Loading...
Agenda 03/10/2026 Item #11D (Remove the existing 500-foot separation requirement between facilities with fuel pumps)3/10/2026 Item # 11.D ID# 2026-295 Executive Summary Pursuant to prior Board direction, recommendation to remove the existing 500-foot separation requirement between facilities with fuel pumps, or alternatively, initiate a publicly vetted amendment modifying the site design criteria set forth in Land Development Code (LDC) Section 5.05.05.B.2. OBJECTIVE: For the Board of County Commissioners (Board) to direct staff to delete LDC section 5.05.05 B.2, Facilities with Fuel Pumps, waiver of separation requirements in its entirety, or establish an exemption for the distance separation requirement for facilities with fuel pumps when located within a designated Mixed Use Activity Center, and/or retain the distance separation requirement and include staff’s suggested changes. CONSIDERATIONS: On October 14, 2025, after the Board of Zoning Appeals (BZA) granted PL20240011790, Costco’s request for a waiver from the minimum required separation distance of 500 feet to 132 feet between facilities with fuel pumps and limiting the number of fueling pumps to 12 and six fueling stations, the Board directed staff to evaluate the spatial distance requirement and bring back for discussion. During Costco’s public hearing, the public’s concerns centered on mitigating impacts at the Rattlesnake Hammock/Collier Boulevard Mixed Use Activity Center intersection, the intensity of development at the intersection, pedestrian safety, traffic congestion, offsite stormwater management, and accessibility to major arterial and collector roadways. Processing of similar waiver requests began in 1998, when the Board first adopted the separation-of-distance standard. It had been for a specific ingress/egress situation involving Pine Ridge Road, due to the volume of traffic from several gas stations being developed along Pine Ridge Road and near the I-75 Interchange. Since that time, the County has processed 11 distance-separation waiver requests, with six approved by the BZA, four by the Hearing Examiner, and one withdrawn. Within this 27-year period, the approved waiver distance granted for relief has varied, ranging from 117 feet to 420 feet. It’s notable that the requests had mostly occurred at four-lane and six-lane intersections. Only two out of the 11 petitions occurred on a two- lane collector roadway. As a result of Cosco’s public hearing, the Board decided to re-evaluate the distance separation requirement. Staff is seeking direction from the Board with respect to an LDC amendment to one or more of the following options: A) Eliminate the Waiver of Separation Requirement in its Entirety There is no Florida Statute prohibiting facilities with fuel pumps within 500 feet of each other. Staff conducted a comprehensive review of other Florida Communities’ land development codes and found most communities fail to establish and/or require a design requirement for a distance of separation between fueling facilities and automobile service stations other than the seven communities’ requirements listed below: • Arcadia County: 750’ except at an intersection of any two designated primary state highways, or lots on opposite sides of four-lane streets where there is a median for control of traffic constituting, for all practical purposes, two separate one-way streets and 250’ from places of public assemblage, occupied for a church, hospital, elementary or high school, public library, theater, auditorium stadium arena assembly hall or other similar public or semi-public place where large numbers of people congregate. • Town of Jupiter: 750’ from other fueling station; 125’ on 80’ or smaller collector road ROW, 245’ on 100’ or greater arterial road right-of-way, 400’ from place of worship, hospital, or school. • Palm Beach County: Maximum of two retail gas and fuel sales allowed within 1,000 feet of an intersection and 200 feet from residential unless approved by waiver, separated by either 1,000 or 500 feet between other same, existing, or approved use. • City of Estero: 500 feet separation unless a deviation or variation is granted by Village Council. • City of Lauderhill: 2,000 feet and not applicable when two or more stations are located on different corners of an intersection of two or more streets. • Highlands County: 250’ from lot used for church, playground, playfield, park, hospital, schools, public library, theater, auditorium, stadium, arenas, assembly hall or other similar public or semi-public place where large numbers of people gather. 