Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Case No. CESD20240001061
6569037 OR 6378 PG 3170 RECORDED 7/10/2024 11:03 AM PAGES 5 OF THE CIRCUIT COURT AND COMPTROLLER, COLLIER COUNTY FLORIDA 44.00 CODE ENFORCEMENT - SPECIAL MAGISTRATE COLLIER COUNTY, FLORIDA BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA, Petitioner, [/ Case No. CESD20240001058 CESD20240001061/ 'L---eELU20240001051 eEPM20240001063 `---C--FSTVR20240000530 V5. BUOYANCY LLC Respondent. THIS CAUSE came before the Spe�i��:I _ag�strate for public hearing on June 7, 2024, and the Special Magistrate, having received evidenc1. "*h, .L-11 atd argument respective to all appropriate matters, hereupon issues his Findings of Fact, Conclus q; s,of_- `V and Order of the Special Magistrate, as follows: tE FINDINGS OF FACT an.>`_._- . \ `; SIONS OF LAW 1. Respondent, BUOYANCY LLC is the ownerperty located at 2225 23rd St SW, Naples, FL 34117, Folio 45960240004 (Subjecl;raer. 2. Respondent, Kristen Jasinski, the authorized reprcii ritat' Je of the Respondent, was duly notified of the date of hearing by certified mail and posting and -was present at the hearing with attorney Joseph Gugino. Evidentiary Matters 3. The Respondent objected to the evidence to be presented in the sd4a§, d upon the access ranted to the Subject Property b an occupant of the Subject Pr g j p rtY Y P j _ 4. An extensive hearing was held with testimony by Ms. Kristen Jasinski'tlt tutborized representative of the Respondent, Code Enforcement personnel, docu entary and pictorial evidence by both parties, and argument and authorities presented by counsel for the Petitioner and the Respondent. S. The evidence and testimony supported the conclusion that Ms. Lauren Haines, the complainant in these cases, was a legal occupant of the Subject Property on January 26, 2024, when the inspection occurred. 6. Op. Att'y Gen. Fla. 2002-27 cited by the Respondent provides in relevant part that "...a municipal code inspector is without authority to enter onto any private, commercial, or OR 6378 PG 3171 residential property to assure compliance with or to enforce the various technical codes of the county or to conduct any administrative inspections or searches without the, consent of the owner or the operator or occupant of such premises,..." (Emphasis added by Special Magistrate). 7. As it_was: ctermined that Ms. Haines was a legal "occupant" ofhe Subject Property, the AttpG eral Opinion and other authorities cited support the conclusion that evidence obtait a °om,oe inspection conducted by the Collier County Code Enforcement Officer Charles 1V i ," was legally obtained and may, subject to other objections or exclusions raised by Iithg ty and sustained by the Special Magistrate, be admitted as evidence in these cases. Case No. CESD20240_.001058 8. The Petitioner presented substantial competent evidence in the form of testimony and pictorial evidence th proved.{y a preponderance of the evidence that the real property of -the Respondent is in v1olat1O`VdrtSe Collier County Land Development Code 04-41, as amended, Sections 10.02.06(13)(I)( 0A 196(B)(1)(e) and 10.02.06(B)(1)(e)(i) to wit an improved estates zoned property wit&-.t e isive changes to the primary structure including but not limited to the following: interior.ovations, deletion of walls, addition of walls, electrical modifications, plumbing modi#catiotts.kaddition of multiple HVAC units, deletion of wet bar/kitchen and steam rooms, �i�itl t . er permits. 9. The violation had not been abated as'ofate of the public hearing. Respondent presented testimony that no one is currently oc'cGpyk ;; premises. Case No. CESD20240001061 , 10. The Petitioner presented substantial competet�fe ;( in the form of testimony and pictorial evidence that proved by a prepondera t `e:-evidence that the real property of the Respondent is in violation of the Collier County a elopment Code 04-4I, as amended, Sections 10.02.06(B)(1)(a), 10.02.06(B)(1)(e) and'6(B)(1)(e)(i) to wit an improved Estates zoned property with a pump house in the rear erected-iyithout permits and including electrical and plumbing modifications. `; 11. The violation had not been abated as of the date of the Case No. CELU20240001051 12. The Petitioner presented substantial competent evidence in the form otes�imony and pictorial evidence that proved by a preponderance of the evidence that 16je eaa property of the Respondent is in violation of the Collier County Land Development 66de 04-41, as amended, Sections 1.04.01(A) and 2.02.03 to wit an improved Estates zoned property conducting event hosting activities which is not permissible on this site. Respondent presented testimony that unpermitted events are not taking•place. Case No. CEPM20240001063 13. The Petitioner presented substantial competent evidence in the form of testimony and pictorial evidence that proved by a preponderance of the evidence that the real property of the Respondent is in violation of the Collier County Land Development Code 04-41, as amended, OR 6378 PG 3173 Case No. CESD20240001061 A. Respondent is found guilty of violation of Collier County Land Development Code 04-41, as amended, Sections 10.02.06(B)(1)(a), 10.02.06(B)(1)(e) and 10.02.06(B)(1)(e)(i) to wit an improved Estates zoned property with a pump house in the rear erected without permits and including.e 64rical and plumbing modifications. B. Respondent;'. 'ordered to pay operational costs in the amount of $111.70 incurred in the prosecution;i�is ease within thirty (30) calendar days from the date of this hearing (July 7, 2024). C. Respondent musfiate the violation by obtaining all required Collier County Building Permit(s) or Demolition Permit -Ant— ions, and Certificate of Completion/Occupancy for the unpermitted pump house and the a p,er dittted modification to the related plumbing within 120 days of this hearing (October 5, 2024 or a:-fmc of $200 per day will be imposed until the violation is abated. Case No. CELU20240001 A. This matter is Dismissed. . Case No. CEPM20240001063i` `. A. This matter is Continued for 56 days to time Respondent will present a report c Case No. CESTVR20240000530 A. This matter is Continued to the July 12, 2024, Respondent and Petitioner will each present a short-term rentals in Estates zoned properties. All Cases 2, 2024, Special Magistrate hearing at which iat no health and safety violations are present. hearing prior to which time ng the legality and regulation of A. Respondent shall notify the Code Enforcement Investigator wto, . 4 faQurs of abatement or compliance in order for the County to conduct a final inspection t 1,41-i m abatement. B. If Respondent fails to abate the violation and comply with this Ord eefo ier County Code Enforcement Department may abate the violation using any appropriate ti. to bring the violation into compliance. If necessary, the County may request the servicesol he Collier County Sheriff's Office in order to access the property for abatement and enforce:tltrpfaivisions of this Order. All costs of abatement shall be assessed against the property owner and may become a lien on the property. *** OR 6378 PG 3174 *** DONE AND ORDERED this 7th day of June, 2024, at Naples, Collier County, Florida. .. "' ... � COLLIER COUNTY ODE ENFORCEMENT I, Crystal tC'IGntel, -•Qt wrtsin"firCdlierCouny SPECIALMA ATE do hearb�' ffA th C,8 Jnstroment is a bw and carted cr py of 0orktaElf. ASI=z J/ Date a ickfi. Neale, Esq. Executed b Special Magistrate Patrick H. Neale on 2024. Filed with the S etary to the Speci I Magistrate on 2024 by PAYMENT OF FINES: Any fines; �} ` c to be paid pursuant to this order may be paid at the Collier County Code Enforcement Division :�S 64orth Horseshoe Drive, Naples, FL 34104, phone # (239) 252- 2440 or w,,kw.colliercountyfl.go%•. A -le se f lien or confirmation of compliance or confirmation of the satisfaction of the obligations of this u�fecay also be obtained at this location. APPEAL: Any aggrieved party may appeal within thirty (30) days of the execution of the C but shall be limited to appellate review of the ri responsibility of the appealing party to obtain a Courts. Filing a Notice of Appeal will not auto of the Special Magistrate to the Circuit Court aled. An appeal shall not be a hearing de novo ted within the original hearing. It is the ;cecord of the hearing from the Clerk of sj�the Special Magistrate's Order. I HEREBY CERTIFY that a true and correct;, ebpj�°vii this MAGISTRATE, has been sent by U.S. Mail o this ` ii af� BUOYANCY LLC, 2805 HORSESHOE DR S. UNIT 10, NA 341 Code OF THE SPECIAL 2024 to Respondent, 6569037 OR 6378 PG 3170 RECORDED 7/10/2024 11:03 AM PAGES 5 OF THE CIRCUIT COURT AND COMPTROLLER, COLLIER COUNTY FLORIDA 44.00 CODE ENFORCEMENT - SPECIAL MAGISTRATE COLLIER COUNTY, FLORIDA BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA, Petitioner, �� Case No. CESD20240001058 CESD20240001061/ ----e'E LU2 0240001051 CEPM20240001063 ---C-ESTVR20240000530 V5. BUOYANCY LLC Respondent. THIS CAUSE came before the S Special Magistrate, having received evidi hereupon issues his Findings of Fact, Col follows: F 1. Respondent, BUOYANCY LLC is the Naples, FL 34117, Folio 45960240004 ite for public hearing on June 7, 2024, and the argument respective to all appropriate matters, W and Order of the Special Magistrate, as located at 2225 23rd St SW, 2. Respondent, Kristen Jasinski, the authorized representat` a of the Respondent, was duly notified of the date of hearing by certified mail and posting and -was present at the hearing with attorney Joseph Gugino. Evidentiary Matters 3. The Respondent objected to the evidence to be presented in the ses: a, d upon the access granted to the Subject Property by an occupant of the Subject Pro m ",� 4. An extensive hearing was held with testimony by Ms. Kristen Jasinski ` hey i-r�fhorized representative of the Respondent, Code Enforcement personnel, documentary and pictorial evidence by both parties, and argument and authorities presented by counsel for the Petitioner and the Respondent. S. The evidence and testimony supported the conclusion that Ms. Lauren Haines, the complainant in these cases, was a legal occupant of the Subject Property on January 26, 2024, when the inspection occurred. 6. Op. Att'y Gen. Fla. 2002-27 cited by the Respondent provides in relevant part that "...a municipal code inspector is without authority to enter onto any private, commercial, or OR 6378 PG 3171 residential property to assure compliance with or to enforce the various technical codes of the county or to conduct any administrative inspections or searches without the, consent of the owner or the operator or occupant of such premises,..." (Emphasis added by Special Magistrate). 7. As it..- etermined that Ms. Haines was a legal "occupant" of the Subject Property, the Attop�G eral Opinion and other authorities cited support the conclusion that evidence obtaiteI m.{he inspection conducted by the Collier County Code Enforcement Officer Charles i °inio' was legally obtained and may, subject to other objections or exclusions raised b� the ' y and sustained by the Special Magistrate, be admitted as evidence in these cases. Case No. 8. The Petitioner prese09d substantial competent evidence in the form of testimony and pictorial evidence thdproved.�y a preponderance of the evidence that the real property of -the Respondent is in violatio , t ft Collier County Land Development Code 04-41, as amended, Sections 10.02.06(B)(1}(a), 0;(}206(B)(1)(e) and 10.02.06(B)(1)(e)(i) to wit an improved estates zoned property wil -'te tslv�e changes to the primary structure including but not limited to the following: inferioF.ovations, deletion of walls, addition of walls, electrical modifications, plumbing mod(catiahs addition of multiple HVAC units, deletion of wet bar/kitchen and steam rooms, wstfft,per permits. 9. The violation had not been abated ' ,44te of the public hearing. Respondent presented testimony that no one is currently oc— pytr e premises. Case No. CESD20240001061 10. The Petitioner presented substantial compete'e�r;�t>Tn� in the form of testimony and pictorial evidence that proved by a preponderaoPtfte`evidence that the real property of the Respondent is in violation of the Collier County`sdflbegelopment Code 04-4I, as amended, Sections 10.02.06(B)(1)(a), 10.02.06(B)(1)(e) and` kO~0%06(13)(1)(e)(i) to wit an improved Estates zoned property with a pump house in the rearerected- without permits and including electrical and plumbing modifications. 11. The violation had not been abated as of the date of the Case No. CELU20240001051, "k K 12. The Petitioner presented substantial competent evidence in the form o t¢s mony and pictorial evidence that proved by a preponderance of the evidence thattesl property of the Respondent is in violation of the Collier County Land Development Glide 04-41, as amended, Sections 1.04.01(A) and 2.02.03 to wit an improved Estates zoned property conducting event hosting activities which is not permissible on this site. Respondent presented testimony that unpermitted events are not taking'place. Case No. CEPM20240001063 13. The Petitioner presented substantial competent evidence in the form of testimony and pictorial evidence that proved by a preponderance of the evidence that the real property of the Respondent is in violation of the Collier County Land Development Code 04-41, as amended, OR 6378 PG 3173 Case No. CESD20240001061 A. Respondent is found guilty of violation of Collier County Land Development Code 04-41, as amended, Sections 10.02.06(B)(1)(a), 10.02.06(B)(1)(e) and 10.02.06(B)(1)(exi) to wit an improved Estates zoned property with a pump house in the rear erected without permits and including,:el*rical and plumbing modifications. B. Respondent;' 'oFdgTed to pay operational costs in the amount of $111.70 incurred in the prosecution o is se within thirty (30) calendar days from the date of this hearing (July 7, 2024). C. Respondent must date the violation by obtaining all required Collier County Building Permit(s) . or Demolition Permit,-in:5"jec ions, and Certificate of Completion/Occupancy for the unpermitted pump house and the anpetted modification to the related plumbing within 120 days of this hearing (October 5, 2024 or a:fin"f $200 per day will be imposed until the violation is abated. Case No. CELU202 A. This matter is Dismissed. Case No. CEPM20240001063 A. This matter is Continued for 56 days to time Respondent will present a report c Case No. CESTVR20240000530 A. This matter is Continued to the July 12, 2024, Respondent and Petitioner will each present a short -tern rentals in Estates zoned properties. All Cases 2, 2024, Special Magistrate hearing at which iat no health and safety violations are present. hearing prior to which time ng the legality and regulation of A. Respondent shall notify the Code Enforcement Investigator wit.-T4•hqurs of abatement or compliance in order for the County to conduct a final inspection to, t ii�m abatement. B. If Respondent fails to abate the violation and comply with this Ordeeo)ier County Code Enforcement Department may abate the violation using any appropriiiee m 0 . to bring the violation into compliance. If necessary, the County may request the services:ol�he Collier County Sheriff's Office in order to access the property for abatement and enforce:thrpTbvisions of this Order. All costs of abatement shall be assessed against the property owner and may become a lien on the property. *** OR 6378 PG 3174 *** DONE AND ORDERED this 7th day of June, 2024, at Naples, Collier County, Florida. I,CrystatK`IGntel, -.�i• wsrniM r,rcoiuerCounty COLLIER COUNTY ODE ENFORCEMENT do bwrc fpAl f as instronient is a true end coned SPECIAL MA ATE copy of jhe a i upty�tWN Bar. e�� ,•� ; ^� peputyG c,� , • :,.:. •.••���� _ a Ick . Neale, Esq. �`i Lr f j;0``� • <, Executed b Special Magistrate Patrick H. Neale on 2 02 4. Filed with the S etary to the Sp e i ! Magistrate on 2L3 2024 by PAYMENT OF FINES: Any fines,:or, to be paid pursuant to this order may be paid at the Collier County Code Enforcement Division , 8.O�*orth Horseshoe Drive, Naples, FL 34104, phone # (239) 252- 2440 or mm.colliercountyfl.gov. An _ . A' - eme' f lien or confirmation of compliance or confirmation of the satisfaction of the obligations of this'.artein ay also be obtained at this location. APPEAL: Any aggrieved parry may appea( within thirty (30) days of the execution of the but shall be limited to appellate review of the ri responsibility of the appealing party to obtain a Courts. Filing a Notice of Appeal will not auto I HEREBY CERTIFY that a true and MAGISTRATE, has been sent by U.S. Mail of BUOYANCY LLC, 2805 HORSESHOE DR S. Ua of the Special Magistrate to the Circuit Court aled. An appeal shall not be a hearing de novo led within the original hearing. It is the •tecord of the hearing from the Clerk of s�jh;the Special Magistrate's Order. :onect, eEipCr�this RDER OF THE SPECIAL this d ,`' f 2024 to Respondent, T 10, NA 3410 . Code INSTR 6720483 OR 6500 PG 1144 RECORDED 8/20/2025 11:12 AM PAGES 3 CRYSTAL K. r,.INZEL, CLERK OF THE CIRCUIT COURT AND COMPTROLLER, COLLIER COUNTY FLORIDA REC $27.00 CODE ENFORCEMENT - SPECIAL MAGISTRATE COLLIER COUNTY FLORIDA BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA, Petitioner, vs. Case No. CESD20240001061 BUOYANCY LLC l Respondent. j THIS CAUSE came before t1l pie` ial Magistrate for public hearing upon the Petitioner's Motion for Imposition of Fines/Liens txt Adga§t 1, 2025, and the Special Magistrate, having heard argument respective to all appropriate m ( ►' Jlcrcupon issues his Findings of Fact, Conclusions of Law and Order of the Special Magistrate, as fo6�,;k'� FINDINGS OF F)VeT CONCLUSIONS OF LAW 1. Respondent, ` p BUOYANCY LLC is the owpel of the property located at 2225 23rd St SW, Naples, FL 34117, Folio 45960240004 ,'" { 2. On June 7, 2024 owner was found guilty of Co r 0punty Land Development Code 04-41, as amended, Sections 10.02.06(B)(1)(a), 10. 9(e) and 10.02.06(B)(1)(e)(i), to wit an improved Estates zoned property with a pur Int t),le rear erected without permits and including electrical and plumbing modifications.` 3. An initial Order was entered by the Special Magistrate o�rderingzRespondent to abate the violation on or before October 5, 2024 (Order) or a fine ofC,,� 0 per day would be assessed for any violation that continues thereafter until abatcmei —C Wrmed. The Order is recorded at Collier County Records, OR 6378 PG 3170. . 1 4. The violation has not been abated as of the date of the public h g ' 5. Previously assessed operational costs of S111.70 have been paid. 6. Respondent was duly noticed for the public hearing regarding the Cot ty otion and Kristen Jasinski was present at the public hearing. Respondent presented testimony that a determination has been made to demolish the existing pump house and relocate it on the property. Issues with permitting the existing location included a violation of setback requirements. The work is anticipated to be completed within 90 days. This provided sufficient evidence to justify a Continuance of this hearing. OR ,6500 PG 1145 7. No Request for Re -hearing or Appeal pursuant to Ordinance 2007-44, as amended, has been filed. ORDER Based upon the foregoing Findings of Fact and Conclusions of Law, and pursuant to the authority granted in Chapter 1.62, Florida Statutes, and Collier Countv Ordinance No. 07-44, as amended, IT IS HEREBY,,0IIiD iED: A. firtlis 6 anted a Continuance for ninety-nine (99) calendar days (November 7, 2025) of this matter Q. Fines do note 11,4 to accrue. c1 4 C. Respondent is orticrid' o pay operational costs for today's hearing in the amount of SI11.90 within 30 ca ndar days of this hearing (August 31, 2025). D. If Respondent fails to aba cIt y"ation bring the violation into compy Collier County Sheriff's Office provisions of this Order. All c and may become a lien on the and comply with this Order, the Collier County DONE AND ORDERED this 1st day of August 2,0 , .n ,_Naples, Collier County, Florida. COLLIER Od'N. ..CODE ENFORCEMENT SPECIAL MA,C,& TE ,' -%�•� � � atr ck II. NesilE, Esq. /� Executed by: � ' iSpecial Magistrate Patricl. H. al , 2025. Filed with the Secretary to the Special Magistrate on /7�' !7 y 4 lrtN 4f�•" Alt= PAYMENT OF FINES: Any fines ordered to be paid pursuant to this ord tty�be'. aid at the Collier County Code Enforcement Division, 2800 North Horseshoe Drive, Naples, FLF34-0 hone # (239) 252- 2440 or %%%%\N cnlheranmtvtl ee,\ . Any release of lien or confirmation of compliance confirmation of the satisfaction of the obligations of this order may also be obtained at this location APPEAL: Any aggrieved party may appeal a final order of the Special Magistrate to the Circuit Court within thirty (30) days of the execution of the Order appealed. An appeal shall not be a hearing de novo but shall be limited to appellate review of the record created within the original hearing. It is the responsibility of the appealing party to obtain a transcribed record of the hearing from the Clerk of :jr ,purts. Filing a Notice of Appeal will not automatically stay the Special Magistrate's Order. I, Crystal k Khfrd. ol�ourfs in and for cocker county �, do oerttty that�o above Ins"ent is a We and correct �� he odglaat I ier County, Florida er Deputy Clerk Datg a �.,; .,� *** OR 6500 PG 1146 *** CERTIFICATE OF SERVICE I HEREBY CERTIFY that a true and correct copy of this ORDER OF MAGISTRATE, has been sent by U.S. Mail on this /9' day of vsf 2025 cl- BUOYANCY LLC, 2805 HORSESHOE DR S. UNIITT110, NAPLES, FL 34104. Code Enforcement Official THE SPECIAL to Respondent, CODE ENFORCEMENT- COLLIER COUNTY, FLORIDA Code Enforcement Board BOARD OF COUNTY COMMISSIONERS, COLLIER COUNTY, FLORIDA, Plaintiff, Vs. Kristen Jasiinski, and BUOYANCY, LLC, Respondent(s) CASE NO. CESD20240001061 NOTICE OF APPEARANCE AND DESIGNATION OF E-MAIL ADDRESSES ON BEHALF OF RESPONDENT(S), KRISTEN JASINSKI, AND BUOYANCY, LLC PLEASE TAKE NOTICE that the undersigned attorneys, Henry Paul Johnson, Esq. and Jeffrey D. Sam, Esq. and the Law Firm of Henry Johnson Law, hereby file this Notice of Appearance and Designation of Email Addresses on behalf of Respondent(s), Kristen Jasinski and Buoyancy, LLC, in the above -captioned Code Enforcement Case. Counsel hereby designates the following e-mail addresses: Primary E-mail: service(a�henryjohnsonlaw.com Secondary E-mail: hiohnson@henaiohnsonlaw.com Secondary E-mail: si am(a�henryjohnsonlaw.com Accordingly, please provide the undersigned with all future notices, motions and other papers filed in this matter to the above designated e-mail addresses. HENRY JOHNSON LAW 6640 Willow Park Drive, Suite A Naples, Florida 34109 Telephone: (239) 591-0133 Facsimile: (239) 591-0787 Primary e-mail: hiohnson(a)henrylohnsonlaw.com Secondary e-mail: isamghenryiohnsonlaw.com /s/ Henry Paul Johnson, Esq. HENRY PAUL JOHNSON, ESQ. Florida Bar No. 372242 /s/ Jeffrey D. Sam, Esq. JEFFREY D. SAM, ESQ. Florida Bar No. 42113 CODE ENFORCEMENT- COLLIER COUNTY, FLORIDA Code Enforcement Board BOARD OF COUNTY COMMISSIONERS, COLLIER COUNTY, FLORIDA, Plaintiff, Vs. BUOYANCY, LLC, Respondent(s) CASE NO. CESD20240001061 RESPONDENTS' MOTION FOR WAIVER OR, IN THE ALTERNATIVE, REDUCTION OF FINES The Respondent, Buoyancy, LLC, by and through its undersigned attorneys, hereby files its Motion For Waiver Or, In the Alternative, Reduction of Fines and relative thereto state the following: 1. Respondent, BUOYANCY, LLC, is the owner of the property located at 2225 23`d St SW, Naples, Florida 34117, Folio 4596024004. 2. On June 7, 2024, owner was found in violation of Collier County Land Development Code 04-41, as amended, Sections 10.02.06(B)(1)(a), 10.02.06(B)(1)(e), and 10.02.06(B)(1)(e)(i), to wit an improved Estates zoned property with a pump house in the rear erected without permits and including electrical and plumbing modifications. 3. An Order was entered by the Special Magistrate on August 1, 2025 which stated the following: "A. Respondent is granted a Continuance for ninety-nine (99) calendar days (November 7, 2025) of this matter. B. Fines do no continue to accrue. C. Respondent is ordered to pay operational costs for today's hearing in the amount of $111.90 within 30 calendar days of this hearing (August 31, 2025). D. If Respondent fails to abate the violation and comply with this Order, the Collier County Code Enforcement Department may abate the violation using any appropriate method to bring the violation into compliance. If necessary, the County may request the services 1 of the Collier County Sheriff's Office in order to access the property for abatement and enforce the provisions of this Order. All costs of abatement shall be assessed against the property owner and may become a lien on the property." (emphasis supplied) 4. Since the entry of the Order of the Special Magistrate the violation, by acknowledgment by Collier County, the subject violations have since been abated. 5. It has always been the goal of the Respondent to comply with applicable Codes and Ordinances for Collier County and has taken good faith and what Respondent contends are aggressive actions to accomplish same. 6. So as to comply with the Order of this Tribunal, the Respondent submits that it has spent or expects to spend substantial costs and expenses incident to compliance. Wherefore, the Respondent respectfully requests that no fines be ordered or, in the alternative, that a nominal fine be imposed given, inter alia, all efforts by the Respondent to aggressively comply with applicable Codes and Ordinances of Collier County and in fact abate the subject violation. DATED this 26t" of December, 2025. 2 HENRY JOHNSON LAW 6640 Willow Park Drive, Suite A Naples, Florida 34109 Telephone: (239) 591-0133 Facsimile: (239) 591-0787 service(& henry johnsonlaw.com hjohnsonAhenryjohnsonlaw.com jsam(a ,henry iohnsonlaw.com /s/ Heng Paul Johnson, Esc. HENRY PAUL JOHNSON, ESQ. Florida Bar No. 372242 JEFFREY D. SAM, ESQ. Florida Bar No. 42113 BUOYANCY, LLC COLLIER COUNTY CODE ENFORCEMENT TIMELINE CODE ENFORCEMENT CASE CESD20240001061 PERMIT PRDM20241042895 & PRAC20241042897 WELL HOUSE Index Date Descriptor of Event l . February 26, Notice of Violation posted on property 2024 2. May 22, 2024 Notice of June 7, 2024 Hearing is posted on property 3. June 7, 2024 Hearing takes place 4. October 14, Notice of Commencement recorded in Official 2024 Record of Collier County, Florida 5. October 25, Notice of Permit #PRAC20241042897 has been 2024 applied 6. October 26, Letter from Client to Richard Vazquez with details on 2024 approval for permit applications to build accessory structure and to demolish old well house and Product Index Sheet was re -uploaded 7. October 29, Initial Incomplete Submittal Notice 2024 8. October 29, Initial Incomplete Submittal Notice 2024 9. October 31, Payment to Collier County of $219.00 for Demolition 2024 Permit 10. October 31, Demolition permit originally issued 2024 #PRDM20241042895 11. November 6, Stormwater Plan Worksheet 2024 12. November 6, Vegetation Removal Affidavit 2024 13. November 6, Letter from Client to Richard Vazquez relating to 2024 submitting truss drawings and request to that the permit issuance be deferred until truss drawings are submitted 14. November 7, Initial Incomplete Submittal Notice with Product 2024 Index Sheet INDEX - PAGE - 001 15. November 12, Collier County Payment Slip $100.00 for: 2024 o Structural -Application Fee o Zoning Review- Application 16. November 12, Receipt of Payment 2024 17. December 13, Collier County Government Outstanding Corrections 2024 Letter 18. December 13, Client's letter in response to the Collier County 2024 Government Outstanding Corrections Letter with FEMA Elevation Certificate and ICC-ES Evaluation Report attached. 