Ordinance 95-20 ORDINANCE 95- ~Q COLLIER COUNTY STRUCTURAL/BUILDING AND HURRICANE CODE ORDINANCE AN ORDINANCE ADOPTING THE 1991 EDITION OF THE STANDARD BUILDING CODE AS PUBLISHED BY ~{E SOUTHERN BUI LDIN~CODE~ .~ CONGRESS INTERNATIONAL, INC. WIT}{ LOCAL AMENDMENTS~ PART ONE OF SECTION ONE AND REPEALING ORDINANCE NO. 92-70, AS AMENDED; ALSO REPEALING ORDI~NCE NO. 93-62 IN ITS ENTIRETY; PROVIDING FOR CONFLICT ~ SEVERA~ILITY; PROVIDING FOR INCLUSION 1NTO THE COUNT'~ CODE; ~ PROVIDING FOR AN EFFECTIVE DATE. ~ WHEREAS, Chapter 125, of the Florida Statutes, authorizes the Board of County Commissioners to adopt a building code, and WHEREAS, Section 553.73 (1)(a), Florida Statutes requires local governments with building construction regulation responsibilities to adopt a building code covering all types of construction, and WHEREA~, the State of Florida has adopted the 1991 Edition of the Standard Building Code and the American Society of Civil Engineers Standard 7 (ASCE-7) pertaining to buildings and structures as the minimum state building code. WHEREA~, previous editions of this Ordinance were called the · COLLIER COUNTY CONSTRUCTION CODE." NOW T}{EREFORE, BE IT ORDAINED BY T}{E BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY FLORIDA THAT: SECTION ONE ~ The "Standard Building Code 1991 Edition" including Appendices A, C, and M, are hereby adopted by reference as the "Collier County Structural/Building Hurricane Code" to protect the health, safety, welfare, common interest, and convenience of the citizens, visitors and residents of Collier County, Florida. The following text is hereby deleted from Section One of Collier County Ordinance No. 92-70, as amended: "The Standard Building Code 1991 Edition including Appendices A, C and M." Also delete therefrom the text in lines 6 through 11 as follows: "...as published by the Southern Building Code Congress International, Inc., as amended herein, is hereby adopted by referenced au the Collier County Construction Code to protect the health ~afety, welfare, common interest and convenience of the citizens, visitors and residents of Collier County, Florida." SECTION TWO~ AMElqDMEh'ZS TO STANDARD BUILDING CODE The "Standard Building Code, 1991 Edition", including Appendices A, C, and M, is hereby amended, as indicated by strike throughs and underlines, as follows: CHAPTER I ADMINIS~'RATION Chapter I is omitted in its entirety. Refer to the Collier County Building Construction Administrative Code for administration of this Code. All references to Chapter I shall be interpreted to mean the Collier County Building Construction Administrative Code Ordinance No. 91-56, as amended or superseded. 1 "Words =truck '~ ...... are deleted; words underline~ are added COI. LIER COUNTY ItTRUQx'UKAL/BUILDING AND HURRICANE CODE ORDINANCE CHAPTERS INDEX C}5~a71'ER I ADMINISTRATION i CHAPTER 2 DEFINITIONS 7 CI{APTER 5 SPECIAL OCCUPANCY REQUIREMENTS 8 CHAPTER 6 CLASSIFICATION OF BUILDINGS BY CONSTRUCTION 8 CHAPTER 7 FIRE PROTECTION 8 CHAPTER 8 APPURTENANCE REQUIREMENTS 10 CI4APTER 9 SPRINKLERS, STANDPIPES AND ALARM SYSTEMS 10 C}[AFTER 11 MEANS OF EGRESS 10 CHAPTER 12 MINIMUM DESIGN LOADS 12 C}{APTER 13 FOUNDATIONS 18 CHAPTER 17 WOOD CONSTRUCTION 21 CHAF~'~:K 21 SAFEGUARDS DURING CONSTRUCTION 21 ~R 30 FIRE DISTRICT 22 2 · Words ee~-ee~--~4~ are deleted; words underlined are added." COLLIER COUNTY STRUCI'GRAL/BUILDING AND hURRICANE CONSTRUCTION ORDINANCE INDEX 508 Accessibility for the Physically Handicapped 1205.17 Aluminum Structures/Screen Enclosures 18 709 Architectural Trim, Balconies, Bay Windows 9 702.1,6 Automatic Fire Suppression System 610 Buildings Located on the Same Lot 3002 Building Restrictions 22 709.4 Chickee 9 1205.15 Component Sy.tems 18 1302.5 Concrete Footings 20 1302.2.1 Concrete, Masonry or Timber Footings 19 202 Definitions 7 1113 Doors 12 813.1 Electrical Safety 10 1205.8.1 Exterior Walls and Beams 12 3001 Fire District - General Provisions 22 507.9 Fire Extinguishers 8 1302 Footings and Foundations 19 1205.7 Foundations 12 1205.11.1 Gable Ends/Roof Sheathing 14 702 Interior Wall/Partition Fire Separation 1205.8 Masonry Construction 12 1205.16 Metal Buildings 18 1205.14.3 Metal Roofs 17 1302.2.3 Natural Solid Ground or Piles 19 1205.4 Other Structures 18 3 "Words ~ are deleted; words underlined are added." 1114 Ramps 1205.9 Reinforced Tie Beams 1708 Roof and Ceiling Framinq 21 1205.10 Roof Construction - Rafters 13 1205.14 Roof Coverings 16 1205.14.4 Roofs General 18 2101.9 Safety Requirements During Construction 21 1205.14.1 Shingle Roofs 16 1105 Special Exit Recruirements 10 1108 Stairway Construction 11 902 Standpipes 10 813 Swimming Pool Enclosures 10 719 Thermal Insulation Materials 10 1205.9.2 Tie Beam and Columns 13 1205.14.2 Tile Roofs 17 1108.3 Treads and Risers 11 706.9 Treated Palm Fronds 9 1205.11 Truss Design and Attachment 14 1205.12 Windows and Doors 15 1205.13 Wood Construction 15 1707 Wood Construction - Vertical Framing 21 706.6 Wood Shingles and Shakes S 4 "Words ~ are deleted; words underlined are added." DRAWING AND TABLES INDEX Standard Gable End Roof Sheathing Attachment IS-i Standard Drop Gable End Sheathina Attachment IS-IA Standard Gable End Wall Detail IS-2 Drop Gable End Wall Detail ISo3 Typical Attachment To Wood Frame End Wall ISo4 Typical Attachment to Concrete End Wall IS°5 Typical Ladder Detail ISo6 TYPICal DrOP Gable Detail IS-7 Gable End Bracing ISo8 Gable End Bracing IS-BA Typical Sidewall Section IS-9 Frame Wall Comer Detail IS-10 Frame Garage Door and Comer Detail IS-11 Ra~ter Framing IS-12 8" X 10" Concrete Beam Span IS-13 8" X 12" Concrete Beam Span IS-14 8" X 16" Concrete Beam Span IS-15 8" X 18" and 8" X 20" Concrete Beam SD~a~ IS-16A Stirrup Spacing IS-16' Conventional Roof Framing Uplift Load per Rafter IS-17 Conventional Roof Framing Horizontal Load per Rafter IS-IS Shearwall Detail IS-19 Window Bucks for Masonry ODenines IS-20 L)oor Bucks for Masonry Openings IS-21 Truss Desiun for Open Lanais/Porches IS-22 5 "Words ee~ are deleted; words ~ are added." COLLIER COUNTY STRUC"TURAL/BUILDING ,'~N'D HURRICANE CODE EXHIBITS EXHIBIT A Monolithic Foundations EX}{IBIT B Natural Solid Ground or Piles EX/4IBIT C One & Two Family Monolithic Footing (One Story Residence) EXI{IBIT D One & Two Family Monolithic Footing (Two Story Residence) EX}{IBIT E Stemwall Footing (One Story) EX}{IBIT F Stemwall Footing (Two Story) EXHIBIT G Boring and Notching - Exterior and Bearing Walls EXHIBIT H Boring and Notching - Non-Bearing Walls 6 "Words e~e~e~=~ are deleted; words underlin~~ are added. CHAPTER 2 DEFINITIONS 202 DEFINITIONS Amend Section 202 by addinq th,: tolt,,wi:l,s q,.:!n-' "A" ZONE A flood zone ,~ establi::hed by :h.~ Emergency Management Agency (FEMA) CANOPY A roof-like ~tructure pro)ecting t~'om .m wa~L cr supported on columns or pillars. Building roof ::Vstems project more than three (3) feet past the ex[erior wall Are considered canopies by this ordinance. CHICKEE A Seminole and Miccosukee word for house (home) used today to identify an open-type tropical structure generally used as an exterior roofed recreational area. (See subsections 706.9 and 709.5) MINI-STORAGE The use of a building divided into storage compartments. These units or compartments are for dead storage only. These units shall not be occupied for business purposes. Telephones are prohibited and only minimum electrical sop;ice is allowed, limited to a switched fixture for lighting electrical receptacles are not permitted. Plumbing for individual units is prohibited, but may be required for the overall complex, The storage unit or compartment shall not exceed 200 square feet. ONE (1) NOUR PROTECTED - Construction in which the fire resistance of the major structural members is attained by the nature of the product (Type I & II), the size of the members (Type III) and/or the protection of the members by coating, wrapping or isolating with a fire resistant material. (See SBC Section 1003, Fire Resistance References) PORC"H - A roofed platform forming the entrance ~o a house. SPECIALTY ENGINEER A Florida Registered Professional Engineer, not the Structural Engineer of Record, who undertakes the design of structural components or structural systems for a specific project. The Special~y Engineer will generally fall into one of these three categories: 1. An employee or officer of a fabricator. 