Loading...
Agenda 01/10/2017 Item #16A13 16.A.13 01/10/2017 EXECUTIVE SUMMARY Recommendation to approve a proposal from Humiston & Moore Engineers for Collier County Beaches and Inlets Annual Monitoring for 2017 under Contract No. 15-6382, authorize the County Manager or his designee to execute the work order for a not to exceed amount of $182,840 and make a finding that this expenditure promotes tourism. OBJECTIVE: To move forward with the annual required beach and inlet monitoring surveys and reports for Collier County Beaches and Inlets for 2017. CONSIDERATIONS: The Coastal Zone Management (CZM) section is tasked with the maintenance and monitoring of over thirty (30) miles of coastline, beaches, estuaries, channels, and bays. CZM has specific goals, objectives, and criteria to meet as identified within the Collier County Growth Management Plan, Land Development Code, and the Code of Laws and Ordinances regarding the county's coastal aquatic resources. In order to meet these goals and objectives, CZM has been charged with a variety of programs including the implementation of beach renourishment and dredging projects, the artificial reef program, derelict vessel program, waterways marker program, as well as any related operations that are required to maintain the health, aesthetics, and safety of the county's coastal waterways and communities. Yearly physical monitoring of the beaches and inlets is required by Florida Department of Environmental Protection (FDEP) permit. Results of this report are used to evaluate, recommend and prioritize annual beach segment renourishment. FISCAL IMPACT: Funds have been budgeted and approved for this activity in Fiscal Year 2017 in Tourist Development Tax Fund 195, Project No. 90536, County/Naples Beach. FDEP cost share funding may be requested at a future date to reimburse Collier County for a portion of the completed work. GROWTH MANAGEMENT IMPACT: There is no growth management impact associated with this Executive Summary. ADVISORY COMMITTEE RECOMMENDATIONS: Florida Department of Environmental Protection's (FDEP) permit requires Beach and Inlet Monitoring to be completed in January/February of each year. The 2016 Beach Renourishment project was completed in December 2016 and the as-built survey and annual monitoring survey will be combined into one monitoring event. Time is of the essence in completing this work since this monitoring event will also be used to determine if the Naples beaches will be renourished in 2017. At the December 8, 2016, Coastal Advisory Committee (CAC) meeting, this item was unanimously recommended for approval by a 7 to 0 vote. The Tourist Development Council (TDC) has approved this activity for budgeting purposes. An after- the-fact approval will be submitted to the TDC on January 23, 2017, as there was no TDC meeting in Packet Pg.490 16A13 01/10/2017 December. LEGAL CONSIDERATIONS: This item is approved as to form and legality and requires majority vote for approval. -CMG RECOMMENDATION: To approve a proposal from Humiston & Moore Engineers for Collier County Beaches and Inlets Annual Monitoring for 2017 under Contract No. 15-6382, authorize the County Manager or his designee to execute the work order for a not to exceed amount of$182,840 and make a finding that this expenditure promotes tourism. Prepared By: J. Gary McAlpin, P.E., Coastal Zone Management, Capital Project Planning, Impact Fees and Program Management Division, Growth Management Department ATTACHMENT(S) 1. Monitoring Proposal (PDF) 2.Work Order (PDF) Packet Pg 491 16.A.13 01/10/2017 COLLIER COUNTY Board of County Commissioners Item Number: 16.A.13 Item Summary: Recommendation to approve a proposal from Humiston & Moore Engineers for Collier County Beaches and Inlets Annual Monitoring for 2017 under Contract No. 15-6382, authorize the County Manager