19. January 8, 2025 Email from Robert Moore (Collier County) to Client explaining that the permit is under review and plans cannot be uploaded until the permit is issued 20. January 14, 2025 Collier County Customer Payment Slip for $971.25 for: o Site Engineering o Structural - Review Fee o FEMA - Review Fee o BCAI o DBPR Surcharge o Inspection Fee 21. January 3 1, 2025 Email to Cronin Engineering relating to County approving permit application to build new structure and demolish old structure along with electrical issues related for the After -The -Fact Permit 22. February 5, 2025 Verbal communications from Client to Architect, Brian Palkovic, about meeting on 02/05/2025 to get clarity on scope of work for plans 23.1 March 17, 2025 Permit #PRAC20241042897 issued 24. March 17, 2025 Receipt of Payment- $971.25 25. July 2, 2025 Email from Client to Robert Moore (Collier County) relating to looking for clarification on specific concerns on required inspections for the permit and uploading truss plans 26. July 2, 2025 Letter from Client to Robert Moore and Robert Vazquez (Collier County) confirming submittal of truss drawings INDEX - PAGE - 002 27. July 10, 2025 Permit Subcontractor Affirmation- Jasinski Builders, LLC 28. July 10, 2025 Case scheduled for August 1, 2025 hearing date 29. July 17, 2025 Collier County Payment slip for $50.00 for: o Revision 30. July 28, 2025 Email from Client to Joe Bianchi (Collier County) explaining that 810 Exotic Vegetation Removal is done at the end and there are 13 species that are required for removal on the property 31. July 28, 2025 Email from Client to Collier County Representative Dianna Perryman relating to attempting further on - site inspections and surveys 32. July 28, 2025 Email from Client to Robert Moore (Collier County) relating to project is under further delay because surveyor cannot complete a spot survey for 3 week and describing further delays that are not the fault of the Client. 33. July 28, 2025 Email from Robert Moore (Collier County) to Client confirming that 188 and 199 inspections cannot be scheduled until spot surve is completed. 34. July 28, 2025 Email from Client to Joe Bianchi outlining the bottlenecks and struggles to get assistance to resolve questions and lack of response from specific Collier County Representatives 35. July 31, 2025 Signed Spot Survey Waiver 36. August 1, 2025 Special Magistrate hearing takes place in which case is continued until November 7.2025 37. August 3, 2025 Email from Client to Bradley Holmes, Brian Owen, and Jeffrey Letoumeau (Collier County) breaking down beliefs why the case should be dismissed and fines reversed and discussing specific codes and ordinances. 38. August 5, 2025 Email from Client to Ernie Kerskie at Collier County Appraiser's Office relating to research of aerial photos of property and to determine when shed was built 39. August 5, 2025 Email from Ernie W. Kerskie relating to aerial photos of roe and that the shed is not being assessed INDEX - PAGE - 003 through the Collier County Property Appraiser's Office 40. August 6, 2025 Email from Client to Bradley Holmes, Brian Owen, and Jeffrey Letourneau reviewing building records of property and pushing back on "unpermitted structure" as the structure was built in March of 2000 when the Certificate of Occupancy was given and there has been no filed issue incident to same between then and now current state. 41. August 14, 2025 Revised FL Product Approval/Miami-Dade NOAs 42. August 22, 2025 Email from Client to Bradley Holmes, Brian Owen, and Jeffrey Letourneau following up on August 3, 2025 email and confirming through County portal that no action has been taken recently 43. August 26, 2025 Email between Client and Bradley Holmes comparing other structures on properties in vicinity of claimed violation address and consenting to Mr. Holmes entering Buoyancy, LLC's property. 44. September 11, Permit #PRW120250938957 is issued 2025 45. September 16, Initial approval of impact glass 2025 46. September 16, Receipt of Payment $260.00. 2025 47. September 24, Permit #PRWL20250938957 Certificate of 2025 Completion 48. October 6, 2025 Updated Elevation certificate is published 49. October 8, 2025 Collier County Government Incomplete Revision Submittal Notice 50. October 17, Email from Tonya Chancy (Collier County Planning 2025 & Permitting Technician) to Client requesting that Client reached out to Myron Jacobs regarding outstanding inspections 51. October 1, 2025 Various correspondences, meetings, text messages, to October 27, and attempts from Client to County relating why 2025 there are outstanding requests for duplicate inspections of soffit covering (already passed on August 13, 2025)s in progress and impact glass (already passed on September 16, 2025 INDEX - PAGE - 004 52. October 20, Collier County Payment Slip for $50.00 for Revision 2025 53. October 20, Receipt of Payment 2025 54. October 27, Email from Client to Myron Jacobs (Collier County 2025 Chief Building Inspector)- attempting to contact inspections with Collier County with over ten days without response via email and voicemails 55. October 27, Email from Tonya Chancy (Planning & Permitting 2025 Technician) to Client that there are two inspections pending before the permit can be closed out 56. October 30, Email from Client to Bradley Holmes advising that 2025 the original wellhouse has been demolished and finished all requirements under Permit #PRDM20241042895 57. October 31, Demolition Certificate of Completion of Collier 2025 County PRDM20241042895 58. OCTOBER 31, EMAIL FROM BRADLEY HOLMES TO 2025 CLIENT CONFIRMING THAT THE PERMIT HAS BEEN ISSUED AND CASE SHOULD BE RESOLVED AND CLIENT WILL HAVE OPPORTUNITY TO REQUEST WAIVER OF REDUCTION OF THE FINE AMOUNTS. 59. November 5, Collier County Certificate of Completion for 2025 PRAC20241042897 60. November 6, Email from Client to Miranda Paredes relating to 2025 struggle with voicemail of Collier County and getting ahold of the correct person for related issues 61. November 6, Email from Client to Bradley Holmes attaching files 2025 and photos to show to the Magistrate that the case has been resolved 62. December 1, Email from Client to Bradley Holmes and Jeffrey 2025 Letourneau relating to pump house permit that is closed and requesting Special Magistrate to reduce fines 63. December 30, Fee Summary and Documents related to same. 2025 64. CELU20240001051 Violation Letters & Abatement Confirmation from Special Magistrate Order INDEX - PAGE - 005 L 65. CEPM20240001063 Violation Letter and compliant as of July 4, 2024 66. CESTVR20240000530 Violation Letter and compliant as of July 30, 2024 67. CEVR20240001060 Violation Letter and as of March 3, 2024, no violation was found and case was closed INDEX - PAGE - 006 Case Number: CEAU20240001061 Date: February 26, 2024 Investigator: Charles Marinos Phone:2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Registered Agent: KIKU HOLDINGS, LLC 2805 HORSESHOE DR S STE 10 Naples, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00o19'10"W FOR 150.00 FT; N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: Building and Land Alteration Permits. (Permits, Inspections, Certificate of Occupancy Required) Collier County Land Development Code 04-41, as amended, Section 10.02.06(B)(1)(a) The County Manager or his designee shall be responsible for determining whether applications for building or land alteration permits, as required by the Collier County Building code or this Code are in accord with the requirements of this Code, and no building or land alteration permit shall be issued without written approval that plans submitted conform to applicable zoning regulations, and other land development regulations. For purposes of this section a land alteration permit shall mean any written authorization to alter land and for which a building permit may not be required. Examples include but are not limited to clearing and excavation permits, site development plan approvals, agricultural clearing permits, and blasting permits. No building or structure shall be erected, moved, added to, altered, utilized or allowed to exist and/or no land alteration shall be permitted without first obtaining the authorization of the required permit(s), inspections and certificate(s) of occupancy as required by the Collier County Building Code or this Code. Submittal Requirements for Permits. Building or Land Alteration Permits. Improvement of property prohibited prior to issuance of building permit. Collier County Land Development Code 04-41 as amended, Section 10.02.06(B)(1)(e)(i) Must obtain all required inspections and certificate of occupancy/completion within 60 days of permit issuance. Submittal Requirements for Permits. Building or Land Alteration Permits. Improvement of property prohibited prior to issuance of building permit. Collier County Land Development Code 04-41 as amended, Section 10.02.06(B)(1)(e) Improvement of property prohibited prior to issuance of building permit. No site work, removal of protected vegetation, grading, improvement of property or construction of any type may be commenced prior to the issuance of a building permit where the development proposed requires a building permit under this Land development Code or other applicable county regulations. EXHIBIT - 001 - PAGE - 001 Case Number: CEAU20240001061 Date: February 26, 2024 Investigator: Charles Marinos Phone: 2392806960 Violation Status - Initial DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATION(S). Did Witness: An improved estates zoned property with a pump house in the rear erected without permits and including electrical and plumbing modifications. ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Must obtain all required Collier County Building Permit(s) or Demolition permit(s) and request all inspections through Certificate of Completion/Occupancy for described structure/ alteration. 2. Must be in compliance with all Collier County Codes and Ordinances. Apply for and obtain all permits required for described structure/improvements: OR remove said structure/improvements, including materials from property and restore to a permitted state AND / OR Must cease all improvement activities until such time that any and all required permits are obtained from Community Development and Environmental Services. ON OR BEFORE: 03/27/2024 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $500 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. SERVED BY: ,?" X tul d Investigator Signature Charles Marinos Case Number: CESD20240001061 INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Phone: 239 252-2440 FAX: 239 252-2343 Signature and Title of Recipient Printed Name of Recipient Date 'This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 001 - PAGE - 002 Code Case Details Execution Date 12/8/2025 4:08:33 PM Desc Assigned Required Completed Outcome Comments Not Applicable BrianOwen 3/25/2024 10/9/2025 Not Required Re -Inspection Charles.Marin 3/28/2024 3/29/2024 Non- In the course of contact with Mr. Joseph A. os Compliant Gugino (Joseph.Gugino@daviesduke.com, 239.405.8033), attorney for the respondent, he has requested some additional time to form a cohesive and effective plan to abate the violations on site. Mr Gugino has made regular and clear contact while beginning the process of acquiring the permits required, I agreed accommodate this request and thanked Mr Gugino for his continued efforts. No new permits at this time, will continue to monitor for permit application and issuance. Standing by. MarinosCharles 03/29/2024 11:31 AM Re -Inspection Charles.Marin 5/2/2024 5/2/2024 Non- Standing by for county attorney's office notice. os Compliant MarinosCharles 05/02/2024 9:48 AM Re -Inspection Charles.Marin 5/16/2024 5/16/2024 Escalate to Violation remains, as per supervisor os Legal instructions, preparing hearing packet for submittal. MarinosCharles 05/16/2024 1:14 PM Assign Hearing Type Charles.Marin 5/16/2024 5/16/2024 Special os Magistrate Hearing OE Supervisor Review (SM) BradleyHolme 5/17/2024 5/21/2024 Complete Please see attached hearing packet for s review and submittal. CM88 CE Legal Review IetourneauJ 5/21/2024 5/21/2024 Schedule I reviewed the packet and gave it to the for SM/CEB Hearing Team. JL#34 Schedule Case for Hearing Ashley.Eoff 5/21/2024 5/21/2024 Complete Case scheduled for June 7, 2024 OSM Hearing .AE Generate Hearing Notice (CE) Ashley.Eoff 5/21/2024 5/21/2024 Complete Hearing Notice Service/Posting Charles.Marin 5/22/2024 5/23/2024 Complete Last day to post May 23, 2024 .AE os Property posted on 22May2024 at 1441. CM88 CE Mailing Ashley.Eoff 5/22/2024 5/22/2024 Complete NOH for the June 7, 2024 OSM Hearing mailed reg. and evidence packet mailed cert. .AE CE Staff Review Ashley.Eoff 5/23/2024 5/23/2024 Complete AOM AOP NOH attached .AE Affidavit of Service/Posting Charles.Marin 5/23/2024 5/23/2024 Complete os CE Staff Review Ashley.Eoff 5/23/2024 5/23/2024 Complete Please scan and notorize signed AOP. CM88 Pre Hearing Inspection BradleyHolme 6/6/2024 6/6/2024 Complete 6-6-2024 No permit on file to address the s pump house and related utilties. BH91 Business Management & Budget Office g EXHIBIT - 002 - PAGE - 001 CODE ENFORCEMENT - COLLIER COUNTY, FLORIDA Office of the Special Magistrate BOARD OF COUNTY COMMISSIONERS, COLLIER COUNTY, FLORIDA, Plaintiff, vs BUOYANCY LLC, Respondent(s) NOTICE OF HEARING Case: CESD20240001061 PLEASE TAKE NOTICE that Pursuant to Section 162.06 and 162.12, Florida Statutes, and Collier County Ordinance No. 07-44, as amended, you are hereby ordered to appear at a public hearing before the Office of the Special Magistrate on the following date, time, and place for the violation below: DATE: 06/07/2024 TIME: 09:00 AM PLACE: 3299 Tamiami Trail East Building F, Naples, FL 34112 VIOLATION: Improvement Prior to Building Permit 10.02.06(8)(1)(a), 10.02.06(B)(1)(e) and 10.02.06(B)(1)(e)(i) LOCATION OF VIOLATION: 2225 23rd ST SW, Naples, FL 34117 SERVED: BUOYANCY LLC, Respondent Charles Marinos, Issuing Officer RESPONDENTS ARE REQUIRED TO APPEAR AT 8:30 AM FOR A PRE -HEARING CONFERENCE HEARINGS TO BEGIN AT 9:00 AM PLEASE TAKE FURTHER NOTICE that the alleged violator may produce any and all documents, witnesses and/or evidence to be relied upon for the testimony given at the hearing. Documents will consist of the original and three copies. Alleged violators have the right to be represented by an attorney. PLEASE TAKE FURTHER NOTICE that Requests for Continuances will not be considered if not received by the Secretary to the Office of the Special Magistrate at least five (5) business days prior to the date set for the hearing. IT IS FURTHER ADVISED that Ordinance No. 07-44, as amended, be reviewed prior to your attendance at the hearing to include emphasis on Section Eight relating to the appeal process. Ashley Eoff COLLIER COUNTY CODE ENFORCEMENT 2800 North Horseshoe Drive Naples, Florida 34104 (239) 252-2496 Telephone Anyone who requires an auxiliary aid or service for effective communication, or other reasonable accommodations to participate in this proceeding, should contact the Collier County Facilities Management Division, located at 3335 Tamiami Trail E., Suite 101, Naples, Florida 34112, or (239) 252- 8380, as soon as possible, but no later than 48 hours before the scheduled event. Such reasonable accommodations will be provided at no cost to the individual. NOTIFICACION: Esta audiencia sera conducida en el idioma Ingles. Servicios the traduccion no seran disponibles en la audiencia y usted sera responsable de proveer su propio traductor, para un mejor entendimiento con las comunicaciones de este evento. Por favor traiga su propio traductor. AVETISMAN: Tout odisyon yo fit an angl&. Nou pan gin moun you M tradiksyon. Si ou pa pal6 angl6 tanpri vini avbk you int6pret you pal6 you-ou. EXHIBIT - 003 - PAGE - 001 INSTR 6600672 OR 6404 PG 3669 RECORDED 10/14/202_4 11.20AM PAGES 1 CLERK OF THE C!RCU!T COURT AND rnMPTROLLER CO Ter County COLLIER COUNTY FLORIDA REC $10 00 Growth Management Department 2800 N. Horseshoe Dr., Naples FL 34104 1 239-252-2400 NOTICE OF COMMENCEMENT State of FLORIDA County of COLLIER A. Permit No. B. Parcel/Tax Folio No. 45960240004 1. Description of Property (legal description of the property, and street address if available): All of Tract 5 of GGE, Unit 195 recorded in Plat book 7, Page 102, except rear subdivided parcel, totaling 3.371 acres., commonly known as 2225 23rd Street SW 2. General description of improvement (must be work scope specific and match the Permit): After the fact permit application for changes forinleriorchanges.demolishwellhouse, constructne%vwellhouse, upgradeelectricalservice. 3. Owner information or Lessee information if Lessee contracted for the improvement: a. Name: Buoyancy, LLC b. Address: 2805 Horseshoe Drive S. #10, Naples. FL 34104 c. Interest in property: Fee simple d. Name and address of fee simple titleholder (if different from Owner listed above): 4. Contractor information a. Name: Jasinski Builders. LLC b. Contractor's Address: 2805 Horseshoe Drive S, #10, Naples, FL 34104 c. Contractor's Phone Number: 239-231-1166 5. Surety lYes FRI No (if applicable, a copy of the payment bond is attached): a. Name: ❑ N/A b. Address: ❑ NIA c. Phone Number: ❑ N/A d. Amount of Bond: $ ❑ NIA 6. Lender information a. Name: Shelipoint Mortgage Servicing ❑ N/A b. Phone: 800-365-7107 ❑ N/A c. Lender's Address: PO Box 7050 Troy, MI 48007-7050 ❑ NIA 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7. a. Name(s): Kristen Jasinski ❑ NIA b. Address: 2805 Horseshoe Drive S. #10. Naples. FL 34104 ❑ N/A c. Phone Numbers of designated persons: 239-231-1166 ❑ NIA & a. In addition to himself or herself, Owner designates ❑ N/A of ✓ NIA to receive a copy of Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. b. Phone Number of person or entity designated by owner: ✓❑ NIA 9. Expiration date of notice of commencement (the expiration date will be 1 year from the date of recording unless a different date is specified): WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FIN G, CONSULT Wff±f_ UR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF CO kff T. Signature of Owner or Lessee, or Lessee's Authorized Signatory's Printed Name an�1 Tit e/Office Officer/Director/Partner/Manager �4" &,dy,*-v�j (LC The foregoing instrument was acknowledged before me by means of Niysical presence rQonline notarization thisl�day of 2QWbY rJ^�SI�/ (name of person) as C �Y (type of authority, e.g, officer, trustee, attorney in fact) for BY d y Y(t4 L e _ (name of party on behalf of who ins r ent was executed). CRYSTAL K. KINZEL, CLERK OF THE CIRCUIT COURT & COMPTROLLER I (Signature of Deputy Clerk) (Printed Name of Deputy Clerk) Notice of Commencement - 1.20 (Signature of Notal Public - State of Florida) (Print, Type, or Starrla commissioned Name of Notary) ratification IdenWE£ib 1 rdA&NSK1 �Notary Public -State of Florida Page 1 of 1 ,,` Commission # HH 636967 � My Commission Expires October 04. 2028 EXHIBIT - 004 - PAGE - 001 2800 N. Horseshoe Drive Co Ter County Naples, FL 34104 rCnG Ah Management DeMrinw.nt (239) 252-2428 October 25, 2024 Notice: A Accessory Structure Permit, reference number PRAC20241042897, Has Been Applied for Listing you as a Primary Contractor or Subcontractor. This application was submitted through the GMCD Public Portal by a Portal account registered to Kristen Jasinski, using email address kristen@naplesfloridavacationhomes.com. The work site address on the application is 2225 23rd ST SW, Naples. If you were added to this application without your knowledge or authorization, please contact the primary contractor immediately. Primary JASINSKI BUILDERS, LLC Contractor 2805 HORESHOE DRIVE S, 410 NAPLES, FL 34104 KRISTEN@NAPLESFLORIDAVACATIONHOMES.COM EXHIBIT - 005 - PAGE - 001 October 26, 2024 Mr. Richard Vazquez Collier County Building Department Via email: Richard.Vazquez@colliercountyfl.gov colliercountyfl.gov TEL: 239-252-2576 RE: Response to Initial Incomplete Notice PRFH20241041232 Hello Richard, In response to your Initial Incomplete Notice letter dated October 16, 2024 and your subsequent letter dated October 17, 2024: 1. Yes you can remove the well house 09/27/24 eseal.pdf document from this application. We have submitted separate permit applications to build this accessory structure (PRAC20241042897) and also to demolish the old well house (PRDM20241042895). 2. The Product Index Sheet was re -uploaded to your portal on 10/17/24 Just for the record I also sent confirmation by email on October 22, 2024 letting you know if was okay to remove the well house portion from the plan. Sincerely, k�44—� � Kristen Jasinski License # CRC1333281 2805 Horseshoe Drive S, #10, Naples, FL 34104 239-231-1166 EXHIBIT - 019 - PAGE - 001 EXHIBIT - 006 - PAGE - 001 COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DEPARTMENT i BUSINESS CENTER 2800 N. Horseshoe Drive, Naples FL 34104 1 Phone (239) 252-2400 Initial Incomplete Notice Incomplete Initial Submittal Notice October 29, 2024 Kristen Jasinski RE: Permit Number: PRAC20241042897 Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples Job Address: 2225 23rd ST SW, Naples A sufficiency review of the submittal package for the above referenced application indicates the following items are deficient. These items will need to be submitted as soon as possible so that we may continue to process your application: Reviewed By: Richard Vazquez Phone: (239) 252-2576 Email: Richard.Vazquez@colliercountyfl.gov 1. Construction Plans - Well House Plans - Missing digital signature data - "Please be advised, changing the name of the original document adding or extracting pages after the document has been digitally signed will make the digital signature disappear or invalid" 2. Storm Water Plan - Missing - https://www. colliercountyfl. gov/home/showdocument?id=72831 3. Product Index Sheet - 4. Specialty Engineering and Specification Sheets - Missing Truss or Deferral letter 5. Vegetation Removal Affidavit - Any new construction, additions, accessory structures, or fences that are not within a subdivision (PUD) require a vegetation removal affidavit signed by qualifier or applicant. Form can be found here: https:llwww.colliercountyfl.gov/home/showdocument?id=38241 EXHIBIT - 007 - PAGE - 001 A final sufficiency review for permit application PRAC20241042897 has been completed and deemed insufficient. Failure to respond to this notice within 7 calendar days will result in a Final Incomplete Notice that allows for an additional 7 days to respond. Failure to respond within the aforementioned 14 days will result in this permit application being set to a "Denied" status and is considered closed. A new permit application covering the proposed construction shall be obtained before proceeding with the work. For electronic submissions, outstanding documents can be submitted online. You will need to click on the "Submittals" button near the bottom of the page to upload to each submittal requirement. Your application can be accessed here: was:Hcvl2ortal.colliercounLy 2ov/CitvViewWeb/ EXHIBIT - 007 - PAGE - 002 COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DEPARTMENT I BUSINESS CENTER 2800 N. Horseshoe Drive, Naples FL 34104 1 Phone (239) 252-2400 Initial Incomplete Notice Incomplete Initial Submittal Notice October 29, 2024 Kristen Jasinski RE: Permit Number: PRAC20241042897 Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples Job Address: 2225 23rd ST SW, Naples A sufficiency review of the submittal package for the above referenced application indicates the following items are deficient. These items will need to be submitted as soon as possible so that we may continue to process your application: Reviewed By: Richard Vazquez Phone: (239) 252-2576 Email: Richard.Vazquez@colliercountyfl.gov 1. Construction Plans - Well House Plans - Missing digital signature data - "Please be advised, changing the name of the original document adding or extracting pages after the document has been digitally signed will make the digital signature disappear or invalid" 2. Storm Water Plan - Missing - https://www. colliercountyfl. gov/home/showdocument?id=72831 3. Product Index Sheet - As of 0110112020, a product approval index sheet is required to be provided for any permit submittal containing product approvals. The product approval index sheet can be found here: https:Ilwww. colliercountyfl. gov/home/showdocument?id=76659 4. Specialty Engineering and Specification Sheets - Missing Truss or Deferral letter 5. Vegetation Removal Affidavit - Any new construction, additions, accessory structures, or fences that are not within a subdivision (PUD) require a EXHIBIT - 008 - PAGE - 001 vegetation removal affidavit signed by qualifier or applicant. Form can be found here: https:llwww.colliercountyfl.gov/homelshowdocument?id=38241 A final sufficiency review for permit application PRAC20241042897 has been completed and deemed insufficient. Failure to respond to this notice within 7 calendar days will result in a Final Incomplete Notice that allows for an additional 7 days to respond. Failure to respond within the aforementioned 14 days will result in this permit application being set to a "Denied" status and is considered closed. A new permit application covering the proposed construction shall be obtained before proceeding with the work. For electronic submissions, outstanding documents can be submitted online. You will need to click on the "Submittals" button near the bottom of the page to upload to each submittal requirement. Your application can be accessed here: ht sn.//cvportal.colIiercountyfl.gov/CityViewWeb/ EXHIBIT - 008 - PAGE - 002 Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT Receipt Number: 20241257794 Transaction Number: 2024-099464 Date Paid: 10/30/2024 Amount Due: $219.00 Payment Details: Payment Method Amount Paid Check Number Credit Card $219.00 3935613224 Amount Paid: $219.00 Change / Overage: $0.00 Contact: Kristen )asinski 2805 horseshoe drive s, suite 10 Naples, FL 34104 FEE DETAILS: Fee Description Reference Number Original Amount GL Account Fee Paid Inspection Fee PRDM20241042895 $65.00 $65.00 113-138900-322110-000000 Site Engineering PRDM20241042895 $150.00 $150.00 131-138327-322490 BCAI PRDM20241042895 $2.00 $2.00 113-000000-208820 DBPR Surcharge PRDM20241042895 $2.00 $2.00 113-000000-208800 Cashier Name: cvmanager Batch Number: 13531 Entered By: Stephanie. Burgos EXHIBIT - 009 - PAGE - 001 A" I-- 0 "0 (D -n m x > _0 (D U) C) 0 C) 0 - (D > 70 =- > n 0 w (D u-) Ul n Q.ct n c -0 (D 0 I n 0 n' rt n 0 I 0 D U m o- 0 0 D 0 0 --h * n n 0 o --h w rt w rt w r-r 0 (D 0-1 3 1" 0 " I" r,,j 0 �v 0 m -n o -0 0 0 0 NJ (D (D (D C (D ;U [\.J r\j 3cn3 0 o (D 0 =- f`j NJ P-i N V) o 0 0 0 0 zT o 0 < rj rj i,.j r�j a 0 GJ n F\j 3 -.P, Ul -4\- -P- F-A 0 0 :3 (D C) cu 00 LU rt (D 0 CL ID 0 (D (D 0 (D (f) 0 f- 1.0 (D EXHIBIT - 010 - PAGE - 001 Iy G.