2. An employee or officer of an entity supplying components to a fabricator. 3. An independent consultant. STAIRS - Means three or more risers. "V" ZONE - A flood velocity zone as established by Federal Emergency Management Agency. Coastal High_Hazard Area, 202 DEFINITIONS Amend the following definitions to read as follows: BUILDING OFFICIAL - See Administrative Code for definition of · Building Official". STRUCTURE - Anything constructed, erected, assembled or built, which requires a fixed location on or in the ground, or is attached to something by any means having a fixed location on or in the ground. 7 "Words e~ are deleted; wordn under.~ are added." CHAPTER 5 SPECIAL OCCUPANCY REQUIREMENTS 507.9 Fire Extinguishers Amend subjection 50'1.9 ~:O r,,.Id ,m;; :.~ll,~w:~: Fire extinguiuheru uhall be provided Ln the National Fire Protecti3n As~eciatLon (NFPA), relating to portable fire extinguishers, 508 ACCESSIBILITY FOR T}{E PHYSICALLY }{ANDICAPPED A~nd acct~sn 508 to rcad Florida ......... ~ ..... 553 _r the Florid= "---~ -~ "--:'~ adoFtca as ~=rt cf this ordinancc. Sections 553,501 through 553,513, Florida Statu~es, the "Florida Americans With Disability Act of 1990", are hereby adopted and incorporated herein by reference. CHAFTER 6 CLASSIFICATION OF BUILDINGS BY CONSTRUCTION 610 BUILDINGS LOCATEaj ON THE SAME LOT Amend section 610 by adding the following exception: EXCEPTION~ One story buildings used exclusively for mini-storage located on the same lot may use the requirements of Table 600. The horizontal separation will relate to the distance between buildings rather than property lines or assumed property lines. CHAPTER 7 FIRE PROTECTION 702 INTERIOR WALL AND PARTITION FIRE SEPARATION REQUIREMENTS Add subsection 702.1.6 to read as follows: 702.1.6 AUTOMATIC FIRE SUPPRESSION SYSTEM ALTERNATIVES: When an approved automatic fire suppression system is installed when not a requiremen~ of Table 400 or other portions of this Code or other ordinances or laws, and supervised in accordance with Section 901,8, a fire resistance rating for exit access corridors within a tenant space is not required in occupancy Class B, F, M, and S. In occupancy Class A, I (unrestrained) and R, the corridor enclosure walls and dwelling unit separation walls which are also corridor walls shall have fire resistance rating of not le~s than 1/2 hour, with 20 minute doors, constructed tight to the underside of the ceiling directly above. 706 ROOF COVERINGS 706.6 Wood shingles and Shakes Amend subsection 706.6.1 by adding the following exceptions: EXCEPTION~ All multi-family (triplex and above) using wood shingles or shakes shall use Class "C" or better fire resistant wood shingles or shakes unless restricted by other code requirements. EXCEPTION~ Group housing projects consisting of single-family units or duplex units with units or buildings less than 15 feet apart must use Class "C" or better fire resistant wood shingles or shakes unless restricted by other code requirements. Add subsection 906.9 to read as follows: 8 "Words ~ are deleted; words underlipqd are added." 706.9 TREATED PALM FRONDS 706.9.1 All palm fronds and/or tee,is, ,:tc, :u;e,~ lr;r ':;; ';,~.~; and chickee type structures shall be l. reat,3d with .~n .,:~prcv.,d fire retardant treatment material. The tire treatment shall cause the treated fronds, e~c., self-extinguish when the test torch is removerS. EXCEPTION, Palm fronds and/or reeds for roofs seed not be treated on chickee structures on a lot zoned for single family when distances to property lines and ocher buildings are maintained at ten (10) feet or more. 706.9.2 Frond and or reed roofs shall not be installed on structures other than open chickee structures, unless the roof system has been tested and approved in accordance with Section 706 of this Code. (See Section 709.4 of this Ordinance for additional requirements) 709 ARCHITECTURAL TRIM, BALCONIES, BAY WINDOWS Add subsection 709.4 to read as follows: 709.4 Chickee 709.4.1 Permits are required for all chickees. The permit costs are as provided within the building permit fee resolution which is currently Resolution No. 91-642. 709.4.2 Site and Building Plans are required for review and approval of permits. 709.4.3 All chickees shall be free standing structures and shall comply with the Collier County Land Development Code Ordinance No. 91-102 as amended or superseded, for requirements concerning the distance between structures. EXCEPTION, A chickee adjacent to and appearing to be part of another building shall comply with all of the following: a. Be separated from the building by not less than a one (1) hour protected or one (1) hour rated construction with protected openings, this includes window and door openings. b. The roof shall not extend above the adjacent exterior wall. (See subsection 706.9 of this Ordinance for additional requirements.) 719 THERMAL INSULATION MATERIALS 719.2 Concealed Insulation Add subsection 719.2.3 to read a~ follows: 719.2.3 Blown insulation is not permitted in vaulted ceilings which exceed a 3/12 pitch. CHAPTER 8 APPURTENANCE REQUIRI~4ENTS Add section 813 to read as follows: 9 · Words eee~ are deleted; words underline~ are added." 813 SWIPING POOL ENCLOSURES Swimming poolr~ shall cc~mply with the r,aquLrr:m,.Ivl:: .f ',Ll County Ordinance No. ')3-66 ~7 2~ as amervled ~,r 813.1 ELECTRICAL SAFETY Electrical bonding of pool parts and enc[osur,,s =~hai[ accordance with 680-22 and electrical grounding :~hall be accordance with 680-24 of the National Electric code ,~u adopted by Collier County Ordinance No. 91-62 as amended or superseded. At least one 120 volt convenience receptacle protected by a ground-fault circuit-interrupter, shall be ~rovided for each permanently installed pool, between 10 and 20 feet from the inside face of the pool. CHAPTER 9 SPRINKLERS, BTA~DPIPES AND ALARM SYSTEMS 902 STANDPIPES 902.3 Standpipes Required Amend subsection 902-3.1 by adding subsection 902.3.1.1 to read as follows: 902.3.1.1 All buildings three stories in height that do non have a Class III standpipc system shall have a Class I dry standpipe. EXCEPTION~ A Class I standpipe shall be permitted in basements equipped with an approved automatic sprinkler system. EXCEPTION: A Class ~ dry standpipe shall not be required to have a hose valve on a floor, which does not have a common element area (i.e., elevator lobby, corridor, public balcony or porch). 902.6 Btzndpipes During Construction Amend section 902.6 to read as follows: Refer to NFPA Standard 14, Chapter 9; referring to Standpipe Installation in Buildings Under Construction. This standard is adopted as part of the Collier County Fire Prevention Code, Ordinance No. 86-54 as amended or superseded. CHAPTER 11 MZANS OF EGRESS 1105 BPECIAL EXIT R~QUIREMENTS 1105.4 Emergency Egress Openings Amend subsection 1105.4.1 to read as follows: 1105.4.1 In any dwelling or living unit of two or more rooms, every bedroom and living area shall have either a second means of escape, such as emergency egress openings or alternative protection. The second means of escape or alternative protection shall be one of the following: 1. A door, stairway, passage or hall providing a way independent of and remote from the primary means of escape, of unobstructed travel to the outside of the dwelling at street or ground level; or 2. A passage through adjacent non-lockable spaces independent of and remote from the primary means of escape to any approved means of escape; or 3. An approved outside window or door operable from the inside without the use of tools providing a clear opening of not less than 20 inches (50.8 10 · Words et~fek--t~t~ are deleted; words underliD~d are added." fn width, ~,I inche~; ,6I .':n) :l, h,.,.mnr ,t:.: .'~ 5qua re le~r f. 51 no|. m) i n at, .4. rh.. ! ....... : ' :- ' opening ~ha[l not be mot,! th.,, .14 ,::,;h.':; :L2 "n off the fl~r. Such means ol .~s,r. lp,~ .;h.iL1 acceptable a) The window is within 20 t,!et l,,.i or b) The window is directly accessible to Lfre department rescue apparatus as approved by the authority having jurisdiction; or c) The window or door opens onto an exterior balcony. 