Resolution 2011-122 RESOLUTION NO. 2011 - 122 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS EX-OFFICIO THE GOVERNING BOARD OF THE WATER-SEWER DISTRICT APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DISTRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; PROVIDING FOR ADELA YED EFFECTIVE DATE OF AUGUST 1, 2011 FOR THE MANUAL WHEREAS, on May 11, 2004, as Item 8 D. the Board of County Commissioners as the Ex Officio Governing Board of the Water-Sewer District (Board) concurrently adopted Collier County Ordinance No. 2004-31, entitled the Collier County Utilities Standards and Procedures Ordinance (the "Ordinance"), and the Collier County Water-Sewer District Utilities Standards Manual," (Manual), including all of the Manual's exhibits, and WHEREAS Ordinance No. 2004-31 is codified in Chapter 134, Article III of the Code of Laws and Ordinances; and WHEREAS, since the 2004 adoption of the Manual it has become necessary to make updates that reflect current standards in design and preparation of plans and specifications for all utilities construction projects; and WHEREAS, after input from stakeholders Public Utilities staff has recommended that the Board adopt this Resolution to approve amendments to the Manual as identified in Exhibit A; and WHEREAS, Section 134-61 of the Code of Laws and Ordinances requires the Manual to be amended by Resolution of the Board under the scheduled public hearings or the summary agenda section; and WHEREAS, it is in the interest of the health, safety, and welfare that this Resolution be adopted. NOW, THEREFORE, BE IT RESOLVED BY THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS EX-OFFICIO THE GOVERNING BOARD OF THE WATER-SEWER DISTRICT, that: The Collier County Water-Sewer District Utilities Standards Manual, as amended, as identified in Exhibit A, is hereby approved and shall take effect on the 151 day of August, 2011. This Resolution adopted after motion, second and majority vote, this ~ day of July, 2011. .' ...,e8 -UJD ...., , AT1:,ES;.;... ..11- " .b jIGHTE. .I3'R6~K, ERK.' . ~. ~\' 'f~..~"I,." ,\\'- r"<j('r I, ...' "'lit.".., "?iC' 'I, ,...'\. c.;~~.l ,.:; . ~. ~ /. .... BOARD OF COUNTY COMMISSION~f ,OF ..COLLIE~': COUNTY, FLORIDA, AS EX-OFFICIO.~fIeGOVERNlN'9:..', BOARD O~T E WATER-SEWER DIS"~T - : \~ . W ~ -::~,.. ./ .. :......~- . "". v . Y. ..-..... c..? . .. ("- . FRED W. COYLE CHA AN ,~;.;;~........::> ,,' , "I I;)". r ,-- " ;'IJ '" ., ,\\,\ 111/iltH'"'' r;-. -fJ--W ~ Jenni;UB. White Assistant County Attorney Table of Revisions Exhibit A COLLIER COUNTY UTILITIES STANDARDS MANUAL TABLE OF REVISIONS COLLIER COUNTY PUBLIC UTILITIES PLANNING AND PROJECT MANAGEMENT DEPARTMENT AS OF 07!2011 CHANGES TO UTILITIES Section Sub-Section! Detail # Revision Summary 1 1.4 Update meter requirements to only require leak detection meters on fire service lines. 3 W-8 Add detail, previously deleted, and update. 3 W-9 Uodate detail. 3 W-9A Update detail. 3 W-10 Delete detail. 