—mth Management Departm•en; The stormwater plan worksheet must be completed if the building permit does not require a certified site plan. This form is not necessary for building permits that require a certified site plan. Some information required to complete this worksheet may be available from sources such as the property {{ appraiser's website. Z 2 Z�_ ��.4 Sl ! 9-->T S&O X(- rlS;n, Lot Size 1 Lot width 0 2_ 1 ft 2 Lot depth 7 ft 3 Lot Area (multiply lines 1 and 2) 3_�' 1 ft, Impervious Area 4 Existing impervious area (see de inition - l ftz (Y includes house, driveways, pool decks, etc.) / , 7 / See definition on page 1 5 Proposed additional impervious area /i7,�7 I ft2 6 Total lot impervious area (add lines 4 and 5) y= •w[ I ft, Stormwater Plan Type 7 Percentage of impervious area (line 6 divided 2- 6, Z i % by line 3) 8 Required Stormwater plan (compare line 7 to Table 1 for stormmwater plan thresholds): I rl Type I Stormwater Plan (See LDC section 6.05.03 D.1) ❑ Type II Stormwater Plan (See LDC section 6.05.03 D -ja S /V,/U SU, c12,--- /2, �. zS/. P, ,�� P_'A � 2, z fJ V`z t 7 Page 4 of 4 EXHIBIT - 011 -PAGE - 001 M 2800 North I lorseshoe Drive _I i'er Cow.-pt�y Naples, FL 34104 v'x ... 239.252,2400 Gr,-,,VJi Management4Departrrl2nt www.colliercountyfl.gov Vegetation Removal Affidavit The purpose of this affidavit is to inform you of the vegetation removal regulations. By signing this affidavit you are stating that you will comply with the Collier County Land Development Code (LDC) Section 3.05.00. The Collier County Land Development Code Sec. 3.05.00 states it shall be unlawful to remove, or otherwise destroy, vegetation, which includes placing of additional fill, without first obtaining a vegetation removal or vegetation removal and fill permit from the Growth Management Division. • No vegetation removal permit shall be issued until all applicable federal, state, and county approvals have been obtained. These approvals may include, but are not limited to: Building permits; Special Treatment (ST) development permits; State and Federal agency (USACOE, FDEP, USFWS, FFWCC), permits or approvals for impacts to wetlands or listed species; or other applicable agency reviews, permits, or exemptions; other county approvals. • Native vegetation cannot be removed before the ISSUANCE of a Building Permit which allows for clearing up to ONE ACRE. Parcels located in Rural Fringe Mixed Use district, Big Cypress Area of Critical State Concern, Special Treatment (ST) overlays or with wetlands may not be able to clear up to ONE ACRE. Additional reviews or permits are required for these areas. • Informal Wetland Determinations can and should be obtained from the County or FDEP for properties in the Golden Gate Estates or outside approved subdivisions. Clearing in wetlands will require a permit from the FDEP, prior to clearing of vegetation. • If clearing is not covered under the building permit issued for your home, a Vegetation Removal Permit (VRP) will be required. One exception is that a VRP may be issued in conjunction with the issuance of a perimeter fence permit. Note: Native vegetation includes ALL woody non -exotic trees, shrubs, and ground cover. Lot Area (Acres): 277 1, a L. } -PS Proposed acreage to be removed: Existing acreage previously removed: (AN(LN`r 'V "J Total cleared area (Proposed and Existing): �� If the total cleared area exceeds ONE ACRE a Vegetation Removal 1 Permit (VRP) will be required. Failure to obtain a VRP and/or abide by Ithe LDC mayresultin a violation and fines. IIII !vo 6,? fepk0 � CC-V e ��w L•L� ttic� ,veLC Signature of Applicant: Date: state of t c' County of �U L"��`,, Tnhgforegoing instrument was acknowledged before me by means of LAY, physical presence or ❑ online notarization this 6 day of 20 Z` , by (printed name of owner or qualifier) KJ K,-e f— Such pelson(s) Notary Public must check applicable box: L,�'/ ""' WESLEY JASINSKI Are persona ly known to a ,,�;�.. ,, _ Notary Public -State of Florida ❑ Has produced a curren driv rs license = Commission 0 HH 536967 ❑ Has produced - as identification. %?pnaP My Commission Expires October 04, 2028 Notary Signature: s i Permit Number. 2b 2 t ((O Permit Type: ' 1 u SS C+ c ��T LlC7k i Location Address: Folio: 1-fS96 v 2o(�a Applicant's Name- �f I �a ti 71 Q � Contractor Name (if applicable):cS,t State Registration No.:"j 3 3 Zg(' `./ Vegetation Removal Affidavit EXHIBIT - 012 - PAGE - 001 I LD E RS November 6, 2024 Mr. Richard Vazquez Collier County Building Department Via email: Richard .Vazguez(cDcolliercountyfl gov TEL: 239-252-2576 RE: Truss Deferral Letter 2225 23rd Street SW PRAC20241042897 - Application for new Accessory Structure (well house) To Whom It May Concern, Truss Drawings are being prepared by the truss company. We will submit the truss drawings when they are available and prior to issuance of the permit. We request that the permit issuance is deferred until truss drawings are submitted. Please proceed with the plan review related to our application for building a new accessory structure at 2225 23rd Street SW. Sincerely, cw� ?I ��� Kristen Jasinski License # CRC1333281 2805 Horseshoe Drive S, #10, Naples, FL 34104 239-231-1166 EXHIBIT - 013 - PAGE - 001 COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DEPARTMENT I BUSINESS CENTER 2800 N. Horseshoe Drive, Naples FL 34104 1 Phone (239) 252-2400 Initial Incomplete Notice Incomplete Initial Submittal Notice November 07, 2024 Kristen Jasinski RE: Permit Number: PRAC20241042897 Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples Job Address: 2225 23rd ST SW, Naples A sufficiency review of the submittal package for the above referenced application indicates the following items are deficient. These items will need to be submitted as soon as possible so that we may continue to process your application: Reviewed By: Richard Vazquez Phone: (239) 252-2576 Email: Richard.Vazquez@colliercountyfl.gov 1. Construction Plans - Well House Plans - Missing digital signature data - **Please be advised, changing the name of the original document adding or extracting pages after the document has been digitally signed will make the digital signature disappear or invalid** 2. Product Index Sheet - As of 0110112020, a product approval index sheet is required to be provided for any permit submittal containing product approvals. The product approval index sheet can be found here: https://www. colliercountyfl. gov/home/showdocument?id=76659 A final sufficiency review for permit application PRAC20241042897 has been completed and deemed insufficient. Failure to respond to this notice within 7 calendar days will result in a Final Incomplete Notice that allows for an additional 7 days to respond. Failure to respond within the aforementioned 14 days will result in this permit application being EXHIBIT - 014 - PAGE - 001 set to a "Denied" status and is considered closed. A new permit application covering the proposed construction shall be obtained before proceeding with the work. For electronic submissions, outstanding documents can be submitted online. You will need to click on the "Submittals" button near the bottom of the page to upload to each submittal requirement. Your application can be accessed here: hht sn ://cvportal.colliercountyfl.gov/CityViewWeb/ EXHIBIT - 014 - PAGE - 002 OADE MIAMI.MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street. Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/eeonomv Santafe Tile Corporation 8825 NW 95`h Street Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. l DESCRIPTION: Santafe Spanish IS' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 19-1021.30 and consists of pages I through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-0614.05 Expiration Date: 02/01/26 Approval Date: 07/01/21 Page 1 of 5 EXHIBIT - 014 - PAGE - 003 ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Deck Tyne: Roofing Roofing Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Santaf6 `S' Clay Roof L = 18" TAS 112 One piece high profile clay roof tile equipped with Tile W = 11.1" Type I two nail holes. For nail -on, batten (4/12 min slope); Thickness = 0.39" Grade 1 and mortar set and adhesive set applications. Trim Pieces l = varies TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, w = varies ridges and valley terminations. Manufactured for varying thickness each tile profile. 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 25-7205-1 TAS 101 March 1995 Project: 07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix II (Nail -On) 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails P 0647-01 TAS 108 Aug. 1994 (Mortar Set) P 063 1 -01 PA 108 July. 1994 (Mortar Set) NOA No.: 21-0614.05 Expiration Date: 02/01/26 Approval Date: 07/01/21 Page 2 of 5 EXHIBIT - 014 - PAGE - 004 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 PRl Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 2353-71 TAS 101 09/22/03 2353-93 ASTM C 1167 07/18/05 2353-4 Restoring Moment Aug. 1999 American Test Lab of South Florida RT0624.01-15 ASTM C1167-03 07/01/15 RT1008.01-20 ASTM C1167 10/16/20 PRI Construction Material Technologies COPO-002-02-08 TAS 101 10/12/16 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Mechanically attached tile; minimum slope 4/12. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.8 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations NOA No.: 21-0614.05 Expiration Date: 02/01/26 Approval Date: 07/01/21 Page 3 of 5 EXHIBIT - 014 - PAGE - 005 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe 'S' 6.7 1.5 1 0.958 Table 2: Aerodynamic Multipliers— X(ft3) Tile Profile X (ft3) Batten Application X (ft3) Direct Deck Santafe 'S' 0.274 0.297 Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf) Tile Profile 2"A 2" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Santafe 'S' N/A 5.90 N/A 5.82 5.73 5.69 5.56 5.53 5.32 5.29 5.03 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck Battens Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.161.2 N/A Two #8 Screws 38.28' N/A One #8 Screw w/ Clip 57.311.2 N/A Two #8 Screws w/ Clip 57.60' 61.77' 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application 3 Minimum Attachment Resistance Santafe 'S' Tile Bond 38.94 Pol set AH 160TIl 33.15 3. See manufactures component approval for installation requirements. 4. Paddy placement of 10.4 grams of DuPont de Nemours, Inc. Tile Bond Roof Tile Adhesive 5. Paddy placement of 9.4 grams of ICP Adhesives Polypro AH 160TM Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application 3 Minimum Attachment Resistance Santafe 'S' Pol set AH 160TI 66.5 6 Pol set AH 160TM 63.8 7 DAP Foam Touch N Seal Storm Bond 2 1008 6. Paddy placement of 63 grams of ICP Adhesives Polypro AH 160TM 7. Paddy placement of 24 grams of ICP Adhesives Polypro AH 160TM 8. Paddy placement of 45 grams DAP Foam Touch N Seal Storm Bond 2 NOA No.: 21-0614.05 Expiration Date: 02/01/26 Approval Date: 07/01/21 Page 4 of 5 EXHIBIT - 014 - PAGE - 006 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Santafe 'S' Mortar Set 23.6 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING When using one screw >e this hole. "SANTAFE S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 21-0614.05 Expiration Date: 02/01/26 Approval Date: 07/01/21 Page 5 of 5 EXHIBIT - 014 - PAGE - 007 R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation Fiber -Classic and Smooth -Star Exterior Swinging Exterior Door 118 Industrial Drive Composite Edge Glazed Fiberglass Double Door Doors Assemblies Edgerton, erton, OH 43517 w/ or w/out Sidelites Phone 419.298.1740 Inswing/Outswing 'Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM Ell996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.12 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber -Classic & Smooth -Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.12 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 01460274 TEL 01460131 TEL 06-0831-1 TEL 01461612 TEL 01461939 2. Miami Dade NOA 16-1117.01 17-0712.05 Test Standard ASTM E1886-05, E1996-05 ASTM E330-02, E331-00 ASTM E1886-02, E1996-02 ASTM E330-02, E331-00 AAMA/W DMA/CSA101 /I. S.2/A440-05 ASTM E1886-02, E1996-02 ASTM E1886-05, E1996-09 ASTM E330-02, E331-00 ASTM E330-02, E331-00 ASTM E1886-05, E1996-09 Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc V.K. Wright Materials Testing Butacite® PVB Interlayer (Kuraray) Saflex® PVB Interlayer (Eastman Chemical Company) d by,�:e��►vrerrrrr� 3 No. FL-20468.12 RW BDrawing No. uilding Consultants, Inc. (CA #9813) �; G& Sealed �%� ��sosyndon F. Schm dtb P.E. 4. Calculations Prepared by eee 1• �'16 OeUgned & Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) No 43409 *LIMdon F. Schmidt, P.E. 5. Quality Assurance e Certificate of Participation issued by National Accreditation and Managemegt,O Institute, certifying that Therma Tru Corporation is manufacturing products p.13 STATE O within a quality assurance program that complies with ISO/IEC 17020 and 1.♦0�.,_,c . ;a Guide 53. �i♦ F •L O R �t;• ♦ is �O Lyndon F. Schmidt, P.E. ♦��eos BO N Fero 890� FL PE No. 43409 12/14/2017 Sheet 1 of 1 EXHIBIT - 014 - PAGE - 008 CHIs ...o mg 'M'G 91oz CA £L06 'ON YO 3d8j SNOISIA38 Lel6-669'£L9 oN ...4d S31ON IV2GN30 V S3?U Mdcl ^I s6se�N j 'o-Vlon 'ocz --S •o'd N01S30 'NOI1YA313 IWJIdA1 Y ttt Lil�7j�LS1NV11nSNOO ONIM.— '-Al8W3SSW NO Ladd N F- -� .tea, o 60Yfi 'ON 3 d 21000 SSW10213813 o Z a )plw4.s 'j uopu.F1 ma-WW83Hi _ d0311118 :Ze ve+od.,d nwwruoa10l10021d 3 S B U60l01 60Kil'ON L��nrnuttta � a o � o .0 z Nz_ W3 K � � 0 > 0 L-- 0 ^ Ln a + + t O O Cl W z �3 Xo az w = N X w w O r-z o p 10 10 Lo i' t t L O O a a c (JNIMS1f10) 1H`J13H 3WW211 m m L 0 p a :a 'W'0'XWW,Sl'L6 ,a ,4 � o u fONIMSNI)1HO19H 3WW61 � 'W'0'XWW •86 h 3t z a x z `o `w x x x 4) N d U � N O u O `0 � � 9 L m o � � a E ME E � c LLJ-� m E o o J c= oo 0 4) W _ E 6 m ,^ w o a o o E ® W y 3 v w o v o d a 05 om� �O -C J 01� C Ex 8Z5 acr O O (n C o O v cc oa�i �cv oy do QC/D m H o cl c0 o0 0o 06 U W ? oa z 8A c 2 n n 0 � c�v o o 0, 4 N o o Oc N Cl V 015 W V u� L LL 0^$ V E O y U C (l Q N L C y p E �/ Z U O C o v C F° U a Q. oU o E S; E..moo O an' o Ooo,_ Ti„ >BTiu �_ W .f0 > L U O U N O C m? a P 3 H a m °° = o o. LE AB 31W0 ON Nf Oflj LLOZ 03 479 Ol 31NOdf1 L{ LL L l NOLCWION l3NVd 03SS30321 ONW Nf 'O '0 ,Z L-S 1lOBOb30 OOVLL SL Ol Z 1W 310N NOLLdO l3NVd i1000 ',13a BL 80 OL £ m Z a o c _ _ m'm � 5 o�ov U � s hm ° .� Quo€m a � „ uc�u $ ua.rco-�� ¢ z'm 0 CC CC � �' 0 c p� o O 4�I � p� O N OC"uxxx> m xU m b'9960Z--u'6Mp'9-b'9940Z-ljUNam L1- (L[OZ) 8960Z li\�wreio - O\ajp dw� - pW.j SS N 11 tl09M 9960Z.1j\sjmwddy Impuid eppgj - V\1N3NVWH3d N1 euva4L\s7uai0\:y 091 Hie ao' u,8 -ro•a 9ioz0 £l98'ON 'YO 3de3 SNOISIA38 L818'899'£l9 ;,ON cuoyd A9 31VO ON m v '.I 989££ 1i :—Ill-A 'o£z xo8 'O'd M' SlIV130 13NVd 8000 Nr oad LioZ a3 W9 Ol 31Vad0 Ll Ll L I N, LS �c co )SLNVIVISN00 oNia-itne" "�J :Al8W3SSV 80 1MYd NOLLVION 13NVd a3SS303N QNV o Z '� 0 0 '1VN0/ ��t, Hr •0 0 .z I—s 110eav3a aovu st of z m w wl ,.. 60Y£4 -aN -3'd 8000 SSV1983813 LY 31ON NOLWO 13NVd 8000 'A321 9l 80 Ol £ o '� Vat�2y'•. ��� iPlwyoB j uoaury f181-VYi83H1 gg v dO HBOi zA6 P—dud .iuow—a -,=008d S 3i B 1/60//01 *2C� a O Z 604E4' N o �OOQ/WH`JS•>j U :x a U (� U 0 O of OZ Zm< 0 O w U O vUm'i11 ud_ KUU wz o 0 .a�-- VOO Z N O � W N Z V OII II I I� 00 b9'0 O pl �I V _ M N Z ti N o _ � 3 = ,s•s I NN 00 p - + w i., Ed v N O 1 Iq� a O „tLI � cai 3 N O v �u U o_ Oa iU NN O U iHOeH 13NVd KOO "X" ..90'96 y 0 . D o oW 00 to 0 $j w Uv h N � N N U COI Q iHO13H 19NVd 8000'XVW ,SL'S6 µ� w .09 w O O i C5 o O of br M N �0 o Z m 4 Om w j � O O 1HJ9H 13NVd 8000'XVW.SZ'96 9'Z'6mP'9-v9960L-1d\iNRnno-\LZOZ) 8969Z -:)\.Ilsodwo7-yedun SS?JJ-LNa9M 6960Z-131Aen ddyyrpwd ePPOH-VUMNVWU3d NL 2-41\54-11M.y EXHIBIT - 014 - PAGE - 010 £l96 'ON o'O 3de3 L616'599'£{9 :'ON ouo4d 9642E 'td 'owlo^ •02Z xO9 'O'd /�j(/�J� SNOU 313 SNOISIA3a a A9 31VO ON Nr OEU LLOZ 03 439 Ol 31YOdn Ll Ll L NOIIVION 13NVd 03SS3O3a ONY `o O;S1NV1lnSN00 ONI0llne ' "w ,\\ AleYL3SSd a0 laVd z 8000 SSV10a38Li >jr o '0 ,z t-s 1ioeGV30 00Yu s� o� z ` 506£4 'ON '3'd *.A o R I �I i 310N NOLWO 13NVd 8000 'A3a 9l 90 Ol £ �\ :'•rCWOjy'•. i 3PIwyoS uopu.(l nal-Ywa3Hl 6 ` dO RMS 4(B p..dud n�• —0 �JanOoad -al/60/OL 60KI, -ON j ' �i�0/ �N....... 'I",�"Wior. �`��. 0 c � c ru o a Ov3m`o c y o m O u w � y m`oo a m C 0 0 0 9'E '6MP'9-b'B960Z-7411N3MNN ILTOZ) 9960Z ldls6upnei0 - 7\allsodwo7 - }ietlwI 55 7j ll N08M 8960Z-1d\slennitltltl l�npay eppalj - tl\1N3NVWL3d Nl euua41157ua1p\:y EXHIBIT - 014 - PAGE - 011 o.1 siHdi—.10 me wu 6ioze £l96 *ON 'o O uddai LSt6'6S9'£L9 :' N a 4d (Nona XZ) SN011035 SSOaO SNOISIA38 ^n O6S££ 'ld 'ooNl-A 'O£Z xo9 '0'd /I/I IVOLL83A 2P IVINOZ180N LO 'S1NV1lnSN00 ONIOl109 r�7o,,. :Al8V13SSV 80 1NVd z o 8000 SSVl0a391d idN 6O*CV 'oN 3'd . ` M-4oS .j U.P. nal-VWa3rU 1 .403LV12 Q : .M Pwodud ��ownooa :i3noo8d 3 SS E =Bl/60l0f 6046V-ON�GC�! f� p �m W 5 G _ m uVi E N 'F N OI O OL U J I �xu Q 3° � N oe Z n S �O u N,W IM PUn� � Met 0 U O O o a w Q 0 z w O w � E ' ^ W H e N C C Ux o 30 N Ouj v uj v o � w m p H E a U o v H cn y .� � N � � u U N ,a m3 N U 0 N 005 m zz 0 J N C a " ° n Z a 7m -'- w J.8 EXHIBIT - 014 - PAGE - 012 31V0 ON Nr Oad LGOZ 03 479 O1 31VOd0 Ll Ll L NO11V10N l3NVd 035S303a ONb' Nr 'o •o ,z t-s tloaaV3a aav a sl of z 1W 310N N011d0 l3NVd a000 'A31J 8{ BO OL £ £l96 'ON 'YO 3dSA L616'699'£l9 :' N e004d (Nons XL) SNOLL03S SS060 SNOISIA3?1 to a 31V0 ON .,,,, , Aq S6S££ ld I A 'O£Z xog •O'd /I'f 9NIQune/,ti�j 1V0I1a3A V IV1NOZIHOH 'A18w35SV i10 1N0'dVd .- `4 �' vI Y t� '' ^I 3 4l9 O1 31Vadn Ll Ll L l a35S303t1 ONV ```t�tl�yj,/S1Ntl1�nsNo� v Mr-S 110BCIV30 OOV Ma-LON LL Sl �NO LLB in 13Wd 8000 'A38 9l 90 0! f 60i£f 'oN '3'd jCW02y' •. �� M-4oS •d .-Pu(1 8000 SSY1083OLI ()2ll-Vw213H1 O 1 € j KOHL= :As pwodud 4uaa—a :10naoad 3 u .aN fiarev `m W W s Z 0 Q Q U Ub� v a 0 z Xt EEc N x P N eq h `LI t5 U e• LD e . od LLJ O Z Q t. N V gg N�C . e uX U 3a 14 Sio OC QI .- N O f V W r O Q Q L Q K m 0 x E O I Q N U 5 O V SW.e E N C N a u�V P O �xN V c N O� x �-o 0 ° v .. N w W^ v e e p. Z i 9.5'9Mp'9-v9mz--wUN3aro - UTOZ) 09KZ ld\SOUlmeiO - 0\;11SodwoO - yedW1 SS Od 11 L09M 9940Z--W\sj—ddV pnPwd eRcid - VUN3NVWnd Ml euu WStualDV d EXHIBIT - 014 - PAGE - 013 £!96 'uN YO 3d93 -N ...4d (AMOSVW 01 103NIa) SN01103S NOISIA3H L6L6'699'£L9 ssse£ 1d 'ooNlon 'oez xo9 'o'd 'S1Nb'11f15N00 1V011N3/! V IVINCZ180H :A19N3SSV A9 Nf OEId L! OZ 03 439 O1 31VO#Ll�ll -13NVd 31V0 ON v ` ` ONIOlif18 11�%� NO 1HVd NOLLVION 03SS3038 O/// '0'0-S Hf 1l0ElOV3OOZ/'60Y£Y 'oN '3'd VCWoZy •., 3PIw4oS 'd uopwcl a00a SSVI08381-4 M-MOH1 1W 310N NOLLdO l3NVd dOOo 'n F d031K1D :H3 P—d-, -i3nOO8d -91/60/01 sovev'ON 'XHW D •..4GN30r.: j I �S' l �SLV ,, a�WHoS z - y r .\`� U U iE D a U c NO 10) 3 O x ho �O �O 0 !V. E E 0 w+ y oa N w o U • U C 0 Q aJ C >�o O y Z a g u�� U Lij Z Uc N0 'NIW NO o ,S'I W & z x NS o z'_ +I °a H Y Y K N 00� Q y 'X'dW,S'l D SU N 3 3 `1 .NIW E w �Sl'l a y � U � a•o D D O P u iE W c Z 20 Oom o Oz n E o OC �,� O � awe U_C o 3 o v O _ - V0 Z ado > �0' _O o U y O u f� U ° ° a0� o pom NIW 0. go ,SL l � Z p: W Z )!vw S'l o `� cV •o 9'9'6mp'9-b'8960Z-1411Nann3 - UTOZ) 890OZ 1d\s6ulmei0 - O\.jp dwo3 - pedwl 85 aJ 11809m 89b0i-ld\slenwddV Vnpvd epuod - V\LN9NVW89d Nl ewaUy\ uaI131:N EXHIBIT -014- PAGE -014 ELM 'ON VO 3d6d L6L6"6S9'£19 :'-N .uoyd (SOlOHS3aH1) SN0U33S SN0SIA38 m ,� A9 31Vo ON AA S8S££ ld 'o'lrl-A '0£Z •oB 'O'd /'/I -lNV-1 nSN00 ONI0'... ssoao n+oua3n :11l8V13SSV NO 1NVd Mr 09d LLOz 03 439 01 31VOdn NOLLVION l3NVd 03SS3038 Ll Ll L t .- vi N Y co' µ -I o }}}lll f�7jL; ONV '0 '0 ON Z ��1'i� 8DY£f 'oN 3'd NOOO SSV Hr lw Z l-4 1'10e0V30 OOV MON NOIld0 l3NVd N000 'A3H LI Sl Ol Bl BO Ol Z £ o of I nl ........... :iPlw40S d uopu.(1 3H391j nal-VWaH1 do 31W8 .48 P-o -d gwwnaop :13n008d �Bl/60/Ol 60664'oN� o L P I LU LU Z Z _ w � N D C N Q � C N N L X U � � C �+f OOn y 5 U N LY � U E� o W 0 n o` (V L a x a mp oaRx 0 cv� � o3a N O 5 O UE 0 Q OC LU v o o m N N Z �oL) d O E E E m� d O Z ° W p G° H Z y " 0 > OC in Ua ° a —0 V Q , v n Lie O a W � w O v V � n � U � y H ° n OOC e � � 0 ° ° n O ' ol e W 2 p� Z m N 9'L '6mP•gb'B9b02-ldUN3NtlfY1- (LT02J 89bOZ 1d4s6ulme�a - D\allsodwoo - pedw] SS Di 11 vagm agwz-ii\A-addv AnPc d ePWli - MlN3NHNtl3d m.L ewiaVL\slualp\:y EXHIBIT - 014 - PAGE - 015 I— £l86 '-N N-0 3deA SNOISV\321 46L8'699'£L9 :'-N —4d ee 489££ Z3 'o£Z •NI 'o'd /ICI ON180HONY 3WV8J ONV Nons 1 31V0 ON l I vi V) - , a m Nf OBd LIOZ 03 479 OL 3-VOdn Ll L! L -LNvwn r/siNvnn5No0 ONIO�Ine/'Oxj :AlBW3SSV ?JO 12JVd NOLLVION l3NVd 03SS30321 OMJ '0 '0 o Z 0 0 \ \`\1�� `\\��``�� �� ///' Q�v, .....,,. / eob£b -aN '3'd '3 8000 SSV7063813 Nf 1W ,Z L-S 11O80V30 OW 310N NOLLdO l3Nb'd N000 LL Sl O! Z $ cy opl �awoZy'•.,.�1 % MW40S uopw(l mj-L-VWa3H1 ` �paLyle +46 puoa.,d TWOONd 3 a o35 S8l/60/0l 60KV'ON ;• 1/nnu\0,EE Maul Caul oo m < p CC a o z `03 = e,_ V Oe6 r D C QQLLA I*dul •o•o 'XVW „4l I du)'o'o 'XVW „S'8t >14 Q U- CL O Ln f e 9 8'6MP'9-b'89402-13\1N3HNn] - (L182) 8900Z 14\56U!MN(I - :)\a4SWWO:) - JDWWJ SS 7311846M 89b6Z-!J\Sl2Awddv pnPdd QPPgj - V\-N3NVM3d nrl ew.a41\sauai0\ N EXHIBIT - 014 - PAGE - 016 na❑ � ina mn a ioz £L96 'ON 'V'O 3d93 SNOISIA38 46 L6'699'£LII �oN ouoyd nA A6 31V0 ON 96s££ ,d --PI-A '0£Z xo8 •0•d /L/L S�(bl�o 3adiiiaaiM /'U Nf D63 LLOZ 03 4a9 Ol 31VOdn LL Ll L L \,'1tlNp� ,nnsNoo ONI011nB wj ;Al9W3SSV a0 IbVd NOILVION 73NVd 03SS303a ONV F- J N rnl %,% �LI Hf 'O '0 Z l-S 11090V3a 00V LL S! 0l Z ImZ p 'oN '3'd aooa ssa»83atJ 1W 310N N0ud0 13NVd aoo0 •A3a 9L 80 OL £ p 9 o I \ .: 'VCRIOjy'•..: V'% aplwyos3 uopu.c-1 nal-VWa3l-fl = Q L ip 31a9 :AS p-.d-d nu.wnaoa uon00ad agv6orol MID 02 zi =i � N Y K m z m m = U m Uy0✓� x w0 O O s I +I ,sa t9 CL �,bt'94 „LE'Sd I o ® a ,°a O pp Spa y K w p Y 0 0 z > > w0 m m � gyqvr aooa aooa MOO'` o � d01W0adIOI'II OIa9AHlift OIa9AH/tn OIa9AH/111 N ('dul ,A'Sz Nj s'sz 9iNVf do MCI 8000 800(l c dO1W0ad,ZI'9 =9 )1009 N009 fdAD s'sz 1'dul s'sz Na) ssz z 'x a rr W p N C] N (S't C.99'09 0 „Zl � o d ® Y0 �O O� o Z� LH w Oy 2 �c� d 02- SpS�yO ti m S Q Y w O co (�,S' I �) .,BB'09 F O o H a S'S my -~•+ U QQV an c0 7 �u,h 0H ~O J 5 � � wpp Y � g W N ^ N N N O y O• O O O L m la = Y Y 0 F Q u u ••-� C9 2r CNV (`1 g X �; O N ep N mx Y C K Q X K O N X K O N z5:E C] O 9*6'6.p'9-0'99b0Z--W\1N3N6f1] - (ZIOZ) 69ooZ ld\sftt-0 - J\aa odwo3 - Pedwi SS 3J ll N09m 9960Z-1i\sle—ddV pnGwd epuold - V\ N3NVWd9d Ni euuayyNqua10\:y EXHIBIT - 014 - PAGE - 017 Oni v no❑ O me ma v:oz £06 'ON 'V'3 Ud U SN0ISIA38 L60'699'£LU :'ON au04d sioN0dW00 J.8I RV0 ON a ^I 969££ Nld '001APA 'O£Z XOB 'O'd M_ mr 09d LIOZ 03 419 Ol 31VOdf1 Ll Ll L l 01 Y t�i LO 'S1NVJlnSN03 ONIOline :Al8N3SSV NO 18tld NOLLVION 13NVd 03SS3338 ONV JvN// d 130 L xr '3 -0 Z L-9 110V30 OOV Ll 9l OL Z z z O of R7��1 LIB 60f£i 'ON '3'd 8000 SSVI`JN301-4 IN MON NOLLd0 l3NVd dOOa 'A3N Bl BD Ol £ O • ydWOjy., i i,1-40S 'd uOpuA-1 naL—vn83H1 (L d03LA08 :fa puedud 13ilO0bd ' 8l/60/Ol WKVV ,0 � x9L-0 T1 O O E O 'E zo to o •n O 3E a o89 = W y .Sl L — „LO L ---i S'L x101 L6'0 e�Su_ So- 0 � � o• q o O O - a h .=.i v E M Z U Z O m a 3 . z z � a zso•o SL .SS'L�i o s O"�' Ov OU O $ �a O Q z z m z m z SoS x m Q M SS l �-I xSEL —i xSSL �'I 6L' L SS, L 9'p[ '6mpq-b'B9b0Z-liWJ3NLN - (L[pZ) d9b0Z lj\s6ulmei0 - ]\a1LSOdwvD - P OWI SS Ol 11 U06M 99KZ-USIZAdddV PnPOW apuoy - VUH3NVWd3d [ul Owa4L\Rua10\:y EXHIBIT - 014 - PAGE - 018 £L98 •oN -CO 3d8J SNOISIA3 L6L6'65D'£L7 :'oN auoyd nq 565£f l.� 'ooNI-A '0£L ><oB 'O'd /'/I_^�yn S-Ma3-" 30 file 31VO ON .- Lij rn 1� 7 (0 ^I 479 Ol 3La0dn LL LL L l 03SS303N ONaN` ``„SLLI�7}i,S1Na1lnSN00 ONIOlins (Ll -y�(�L (Ll :A18VOSSa 80 iWd 11080a30 00a ftNOUVION LL 5l 0l Z '3'd a000 ssaloa3el� o I Nad 0000 'A3a BL SO OL £ VOIy'•. . ;PIw4o5 'd �eouRl /lal—VW83H1 do alvLo :/a P—d-d :Lan00ad 3 o 6 8!/60/0l / nnm o :.._ U W V} tl Eon �zm o\c<>J o\ o\�>J o\�>J n\<Jcc>g2W?3Z�JZ�J_ a\C<>J J1N NJLF \a �>J(22W[!2Z�M�W_L—V�'_—� \accC>J(2( \a�>J aU QaNY�JiCW'� gN2NWF3Z(�'_W—" gy2eL?3MJZnWNu`13J 2NNWIS3vZ���_— W!3✓�ZM—��� � vH 7 J Jz Jt 9'Tt '6mp9-b'B9LOZ-1jW1311NN - ((1 OZ) 8960Z 1i156uI—U - :)\aLpadwoo - DvdwL 55 ]f ll tl°6M 89MZ-IflAQ�dd11M0dd QPWH - V\1N3NVN19d Nl ewJaµL\s7uaIDV:U EXHIBIT - 014 - PAGE - 019 L IMES Evaluation Report ESR-4054 FBC Supplement Issued July 2017 This report is subject to renewal July 2018. www.icc-es.oru 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: SENTRY BUILDING INNOVATIONS 1209 ORANGE STREET WILMINGTON NEW CASTLE, DELAWARE 19801 www.roofnado.com EVALUATION SUBJECT: LAPLOCKTM PSU UNDERLAYMENT 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that LapLockT"' PSU Underlayment, recognized in ICC-ES master report ESR-4054, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code —Building ■ 2014 Florida Building Code —Residential 2.0 CONCLUSIONS The LapLockTM PSU Underlayment, described in Sections 2.0 through 7.0 of the master evaluation report ESR-4054, complies with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the International Building Code provisions noted in the master report. Use of the LapLockTM PSU Underlayment for compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential has not been evaluated, and is outside the scope of this evaluation report, For products falling under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, issued July 2017. !CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by /CC Evaluation Service, LLC, ecpress or implied, as to any finding or other matter in this report, or as to any product covered by the report. 