4. The bedroom or living area shall be separated from all other parts of the living unit by construction having a fire resistance rating of at least 20 minutes and shall be equipped with a door that will resist passage of fire for at least 20 minutes, and is designed and installed to minimize smoke leakage. A means of providing smoke venting and fresh air to the occupants shall be provided. · XCI)TIONNO. 1~ A second means of escape or alternats protsction is not required a) The bedroom or living area has a door leading directly to the outside of the building at or to grade level; or b) The d~elling unit is protected throughout by an approved automatic suDervised sprinkler system in accordance with NFPA Standard 13, "Standard of the Installation of Sprinkler System" or for building four stories or less in height NFPA 1JR or in One and Two Family Dwelling and Mobile Homes NFPA 130. IXC~)TIOI( NO. 2~ Existing approved means of escape may be continued in use. ll0B STAIRWAY CONSTII~CTION ll0B.] Treada and Risers Add subsection 1108.3.1.1 and 1108.3.1.2 to read as follows: 1108.].1.1 Stairs shall be in accordance with the above subsection in its entirety, or shall meet the requirements of NFPA Standard 101, Life Safety Code, Section 5-2.2.2, Types of Stairs. 110~.].1.2 Only one of the above stair design standards will be permitted in a structure or building. 1113 DOORS 1113.5 Special Doorway Requirements Add ~ubsection 1113.5.3 to read as follows: 1113.5.3 Hinged shower doors must swing out. 1114 RAMPS 1114.3 Ramp~ for the Physically Handicapped Delete 1114.3 in its entirety. The Handicapped Accessibility Requirements in Chapter 553, Part V, Florida Statutes, are incorporated herein add ar~ a P~rE hereof. 11 "Words ~Peek--~bTeue3h are deleted; words underlined are added.' CI~PTER 12 MINIDftlM D~S~G'N LOADS ~ECTIOW F~Z. A~ENDMES~T TO ~CTION 1205 WIND LOAD~ O~ CHAPT~ 12 MIN"ID~D~ DESIGN LO~M3~ O~ COLLIER COUNTY ORDINANCE ~0. Section 1205 wind Loads of Chapter 12 Minimum 13es~qn l~.~ds Collier County Ordinance No. 92-70 and No. 9]-62 is ,~menrl,~d follows: 1205.7 -FOUNDATIONS All floors supported by beams & columns such as p~les or piers shall require engineer or architect design and certification. 1205.8 o HASOI~RY CONSTRUCTION 1205.8.1 o Exterior Walls and Beams 1205.8.2 o Exterior walls constructed of masonry units shall not less Chat a nominal thickness of 8 inches. In hollow masonry unit construction, unit cells shall be reinforced with at least one No. 5 bar at all comers, poured solid with concrete. Such reinforcing shall be properly anchored into the footing and tie beam. (1) All 8" block masonry walls with openings greater than six feet shall have a ~5 vertical bar at each side of opening. (2) Openings S'-0" or greater shall require 2-~5 vertical bars at each side of opening 2 cell~_~. (3) All vertical dowels shall be embedded into the concrete foundation to a minimum depth of 8J~ 7". (4)Dowel shall have a 6"°90 degree bend. (5) All block cells where verticals are placed shall be filled with a minimum of 3,000 lb. per square inch concrete mix. (6) Dowels shall be provided in the foundation where vertical reinforcement is required. (7} Reinforcemen~ bars shall be minimum grade 60. Minimum lap splice is 48 Bar diameters. (8} Horizontal masonry reinforcement is required in all block masonry walls over le c=urzzz 10'0" high. (9) Where required, horizontal reinforcement shall be placed at every third course, {10) Eight inch block masonry walls shall not exceed 8'-0" feet in length without vertical reinforcement. (11} Walls in all buildings of non-reinforced 8" hollow masonry units shall not exceed 96square feet withou; approved vertical and horizontal supports. 1205.9 - REINFORCED TIE BEAMS All formed reinforced concrete tie beams shall be constructed in accordance with IS, 13, 14, 15 and ISA. Interrupted tie beams recuire the block cells to be filled with poured concreCe two cells back from the ooint of termination and cells shall be r~inforced with I #S bar. extendinQ fJ~om the footing steel to the tie beam steel. All beams exceeding span table limitations in IS-13, 14, 15, ~j~ and 16 shall be designed and sealed by an architect or engineer. 1205.9,1 - An optional bond beam with procast lintels shall permitted in lieu of a formed tie beam. Only an approved engineered bond beam system will be permitted. Completed work sheets indicating calculations of uplift requirements on the beam and load calculations for the protest lintels must accompany the permit appZication or appear on the drawings. 12 'Words eth--uek--~hi-et,gh are deleted; words underlined are added." Nots: Other Co~li,~r County Ordiuanc,,~ ;~,J,lre::::;n'l ',~:.':',' "':'- are: the Flcod OrdLnar~ce and ~h,~ Co.'~:;tat t~uLl,l~n'~ Ordirlancc. <I) R,~nforced tie b.,Jm ::hn[l be I,i, .... l ,: ,,;n': "'. perimeter at each floor .and rook [ev,TL or1 ,~xL,,tl',{ ',/.a, masonry 1205.9.2 TIE BEAM AND COLUMNS (1) Block gabls ends shall be a maximum without intermediate tie beams. (2) All structural columns supporting roof truss,~s spanning more than 30' or where the vertical Loads are 5,000 lbs. or more mus~ be designed by an engineer cr architect or have product certification. (3) Minimum size block columns shall be 8"x12" with four ~4 reinforcement bars tied with #2 ties 8" on center from looter to tie beam. (4) Minimum cast concrete columns shall be 8"X8" W/4 #4 bars and ~2 ties · 8". (5) All columns shall be designed for uplift as well as vertical and horizontal reaction loads. (6) All tie beams shall require a minimum of two outside corner bars with a minimum lap of 24" for bars of 5/8" diameter or less. Bars greater than 5/8" shall be lapped a minimum of 40 bar diameters or require lap splice as designed by an engineer or architect. ~20~.9.3 - In solid masonry unit construction, the tie beam shall be anchored to the footing in an approved manner. 1205.10 - ROOF CONSTRUCTION - RAFTERS Where conventional wood framing is ~ used. rafters and ridge beams must be sized to accommodate all assigned roof and reaction loads to resist winds of 110 MPH. (1) Sizing of rafters must be in accordance with National Forest Products Association Span Tables. (la) Rafter sizing must take into account wood species and grade of lumber. (2) Rafters, spans, spacing, uplifts and horizontal loads are provided on attachment IS-17 and IS-18 respectively. (2a} Design parameter for attachment ~S-17 and IS-18. (a) Wind VelocitV - 110 MPH (b) Exposure Category - C (cl Building Category - I (d) Force Coefficients - Enclosed Building {e) Tributary Area - 32 SF (f) Roof Slopes 2/12 - 7/12 (10~ - 30~) (g) Mean Roof ~eight - 12 Feet (h) Roofing Shingles Two Foint Bearing (3) Collar tie~ are required on every rafter a~ ~he upper third of the roof. (See ~S 12) (4) Minimum size ridge board shall be no less in depth than the cu~ end of the rafters attached to it and no less than 2' E~L~/3al in thickness. (S) All such members shall be securelV fastened to the exterior walls and ridge with approved hurricane anchors or clips. 13 "Words eee~e~-e~are deleted; words underline~ are added." 1205.11 TRUSS DESIGN AND ATTACHMENTS (1) Where trusses arc :;~ann~ng ~rc ~an 30" :~ over exterior walls and finally resting ,,n beam, the exterior wall must be desiqne~] as., kre~r~n7 w;~l to support the trusses. Foundat[on ~oot,~rs will required. Trusses shall be designed with bearing. All beams shall be designed to ,,cc~mc':.~e loads. ExceDtion~ When the soan between the exterior beam and wai~ less than 7 feet. the trUSSes m~y b~ Can~i~vered .~ff ~h~ exterior w~ll. When the exterior wall cannot be us¢~ for bc~rinq dU~ ~Q fixed ~lass or openings. the trusses shall be built in two sections. carried bY a ~irder/dra~ strut. extending from th~ ceiling to the roof sheathin~ over the exterior wall. The wall or ulass below shall be attached to the ~irder to resist all horizontal wind loads. See IS-22 cxtcn~c~ over exterior walls and f~nally rcstin~ Dn an ..... ~" ~ .... ~' exterior ~all must footors ~ill be rcq-~Ircd. T.