3 W-11 Add detail, previously deleted, and update. 3 W-11 A Update detail. 3 W-15 Delete detail. 3 W-16 Add detail, previously deleted, and update. 4 Appendix G Uodate list. Page 1 of 1 Proposed Revision to Section 1. Desion Criteria Proposed additions in text are noted in bold, Proposed deletions in text are noted in strike through. Section 1, Design Criteria, Page 6, text revisions in 1.4 1.4 Fire Service Systems All private fire service systems for sprinkler systems, wet standpipe systems, and privately- owned or controlled distribution systems shall be metered with a Fire Service, line sizod, moter aM-shall be installed with an appropriate back flow prevention device with a leak detection meter. The meter shall be owned and maintained by the private service owner. The COUNTY requires all privately-owned backflow devices to be certified at the time of installation and on an annual basis by a Certified Back Flow Tester (University of Florida, TREEO Center, or equivalent certification program). The results shall be submitted to the County Manager or designee. The County Manager or designee will require all privately owned metering devices to be certified for accuracy at the time of installation. Fire meter deyices using a three quarter to two inch (%" to 2") metering device shall be re-calibrated to manufacturer's specifications every five (5) years, replaced every ten (10) years, or replaced immediately upon meter failure. Fire meter devices greater than two inches (2") shall be re-calibrated to manufacturer's specifications every five (5) years and replaced immediately upon meter failure. The County Manager or designee will inform the owner by mail prior to the due date. Private owner(s) shall submit certification results to the County Manager or designee within sixty (60) days of the due date, 1.4.1 Fire Service Meters for Residential Systems Residential projects such as, but not limited to, single family, multi-family condominiums, trailer parks, mobile home parks, etc. utilizing a master meter shall pass all fire flow through such meter. The meter shall be sized to pass the domestic coincident draft plus rated fire flow at the AVVWA pressure loss specifications. 1.4.2 Fire Service Meters for Commercial and Other Non-residential Systems Commercial projects such as, but not limited to, shopping centers, malls, retail, and industrial buildings shall pass all fire flow through a potable master meter or have a separate fire service connection to the water distribution main, The Fire Service meter and isolation valves shall be extended aboye final grade as shown in the Utilities Detail Drawings. For meter reading purposes, metering devices shall lie within a County Utility Easement (CUE) that shall be dedicated separately to the Board for the appropriate Water-Sewer District or in conjunction with the easements for anyon-site utility system(s). The Owner shall purchase and install an appro'/ed AMR meter and approved backflow devices with a leak detection meter at no expense to the appropriate Water-Sewer District. CONCRETE FOUNDATION FULL LENGTH OF ASSEMBLY (lYP) 4' WIDE, 6. THICK 6. x 6- lOx 1 0 WELDED WIRE MESH FLOW -- MIL POLY WRAP ONSTRUCTION GRADE SHEETING, DOUBLE LAYER, PLASTIC ALL PURPOSE FLOW CUSTOMER SERVICE LINE , I'. PROPERlY OWNER MAINTENANCE TO THIS POINT NOTES: 1. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERlY OWNER, STARTING AFTER THE INLlNE GATE YALVE AT THE PROPERlY LINE OR RIGHT-OF-WAY LINE. 2. COUNlY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INLlNE GATE YALVE FROM THE COUNlY'S WATER MAIN. 3. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROYED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNlY WATER DEPARTI.4ENT. 4. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPOXY PAINT. 3" AND SMALLER FIRE SYSTEM DETECTOR CHECK ASSEMBLY DETAIL NTS W-8 REVISED: JULY 2011 2" REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY SUPPLIED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS. UL/FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNlY ORDINANCE AND AWWA M-14. (SEE APPROVED BACKFLOW DEVICES. APPENDIX G) LOCK OS&Y VALVE CLOSED 2" CURB STOP 12" SPOOL PIECE WITH 2. TAP FIRE PROTECTION METER (SEE COUNlY APPROVED PRODUCT LIST. APPENDIX F) UL/FM APPROVED FOR FIRE SERVICE INSTALLATION (FACTORY ASSEMBLED WITH TOP ACCESS STRAINER ONLY) UL/FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNlY ORDINANCE AND AWWA M-14. (SEE APPROVED BACKFLOW DEVICES. APPENDIX G) RISING STEM AND RESILIENT SEAT FLANGED GATE YALVE (TYPICAL OF THREE) MJ 45' OR gO' BEND WITH RETAINER GLANDS MAIN SIZE PER UTILITY PLAN MAIN SIZE PER UTILITY PLAN NOTES: 1. ALL ABOVE GROUND PIPE SHALL BE FLANGED END DUCTILE IRON PIPE, PRESSURE ClASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL. 2. WATER MAIN EXTENSION AND ASSEMBLY IS REQUIRED TO BE FLUSHED, CHLORINATED AND GIVEN BACTERIAL CLEARANCE BY THE WATER DEPARTMENT LAB BEFORE PLACEMENT IN SERVICE. 3. BACKFLOW UNIT AND METER REQUIRES INITIAL CERTIFICATION FOR OPERATION AND ACCURACY WITH RESULTS AND ANNUAL TESTS SUBMITTED TO THE COLLIER COUNTY WATER DEPARTMENT. 4. INSPECTIONS ARE REQUIRED FOR SYSTEM TIE-IN AND ASSEMBLY CONNECTION. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPOXY PAINT. 6. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. TEMPORARY BACKFLOW PREVENTER AND FIRE PROTECTION METER TIE-IN ASSEMBLY NTS W-9 REVISED: JULY 2011 UL/FM APPROVED fOR FIRE SERVICE INSTALLATION. INSTALlATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M-14. (SEE APPROVED BACKFLOW DEVICES APPENDIX G) . RISING STEM AND RESIUENT SEAT FLANGED GATE VALVE (TYP) 2. REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY, SUPPUED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SIUCONE RUBBER SEALS UL/FM APPROVED fOR fiRE SERVICE INSTALlATION. INSTALLATION AS REQUIRED BY ORDINANCE AND AWWA M-14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) LOCK OS&Y VALVE CLOSED 2" TAP (TYPICAL Of 1W0) INSTALL INUNE GATE VALVE AT PROPERlY UNE OR RIGHT-Of-WAY UNE NOTES: YALVE SETTER (SEE COUNTY APPROVED PRODUCT UST, APPENDIX f) 1. ALL ABOYE GROUND PIPE SHALL BE FLANGED END DUCTILE IRON PIPE, PRESSURE ClASS 350. ALL NUTS AND BOLTS SHAL BE STAINLESS STEEL. 