Ordinance 89-046Om~INANCE NO. 89-46 co, l IER ELECTRIC^L CODE _ AN ORDINANCE ENACTING ONE PART OF THE COLLIER COI)]~ ~ ~.~ BUILDING CODE" BY ADOPTING THE "NATIONAL EtECTRI~ PROTECTION ASSOCIATION, AS FUR~ER ~E~ED BY TIII~ EDII'ION. TO ADD ARTICLE 80. ADMI[~STRATTON. CONSIST]N(: ",?~ ~', OF ARTICLES flq-A TItROUGII 80-J, MORE SPECIFICALLY DE- SCRIBED AS: 80-A, TITLE AND SCOPE; SECTION (llERINAFTER NOTED AS S.) 80-1, TITLE; S. 80-2, CODE REMEDIAl.; S. 50-3, SCOPE; S. 80-4 RELATING TO M2XINTENANCE OI; ELECTRICAL SYSTEMS; 80-B, ORGANIZATION; S. 80-5 ESTABLISHI~:G ELECTRICAL SECTION AND CltARGE TIIEREOF; S. 80-6 RELATING TO INSPECTORS; 80-C, POWERS AND DI!TIES OF ELECTRICAL OFFICIAL; S. 80-7 RELATING TO RICliT OF ENTRY; S. ~0-8 RELATItIG TO STOP WORK ORDERS; S. 80-9, PROVIDING FOR REVOCATION OF PEF}IITS;S. 80-10 REI.ATING T~ UN.RAFE INSTALLATIO]<S; S. 80-11 RELATItlG TO ~FC, I!IRI.I,II':NTS NOT COVERED BY CODE; S. 80-12 RI':I.ATIN{; TI) INSTALLATIOMS OF AI,TERNATE MATERIALS OR ALTERNATE ~;ETItODS OF INSTALLATIONS OF MATERIAl. S; S. 80-13 RELATItlG TC LIABILITY OF OFFICERS, EMPLOYEES, OR EN FORCF.}IENT BOARD HEP, B ERS; 80-D, APPLICATION FOR PERf.;IT; S. 80-14 RELATING TO ],'HEN A PERMIT IS RE- QU1 RED; S. ~0-15 REI.ATING TO APPI.ICATION FORtl; S. 80-16 RELATIt;G TO DRAWINGS AND SPECIFICATIONS; S. 80-17 PROVIDING FOR EXA}~INATION OF DRAWINGS; 80-E, PERMITS; S. BO-If REI.ATING TO EI.ECTRICAI. OFFICIAI,'S ACTION ON I'FEI'!IT AI'I'I,1CATIONS'. S, 80-19 REI.ATING TO CONDITIONS OF TIlE PEF. t':IT; 80-F, FEES; S. [10-20 PROVIDING FOP. A SC}iEDULE OF FEES AND CHARGES TO BE ESTABLISI!ED BY REEOLUTION; SO-G, INSPECTION; S, 80-21 RELATING TO INSPECTIOHS; S, 80-22 RELATING TO NOTIFICATION OF INSPECTIONS; S, 80-23 RElaTING TO MATEPIAL AND LABOR INSPECTIONS; S,80-24, RELATING TO II';SPECTIONS FRICR TO CONCEALHENT; 80-H, CERTIFICATE OF APPROVAl,; S, 80-25 REI.ATING TO FINAl. INSPECTIOMS; S. 80-26 RELATING TO TEMPCI~ARY APPI~OVAL; 80-! RELATING TO VIOLATIONS AND PENALTIES; S. 80-27 PENALTIES; 80-J PROVIDING FOR APPEALS TO THE BOARD OF ADJruSTME~;TS AND APPEALS; S. 80-38 APPEALS; AMENDING ARTICLE 100 RELAT!HG TO DEFINITIONS; AMENDING S. 210-52 TO ADB SUBSECTION (g) REI~TINC TO OUTLETS; AMENDING S. 230-7 TO ADD SUBSECTIOF. (n) RELATING TO CONDUCTORS IN RACEWAY; AMENDING S. 230-21 TO ADD SI{B.qECTIOM (~) RELATI~iG TO OVERHEAD SruPP1.Y; A~IENDINC SECTION 230-23, 230-31 AND 230-42 lb), RELATING TO RATING; AMENDING S. 230-43 RELATING TO COMDUCTORS; AHENDING S. 3C0-1 TO ADD TO SUBSECTION la) WIRING {IETIIOI)S; At;In ,*MFI'.'DT{'IC, S, 300-1 TO ADD SUP. SECTION 300-1 lc) EEI.ATING TO CONDUCTORS IN RACFt.,AY; AtlENDING S. 310-16 REI.ATING TO AMPACITIES; AMEN'DING S. 336-3 FYI.ATI~;C TO I't.k};133'El? rruSES AND EATERIALS; AMENDING S. 5.c0-23(a) TO AI~D SUBSECTIONS (1), (2), AI~q) (3) RELATING 3o biOBILF I,OMF?: A)'F[;D]NI; f. 680-20 la)(1) AND (2) ltl I.A','II'.(: *I'(' t':;l'l I~W,VI'I-.I; I.l(~li'{ Il'ii I'I)VI'URE:;I RI.'.I'I.'.At. II:(: t'l'.l>llb'~t:CE 8(,-53; I{~OVIDI{':G l-'Ol', CGNFL1CT /~ND SEVERANCE; F~OVII)It;G FCR ,.\~ EFFECTIVE DA'IE, NOW, 'TllEI~EFOPE, F.E 1T ORDAINED BY TIlE {~OARD OF COU'NTY COMHISSIONERS OF COLLIER COUNTY, FLORIDA: SECTION ONE: The "National Electrical Code, 1987 Edition," as published by the National Fire Protection Association, and as amended herein, is adopted by taference ns the "Collier County Electrical Code". SECTION TWO: The "National Electrical Code, 1987 Edition," is hereby steaded to read aa followa~ ARTICLE 80 - ADMINISTRATION Add Article 80 to read as follows: ARTICLE 80 - ADtIINISTP. ATION A. - TITLE AND SCOPE 80-1 - TITLE The provisions embraced within the followin$ chapters and sections shall constitute sad be known and may be cited a~ "The National Electrical Code," hereafter referred to ao "thie code." 80-2 - CODE REMEDIAL This code is hereby declared to be remedial, and ~hnll be construed tn secure tha beneficial tn~eres~ purposes thereof, which are public safety, health, and general welfare, by regulating installation and maintenance of all electrical equtpmen~ and systems. 