--uzsc~ shall bc ~h =hres pclRt ~carlng. ?.II beam; ;hall bc {2} 111 Attachment of trusses to beams shall be anchored to accommodate all assigned uplifts, reaction and horizontal loads. (3) /21 Anchors and straps shall be installed per manufacturers specification. (4) (3} Gable exterior zones shall be identified by truss manufacturer. See Exterior Zone Nailing Schedule attachment IS-1. '~ (4) Minimum design load for trusses shall be as follows: TLL - 20 PSF TDL - 20 PSF BLL - 0 PSF BDL - 10 PSF (C) /5! Dell. LiveLoadL/360. (7) (6) Duration loading factors of 25% for gravity and 33% for wind may be applied. 1205.11.1 - GABLE ENDS/ROOF SHEATHING (1) See attachments IS-1 thru IS-8 for nailing and bracing gable ends. (2) Exterior end walls on wood framing adjacent =o a cathedral ceiling shall be balloon framed. See IS-SB (3) Minimum roof sheathing shall be I/2~ 15/32" four-ply, CDX exterior plywood or 15/32 OSB. (4) Power driven hailers shall use anti-penetration devices. (5}T-nails, D-nails and staples are prohibited. (6) All sheathing shall be nailed with SD common nails at six inches on the edges and twelve inches in the field maximum. See Attachment IS-6. (7) Truss overhangs four feet or greater shall be glued and nailed with minimum 8D nails 4" S.C. edge and field. Glue shall be a waterproof panel adhesive. 14 "Words struck ~u ..... u are deleted; words Under~in~d are added" 1205.12 WINDOWS A/~ DOORS All unprotected exterior window:: .,n,i rated and labeled for 110 M[,H wiud For w~ndow and door buc~ fr,[ m. ir:r~T'y~r~ir:~L[.__:.. IS-20 and 21. .......... rcquircmcnts cf ~ECE 7, 2, r=tcd hurricane zhuttcrn z=h~[[ (3) [2} Garage doors shall be designed [or 110 MPH wind load, design shall comply with SBC 1205 or ASCE-7. The more restrictive shall apply. [~ (3) Retrofitring of all unprotected openings on existing structures shall require an engineer or architect design and seal. All components of design including attachments shall comply with SBC 1205 or ASCE-7 110 m.p.h. wind loading requirements. 1205.13 - WOOD CONSTRUCTION 1205.13.1 - Openings shall be a minimum of 3'0" from all comers or be designed by and engineer or architect, or COmPlY with IS-11. (1) Windowa e~ in gabled end walls shall be no more than a nominal 3'-0" in width and multiple windows shall be separated horizontally by not less than 3'-0" unless engineered and certified. 1205.13.2 - Bottom plate shall be anchored with galvanized bolts or approved mud anchors maximum 4'-0" o.c. (1) U-Strap anchor shall be fastened onto stud maximum 4'-0" apart top, bottom plates and adjacent to all openings. (2} If truss span exceeds 20'-0", strap is required on all studs top and bottom or u-strap 4 it, apart top and bottom plates and adjacent to all openings. Bearing and exterior walls onlv~ {3)Comers shall be strapped braced. See drawing #ISll. 1205.13.3 - Fasteners and connectors shall be galvanized. From the coastline to 3.000 feet landward, including U.S. ~I and all barrier islands, connectors shall be either {1) hot dipped galvanized, coated with 1.5 ounces of zinc per one square foot of steel, (2) triple zinc coated under ASTM Ag0 Triple Spot Test, or (3) stainless steel, or (4) painted during or after installation with one of the following: (a) Epoxy-Polyamide Primer (SSPC-Paint 22) (b) Coal-Tar Epoxy-Polyamide Black or Dark Red Paint (SSPC-Paint 16) (c) Basic Zinc Chromate-Vinyl Butyral Wash Primer (SSP-Paint 27) and cold applied Aspbaltic Mastic {Extra Thick Film) paint (SSPC-Paint 12) Note: All coatings are to be brush applied to the embedded plates at the jobsite during or after truss installation. 1205.13.4 (1} All attic access must be swingdown type hinged with edges overlapped on bottom cord of trusses. 15 "Words e~ are deleted; words underlined are added." ------ m I wiuh outswlnq vaneIs or door, Thq ~uooorCed on all edqes to oreve~t 1205.13.5 - Bearinq waX1 headerg shall be architect or an enqineer Lf the hutldinq wtd;q .,x-.-e,Lz: !3' . (1) No concentrated loads greater than S,O00 Ibs. :;hall occur over openings without design certifLcation. (2) Beams shall be anchored to co[umns or walls and the columns and walls shall be anchored to the foundation to accommodate all truss uplifts, reactions and horizontal loads. 1205.13.5 Premanufactured beams hav~Dq a gurr~n~ SBC ~oDrova~,. 1205.13.6 - All structural sheathing shall comply with SBC Table 1706.6 A. (1) Approved structural sheathing shall be applied to all wood framed walls minimum thickness of ~x~. 15/32" 4 DIv or 15/32 OSB 16" stud spacing and '~ 15/32, for 24" stud spacing. Sheathing shall be applied directly to studs. (2) Wall sheathing shall be nailed 6" s.c. on edges and 12" s.c. in field. See shearwall detail IS-19. 1205.14 - ROOF COVERIN~ This section is in addition to section 706 Roof Coverings and Chapter 32 Installation of Roof Coverings. Where conflict is apparent, the greater requirement shall prevail. 1205.14.1 - SHINGLE ROOFS The following specifications for nail sizing are based on the use of ~/~ 15/32 inch 4 ply COX plywood or 19/33 15/32 OSB. (1) Thirty lb. felt ASTM D-226 minimum. Dry in with 2" 4-~ minimum lap. (2) Metal or olastic tab type nail 7/8" minimum length with round heads or tin tabs minimum size 15/8" diameter 32 gauge nailed with roofing nails not less than 7/8" in length. (3) Nail spacing on dry in 12" 6a~ on lap and 18" 12~ o/c stagger nailed. (4) Save drip, minimum 26 gauge galvanized or equivalent gauge in aluminum or copper with 3" lap nailed 6" o/c with overall girth not less than 5" 6~ with minimum face of 2". or less if enQineer aDDroved. (5) Roof vents to be minimum 26 gauge galvanized or .024 aluminum or equivalent in copper. ~f~4-//zL Minimum grade shingle shall be a Class "A" 25 year with a minimum weight of 230 lbs. per 100 square feet. {~) (7} Nail all shingles with ~ 6 nails per shingle, minimum length I 1/4" with 3/8" head. On shingle over existing installations, minimum length 11/2" {Ty (8). Plastic cement ASTM D-2822 minimum on all saves rakes, gable ends and valleys 6" in from edge, on too of ~etal. 16 "Words struck ~~ ..... u are deleted; words underlined are added." ~e} LgJ Valley metal minimum width IS", ;:6 ,.,u,;,! :l.'.' ,:;;-:. : minimum or equivalent qnugR [n (1Q} Ridge vents nailed 6" o/c ,u~d approved tVpe nail. (11] All fixture pieces. hiD. and riHqe have aDDroved shingle adhenive 1205.14.2 - TILE ROOFS (1) 30 lb. felt ASTM D-226 minimum, dry minimum lap. All ~90 lb. granulated roofs to be back nailed 12" spacing on lap regardless of pitch. The head lap must be a minimum of 2". (2) Metal or plastic tab type nail 7/8" minimum length with round heads or tin tabs minimum size 15/8" 32 gauge nailed with roofing nails not less than 7/8" in length. (3) Nail spacing on dry in 6" on lap and 12" o/c stagger nailed in field. (4) Eave drip minimum 26 gauge galvanized or equivalent gauge in aluminum or copper with 3" lap nailed 6" o/c with overall girth not less than 5" 6-~ with minimum face of 2" or less if enQineer aDoroved. (5) All roofs under 5/12 pitch shall be hot mopped one layer of ~90 oranulated roll roofing over the #30 dry ~ w-i~oa 390 ASTM Type IV asphalt (minimum weight 80 lbs.) D-312 or equivalent. (6) All roofs under 5/12 to be mud set with approved mortar using a 10" mason trowel with one full trowel of mortar per tile, no nailing. (7) Roof pitches 5/12 to under 7/12 pitch can be mud set or nailed according to manufacturer's specifications. Roofs set in mortar to have ~90 lb. felt hot mopped with Type IV asphalt. (8) Roof pitches 7/12 and greater are to be nailed on battens or installed according to ranufacturer's specifications. No mud setting of tile on pitches 7/12 and greater. {9) All nailed on nile must have two nails of ~a~ufacturer approved length and type per tile or installed per manufacturer's specifications. {I0~ ~ccf vents. Sac 12OS.l~.l [e & C]) (10) All fixture pieces, hip, ridge and rake either nailed or mud set must have approved tile adhesive. (12} (11) On all tile roofs, the first row of tile must be clipped, nailed, or muddled according to manufacturer's specifications. '~' {12) When required, cold process of plastic roof cement shall be permitted to be substituted for hot asphalt for pitches 6/12 or greater. ~ (13) New products must be submitted for evaluation and approvals. 1205.14.3 - METAL ROOFS All metal roof installations to be as per manufacturer'g aDoroved specifications. [1~ ..... ' ---' ........ =h=ll .... (3) 4~Me&J~e-~'K'-4 . . 17 "Words ~ are deleted; words ~ are added." 1205.14.4 - ROOFS GENERA~ ~2~ (1} All rough in for roof fascia shall b,~ with attachment IS-9 to accommodate and attachment of the drip edge. f~ (2] Where soffitt material, (aluminum or ~t[~ec ,,pprov,~ types) is installed, each panel uha[l be attached the building or t:-uss system. Panels shall be nailed, screwed, stapled or secured with other approved fasteners. 1205.15 - COMPONENT SYSTEMS (1) Where manufactured components of exterior wall or roof systems are used, they shall be engineered and certified to withstand windloads of 110 miles per hour and comply with all building codes. 1205.16 - METAL BUILDINGS (1) Metal buildings ~ust be engineered and certified as a partially open structure unless windows, doors or other wall openings are protected wi~h doors, windows or shut~ers ra~ed to withstand 110 MPH wind loads. (2) Where additions are ~ade to existing metal buildings, engineered certifica~ion must be provided to confirm that the existing building was designed for the additional loads. (3} Where additions are to be made to existing me:el buildings that are not designed for the additional loads, the addition ~ust be designed to be structuraliV independen~ of the original building. (4) Metal building roofs must be designed to the loading of UL-90. (S) Wall panel will be held to the secondary frame with an a~achment that has a minimum bearing area of 1/2" diameter. (6) The firs~ wall purlin will be a maximum 3' above the floor. (7) Exterior siding a~tachments to the foundation must be show~ on the engineered foundation plans. {8) Base angles or tubes may not be attached to the foundation with shell fired fasteners. 1205.17 - ~J~UMINUM STRU~-~-u~ES/SCREEN ENCLOSURES (1) Aluminum structures or screen enclosures shall be engineered or comply with Aluminum Structures Manual AL-1 or Aluminum Institute Specifications. All screen enclosures ~hall h~ve screen attached wi~h a selforeleasing screen splits. Splits shall release at wind speeds of 55 to 60 M.P.~. Exception: I~em #2 not required on horizontal surfaces. 1205.4 (Yr~ER BTRUCT~IR~S Amend subsection 120~.4 to include satellite dishes. C~A~TER 13 FOUNDATIONS 1302 FOOTINGS AND FOUI~DATIONS 1302.2 Soils Investigation Amend subsections ~302.2.1, and 1302.2.3 to reed follows: 18 "Words e~ are deleted; words ~ are added." 1302.2.1 Concrete, Masonry or Timber Footings Footings ~hali be us dnsign,~d =hat th,~ 4[ l,~w;H,~,~ ~,..,r capacity of the 3oil is not exceeded. [t r;trtlctut'.m/ concrete. masonry or timber footings 4re ~mse,], th0'y :;r:.lLi '.':" on undisturbed or minimum ninety five (95) percent soil of uniform density and thickness. Compaction shall meet a minimum requirement of 95% Proctor, ASTM D-1557. In monolithic slabs a minimum of three tests shall be p>ro-/ided for buildings up to 2000 sg. ft. in area. Buildings larger than 2000 sq. ft. in area will require one additional test for each additional 2000 sq. ft. of building area or fraction thereof. In stem wall construction a minimum of three tests shall be provided for the first 300 lineal feet of footing. Buildings with more than 300 lineal feet of footing will require one additional test for each additional 300 lineal feet of footing or fraction thereof. If fill is less than 18" deep, tests shall be provided for the full depth taken at finish grade. If fill is greater than 18" deep, tests shall be provided for each 12" lift. 1302.2.3 Natural Bolid ~round or Piles Foundations shall be built upon natural solid ground. Where solid natural ground does not occur at the foundation depth, such foundation shall be extended dc~wn to natural solid ground or piles shall be used. Foundations may be built upon mechanically compacted earth or fill material subject to approval by the Building Official upon submittal of evidence that proposed load will be adequately supported. Such evidence shall be as outlined in Section 1302.2.1 above. Monolithic foundations are not permitted in the "V" Zone. Monolithic foundations may be used in the "A" Zone if the fill is 24" or less and the following conditions are met: (See EXHIBIT "B" W}{IC"H IS HEREBY INCORPORATED HEREIN) 1. All objectionable material is removed from the area to receive fill. 2. All fill material is clean. 3. All fill is installed in twelve (12) inch lifts. 4. Each lift is mechanically compacted. 5. A density test is taken at each lift and certified by a Florida Registered Engineer. 6. Density test reports identify each lift. 7. Building pad (area of compacted fill) is extended five (5) feet outside of building perimeter. 8. Angle of repose of balance of fill to toe of slope shall not exceed thirty (30} degrees from the horizontal. 9. Density test reports are given to the Building Official at rough plumbing inspection. 10. No si~nificant storm water run-off ie permitted to flow from the subject premises onto abutting properties. Reinforced masonry (stemwall) construction is required the "A" Zone if over 24" of fill is required to the bottom of the footing and any of the above ten (10) minimum requirements cannot be met because: 19 "Words ~ are deleted; words ~LqL~ad~ are added." The Finished [loot m,n;t be I>~" .,tlc~v,. paved ronct; 2. Limited aideyard ueparation [~rot~[bl:-.: w,,, ..r Monolithic foundations will be approv,?d Zone if the above ten (10) conditions Reinforced masonr/(s~emwall) construction is r~u[red outside the Flood Zone if any of the above ten 'tO) minimum requirements cannot be met because limited sideyard separation prohibits water control. (See EXHIBIT wE" & "F" WHICH ARE }{EREBY INCORPORATED HEREIN) 1302.5 Concrete Footings Add subsection 1302.5.3 to read as follows: 1302.5.3 The minimum requirements for footings for one and two family homes less than three (3) stories in height and not designed by an architect or engineer are as follows: 1. Monolithic footings for a single story residence shall be as follows: WOOD FRAME - at least 18 inches deep by 12 inches wide with two (2) #5 reinforcing bars at bottom. CBS - at least 16 inches deep by 12 inches wide with two (2) ~5 reinforcing bars at bottom. 2. A monolithic footing for a two-story building shall be at least 24 inches deep by 1~ inches wide with three (3) ~5 reinforcing bars at bottom. 3. Reinforced masonry (stemwall) footing for single story residence shall be 10 inches deep by 16 inches wide with two (2) #5 reinforcing bars at bottom. 4. Reinforced masonry (stemwall) for a two story residence must be at least 12 inches deep by 24 inches wide with three (3) #5 reinforcing bars. 5. All monolithic footings - slab systems shall be formed to the bottom of the footing. (See EXHIBIT "A", "C" & "D" WHICH ARE HEREBY INCORPORATED HEREIN) CFj~PTER -17 WOOD CONSTRUCTION 1707 '~RTICAL FRAMING 1707.7 Cutting, Notthing and Bored Holes Add subsection~ 1707.7.4 and 1707.7.5 to read as follows: 1707.7.4 Notches used for plumbing, electrical pipes, cables or wire requires a steel strap no less than 1/16 inch (1.59mm) thickness covering the notch. (See EXHIBIT "G" & "H" WHICH ARE HEREBY INCORPORATED HEREIN) 1707.7.5 Top plates in nonbearing walls may be interrupted (eliminated) between studs for the purpose of p].umbing vents (stacks), dryer vents, mechanical ducts, limited to 28 incLes maximum in any one wall, provided wall is securely anchored on both sides of cutout. 20 "Words e~ee~-~-~ are deleted; words d~LD_d3_E/i~ are added." 1708 ROOF AND CEILING FRAMING 1708.1 Roof Joists Add subjection 1708.1 o L0 tc~ r,~,ut ,~:: ~, . . .w:: : 1708.1.10 Notches used for plumbing, ,~le,:~r:'; ~i r' or wire r~quires a steel strap ot no less th,~u mm} thickness covering the notch. (See EXHIBIT "G" & "H" WHICH iS I{EREB'( iNCORPORATED HEREIN) CHAi~-~M 21 SAFEGUA~aDS DURING CONSTRUCTION 2101.9 Safety Requirements During Construction Add subsections 2101.9.2.1, 2101.9.5, and 2101.9.6. read as follows: 2101.9-2.1 Adequate sanitary facilities for the convenience of all workers shall be provided in the following ratio: Minimum of one (1) water zloset and urinal for each fifteen (15) workers. 