2. WATER MAIN EXTENSION AND ASSEMBLY IS REQUIRED TO BE FLUSHED, CHLORINATED AND GIVEN BACTERIAL CLEARANCE BY THE WATER DEPARTMENT LAB BEFORE PLACEMENT IN SERVICE. 3. BACKFLOW UNIT AND MITER REQUIRES INITIAL CERTIFICATION FOR OPERATION AND ACCURACY WITH RESULTS AND ANNUAL TESTS SUBMITTED TO THE COWER COUNTY WATER DEPARTMENT. 4. INSPECTIONS ARE REQUIRED FOR SYSTEM TIE-IN AND ASSEMBLY CONNECTION. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPOXY PAINT. 6. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. FIRE PROTECTION METER TIE-IN ASSEMBLY NTS REVISED: JULY 2011 MAIN SIZE PER UTIU1Y PLAN MJ 45' OR 90" BEND WITH MJ RETAINER GLANDS (lYP) NOTES: INSTALL INUNE GATE YALVE AT PROPERlY UNE OR RIGHT-OF-WAY UNE CONCRETE FOUNDATION (lYP) FULL LENGTH OF METER ASSEMBLY; 4' WIDE, 6- THICK REINFORCED 6 X 6 10/10 WELDED WIRE MESH FIRE PROTECTION METER (SEE COUNlY APPROVED PRODUCT UST, APPENDIX F) WITH BYPASS. UL/Fl.t APPROVED FOR FIRE SERVICE INSTALLATION (FACTORY ASSEMBLED) (WITH TOP ACCESS FACTORY APPUED FUSION BONDED EPOXY COATED STRAINER ONLY) AIR RELEASE VALVE (SEE COUNlY APPROVED PRODUCT UST, APPENDIX F) BRASS NIPPLE NSTALL INUNE GATE YALVE AT PROPERlY UNE OR RIGHT-OF-WAY UNE MAIN SIZE PER UTIU1Y PLAN 1. ALL ABOYE GROUND PIPE WILL HA SHALL BE STAINLESS STEEL. 2. (4) YEHICULAR GUARD POST DOCUMENTS SUBMITTED F R. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION 3. TIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL S. (SEE W-15) 4. PROPERlY OWNER, STARTING FROM THE FIRST ISOLATION YALVE PRIOR 5. OF THE MATERIAL UP TO AND PRIOR TO YALVE ON THE ASSEMBLY FROM THE COUNlY'S 6. I\L CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST COUNlY WATER DEPARTMENT. 7. ALL PLANTINGS SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPOXY PAINT. 9. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. 10. REFER TO APPROPRIATE SPECIFICATION IN t.1ANUAL FOR GATE YALVES AND APPURTENANCES. FIRE SYSTEM ASSEMBLY DETAIL NTS W-10 REVISED: JANUARY 2009 ~I~ 0:::1 ~~ :::II~ ~IJ. wl9 ll.!i: o(!) lflo:: I I AIR VAlVE WITH CORPORATION STOP (SEE COUNTY APPROVED PRODUCT LIST, APPENDIX F) CONCRETE FOUNDATION (lYP) FULL LENGTH OF METER ASSEMBLY; 4' WIDE, 6" THICK REINFORCED 6 x 6 10/10 WELDED WIRE MESH INSTALL INUNE GATE VAlVE AT PROPERTY LINE OR RIGHT-OF-WAY LINE AIR VAlVE WITH CORPORATION STOP (SEE COUNTY APPROVED PRODUCT LIST, APPENDIX F) DOUBLE CHECK DETECTOR BACK FLOW PREVENTER ASSEMBLY SUPPUED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEAlS. Ul/FM APPROVED FOR FIRE SERVICE INSTAlLATION. INSTAlLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M-14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) (FlANGED GATE VAlVE