4Z Qom `roman'iivr Copyright © 2017 ICC Evaluation Service, LLC. All rights reserved. Page 4 of 4 EXHIBIT - 014 - PAGE - 020 Collier County Payment Slip - Permits - Application November 12, 2024 A sufficiency review for permit application PRAC20241042897 has been completed. A payment slip has been generated and the outstanding balance is required to be paid in full within 14 calendar days as per Building Permit Fees — Resolution NO. 2021-193, section KK. Failure to make the payment in full within 14 calendar days, permit application PRAC20241042897 will be set to a "Denied" status and is considered closed. A new permit application covering the proposed construction shall be obtained before proceeding with the work. Contact: Kristen Jasinski 2805 Horseshoe Drive S, #10 Naples, FL 34104 Owner: BUOYANCY LLC Permit Location: 2225 23rd ST SW, Naples FEES: Description Application Number jPermit Number Fee Paid Fee Zoning Review - Application PRAC20241042897 PRAC2024104289701 $50.00 $0.00 Structural - Application Fee PRAC20241042897 PRAC2024104289701 $50.00 $0.00 Total: $100.00 $0.00 Total Owing: $100.00 Bonds: item T= I Balance Job Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples To pay online use the following link: https://cvportal.colliercountyfl.gov/cityviewweb Must be a GMD Public Portal registered user to make payment. EXHIBIT - 015 - PAGE - 001 Receipt Number: Transaction Number: Date Paid: Amount Due: Payment Details: Amount Paid: Change / Overage: Contact: FEE DETAILS: Fee Description Zoning Review - Application Structural - Application Fee Cashier Name: Batch Number: Entered By: Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT 20241261360 2024-103030 11/12/2024 $100.00 Payment Method Amount Paid Check Number Credit Card $100.00 3960318276 $100.00 $0.00 Kristen Jasinski 2805 Horseshoe Drive S, Suite 10 Naples, FL 34104 Reference Number Original Fee PRAC20241042897 $50.00 PRAC20241042897 $50.00 cvmanager 13566 RichardVazquez Amount GL Account Paid $50.00 131-138326-343990 $50.00 113-138900-322110-000000 EXHIBIT - 016 - PAGE - 001 COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DEPARTMENT / BUILDING REVIEW & INSPECTION DIVISION �- 2800 N. Horseshoe Drive, Naples FL 34104 * Phone (239) 252-2428 Outstanding Corrections Date: December 13, 2024 Contact Name: Kristen Jasinski Address: 2805 Horseshoe Drive S, #10 City, State Zip: Naples, FL 34104 Dear Applicant: PERMIT NO: PRAC2024104289701 APPLICATION NO: PRAC20241042897 JOB SITE ADDRESS: 2225 23rd ST SW, Naples Email:kristen@naplesfloridavacationhomes.com Plans submitted with the referenced permit have been reviewed. We are unable to approve your permit application for the reason(s) indicated below. For Applications Submitted through the GMD E-Permitting Portal: • Resubmittals must be submitted in the same session and the changes must be clouded. • Corrected documents must be submitted as complete files (with the corrected sheets replacing the rejected sheets). Submittals containing just the corrected sheets will be returned as Insufficient. • A written letter of response summarizing the changes made to address each correction comment must be included in your resubmittal. Failure to include a written letter of response will result in a rejection. • After your resubmittal is processed the documents will be reviewed again; additional deficiencies may be identified through this process. JOB DESCRIPTION: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples Rejected Review: Residential Review Reviewed By: Robert Moore Phone:239-252-5705 Email:Robert.Moore@colliercountyfl.gov Correction Comment 1: "As required by Florida Statute 553.842 and Florida Administrative Code 913-72, please provide a list of the Florida State Product Approval or Miami -Dade Notice of Acceptance for the building components. Please provide an index sheet listing all products being used including: 1. roof underlayment - missing product number. Rejected Review: FEMA Review Reviewed By: Johann Franco Phone:239-252-2694 Email:Johann.Franco@colliercountyfl.gov Correction Comment 1: BFE= AH-12.00 ft NAVD, 180 sgft Utility shed for equipment, Proposed FFE to Match existing house's FFE, however, House's FFE was not provided, structure should be proposed at BFE+ 1 foot (13.00 ft NAVD) OR otherwise Flood Vents will be required. Please proposed the FFE at 13 ft NAVD OR Please provide size, locations, calculations, Product Approval number and/or ICC approved model number for the Flood Vents to be Installed. Per FBC R322.2 & FEMA Technical Bulletin 1. FrancoJohann 12/12/2024 4:37 PM I,— FBC-R 8th 2023 R322.2.2 & Code of Laws & Ordinances Chapter 62 Floods Sec 62-75 & 62-80 - Enclosed area below design EXHIBIT -017- PAGE -001 flood elevation.- Enclosed areas, including crawl spaces, that are below the design flood elevation shall be used solely for parking of vehicles, building access or storage and be provided with flood openings if below base flood elevation. Please provide the proposed finished floor elevation of the shed. If proposed finished floor elevation of structure is below Base flood elevation (BFE) + 1 foot, then flood vents will be required. ATTENTION: Collier County Plan Review and Inspections routinely reviews all outstanding permit applications in order to determine their status. The review process includes appropriate responses from the permit applicant when the permit cannot be approved. When the applicant is advised of deficiencies and does not respond within 180 days with corrected plans or an appeal to the Code Enforcement Board, the permit application will become Void as per Collier County Ordinance 2002-01, Section, 104.5.1.1 to 104.5.1.4 (as amended). EXHIBIT - 017 - PAGE - 002 k4l JILDERS_j RE: Response to Correction Letter dated 12/13/24 Accessory Structure Permit Application, 2225 23rd Street SW PRAC20241042897 To Whom It May Concern, In response to your Outstanding Correction Letter dated 12/13/24, Residential Review, comment #1 - We have uploaded an updated NOA with includes the product number for the Sentry LapLock roof underlayment product. Furthermore, I have located a more comprehensive evaluation report (5 pgs vs. 1 pg) and am providing as a separate upload. FEMA Review, comment #1 - The existing house floor is at 13.0 NAVD as per the uploaded prior elevation certficate. Our application indicates that we will set the floor of the Accessory structure to match the house. Therefore, the new well house will have floor installed at 13.0 NAVD. Sincerely, Kristen Jasinski License # CRC1333281 2805 Horseshoe Drive S, #10, Naples, FL 34104 239-231-1166 EXHIBIT - 018 - PAGE - 001 ICC EVALUATION SERVICE'- IMES Evaluation Report ES R-4054 Reissued July 2024 Subject to renewal July 2025 This report also contains: CBC Supplement FBC Supplement ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation forits use. There is no warranty by ICC Evaluation Service, LLC, express orimplied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright ©2024 ICC Evaluation Service, LLC. All rights rese ved. DIVISION: 07 00 00— THERMAL AND MOISTURE PROTECTION Section: 07 30 05— Roofing Felt and Underlayment REPORT HOLDER SENTRY BUILDING INNOVATIONS LAPLOCKTM PSU AND ANCHORDECKTIM PSU UNDERLAYMENT 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: ■ 2021, 2018, 2015, 2012 and 2009 International Building Code° (IBC) ■ 2021, 2018, 2015, 2012, and 2009 International Residential Code° (IRC) Properties evaluated: ■ Physical properties ■ Water resistance ■ Ice barrier ❑❑ 1.2 Evaluation to the following green code(s) and/or standards: ■ 2022 California Green Building Standards Code (CALGreen), Title 24, Part 11 ■ 2020, 2015, 2012 and 2008 ICC 700 National Green Building Standard- (ICC 700-2020, ICC 700-2015, ICC 700-2012, and ICC 700-2008) Attributes verified: ■ See Section 3.0 2.0 USES 2.1 Roof Underlayment: The LapLockTM PSU and AnchorDeckTM PSU Underlayment is a self -adhering membrane that is used as an alternative to ASTM D226, Type I and Type II, roofing underlayment specified in IBC Chapter 15 and IRC Chapter 9. 2.2 Ice Barrier: The LapLockTM PSU and AnchorDeckTM PSU Underlayment is a self -adhering membrane that is used where an ice barrier is specified in IBC Chapter 15 and IRC Chapter 9. .1.0 DESCRIPTION 3.1 LapLockTM PSU LapLockTM PSU Underlayment is a multilayered self -adhering membrane composed of a synthetic top facer sheet and a polymer modified bitumen and a release rfilm on the bottom that is removed prior to attachment to plywood or oriented strand board (OSB) sheathing. The membrane is nominally 50 mils thick [0.050 inch (1.3 mm)], and is available in various sizes and colors. Standard roll size is 36 inches (914 mm) wide by 67 feet (20.7 m) long. Custom lengths and width are available. 71, YJAB Page 1 of 5 EXHIBIT - 018 - PAGE - 002 ES R-4054 Eon Page 2 of 5 Mast Widely Accepted and hosted 3.2 AnchorDeckTM PSU AnchorDeckTM PSU Underlayment is a multilayered self -adhering membrane composed of a synthetic top facer sheet and a polymer modified bitumen and a release rfilm on the bottom that is removed prior to attachment to plywood sheathing. The membrane is nominally 40 mils thick [0.040 inch (1.0 mm)] and is available in various sizes and colors. Standard roll size is 36 inches (914 mm) wide by 67 feet (20.7 m) long. Custom lengths and width are available. 3.3 Green Codes: The attributes of the LapLockTM PSU and AnchorDeckTM PSU Underlayment have been verified as conforming to the provisions of (i) CALGreen Section A4.407.5; (ii) ICC 700-2020 Sections 602.1.13, 11.602.1.13, 1202.9 and 13.104.1.7; (iii) ICC 700-2015 and ICC 700-2012 Sections 602.1.13, 11.602.1.13 and 12.5.602.1.14; and (iv) ICC 700-2008 Section 602.10 for ice barriers. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project -specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 4.0INSTALLATION 4.1 General: Installation of the underlayment must comply with this report and the report's published installation instructions. The report holder's published installation instructions must be available at the jobsite at all times during the installation. Prior to application of the membrane, the deck surface must be dry, free of frost, dust and dirt, loose fasteners, and other protrusions. Damaged sheathing must be replaced. Installation is limited to plywood and oriented strand board (OSB) substrates for LapLockTM PSU Underlayment. AnchorDeckT"^ PSU Underlayment is limited to plywood substrates. The membrane must be applied only when the ambient air and substrate temperatures are at or above 40°F (4.40C). The membrane is cut into 10- to 15-foot (3.05 to 4.57 m) lengths and rerolled. The release film is peeled back approximately 1 to 2 feet (0.3 to 0.6 m) and the membrane aligned with the lower edge of the roof and set in place with the printed side facing up. The remainder of the membrane is applied directly to the roof deck by removing the release film and firmly pressing the membrane in place. Alternatively, starting with a full roll of membrane, an approximately 3- to 6-foot (1-2 m) piece of membrane is unrolled while the release liner is left in place. The membrane must be aligned and rolled in the intended direction of membrane application. The release liner on the bottom of the roll is cut carefully in the cross direction without cutting of the membrane. Approximately 6 inches (152 mm) of the release liner in the opposite direction of the intended membrane application must be peeled back, exposing the adhesive. The roll is pulled along the roof deck, leaving the applied membrane on the deck. The membrane is pressed to the roof deck by applying hand pressure followed with a 40 lb (18.2 kg) or heavier pressure roller to smooth and secure the membrane including the overlaps that must be rolled firmly with a seam roller. Subsequent courses of membrane are applied parallel to the eave, from the lower edge of the roof upwards, in a shingle -lap manner. The vertical (end) seams must be overlapped a minimum of 6 inches (152 mm). Horizontal (side) seams must be overlapped a minimum of 3 inches (76 mm) and must run with the flow of water in a shingling effect. The membrane must be installed in sufficient courses to extend up the roof a minimum distance of 24 inches (610 mm) beyond the interior of the exterior wall. The underlayment in the field of the roof must overlap the membrane. If the membrane becomes misaligned, the roll must be cut and restarted. The membrane must be pressed firmly into place, from the center to edge. After application, the membrane must be inspected and any defects repaired. "Fish mouths" must be slit, pressed flat, and covered with a round patch of membrane of sufficient width and length to overlap each side and end of the slit a minimum of 6 inches (152 mm). Flashing around protrusions or metal drip edges must be over the membrane to prevent water backup. Installation of the roof covering can proceed immediately following application of the membrane. The membrane must be covered by an approved roof covering as soon as possible. For reroofing applications, the same procedures apply after removal of the old roof covering and roofing felts to expose the plywood roof deck. EXHIBIT - 018 - PAGE - 003 ESR-4054 Page 3 of 5 Most Widely Accepted and Trusted 4.2 Roof Underlayment: LapLockTM PSU and AnchorDeckTM PSU Underlayment must be installed as prescribed in IBC Chapter 15 or IRC Chapter 9 where an ASTM D226, Type I or Type II, underlayment is required. 4.3 Ice Barrier: When used as an ice barrier, the membrane must be installed as prescribed in IBC Chapter 15 and IRC Chapter 9 where an ice barrier is required. The membrane must be installed in sufficient courses to extend up the roof for a minimum distance of 24 inches (610 mm) inside the exterior wall line of the building. When used as roof underlayment in the field of the roof, the underlayment must overlap the ice barrier. 4.4 Flashing: Flashing must be in accordance with the applicable code. Flashing around protrusions must be over the lower course of the underlayment to prevent water backup. When used, metal drip edges must be installed beneath the underlayment at the eaves and over the underlayment at rakes. 5.0 CONDITIONS OF USE: The LapLockT"' PSU and AnchorDeckTM PSU Underlayment described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report and the report holder's published installation instructions. In the event of a conflict between the report holder's published installation instructions and this report, this report governs. 5.2 Installation of LapLockTM PSU Underlayment is limited to use on plywood and oriented strand board (OSB) substrates on structures located in areas where nonclassified roof coverings are permitted. 5.3 Installation of AnchorDeckTM PSU Underlayment is limited to use on plywood substrates on structures located in areas where nonclassified roof coverings are permitted. 5.4 Installation is limited to roofs having a slope of 2:12 (16.67 percent slope) or greater. 5.5 Installation is limited to use with roof coverings that do not utilize hot asphalt or coal -tar pitch. 5.6 Installation is limited to use with roof coverings that are mechanically fastened through the underlayment to the sheathing or rafters. 5.7 Installation is limited to roofs having attics or rafter spaces that are ventilated, in accordance with the requirements of the applicable code. 5.8 The underlayment and ice barrier must be installed only when the ambient air and substrate temperature are at or above 40°F (4.4°C). 5.9 The membrane is manufactured under a quality -control program with inspections by ICC Evaluation Service, LLC. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the [CC -ES Acceptance Criteria for Roof Underlayments (AC188), dated February 2012 (editorially revised June 2020). 6.2 Data in accordance with the ICC-ES Acceptance Criteria for Self -adhered Roof Underlayments for Use as Ice Barriers (AC48), dated February 2012 (editorially revised February 2021). 7.0IDENTIFICATION 7.1 The membrane is identified by a label on the packaging of each roll bearing the company name (Sentry Building Innovations), the product name (LapLockT"" PSU Underlayment and AnchorDeckT"4 PSU Underlayment), and the evaluation report number (ESR-4054). 7.2 The report holder's contact information is the following: SENTRY BUILDING INNOVATIONS 1209 ORANGE STREET WILMINGTON, DELAWARE 19801 www.roofnado.com EXHIBIT - 018 - PAGE - 004 ICC-ES Evaluation Report ESR-4054 CBC and CRC Supplement Reissued July 2024 This report is subject to renewal July 2025. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: SENTRY BUILDING INNOVATIONS EVALUATION SUBJECT: LAPLOCKM PSU AND ANCHORDECKTM PSU UNDERLAYMENT 1.0 REPORT PURPOSE AND SCOPE Purpose The purpose of this evaluation report supplement is to indicate that LapLockTM PSU and AnchorDeckT"' PSU Underlayment, described in IMES evaluation report ESR-4054, have also been evaluated for compliance with the code(s) noted below. Applicable code editions: ■ 2022 California Building Code (CBC) For evaluations of applicable Chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) AKA: California Department of Health Care Access and Information (HCAI) and the Division of State Architect (DSA) see Section 2.1.1 and 2.1.2 below. ■ 2022 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC: The LapLockTM PSU and AnchorDeckTM PSU Underlayment, described in Sections 2.0 through 7.0 of the evaluation report ESR-4054, comply with CBC Chapter 15, provided the design and installation are in accordance with the 2021 International Building Code® provisions noted in the evaluation report and the additional requirements of CBC Chapter 15, as applicable. 2.1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. 2.2 CRC: The LapLockTM PSU and AnchorDeckTM PSU Underlayment, described in Sections 2.0 through 7.0 of the evaluation report ESR-4054, comply with CRC Chapter 9, provided the design and installation are in accordance with the 2021 International Residential Code® (IRC) provisions noted in the evaluation report and the additional requirements of CRC Chapter 9, as applicable. This supplement expires concurrently with the evaluation report, reissued July 2024. WC -ES Evaluation Reports are not to be construed as representing aesthetics or anP other attributes not specifically addressed, nor are they to be cons'Irued v as an endorsement of the subject of the report or a recommendation Jw• its use. 17tere is no warranty by 1(-('Erahmtion Service, L L(: % express or implied( as �> to arc finding or other matter in this report, or as to amp product covered by the report. Copyright ® 2024 [CC Evaluation Service, LLC. All rights reserved. Page 4 of 5 EXHIBIT - 018 - PAGE - 005 ICC-ES Evaluation Report ESR-4054 FBC Supplement Reissued July 2024 This report is subject to renewal July 2025. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30 05—Roofing Felt and Underlayment REPORT HOLDER: SENTRY BUILDING INNOVATIONS EVALUATION SUBJECT: LAPLOCKTM PSU AND ANCHORDECKTM PSU UNDERLAYMENT 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that LapLockM PSU and AnchorDeckTM PSU Underlayment, described in ICC-ES evaluation report ESR-4054, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2020 Florida Building Code —Building ■ 2020 Florida Building Code —Residential 2.0 CONCLUSIONS The LapLockM PSU and AnchorDeckTM PSU Underlayment, described in Sections 2.0 through 7.0 of the master evaluation report ESR-4054, complies with the Florida Building Code —Building and the Florida Building Code —Residential. The design requirements shall be determined in accordance with the Florida Building Code —Building or the Florida Building Code — Residential, as applicable. The installation requirements noted in IMES evaluation report ESR-4054 for the 2018 International Building Code® and 2018 International Residential Code® meet the requirements of the Florida Building Code — Building or the Florida Building Code —Residential, as applicable. Use of the LapLockTM PSU and AnchorDeckTM PSU Underlayment for compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 61G20-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the evaluation report, reissued July 2024 K"C-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they, to be construed Q as an endorsentent of the .subject of the report or a recnnmtendation far its use. There is no ❑-arranty br ICC ' la'altlotion tierl'ice, LI.C, e.ypl'e.Ss or implied as i to any finding or other natter in this report, or as to any product covered by the report Copyright ® 2024 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 5 EXHIBIT - 018 - PAGE - 006 U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Buoyancy LLC A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 2225 23rd Street S.W. City State ZIP Code Naples Florida 34117 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) All of Tract 5 of Golden Gate Estates, Unit No. 195, Plat Book 7, Page 102, Collier County, Florida. A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. N 26°11'l9.4" Long. W 81°39'11.7" Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1A A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑ Yes Z No A9. For a building with an attached garage: a) Square footage of attached garage 1100 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes ❑X No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State COLLIER COUNTY 120067 COLLIER Florida B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood Zone(s) B9. Base Flood Elevation(s) Number Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 12021C 0410 H 05/16/2012 05/16/2012 AH 12.0' (N.A.V.D. 1988) B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 139: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 7 EXHIBIT - 018 - PAGE - 007 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: D 598 2004, ELEV=9.96' Vertical Datum: N.A.V.D. 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 13.0 ❑x feet ❑ meters b) Top of the next higher floor NSA. feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) NSA. ❑x feet ❑ meters d) Attached garage (top of slab) 11. 2 ❑x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 11 0 0 feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 10 8 ❑X feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 11 3 0 feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including NSA ❑X feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. / certify that the information on this Certificate represents my best efforts to interpret the data available. i understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑x Check here if attachments. Certifier's Name License Number David C. Holman 6279 David C. Holman, P.S.M., L.L.C. Title Professional Land Surveyor Company Name David C. Holman, P.S.M., L.L.C. Date: Address 8384 Laurel Lakes Boulevard City State ZIP Code P.S.M. No. 6279 Naples Florida 34119 Signature Date Telephone 05125/2017 (239) 289-6210 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) 1. The lowest elevation of machinery or equipment servicing the building is a concrete air conditioner pad at the right side of the residence, top of pad elevation = 10.94' (N.A.V.D. 1988). There is a concrete air conditioner pad at the left side of the residence, top of pad elevation = 11.39' (N.A.V.D. 1988). There is a concrete pool equipment pad at the left side of the residence, top of pad elevation = 11.39' (N.A.V.D. 1988). 2. Centerline of road elevation at the South property line extended = 10.70' (N.A.V.D. 1988). 3. Centerline of road elevation at the North property line extended = 10.31' (N.A.V.D. 1988). FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 7 EXHIBIT - 018 - PAGE - 008 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1, Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the communitys floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 7 EXHIBIT - 018 - PAGE - 009 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 7 EXHIBIT - 018 - PAGE - 010 BUILDING PHOTOGRAPHS OMB No. 1660-0008 ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, 'Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. r► 1�' J. { Y r E Photo One Photo One Caption FRONT VIEW (looking West) Photo taken 05/25/2017 i ' llf f;'tt�j�i�VJ�f� v�A Photo Two Photo Two Caption REAR VIEW (looking East) Photo taken 05/25/2017 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 7 EXHIBIT - 018 - PAGE - 011 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008 Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. 5 �F 4 u-. Photo Three Photo Three Caption LEFT SIDE VIEW (looking North) Photo taken 05/25/2017 F _ � Photo Four Photo Four Caption RIGHT SIDE VIEW (looking South) Photo taken 05/25/2017 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 7 EXHIBIT - 018 - PAGE - 012 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008 Continuation Page Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2225 23rd Street S.W. City State ZIP Code Company NAIC Number Naples Florida 34117 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. i 4,. - - 06 , Photo Five Photo Five Caption Air conditioner units (right side) Photo taken 05/03/2017 Air conditioner unit (left side) r'�µ1 A v Photo Six Photo Six Caption Pool equipment pad (left side) Photo taken 05/25/2017 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 7 of 7 EXHIBIT - 018 - PAGE - 013 ;�; erCouvity Address: 2225 23rd Street SW INDEX SHEET: Growth Management Community Development Department FL PRODUCT APPROVAL / MIAMI-DADE NOAS Include complete product number with decimal. Example: 20-0619.03 or 21563.2 Section A: DOORS # COMPONENT MANUFACTURER/MODEL IMPACT FL PA/NOA # Exp. Date Design Pressure 1 Swinging Therma Tru Fiberglass Door FL-20468.12 + 2 Sliding + 3 Garage + 4 + 5 + 6 + 7 + 8 + Section B: WINDOWS # COMPONENT MANUFACTURER/MODEL IMPACT FL PA/NOA# Exp. Date Design Pressure 1 Single/Dbl Hung + 2 Fixed 3 Casement PGT Casement Window 23-0817.12 04/11/2028 + 4 Horizontal Slider + 5 Mullion + 6 Skylights + 7 + 8 + 9 + 10 + Section C: ROOFING PRODUCTS # COMPONENT MANUFACTURER/MODEL FL PA/NOA # Exp. Date Design Pressure 1 Asphalt Shingles + 2 Metal + 3 Tile Santa Fe Clay Tile 21-0614.05 2/1/26 + 4 Single Ply + 5 Underlayment Sentry LapLock ESR-4054 July 2025 + 6 Vents + 7 + - 8 + Section D: STORM SHUTTERS # COMPONENT MANUFACTURER/MODEL FL PA/NOA# Exp. Date Design Pressure 1 +- 2 + 3 + Section E: PANEL WALLS # COMPONENT MANUFACTURER/MODEL FL PA/NOA# Exp. Date Design Pressure 1 Soffits + 2 Storefront + 3 + 4 1 - ~" PRODUCT APPROVALS/NOAs MUST BE ONSITE AT TIME OF INSPECTION Building Plan Review Inspection Division • 2800 North Horseshoe Drive - Naples, FL 34104 - 239-252-2400 FL Product Approval NOA Index Sheet - 1-1-24 www.colliercountyfl.gov/ Page 1 of 1 EXHIBIT - 018 - PAGE - 014 pgpJp� Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Accessory Structure at 2225 23rd Street SW - Permit No. PRAC20241042897 11-r message Robert Moore<Robert. Moore@coll iercountyfl. gov> Wed, Jan 8, 2025 at 1:40 PM To: Kristen Jasinski <kristen@jasinskibuilders.com> The permit is in under review status. Plans can not be upload until the permit is issued. Robert Moore Site Plans Reviewer II Building Plan Review & Inspection Office:239-252-5705 Robert.Moore@colliercountyfl.gov How are we doing? Please Click here to fill out a Customer Survey. We appreciate your Feedback! From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Wednesday, January 8, 2025 2:31 AM To: Robert Moore <Robert. M oore@coll iercou ntyfl. g ov> I ubject: Accessory Structure at 2225 23rd Street SW - Permit No. PRAC20241042897 Collier Counter ® oom EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Robert, I have been trying to upload the truss drawings for accessory structure to the portal to no avail. They are attached. Can you upload them or adjust the portal to allow me to upload them please? Thanks for your help. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 7�54• &k ILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com EXHIBIT - 019 - PAGE - 001 Collier County Customer Payment Slip - Permits Date: Contact: Owner: BUOYANCY LLC January 14, 2025 Kristen Jasinski 2805 Horseshoe Drive S, #10 Naples, FL 34104 Permit Location: 2225 23rd ST SW, Naples Job Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples FEES: Descri lion_ 1,8pplication Number Permit Number Fee I Paid Fee Inspection Fee PRAC20241042897 PRAC2024104289701 $650.00 $0.00 Site Engineering PRAC20241042897 PRAC2024104289701 $150.00 $0.00 Structural - Review Fee PRAC20241042897 PRAC2024104289701 $50.00 $0.00 FEMA - Review Fee PRAC20241042897 PRAC2024104289701 $100.00 $0.00 BCAI PRAC20241042897 PRAC2024104289701 $12.75 $0.00 DBPR Surcharge PRAC20241042897 PRAC2024104289701 $8.50 $0.00 Total: $971.25 $0.00 Bonds: Total Owing: $971.25 The following conditions must be satisfied before your permit can be issued: The following conditions must be satisfied before you can call your first inspect Permit is on inspection hold until the following deferred items are submitted as a revision: truss la Sub Contractor (Roofing) Upload to the condition on portal. You can track your permit using the following link: https://cvportal.col I iercou ntyfl. gov/C ityViewWeb//Permit/StatusReference?referenceN umber=P RAC20241042897 EXHIBIT - 020 - PAGE - 001 The impact fee calculation and/or deposit sheet can be found at the following link: https://cvportal.colliercountyfl.gov/CityViewWeb/ To pay online use the following link: http-s://cvportaI.colliercoun yfl ciov/cityviewweb Must be a GMD Public Portal registered user to make payment. EXHIBIT - 020 - PAGE - 002 On Fri, Jan 31, 2025 at 12:49 PM Robert Moore<Robert.Moore@colliercountyfl.gov> wrote: Good afternoon Kristen, Next week we are available Monday at 1:00, Tuesday and Wednesday at 11:00 Robert Moore Site Plans Reviewer II Building Plan Review & Inspection Office:239-252-5705 Collier County Robert. Moore@colliercountyfl.gov a ffloom How are we doing? Please Click here to fill out a Customer Survey. We appreciate your Feedback! From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Friday, January 31, 2025 9:37 AM To: Robert Moore <Robert.Moore@ coil iercountyfl.gov>; Toby Hartwell <Toby. Hartwell @colliercountyfl.gov>; Toby Hartwell <Toby. Hartwell @colliercountyfl.gov> Cc: Thomas Messer <Thomas.Messer@ col lierco untyfl.gov>; Derek Cronin<dcronin@croninengineering.com>; Joe Proctor <jproctor@croninengineering.com> Subject: Re: Permit Application PRFH2O24104123201 - 2225 23rd Street SW EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. I- Gentlemen, I am following up with an additional request to meet with respect to the After -the -Fact permit application for 2225 23rd Street SW. In your corrections letter dated November 20th, it was indicated that the scope of work was unclear. Sheet A-4.1 provides a detailed scope of work as it pertains to comments on SheetA-4. We are please that the permit for new accessory structure to house the well house and water treatment equipment has been approved. However, we cannot proceed with building it without having electricity. Electrical work is incorporated together with the plans for the main house and overall property. We are eager to satisfy the County's requirements and will greatly appreciate a meeting or phone call to help us better understand how the scope of work is unclear or how the plans should be revised. I look forward to hearing from you soon. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 BUILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 Cell: 847-902-9133 EXHIBIT - 021 - PAGE - 001 Verbal communications from Client to Architect, Brian Palkovic, about meeting on 02/05/2025 to get clarity on scope of work for plans EXHIBIT - 022 - PAGE - 001 PRAC2024104289701 COLLIER COUNTY �... BOARD OF COUNTY COMMISSIONERS PERMIT PERMIT #: PRAC2024104289701 PERMIT TYPE: Building DATE ISSUED: March 17, 2025 BUILDING CODE IN EFFECT: FBC 8th Edition 2023 w/ 2024 sup] JOB ADDRESS: 2225 23rd ST SW, Naples FOLI #: JOB DESCRIPTION: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples OWNER INFORMATION: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 AREA OF WORK (SQFT): 180 SETBACKS: FRONT: 75' REAR: 75' LEFT: 30' RIGHT: 30' FLOOD ZONE: AH SEWER: Septic WATER: Existing CONTRACTOR INFORMATION: CERTIFICATE #: JASINSKI BUILDERS, LLC LCC20220001360 2805 HORESHOE DRIVE S, #10 NAPLES, FL 34104 (239)231-1166 EXHIBIT - 023 - PAGE - 001 INSPECTION JOB CARD To schedule inspections call 239-252-3726 or visit https://cvportal.coiliercountyfl.gov/cityviewweb PR-AC2024104289701 SETBACKS: FRONT: 75' REAR: 75' LEFT: 30' RIGHT: 30' SPECIAL: FLOOD FZAH ZONE: INSPECTION OUTCOME COMMENTS 107 - Truss/Sheathing/Bucks 108- Framing All rough trade inspections must be passed prior to scheduling. 111- Dry-in/Flashing 115 - Building Final 118 - Lintel Beam 119 - Fill Cells 133 - Monolithic Slab 134 - Roofing Final 136 - Impact Glass 154 - Soffit Coverings In Please do NOT complete Soffit installation prior to inspection. progress 801 - Site Drainage 802 - Landscaping 810 - Exotic Vegetation Removal 814 - Erosion/Silt The 814 - Erosion/Silt must be passed before any other inspections are scheduled. OPEN CONDITIONS Condition Type: Condition Description: NOTICE OF CLEARING RESTRICTIONS: The issuance of a building permit for a single-family dwelling allows up to Informational one (1) acre of native vegetation to be cleared. Clearing more than one (1) acre may be allowed for accessory structures and requires a separate Vegetation Removal Permit. Properties located in the following zoning district overlays may not be allowed to clear one (1) acre: Rural Fringe Mixed Use District (RFMU), Big Cypress Area of Concern (ACSC), and Special Treatment Overlay (ST). There may be additional restrictions related to clearing native vegetation and impacts to wetlands or protected species found on the property. State and Federal agency permits may be required. Contact the Growth Management Department?s Environmental Services at (239) 252-2400 for additional information. Informational Use the form located at https://www.colliercountyfl.gov/home/showdocument?id=105797&t=638403984984558370 to request Permit extensions, cancellations, and changes/withdrawals of Contractors, Subcontractors and Qualifiers. Instructions are provided with the form. Right -of -Way (ROW) and Well permits may only use this process for cancellations. Change/withdrawal of contractor does not apply to self -issued permits. Contact Building Permit EXHIBIT - 023 - PAGE - 002 PRAC2024104289701 Resolution Services at 239-252-2493 for assistance completing the form. Submit the form by clicking the Browse button below. Informational FEMA - All equipment must be above flood plus one foot. Any materials used below flood level must comply with FEMA regulations Informational A Survey is required and must verify that improvement(s) meet setbacks, easements, and elevation requirements per Chapter 62, Collier County Code of Laws and Ordinances. Throughout the duration of the permit, please review the survey conditions for when to upload the survey. CO Hold Soil Compaction Test. Upload to the condition on the portal. Inspection Hold Permit is on inspection hold until the following deferred items are submitted as a revision: truss layout. CO Hold BFE= AH-12.00 ft NAVD, 180 sgft Utility shed for equipment, Proposed FFE to Match existing house's FFE _ 13.00 ft NAVD per House's EC submitted and plans. FrancoJohann 01/13/2025 4:58 PM Inspection Hold Sub Contractor (Roofing) Upload to the condition on portal. NOTE: If you are unable to schedule your inspection, please contact the inspection desk at 252-2400. NOISE ORDINANCE: Collier County Codes of Laws and Ordinances 54-92(f) Construction Sound. NOISE LIMITATIONS are in effect at all times. Work permitted, RESIDENTIAL Areas — 6:30 AM to 7:00 PM Monday thru Saturday; NON-RESIDENTIAL Areas (more than 500 feet from Residential Area) 6:OOAM to 8:OOPM Monday thru Saturday. No Work on Sundays or Holidays. RADIOS, LOUDSPEAKERS, ETC. — Must not disturb peace, quiet and comfort of neighboring inhabitants. FREE CABLE LOCATIONS — Call 48 Hours prior to digging/FPL 434-1222/UTS 1-800-542-0088/PalmerCATV 783-0638 and all other applicable utilities. Per currently adopted building code ordinance, as it may be amended, all work must comply with all applicable laws, codes, ordinances, and any additional stipulations or conditions of this permit. This permit expires if work authorized by the permit is not commenced within six (6) months from the date of issuance of the permit. Additional fees for failing to obtain permits prior to the commencement of construction may be imposed. Permittee(s) further understands that any contractor that may be employed must be a licensed contractor and that the structure must not be used or occupied until a Certificate of Occupancy is issued. NOTICE: PRIOR TO THE REMOVAL OF ASBESTOS PRODUCTS OR THE DEMOLITION OF A STRUCTURE, FEDERAL AND STATE LAWS REQUIRE THE PERMITTEE (EITHER THE OWNER OR CONTRACTOR) TO SUBMIT A NOTICE OF THE INTENDED WORK TO THE STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP). FOR MORE INFORMATION, CONTACT DEP AT (239) 344-5600. NOTICE: In addition to the conditions of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. EXHIBIT - 023 - PAGE - 003 Approval of Construction Documents Building Plan Review & Inspection unty 2800 N. Horseshoe Dr, Naples, FL 34104 239-252-2400 Build It! REVIEWED FOR CODE Residential Permits COMPLIANCE These electronic documents have been reviewed for Code Compliance by the Building Plan Review & Inspection Division of the Collier County Growth Management Department. The documents are available for download from the GMD Public Portal. These specific documents, listed as "Approved Plans (PR)" on the Portal, must be available for Inspectors to review on the job site in either electronic or paper form as the approved version in accordance with the Florida Building Code Section 107.3.1. Other supporting documents may be required on site as needed to meet code requirements. Permit Number: PRAC2024104289701 Job Site Address: 2225 23rd ST SW, Naples Permit Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. 2225 23rd ST SW, Naples Permit Issuance Date: 0311712025 Document List: Portal File Type Portal File Name 1. Approved Plans (PR) Construction Plans (2225 23rd St - 11-7-24 - WELL HOUSE_ESEAL - Prepared (Received).pdf) 2. Approved Plans (PR) Construction Plans (4970_03_02 2225 23RD ST_ SW_ Well House 09-27- 24_ESEAL (1) - Prepared (Received).pdf) 3. Approved Plans (PR) Site Planning Document (2225 23rd Street SW Survey for Permit application 101324 - Update Boundary Survey (1) (Received).pdf) 4. Approved Plans (PR) Storm Water Plan (Stormwater Plan Worksheet (Received).pdf) 5. Approved Plans (PR) Specialty Engineering and Specification Sheets (Truss Deferral Letter 110624 - Prepared (Received).pdf) 6. Approved Plans (PR) Construction Plans (4970.03.02 2225 23RD ST. SW._12-17-24_ESEAL - Prepared.pdf) 7. Approved Plans (PR) Product Index Sheet (NOA Index Sheet Updated for 2225 23rd Accessory Structure - Prepared.pdf) EXHIBIT - 023 - PAGE - 004 Approval of Construction Documents Building Plan Review & Inspection 2800 N. Horseshoe Dr, Naples, FL 34104 239-252-2400 Residential Permits co*er S o ty Build It! REVIEWED FOR CODE COMPLIANCE 8. Approved Plans (PR) NOA Index Sheet Updated for 2225 23rd Accessory Structure - Prepared.pdf EXHIBIT - 023 - PAGE - 005 Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT Receipt Number: 20251299085 Transaction Number: 2025-024022 Date Paid: 03/17/2025 Amount Due: $971.25 Payment Details: Payment Method Amount Paid Check Number Credit Card $971.25 4177893696 Amount Paid: $971.25 Change / Overage: $0.00 Contact: Kristen Jasinski 2805 Horseshoe Dr S Naples, FL 34104 FEE DETAILS: Fee Description Reference Number Original Amount GL Account Fee Paid Inspection Fee PRAC20241042897 $650.00 $650.00 113-138900-322110-000000 Site Engineering PRAC20241042897 $150.00 $150.00 131-138327-322490 Structural - Review Fee PRAC20241042897 $50.00 $50.00 113-138900-322110-000000 1.- FEMA - Review Fee PRAC20241042897 $100.00 $100.00 113-138900-322110-000000 BCAI PRAC20241042897 $12.75 $12.75 113-000000-208820 DBPR Surcharge PRAC20241042897 $8.50 $8.50 113-000000-208800 Cashier Name: cvmanager Batch Number: 13880 Entered By: Anna.Gonzalez EXHIBIT - 024 - PAGE - 001 TtH RT , " Kristen Jasinski <kristen@naplesfloridavacationhomes.com> ass Plans for PRAC20241042897 Accessory Structure - 2225 23rd Street SW '—rmessage Kristen Jasinski <kristen@jasinskibuilders.com> Wed, Jul 2, 2025 at 10:18 PM To: Robert Moore <Robert.Moore@colliercountyfl.gov>, richard.vasquez@colliercountyfl.gov Richard / Robert, Attached please find the truss plans for the accessory structure to house well and water treatment equipment at 2225 23rd Street SW. Unfortunately, there is no place to upload these documents in the portal. I spent quite a bit of time on the phone with a young lady in your customer service department but we were unsuccessful. Can I ask you or someone from your team to upload for review please? Please see the attached. Also, I have closely reviewed the required inspections and conditions and will appreciate you hearing my concerns as follows: 1. 814 Erosion / Silt Inspection - is this really necessary? We are putting about 18-24" of compacted fill with approximate size of 20' x 22'. This relatively small mound of dirt is on a 3 acre parcel. This mound of dirt is over 80' from the neighbors property. 2. 810 Exotic Vegetation Removal - when should this inspection be called? We are removing no vegetation as a result of this work. I believe there was something in our application affirming that no vegetation would be removed in the course of building this accessory structure. 3. 801 Site Drainage - scope of work does not call for any changes or modification to drainage on site. Again, as described in #1 above - this relatively small raised pad is very any neighboring property line. 4. Sub -contractor Roofing -As a FL licensed Residential Building Contractor, I have been allowed to replace several roofs on various projects. I would appreciate it if we can do our own roof on this small accessory structure. Thank you for your assistance with the above. Happy 4th of July. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 EGG SK�i �BZJILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com 3 attachments .� 3242506 - Jasinski Builders - Well House - 2225 23rd St SW - Truss Placement Plan.pdf 112K 3242506 - Jasinski Builders - Well House - 2225 23rd St SW - Preliminary Truss Designs.pdf 501 K Truss Submittal Letter 070225.pdf 115K EXHIBIT - 025 - PAGE - 001 BJILDERS July 2, 2025 Mr. Richard Vazquez & Mr. Robert Moore Collier County Building Department Via email: Rich ard.Vazquez(a.colIiercountyfl.aov / Robert.Moore@colliercountyfl.gov TEL: 239-252-2576 RE: Truss Submittal Letter 2225 23rd Street SW PRAC20241042897 - Application for new Accessory Structure (well house) To Whom It May Concern, This letter accompanies the submittal of truss drawings for the accessory structure at 2225 23rd Street SW. Please review at your earliest convenience. Please proceed with the plan review related to our application for building a new accessory structure at 2225 23rd Street SW. Sincerely, Kristen Jasinski License # CRC1333281 2805 Horseshoe Drive S, #10, Naples, FL 34104 239-231-1166 EXHIBIT - 026 - PAGE - 001 Job Truss Truss Type City ply 3242506 Revised 1A Common 2 1 Job Reference (optional) Tibbetts Lumber Co. LLC. Lehioh Acres. FI. 33971. aok-n—k 2-0-0 a u-u-u - ....._ _.. - - - 1. s ue 1e1i ur w:oo:oc rage: 1 ID:Eb0MoFkl9D09jR2Mjgq NOizxk1 D-3Wrc4BCLAboFPfSAZhwrCW4jC913kgpgjPc5duz jus 4X4 3 12-0-0 14-0-( 6-0-0 2-0-0 5 b_U-U 12-0-0 6-0-0 6-0-0 Scale = 1:32.1 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) -0.03 6-12 >999 360 MT20 244/190 TCDL 20.0 Lumber DOL 1.25 BC 0.61 Vert(CT) -0.08 6-12 >999 240 BCLL 0.0* Rep Stress Incr YES WB 0.07 Horz(CT) 0.01 4 n/a n/a BCDL %0 Code FBC2023/TP12014 Matrix -MP Wind(LL) 0.07 6-12 >999 240 Weight: 51 lb FT = 20 LUMBER BRACING TOP CHORD 2x4 SP N0.2 TOP CHORD Structural wood sheathing directly applied or 4-9-12 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Ri id ceilinq directiv applied or 10-0-0 oc bracing. WEBS 2x4 SP No.2 MiTek recommends that Stabilizers and required cross bracing be REACTIONS (lb/size) 2=760/0-8-0, (min. 0-1-6), 4=760/0-8-0, (min. 0-1-8) installed during truss erection, in accordance with Stabilizer Max Horiz 2=-182 (LC 10) Installation guide. Max Uplift 2=-350 (LC 12). 4=-350 (LC 12) FORCES (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-759/354,13-14=-748/356, 3-14=-695/375, 3-15=-695/375, 15-16=-748/356, 4-16=-759/354 BOT CHORD 2-6=-27/541, 4-6=-27/541 WEBS 3-6=-11/305 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-22; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=oft; Cat. ll; Exp C; Enclosed; MWFRS (directional) and C-C 10-2-15 to 14-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 350 lb uplift at joint 2 and 350 lb uplift at joint 4. LOAD CASE(S) Standard EXHIBIT - 026 - PAGE - 002 Job Truss Truss Type City ply 3242506 Revised 1 B Hip 2 1 Job Reference (optional) Tibbetts Lumber Co. LLC. Lehiah Acres. Ft. 33971 wnk—r;vk 2-0-0 mc. I ue don u, l4tbb'a3 Page: 1 0:aYpErycu_l1 RpCwJWOOZjlzxkl8-OvzMVsEbiC2yezbZg6zJHx95uy25ClrzAj5Cinzxjuq 5-0-0 7-0-0 12-0-( 5-0-0 2-0-0 5-0-0 5x5 5x5 3 4 2-0-0 4-10-4 7-1-12 12-0-0 4-10-4 2-3-8 4-10-4 Scale = 1:32.1 Plate Offsets (X. Y): [3:0-2-8,0-2-1], [4:0-2-8,0-2-1] Loading (psf) Spacing 2-0-0 CS] DEFL in (loc) I/defi L/d PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.02 8-11 >999 360 MT20 244/190 TCDL 20.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.05 8-11 >999 240 BCLL 0.0` Rep Stress Incr YES WB 0.03 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2023ITP12014 Matrix -MP Wind(LL) 0.03 7-14 >999 240 Weight: 58 lb FT = 20% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceilinq directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.2 MiTek recommends that Stabilizers and required cross bracing be REACTIONS (lb/size) 2=760/0-8-0, (min. 0-1-8), 5=760/0-8-0. (min. 0-1-8) installed during truss erection, in accordance with Stabilizer Max Horiz 2=-160 (LC 10) Installation guide. Max Uplift 2=-350 (LC 12), 5=350 (LC 12) FORCES (Ib) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-746/346, 3-15=-665/361, 3-4=-610/406, 4-16=-666/367, 5-16=-746/352 BOT CHORD 2-8=-51/593, 7-8=-54/588, 5-7=-99/563 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-22; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=4ft; Cat. 11; Exp C; Enclosed; MWFRS (directional) and C-C 11-6-7 to 14-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 350 lb uplift at joint 2 and 350 lb uplift at joint 5. LOAD CASE(S) Standard EXHIBIT - 026 - PAGE - 003 Job Truss Truss Type Qty Ply 3242506 Revised 1 ru Hip Girder 2 1 Job Reference (optional) V aAcrcs, H.339 4..p,�yk 2-0-0 nun: 8.72 S Nov 27 2023 Print: 8.720 S Nov 27 2023 MTek Industries, Inc. Tue Jan 07 14:55:53 Page: 1 I D:uFN09QvbJOcOsLz?vi47S9zxk?i-OvzMVsEbiC2yezbZg6zJHx97ry10CkDzAj5Cinzxjuq 3-0-0 1 3-0-0 5x5 3x4 3-0-0 5x5 1r 73 16 4 17 5 3-0-0 1 2-0-0 T2 1'_412 Ivi N 1 1 � �— 2 6 0-4-g l B1 —''.— t ° 9 18 19 8 t t t t t 1 3x4 3x4 3x4 3xa 2-10-4 Scale = 1:32 Plate Offsets (X, Y): [3:0-2-8,0-2-1],[5:0-2-8,0-2-1] rr-u 6-3-8 Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) I/deft Ud TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.40 Vert(LL) -0.05 8-9 >999 360 TCDL 20.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.10 8-9 >999 240 3CLL 0.0' Rep Stress Incr NO WB 0.07 Horz(CT) 0.02 6 n/a nla BCDL 10.0 Code FBC20231TPI2014 Matrix -MP Wind(LL) -0.05 8-9 >999 240 LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING TOP CHORD BOTCHORD REACTIONS (lb/size) 2=711/0-8-0, (min. 0-1-8), 6=711/0-8-0, (min. 0-1-8) Max Horiz 2=-114 (LC 6) Max Uplift 2=-428 (LC 8), 6=-428 (LC 8) Max Grav 2=932 (LC 13), 6=932 (LC 14) FORCES (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1214/333, 3-16=-958/304, 4-16=-958/304, 4-17=-958/304, 5-17=-958/304, 5-8=-1214/333 BOT CHORD 2-9=-216/1042, 9-18=341/1256, 18-19=-341/1256, 8-19=341/1256, 6-8=-204/1042 WEBS 3-9=-521357, 4-9=-3071197, 4-8=-3071197, 5-8=-52/356 2-10-4 PLATES GRIP MT20 244/190 Weight: 59 lb FT = 20% Structural wood sheathing directly applied or 5-4-1 oc purlins Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-22; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=4ft; Cat. II; Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 428 lb uplift at joint 2 and 428 lb uplift at joint 6. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 287 lb down and 111 lb up at 3-0-0, 114 lb down and 34 ib up at 5-0-12, and 114 lb down and 34 Ito up at 6-11-4, and 287 Ito down and 111 lb up at 9-0-0 on top chord, and 168 Ito down and 98 lb up at 3-0-0, 36 lb down and 3 lb up at 5-0-12, and 36 lb down and 3 Ito up at 6-11-4, and 168 lb down and 98 lb up at 8-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (lb/ft) Vert: 1-3=-80, 3-5=-80, 5-7=80, 10-13=-20 Concentrated Loads (lb) Vert: 9=46 (F), 8=46 (F), 18=3 (F), 19=3 (F) EXHIBIT - 026 - PAGE - 004 Job Truss Truss Type Qty ply 3242506 Revised E3 Jack -Open 8 1 Tibbetts Lumber Ca. I I 1 ehinh A-- P1 aao7> >w.,. k ... .. __ .. Job Reference (optional) Nov Print: r , nun. 8.72 5 N27 2023 Print: d.72u 5 Nov 27 2023 MiTek Industries, Inc. Tue Jan 07 14:55:53 Page: 1 I D: W7MjZCC9Wh rORg h u8b23EQzxkl v-OvzMVsEbiC2yezbZg6zJHx92Zy5bCINzAj5Cinzxj uq -2-0-0 3-0-0 2-0-0 3-0-0 12 7 r" Q-4'�5:Z�: 3-0-0 Scale = 1:19.8 Plate Offsets (X, Y): [2:0-4-5,0-0-8] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) I/deb Ud PLATES GRIP TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) 0.00 4-7 >999 360 MT20 244/190 TCDL 20.0 Lumber DOL 1.25 BC 0.15 Vert(CT) 0.00 4-7 >999 240 BCLL 0.0' Rep Stress Incr YES WB 0.00 Horz(CT) 0,00 2 n/a nla �,.. BCDL 10.0 Code FBC20231TPI2014 Matrix -MP Wind(LL) -0.01 4-7 >999 240 Weight: 13lb FT=20% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS (lb/size) 2=361/0-8-0, (min. 0-1-8), 3=75/ Mechanical, (min. 0-1-8). 4=17/ Mechanical, (min. 0-1-8) Max Horiz 2=188 (LC 12) Max Uplift 2=-237 (LC 12). 3=-42 (LC 12) Max Grav 2=361 (LC 1), 3=87 (LC 17), 4=46 (LC 3) FORCES (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-511/183 BOT CHORD 2-4=-152/42B BRACING TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. NOTES 1) Wind: ASCE 7-22, Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=3ft; Cat. II; Exp C; Enclosed; MWFRS (directional) and C-C zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 3 and 237 lb uplift at joint 2. LOAD CASE(S) Standard EXHIBIT - 026 - PAGE - 005 Job Truss Truss Type Oty ply 3242506 Revised H3 Diagonal Hip Girder 4 1 Job Reference (optional) Tibbetts Lumber Co. LLC, Lehigh Acres. Ft. 33971, anka—vk..,...., ..... _ ___ _ Nov 3 Print. 8.l20 s N2r 2023 MiTek Industries, Inc. Tue Jan 07 14:55:54 Page: 1 ID:euA3sTZzSvdB1 Hzfuua5Slzxkl R-U5xkiCFDTWApG7AIEgUyp9iCzMJixCc6PNgIEDzxjup -2-9-15 4-2-3 2-9-15 4-2-3 Scale = 1:19.7 Loading (psf) Spacing 2-0-0 CSI TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.83 TCDL 20.0 Lumber DOL 1.25 BC 0.67 BCLL 0.0' Rep Stress Incr NO WB 0.DO 3CDL 10.0 Code FBC2023fTPI2014 Matrix -MP L� LUMBER TOP CHORD 2x4 SP N0.2 BOT CHORD 2x4 SP No.2 REACTIONS (lb/size) 2=31910-11-5, (min. 0-1-8), 3=53/ Mechanical, (min. 0-1-8), 4=-28/ Mechanical, (min. 0-1-8) Max Horiz 2=187 (LC 8) Max Uplift 2=453 (LC 8), 3=-72 (LC 5). 4=-71 (LC 19) Max Grav 2=497 (LC 13), 3=111 (LC 13), 4=133 (LC 25) 12 4.9497 r 4-2-3 DEFL in (loc) Well Ud PLATES Vert(LL) -0.11 4-7 >445 240 MT20 Vert(CT) 0.08 4-7 >613 240 Horz(CT) 0.00 2 n/a n/a GRIP 244/190 d N Weight: 18 lb FT = 20% BRACING TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins. BOT CHORD Ri id ceilinq directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. FORCES (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-8=-569/463 BOT CHORD 2-9=-460/521 NOTES 1) Wind:ASCE 7-22; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=Oft; Cat. II; Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 72 lb uplift at joint 3, 453 It, uplift at joint 2 and 71 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 148 lb down and 162 lb up at 1-5-4, and 148 lb down and 162 lb up at 1-5-4 on top chord, and 110 lb down and 113 lb up at 1-5-4, and 110 lb down and 113 lb up at 1-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (lb/ft) Vert: 1-3=-80, 4-5=-20 Concentrated Loads (lb) Vert: 8=159 (F=80, 8=80), 9=134 (F=67, B=67) EXHIBIT - 026 - PAGE - 006 Job Truss Truss Type Oty Ply 3242506 Revised J1 Jack -Open 8 1 Tibbetts Lumber Co. LLC, Lehigh Acres, FI. 33971, ankasorzvk Job Reference (optional) -7 rage: 1 ID:aTXaizE7sS5flkFX6CcyPzxk2C-USXkiC FDTWApG7AIEgUYp9iDJMRVxCc6PNqIEDzxjup -2-0-0 0-10-15 2-0-0 0-10-15 12 7r- 3 2 1 1 s 6 4 Alx4 0 0 Scale = 1:22.9 Plate Offsets (X. Y): [2:Edge,0-0-4] Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) I/deft L/d TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.74 Vert(LL) 0.00 7 >999 360 TCDL 20.0 Lumber DOL 1.25 BC 0.18 Vert(CT) 0.00 7 >999 240 3CLL 0.0' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2023(TPI2014 Matrix -MP Wind(LL) 0.00 7 >999 240 PLATES GRIP MT20 244/190 Weight: 7 lb FT = 20% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-10-15 oc purlins. SOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceilinq directly applied or 10-0-0 oc bracing. REACTIONS (lb/size) 2=383/0-8-0, (min. 0-1-8), 3= 49/ Mechanical, (min. 0-1-8), MiTek recommends that Stabilizers and required cross bracing be 4=-84/ Mechanical, (min. 0-1-8) installed during truss erection, in accordance with Stabilizer Max Horiz 2=124 (LC 12) Installation guide. Max Uplift 2=-375 (LC 12), 3=-49 (LC 1), 4=-84 (LC 1) Max Grav 2=383 (LC 1), 3=75 (LC 12). 