or his designee to execute the work order for a not to exceed amount of $182,840 and make a finding that this expenditure promotes tourism. Meeting Date: 01/10/2017 Prepared by: Title: Accountant—Capital Project Planning, Impact Fees, and Program Management Name: Gail Hambright 12/07/2016 2:59 PM Submitted by: Title: Division Director- IF, CPP &PM—Capital Project Planning, Impact Fees, and Program Management Name: Amy Patterson 12/07/2016 2:59 PM Approved By: Review: Procurement Services Lissett DeLaRosa Level 1 Purchasing Gatekeeper Completed 12/08/2016 12:55 PM Growth Management Department Judy Puig Level 1 Division Reviewer Completed 12/08/2016 2:14 PM Procurement Services Ted Coyman Additional Reviewer Completed 12/12/2016 2:24 PM Zoning Gary McAlpin Additional Reviewer Completed 12/12/2016 3:24 PM Procurement Services Adam Northrup Additional Reviewer Completed 12/13/2016 2:05 PM Capital Project Planning, Impact Fees,and Program Management Tara Castillo Additional Reviewer Completed Procurement Services Allison Kearns Additional Reviewer Completed 12/13/2016 2:58 PM Capital Project Planning,Impact Fees,and Program Management Amy Patterson Additional Reviewer Completed County Attorney's Office Colleen Greene Level 2 Attorney Review Completed 12/16/2016 4:41 PM Growth Management Department Jeanne Marcella Level 2 Division Administrator Completed 12/19/2016 11:18 AM Grants Edmond Kushi Level 2 Grants Review Completed 12/19/2016 1:50 PM Office of Management and Budget Valerie Fleming Level 3 OMB Gatekeeper Review Completed 12/20/2016 8:24 AM County Attorney's Office Jeffrey A.Klatzkow Level 3 County Attorney's Office Review Completed 12/20/2016 11:11 AM Budget and Management Office Ed Finn Additional Reviewer Completed 12/20/2016 3:09 PM Grants Therese Stanley Additional Reviewer Completed 12/29/2016 10:35 AM County Manager's Office Nick Casalanguida Level 4 County Manager Review Completed 12/30/2016 10:30 AM Packet Pg.492 16.A.13 01/10/2017 Board of County Commissioners MaryJo Brock Meeting Pending 01/10/2017 9:00 AM Packet Pg. 493 (1 (Li.oZ JoJ 6utao;luoJ ienuuy slalul ,g goee : E9I' ) lesodoid 6upo}iuow :}uawgoefy r) rn NI- 7° HUMISTON °' a ti ' L.'i & MOORE k ,�', ENGINEERS co s h t COASTAL 5679 STRAND COURT d ENGINEERING DESIGN NAPLES,FLORIDA 34110 FAX 239 594 2025 ,,,, , .,. ,, ,,,4 AND PERMITTING PHONE:239 594 2021 December 6, 2016 Mr. Gary McAlpin Coastal Zone Management Collier County Government 2800 N. Horseshoe Drive Naples, FL 34104 Re: Proposal for Collier County Beaches and Inlets Annual Monitoring for 2017 Collier County Contract 15-6382; HM File No 23-065.2017Beach-Monitor Dear Gary: Enclosed is a proposal for the Collier County Beaches and Inlets monitoring surveys and monitoring reports for 2017. Cost breakdown as shown 54% H&M and 46% sub-consultant. All surveys are to be conducted in within 90 days of the Notice to Proceed date and the completion date for all work is estimated to be 240 days from the date of the Notice to Proceed. Rectified aerial images acquired for 2017, provided by the Collier County Property Appraiser's Office, are to be submitted to the DEP as part of the work described below for all projects. Task 1 Collier Beach-Scope of Work and Budget Conduct the annual monitoring survey for Collier Beach Nourishment Project consistent with the monitoring plan approved by the Department of Environmental Protection (DEP). This scope of work consists of DEP monuments R-17 to R-84 and R-58A. (69 profiles). One report will be issued to the County for the preliminary assessment of beach fill needs for Collier County Beaches per the Design Standard beach width, established prior to the 2006 project, and the second report is to be submitted to the DEP in compliance with the annual monitoring. Task la. Sub Total Data Collection Budget (SDI) $ 47,780* LS Task lb Preliminary Report (H&M) $ 12,000 TM Task lc Final Report (H&M) $ 20,000 TM Total Task 1 Subtotal (SDI + H&M) $ 79,780 *Includes beach profiles R-10 through R-21 with half monuments, R-58+300, R-60+518, R-61+408, and R-61+816 for a total of 90 profiles. 