WITH RISING STEM AND RESILENT SEAT (lYP) 12" SPOOL PIECE INSTALL INLlNE GATE VAlVE AT PROPERlY UNE OR RIGHT-OF-WAY UNE :. . .. ADJUSTABLE STAINLESS STEEL PIPE SUPPORT STANPS AS REQUIRED ANCHORED TO PAD (lYP) MAIN SIZE PER UTIlllY PLAN MJ 45 OR 90 DEGREE BEND WITH MJ RETAINING GLANDS (lYP) NOTES: 1. ALL ABOYE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL 2. (4) VEHICULAR GUARD POSTS TO BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMmED FOR REVIEW AND APPROVAL. 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACILITIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERlY OWNER, STARTING AFTER THE INLlNE GATE VALVE AT THE PROPERlY LINE OR RIGHT-OF-WAY LINE. 5. COUNlY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INLlNE GATE YALYE FROM THE FROM THE COUNlY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNlY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPOXY PAINT. W-11 REVISED: JULY 2011 FLANGED GATE VALVE~ WITH RISING STEM AND RESILIENT SEAT (lYP) DOUBLE CHECK DETECTOR BACKFLOW PREVENTER ASSEMBLY SUPPLIED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS. UL/FM APPROVED FOR FIRE SERVICE INSTALl.ATION. INSTALl.ATlON AS REQUIRED BY COUNlY ORDINANCE AND AWWA M-14. (SEE APPROYED BACKFLOW DEVICES, APPENDIX G) I I I o::l~ 01:J ~I~ :J~ I ~I:S WI' 2iIX o::Q Il.O:: I I VEHICULAR GUARD POST (TYP)" INSTALL INLlNE GATE VALVE AT PROPERTY LINE OR RIGHT-OF-WAY LINE ~ g L... NOTES: 1. ALL ABOVE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE ST~NLESS STEEL YALYE SETTER (SEE COUNlY APPROVED PRODUCT LIST, APPENDIX F) .". ..' . ..". 4' ...'... ," : ~' ",4' , , 4, ' CONCRETE FOUNDATION (lYP) 4' WIDE x 5' LONG, 6. THICK; REINFORCED 6 x 6 10/10 WELDED WIRE MESH .' 2. (4) VEHICULAR GUARD POSTS TO BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMITTED FOR REVIEW AND APPROVAL 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACILITIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAlNT~NED BY PROPERTY OWNER, STARTING AFTER THE INLlNE GATE VALVE AT THE PROPERTY LINE OR RIGHT-OF-WAY LINE. 5. COUNlY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INLlNE GATE YALVE FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNlY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE P~NTED WITH RED EPOXY PAINT. REVISED: JULY 2011 )-,~o: ~ ~ ~ :..J 0 W ~ ~Ull&. 'It wS o:i 0 ~ ~...... w -' w~o ICI 0 I&. 0 Ul w ::11 ~5 ID~ ~ ~ ::11 e~~'6' 0: ::l J: liiEJ ~ln~~<~ ~o:~ ::11 ~ Ul :J~ w ~8lL~ ~~R:z~ffi Ul :::> z :::> 0::11 ...... ~~ll. 00: ~ 0 I&. EJz o:~O'<t ~~ 0 U ...... ~~15 ~ ~ ......)-,Ww Ul>W :::>0 ~ 1=;0 ~~ ~ ~ ~:..JUO: ~~ ~~~~lIi 000:- O:woo: :::> ::I1o~ w ~ ~OOR:lL 0:-' U~ 0: Ii; "-"wLL.c 1l.255lnw~ Ul ZUl~W sg~~ 0 0 ~~~9 oln ~~ ~~~ 0:::> Ul ~ 0: 11. ~~ OU~ 0 ~O I&. ~ 0 '<0: ._~ Zo:o:O ~W ~oId :Z~~ OU 0 ~ ~ OW:':: i~~~ O:w 3= ~t:i20 0: ll.u ~~Ul~O~ 1l.J: :::> O::l1J:~ W~_:::> ~ ~~ w CI CI I&. ~, 0: ~6 ~~s:- ZO:~~:.:: 00 z 1&.' 