Ordinance 91-060 ORDINANCE NO 91 - 60 ~ '~1 COLLIER COUNTY MECHANICAL CODE ~ ~ U'- ~ ORDINANCE AMENDING THE "COLLIER COUNTY BUILDI~ ~ ~ CODE" BY ADOPTING THE "STANDARD MECHANICAL COD~ u~ 1988 EDITION WITH THE 1989 AND 1990 REVISIONS", AS FUP. THER AMENDED BY THIS'ORDINANCE. CHAPTER 1 ADMINISTRATION IS DELETED; AMENDING SUBSECTION 308.9 RELATING TO CLOTHES DRYER EXHAUSTS; AMENDING SECTION 404 RELATING TO CONDENSING UNITS, FOUNDATION SUPPORTS, AND TIE-DOWNS; AMENDING SECTION 504 BY ADDING SUBSECTION 504.10 RELATING TO FIBER-GLASS DUCT BOARD SYSTEMS; AMENDING SECTION 505.1 RELATING TO FLEXIBLE DUCT; AMENDING SECTION 509 BY ADDING SUBSECTION 509.3 RELATING TO PLENUM CHAMBERS; AMENDING SECTION 603 BY ADDING SUBSECTION 603.6 RELATING TO CONDENSATE DRAIN PIPING; REPEALING ORDINANCE NO. 89-79; PROVIDING FOR CONFLICT AND SEVERABILITY; PROVIDING FOR AN EFFECTIVE DATE. NOW, THEREFORE, BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS OF ~OLLIER COUNTY, FLORIDA, That: SECTION ONE The "Standard Mechanical Code, 1988 Edition wi.th the 1989 and 1990 Revisions", as published by the Southern Building Code Congress International, Inc., as amended herein, is hereby adopted by reference as the "Collier County Mechanical Code" to protect the health, welfare, safety, common interest and convenience of the citizens, visitors, and residents of Collier County, Florida. SECTION TWO The "Standard Mechanical Code 1988 Edition with the 1989 and 1990 Revisions", is hereby amended as follows: CHAPTER I - ADMINISTRATION Chapter I is deleted in its entirety. Refer to the Collier County Building Construction Administrative Code. All references to Chapter i shall be interpreted to mean the Collier County Building Construction Administrative Code. CHA~TER 3 ~IR CONDITIONING, HEATING ~ VENTILATION EQUIPMENT 308 EXHAUST SYSTEMS 30G.9 Clothes Dryers Amend subsection 308.9.1 by adding Provision 5 to read as follows: $. In all buildings exceeding three stories in height, clothes dryer exhaust systems must be designed and sealed by a registered Professional Engineer or Architect. CHAPTER 4 REFRIGERATION 404 INST/~LLATION REQUIREMENTS Amend subsection 404.1.1 to read as follows: 404.1.1 Foundations and supports for condensing units or compressor units shall be of substantial construction sufficient to support the load. When used, wood exposed to the weather shall be pressure treated or approved wood of natural resistance to decay in accordance with the Collier County Building Code. All condensing units mounted on a roof or any other location subject to movement by winds or other forces must be' tied down at two corners with a minimum of 20 gage hot dipped, galvanized strap or other method approved by the Mechanical Official. CHAPTER S DUCTS AND DUCT SYSTEMS 504 DUCT CONSTRUCTION AND INST]tLLATION Add subsection 504.10 to read as follows: 504.10 Closure System The closure system must have an approved listing and shall be used in accordance with the listing and the recommendations of the board manufacturer. ~05 FLEXIBLE AIR DUCT CONNECTORS $05.1 ~eneral Amend subsection 505.1 by adding Provision 5 to read as follows: (2) 5. Ail flexible ducts shall meet UL181 Class 1 duct specifications and shall be so labeled. All horizontal runs of flexible ducts shall be supported a minimum of every three (3) feet. All vertical runs of flexible ducts shall be supported a minimum of every six (6) feet. All connections of flexible ducts, plenums, trunks, systems or mixing boxes shall use a mechanical connector and shall be air tight. When Class i flexible ducts are installed in accordance with the above specifications there shall be no length limitation. 509 PLENUM CHAMBERS · Add 509.3 to read as follows= 509.3 All supply and return plenum chambers shall have a minimum clearance of 4" on all sides for accessibility. CHAPTER 6 PIPINQ 603 CONDENSATE DRAIN PIPING Add subsection 603.6 to read as follows: 603.6 Insulation All condensate lines, except emergency pan drains and blow through units, shall have a trap in line. The line must be insulated to prevent condensation. Schedule eighty (80) PVC pipe may be used without insulation. SECTION THREE: REPEAL Collier County Ordinance No. 89-79 is hereby repealed in its entirety as of the effective date of this Ordinance. SECTION FOUR: CONFLICT AND SEVERABILITY In the event this Ordinance conflicts with any other ordinance of Collier County or other applicable law, the more restrictive shall apply. If any phrase or portion of this Ordinance is held invalid or unconstitutional by any court of competent jurisdiction, such portion shall be deemed a separate, distinct, and independent provision and such holding shall not affect the validity of the remaining portion. SECTION FIVE: EFFECTIVE DATE This Ordinance shall become effective ugon receigt of notice from the Secretary of State that this Ordinance has been filed with the Secretary of State. PASSED AND DULY ADOPTED by the Eoard of County Commissioners of Collier County, Florida this ~ay of~, 1991. Chat~an ApprOved as to fo~ ~f~eta~ of~ate's Offl~ ~ Assistant County Attorney ~~ ~. STATE OF FLORIDA COU~'n' OF COLLIE~ I, JAMES C. GILES, Clerk of Courts in and for the Twentieth Judicial Circuit, Collier County, Florida, do hereby certify that the foregoing is a true copy of: Ordinance No. 91-60 which was adopted by the Board of County Commissioners on the 25th day of June, 1091, during Regular Session. WITNESS my hand and the official seal of the Board of County Commissioners of Collier County, Florida, this 27th day of June, 1991. JAMES C. GILES . " Clerk of Courts and ClerlCx,%~%:,[3 ~, Ex-officio to Board of ,N' ". .~, County Commissioners ..~' ·'..~. Deputy Clerk