6u!Jo;luolAl lenuuy s;alul 1oea8 £9n) lesodoid 6uuo;luoIN :;uewq{oe;;y rn a .r d Task 2 Wiggins Pass Inlet-Scope of Work and Budget a Conduct the annual monitoring survey for Wiggins Pass Navigation Channel Expansion Maintenance Dredging Project consistent with the monitoring plan approved by the DEP. This scope of work consists of DEP monuments R-10 to R-22 including half monuments, the MHWL from R-17 NE for a minimum of 1500 feet. Stations -2+00 to 15+00 (from R-15 to R-18.5) and the navigation channel with grid lines 100 feet apart (C-3 thru C-34, CN-35 thru CN37), One report will be issued to the County for the preliminary assessment of dredging needs for the Wiggins Pass Inlet and the second report is to be submitted to the DEP in compliance with the annual monitoring. Task 2a. Sub Total Data Collection Budget (SDI) $ 10,325 LS Task 2b Preliminary Report (H&M) $ 8,000 TM Task 2c Final Report (H&M) $ 15,000 TM Total Task 2 Subtotal (SDI + H&M) $ 33,325 Task 3 Doctors Pass Inlet-Scope of Work and Budget Conduct the annual monitoring survey for Doctors Pass Maintenance Dredging project consistent with the monitoring plan approved by the DEP. This scope of work consists of 77 Dredge Template Profiles and 12 beach profiles R-58A, R-58, R-584-300, R-59, R-60, R-60+518, R- 61, R-61+408, R-61+816, R-62, R-63, and R-64. One report will be issued to the County for the preliminary assessment of dredging needs for Doctors Pass Inlet and the second report is to be submitted to the DEP in compliance with the annual monitoring. Task 3a. Sub Total Data Collection Budget (SDI) $ 7,420 LS Task 3b Preliminary Report (H&M) $ 6,000 TM Task 3c Final Report (H&M) $ 12,000 TM Total Task 3 Subtotal (SDI + H&M) $ 25,420 Task 4 South Marco Beach- Scope of Work and Budget Conduct the annual monitoring survey for South Marco Beach Nourishment Project consistent with the monitoring plan approved by the DEP. This scope of work consists of DEP monuments R-139 to R-148, G-1 thru G-5, and K-1 thru K-2. A report is to be submitted to DEP. Task 4a. Sub Total Data Collection Budget (SDI) $ 10,660 LS Task 4b Final Report (H&M) $ 10,000 TM Total Task 4 Subtotal (SDI + H&M) $ 20,660 cs (LI.OZ aoj 6uuopuow ienuuy slalul 'g 4oe38 : £9n) lesodoid 6ulao;luoIl :;uauagaefl co ri rn 6 a d Task 5 The Entrance to Collier Bay-Scope of Work and Budget Conduct the annual monitoring survey for the Collier Bay Entrance Channel Dredging Project to °' be consistent with the monitoring plan approved by the DEP as described in the permit. This scope of work consists of (10) Hideaway Beach Profiles: 54+57, 55+16, H-12, 57+08, H-13, 62+66, 63+66, H-14, H-15 & H-16; and (13) Channel profiles: Cl, C2, C3, C3.5, H16 (AZ 47.51), C4, C5, C6, C7, C8, C9, C10, C11. A report is to be submitted to the County. Task 5a. Sub Total Data Collection Budget (SDI) $ 8,655 LS Task 5b Final Report (H&M) $ 15,000 TM Total Task 5 Subtotal (SDI + H&M) $ 23,655 Grand Total (SDI + H&M) $ 182,840 Tasks 1 thru 5 Tasks will be billed on a time and materials basis, unless otherwise noted. The budgets for these tasks may therefore be considered as not-to-exceed amounts with the understanding that in the event regulatory requirements or requests from County staff result in Additional Services exceeding the estimated budget amounts, a budget amendment will be requested. Please call if you have any questions. Sincerely yours, HUMISTON & MOORE ENGINEERS Brett D. Moore, P.E. President (L60Zaoj 6UuOppuoAJ lenuuy s;eiul '8 yoea8 lesodoid 6upo;iuoW :;uauayoe;;y M 0) r d' Sea Diversified, Inc. a 41:7s ETA 21 N.W. 