2101.9.5 As agent of the owner, permittee acknowledges responsibility for access control and site safety at all times prior to the issuance of a Certificate of Occupancy. The permittee shall determine which ingress and safety measures, if any, such as temporary fencing, barricades, gates, signage, covered walkways and :he like, are necessary to assure public safety on or near the site of the work under his control. 2101.9.6 In the course of carrying out inspection assignments, code enforcement personnel may observe conditions contrary to federal, state and local safety standards. wherever this occurs, each case will be brought to the attention of the person in charge at the site. Code Enforcement personnel shall not subject themselves to unsafe conditions in order to perform building inspections. Such personnel shall advise the permittee of the inability to conduct an inspection; the subject inspection shall be considered as rejected and shall be rescheduled. However, if corrections are made immediately the inspection may then be continued. Where manifestly unsafe conditions are allowed to remain uncorrected, cole enforcement personnel shall direct operations in the vicinity to cease until remedied as provided for in subsection 102.2 of this Ordinance. 2101.11 Temporary Storage, Dispatching Office, Tool Shed and Plans Rooms On-site Add subsection~ 2101.11 to read as follows: 2101.11 Temporary facilities or combinations thereof, whether on wheels, skids, rounded or unfounded, shall be anchored or tied down to prevent dislocation by hurricane force winds (110 mph). Tie-doom criteria shall be in accordance ~ith the Collier County Mobile Home Ordinance No. 89-45 as amended or superseded with accompanying Department of Motor Vehicle specifications. Exception: Mobile equipment (i.e. vehicles, trailers, etc.] which is currently licensed and equipped for over-the-road use and which is positioned {unattached) and maintained in a state of readiness for unimpeded drive or tow-away in case of emergency, shall be exempt from the tie-dc'wn requirements. 21 "Words e{~ee~w~h are deleted; words underlined are added." ----- m m Tempcrary ei.:ctric service, i[ uti[ize~], :;ix,j~ [ :~.' .~:.=' : ,;:: protected to carry connected loads ::.~fel'/. :'!,Vr:!.' ~1 protection of temporary wiring shall [De ,l:i.~d Io damage to inaulation and o[her component:i. 'T'..mp'~'+~rV shall be maintained so as not to impair nafet. y Inadequate tie-downs or unsafe electrical service :~hai[ cause for rejection of any inspection of permitt,~,! work site. CHAPTER 30 FIRE DISTRICT 3001 GEr~ERAL PROVISIONS 3001.2 Scope Amend subsection 3001.2.1 to read as follows: 3001.2.1 The Fire District shall include the ~ollowing: 1. All industrial and C1, C~, C3, ~4, cS Zoning as indicated on the Official Zoning Atlas ~ Collier County, Florida. ~. Areas identified as C1, C~,, C3, C4, C5 or Industrial in a 'PUD* (Planned Unit Development). 3. All NON-C0~FOP~I~G stn~ctures identified as C1, C3, C4, C5 or Industrial. 3002 BUILDING R~TRICTION~ 3002.2 Other Specific Rec~irements Amend subsection 3002.2.~ and 3002.2.~ to read as follows: 3002.2.2 Oroup 'H' Occupancy shall be permitted in the ~ire district in accordance with Chapter 40 3002.2.~ Exterior walls of Type IV construction within 0-3 feet ~rom property line or assumed property line shall have no openings and shall be o~ two (2) hour ~ire resis~ive construction. Other exterior walls will be in accordance with Table ~00. ~PPI~'DIX C: ONE AND TWO FA/~LY DWELLI~6S Amend Appendix 'C' to read as follows: All one and two ~amil~ dwellings not ~ore than three stories in height and their accessor~ structures shall be designed in accordance with this Ordinance. (See EXHIBITS A ~RU K ATTACHED TO THIS 0~DINANCEI SECTION THREEs REPEAL OF PREVIOUS ORDINANCES Section Two of Collier County Ordinance No. 92-70 is hereby repealed; Ordinance No. 93-62 is hereby repealed in its entirety as of the effective date of this ordinance. SECTION FOUR x CONFLICT AND SEVERABILITY In the event this Ordinance conflicts with any other ordinance of Collier County or other applicable law, the more restrictive shall apply. If any phrase or portion of this ordinance is held invalid or uncons=itutional bV any court of competent jurisdiction, such portion shall be deemed a separate, distinct, and independent provision and such holding shall not affect the validity of the remaining portion. 22 "Words ee~a~k--e4~M~ are deleted; words undeFlined are added." 6EC~O31 FXVEz INCLUBXON IN T~E CODE OF ~e provisions of this O~dlnance shall become and be made a par: of the C~e of ~vs and Ordinances of Collier County, Florida, ~e sections of the O~dtnance may be renumbe~ed relettered ~o accomplish such, and the word "ordinance" may be chanqed to "sec~ion", "ar~icZe", or any o~her appropriate word. BI~ION BlZt ~1~ DATE - D~. ~is ordinance shall be ro~arded ~iChou~ delay Co the Smcre~a~ o~ S~atm~ ~ ~his Ordinance shall no~ become effective until S:00 A.M. on 3uly ~ 1995. PASSED ~D D~Y A~ED ~ the Board or County Co~isalone~s o~ Collier County, motida this ~f day or~ ~995. A~ESTz BO~ OF CO~ CO~ISSIONERS ZOA / 'O ' · .~,.., Approved as to fom ~hOmam C, Ammtmtant County Attorney 8d NNLS O 6" ON CENTER SHEATHING ATTACHED -' '-' AT ALL PANEL EDGES EXCEPT TO THREE TRUSSES MIN.. r ON GABLE TRUSS ( TYPICAL ) X OUTLOOKERS 16" ON CENTER AS REQ'D.. EXTi~IOR ./ I-,"" jj ".-, NAILS ~, "' ON CENTER MIN. ,.,- ........ :,,.--~ --- 'l ....... "" / \ "' CENTER UNE OF RIDGE "'-- ,./' X 4- SPRUCE OR BE1TER ......,:..'.:: BLOCKING AT RIDGe' ( TYPICAL ) "" ...../ ,..j~' >P GABLE END TRUSS ,_/ ..... -"':Z(..' ,~i X ¢ SPRUCE OR BETER BLOCKING END TWO TRUSS / RAFTER ; .... SPACES ( TYPICAL ) 8d NA/LS O 12' ON CENTER ON NAILS O ON CENTER MIN. PANEL EDGES AT BLOCKING INTERIOR OF PANEL ( INTERMEDb~TE ) ( TYPICAL ) z- EXCEPT ON GABLE TRUSS ( TYPICAL ) NOTE: 2 x CONT. (TYPICAL) 1. ALL NAILS TO BE COMMON NAILS MIN. 2. IF BUILDING WIOTH EXEEDS 40' O" FEET OR HEIGHT IS MORE THAN TWO STORIES lOd INSTEAD OF 8d FOR A'R'ACHMEI'~' OF ROOF' SHEATHING. ROOF SHEATHING ATTACHMENT PLAN NAILS O 6" ON CENTER SHEATHING A'FFACHED · AT ALL PANE EDGES EXCEPT TO THREE TRUSSES MIN.. ON CABLE: TRUSS ( 'PfP~C. AL ) EXTERIOR '~,,,"xl~<-"""i""':,,,-:'" · ,...,-\ -::~.- ,,,,,,... /_j '-. '-.o. ,/----,,, /' ~: ..... ...- ...../-":::--. -,,j / .,--t "- GABLE END TRUSS / ( l Z' OVERHANG ,MAX. ) ,,,, UNE OF RIDGE .....:,. BLOCKING AT RIDGE ( TYPICAL ) i"""" ~,,,,.,/2,~"' ......:>~:i !"" ..---~: ..... J/-' .,,. ...... / >,:: -,.,.,. "' :': X 4- SPRUCE OR BETER BLOCKING Z"Z~' ~'/?"'.."~ ( FLAT OR VER'nC~L ) ? :>r-:::,- ...F'...L' ,',.,o ',',,o ' --"'"' "-. _ \ SPACES ( TYPICAL NAILS O ON CENTER ;JIN. 8d NAILS O 12" ON CENTER ON PANEL EDGES AT BLOCKING INTERIOR OF PANEL ( INTERMEDIATE ) ( 'NPICAL --P_XCEPT ON GABLE TRUSS f~ TYPICAL ) NOTE: x CONT. (TYP!CAL) 1. ALL NAIt_~ TO BE COMMON NAILS MIN. 2. IF BUILDING WIDTH EXEEDS ~,0' O" FEET OR HEIGHT IS MORE THAN TWO STORIES lOd INSTEAD OF 8d FOR ATTACHMENT OF ROOF SHEATHING. ROOF SHEATHING ATTACHMENT PLAN \.... STANDARD GABLE END STANDARD GABLE END WALL DETAIL 2 X 4 GROUP 2 OR BEITER BLOCKING C'F2qltRED BENEATH SHEATltINO JOINT ATTACH BLOCKING WITH THREE 16 D TOENAn ~-D OR TW'O 16D EDGE NAn_~D 8D NAILS @ 4" O.C. GABLE END AREA ONLY EACH END SEE IS1 XXX~ qU.. 12"~IAX. J( 1/2" MIN. STRUCTURAL ROOF SHEKI'H~G. SEE IS 1 FOR NAILING WOOD TRUSSES \ AT 24" O.C. ( TYP ) GABLE END .... ~ VERT. BRACL'N( BRAChNG AS PER IS8 SEE ~ FOR DETAIL SEE IS4 FOR (2) 16D NAILS WOOD WALL AT EXTERIOR SEE IS5 FOR ZONE TRUSSES CBS WALL NOTE: OPTIONAL ( TYPICAL ) / CEILING FLrRRING / X~ NOT SHOV~N J FOR CLARITY GYPSUM WALL NOTES: BOARD com'~ous ~- x 4 SPRUCE OR B~R ~L B~CE (1) FOR CA~D~ ~GS, GABLE AT 8' O.C ~X. OR IX4 ~2 AT ~USS MU~ A~O BE CAT~D~L 16" ON CE~ER ' ~ ~ W~ BABOON ~D ~ FOLLOW S~PE OF G~LE B~ON1 TO PE~N~ B~G REQ~D BY T~.L OR ~ ~MDU~ ~USS D~GS -.