80-3 - SCOPE The provisions of this code shall apply to 'the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures and fittings. 80-6- ~INTENANCE All electrical systems, both existing a~d new, crd nil parts thereof, shall be maintained in a safe condition. All devices or safeguards which are required by this code shall be maintained in good working order. The maintenance of electrical systems shall be the responsibility of tbs owaar or his destgnatsd agent. ORGANIZATION 80-5 - ELECTRICAL OFFICIAL There is hereby ast~blishsd a dspartmsnt to bs called the Electrical Department and the parson in charge shall be knovn as the Electrical Official. 80-6 - INSPECTORS Tbs Electrical Official nay appoint such'nmnbsr employees as shall be authorized from time to time. C. - POWERS AND DUTIES OF ELECTRICAL OFFICIAL 80-7 - RIGHT OF EI~TRY The Electrical Official shall enforce tha provisions of this code and he or his duly authorisad representative may enter any building, attmcture' or premises to perform any duty imposed upon him bi this code, 80-8 - STOP ~ORX ORDERS Upon notice from the Electrical Official that work on any electrical installation is being dona contrary to the provisions of this code or in a dangerous or unsafe manner, such ~;ork shall be i~nedi~tely stopped. Such notice shall be in v rising end shall be given to the o~ner of such property, or to his agent, or the person doing the vork, ~nd shall state the ccnditions under which work may be resumed. ~ere any emergency exists, oral notice given by the Electrical Official shall be sufficient. 80-9 - REVOCATION ~F PER}!ITS Tbs £1sctrical Official mai revoke a peruit or approval issued under the provisions of this Ordinance in case there has been any false statement or mis~epresentations as to a uaterial fact in tha application or plans on which the peruit or approval (3) vas based, In all such cases perait fees shall be refunded. 80-10 - LrNSAF~ INSTALLATIOKS Ill eltctrical installations~ ~elardlssa of type, ~hich constitute a hazard co huaan hearth, or velfare are hereby declared illegal and the electrical power shall be ordezed disconnected. 80-11 - REQUIPJ'~liNT$ NOT COVERED BY CODE Any requirement necescary for the safety, scranich or stability of an exiscin$ or proposed installation, or for the safety of the occupants of a buildi~ or structure, not specifically cove~ed by chis code, shall be determiued by the £1eccrical Official. 80-12 - ALTERI~ATE }~TERIAL$ ~ ALTE~ATE~THOD~ OF Alternate =a~arials and alternate methods of installations shall ba approved in accordance ~ch ~his ~eccion: (a) For exis~in~ sc~ccures or p~ises in vhicb electrical insCalla~io~e a~e Co be altered, repai~ed, or renovated, the ~leccrical Official have the authority Co pe~i~ deviation from the provisio~s o~ ~bis Code, provided Chac such a '. proposal to deviate is ftrsC submit~ed Co the electrical ~eccion for ~evtev to assure that health aud safety requtzenencs, as they pertain Co elec~ricfll insralla~ions~ age obae~ed. (b) Provisions of Chis code are nsc tnceudtd to prevent the use o~ any nacerial, device~ method o~ installation, or fixture, not specifically ~uchorized, provided such alternate has been approved