2714 Street 1900 S. Harbor City Blvd, Ste 110 Delray Beach, Florida 33444 Melbourne, Florida 32901 05 Phone: 561-243-4920 Phone: 321-984-7268 a ;; r I Facsimile: 561-243-4957 Facsimile: 321-984-7270 December 5, 2016 Mr. Steve Foge, P.E. sent via electronic mail 12/05/16 Humiston & Moore Engineers (sf(humistonandmoore.com) 5679 Strand Court Suite 110 Naples, Florida 34110 Re: Proposal for Professional Services - Rev.1 Collier County 2017 Physical Monitoring Survey Collier Beach, Wiggins Pass, Doctors Pass, South Marco Beach and Entrance to Collier Bay Collier County, Florida Sea Diversified P.N. 16-2500 Dear Mr. Foge: In accordance with your request, Sea Diversified, Inc. (SDI) is pleased to submit the following revised proposal for professional services. The scope of work shall include onshore/offshore beach profile surveys, including hydrographic surveys of channels and borrow areas, at Collier Beach, Wiggins Pass, Doctors Pass, South Marco Island and the entrance to Collier Bay project areas. In accordance with your latest summary of scope provided on November 30, 2016, the 2017 survey effort shall encompass the following: Task One: Beach and Offshore Profiles (Collier, Wiggins Pass and Doctors Pass) 1. Beach profiles at R-10 to R-84, including intermediate profiles R-10.5, R-11.5, R-12.5, R-13.5, R-14.5, R-15.5, R-17.5, R-18.5, R-19.5, R-20.5, R-58A, R-58+300, R-60+518, R-61+408, R- 61+816, totaling 90 profiles. Task Two: Wiggins Pass: 1. Entrance channel, Stations -2+00 to 15+00 (R-15 to R-18.5), totaling 18 transects. 2. Internal channels C-3 through C-34, CN-35, CN-36 and CN-37, totaling 35 transects. 3. MHWL from R-17 to the NE 1500 feet on the south side of the inlet. 4. MHWL from R-16 to the east 1500 feet on the north side of the inlet. Task Three: Doctors Pass: 1. Dredge template profiles, totaling 77 profiles. Task Four: South Marco Beach: 1. Beach profiles at R-139 to R-148, G-1 to G-5, K-1 to K-2, totaling 17 profiles. 2. Borrow Area not included. Task Five: Entrance to Collier Bay: 1. Hideaway Beach Profiles: 54+57, 55+16, H-12, 57+08, H-13, 62+66, 63+66, H-14, H-15 and H- 16, totaling 10 profiles. 2. Channel transects: Cl, C2, C3, C3.5, H-16 (AZ 47.51), C4, C5, C6, C7, C8, C9, C10, C11, totaling 13 transects. C3 to C5 includes upland beach profile data collection. General: SDI shall provide supervision, field / office support staff and equipment to perform the scope of work described, herewith. All work shall be conducted to the highest level of industry standards and under the responsible charge of a Professional Surveyor and Mapper registered in the State of Florida. All work shall meet or exceed the Standards of Practice set forth by the Florida Board of Professional Surveyors and Mappers in Chapter 5J-17, Florida Administrative Code, pursuant to Section 472.027, Florida Statutes, and in compliance with the Bureau of Beaches and Coastal Systems Monitoring Surveying Engineering Applicati©ns ca (LIOZ aol 6upolmoiAT ienuuy slam 'g yoeae. : £gt7Z) lesodoid 6upol!uoI :}uauayoellyco ch oo r � Collier County 2017 Physical Monitoring Survey('VEzet Collier Beach, Wiggins Pass, Doctors Pass, South Marco Beach and Entrance to Collier Bay Collier County, Florida a December 5, 2016 (Original December 1, 2016) Page 2 of 3 Standards for Beach Erosion Control Projects, Sections 01000 and 01100 (Updated October 2014). If time permits, deviations from the scope of work shall be addressed via formal approved addendum to the executed Agreement for Professional Services. Horizontal and Vertical Data: Horizontal Datum: Feet, relative to the Florida State Plane Coordinate System, East Zone, North American Datum of 1983 (NAD83) Vertical Datum: Feet, relative to North American Vertical Datum of 1988 (NAVD88) or datum as required by Client Horizontal / Vertical Control Verification SDI