4=122 (LC 12) FORCES (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-336/137 BOT CHORD 2-4=-164/406 NOTES 1) Wind: ASCE 7-22; Vult=160mph (3-second gust) Vasd=124mph, TCDL=4.2psf; BCDL=5.8psf; h=15ft; B=50ft; L=30ft; eave=lft; Cat. II; Exp C; Enclosed; MWFRS (directional) and C-C zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 3, 375 lb uplift at joint 2 and 84 lb uplift at joint 4. LOAD CASE(S) Standard EXHIBIT - 026 - PAGE - 007 OR - � Ir ;1�' ;► 1(r:, l �rr.r�: If �ijifl 1�+'1 iii 'rl i#i o� Ig ,J. ��►� ®aaoo �' �� ►jjl #l� I'ti,J aitjli ill+ ;lil� J;1 �l �} r�J• . ]i �til #it �+iitr l��if•+ �r;J iJJI[ iJ; i�;� 1 � rs"3s. xJ�. ! m®000 it fillIlliri �iirdF Dili J'ri�l iiJ i}I fill i z a a a a z „0 Zl „0 ,£ „0 ,Z r.0 ,Z „0 ,£ P 9 W W W W � o Lr �L 0 N 8L 0 CV o VL V L 0 CV 8L O <V DL 0 �, Lr '913 iv-ljl'.0-,04 � W W W W '7 0 ,£ „0 ,Z „0 ,Z'� A ,£ Lr ►.r cn W o W c5 x LU F- LL J a D O z to m J 0 O O N cn ❑ W EXHIBIT - 026 - PAGE - 008 Copier County GrvMh Management This form can be uploaded to the portal once Need Help? community Dm1cpmant Depnnmonl the subcontractor condition has been added. GMCD Public Portal 1 Permit Number: PRAC20241042897 Job site Address: 2225 23 rd Street SW The below named subcontractor hereby requests to be added to the permit files for the building permits listed above. I hereby agree to comply with the County Building requirements and all provisions of the laws of the State of Florida, and all regulations relating to or applying to building, plumbing, electrical, roofing and air conditioning construction. I certify that the information pertaining to my trade on the application is true and correct to the best of my knowledge and belief. Provide as applicable to scope of work: ❑ Electrical Contractor ❑ Mechanical Contractor ❑ Plumbing Contractor (] Roof Contractor ❑ Septic Contractor ❑ Low Voltage Contractor ❑ Pool Contractor (if permit applied for by a general contractor) ❑ Contractor Other Company Name: Jasinskl Builders, LLC License#: LCC20220001359 Qualifier Name: Kristen jitasinski Qualifier Signature: Subcontractor List 9/2023 Date: 07/10/25 Page 1 of 1 EXHIBIT - 027 - PAGE - 001 Code Case Details Execution Date 12/8/2025 4:08:33 PM Desc Assigned Required Completed Outcome Comments Re -Inspection BrianOwen 4/212025 4/2/2025 Non- (Demo permit PRDM20241042895 for old Compliant pump house is in 'Issued" status with an expiration date of 04/29/2025. Permit PRAC20241042897 for a new pump house is in "Issued" status with an expiration date of 09/13/2025. Ms Jasinski is meeting with Robert Moore from developmental review to discuss abatement plan. Violation remains, fines continue to accrue.) Re -Inspection BrianOwen 5/2/2025 5/1/2025 Non- Permit PRDM20241042895 is in "issued" Compliant status. Exp date 4/29/25. OwenBrian 05/01 /2025 9:17 AM Re -Inspection BrianOwen 5/16/2025 5/15/2025 Non- Permit PRDM20241042895 is in "issued" Compliant status. Exp date 4/29/25. Permit is now expired. Permit PRAC20241042897 is in "issued" status. Exp date 9/13/25. OwenBrian 05/15/2025 2:35 PM Schedule Case for Hearing Danielle.Dijan 7/10/2025 7/10/2025 Complete Case scheduled for the August 1, 2025 OSM IOF Hearing / DD Generate Hearing Notice (CE) Danielle.Dijan 7/10/2025 7/10/2025 Complete Hearing Notice Service/Posting BrianOwen 7/10/2025 7/10/2025 Complete Last date to post is July 16, 2025 / DD ;E Staff Review Danielle.Dijan 7/10/2025 7/15/2025 Complete AOM & AOP notarized, scanned & attached / DD CE Mailing Danielle.Dijan 7/10/2025 7/10/2025 Complete Notice of Hearing sent regular and evidence packet mailed certified for the August 1, 2025 OSM IOF Hearing / DD Affidavit of Service/Posting BrianOwen 7/10/2025 7/10/2025 Complete Re -Inspection BrianOwen 7/15/2025 7/14/2025 Non- Permit PRAC20241042897 is in "inspections Compliant commenced" status. Issued 3/17/25. Exp date 1 /10/26 Permit PRDM20241042895 is in "issued" status. Exp date 4/29/25. Permit is now expired. Permit PRFH2O241041232 is in "ready for issuance" status. App date 10/14/24. Exp date 12121 /25 OwenBrian 07/14/2025 7:51 PM CE Legal Review Miriam.Lorenz 7/15/2025 7/10/2025 Schedule Added to spreadsheet for IOF approval./ML o for SM/CEB Pre Hearing Inspection BradleyHolme 7/31/2025 7/31/2025 Complete 7-31-2025 Permit Check completed: s Permit # PRDM20241042895 - exp. 4/29/2025 - status: Issued *EXPIRED` Permit # PRAC20241042897 - exp. 1/11/2026 - status: Inspections Commenced Violation remains. BH91 Business Management & Budget Office 5 EXHIBIT - 028 - PAGE - 001 Collier County Payment Slip - Permits Date: July 17, 2025 Contact: Kristen Jasinski 2805 Horseshoe Drive S, #10 Naples, FL 34104 owner: BUOYANCY LLC Contractor: JASINSKI BUILDERS, LLC Permit Location: 2225 23rd ST SW, Naples Job Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. REV 1: Submitting Truss Plans 2225 23rd ST SW, Naples FEES: Description implication Number jPermit Number Fee Paid Fee Revision PRAC20241042897 IPRAC2024104289702 $50.00 $0.00 Total: $50.00 $0.00 Bonds: The following conditions must be satisfied before your permit can be issued: The following conditions must be satisfied before you can call your first inspection: > Revision Inspection Hold. This condition will be resolved once the revision has been issued. You can track your permit using the following link: https://cvportal.colliercountyfl. gov/CityViewWeb//Permit/StatusReference?referenceN umber=PRAC20241042897 To pay online use the following link; https://cvportal.colliercountyfl.gov/CityViewWeb/ Must be a GMD Public Portal registered user to make payment. EXHIBIT - 029 - PAGE - 001 VACHT10 i A Kristen Jasinski <kristen@napiesfloridavacationhomes.com> RE: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure 1 message Joe Bianchi<Joe.Bianchi@colliercountyfl.gov> Mon, Jul 28, 2025 at 3:11 PM To: Robert Moore <Robert.Moore@colliercountyfl.gov>, Dianna Perryman <Dianna.Perryman@colliercountyfl.gov>, Kristen Jasinski <kristen@jasinskibuilders.com> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>, Brian Owen<Brian.Owen@colliercountyfl.gov>, Myron Jacobs <Myron.Jacobs@colliercountyfl.gov> 810 Exotic Vegetation Removal and is typically done at the end, there are 13 species required to be removed from the entire property. Joe Bianchi Supervisor - Site Inspections Development Review Office:239-252-2391 Mobile:239-877-8031 2800 Horseshoe Drive N Naples, FL 34104 Joe. Bianchi@colliercountyfl.gov -t Collier County J 93@00M From: Robert Moore<Robert.Moore@colliercountyfl.gov> Sent: Monday, July 28, 2025 3:02 PM To: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov>; Kristen Jasinski <kristen@jasinskibuilders.com> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>; Brian Owen<Brian.Owen@collie rcountyfl.gov>; Myron Jacobs <Myron.Jacobs@colliercountyfl.gov>; Joe Bianchi<Joe.Bianchi@colliercountyfl.gov> Subject: RE: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure Good afternoon Kristen, We are unable to schedule the 188 and 119 inspections until the spot survey is submitted and approved. I have copied Joe Bianchi to assist with your 810 Exotic Vegetation inspection questions. Robert Moore Manager - Plans Review & Inspections Building Plan Review & Inspection Offlce:239-252-2422 2800 North Horseshoe Drive Naples, FI 34104 Robert,Moore@colliercountyfl.gov Collier County U@OnC From: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov> Sent: Monday, July 28, 2025 2:33 PM To: Kristen Jasinski <kristen@jasinskibuilders.com>; Robert Moore <Robert.Moo re@colliercountyfl.gov> EXHIBIT - 030 - PAGE - 001 EXTERNAL EMAIL; This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Hello Dianna, Thank you for your help recently to schedule two inspections for the permit PRAC20241042897 at 2225 23rd Street SW Accessory Structure. We are now trying to schedule the 118 Lintel Beam and 119 Fill Cells Inspections. I believe the spot survey might be holding up our ability to schedule these inspections. We requested a spot survey from our surveyor on July 18th just as soon as we finished pouring the monolithic slab. He said it would be 2-3 weeks before he could get to it. Since this well house is greater than 76' feet from the nearest lot line and 46'+ from any setback, I am completely confident the spot survey won't be a problem. For safe measure I also had the concrete slab poured a few inches higher than what was required. For quick reference I am including a copy of the approved plans. The job is ready for the above inspections. I would appreciate it if we can schedule these inspections for Tuesday, July 28th. Please also know that construction of this new well house Accessory Structure is necessary so that we can move all water treatment and well equipment from an old unpermitted structure (Demolition permit PRDM20241042895). This is to close out a code enforcement case CESD20240001061 for the old well house which was unpermitted. The Code Enforcement folks are of course pressing to see progress toward resolving open cases. Our ability to start the Accessory Structure has been delayed because the electricity to the well house was part of service and electrical upgrades tied to permit PRFH20241041232 which was just approved. One last question with respect to inspections on Accessory Structure - When is the 810 Exotic Vegetation Removal inspection supposed to take place? This work did not include the removal of any trees, bushes or plants. Can you tell me what they are looking for in that inspection and when it is supposed to be done? I am easily reached on my cell at 847-902-9133 if you need to reach me. Thank you Diana for your assistance to override stops / delays programmed into your portal. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 '— BUILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 1" 239-296-8800 EXHIBIT - 031 - PAGE - 001 IN Kristen@JasinskiBuilders.com Under Florida Law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. EXHIBIT - 031 - PAGE - 002 PAC$TIOR Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Re: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Mon, Jul 28, 2025 at 7:23 PM To: Robert Moore <Robert.Moore@colliercountyfl.gov> Cc: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov>, Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>, Brian Owen <Brian.Owen@colliercountyfl.gov>, Myron Jacobs <Myron.Jacobs@colliercountyfl.gov>, Joe Bianchi<Joe.Bianchi@colliercountyfl.gov> Robert, For the record, this project is further delayed by the fact that the surveyor is not able to complete a spot survey for another 3 weeks. On July 15th, the Monolithic Slab inspection was approved. We poured the slab on 7/18 and ordered the spot survey on the same day. Today our surveyor confirmed he will not be able to complete the spot survey before 8/15. We have inquired with several other surveyors and all are backed up and cannot complete the spot survey any sooner. Well house and water treatment equipment cannot be moved until the new accessory structure is completed. Demolition of 25+ year old unpermitted well house cannot be completed (Permit # PRDM20241042895) until the new well house is built. This further delays resolution of Code Enforcement Case CESD20240001061. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 BUILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S. #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com On Mon, Jul 28, 2025 at 3:01 PM Robert Moore <Robert.Moore@colliercountyfl.gov> wrote: Good afternoon Kristen, We are unable to schedule the 188 and 119 inspections until the spot survey is submitted and approved. I have copied Joe Bianchi to assist with your 810 Exotic Vegetation inspection questions. Robert Moore Manager - Plans Review & Inspections Building Plan Review & Inspection Office:239-252-2422 2800 North Horseshoe Drive Naples, FI 34104 Robert.Moore@colIiercountyfl.gov Collier County U@80M From: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov> Sent: Monday, July 28, 2025 2:33 PM To: Kristen Jasinski <kristen@jasinskibuilders.com>; Robert Moore<Robert.Moore@colliercountyfl.gov> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>; Brian Owen <Brian.Owen@colliercountyfl.gov> Subject: RE: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure EXHIBIT - 032 - PAGE - 001 Good afternoon Kristen, We are unable to schedule the 188 and 119 inspections until the spot survey is submitted and approved. I have copied Joe Bianchi to assist with your 810 Exotic Vegetation inspection questions. Robert Moore Manager - Plans Review & Inspections Building Plan Review & Inspection Office:239-252-2422 Collier County J 2800 North Horseshoe Drive Naples, FI 34104 Robert.Moore@colliercountyfl.gov From: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov> Sent: Monday, July 28, 2025 2:33 PM To: Kristen Jasinski <kristen@jasinskibuilders.com>; Robert Moore<Robert.Moore@colliercountyfl.gov> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>; Brian Owen<Brian.Owen@colliercountyfl.gov> Subject: RE: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure Good afternoon, Kristen, I'm glad I could assist. Please note that my role is not to override the permitting process, but to ensure that the procedures we have in place are ..,, being properly applied to your permits. As a reminder, you were instructed to contact either Robert Moore or one of the Chiefs to schedule your inspection. The questions you've listed below require responses from a reviewer, manager, or chief —as I am not a reviewer, I'm unable to provide those answers. To ensure you receive the appropriate guidance, I'm forwarding this message —and the additional email you sent —to Mr. Moore for review. Respectfully, Dianna Perryman Management Analyst I Operations & Regulatory Management Office:239-252-2965 2800 North Horseshoe Drive Naples, FL 34104 Dianna.Perryman@colliercountyfl.gov -t Collier County 0@80M From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Monday, July 28, 2025 2:15 PM .i, To: Dianna Perryman <Dianna.Perryman@colliercountyfl.gov> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>; Brian Owen <Brian.Owen@colliercountyfl.gov> Subject: Fwd: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure EXHIBIT - 033 - PAGE - 001 "I.,0,>TIQP Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Re: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Mon, Jul 28, 2025 at 7:01 PM To: Joe Bianchi <Joe.Bianchi@colliercountyfl.gov> Cc: Robert Moore <Robert.Moore@colliercountyfl.gov>, Dianna Perryman <Dianna.Perryman@colliercountyfl.gov>, Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>, Brian Owen<Brian. Owen@colliercountyfl. gov>, Myron Jacobs <Myron.Jacobs@colliercountyfl.gov> Joe, Thank you for your response to clarify my question about the 810 Exotic Vegetation Removal Inspection. For over a month I have made multiple calls to the County asking what that inspection was and when it was supposed to take place, Every person I spoke to in Customer Service and Inspections couldn't answer the question. was referred to Robert Moore. I left voice mails with Robert. I also emailed Mr. Moore on July 2nd and never received a response. Thank you Dianna Perryman for your assistance in finally prompting those to get a response to my question. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 tSUILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S. #10 Naples, FL 34104 �- 239-296-8800 Kristen@JasinskiBuilders.com On Mon, Jul 28, 2025 at 3:11 PM Joe Bianchi<Joe.Bianchi@colliercountyfl.gov> wrote: 810 Exotic Vegetation Removal and is typically done at the end, there are 13 species required to be removed from the entire property Joe Bianchi Supervisor - Site Inspections Development Review 1 Office:239-252-2391 Collier Count` r Mobile:239-877-8031 2800 Horseshoe Drive N Naples, FL 34104 Joe.Bianchi@colliercountyfl.gov = 311 From: Robert Moore <Robert.Moore@colliercountyfl.gov> Sent: Monday, July 28, 2025 3:02 PM To: Dianna Perryman <Dianna. Perryman@colliercou ntyfl.gov>; Kristen Jasinski <kristen@jasinskibuilders.com> Cc: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov>; Brian Owen <Brian.Owen@colliercountyfl.gov>; Myron Jacobs <Myron.Jacobs @colliercountyfl.gov>; Joe Bianchi<Joe.Bianchi@colliercountyfl.gov> Subject: RE: Request for assistance with scheduling inspections for 2225 23rd Street SW Accessory Structure EXHIBIT - 034 - PAGE - 001 14 NW Cower County Growth Management Community Development Department For sheds 200 sq ft or less STATE OF FLORIDA COUNTY OF COLLIER Need Help? GMCD Public Portal Bulletin #21 Permit #: PRAC20241042897 1 Kristen Jasinski do hereby affirm that the work performed at address: 2225 23rd Street SW shall conform to the applicable setback(s), elevation, and easement requirement(s) established by the Collier County Land Development Code and/or any other applicable agency. If an encroachment does occur, I hereby agree to relocate this structure to conform to such setbacks. (Select one): 0 OWNER -BUILDER V CONTRACTOR Signed.—::� 0 DESIGN PROFESSIONAL Printed Name: Kristen Jasinski State of Florida Countyof Collier The foregoing instrument was acknowledged before me by means of G physical presence or C online notarization this: 31St dayof July ,2025 , by (printed name of owner or qualifier) Kristen Jasinski Such person(s) Notary Public must check applicable box: 0 Are personally known tome ' WESLEY JASINSKI (] Has produced acurrent driverslicense ,�.•�`'' ',, 0 Hasproduced as identification. 5 Notary Public -State 5 6. -` Flo- Commiaaion i HH 636: ,.� My Commission Expi� NotarySignature: ""'"'` October 04, 2028 Spot Survey Waiver-1 -1 -24 Page 1 of 1 Operations and Regulatory Management • 2800 North Horseshoe Drive • Naples, FL 34104 • 239-252-2400 www colhercountyfl aov/ EXHIBIT - 035 - PAGE - 001 Code Case Details Execution Date 12/8/2025 4:08:33 PM Desc Assigned Required Completed Outcome Comments Record Hearing Results Miriam.Lorenz 8/4/2025 8/4/2025 Complete 8-1-25 Respondent Kristen Jasinksi o Contractor/Partial owner was present. The Special Magistrate continues this case to the November 7, 2025, OSM Hearing, Fines do not continue to accrue as of today's hearing, also Respondent is ordered to pay operational costs incurred in the prosecution of this case in the amount of $111.90, to be paid on or before (30 days) August 31, 2025./ML Re -Inspection BrianOwen 8/15/2025 8/15/2025 Non- Permit PRAC20241042897 is in "inspections Compliant commenced" status. Issued 3/17/25. Exp date 2/11 /26 Permit PRDM20241042895 is in "reactivate" status. Exp date 1 Ill 1/25 Permit PRFH2O241041232 is in "issued" status. App date 10/14/24. Exp date 1/28/26. OwenBrian 08/15/2025 12:13 PM CE Mailing Danielle.Dijan 8/18/2025 8/18/2025 Complete Mailed copy of Continued IOF Order (not recorded) to respondent from the August 1, 2025, OSM IOF Hearing — DID Generate Hearing Results Notice Danielle.Dijan 9/l/2025 8/25/2025 Complete Recorded 8/20/25 OR 6500 PG 1144 / DID (CE) 8/18/2025 - Scanned & attached Continued IOF Order (not recorded) from the August 1, 2025, OSM IOF Hearing and sent Order to be recorded - DID Re -Inspection BrianOwen 9/15/2025 9/15/2025 Non- Permit PRAC20241042897 is in "inspections Compliant commenced" status. Issued 3/17/25. Exp date 3/l /26 Permit PRDM20241042895 is in "inspections commenced" status. Issued date 10/31/24. Exp date 2/15/26 Permit PRFH2O241041232 is in "inspections commenced" status. App date 10/14/24. Issued date 8/l/25. Exp date 2/24/26. OwenBrian 09/15/2025 12:32 PM Lien Search/Payoff Request MarieCheri 9/24/2025 9/24/2025 Complete Payoff sent to Jonathan Scott; document attached me Not Applicable BrianOwen 10/9/2025 10/9/2025 Not Required Not Applicable BrianOwen 10/9/2025 10/9/2025 Not Required Post Hearing Re -Inspection BrianOwen 1019/2025 1019/2025 Non- Permit PRAC20241042897 is in "revision - Compliant rejected" status. Issued 3/17125. Exp date 3/15/26 Permit PRDM20241042895 is in "inspections commenced" status. Issued date 10/31/24. Exp date 2/15/26 Permit PRFH2O241041232 is in "inspections commenced" status. Issued date 8/l/25 Exp date 2/24/26. Violations have not been abated. OwenBrian 10/09/2025 7:24 AM Business Management & Budget Office EXHIBIT - 036 - PAGE - 001 t l VACATION Kristen Jasinski <kristen@naplesflo rid avacationhomes. com> � CESD20240001061 -Well House 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Sun, Aug 3, 2025 at 4:16 PM To: Bradley Holmes<bradIey.holmes@colliercountyfl.gov>, Brian Owen<brian.owen@colliercountyfl.gov>, Jeffrey Letourneau <jeffrey. Leto urneau@colIiercountyfl.gov> Bradley & Brian, The well house which you say was never permitted is a small framed shed built to house and protect the well pump and water treatment equipment within. It is +/- 100sf and so I very much believe there may have been no provision requiring a permit for such small structures at the time it was built. The structure existed and was already very aged when Buoyancy, LLC acquired the property in September 2010. 1 believe this code enforcement case should be dismissed and all fines levied should be reversed at once. Referring back to the plans from when the subject home was permitted back in 1998, those plans are stamped specifying construction will be in accordance with the Unified Land Development Code, .... and the Standard Building Codes 1994 edition as amended by the Collier County Construction Code Ordinance 96-26. Can you provide me with a copy of the Collier County Construction Code Ordinance 96-26 as it existed when the property was permitted or direct me to where I can review the ordinance in effect as of the date the permit was either applied for (1/15/1998) or approved (2/6/1998)? Are there aerial photos which pre -date those available on Collier Appraisers website which show when the well house was built? I have reviewed the Standard Building Code 1994 in detail. This pertains primarily to structures more commercial in nature. Very little information is provided regarding 1-2 Family Residential structures, with the exception of high-rises, multi -family buildings, etc. intended for dense occupancy. In fact Appendix C on page 715 for One and Two Family Dwellings says that "dwellings not more than three stories in height or their accessory structures shall be permitted to be designed and constructed in accordance with the CABO One and Two Family Dwelling Code". The plan for 2225 23rd Street SW, makes no mention of CABO One and Two Family Dwelling Code and specifically which version year Collier County may have had adopted as of early 1998 when this 1-2 family residential property was permitted. While reviewing Aerial photos from the Collier Appraiser website, I noticed issues at neighboring properties which should be reviewed. Photos attached. There is concern for a shed at the back of 2259 23rd Street SW which seems to sit on the lot line or encroaches onto our lot. I believe there is a clear setback violation at the very least. Was this structure ever permitted? If so, when? Our parcel for 2213 23rd Street SW includes the whole of the canal with the property line backing up to 2180 Della Drive and 2224 Della Drive. Have the structures all been permitted and meeting setback requirements particularly at 2224 Della Drive? As as consequence of the code enforcement case the new permits obtained required us to do an Exotic Vegetation Removal / inspection. The ariel as attached show a failure to maintain vegetation growth on all adjoining lots at 2180 Della, 2224 Della, 2259 23rd Street SW and 2181 23rd Street SW. I would appreciate it if Code Enforcement can investigate these matters further both for structures on adjacent parcels as well as maintenance of vegetation growth. Thank you for your assistance. I look forward to your reply. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 Ar BUILDERS EXHIBIT - 037 - PAGE - 001 Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com On Tue, Aug 5, 2025 at 10:55AM Kristen Jasinski <kristen@jasinskibuilders.com> wrote: Hello, This request is for ariel photographs of the whole of Tract 6, Golden Gate Estates, Unit 195 as far back as 1995. Please note this 5+ acre parcel was commonly known for years as 2225 23rd Street SW for many years. In 2020 the lot was split generally front to back creating a new address for the back parcel of 2213 23rd Street SW and keeping 2225 23rd Street SW for the front parcel with a large home. The purpose of this request is to determine when a small shed was built on the property. Please provide any and all ariel photos for this parcel of land between the dates of 1998 and 2018. If you have further questions, I can be reached at 847-902-9133. Thank you for your assistance. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com EXHIBIT - 038 - PAGE - 001 VrCA117109 tircE: 2225 23rd Street SW & 2213 23rd Street SW 1 message Ernie W Kerskie <ekerskie@collierappraiser.com> Reply -To: ekerskie@collierappraiser.com To: Kristen Jasinski <kristen@jasinskibuilders.com> I% - Hello Ms. Jasinski, Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Tue, Aug 5, 2025 at 2:15 PM We have digital aerials back to 2000, prior to that we have mylar hardcopy at a greater scale that we can view from a lightboard. I believe you mean All Tract 5 not Tract 6. Tract 5 is owned by Buoyancy LLC (your LLC). The 2000 aerial is not the greatest resolution but appears to show something where you are looking for the shed with a possible "shiny" roof that distorts the aerial. In 2001 you can definitely see a structure where the shed currently is located. I enclosed a 2025 aerial for further clarification. The next oldest year is 1996 and I do not have an aerial to share digitally, but I reviewed it on the lightboard and could not discern any structure on the vacant Tract 5 through the trees at its southwestern corner. I really do not have anything else between 1996 and 2000. There is no shed being assessed on the property card nor was there ever one listed. That is not unusual as we treat most sheds as personal property and do not pick them up for assessment. I hope this helps, If I had to guess the permit was pulled in 1998, sometime after that ground was disturbed for Tract 5 throughout the property and it looks as though a shed appeared in 2000. if you need a date prior to that, we may have something in our old books in storage around the 1995-1999, but again I could not see anything on the 1995 mylars. 2001 and 2025 aerials are sent separate email due to size of pdf file. Respectfully, Ernie W. Kerskie Mapping Department Office of the Collier County Property Appraiser 239-252-8161 From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Tuesday, August 5, 2025 10:57 AM To: webinfo@collierappraiser.com Subject: Re: 2225 23rd Street SW & 2213 23rd Street SW Resending request for 2225 & 2213 23rd Street SW. Photo of location of well house / shed is attached. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 EXHIBIT - 039 - PAGE - 001 From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Tuesday, August 5, 2025 6:29 PM To: ekerskie@collierappraiser.com Subject: Re: 2225 23rd Street SW & 2213 23rd Street SW Ernie, Thank you very much for your prompt response and research. I think the information your aerial photos provide is sufficient to answer my question. Do you have a specific date of when the photos were taken to include month and day? Certificate of Occupancy was issued March 13, 2000 so it would be good to know if the shed existed before the final inspection / approval from the County. The well comes up inside the shed and so I believe the shed was built sometime after the well was drilled. The well was inspected and approved on 1/22/1999. You mentioned that it's common for the appraiser's office to classify small sheds as personal property and therefore not include them in the property card. Are there other determining factors which also contribute to that decisions as well? For example the square footage of the structure or type of construction (masonry or framed) or whether the structure may have been included as part of the overall permit application to build the house? The records from the building department are somewhat vague. Are there any records other than Aerial photos which the Appraisers office might have. These days the permitting standards are quite different and require separate permits for the accessory structures and for the well itself. Back then it seems the well (and who knows accessory structure) might have all been included under one single permit. Thank you again for your help and for any guidance you can provide. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 If B J I L D E RS EXHIBIT - 039 - PAGE - 002 pgQ;gjpp Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Fwd: 2225 23rd Street SW & 2213 23rd Street SW 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Wed, Aug 6, 2025 at 5:24 PM To: Bradley Holmes<bradley.holmes@colliercountyfl.gov>, Brian Owen<brian.owe n@colliercountyfl.gov> Cc: Jeffrey Letourneau<jeffrey.letourneau@colliercountyfl.gov> Bradley / Brian, This follows up to my email earlier this week pertaining to Code Enforcement Case, CEAU20240001061. We were cited for an unpermitted structure which is a small wood -framed shed less than 100sf which houses well and water treatment equipment. We have researched this matter further by requesting copies of aerial photographs from the Collier Appraisers office. As per the email below, there are in fact aerial photographs from the appraiser's website which establish that this shed was in fact built in tandem with the well and main house. The Appraiser's office has provided aerial photos (dated January 2000) which show the shed clearly existed prior to the Certificate of Occupancy being issued in March 2000. Additional photos are shared to show the shed is still in the exact same position and angle as it was originally built. The well itself comes up inside of this shed and this shed also has electrical panels with breakers and outlets attached to it's walls which of course provides power to the well and other water treatment equipment within. Collier County inspectors not only inspected the well as part of the house permit but also certainly would have inspected the electrical breakers and outlets within the well shed. Also, in reviewing the building records, the inspection list for the main house had an approved inspection for the well itself which was approved 1/22/1999. This makes it clear that the practices for permitting in 1998 - 2000 was very different than it is today. Today we would have to pull a separate permit for the house, for the well, for the septic, for an accessory structure, etc. However, back then given the fact that the well inspection, septic, etc. were included under the House's permit, it proves that practices were very different then. Building the well, and the well house was incorporated into the construction of the main house. Surely the county wouldn't have allowed a home to get built which had no water source. Attached for your convenience is the inspection card from your building records as well as the Certificate of Occupancy. Since the shed existed at the time certificate of occupancy was issued in March 2000 as proven by aerial images obtained by Collier's Property Appraiser, and the fact that well and septic were incorporated into the same permit, Code Enforcement's Citation for an this being an "unpermitted structure" is wrongful. The well house existed in it's very same location when the property was inspected multiple times leading up to Certificate of Occupancy being issued. This structure is also clearly visible from aerial view, from the road, from looking out into the back yard or walking around the house. I respectfully request that the County immediately dismiss this case and reverse all fines accrued. I look forward to your favorable response. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 I�5�5K�Ii ��Bl11LDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com EXHIBIT - 040 - PAGE - 001 ---------- Forwarded message --------- From: Ernie W Kerskie <ekerskie@collierapp raiser. com> Date: Wed, Aug 6, 2025 at 11:33AM Subject: RE: 2225 23rd Street SW & 2213 23rd Street SW To: Kristen Jasinski <kristen@jasinskibuilders.com> Kristen, "Thank you very much for your prompt response and research. 1 think the information your aerial photos provide is sufficient to answer my question. Do you have a specific date of when the photos were taken to include month and day? Certificate of Occupancy was issued March 13, 2000 so it would be good to know if the shed existed before the final inspection / approval from the County. " I have attached another aerial from our records from January 2000 that I found on an individual DVD. It has better resolution than the earlier aerial I sent for 2000 but is the same image only a different file/compression type. The image resolution from February 1999 from the books in storage is not legible enough to read. You can barely see the house image, let alone where the shed/well was located. "The well comes up inside the shed and so 1 believe the shed was built sometime after the well was �-- drilled. The well was inspected and approved on 112211999. " "You mentioned that it's common for the appraiser's office to classify small sheds as personal property and therefore not include them in the property card. Are there other determining factors which also contribute to that decisions as well? For example the square footage of the structure or type of construction (masonry or framed) or whether the structure may have been included as part of the overall permit application to build the house? " Typically a shed is not picked up for assessment as real property if it looks like the "ted shed" type of structure that is moveable, it does not depend on size. Its possible at the time of our inspection for the assessment of the real property that occurs after we receive notification of building substantially complete or a copy of the C/O that the shed was missed due to its location on the property. That is only a guess on my part because it does not show up drawn on the property card. It was also not picked up in subsequent years when various other improvements were replaced or permitted and we were on site. "The records from the building department are somewhat vague. Are there any records other than Aerial photos which the Appraisers office might have. These days the permitting standards are quite different and require separate permits for the accessory structures and for the well itself. Back then it seems the well (and who knows accessory structure) might have all been included under one single permit." I agree to the vagueness of older ways they permitted and also the lost records. I thought if you could prove it existed since a certain time, GMD allowed you some latitude. It does seem prudent that a well and accessory structure where done at same time as the residence back in the day or EXHIBIT - 040 - PAGE - 002 that they didn't even care about small accessory structures. Our office only has information that is on the property card and aerials that can paint a picture of what has happened over time, no other real substantive information is memorialized. The property card is important because it shows changes over time, although your card has minimal information such as aluminum screen enclosure changed 2006-7, property split in 2020 tax roll, various permits from 2000(pool), 2000 (alse),2006(roof),2006 (guest house — cancelled). I hope your situation is resolved to your benefit. Good Luck Respectfully, Ernie W. Kerskie Mapping Department Office of the Collier County Property Appraiser 239-252-8161 Thank you again for your help and for any guidance you can provide. EXHIBIT - 040 - PAGE - 003 Address, C222b z3ra Street bvv oe-r bounty JI ? INDEX SHEET: Wvoe)) Growth Management �— Community Development Department FL PRODUCT APPROVAL MIAMI-DADE NOAS Include complete product number with decimal. Example: 20-0619.03 or 21563.2 Section A: i DOORS # COMPONENT MANUFACTURER/MODEL IMPACT FL PA/NOA # Exp. Date Design Pressure 68.12 g g 2 iSliding L 'r r Cass 7Wk; Yt3 73 Lo V+.T ° 1 3 ! Garage S 7 + - ' ----- - - - - - - 8 I + Section B: WINDOWS # COMPONENT MANUFACTURER/MODEL IMPACT FL PA/NOA # Exp. Date Design Pressure 1 ',Single/Dbl Hung + 2 Fixed + 3 Casement 1- — .28 08� 12 04/4�202&- + 4 ;Horizontal Slider; f �►T _ C121s�`li�iL. 5� t t� C1I� %_ 23' _ 70%0d 5 iMullion + 6 jSkylights f , 7' + 8 + �.. 9 - - 10 + Section C: ROOFING PRODUCTS # COMPONENT MANUFACTURER/MODEL FL PA/NOA # Exp. Date Design Pressure 1 'Asphalt Shingles i+ 2 Metal + 3 Tile Santa Fe Clay Tile 21-0614.05 2/1/26 + 4 !Single Ply + 5 i Underlayment I Sentry LapLock ESR-4054 July, 2025 + 6 Vents + + 7 8 + .Section D: STORM SHUTTERS # COMPONENT MANUFACTURER/MODEL FL PA/NOA # Exp. Date Design Pressure 1 + 2 ` 3 Section E: PANEL WALLS # COMPONENT MANUFACTURER/MODEL FL PA/NOA # Exp. Date Design Pressure 1 Soffits + 2 Storefront 3 _ + - 4 + - PRODUCT APPROVALS/NOAs MUST BE ONSITE AT TIME OF INSPECTION Building Plan Review Inspection Division • 2800 North Horseshoe Drive • Naples, FL 34104 • 239-252-2400 FL Product Approval NOA Index Sheet - 1-1-24 www.colliercountyfl.gov/ Page 1 of 1 EXHIBIT - 041 - PAGE - 001 I-- EXHIBIT - 041 - PAGE - 002 Kristen Jasinski <kristen@naplesfioridavacationhomes.com> Re: CESD20240001061 -Well House -i message Kristen Jasinski <kristen@jasinskibuilders.com> Fri, Aug 22, 2025 at 3:01 PM To: Bradley Holmes<bradley. holmes@colliercountyfl.gov>, Brian Owen<brian.owen@colliercountyfl.gov>, Jeffrey Letourneau <jeffrey. Letourneau@colliercountyfl.gov> Gentleman, I am resending the following email which was sent on August 3rd. In checking the County Portal it seems no action has been taken with respect to the shed at 2259 23rd Street SW which appears to encroach certainly into side yard setback, if not encroaching upon our property line. Please advise. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 (7��5K�li ��� Bll l LD E RS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com On Sun, Aug 3, 2025 at 4:16 PM Kristen Jasinski <kristen@jasinskibuilders.com> wrote: Bradley & Brian, The well house which you say was never permitted is a small framed shed built to house and protect the well pump and water treatment equipment within. It is +/- 100sf and so I very much believe there may have been no provision requiring a permit for such small structures at the time it was built. The structure existed and was already very aged when Buoyancy, LLC acquired the property in September 2010. 1 believe this code enforcement case should be dismissed and all fines levied should be reversed at once. Referring back to the plans from when the subject home was permitted back in 1998, those plans are stamped specifying construction will be in accordance with the Unified Land Development Code, .... and the Standard Building Codes 1994 edition as amended by the Collier County Construction Code Ordinance 96-26. Can you provide me with a copy of the Collier County Construction Code Ordinance 96-26 as it existed when the property was permitted or direct me to where I can review the ordinance in effect as of the date the permit was either applied for (1/15/1998) or approved (2/6/1998)? Are there aerial photos which pre -date those available on Collier Appraisers website which show when the well house was built? I have reviewed the Standard Building Code 1994 in detail. This pertains primarily to structures more commercial in nature. Very little information is provided regarding 1-2 Family Residential structures, with the exception of high-rises, multi -family buildings, etc, intended for dense occupancy. In fact Appendix C on page 715 for One and Two Family Dwellings says that "dwellings not more than three stories in height or their accessory structures shall be permitted to ti be designed and constructed in accordance with the CABO One and Two Family Dwelling Code". The plan for 2225 23rd Street SW, makes no mention of CABO One and Two Family Dwelling Code and specifically which version year Collier County may have had adopted as of early 1998 when this 1-2 family residential property was permitted. EXHIBIT - 042 - PAGE - 001 S, hl.. ills..!, )palC�TJ09 ,;. �- ROMIgt Re: Code Cases Opened 1 message Kristen Jasinski <kristen@jasins kibuilders.com> To: Bradley Holmes <Bradley.Holmes@colliercountyfl.gov> Cc: Jeffrey Letourneau <Jeffrey.Letourneau@colliercountyfl.gov> Bradley, Kristen Jasinski <kristen@naplesfiorid avacationhomes. corn> Tue, Aug 26, 2025 at 3:33 PM I don't believe there are any issues with structures at 2181 23rd Street SW. There is not a new structure to my knowledge nor do I have any knowledge of a structure in the heavily wooded area. I believe the only issue with 2181 23rd Street is that they don't maintain the heavy vegetation at back of their lot lot and so there is a lot of vegetation which appears to have grown into our lot. We have to remove exotics from our lot and if they don't address them as well, it's just a question of time before the exotics continue to over take. The only problem with a structure for neighboring properties specifically on 23rd is the shed which sits on or way too close to the property line on the 2259 parcel. Sorry if I perhaps was unclear or misspoke in a prior email. On Della (across the canal from us) - vegetation, unpermitted structures and also storage of lots of junk and/or construction equipment/materials is an issue. Yes, you have my consent to enter the parcels owned by Buoyancy LLC. To get back to that shed from our parcel you need to enter the parcels for both 2225 and 2213 23rd Street SW (both owned by Buoyancy) and yes, I will sign an entry consent. We are about to start digging a trench for upgrading electrical service to 2225 23rd Street SW so the driveway which gives access to 2213 23rd Street SW will be impassable from tomorrow for about a week. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 E RS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuiIders.com On Tue, Aug 26, 2025 at 11:30AM Bradley Holmes <Bradley.Holmes@colliercountyfl.gov> wrote: Kristen, have a question regarding 2181 23rd ST SW: I am researching the aerials to locate a structure that would be violating setback and/or is perhaps unpermitted. From aerials, I can only see a residential structure. Is there a structure on -site that is newer than January 2025 (would not show on the current aerial) or is tucked into a wooded area? I like to know ahead of my initial inspection so that I can pointedly speak with the homeowner(s). Also, should I be prevented from entering either 2259 23rd or 2181 23rd would you be able to sign an entry consent allowing me to use either of Buoyancy LLC parcels? EXHIBIT - 043 - PAGE - 001 ll� NJ 71 0) m 3 x 7!2, Ul C) rt W 0 W O C c !M 0 m0 -n 0 3 iTs- rt rt rT CL 0 0 0 0 N N rl,j N cn 44 3 rj rJ Nj Ni © 0 © 0 Fj rj rj N a W rn 0 _0 (D (D (1) n O o 0 -7 77 o n n M :3 0 0- (D Cl cu rt (D o --h 0 N- a :3 (D z 3 (D > -a 70 rt 0 rt W, C: to -0=-. n Ft. m !'au 0 D ;Q (D h NJ 0 0 N) U) n (D Z:z n 0 Ln c U) — (D 0 U) z (1) V) n 0' m C: 0 n n :3 tU (D 0- (D NJ 0 0 w Cf) 0 Ul C: (D r) Ln rt 6. (D EXHIBIT - 044 - PAGE - 001 Initial approval of impact glass EXHIBIT - 045 - PAGE - 001 Receipt Number: Transaction Number: Date Paid: Amount Due: Payment Details: Amount Paid: Change / Overage: Contact: FEE DETAILS: Fee Description Partial Inspection Reinspection Fee for Building Reinspection Fee for Building Partial Inspection Cashier Name: Batch Number: Entered By: Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT 20251358984 2025-083921 09/16/2025 $260.00 Payment Method Credit Card Amount Paid Check Number $260.00 4509098868 $260.00 $0.00 Kristen Jasinski 2805 Horseshoe Drive S Suite 10 Naples, FL 34104 Reference Number Original Fee PRAC20241042897 $65.00 PRAC20241042897 $65.00 PRAC20241042897 $65.00 PRAC20241042897 $65.00 cvmanager 14392 KarlOPabst Amount GL Account Paid $65.00 113-138900-322490 $65.00 113-138900-322490 $65.00 113-138900-322490 $65.00 113-138900-322490 EXHIBIT - 046 - PAGE - 001 Coll I*er Count Y_ CERTIFICATE OF COMPLETION This Certificate is issued pursuant to the requirements of the Florida Building Code, certifying that at the time of issuance this structure was in compliance with the various ordinances of the County regulating building construction for use for the following: Per FBC section 111.5, a certificate of completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system. This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a certificate of occupancy. Permit Number: PRWL20250938957 Permitted Address: 2225 23rd ST SW, Naples Owner BUOYANCY LLC Information: 2805 HORSESHOE DR S UNIT 10 NAPLES , FL 34104- Building Official: Fred Clum Business Name: Job Description: 4" Domestic Well Construction Ref-PRFH2O241041232 2225 23rd ST SW, Naples Number of Electrical Meters: Date Issued: September 24, 2025 Parcel: 45960240004 Fred Clum, Building Official The described portion of the structure has been inspected for compliance with the requirements of the FBC 8th Edition 2023 wl 2024 supl for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. For buildings and structures in flood hazard areas, documentation of the as -built lowest floor elevation has been provided and is retained in the records of the authority having jurisdiction. Note: A new certificate is required if the use of the building or premises is changed, or if alterations are made to the building or property described. A new certificate voids any certificate or prior date. Page 1 of 1 EXHIBIT - 047 - PAGE - 001 National Flood Insurance Program Ele,vati-.,.on e fica - ... �.. v rt, �� te, a 14-W, MRS, III E 2023 EDITION EXHIBIT - 048 - PAGE - 001 U.S. DEPARTMENT OF HOMELAND SECURITY OMB Control No. 1660.0008 Federal Emergency Management Agency Expiration Date: 06/30/2026 National Flood Insurance Program ELEVATION CERTIFICATE AND INSTRUCTIONS PAPERWORK REDUCTION ACT NOTICE Public reporting burden for this data collection is estimated to average 3.75 hours per response. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and submitting this form. You are not required to respond to this collection of information unless a valid OMB control number is displayed on this form, Send comments regarding the accuracy of the burden estimate and any suggestions for reducing the burden to: Information Collections Management, Department of Homeland Security, Federal Emergency Management Agency, 500 C Street SW, Washington, DC 20742, Paperwork Reduction Project (1660-0008). NOTE: Do not send your completed form to this address. PRIVACY ACT STATEMENT Authority: Title 44 CFR § 61.7 and 61.8. Principal Purpose(s): This information is being collected for the primary purpose of documenting compliance with National Flood Insurance Program (NFIP) floodplain management ordinances for new or substantially improved structures in designated Special Flood Hazard Areas. This form may also be used as an optional tool for a Letter of Map Amendment (LOMA), Conditional LOMA (CLOMA), Letter of Map Revision Based on Fill (LOMR-F), or Conditional LOMR-F (CLOMR-F), or for flood insurance rating purposes in any flood zone. Routine Use(s): The information on this form may be disclosed as generally permitted under 5 U.S.C. § 552a(b) of the Privacy Act of 1974, as amended. This includes using this information as necessary and authorized by the routine uses published in DHS/ FEMA-003 — National Flood Insurance Program Files System of Records Notice 79 Fed. Reg. 28747 (May 19, 2014) and upon written request, written consent, by agreement, or as required by law. Disclosure: The disclosure of information on this form is voluntary; however, failure to provide the information requested may impact the flood insurance premium through the NFIP. Information will only be released as permitted by law. PURPOSE OF THE ELEVATION CERTIFICATE The Elevation Certificate is an important administrative tool of the NFIP. It can be used to provide elevation information necessary to ensure compliance with community floodplain management ordinances, to inform the proper insurance premium, and to support a request for a LOMA, CLOMA, LOMR-F, or CLOMR-F, The Elevation Certificate is used to document floodplain management compliance for Post -Flood Insurance Rate Map (FIRM) buildings, which are buildings constructed after publication of the FIRM, located in flood Zones Al—A30, AE, AH, AO, A (with Base Flood Elevation (BFE)), VE, V1—V30, V (with BFE), AR, ARIA, AR/AE, AR/A1—A30, AR/AH, AR/AO, and A99. It may also be used to provide elevation information for Pre -FIRM buildings or buildings in any flood zone. As part of the agreement for making flood insurance available in a community, the NFIP requires the community to adopt floodplain management regulations that specify minimum requirements for reducing flood losses. One such requirement is for the community to obtain the elevation of the lowest floor (including basement) of all new and substantially improved buildings, and maintain a record of such information. The Elevation Certificate provides a way for a community to document compliance with the community's floodplain management ordinance. Use of this certificate does not provide a waiver of the flood insurance purchase requirement. Only a LOMA or LOMR-F from the Federal Emergency Management Agency (FEMA) can amend the FIRM and remove the federal mandate for a lending institution to require the purchase of flood insurance. However, the lending institution has the option of requiring flood insurance even if a LOMA/LOMR-F has been issued by FEMA. The Elevation Certificate may be used to support a LOMA, CLOMA, LOMR-F, or CLOMR-F request. Lowest Adjacent Grade (LAG) elevations certified by a land surveyor, engineer, or architect, as authorized by state law, will be required if the certificate is used to support a LOMA, CLOMA, LOMR-F, or CLOMR-F request. A LOMA, CLOMA, LOMR-F, or CLOMR-F request must be submitted with either a completed FEMA MT EZ or MT-1 application package, whichever is appropriate. If the certificate will only be completed to support a LOMA, CLOMA, LOMR-F, or CLOMR-F request, there is an option to document the certified LAG elevation on the Elevation Form included in the MT-EZ and MT-1 application This certificate is used only to certify building elevations. A separate certificate is required for floodproofing. Under the NFIP, non-residential buildings can be floodproofed up to or above the BFE. A floodproofed building is a building that has been designed and constructed to be watertight (substantially impermeable to floodwaters) below the BFE_ F000dproofing of residential buildings is not permitted under the NFIP unless FEMA has granted the community an exception for residential floodproofed basements. The community must adopt standards for design and construction of floodproofed basements before FEMA will grant a basement exception. For both floodproofed non-residential buildings and residential floodproofed basements in communities that have been granted an exception by FEMA, a floodproofing certificate is required. The expiration date on the form herein does not apply to certified and completed Elevation Certificates, as a completed Elevation Certificate does not expire, unless there is a physical change to the building that invalidates information in Section A Items A8 or A9, Section C, Section E, or Section H. In addition, this form is intended for the specific building referenced in Section A and is not invalidated by the transfer of building ownership. Additional guidance can be found in FEMA Publication 467-1, Floodplain Management Bulletin. Elevation Certificate. FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 1 of 8 EXHIBIT - 048 - PAGE - 002 U.S. DEPARTMENT OF HOMELAND SECURITY OMB Control No. 1660-0008 Federal Emergency Management Agency Expiration Date: 06/30/2026 National Flood Insurance Program ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 Copy all pages of this Elevation Certificate and all attachments for (11 community official (21 insurance a t/ d SECTION A - PROPERTY INFORMATION gen company, an (3) bullubly uwrtei. FOR INSURANCE COMPANY USE Al. Building Owner's Name: Jasinski Builders, LLC Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: Company NAIC Number: 2225 23rd Street S.W. City: Naples State: FL ZIP Code: 34117 A3. Property Description (e.g., Lot and Block Numbers or Legal Description) and/or Tax Parcel Number: Parcel ID #45960240004 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.): Accessory A5. Latitude/Longitude: Lat.26°11'19.37" Long.-81°39'12.42" Horiz. Datum: ❑ NAD 1927 ® NAD 1983 ❑ WGS 84 A6. Attach at least two and when possible four clear color photographs (one for each side) of the building (see Form pages 7 and 8). A7. Building Diagram Number: I A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s): N/A sq. ft. b) Is there at least one permanent flood opening on two different sides of each enclosed area? ❑ Yes ❑ No ® N/A c) Enter number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade: Non -engineered flood openings: N/A Engineered flood openings: N/A d) Total net open area of non -engineered flood openings in A8.c: N/A sq. in. e) Total rated area of engineered flood openings in A8.c (attach documentation - see Instructions): N/A sq. ft. f) Sum of A8.d and A8.e rated area (if applicable - see Instructions): N/A sq. ft. A9. For a building with an attached garage: a) Square footage of attached garage: N/A sq. ft. b) Is there at least one permanent flood opening on two different sides of the attached garage? 0 Yes ❑ No ® N/A c) Enter number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade: Non -engineered flood openings: N/A Engineered flood openings: N/A d) Total net open area of non -engineered flood openings in A9.c: N/A sq. in. e) Total rated area of engineered flood openings in A9.c (attach documentation - see Instructions): N/A sq. ft. t) Sum of A9.d and A9.e rated area (if applicable - see Instructions): N/A sq. ft. SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1.a. NFIP Community Name: Collier County Unincorporated Areas B1.b. NFIP Community Identification Number: 120067 B2. County Name: Collier County B3. State: FL B4. Map/Panel No.: 12021 C041 0 B5. Suffix: H B6. FIRM Index Date: 02/08/2024 B7. FIRM Panel Effective/Revised Date: 05/16/2012 B8. Flood Zone(s): AH B9. Base Flood Elevation(s) (BFE) (Zone AO, use Base Flood Depth): 12.0' B10. Indicate the source of the BFE data or Base Flood Depth entered in Item 69: ❑ FIS ® FIRM ❑ Community Determined ❑ Other. Bl 1. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? El Yes ® No Designation Date: ❑ CBRS ❑ OPA B13. Is the building located seaward of the Limit of Moderate Wave Action (LiMWA)? ❑ Yes ® No FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 2 of 8 EXHIBIT - 048 - PAGE - 003 I — ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAcaes 1.11 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. Policy Number: City: Naples State: FL ZIP Code: 34117 Company NAIC Number: SECTION C - BUILDING ELEVATIONINFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations —Zones Al A30, AE, AH, AO, A (with BFE), VE, V1 V30, V (with BFE), AR, ARIA, AR/AE, AR/A1—A30, AR/AH, AR/AO, A99. Complete Items C2.a—h below according to the Building Diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: GPS Vertical Datum: NAVD 88 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 N NAVD 1988 ❑ Other: Datum used for building elevations must be the same as that used for the BFE. Conversion factor used? ❑ Yes N No If Yes, describe the source of the conversion factor in the Section D Comments area. Check the measurement used: a) Top of bottom floor (including basement, crawlspace, or enclosure floor): 13.4 ® feet ❑ meters b) Top of the next higher floor (see Instructions): N/A ❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (see Instructions): N/A ❑ feet ❑ meters d) Attached garage (top of slab): N/A ❑ feet ❑ meters e) Lowest elevation of Machinery and Equipment (M&E) servicing the building (describe type of M&E and location in Section D Comments area): N/A ❑ feet ❑ meters f) Lowest Adjacent Grade (LAG) next to building: ❑ Natural ® Finished 12.8 N feet ❑ meters g) Highest Adjacent Grade (HAG) next to building: ❑ Natural N Finished 13.1 N feet ❑ meters h) Finished LAG at lowest elevation of attached deck or stairs, including structural support: N/A ❑ feet ❑ meters SECTION D. - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by state law to certify elevation information. l certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ® Yes ❑ No ❑ Check here if attachments and describe in the Comments area. Certifiier's Name: Peter D. Gratosky License Number: LS6985 •t ••GR,4����`,, Title: Owner ``������ ,�""� T � Company Name: Precision Land Surveyors, Inc. Q G�►e �+r�j 0 LS6985 °^ �;A V.., Address: 5126 Monza Court X City: Ave Maria State: FL ZIP Code: 34142 c L Telephone: (239) 910-339 Ext.: Email: p.gratosky@yahoo.com �°N STATE of Q = FLORIDA Signature: Date:10/06/2025 yi��la��`�•~� Copy all pages of this Elevation Certificate and all, achments for (1) community official, (2) insurance agent/company lafml(4)it)li�ing owner. Comments (including source of conversion factor in C2; type of equipment and location per C2.e; and description of any attachments): 1. The elevation of the well equipment is 13,4'. 