by the Electrical Official. (c) The ~l~ctrical Official shall suificien~ evidence to enabl~ him Co Judge proposed al~err~tea neet the requirements st Code for safety and health. (d) ~here there il not sufficient avl(lance to substantiate claims for alternates, the Electrical Official ~ay require teats of compliance as proof to be ~ade by an approved asency at ~he expense of the applicant. Tests shall be made in accordancs vith generally recognized standardal but in the absence of such standards, the Electrical Official shall specify the test procedure. Testa ~ay be required to be repeated if, at any time, there ia reason ~o believe that an alternate no longer confor~s to the requirements cn vhich its approval vas based. 80-13 - LIABILITY Any officer or employee, or member of any Board, char~ed with the enforcement of this code, acting for the local governing body in the discharge of his duties, shall not thereby render himself liable personally and he ia hereby relieved from all personal liab£1ity for any damage thac may occur ~o persona or property as a result of any act required or perr. it~ed in the discharge of his duties. APPLICATION PCR PER/tIT 80-1~ - I~EN REQUIRED A person, rim, or corporation shall not do or cause :o be done, any installations, alte~ationa, repairs, or replacement of equipment or systems covered by the provisions of this code, ~ithout first having obtained the proper pert. it from the Electric~! Official. Ordinary repairs, limited to $200.00 value or less, u~ay be ~de vithout a per. it provided ~ha~ such repnirs shall not violate any of the provisions o[ this ccde and aubJec~ to l) o~r. ers or representative ~itten permission; 2) no inspection required; and 3) repnired by o~fler or licensed contractor. (~) 80-15 - FORM The applicant shall furnish such information as may be required to co=plate the application forms. 80-16 - DRAWINGS AND SPECIFICATIONS Whenever, in the opinion of the Electrical Official, drawinzs and specifications are needed to depict or define the nature and character of tbs work for which the application ia made, the applicant shall furnish drawings, s~ecifications, panel scheduls and calculations. The applicant shall furnish savsral copies to coincide with the permit review process for the project. The applicant's approved set of drawings, specific~tions, panel schedule and calculations shall remain at all times on the Job. Such information o: drawings and specifications shall be specific, and this cods shall not be cited as a whole or in p&~t, nor shall the term "legal" or its equivalent ba lsgued as a substitute for zpecific information. 80-17 - EXAMINATION OF DPAWINGS The Electrical Official shall examine or cause to be examined each application for a permit and the drawings and specifications which may be filed therewith, amd shall ascertain by such examination whether the installation indicated and described-is in acccrdance with the requirements of this code and all other applicable laws or ordinances. E. - PEP}lIT 80-18 - ACTION ON APPLICATIONS Ca) If the Electrical Official is satisfisd that the work described i~ an application for permit and the drawings and specific~tions which may be filed therewith, conform to the requirements of this cede, and other applicable laws and ordinances, he shall issue a permit to the applicant which shall be (6) posted on the ]ob sits so that, whenever possible, is visible from the street. (b) If the application for pe~it and the drawings and specifications which may be filed therewith describe work which does not conform to the requirements of this code or other applicable laws or ordillancas, the Electrical Official shall not issue · permit but shall return the drawings to the applicant with his refusal to issue such a permit. Such refusal shall, when requested, be in writing and shall contain the reasons therefor. 