will verify the horizontal and vertical position of all found and used monuments for the survey. Horizontal and vertical positions will be verified via Real-Time Kinematic GPS procedures. In the event vertical obstructions prohibit the use of GPS, conventional methodologies will be employed. Temporary control points (TBM's) will be set in the event a monument cannot be readily found. As practical, the TBM will be set at the reference monument location. If the specified location is not practical, the TBM will be set at a more suitable location either landward or seaward along the specified profile azimuth. H&M shall be notified of any missing monuments and shall be provided with the horizontal and vertical position of all TBM's. Onshore Profile Data Collection - Topographic Onshore profile data collection shall extend from the FDEP profile control monument seaward to approximate wading depth or as required to overlap the offshore profile data a minimum distance of fifty (50) feet. Profile data collection shall extend landward to the seawalls or fifty (50) feet landward of the five-foot (+5.0') NAVD contour line. In the event there is a physical barrier on line between the beach and the monument, every reasonable attempt shall be made to extend the survey beyond the barrier to the reference monument position. It is understood that certain physical barriers may be considered impassible such as large buildings, private residences with difficult access, waterbodies, mangroves or other heavy vegetation requiring line clearing. At the discretion of the surveyor, data collection will be terminated at the first physical barrier if deemed impassible using practical means of extending the survey landward. Profiles terminated due to impassible barriers will be noted in the field books. Profile data will be collected using either conventional differential leveling or Real-time Kinematic Differential Global Positioning techniques. Data points will be collected at a maximum interval of twenty-five (25) feet and at all grade breaks (exceeding six-inches) and material changes along the profile. In the event the profile control monument is located more than three hundred (300) feet landward of the vegetation line, data points shall be extended to intervals of one hundred (100) feet from two hundred (200) feet landward of the approximate vegetation line to the monument location. The reference monument shall be recorded as range 0.0 along the profile with positive ranges extending seaward of the monument and negative ranges extending landward of the monument. Offshore Profile Data Collection - Bathymetric Bathymetric profile data shall be collected as close to high tide as practical and shall extend landward to a depth that overlaps the onshore portion of the survey a minimum distance of fifty (50) feet. Bathymetric profile data collection shall extend seaward to the —13' NGVD29 contour (approximately - 14.5' NAVD88) at Collier Beach, South Marco Beach and Wiggins Pass, and negative —15' NGVD29 contour (approximately -16.3' NAVD88) at Doctors Pass, or two thousand (2000) feet from the shoreline, whichever is the greater distance. Bathymetric data collection shall occur as close to the time of the onshore topographic survey as practical, which shall not exceed seven (7) days of time difference between the two (2) survey events. Maximum wave height during the course of bathymetric data collection shall be three (3) feet. Surveying • Engineering • Applications ch (L 6o ao} 6uiao;(uow (enuuv s;eiu) 'g goea8 : £gpz) lesodoid 6uuo;(uoW :;uawgoe;;y Q «� Q) Collier County 2017 Physical Monitoring Survey n- Collier Beach, Wiggins Pass, Doctors Pass, South Marco Beach and Entrance to Collier Bay CSEA Collier County, Florida I- 11:,; December 5, 2016 (Original December 1,2016) Page 3 of 3 Bathymetric data shall