0 ~ ~~ w~ll:L< U ~~ 52 ~01O~ lLowo: ~WO ~~~ln5~ z c3 w. 0 )-, ~ Z 0:~01O , 5~ffi ~ o:~uo 0 ~ ~~~ >C DO U z wEww>-~ E 0 U 8~Co~ ~ w!5~ R:~~uoo~ ~ ~ 0: ~I&. OCU~OIl. , ~ ffi......o w!!:!;!~~~ 0 11. DO U Ul~Ul g~Ul 5 w is ffio~ 8!5~~6l:i 0 ~ t:iR:8 O:Ul lLo:.e w 0 Vl ::11~< z z::l1lS g 0:: ol&.~ I >-t- ~~E w z ::11 0 ...Jw g:::>~ <11. CI 0 Vi m~ z u :::> ~ 0: ....... wO a: I&. D-~8' OOUl a: ~. ~ w= VlOO ~~~ ~~ 0 Vl...J lLOOO z ~;o :::> << Z::l1 Ul~ 0 -' -,ww 0: ~ o::=> <Il.Ul CI- wO i5~~ zl"l CI. ~~ wO ~~ ~8 Ul t- :i ~~ 0: W ~ Z 11.0 Z > ~ ...J<( ~~ ~~ <~ -oi ICi iii ,..: !Xi =>W 00:: ~ r:i WG: z U. 0 'W Ww 0: 0:::11 Zz >'0 -w ~a ~:J 0:: ~oo ::I1g ~~ W g~ 0 Vlo:: Zz WW W 11.11. OUl :::>0 00 W > ffi!3 of 0:0: 0:: 0 0 ~U 11.11. u.. 0 :::> ffiCl 0 00: ~~ :I: ~~OO~ 000 ~~ !:: w b<...... CloId 8'< ~ 0lt;Jll. ~~ Zw o:o:~ ~Z~ ~> o ...... wZ woo i~ ~ in~\g ~~ 0000: 9 wll. I&. ~E~ ~~~ ~~ ~ o~w~ ::l - o:::~ ::I1~CI ~8~~ ~ci I!?:::>o o~ I/) ~::l~ >0: wl"l W:J . ~ow ~Ul 11._ ZzW ~~oo cw15 ~wz o:Ul~w ~~I ~~ ~-z Z:J ~oo- Ow:J w:J:>, wWo:O: :::>O~ ll:li!:~ ClOOll.lL zU z~~ sg~~ wll.~ :::>w...l CI~O: ::l0:3= :J0:1 z~ w Oo:W zO: ~~I&. :Jll.Qz o::::>~ so~ -$J. Zo:o:O z O::J ClUl ~ 0 -'00 -.-, ~laUl :::>~ I :;i0:1 ~www -,'<0:>- t:iwo: ~CI~ lnll.8 z- :;i~o~ oo:~ 2:::>~ w~_:::> i5C1 ooZCI 0: ~6 lii:a!w, ~':z ::11~- z.-,- ~ >lL::I1 w 0: _<0: ~>~~ lLowo: ::l~~ zoo ~ln25 -;:-0:::> <11. ......UUl ~ N ,..; W-15 REVISED: JANUARY 2009 ~ LlJ 0::: ~1=' ~ 0 LlJ . ~ !;}50 LlJo~ LlJ5 LlJ oo~o o:::~ 0::: :I: ~~~ ~~~-(5 a.. i3~!!i ::I en ~5 LlJ lD~LlJ~O o a.. ~ 2 0:2: 00 I'-LlJ i3~eno~ zo:::~ I-~ x_~ 'ii:'~~~ ~o:::o::: ~en~~~ ~~a.. 00::: en zlil...-::. ....... ~lDO:::- _LlJe:: ~~ 0 ~~u a.. ~o~ LlJ !Ze:: :ll: ~ t -.JLlJu.o ~~~ 0::: :::>~ ~~ ~:zl:;j Zen~LlJ ~~~8 00 . ~~~9 zo ~~ ~ t;; LlJLlJ LlJEO::: ffi~~ ~~o~~ eno~ 0 ~ffi~~ 0::: 0:::> en :::>~< a.. 3l:;jS:20 <-' a !;} g:LlJ~lilli! ~o LlJ ;I: O:::oLlJ u. 0 00 0 lD~lil ~ 0:2::I:- ~LlJO::: ~ ~a..~a.. O:::LlJ u. 1-, z~~ ~o::: :::>~ LlJ u.. 0 0 og~a ~F 8 ~~3 <-' !;}OlD- ~eno ~~~~t:l ~ o:::~~~ ~~ LlJ ~g LlJ en:I:o ~ ~ OLlJ ~z~ )( LlJoLlJ ~o':)~e LlJ ~u.0::: 8~io~ ~t~ ~:::>z"" ~o F ~ lDo<-, -J 0::: z~ i3:ll:~ 0::: .0'1 LlJ LlJ. :2: ~~~~:2:S ~~~S 0 0 en en en 0:2: ~ a.. ~ii::::> -lD LlJ !;}~ en i ~ enenzen 5~ 'iI1 0 ~ ~~ o~ffi~<~ eno 0 e:: LlJ 9 ~~ ~~~I'- ~~ 0::: :ll: lD- LlJ u. -.J LlJ oElD ,oa.. ZIil:2:o LlJ:::> u. E :ll:..,.a.. ~~~~~~ :c( zLlJ o~ 0 ~_o In~:i~ ~ 10::: 00 j:; -JO::: :2: 0 :2: a.. LlJLlJLlJ~ ~~ .~ ~m :::> :2: ~ 0::: . -J:JZ ~a..OZ Z o<en lDa.. 81n :::>LlJ< I'-~LlJ :::> a.. :J Inen~ :i ~ ~<~ O:::>-Z :::>LlJ:::>cD ~<i! oenen_ < ~a..a ~:::> LlJ o~rt: a:~n :::>z LlJ lD 8~ lD' ~ LlJo~ <-' ~ ~~ O:::LlJ 0::: :::>z~ 0 ~e:: ~~ en ~ en~ ~ LlJLlJ:::> ~~ 0:::00 <-'en LlJ ~~~ lD Z Z~ :2: 0 ~:::> ~g LlJ a.. ~rnl1 z ~~ en :2: ~ 0 8O~ 0 a.. < 0 LlJ ~ :ll::I: -J;'" en :~g 0 0:::(5 U ~~ <i!