80-19 - CONDITIONS OF TllE PERMIT (al The Electrical Official shall act upon application for a permit with plans as filed, or as amended, without unreasonable or unnecessary delay. A permit issued shall be construed to be a license to proceed with the work and shall not be construed as authority to violate, cancel, alter, or set aside any of the provisions of this code, nor shall such issuance of a permit prevent the Electrical Official from thereafter requiring correction of errors in plans or in construction, or of violations of this code. Any permit issued shall become invalid unless the work authorized by it shell have been inspected within six (6) months after its issuance or if the work authorized by such permit is suspended or abandoned for a period of six (6) months after the time the work is inspected; provided, that for cause, one or more extensions of time for periods not exceeding ninety (90) days each, may be allowed in writing by the Electrical Official. (b) Plans for new construction or any change in existing electrical installation over 400 amps on restdentinl and over 400 mnps on commercial or industrial zhe]l be prepared by, and each sheet shall bear the impress seal of, a Florid· Registered Professiovsl Engineer and shall conform with the laws (7) of the State of Florida, The plans shall show the c~lculations, size of service and ~aximum avsilable fault current and interrupting capacity of ~ain and sub-feeder breakers or fuses, wires and conduit, the location o~ service svitches and center or centers of distribution, and the arrangement of circuits showing the number of outlets connected thereto. The Electrical Official shall examine all plans for compliance vith the Electrical Code. It shall be thc duty of the architect, engineer and builder to obtain ~eter and conduit locations from all utility companies for all types o~ service before construction is comaenced. Such ~eter and conduit locations shall be indicated on the dra~ings. (c) The installstion of uhe ~iring, apparatus or equipment for light, heat or power! within or attached to any building or prcaises whether fo~ private or public use, shall be done in accordance with the apprnv~d plans and spscifications and shall confot~ to the Collier County Electrical Code. Any chsn~es or omissicns in ~he viring system ~rom that sho~n cn per~itted plans must be reviewed by ~ha Electrical Official and the request !ct the change shall be made by the permit holder, snd ~pprove~.by the o~rner and original engineer or his representative or engineer appointed by architect of o~iginal plan. Three (3) copies of the plan shoving the chan~e muse be submitted ~i~h all sheets bearing tbs original engineer's seal as provided for above, F. - FEES 80-20 - COST OF PE~HIT The Board of County Cmmnissioners shall establish, by resolution, a schedule of fsss and charges for matters pertaining to this Ordinance and sssociated matters, It is the inteut o~ thesa reEulatlons that the County shall ncc be required to bear any part of the cost of applications made under this Ordinance, The schedule cf fees and char/es shall be posted in the office of the Development Services Department. The char~es listed may be changed by resolu:lon of the Board o£ County Cot~r. issioners and are not subject to the procedure otherwise neceosary for amendment of this Ordinance. ''G, - INSPECTION 80-21 - INSPECTION REQUIRED All new work and such portions of existing system~ a~ ~y be affected by new work, or any changes, shall be inspected to insure compliance with all the requirements of this code and to assure that the installation and constrnction of the electrical system is in accordance with approved plans. 