--. m I DROP GABLE END WALL DETAIL 2 X 4 GROUP 2 OR BETI'ER BLOCKING CENTEKED BENPATH SKEATKINO JOINT ATTACH BLOCKING WiTH THREE 16 D 8D NAILS (~ 4" O.C. TOENAILED OR TWO 16D EDGEN~ DROP GABLE END AREA ONLY P, ACH END SEE IS1 i/2" MIN. STRUCI'URAL RO0~: s~A'n-~a. s~ \ WOOD TRUSSES AT 24' O.C. ( TYP ) GABLE END ~ VERT. BRACING BRACING AS PER IS8 SEE IS7 ~ FOR DETAIL SEE IS4 FOR NOTE: OPTIONAL WOOD WALL CErI,_rNG FURRING (2) 16D NAILS SEE IS5 FOR NOT SHOWN FOR AT EXTERIOR CBS WALL CLAR/TY I ZONE TRUSSES ( TYPICAL ) / GYPSUM WALL ~ J NOTES: BO~D comm,qJous :~x 4 s~Rucs OR BETTER LATERAl, BRACE (1) FOR CATHEDRAL CEILINGS, GABLE AT 8' O.C. MAX. OR IX4 #2 AT TRUSS MUST ALSO BE CATHEDRAL 16" ON CENTER AND END WALL BALLOON FRAMED 'tO FOLLOW SLOPE OF GABLE BOTTOM V' ALL NAILS TO BE COMMON NAILS BYT. P.I. OR TI~ INDIVIDUAL TRUSS ' IS 3 DRAWINGS TYPICAL GABLE ATTACHMENT TO WOOD FRANIE END WALL 2 X 4 SPRUCE OR BETTER LATERAL BRACE 8' O.C. WITH(2) 1613 ~ COMMON NAILS GABLE OR 1X4 ~'1 AT 16" END SKEATIIING TO BE ON CENTER WITH ,X~ NAILED WITH 8D COMMON NAILS (2) 10D COMMON NAILS ,4---' 6" O.C. @ EDGES AND · x~ 12" O.C. INTERMZEDIATE T ( TYPICAL ) ' ~ /i6D COMMON NA]]-S @ 16" O.C. . ~ 2 h'N. #10 SCREWS ... / TlZ OC 5"/. JM W,'d.L ~ 80ARD r NOT~: OPTIONAL 1X BLOCKING CEILING FUR.RING NAILED 16" SPLICE JOINT NOT SHOWN FOR O.C. W;16D BETWEEN DBL. CIARiTY COMM 0 N NAILS TO P PLATES SEE STANDARD WHEI~ CATHEDRAL CEILING BUILD IN G C O D E OCCURS AT GABLE, GABLE TRUSS FOR NAILh"qG OF MUST ALSO BE CATHEDRAL AND DOUBLE TOP F, ND WALL BALLOON FRAMED PLATES TO FOLLOW SLOPE OF GABLE BOTTOM CHORD NOTE: THIS INSTALLATION IS IN ADDITION TO BRACING IS 4 REQUIREMENTS OF 'tRUSS MANUFACTURER OR T.P.I. 85 TYPICAL GABLE ATTACHMENT TO CONCRETE END WALL 2 X 4 SPRUCE OR BETTER LATERAL BRACE 8' O.C. ~ (2) 16D GABLE COMMON NAII,S END X.~ SKEATHING TO BE OR 1X4 ~ AT 16" NAILED WITH 8D ON CENTER WITH (2) 10D COMMON NAILS COMMON NAILS 6" O.C. @ EDGES AND  ~ 12" O.C. hNTERNIEDIATE ( TYPICAL ) 16D COMMON NATLS @ 16" O.C. / G "~ WALL BOkRD NOTE: OPTIONAL CK1LINO FURRING HURRICANE NOT SHOWN FOR CLAR1TY O (} STRAP 4' O/C BEbrr UP AND 2 X 8 P.T. WTrIt 1/2" OVER GABLE "J" BOLT OR MUd. BOTTONI CHORD ANCHOR 4' O.C. OR 2X6 P.T. W/BLOCKING TO CARRY CEILING DIAPHRAGM WHEN CATI~DRAL CEILING OCCURS AT GABLE END USE DETAIL IS8 OR IS 8A NOTE: THIS INSTALLATION IS IN ADDITION TO BRACING IS 5 REQUrR~MENTS OF TRUSS MANUFACTURER OR T.P.I. 85 · . TYPICAL LADDER DETAIL ~ X 4 SPRUCE OR BETI3ER '. ~~LOCKING CENTERED BENEATH SHEATHING ~[OINT. ATTACH BLOCKING ( 2 ) 16D NAM,S EACH W/( 3 ) 16I) TOENAn-ED OR LADDER EACH SIDE ( 1 ) 16D ENDNAILED BOTH 30 LB. FELT OVER ENDS. 15/32" MIN. SKEATHING NAILS AT i 6" O.C. DRIP 8D NAILS @ 1 X 4 LADDERS SPRUCE EDGE AND 4" O.C. MIN. OR BETTER 14" O.C. 4" O.C. FOR I P~YWOOD DKIP EDGE , gn NAILS ,. 6" O.C. CONTINUOUS 2 X 4 SPRUCE OR BETTER GABLE FASCIA NAILED TRUSS ATTACH LADDER TO WITH ( 2 ) RO~VS TOP CHORD OF GABLE 8D NAII.S 12" O.C. TRUSS W/( 2 ) 16 D NAILS STAGGERED AT 24" O.C. SHEATHING TO NAILED WITH 8D COMMON NAF[-S ~ 6" O.C. @ EDGES AND 11" O.C. INTERMEDIATE ( TYPICAL ) 12" max. NOTE: ALL NAILq TO BE IS 6 : ~,, ~v,,~, COMMON NAILS MINIMUM · TYPICAL DROP GABLE DETAIL 2 X 4 SPRUCE OR BETTER LOCKING CENTERED BENEATH SHEATHING JOINT. ATTACH BLOCKING 30 LB. FELT OVER 3 ) 161) TOENAILED OR 15/32" MIN. SHEATHI]qG ( 2 ) 16D NA~-S ~2/~ 16D ENDNAILED BOTH EACH LADDER ENDS. 2 X 4 LADDERS #1 PINE NAILS AT OR 2X6 SPRUCE AND 6" O.C. DRIP BETTER 16" O.C. EDGE, AND 4" O.C. FOR ' 8D NAILS @ PLY'WOOD CONTINUOUS 2 X 4 CONNECTOR SPRUCE OR BETTER #360 UPLIFT MIN. FASCIA NAILED CONNECTOR FOR WITH ( 2 ) ROWS ~7,i0 UPLIFT M1/4. 10D NAILS O.C. STAGGERED 24" MAX. I,, SHEATHLNG TO BE NAILED WITH SD CONICION NAILS 6" O.C. @ EDGES 12" O.C. LNTER.,MEDL-~TE ( TYPICAL ) DROP GABLE TRUSS NOTE: ALL NAILS TO BE IS7 COMMON NAII,.q MINIMUM · TYPICAL GABLE END WITH TRUSS TO CONCRETE END WALL ,-- WITH CATHEDRAL CEILING ; X 4 SPRUCE OR BETTER LATERAL ;ENTER WITH (1) 10D ~ /I ~ END TRUSS _,'OMMON NAr[.S, ' · SHEATHING TO BE ~ NAILED WITH 8D COMMON NAILS ! 6" O.C. @ EDGES Ah'D ' 0.C. BRAChNG ALSO ~ 12" O.C. INTER3VfEDIATE ',.EQUIRES CONNECTOR ( TY3PICAL ) a~D ,~'r 400 LBS. V ~' 24" O.C. OUT FROM RIDGE. STUDS MUST GYPSUM WALL REACII FROM BOARD W/BLOCKING P.T. PLATE TO NAILED TO STUDS TOP OF GABLE 16D CONIMON WITH (1) I6D COMMON NAILS @ 16" O.C. NAn. S ~ /TO HOLD GABLE / J !ll~] TOP. T. PLATEAND ; 2X6 STUDS TO GABLE cON~CTo~ ~CW. ~ ~ ~,'~ VE~r~C,~LS RATED AT 400 LBS. EACH STUD /O ~ HURRICANE STRAP 4' O/C / BENT UP AND ,__. OVER GABLE BOTTOM CHORD 2x6 P.T. WrTH U2" · O. "j" BOLTS OR MUD ANCHORS AT 4' O.C. NOTE: OFHONAL CEILING FURRING NOT SHOWN FOR REQUIREMENTS OF TRUSS MANUFACTURER OR T.P.I. 85 · · TYPICAl, GABLE END WITH NO TRUSS TO CONCRETE END WALL ,.. WITH CATHEDRAL CEILING 1 X 4 SPRUCE OR BETTER LATERAL BRACE 8' O.C.WITH I 16I) COMMON NAILS OR 1X4 ~el AT ~" ON CENTER WITH (1) 10D COMMON NAILS. 'x~ SHEATHING TO BE ~, ~ NAILED WITH 8D ~ ~ COMMON NAILS L 6" O.C. @ EDGES AND $' O.C. BRACING ALSO I ~/[ ,A---' 12" O.C. h'NTERMEDIAI'E REQLrlRES CONNECTOR ( TYPICAL ) RATED AT 400 LBS. V ~q 1x8 STLrDS AT 24" O.C. OUT FROM RIDGE. STUDS MUST GYPSUM WALL KEACH FROM BOARD W/BLOCKING P.T. PLATE TO NAILED TO STUDS TOP OF GABLE WrrH (1) 16D COMMON NAILS CONNECTOR KEQD. RATED AT 400 LBS. / EACH STUD / · 2x8 P.T. WTrH I/Z" "J" BOLTS OR MUD ANCHORS AT 4' O.C. NOTE: OPTIONAL CEILING FURRING NOT SHOV~N FOR TYPICAL SIDEWALL SECTION 30 LB. FELT OVER 15/32" NEINIMIIIVI SHEATHING NAII-ED 6" O.C. EDGES AND 12" O.C. FIELD. PLYWOOD MUST EXTEND TO OUTSIDE EDGE OF 6" ON CENTER NArl-hNG FASCIA BOARD BOTH DRIP EDGE AND PLY~VOOD. 3" OVERLAP REQUIRED FOR VALLEYS AND DRIP EDGE. ALL METAL TO BE INSTALLED ~R DRY h'N INSPECTION CONNECTION REQD. FOR VERTICAL AND HORIZONTAL LOADS CONTh~IlOUS 2 X 4 SPRUCE OR BETTER SUB-FASCIa~ 8D NAILS 12" O.C. STAGGERED NOTE: WHEN OVERHANG OR CANTALEVER EXCEEDS PLYWOOD MUST BE N?,j. LED ABOVE AND GLUED ~VITH A.N APPROVED PAaNEL ADHESIVE ... NOTE: ALL NAILS TO BE IS 9 an,, ,.,,,n, COI~IMON NAII.S.MrNIMUM TYPICAL FRA1VIE V~rALL CORNER DETAIL SEE ISII FOR GARAGE DOOR OPENINGS FOUR 10D REQD. ALTERNATE TOP PLATE OVERLAP H~C~ mAP REQD. ALL COI~. M~~ ~IS00 TENSION RANG, REQD. AT BOSOM OF DBL. TOP PLATE ONLY. TWO 10D NAILS REQD. + - 45 EACH STUD DEGREE r'X4 '~~.LETL~GLE BRACE REQD. AT ALL CORNERS AND AT lO' ON CENTER ON ALL WALLS TtIAT ARE NOT SItEATIIED. BRACE TO EXTEND TO BOTTOM OF BOTTOI~I PLATE. ( NOT StlOWN ) IS10 .~,m ,r,~..., COMMON NAILS MINIMUM . . , TYPICAL FRA1VIE GARAGE DOOR & CORNER DETAIL IF DIYFANCE IS LESS THAN 3' HEADER MUST EXTEND lf~X) LB. RATED TO END OF WALL CORNER STRAP RI~QUIXED CONNECt TRUSSES OR 0 PLICES t34 SHF. ATHING FRAMING ABOVE TO N S ALLO~VED IN THIS AREA HEADER, NOT DOUBLE TOP PLATES _ ,__ NO SPLICES ALLOWED IN Ti{ISARP. A _ ,__  PROVIDE CONNECTION 1500 LB RATED FOR REQUIRED UPLIFT STRAP REQUIRED PROVIDE CONNECTION FOR KEQUIR ED UPLIFT DBL. STUD REQUIRED Nows: ~ ~=-~ ~o ~- IS 11 COMMON NAII-S biINIMUM TYPICAL RAFTER FRAiVIING ,RIDGE BEAM TO BE NOT LESS THAN THE DEP'I'H OF THE RAFTER END CUT AND SHALL BE STRUCTURALLY FUNCTIONAL RAFFERS SHALL BE ...,-, PLACED DIRECTLY OPPOSITE EA(ZI-I OTHER H/3 COLLAR TIE TO BE IN UPPER THIRD OF ROOF ..... SYSTEM IX6 MINIMI/M ~ COLLAR TI~ REQD. ALL RAFI'ERS OR CEILLNG JOIST PARALLEL TO RAFTERS x ALL RAFTERS, JOIST, AND RIDGE BEAMS SHALL COMPLY VdTH NFoPA SPAN TABLES FOR JOIST AND RAFTERS. ANCHORAGE IS REQUIRED AT OUTSIDE WALLS AND AT RIDGE FOR LOADS GIVEN ON IS17 AND ISiS IS12 8" X 10" CONCRETE BEAM SPAN ( FEET ) 8' 9' 10' 11' lYj' 1.3' 14' 1.5' A A A B B B B B A B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B (1) ALL TIZES MUST BE FULLY B B ~C~ORED AT TOP (2) CALCULATIONS ARE BASED ON SINGLE SPAN, UN1I=OR2~ILY LOADED BEAM (3) SPAN BASED ON CLOSED. BUILDIMG ENVELOPE (4) CONCRETE SHALL BE A MINIMUM 3000 PSI h'q 28 DAYS (5) REh'NFORCh'NG STEEL SHALL HAVE A MIMIMUM Fy OF 60 KSI · TO P B OTTO M BEAM RF~I~/FORCI~'G RF~I~NFORCI~4G TIF, S B BARS 2 BARS ~3 AT 4" O.C. SEE ISI6 CONCRETE TIE BEAM SCHEDULE: S"xl0" IS 13 12" CONCRETE BEAM SPAN ( FEET ) 9, xo, u, u, m, ,~.4'is,i6, iv; is, m, . C D D D D D ..D D E E C D D D D D 'D E E D D D D D D E E D D D D D D E D D D D D E D D D D D E D D D D E D D D E D D D.D E D D D D E D D D E (l) ALL TIES MUST BE FULLY D D D E ANCHORED AT TOP (2) CALCULATIONS ARE BASED D D D E o~ SINGLE SPAN.UNn:Om~,mY LOADED BEAM D D E (3) sP,,a,~ BASED O~qCLOSED. BUILDING ENVELOPE ..... (4) CONCRETE SHAI BE A D D E ~rrm,4,j~ 3ooo Psx IN =~ DAYS (5) REINI=ORCING STEEL SHALL D D E H.Avn A ~ ~.y OF 60 D E D E D E D E TOP BOTI'OM REINFORCING REINFORCING . T_IF.S _ H,~aNGER-tCHALRS FOR SUPPORT BARS #3 AT S" O.C. SEE IS15 ( 1 ) #5 BARS · ' ( Z ) #6 BARS. #3 AT S" O.C. SEE IS16 · 8" X 16" CONCRETE BEAM SPAN ( FEET ) .... 