be collected using an automated hydrographic system comprised of a survey launch equipped with a marine grade sounder, differential global positioning system and computer- based navigation / data collection system, and when deemed necessary may be interfaced with a DMS-05 Motion Sensor System. The motion sensor will be employed as necessary to reduce the effects of vessel heave, pitch and roll during the course of data collection. The sounder shall be calibrated via bar checks prior to the start of the survey. Prior to the start of the survey a tide staff or gauge will be established in proximity to the project for recording water levels during the course of the data collection activities. The tide staff or gauge will be set relative to published control in the vicinity of the project. Digital Ground Photography During the course of field data collection, digital photographs shall be taken at approximate mid- beach along each profile line. Three (3) photographs shall be captured, one each shore-parallel north and south of the profile and one towards the monument location. An additional photograph of the monument or TBM shall be taken with sufficient clarity to read the monument stamping. Digital images shall be provided to H&M on CD / DVD media in .jpg format at a minimum 640 x 480 resolution. Data Processing and Final Deliverables Upon completion of field survey activities, data will be edited and reduced to the project datum and translated to an x,y,z, ASCII format for submittal to H&M. H&M will be provided the following deliverables: 1. Survey report certified by a Professional Surveyor and Mapper. 2. Description of all monuments and TBM's used for the survey, including identification, stamping, coordinates, elevations and profile azimuths. Control description shall be provided in both hardcopy and digital formats (ASCII and Excel), as applicable. 3. Bathymetric data and / or profile data in ASCII x,y,z format 4. Digital photographs in .jpg format with appropriate labeling 5. Metadata files Cost Breakdown: Tasks One: Collier Beach (R-10 to R-84): $ 47,780.00 Tasks Two: Wiggins Pass: $ 10,325.00 Tasks Three: Doctors Pass: $ 7,420.00 Tasks Four: South Marco Beach: $ 10,660.00 Tasks Five: Entrance to Collier Bay: $ 8,655.00 Total: $ 84,840.00 Should you have questions or require additional information please do not hesitate to contact us at your convenience. We appreciate this opportunity to assist you with this project and look forward to hearing from you soon. Best Regards, r4 William T. Sadler Jr., P.S.M., P.E. President Sea Diversified, Inc. WTS/dq Surveying • Engineering Applications 03 (L40Z ao; 6uuo1luoLN lenuuv s;alui 'g yoeag : £9t7Z) lesodoid 6ulao;luow :;uauayoe;;V o ei 2017 'n Q Contract 13-6164 CZ a) coDate: December 6, 2016 a Estimated Summary d C) fa Collier County Beaches and Inlets Annual Monitoring a. SUMMARY BREAKDOWN BY TASK Task 1 Collier Beach 79,780.00 Task 2 Wiggins Pass 33,325.00 Task 3 Doctors Pass 25,420.00 Task 4 South Marco 20,660.00 Task 5 The entrance to Collier Bay 23,655.00 182,840.00 SUMMARY BREAKDOWN BY SUB-TASK Task la Collier Beach Data collection 47,780.00 LS Task 1b Preliminary Report 12,000.00 TM Task 1c Final Report 20,000.00 TM Task 2a Wiggins Pass Data collection 10,325.00 LS Task 2b Preliminary Report 8,000.00 TM Task 2c Final Report 15,000.00 TM Task 3a Doctors Pass Data Collection 7,420.00 LS Task 3b Preliminary Report 6,000.00 TM Task 3c Final Report 12,000.00 TM Task 4a South Marco Data Collection 10,660.00 LS Task 4b Final Report 10,000.00 TM Task 5a Entrance to Collier Bay Data Collection 8,655.00 LS Task 5b Final Report 15,000.00 TM 182,840.00 SUMMARY Sea Diversified Survey 84,840.00 LS PRN2 Principle Engineer 206 121 24,926.00 SEN Senior Engineer 157 0 0.00 PJTM Project Manager 147 0 0.00 SDS Engineer 123 391 48,093.00 SIN Senior Designer 114 0 0.00 SCI Designer 94 0 0.00 SRT Senior Technician 85 162 13,770.00 INS Inspector 76 0 0.00 TEC Technician 72 97 6,984.00 CAD Gadd Technician 81 0 0.00 Pad Clerical/Administrative 62 58 3,596.00 PLOTTING, BOND 25 0 0.00 PLOTTING, VELLUM 10 0 0.00 EXPENSE- mailings, 0 0 0.00 EXPENSE* 0, 0 631.00 98,000.00 TM *Expenses include printing, copies, etc. 182,840.00 11/0 LI 16.A.13.b /WORK ORUERIPt'RCIIASE ORDER Contract 15-6382 "C;rant Funded Professional Ser ices for Coastal tone.. Contract Expiration Date: June 8. 