80-22 - NOTIFICATION Advance Notice: It shall be the duty of the permit holder to give reasonable advance notice to the Electrical Official when work is ready for inspection. Reinspection: If the Electrical Official finds that the work will not pass the inspection, the installer shall be required to make necessary. e~rreeticns find the work shall then be resubmitted fcr inspecti~n. ~ere additional inspections are necessary, there shall be an additional fee for each such'inspection as indicated in the schedule of fees and charges. 80-23 - }~TERIAL AND LABOR INSPECTIOMS The equipment, material, power, and labor necessary for the inspection shall be furnished by the installer. 75 B0-24 - INSPECTIONS Any portzon of an electrical system islanded to be concealed by any per~,anent portion of the building shall not be concealed until inspected and approved by the Electrical Official, Equipment regulated by this code she1! not be connected to the fuel or powsr supply or plseed in cperation until it complies with all applicable requirvnents of this code and a final inspection approval has been issued. A final inspection approval may, upon notice, be revoked by the Electrical Official if it is fouvd that the electrical ~ystem fails in any respect to comply with the requirements cf this code. The Electrical Official may accept inspection certification reports from a nationally recognized approval agency in lieu of on-site inspection when on-site inspection is impractical. H. - CERTIFICATE OF APPROVAL 80-25 - FINAl, INSPECTION Upon satisfactory completion and final inspection of tile electrical installation, a certificats of approval shall be issued by th~ Electrical Official. The building shall not be occupied prior to completion of said system and/or issuance of certification of approval. 80-26 - IE}~ORARY APPROVAL A temporary certificate of approval may be issued for a portion or portions of an slectrieal system ~hich may be safely operated prior to final completion of the building. 1. -VIOI. ATIO~S AND PENALTIES 80-27 - VIOLATIO~;S AND PFPAI,TIES If any person, firm, corporation, or other legal entity whether public or private, shall fail or refuse to obey or co~ply with, or violates, nny of tile provisions of this Ordinance, such person, firm, '. corporation, or other legal entity, upon conviction of such offense, shall be punished by a fine not to exceed Five llundred Dollars ($500.00) or by imprisonment not to exceed sixty (60) days in the county Jail, or both, in the discretion of the court. Each day of violation or non-ccmpliance shall be considered as a seFarate offense. In agdition, any person, fir=,, corporation, or other legal entity whether public or private, convicted under the provisions of this section shall pay all costs and expenses involved in the case. Nothing herein ccntained shall prevent the County from taking such other lawful action in any court of competent Jurisdiction as is necessary to prevent or remedy any violation. Such other lawful action shall include, but shall not be limited to, an equitable action for injunctive relief and an action at law for damages. J. - APPEALS 80-28 - APPEALS Whenever the Electrical Official shall reject or refuse mode or manner of construction prcposed to be followed or materials to be .sod in the erection or alteration of