Water Main with Gap Configuration 2 EA $ 1,500.00 $ 3,000.00 Single Water Service 7 EA $ 500.00 $ 3,500.00 Double Water Service 24 EA $ 800.00 $ 19,200.00 6" PVC Water Main (C-900, CL-200) 40 LF $ 16.16 $ 646.40 8" PVC Water Main (C-900,CL-150) 3,176 LF $ 18.87 $ 59,931.12 8" PVC Water Main (C-900, CL-200) 80 LF $ 20.89 $ 1,671.20 Fire Hydrant Assembly, Complete 8 EA $ 3,361.20 $ 26,889.60 Permanent Bacterial Sample Point 1 EA $ 1,197.94 $ 1,197.94 8"Gate Valve 5 EA $ 1,690.00 $ 8,450.00 Automatic Flushing Device w/Gate Valve 1 EA $ 4,850.00 $ 4,850.00 4"3M Magnetic Ball Markers Allowance (Every 200 LF and at Each Pipe Elbow Location) 35 EA $ 100.00 $ 3,500.00 Chlorination&Testing 1 EA $ 1,250.00 $ 1,250.00 Potable Water Total $ 134,086.26 ,-STANTEC CONSULTING SERVICES, INC• 7 Bella Firenze OPC for Construction Irrigation 16 A 4 Estimated Description Quantity Unit Unit Price Amount Connect to Existing Irrigation main 1 EA $ 1,500.00 $ 1,500.00 Single Irrigation Service 7 EA $ 500.00 $ 3,500.00 Double Irrigation Service 24 EA $ 800.00 $ 19,200.00 6" PVC Irrigation Main 605 LF $ 16.16 $ 9,776.80 8" PVC Irrigation Main 2629 LF $ 18.87 $ 49,609.23 6" Gate Valve 1 EA $ 1,509.00 $ 1,509.00 8"Gate Valve 4 EA $ 1,690.00 $ 6,760.00 Irrigation Total $ 91,855.03 ,TANTEC CONSULTING SERVICES,INCA 8 Bella Firenze OPC for Construction 16 A Landscape 4 Estimated Description Quantity Unit Unit Price Amount GENERAL LANDSCAPE Cocoplum -3 gal 604 EA $ 12.00 $ 7,248.00 Bahia Sod for Lake Bank(Lake Maintenance Easement) 68,000 SF $ 0.20 $ 13,600.00 Pine Straw Bale 605 EA $ 10.00 $ 6,050.00 Littoral Plants 2,625 EA $ 4.00 $ 10,500.00 Preserve Buffer Plants 3,712 EA $ 4.00 $ 14,848.00 Landscape Total $ 52,246.00 rATANTEC CONSULTING SERVICES, INS 9 Bella Firenze OPC for Construction Lighting 16 A 4 Estimated Description Quantity Unit Unit Price Amount Lighting Allowance 1 LS $ 40,000.00 $ 40,000.00 Lighting Total $ 40,000.00 • • • ,CTANTEC CONSULTING SERVICES, INQ^. 10 Bella Firenze OPC for Construction 16 A4 Erosion Control Estimated Description Quantity Unit Unit Price Amount Silt Fence 6,946 LF $ 1.30 $ 9,029.80 Turbidity Barrier 2,429 LF $ 11.75 $ 28,540.75 Erosion Control Total $ 37,570.55 1 6 A 4 4 Stantec Bella Firenze February 2013 Engineer's Opinion of Probable Construction Costs SUMMARY Earthwork 1 637,550 Paving $ 360,409 Drainage 149,104 Sanitary Sewer $ 328,273 Potable Water $ 134,086 irrigation 91,855 Landscape 1 52,246 Lighting 40,000 Erosion Control 37,571 Sub Total: 1,831,093 15%Contingency 274,664 'Grand Total: I 2,105,757 110%Bond Amount $ 2,3 .,333000t11417410, ..zzke.. •- • . ;Ct;\7,2--, 41:41;f:10,-----,:. NMI 417Sw4ns411,PE icense Eistr B)177 Writec Nipprbiationfig.i7013 '• %/6191.641A.CC)..,"