< ~ !;}o UJ :2:~ Vl iii cD r.: !Xi 0 ~~ en~ Z ~ ~~ 0 LlJLlJ :2:LlJ Zz 0::: ~LlJ LlJ:2: ~:J LlJ o~ ~ ~lD en:::> o!;( ..,.0 :~ I- t\ ~---~ !3~ ~g ~~ ~;I: ;:;;-~O 00 oen Zz LlJLlJ ~~a.. is en a.. a.. I-~ :::>0 00 en~ ~ :::> ~~ 01= 0:::0::: a..:::> ~en 5 ~o a.. a.. 2, en 0 :::> :::>0 o ~ ~- ~ 1 g~ 5 LlJo o~ ~~ ~o OlD LlJo ~8 o:::LlJ ~:J ;j~et:' 0:::<-' ffi <-'z lil~ ~F ~-J~LlJa..~ 00::: a.. ~< Z ~:2: 1o!i LlJ ~z;a! ~~ 0 :::> 0:::> 00. ~~ ~~ 0 ~ s:' 0 ~ t;; ~ ~ffi ..,.:c( ~ LlJO:>' ~~ LlJ ~ t;J en lDOO NW o -J ~ a.. -lD .".~' ~~ LlJO::: zLlJ iii~~ t; Z LlJ ~ ~ lD 1-a o~ ~o::: z g~t ~~ 0> < 0 I- - E:::> ~ ~ ~~ ~LlJO L.:ffi ~~~lii~~ v..,)~->'o ::I. ~ lDo:::lil ~ o:::oa..~ ~z oO:JLlJo 0 ~o ~:::>o o!i -LlJ \I) o::l~ ~~ :>'0::: ~cg5 ~~<-'~~I-g~ LlJI') LlJ:J . ~en a.._ ZzLlJ ~~~ ~ ffio:::~E' a..~ o Z~OO~ OLlJ~ ~-z 00 < iii 0:::> :ll: ~~ OLlJ:J LlJLlJ t;;~ - 0 0 ~lD- ~z ~~:J zl:;j~~~ a.. 0 0::: EO LlJO zO :::>O~ ~F~ :::>:J LlJ >- ~:2:_0 za.. g~ ~g:~o :::>LlJ.J <-,1-0::: az z~~ ~~~ 0 o~ -.J< enLlJ ::10:::;1: w- 0:::8 ~lilen<-, Oo:::LlJ ~zo::: O:::LlJ ~o::: I LlJ LlJ LlJ LlJ ~ . o::::::>~ 0f2 -~J. ::IF LlJ :.J> LlJ:::> Clen ~ 0 _~u. o:::~~o::: 0::: ot;; ~~ ~o g:~ LlJ~en :::>~ I ~<-' ~~9 e::_ e::e:: o 0 a..:J o g: ~o:::~ x:::>~ ~<-'~ ~~ Ina..~ ~t; t;;~ ~~ lDa.. ~~:i ~zQ 0:::> ~ < .z LlJ~O::: z:::> . ~~ii: 0 ~~~ .~~ ~Iil~ :::>-JZ '0 E~ 3Nn AVM-.:lO-lHm~ oo~ -.Joen o~ ", ':~a.. - -~O 3Nn .illJ3dO~d -- 01...... ~~ - N ..; . -J ~o::: >- W-16 :>'~ ;;j,LlJ ~ LlJOI~ 0::: a.. In~~~ ~~~J.~ REVISED: JULY 2011 <~ ~~~:>,~g::Jii:o:J Approved Backflow Devices VENDOR SIZE MODEL NO, TYPE USE Ames / Watts 3/4" - 2" 400B /919 RP Residential or commercial potable water locations Watts 3/4" - 2" 909-009 Series RP Residential or commercial potable water locations Wilkins 3/4" - 2" 975 RP Residential or commercial potable water locations Ames / Watts 2,5" - 10" C-400 I 957 RP Large size meter - potable water for commercial or residential applications Watts 2,5"-10" 909 RP Large size meter - potable water for commercial or residential applications Wilkins 2,5" - 10" 375 RP Large size meter - potable water for commercial or residential applications Ames 3/4" - 2" 4000B-LBV Combo services: fire and domestic 4000B-FP RP lines Watts 3/4" - 2" 009LF RP Combo services: fire and domestic lines Wilkins 3/4" - 2" 975XL (w/OS& Y only) RP Combo services: fire and domestic lines Ames Colt 2.5" - 10" C-400 (w/OS& Y only) RP Combo services: fire and domestic lines Watts 2,5" - 10" 909 (w/OS& Y only) RP Combo services: fire and domestic lines Wilkins 2,5" - 10" 375 RP Combo services: fire and domestic lines Ames Fire Lines - Standard 2" 3000B DCDA Watts Fire Lines - Standard 2" - 3" 007 DCDA Wilkins Fire Lines - Standard 2" 950XL TDAF DCDA Ames Fire Lines - Standard 2,5" - 10" C300/M300 DCDA Watts Fire Lines - Standard 3" - 10" 709 DCDA Wilkins Fire Lines - Standard 2,5"-12" 350 DCDA Wilkins Fire Lines - Standard 4" - 10" 450 (N-Shape) DCDA Note: All fire line Backflow Devices shall be UL or FM approved for fire service installation Above is a small list. others may be used if requirements are met and information is provided ' Appendix G Rev, 07/2011