a building or structure, or when ~ is claimed that the provisions of this code do not apply, or that an equally good or more desirable form of construction can ~e employed in any specific case, or when it is claimed that the true intent and meaning of this code or any of the regulations thereunder have been misconstrued or wrongly interpreted, the c~mer of such building or structure or his duly authorized agent, may appeal from the decision of the Electrical Official to the Board of Adjustments and Appeal., pursuant to the procedures as set forth in the Collier County Ordinance e,tablishtng the Board of Adjustments and Appeala. ,oo, 036,,: 77 CHAPTER 1 - GENERAL ARTICLE I00 - DEFINITIOf$ A. - GENERAL Amend section by adding the following definitions: Electrical Official - The electrical official is the County M~nager or his designee. O~er - Any person, agent, firm, or corporation having a legnl or equitable interest in the property. CHAPTER 2 - WIRI}!G DESIGN ~h~ PROTECTION ARTICLE 210 - BRANCH CIRCUITS C. REQUIRED OUTLETS 210-52 - D~ELLII;G l~IT RECEPTACLE OUTLETS Add subsection (g) to read as follows: (g) Refrigerators and fixed appliances shall be wired on individual minimum 20 ampere circuits and 20 amp receptacle. ARTICLE 230 - SERVICES A. - GENERAL 230-7 - OTHER CO!~UCTORS IN P~CEWAY OR CABLE Add subsection (a) to read as follows: (a) Separately metered conductor~ ahall no~ be installed in the same raceway. Line and load conductors mhsll not be run in the same raceway, trough or wire way. B. - OVERHEAD SERV!CE 230-21 - OVERHEAD SUPPLY Add subsection (a) to read as follows: (a) All services shall be rum in galvanized rip, id threaded met~. conduit or intermediate metal ¢cr. duit from mast head to meter. Rigid non-metallic and electrical metallic conduit may be used where permitted by the Electrical Official. The diameter of a roof mast shall be a minimum ot two (2) inches. 230-23 - SIZE AND RATING A~end subsection (b) to read as follow{l: (b) A minimum 100 ampere service shall be provided for all dwelling units and commercial structures, Delete exception to 230-23(b). C. - UN~ERGROU}~ SERVICES 230-31 - SIZE AI~ RATING Amend subsection (b) to read as follows: (b) A minimum I00 ~mpcre service shall be provided for all dwelling units and commercial structures. Delete exception to 230-31(b). D. - SERVICE - ENTRAMCE CONDUCTORS 230-42 - SIZE AN~ P~,TING 230-42(b) - UNGROUNDED COh~UCTORS Amend subsection (b) to read as follows: (b) A minimum 100 ampere service shall be provided for a]l dwelling units and all co~ercial structures. Delete (1), (2), (3) and exceptions tO 230-42(b). 230-43 - ~.~IRING }~THODS FOR 600 VOLTS, NOHINAL, OR LESS Amend section 230-43 to read as follows: Service entrance conductors shall be installed in accordance with the applicable requirements of this code covering the type of wiring method used and limited to the following methods: (1) rigid metal conduit; (2) intermediate metal conduit; (3) rigid nonmetallic conduit schedule 80 and electrical metallic conduit where permitted by Electrical Official; (4) busw~-s. CF~P%ER 3 - WIRING METItODS A~ }~TERIALS ARTICl.E 300 - WIRING METHODS (13) Ao - GENERAL REQUIREMENTS BOO-l(a) - ALI, WlRIMG INSTALLATIONS Amend subsection 300-1(a) by adding Exception No. 6 to read as as fol!ows: Exception No. 6: Type NM and ~!C Cables shall not be permitted in any structure except as provided in Section 336-4(a) of this ordinance. 