8' 9' 10' 11' 1.2' 1.3' 14' 1.5' 16' 17; 18' I 1.9' 20' [ F F F F F F F F G G G G G '~ F F F F F F F G G G G G H B F F F F F G G G G G G H H ~ F F F G G G G G G H H H H ~ F F F G G G G G :.G H H H H ~ F F F G G G G G H H H H I ~ F F G G G G G G H H H I I !hFGGGGGGGHHHI ~F GG G' G G G H H H I ~ G G G G G G G H H H I ~ ~. G G G G G G H H H ~ G G G G G G H H H I ~ G G G G G G H H I ~; G G G G G H H H ~g G G G G G H H H I ![~ G G G G G H H I (1) ALL TIES MUST BE FULI I ~ ANCHORED AT TOP ~... G G G G H H H I a) CALCULA'nO~S ARE B,, ON SING LE SPA N, UNIFORaX It4 LOADED BEAM :.,, G G G G H H I o) SPAN BASED ON CLOSE] BUILDING ENVELOPE i~, G G G G H H I (4) CONCRETE SHALL BE A MINh'MUIvl 3000 PSI IN 28 Di :~ G G G G H H I ~5~ ~.,n:ORCnqG S~EL S~ .L /lAVE A MINIMUIvl Fv OF 6C KSI TOP BOTTOM BF. AM REiNFOR~!lWG RF,..U,4FORGiNG TIES G #5 BAILS 2 #5 BARS #3 AT 7" O.C. SEE IS16 tI ( 2 ) #5 BARS ( 2 ) #6 BARS. #3 AT 7" O.C. SEE IS16 I ( 2 ) #5 BARS ( 2 ) It7 BARS #3 AT 7" O.C. SEE IS15 CONCRETE TIE BEAM SCHEDULE: 8"x16" IS ALTERNATE BEAM SIZES KEQIfIRED, SEE REQUIRED, SEE 1., 16" BEAM SCHEDULE. 16" BEAM SCHEDULE. TIES CLOSED AND TIES CLOSED A~\'D · ANCHORED AT TOP. 1' 2" AaNCHORED AT TOP. , 3" . _ 8"X18" TIE,BEANI 8"X20" TIE BEAM CALCULATIONS ARE BASED ON SINGLE SPAN, UNIFORMLY LOADED BEAM. · BEA~ SPANS ARE BASED ON CLOSED BUILDING ENVELOPE CONCRETE SHALL BE A MINIMUM 3000 PSI IN 28 DAYS REINFORCING STEEL SHALL HAVE A MINIMUM Fy OF 60 KSI IS16A TYPICAL TIE SPACING SEE BEA/~ TIE ~PACING SCHEDULE ~4" O.C. , FOR TIES FOR TI~ SPACING Sp~,.BCn~G MAINTAIN 3" ~ #3 TIES BrHERE EDGE DISTANCE REQUIRED, SEE TOP AND BOTTOM SCHEDULE. TIES CLOSED AND AMCHORED AT TOP. CALCULATIONS ARE BASED ON SINGLE SPAN, UNIFORaMLY LOADED BEAM. BEAM SPANS ARE BASED ON CLOSED BUILDING ENVELOPE CONCRETE SHALL BE A MINIMUM 3000 PSI IN 28 DAYS REINFORCING STEEL SHALL HAVE A ,MINIMUM Fy OF 60 KSI IS16 CONTEFTIONAL ROOT FRAEI~G ~LIFT LOAD B~lding Wid~ 20' 24' 28' 32' 36' Ro~ Slope 2/~ ~ O.C. 574 636 698 760 822 ~ O.C. 763 846 928 1011 1093 e O.C. 1148 1272 1396 1520 1644 Roof Slope 3/12 e O,C, 623 677 731 785 839 e O,C, 829 900 972 1044 1116 e O,C, 1246 1354 1462 1570 1678 Roof Sl@pe 4/12 ~" ~ C, 609 663 717 771 825 ;e -C, 810 882 954 !025 1097 ~w O;C. 1218 '1326 1434 1542 1650 Roo.f Slope 5/12 ae O,C, 588 640 692 744 796 ~e 0,C. 782 851 920 990 1059 &e O,C, 1176 1280 1384 1488 1592 Roof Slope 6/12 2" O.C, 560 608 656 704 752 6e O.C. 745 809 872 936 1000 4e O.C. 1120 1216 1312 1408 1504 Roof Slope 7/12 .2" O,C. 406 458 510 562 614 .6" O,C. 540 609 678 747 816 =4e 0.C. 812 916 1020 1124 1228 .. Is-17 e· HORIZONTAL LOAD TE~ RATTER, (LBS} "' 4 IT. OvzL~KA~G ELI. BuildLng ~idth 20' 24' 2~' 3~' 36' Spacing Roof Slupe =]12 ~2" O.C. 12 14 15 17 18 16" O.C. 16 18 20 22 24 24" O.C, 24 28 30 34 ~6 Roof Slope 3/12 12" O.C. 36 40 45 50 54 16" O.C. 48 53 60 67 72 24" O.C. 72 80 90 100 lea Roof Slope 4/12 12" O.C. 60 68 75 ~3 90 16" O.C. 80 90 100 110 120 24" O.C. . 120 136 150 166 Igo Roof Slope 12" O.C. 84 95 105 115 126 16" O.C. 112 126 140 150 168 24" O.C. 168, 190 210 230 Roof slope 6/12 12" o.c. 104 117 130 143 156 16" o.c. 135 156 173 190 207 24" o.c. ,208 234 260 286 Roof Slope 7/12 12" O.C. 136 153 170 187 204 16" O.C. 180 204 226 249 27! 24" O.C. 272 306 340 374 408 .. WALL B E .... :. SIDE LENGTH A -< B+C+D+E+F+G THE SUM TOTAL LENGTHS OF Si:IEAR~'IALLS 1N ANY DIRECTION · SHALL BE EQUAL OR GILEATER THAN T'rLE LENGTH 0FTttE PEILPENDICULAR SIDF-- LF_JqGTJt OF T}FE STRUCTURE CONS IDEP, FAD SEPERATE BUILDINGS YOR DETERI411'FfNG SHY_ARWAI_LS. DRAG STRUTS MAY BE USED AT ADJOINING BUILDING SECTIOHS TO MEET SHEAR- : WALL RE[~UIREMENTS, IF CONhtCTIONS I:0R HORIZONTAL LOADS CAN BE MET. ISi c ALU~iINIr~i W3NDOW INSTALLATION ( MASONRY ONLY ) ~_,6' 4' MAXIMU1VI ROUGH OPENING ~ ~ 1 ' CONC. SCREWS BETWEEN WINDOW 18" ON CENTER AND BUCKING CONC. SCREWS 1~" ON CE~NTER 1X P.T. BUCK,LNG FASTENED WITH 3/I(f" X CONC. SCREWS 18" ON CENTER ~ SHIM 3/8" MAXIMUM BETWEEN ~VINDOW AND BUCK. LNG /~ EXTERIOR DO OR INSTALLATION ( MASONRY ONLY, SOLID CORE WOOD OR METAL CLAD EXTERIOR GRADE ) , 6' 4" MAXIMUM MASONRY OPENING~ I S}~ AT O~ CENTER SINGLE LEA~ 12" ON CE~ER YOR BOYLE LE~ DOOR P~EL · ~L S ~S ~ F~D ~ ~10 X l" FLAT  ~16" X 4" CON~ HEAD ~L  CON~ SCREWS 1~' ON CE~ER FOR I2" ON C~ER FOR O~C. FO~ DOUBLE L~F DOORS ~ ~ ( I ) IN~L }~GE SCRgVS I10 X 2-1/2" ( 2 ) IN~ALL LOCK SET. ( 3 ) IN~ALL SECUR~Y S~IKE SCRBVS ( ~ X 2-U2" ) IN ~RIKE P~T~ ADjU~ ~KE PLATE, ADJUST ~RIKE PLATE FOR SECURE DOOR ~T, TIIEN ~GllEN SCREWS. NOTE: ~8 X 2-UZ" SCREWS MU~ BE SECURELY ANCIIOR~ TIIROUGlt Tile FRA~IE ~OTIIE ~D TO PRO~DE PROPER ~KE P~TE ~R~G~ AND SECUre. . IS21 TRUSS DESIGN FOR OPEN LANAI'S / PORCHES .,. ~ ATTACH TRUSS FOR VERTICAL ~-~ AND HORIZONTAL LOADS. TRUSS MUST BE DESIGN'ED WITH TH3S SECTION EXTERIOR EXPOSED TO ~'B'qD OUTSIDE WALL TO BE B.EAM BUILT AND ( IF ANCHORED '. FOI~ ALL TRUSSES MOST BE ONE OF THE FOLLO~,VING:: GRAVITY AND W]2~D LOADS ( 1 ) BEAEI~G AT EXTERIOR WALL ( 2 ) CANTED OFF EXTERIOR WALL ( 3 ) BUILT TWO PIECE AS Sr~,~tPLE SPANS SHARING EXTERIOR WALL ( 4 ) CARRIED BY GIRDER, USED AS DRAG /~ STRUT OVER EXTERIOR WALL. THE GIEDER MUST EXTEND UP TO THE BOTTOM OF ROOF SHEATHING. ( S ) PANEL POINT PROVIDED TO ATTATCH WALt, FOR ALL VERTICAL AND HORIZONTAL WIND LOADS COLLIER COUNTY CONSTRUCTION CODE ~ITS SUTiPLEKE1TE: CEA;TER 13 SD'aSECTIOH ~302.2.3 Na~al Solid Gro~M or Piles Outside the Flood Zone MONOL~HIC FNDS. OUTSiOF... i'lr2 FLO00 ZOf, l'F OUTs;O-_. eLDG.~_=v' F.F.EL. = CROWN OF RD. , 'reS~ ./t --b./. ~ rr ,...rr"~"""~-.~ · "~1 '1 N~TURAL SOLD GP. OL~.,'D CLEf-,.~ED ----_Y · EXHIBIT A --- mmm I SUPPLEMEMT: CHAPTER 13 · · Natural SOlid GrOund or Piles In th~ 'A' Zone EXHIEJB !~ SUPPLENENT: CHAPTER 13 SUBSECTION 1302.5 AND APPENDIX N One and Tvo famity DveXlinSs Nonolichic rootinS ONE STORY RESIDENCE HASONRY WALL PRA,~IE WALL l) THE HOTTON OF FOUNDATIONS SHALL EXTE|4D NO LESS THAN 12 INCHES BELOW FINISH GRADE. (SBC 1302.1.3) 2) ALL WOOD FRAMING AND SHEATI!IN~ LESS TITAN ~ INCI1ES FRON EXPOSED EARTH SHALL BE PRESSURE TREATED WOOD. (SBC 1703.3.3) 3) CLEARANCE BETWEEN WOOD SIDING AND EARTH SitALL NOT BE LLSS THAN 6 INCHES. (SBC EXHIBIT C (,-'. SUPVLEHENT: CHA~TEK 13 SUBSECTION 1302..S AND APPENDIK N ~ae end Tvo rmmil7 DvetlinZs TWO STORT RESIDENCE !~ASONRY gALL FRA.~!E WALL ~ I~"' ~ ~ - ~r~, ~" O.C. I) THE BOTTOM OF FOUNDATIONS SHALL EXTEND NO LESS THAN 12 INCHES BELOW ~INISH GRADE, (SBC 1302.1.3) 2) 'ALL WOOD FRAMING AND SHEATHING LESS THAN 8 INCHES PROH EXPOSED EARTH SIIALL BE PRESSUKE TREATED ~OOD. 3) CLEARANCE DETgEEN gOOD SIDING AND EARTH SHALL NOT BE LESS THAN 6 INCHES, EXHIBIT D SUPFLEHENT: CHA~TER t3 SUBSECTION 1302.5 AND AP. PENDIX N One and Tvo Family Dvellings Stemvail Footing ONE STORY RESIDENCE EXHIBIT E SUPFLEHENT: CHAFTER |3 SUBSECTION 1302.5 AND AFFENDIX N One &.n.d Tvo Famit3, Dvelli.gs ~WO STORY RESIDENCE FRAHE ',/ALL MASONRY v/ALL , I~ / ~ ~*'' O.C. , '/ , . -/ J ~~ 3 " -- e EXHIBIT F . .~ ' . ., -, *~131s~LLm4~J~Z¢~:~ ~t.;~ 17f S~5~C~iO.~ 1707,7.4 i~ HOTCH~iG .A,NQ IIORED ItOt. E.~ATIONS " FOK L,"T~alO~ WALLS .AHD BEAA~G WALLS . -/d'u-,.ct ~ ,4~ ~r IJr~fe ~ ~,~lZ' feted ~lcs s.~n ncx be I,:cJ ted In ~e u~ serjcn ct E-~ u ~sc.~h s.-x.~_. '~ BORING & NOTCHiNe bF STUDS Becr;n9 Slug { Ncr.-Er, rin,~ 5lu~ ~NOTCHiNG & BORING OF JOI.~TS & RAFTER Mem~e." S;2e ~..cI of t~fc~.~cr Od=: ]/~ cf 5Fc.~ 4f F::~ EXHIBIT G FO~ HO~SA~G WALLS .. t" . ' .~ BORING & HalTCHINe - 2 ~ G . , ~NOTCH]NG & BORING OF JOI~TS & RAFTER ~am~er Size ~ cr Mc~er ~Icr ~ or ~Fc= or Ea: - 2 x 4 T 7/8 . 2 ~ 6 1-318 2 X 8 . ~GtI6 ~3a~ 2-7fie 2 ~ I0 2-5fi6 .-~ . EXHIBIT H STATE OF Fr, ORIDA ) COU)iTY OF COLT.,ZER ) X, DWYOHT E. BROCK, Clerk of Courts in and for the Twentieth Judicial Circuit, Collier County, Florida, do hereby certify that the foregoing is a true copy of: Ordinance No. 95-20. which was adopted by the Board of County Commissioners on the 28th day of March, 1995, during Regular Session. WIT~ESS my hand and the official seal of the Board of County Commissioners of Collier County, Florida, this 3rd day of April, 1995. D~4YGHT E. BROCK ~. '.: .... Clerk of Cour~e and Cler~'~.'~;-.~' ~," Ex-officlo to Board By: /s/Haureen. Kenyon '~ /. ', .,.~: Deputy Clerk ,.?, .'~" :