3/10/2026 Item # 11.D ID# 2026-295 City of Palm Springs: 1) Allowed only adjacent to major arterials and within 250 feet of an intersection of roadway classified as an arterial or collector or adjacent to a signalized intersection, 2) 1,000 feet between the nearest points of property lines on any two parcels occupied or to be occupied for automobile repair, fuel/gas station or convenience store or car wash purpose, and 3) 250 feet from a parcel occupied by church, public or private school, daycare, hospital, governmentally owned or operated building, nursing home or assisted living facility, theater, auditorium, stadium area, place of assembly, and/or public playfield. It should be noted that there are 67 Counties and 411 Municipalities (267 Cities, 123 Towns & 21 Villages) within the State of Florida, which translates to 1.5% of governments with fueling facility separation requirements. Attachment “A” contains the summation of the research materials utilized to evaluate the Board directed request. B) Exempt the separation distance requirement within all designated Mixed Use Activity Centers. This option arises from evidence presented by Cosco’s locational analysis and the economic synergy of multiple fueling facilities located at major activity center intersections which serve large-scale commercial uses while serving existing and future residential development. The 19 mixed use activity centers’ locations identified in the Future Land Use Map are based on major road intersections and spacing criteria. C) Modify the separation requirements and evaluation requirements of LDC section 5.05.05 B and H. This option directs staff to publicly vet and proceed with additional modifications that would improve the standards and site design requirements for facilities with fuel pumps, which may include, but are not limited to the following: 1) Change the existing distance separation requirement from 500’ to 250’, which could have eliminated 50% of the previously granted waiver requests. 2) Cap the number of fueling pumps/stations at major mixed-use activity centers to no more than three within a one- mile radius of a proposed facility, except for intersections at I-75. 3) Limit the number of fueling stations in a shopping center within a specified distance of any intersection and only on major collector or arterial roadways. For fueling stations on a local roadway, require conditional use or variance approval. 4) Require and prioritize a written traffic study analysis to justify interconnectivity, safe and efficient mobility for the public’s benefit, instead of a market study analysis. 5) Limit the number of driveways and access points on roadways unless there is an integrated driveway within a PUD and or Mixed Use Activity Center. 6) Expand the minimum dimensional site design requirements to address : • Depth from all residential land uses; • Distance from school, public playground, hospital, church, etc.; and 3/10/2026 Item # 11.D ID# 2026-295 • Distance from public water supply wells to protect groundwater infiltration. 7) Expand the current list of factors to waive part or all of the separation requirements by including: • Whether an adequate vehicular designed queuing area and buffer and landscaping to residential land uses are proposed. • Whether the total number of trips generated by the number of fuel pumps and its associated land use does not exceed the maximum allowable number of peak hour trips for the roadways’ connection. • Whether there are any onsite or offsite improvements established by a development commitment to mitigate adverse impacts. This item furthers the County's objective to operate an efficient and customer-focused permitting process. FISCAL IMPACT: There are no anticipated fiscal impacts to Collier County, except for the costs associated with processing and advertising the proposed LDC amendment, estimated at $50.00. GROWTH MANAGEMENT IMPACT: There is no growth management impact associated with this action. LEGAL CONSIDERATIONS: This item is approved as to form and legality and requires a majority vote for Board direction. -HFAC RECOMMENDATION(S): To direct staff to amend the Collier County Land Development Code relating to the elimination of the facilities with fuel pumps waiver of separation requirements and bring back the draft ordinance to the Board after vetting the amendment through advisory bodies. PREPARED BY: Mike Bosi, AICP, Zoning Director ATTACHMENTS: 1. Attachment-A-Research-Material Application Name BZA Res./ HEX Decision No. Approved Distance Waiver (FT) Number of Fueling Positions Finding Separation By: Location Restriction Minimize Negative Impacts Market Study 2934 Tamiami Trail-Royal Palm Terrace BZA 98-499 400 Sam's Club 22546 Immokalee Rd. BZA 2000-61 182 Seven-Eleven 12750 Tamiami Tr. East-Capri Commercial Ctr.BZA 2000-277 300 Race Trac at Palm Street HEX Report No. 2016-01 Finding and Analysis a. Reduce the number of fueling positions to a maximum of twelve (12). b. Require intersection improvements to Palm Street and US 41 to include dual left lanes, a dedicated through lane and a dedicated right lane.c. Include mitigation standards required by Ordinance 2015-46 for facilities