2017 I his Work Order is for professional Engineering. services for work known as: Project Name: Collier Count Beaches and Inlets Annual Monitoring for 2017 Project No: 90033 / the work is specified in the proposal dated December 6. 2016 which is attached hereto and made a part of this Work Order. In accordance with Terms and Conditions of the Agreement referenced above. this Work Order/Purchase Order is assiLined to: I lumiston & Moore Enuineers. csiScope of Work: As detailed in the attached proposal and the fi>llowlug: * Task la Sub Total Data Collection Budget (1)51) c * Task lb Preliminary Report (ULM) 2 * Task lc Final Report (H&.M V — * 'rusk 2a Sub Dotal Data Collection Budget (SDI) v * Task 2h Preliminary Report (H&M) . * Task 2c Final Report (H&M) a) * Task 3a Sub notal Data Collection Budget (SUI) ' c * lask 3h Preliminan Report (II&M)V 05 * Task 3c Final Report (I * 1 4a Sub dotal Data Collection Budget (SDI! * Task 4h Final Report (I1&M)✓ * rask 5a Sub notal Data Collection Budget (SUI) * 1 ask 5b Final Report (11&M) ✓ a� Schedule of Work_ Complete work within 240 dat,s from the date of the Notice to Proceed which is accompanying this Work Order. The Consultant agrees that an> Work Order that extends beyond the expiration date el Agreement No. 15-6382 will sury ire and remain subject to the terms and conditions of that Agreement until the completion or termination of this Work Order. Compensation: In accordance with the Agreement referenced above_ the Count} will compensate the Firm in accordance with followin<e method(s): 7 Negotitated Lump Sum (NI.S) 'Lump Sum Plus Reimbursable Costs (I.S•+ RC) H"I ime & Material ( I &M) (established hourfv rate Schedule B) I 1 C est Plus Fixed Fee (CIII).). (define which method dill he used for NAhich tasks) as provided in the attached proposal. cask la S 47.780.00 (ES) I ask 1b S 12.000.00 ( 1,01) l.ask Ic 5 '0.000.00 ( I&M) Task 2a S 10.325.00 (15) 1 ask 2b S 8.0f) .0)) ( l &M) 1 ask 2c S 15.000.00 ( I &M) Page I of 2 Packet Pg. 501 1 6.A.1 3.b "[ask 3a $ 7,420.00 (LS) Task 3h $ 6,000.00 (T&M)`" Task 3C $ 12,000.00 (T&M)`/ Task 4a $ 10,660,00 (LS)✓ Task 4b $ 10,000.00 (T&M)✓ Task Sa $ 8,655.00(LS) ✓ 'Task 5b $ 15,000.00("T&M)✓ TOTAL FEE $182,840.00 (I,S, T&M)`" 1240 ,,,,h. 0 PREPARED BY: ? I14f CNI J. Gary Mc. 1pin,C.7,M lanagerDate 42rn APPROVED ROVED BY: r_. t _.-- o �G � 7+iiiy'Patterson, Division Director Tate E �-,. t �4 a � APPROVI�I 'r'--:�� , '✓'. -- .` ``��---� _ _ Date c David S. Wilkison,Department Ilead c Q U) By the signature below, the Firm (including employees, officers and/or agents) certifies, and hereby a discloses,that, to the best of their knowledge and belief, all relevant facts concerning past,present, or 06 currently planned interest or activity (financial, contractual, organizational, or otherwise) which U relates to the proposed work; and hear on whether the Firm has a potential conflict have been fully ea m disclosed. 00 M Additionally, the Firm agrees to notify the Procurement Director, in writing within 48 hours of co learning of any actual or potential conflict of interest that arises during the Work Order and/or project duration. Cr) -o L 0 Y L ACCEPTED BY: I lumiston & Moore Engineers ° __ ai Mohamed A Dab es, PhD P.E. Vice President Date E 0 ac....1 Page 2 of 2 Packet Pg.502 -