300-1 - SCOPE Add subsection (c) to read as follows: 300-1(c) -. [)~tER CONDUCTGgS tN ~CEWAY OR CABLg (C) Separately metered ccnduct~r~ shall not be installed in the same raceway. Line and load conductor~ nhall not be run in the same raceway, trough or wire way. ARTIC1.E 310- CONDUCTORS FOR GEt;EPAL ~4IRING TABLE 310 ANPACITIES Amend Table 310-16 Title to read as follows: Ampacltlss of insulated conductors 0-2000 volts, 60°C to 90'C, not more than threa (3) conductors in raceway or cable or earth (directly buried) based on ambient temperature of 30'C (86'F). ARTICLE 336 - I¢OI,~TALtlC-SI[EATIIED CABLE 336-4 - [SIS NOT PEDIITTED '. Amend subsection 336-4(a) to read as follows: TyFe l~l and NMC cables shall not be permitted tn any ~tructur~a except renl¢!~ntlnl structures three (3) utori~s or less in height. Areas in residential structures identified for other occupancy cla~ificatiou uses shall be in conduit and conform to all appropriate sections of the code. " (~4) '. CTIAPTER 5 - SPECIAL OCCUPANCIES ARTICLE 550 - HOBILE tlOI.<ES AND MOBILE HOME PARJ~S B. - HOBILE HOME PARKS 550-23(a) - RATING Add subsections (1), (2) and (3) to read as follows: ([) Every servic~ to a mobile home shall hays an approved main fuse or breaker located at the meter and a fuse or breaker in the mobile home. (2) No electrical power shall be ~upplted to a mcblle horce, except a travel trailer, until the home is tied down in conformity with Collier County Ordinance. (3) Pole for mounting meter and di~connect shall be Class $ er 7 treated wood or equal, to be set a minimum of five feet (5') deep, properly preserved to protect it from decay and insect damage. CHAPTER 6 - SPECIAL EQUIPHENT ARTICLE 680 - SWI}~II}:O POOl,S, FOUNTAINS ~D SIMILAR INSTALLATIONS B. - PERMAXENTLY INSTALLE9 POOLS 680-20 - I:NDEF, WATER I, IGliTING FIXTURES - GENERAl, Amend subsections 680-20(a)(1) to read as follows: (1) Swimming pool and spa lighting shall ba Iow voltage supply frcm an approved transformer and in all ether ways shall conform to the National Electric Code~ Ail pools shall have a rough and final electrical ir..~pect ion. Deletp n,. ,~,ctlon 680-20(a)(2) Renumber subsection (a)(3) as Renumber subsection (a)(/') as (a)(3) SECTION THREE: ~,epeal of Previous Ordinances Ordinance 86-53 is hereby repealed as of the effective date of this Ordinance · SECTION FOURt CONFLICT AND SEVERANCE In tile event thio Ordiuance cot,fliers with any other ordinance Collier County or other applicable law, the more restrictive shall apply. Ii any phrase or portion of this Ordinance is held invalid or unconsti- tutiona! hy ally cm~rC of cmnpeten~ jurlsdlct!on, ~lJch portion ahnll be deeaed a sepnrnte, distinct, and independent prevision and such shall not affect the vnliJity o~ the remntni~ portion. SECTION ~IVE: Effective Date This Ordinance shall become effective upon ~o:tce that it hah been received by the Office of the Secretary of State. PASSED AND DULY Al}OPTED by thr Board'o[ County Co.missioners Collier County, Florida this~ day of ~~, 1989. BOARD OF GOUtI~ CO~ISSIONERS COLLIER COUNt, ~.ORIDA ~ ~__~ -~ ~ Approved as to form ~nd l,gal 89 electric ordinance This ordinance flied with the Secretary of SJ~le's. Officl ~ and ock~wl~dgem~n~ of that (16) STATE OF FLORIDA ) COUNTY OF COI.I.II.:R ) I, JAMES C. GILES, Clerk of Courts in and for the T%¢entieth Judicial Circuit, Collier County, Florida, do hereby certify that the foregoing is a true copy of: Ordinance No. 89-46 which was adopted by the Board of County Commissioners on the 18th day of July, 1989, during Regular Session. WITNESS my hand amd the official seal of the Board of County Commissioners of Collier County, Florida, this 20th day of July, 1989. JAMES C. GILES Clerk of Courts and Clerk Ex-officio to Board of County Commissioners By:~ia Mogri ~ Deputy Clerk