with fuel pumps within 250 feet of residential. d. Enhance the wall requirement of Ordinance 2015-46 with a twelve (12) foot masonry wall with same architectural features as the primary building, on a minimum three (3) foot berm. Landscaping on both sides of the wall as required by Ordinance 2015-46 with tree height of fourteen 14) feet at planting measured from the bottom of the wall. e. No vehicular traffic behind the building adjacent to residential. f. The dumpster and loading area will be no closer to the southern property line than the building. g. Building setback to residential a minimum of 107 feet and parking setback a minimum of forty (40) feet. h. No customer entrances on the south side of the building. i. Light fixtures will meet the International Dark-Sky Association’ s standard for outdoor lighting and including parking lot lighting to be no higher than fifteen (15) feet. j. Outdoor amplified sound is limited to the pump area unless required for safety reasons. Non-safety amplified sound only audible at the fueling position and only allowed from 7 AM to 7 PM. k. Access to Frederick Street is prohibited. l. Provide thirty (30) foot additional right-of-way along eastern property boundary with Palm Street. Race Trac at Palm Street WAWA Naples South Plaza WAWA at Southwest Intersection of Rattlesnake Hammock Rd. and U.S. 41 Tamiami Tr. E. HEX 2017-19 WAWA 191.77 from Seven- Eleven Convenience Store 6 positions for 12 pumps.4-lane Roadway No servicing of automobiles Increase buffer with masonary wall adjacent to residential. Activities center is oriented toward U.S.41 frontage and minimizes impact to adjacent residential. The proposed Wawa improvement will not have any adverse impacts on adjacent land uses. The site development plan for the Wawa includes enhanced landscape buffering and improved vehicular access throughout Naples South Plaza. Conditions in the center will be greatly improved over those that currently exist, in particular in the area abutting residential land uses. The installation of an 8' masonry wall, 3' berm, and enhanced buffering along the residential property line will greatly improve the aesthetics over what currently exists. Additionally, the owners association of the adjacent property has provided their support for the proposed Wawa development. Justified for additional fuel facilities within 5-minute drive time. RaceTrac at Shadowlawn Dr. and US 41. Northeast Intersection HEX 2018-03 185 from existing Kangaroo facility with fuel pumps. 8 positions for 16 pumps 6-lane Arterial 5 minute drive time. Analysis indicated shortage of supply by 2,500,000 gallons annually. With RaceTrac shortage supply will remain. Seven-Eleven at Northeast Corner of Rattlesnake Hammock and Collier Blvd. HEX 2021-13 171 from existing RaceTrac 8 positions for 16 pumps Man-Made Canal and Multi-Lane Intersection Located in outparcel within a shopping center .Access from internal roadway network, connecting to CR 951 by existing bridge north of Hammock Park MPUD boundary, within Good Turn CPUD. No automobile service or repair Abutting property undeveloped. Buffers, lighting, architecture, and setbacks of site design will meet or exceed enhanced code requirements to abate potential adverse impact to residential use. Satisfied all matters in accordance with LDC section 2.6.28.4 Fueling area and heavier traffic areas will be located as far as possible from existing residential properties. Lighting full cutoff with flat lenses, not to exceed 0.5 foot candles at residential PL. Canopies and pumps separated from residential by convenience store and enhanced landscaping. Vaccum and air stations must be located along U.S. 41 frontage. Criteria in LDC section 5.05.05 B.2 has been met. Withdrawn Immokalee Seven-Eleven CPUD at Northwest Corner of Main St. (SR 29) and North 9th St. See Ord. 2021- 22. BZA 2021-116 420 from Handy Convenience Store with 4 fueling stations 16 unleaded and 4 diesel positions. max. 20 fueling positions. 2-lane collector with turn lane onto SR 29 (100 FT. ROW -Main street) N. 9th street- 60' ROW Located on two platted roadways. Estates Shopping Center CPUD- at Northwest Corner of Wilson Blvd. and Golden Gate Blvd. See Ord. 2021-40. BZA 2021-227 370 from Mobile/7-11 fueling station 4 stations and 8 pumps Costco- Southeast Corner of Rattlesnake Hammock Rd. and Collier Blvd. MPUD BZA 2025-216 132 from Seven Eleven fueling station at Northeast Corner of Rattlesnake Hammock Rd. 6 stations and 12 fuel pumps. Any additional, upto 12 pumps must come back to the Board. Two entrances off of 4- lane Rattlesnake Hammock Rd. 581' from RaceTrac at Southwest Corner of RHR and CB. 10 minute drive time.The key finding is that the projected demand increase of 29.09% is greater than the project's 25.95% share of projected supply. This leaves a 3.14% demand surplus, which demonstrates a clear and justifiable need for the project. 5 minute drive time. Project addresses the demand within the market area and need for more supply. Buffers, lighting, architecture, and setbacks will meet the enhanced code requirements for facilities with fuel pumps according to LDC Section 5.05.05.items. No automobile servicing or repair. Access to the building from N. 9th Street is 40 feet from the northern boundary with parking against the building for the rear entrance. The building is a minimum of 100 feet from the residential property and the canopy is on along W. Main Street between the building and the residential property reducing all adverse impacts. Allow parking to be located in front of building facing W.Main Street. 30 FT. residential buffer with 8' ft. wall. Full cutoff fixtures with BUG rating where U=0 , at 15' mounting height at 50 FT from residential properties. BZA Resolution No. HEX Decision No. Fuel Facility- Location Distance Separation Relief in FT. (Remaining Distance) 1998-499 At U.S.41 and Royal Palm Terrace 400 (100) 2000-61 Sam's Club and ? at Immokalee and Airport Rd.182 (318) 2000-277 7-Eleven and Capri Commerce Center 300 (200) 2016-01 7-Eleven and RaceTrac at U.S.41 between Fredrick and Palm Streets.Varies 2017-19 7-E;even and Naples South Plaza at U.S.41 and Rattlesnake Hammock Rd. 191.77 (308.23) 2018-03 RaceTrac and an Existing Facility at Shadowlawn Dr. and U.S. 41. 185 (315) 2021-13 New ASS with convenience store and car wash and RaceTrac at NE corner of Collier Blvd. and Rattlesnake Rd. 117 (363) 2021-116 7-Eleven and Handy Convenience Store at North 9th St. and Mainstreet-Immokalee 420 (80) 2021-227 7-Eleven and Estates Shopping Center Golden Gate Blvd. and Wilson Blvd.370 (130) 2025-216 7-Eleven and Costco at Rattlesnake Hammock Rd. and Collier Blvd.132 (368) ASW- BZA Resolutions and HEX Decisions Distance Separation Table Community Fuel Facilities Separation Distance (feet) Collier 500 Arcadia 750; except at the intersection of any two designated primary state highways, or lots on opposite sides of four-lane streets where there is a median for control of traffic constituting, for all practical purposes, two separate one-way streets. 250; from places of public assemblage, occupied for a church, hospital, elementary or high school, public library, theater, auditorium stadium arena assembly hall or other similar public or semipublic place where large numbers of people congregate. Highlands 250; from any lot used or to be used for church, playground, playfield, park, hospital, elementary or high school, public library, theater, auditorium, stadium, arena, assembly hall or other similar public or semi-public place where large numbers of people congregate schools. Palm Beach Intersection Criteria : applicable uses shall be limited within 1,000 of any intersection, measured from intersection centerlines of each street to nearest exterior wall or outdoor dinning area and a maximun of two at an intersection. Separation Criteria : A use shall meet the following separation criteria of any other same and existing or approved use, measured by straight line between nearest point of exterior wall or outdoor dining area of proposed use: 1,000. Wakulla 150 from residential property, school, public playground, churches, hospital, public library, or institution for children or dependents. Estero 500 Jupiter 400; from place of worship, hospital, or school. 750’ from other fueling station. Separation between street driveway or intersection: 125’ (center line to center line) on 80’ or smaller collector road ROW or 245’ on 100’ or greater arterial road ROW. Lauderhill 2,000; does not apply if 2 or more stations are located on different corners of an intersection of 2 or more streets. Use is prohibited in the General Commercial zoning district if the land use is located on property that abuts property zoned RS-4, RS-5, RM-5, RM-8, RM-10, RM- 18, and RM-22 zoning districts or that abuts a water body zoned PO district and if the land use is located on property with a depth equal to or less than three hundred fifty (350) feet. This land use also is prohibited in the General Commercial zoning district if the land use is located on property where the front or rear property lines are three hundred fifty (350) feet or less from property zoned RS-4, RS-5, RM-5, RM- 8, RM-10, RM-18, or RM-22 districts. Margate 1,000 and 100 from residential Palm Springs 250 from intersection-arterial or collector and a parcel occupied by a church, public or private school, daycare, hospital, governmentally owned or operated building, nursing home or assisted living facility, theater, auditorium, stadium area, place of assembly, and/or a public play field or 1,000 in village. Grass Valley, CA 500 Byron, GA 1,000 Hampton, GA 1-mile Stockbridge, GA 800 Broomfield, CO 1,000 Wheat Ridge, CO 1,000 Dearborn Heights, Mich. 500 Other States County City Other Florida Communities