2. The elevation of the crown of the road is 10.7'. FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 3 of 8 EXHIBIT - 048 - PAGE - 004 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRIICTlnNS nN InlcTs?I IrT1nti oncCc C 44 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. Policy Number: City: Naples State: FL ZIP Code: 34117 Company NAIC Number: SECTION E — BUILDING MEASUREMENT INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO, ZONE ARIAO, AND ZONE A (WITHOUT BFE). For Zones AO, AR/AO, and A (without BFE), complete Items E1—E5. For Items El—E4, use natural grade, if available. If the Certificate is intended to support a Letter of Map Change request, complete Sections A, B, and C. Check the measurement used. In Puerto Rico only, enter meters. Building measurements are based on: Construction Drawings" ❑ Building Under Construction' Finished Construction `A new Elevation Certificate will be required when construction of the building is complete. El. Provide measurements (C.2.a in applicable Building Diagram) for the following and check the appropriate boxes to show whether the measurement is above or below the natural HAG and the LAG. a) Top of bottom floor (including basement, crawlspace, or enclosure) is: ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is: ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (C2.b in applicable Building Diagram) of the building is: ❑ feet ❑ meters ❑ above cr ❑ below the HAG. E3. Attached garage (top of slab) is: ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is: ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S AUTHORIZED REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge ❑ Check here if attachments and describe in the Comments area. Property Owner or Owner's Authorized Representative Name: Address: City: State: ZIP Code: Telephone: Ext.: Email: Signature: Date: Comments: FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 4 of 8 EXHIBIT - 048 - PAGE - 005 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS nN INSTRLICTInM oe ra-Gc 4_44 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. Policy Number: City: Naples State: FL ZIP Code: 34117 Company NAIC Number: SECTION G — COMMUNITY INFORMATION .(RECOMMENDED FOR COMMUNITY OFFICIAL COMPLETION) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Section A, B, C, E, G, or H of this Elevation Certificate. Complete the applicable item(s) and sign below when: G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by state law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2.a. ❑ A local official completed Section E for a building located in Zone A (without a BFE), Zone AO, or Zone AR/AO, or when item E5 is completed for a building located in Zone AO. G2.b. ❑ A local official completed Section H for insurance purposes. G3. ❑ In the Comments area of Section G, the local official describes specific corrections to the information in Sections A B, E and H. G4. ❑ The following information (Items G5—G11) is provided for community floodplain management purposes. G5. Permit Number: G6. Date Permit Issued: G7. Date Certificate of Compliance/Occupancy Issued: G8. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G9.a. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum: G9.b. Elevation of bottom of as -built lowest horizontal structural member: ❑ feet ❑ meters Datum: G10.a. BFE (or depth in Zone AO) of flooding at the building site: ❑ feet ❑ meters Datum: G10.b. Community's minimum elevation (or depth in Zone AO) requirement for the lowest floor or lowest horizontal structural member: ❑ feet ❑ meters Datum: G11. Variance issued? ❑ Yes ❑ No If yes, attach documentation and describe in the Comments area. The local official who provides information in Section G must sign here. I have completed the information in Section G and certify that it is correct to the best of my knowledge. If applicable, I have also provided specific corrections in the Comments area of this section. Local Official's Name: Title: NFIP Community Name: Telephone: Ext.: Email: Address: City. State: ZIP Code: Signature: Date: Comments (including type of equipment and location, per C2.e; description of any attachments; and corrections to specific information in Sections A, B, D, E, or H). rtmH rorm rr-zuti-F Y-22-152 (formerly 086-0-33) (8123) Form Page 5 of 8 EXHIBIT - 048 - PAGE - 006 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRI IrTION oecGc 4-44 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. Policy Number: City: Naples State: FL ZIP Code: 34117 Company NAIC Number: SECTION H — BUILDING'S FIRST FLOOR HEIGHT INFORMATION FOR ALL ZONES (SURVEY NOT REQUIRED) (FOR INSURANCE PURPOSES ONLY) The property owner, owner's authorized representative, or local floodplain management official may complete Section H for all flood zones to determine the building's first floor height for insurance purposes. Sections A, B, and I must also be completed. Enter heights to the nearest tenth of a foot (nearest tenth of a meter in Puerto Rico). Reference the Foundation Type Diagrams (at the end of Section H Instructions) and the appropriate Building Diagrams (at the end of Section I Instructions) to complete this section. H1. Provide the height of the top of the floor (as indicated in Foundation Type Diagrams) above the Lowest Adjacent Grade (LAG): a) For Building Diagrams 1A, 1B, 3, and 5-8. Top of bottom ❑ feet ❑ meters ❑ above the LAG floor (include above -grade floors only for buildings with crawlspaces or enclosure floors) is: b) For Building Diagrams 2A, 2B, 4, and 6-9. Top of next ❑ feet ❑ meters ❑ above the LAG higher floor (i.e., the floor above basement, crawlspace, or enclosure floor) is: H2. Is all Machinery and Equipment servicing the building (as listed in Item H2 instructions) elevated to or above the floor indicated by the H2 arrow (shown in the Foundation Type Diagrams at end of Section H instructions) for the appropriate Building Diagram? ❑ Yes ❑ No SECTION I — PROPERTY OWNER (OR OWNER'S AUTHORIZED REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and H must sign here. The statements in Sections A, B, and H are correct to the best of my knowledge. Note: If the local floodpiain management official completed Section H, they should indicate in Item G2.b and sign Section G. ❑ Check here if attachments are provided (including required photos) and describe each attachment in the Comments area. Property Owner or Owner's Authorized Representative Name: Address: City: State: ZIP Code: Telephone: Ext.: Email: Signature: Date: Comments: FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 6 of 8 EXHIBIT - 048 - PAGE - 007 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS See Instructions for Item A6. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. Policy Number: City: Naples State: FL ZIP Code: 34117 Company NAIC Number: Instructions: Insert below at least two and when possible four photographs showing each side of the building (for example, may only be able to take front and back pictures of townhouses/rowhouses). Identify all photographs with the date taken and "Front View," "Rear View," "Right Side View," or "Left Side View." Photographs must show the foundation. When flood openings are present, include at least one close-up photograph of representative flood openings or vents, as indicated in Sections A8 and A9. i �1NiS Photo One Photo One Caption: FRONT VIEW Clear Photo One a c ges Photo Two Photo Two Caption: LEFT SIDE VIEW Photo Clear Two FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8123) Form Page 7 of 8 EXHIBIT - 048 - PAGE - 008 ELEVATION CERTIFICATE IMPORTANT: MUST FOLLOW THE INSTRUCTIONS ON INSTRUCTION PAGES 1-11 BUILDING PHOTOGRAPHS Continuation Page Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.: FOR INSURANCE COMPANY USE 2225 23rd Street S.W. City: Naples State: FL ZIP Code: 34117 Policy Number: Company NAIC Number: Insert the third and fourth photographs below. Identify all photographs with the date taken and "Front View," "Rear View," "Right Side View," or "Left Side View." When flood openings are present, include at least one close-up of representative flood photograph openings or vents, as indicated in Sections A8 and A9. c1, # NK t x r u+iY{J �S ♦ I � A ♦ 1 Photo Three Photo Three Caption: REAR VIEW Clear Photo'Three y f h_ 0 ♦ 1 ♦ i Photo Four Photo Four Caption: RIGHT SIDE VIEW Clear Photo Four FEMA Form FF-206-FY-22-152 (formerly 086-0-33) (8/23) Form Page 8 of 8 EXHIBIT - 048 - PAGE - 009 L l M VOlaOld 'S3ldVN d412iO1� 'S3�d dN MS.LS Ob£z 9zzz BSnOH -113M w MS 1S a?A£Z SZZZ w O �r J W : O N N N r C� 0 Q. 0 LL v) LLJ Q Z L VJ CW C U 0 Z 0 N� L.L Z 0 U W Z W Z z 0 Q Q J J W a xz0 opw�- 96i z�I s^3WZVJ u = w 3 W W z.oa�oo Q0ozz Woo .000UU w CL (L QQ Q(n fnN C/) Z Q _ ���� :D _ J Q U N Q W w 3 L a "a Q a ITL Lu LLs aLLLLa o _ 2 S,_ w In O 0 z a. O O O 0 0: 4 F; o � o � N m i z � w w co W CN O <� o 0 e EXHIBIT - 048 - PAGE - 010 `d412JOlJ 'SElddN ���bsvaiao��'s3�ddN w MS is O2!£z szzz 3snOH -11�]nn h = x 0-1-1 'AONdAOnB Ms is chlez OZZZ Jueuanod ,Jo e6P3 T-- U ti O U 3 V' e I N } uj LD U O J C y N I M LO a LO a I ryjl4 O O I I O � I M0738 77V130 33Sp�j a�Uomsab '00is au0 6 vss,, 3 1 I W Cn - % Ms Z O ,08° I - w,x __j w CO O N p'I ❑ a P1013 Wol0 W �1 '' u O p Q h - �'- ° `N a Z O � a.r --�- a Ee U CO `ate ° u c � iz - � Cn I� —g �y Z O a P Lo O a `� ly- V OLL to w o ca 8< <9zs z p LU gz .011 M „ 01, 61.00 S 6��d"I o NOb9L ,0£ OF yb� Lo F o Qv i N M N N U (n U C U �-- M N y •p ONi � L O N ^ I U raj 4�7 J O a m 3 o h _00'OLZ o ODUDJ 6UNSix3) o 4UacuaSo3 95OUIDA9 ,5S ,00.0££ 3 „01,0..00 N EXHIBIT -048- PAGE -011 Lt lK VO'do-H 'S3ldbN dd 1HOld 'S3ldHN o nnslsaaerszzz DsnoH 113M N a � `A:DNv),on8 r Q a? MS 1S �EZ SZZZ R • I (===3=1 r • a EXHIBIT - 048 - PAGE - 012 COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DEPARTMENT BUSINESS CENTER 2800 N. Horseshoe Drive, Naples FL 34104 I Phone (239) 252-2400 Initial Incomplete Notice Incomplete Revision Submittal Notice October 08, 2025 Kristen Jasinski RE: Permit Number: PRAC20241042897 Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. REV 1: Submitting Truss Plans REV02- Change in specified window and doors. Difference between what was specified originally and what has been installed. 2225 23rd ST SW, Naples Job Address: 2225 23rd ST SW, Naples A sufficiency review of the submittal package for the above referenced application has been deemed insufficient. Failure to respond to this notice within 10-business days will result in this permit application being set to a "Denied" status and will be considered closed. A new permit submittal will be required before proceeding with the proposed work. The following items will need to be submitted so that we may continue to process your application. - Reviewed By: Irma Jimenez Phone: (239) 252-1204 Email: Irma.Jimenez@Collier.Gov 1. Revision Documents - Two index sheets with different information were provided. Please clarify or re upload the correct one. For electronic submissions, outstanding documents can be submitted online. You will need to click on the "Submittals" button near the bottom of the page to upload to each submittal requirement. Your application can be accessed here: https://cv,portal.coIIiercountyfl.gov/Ci!yViewWeb/ EXHIBIT - 049 - PAGE - 001 ,ore. r,s....,, RE: PRAC20241042897 - 154 inspection 1 message Tonya Chancy <Tonya.Chancy@collier.gov> To: Kristen Jasinski <kristen@jasinskibuilders.com> Kristen Jasinski <kristen@naplesfloridavacationhomes.com> You can reach out to the Structural Chief, Myron Jacobs regarding the inspection below. Myron.Jacobs@collier.gov Or call 239-252-2427 Thank you, Tonya Tonya Chancy Planning & Permitting Technician I Building Plan Review & Inspection Office:239-252-2914 2400 N Horseshoe Dr Naples, FL 34104 Tonya.Chancy@collier.gov My email address has changed. Effective immediately, please update your contact list to use this new address: Tonya.Chancy@collier.gov From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Friday, October 17, 2025 9:02 AM To: Inspections <Inspections@collier.gov> Subject: PRAC20241042897 - 154 inspection Fri, Oct 17, 2025 at 11:20 AM 4 Collier County 0@0(0@ EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Hello, With reference to accessory structure at 2225 23rd Street SW, 154 soffit in progress inspection is still showing up as pending and can be scheduled. On 8/13 Gregory Moff failed this inspection as the work was not yet ready to be inspected. Thereafter, on 8/15 Karl Pabst inspected and passed the inspection. Can you please adjust the system so it reflects this inspection was completed and is no longer pending? Thanks for your help. Regards, EXHIBIT - 050 - PAGE - 001 Kristen Jasinski Certified Residential Building Contractor # CRC1333281 Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com Under Florida Law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. EXHIBIT - 050 - PAGE - 002 Various correspondences, meetings, text messages, and attempts from Client to County relating why there are outstanding requests for duplicate inspections of soffit covering (already passed on August 13, 2025)s in progress and impact glass (already passed on September 16, 2025) EXHIBIT - 051 - PAGE - 001 Collier County Payment Slip - Permits Date: October 20, 2025 Contact: Kristen Jasinski 2805 Horseshoe Drive S, #10 Naples, FL 34104 Owner: BUOYANCY LLC Contractor: JASINSKI BUILDERS, LLC Permit Location: 2225 23rd ST SW, Naples Job Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. REV 1: Submitting Truss Plans REV02- Change in specified window and doors. Difference between what was specified originally and what has been installed. 2225 23rd ST SW, Naples FEES: Description pplication Number lRermit Number Eeej Paid Fee Revision PRAC20241042897 IPRAC2024104289703 $50.00 $0.00 Total: $50.00 $0.00 Bonds: Item Tvpe Balance The following conditions must be satisfied before your permit can be issued: The following conditions must be satisfied before you can call your first inspection: > Revision Inspection Hold. This condition will be resolved once the revision has been issued. You can track your permit using the following link: https://cvportal.col I iercou ntyfl. gov/C ityViewWeb//Permit/StatusReference?referenceN umber=PRAC20241042897 To pay online use the following link: https: //cvl2ortal.colliercountyfl.00v/CityViewWeb/ Must be a GMD Public Portal registered user to make payment. EXHIBIT - 052 - PAGE - 001 Receipt Number: Transaction Number: Date Paid: Amount Due: Payment Details: Amount Paid: Change / Overage: Contact: FEE DETAILS: Fee Description Revision Cashier Name: Batch Number: Entered By: Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT 20251370148 2025-095085 10/20/2025 $50.00 Payment Method Amount Paid Check Number Credit Card $50.00 4571225730 $50.00 $0.00 Kristen Jasinski 2805 horseshoe drive s, suite 10 Naples, FL 34104 Reference Number Original Fee PRAC20241042897 $50.00 cvmanager 14472 Elizabeth. Rosales Amount GL Account Paid $50.00 1013-138900-322110-000000 EXHIBIT - 053 - PAGE - 001 ^"""'""' Kristen Jasinski <kristen@naplesfioridavacationhomes.com> VROAVOR RONIM PRAC20241042897 - 2225 23rd Street SW - Inspections 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Mon, Oct 27, 2025 at 12:07 PM To: myron.jacobs@collier.gov Cc: inspections@colliercountyfl.gov, inspections@collier.gov Myron, 10 days ago I sent an email to Inspections@colliercountyfl.gov and never received a response. I recognize the County has a new format for email addresses. It seems every has transitioned to XXX@Collier.gov. I'm not certain if the old emails of XXX@colliercountyfl.gov are still working. From the main phone number, 239-252-2400 and select the options for Inspections, the message says to leave a message or send an email to inspections@co[iiercountyfl.gov. I have also left at least two voice mails over the past 10 days and have never received a response. Next, with respect to PRAC20241042897 the accessory structure at 2225 23rd Street SW, the portal still shows 2 pending inspections for Impact glass and Soffit Coverings in Progress. These inspections were both passed in mid - August and mid -September. At some point I did submit a revision to change the window type from an awning window to a horizontal slider. When the inspection took place, the horizontal slider (type I changed it to) was in place. Your assistance to clear up this will be appreciated as I look to close this permit out very soon. Thank you Myron. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 ��BU I LD E RS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com EXHIBIT - 054 - PAGE - 001 YA 1-1. Kristen Jasinski <kristen@naplesfloridavacationhomes.com> RE: PRAC20241042897 - 2225 23rd Street SW - Inspections 1 message Tonya Chancy <Tonya.Chancy@collier.gov> Mon, Oct 27, 2025 at 1:55 PM To: Kristen Jasinski <kristen@jasinskibuilders.com>, Myron Jacobs <Myron.Jacobs@collier.gov> Hi, The permit number listed above is in the inspections commenced at this time. There are two inspections that are still pending 802 Landscaping 10/28/25is the date it is schedule for inspection. 115 Building Final 10/29/25 is the date this inspection is schedule for as well. I am not sure what you are asking. If you are wanting the permit closed once the status of the permit goes to "Inspections Completed" You can always email me back and I will take a look to see if all fees and condition are resolved then close the permit for you. Thank you, Tonya "'— Tonya Chancy Planning & Permitting Technician Building Plan Review & Inspection Office:239-252-2914 2400 N Horseshoe Dr Naples, FL 34104 Tonya.Chancy@collier.gov My email address has changed. Effective immediately, please update your contact list to use this new address: Tonya.Chancy@collier.gov From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Monday, October 27, 2025 12:08 PM To: Myron Jacobs <Myron.Jacobs@collier.gov> Cc: Inspections <Inspections@collier.gov>; Inspections <Inspections@collier.gov> Subject: PRAC20241042897 - 2225 23rd Street SW - Inspections —t Collier County Em ��W\(0M EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Myron, 10 days ago I sent an email to Inspections@colliercountyfl.gov and never received a response. I recognize the County has a new format for email addresses. It seems every has transitioned to X)(X@Collier.gov. I'm not certain if the old emails of XXX@colliercountyfl.gov are still working. EXHIBIT - 055 - PAGE - 001 Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Y$C lt?Et RE: PRAC20241042897 - 2225 23rd Street SW - Inspections 1 message Myron Jacobs <Myron.Jacobs@collier.gov> To: Kristen Jasinski <kristen@jasinskibuilders.com> Cc: Inspections <Inspections@collier.gov> Good afternoon Kirsten, Tue, Oct 28, 2025 at 12:38 PM The only inspection pending is the 115 Building Final which is scheduled for tomorrow Wednesday October 29, 2025 Myron Jacobs Chief Building Inspector Building Plan Review & Inspection Office:239-252-2427 2400 N Horseshoe Dr Naples, FL 34104 Myron.Jacobs@collier.gov My email address has changed. Effective immediately, please update your contact list to use this new address: Myron.Jacobs@collier.gov From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Monday, October 27, 2025 12:08 PM To: Myron Jacobs <Myron.Jacobs@collier.gov> Cc: Inspections <Inspections@collier.gov>; Inspections <Inspections@collier.gov> Subject: PRAC20241042897 - 2225 23rd Street SW - Inspections -C Collier County 0@000 EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Myron, 10 days ago I sent an email to Inspections@colliercountyfl.gov and never received a response. I recognize the County has a new format for email addresses. It seems every has transitioned to XXX@Collier.gov. I'm not certain if the old emails of XXX@colliercountyfl.gov are still working. From the main phone number, 239-252-2400 and select the options for Inspections, the message says to leave a message or send an email to inspections@colliercountyfl.gov. I have also left at least two voice mails over the past 10 days and have never received a response. Next, with respect to PRAC20241042897 the accessory structure at 2225 23rd Street SW, the portal still shows 2 pending inspections for Impact glass and Soffit Coverings in Progress. These inspections were both passed in mid -August and mid -September. EXHIBIT - 055 - PAGE - 002 Kristen Jasinski <kristen@naplesfioridavacationhomes.com> FRCA�xou . Status - Well House at 2225 23rd Street SW - CESD2024O0O1061 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Thu, Oct 30, 2025 at 9:57 PM To: Bradley Holmes <bradley.holmes@colliercountyfl.gov> Hello Bradley, Please be advised that the original well house at 2225 23rd Street SW which was the subject of the above reference Code Enforcement case has been fully demolished. We have completed all of the respective inspections and other requirements under permit #PRDM20241042895. At next week's hearing with the Magistrate I would like to request that the accrued fines be reduced or eliminated. Can you provide instructions as to what needs to be done to make that request? I do have aerial photo evidence that the well house existed when the house when the house received it's original certificate of occupancy in 2000. Thank you for any guidance you can provide. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 ���B JILDERS� Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com IMG_3563.jpeg 6624K EXHIBIT - 056 - PAGE - 001 0 Collier County CERTIFICATE OF COMPLETION This Certificate is issued pursuant to the requirements of the Florida Building Code, certifying that at the time of issuance this structure was in compliance with the various ordinances of the County regulating building construction for use for the following: Per FBC section 111.5, a certificate of completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system. This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a certificate of occupancy. Permit Number: PRDM20241042895 Permitted Address: 2225 23rd ST SW, Naples Owner BUOYANCY LLC Information: 2805 HORSESHOE DR S UNIT 10 NAPLES , FL 34104- Building Official: Fred Clum Business Name: Job Description: Demolish old unpermitted well house. 2225 23rd ST SW, Naples Number of Electrical Meters: Date Issued: October 31, 2025 Parcel: 45960240004 .14 Fred slum, Building Official The described portion of the structure has been inspected for compliance with the requirements of the FBC 8th Edition 2023 w/ 2024 sup1 for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. For buildings and structures in flood hazard areas, documentation of the as -built lowest floor elevation has been provided and is retained in the records of the authority having jurisdiction. Note: A new certificate is required if the use of the building or premises is changed, or if alterations are made to the building or property described. A new certificate voids any certificate or prior date. Page 1 of 1 EXHIBIT - 057 - PAGE - 001 Kristen Jasinski <kristen@naplesfloridavacationhomes.com> p1fQA4'�OA RE: Status - Well House at 2225 23rd Street SW - CESD20240001061 1 message Bradley Holmes <Bradley.Holmes@collier.gov> Fri, Oct 31, 2025 at 7:39AM To: Kristen Jasinski <kristen@jasinskibuilders.com> Hello Kristen, Thank you for your email. I am glad to hear this has been resolved. I have updated the code case and generated the affidavit of compliance. This document is submitted to our legal team who will then process to have the case scheduled for an Imposition of Fines hearing. At that hearing, you will have the opportunity to request waiver or reduction of the fine amount. *1 do not have a date certain for the scheduling of this hearing* Ahead of that hearing, please ensure the operational costs from the last hearing have been paid — see below. Any evidence you feel supports your request for waiver or reduction should be brought with you. If you have it in digital format, you may provide it to me via email. I will add it to the case folder and I will open the document(s) at your direction while you are speaking with the Magistrate. EXHIBIT - 058 - PAGE - 001 �- Collier County CERTIFICATE OF COMPLETION This Certificate is issued pursuant to the requirements of the Florida Building Code, certifying that at the time of issuance this structure was in compliance with the various ordinances of the County regulating building construction for use for the following: Per FBC section 111.5, a certificate of completion is proof that a structure or system is complete and for certain types of permits is released for use and may be connected to a utility system. This certificate does not grant authority to occupy a building, such as shell building, prior to the issuance of a certificate of occupancy. Permit Number: PRAC20241042897 Permitted Address: 2225 23rd ST SW, Naples Owner BUOYANCY LLC Information: 2805 HORSESHOE DR S UNIT 10 NAPLES , FL 34104- Building Official: Fred Clum Business Name: Date Issued: November 05, 2025 Parcel: 45960240004 Job Description: Construct new well house in new location. Move all existing equipment to new well house. This permit accompanies permit application PRFH2O241041232 which includes new electrical to the new well house. PRDM20241042895 has also been made to demolish the old well house once the new well house has been completed. .�, REV 1: Submitting Truss Plans REV02- Change in specified window and doors. Difference between what was specified originally and what has been installed. 2225 23rd ST SW, Naples Number of Electrical Meters: 0 Fred Clum, Building Official The described portion of the structure has been inspected for compliance with the requirements of the FBC 8th Edition 2023 w/ 2024 supl for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. For buildings and structures in flood hazard areas, documentation of the as -built lowest floor elevation N. has been provided and is retained in the records of the authority having jurisdiction. Note: A new certificate is required if the use of the building or premises is changed, or if alterations are made to the building or property described. A new certificate voids any certificate or prior date. Page 1 of 1 EXHIBIT - 059 - PAGE - 001 pA0$470A Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Re: Over charged for Inspection Fees PRAC20241042897 - 2225 23rd Street SW Accessory Structure 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Thu, Nov 6, 2025 at 7:39 AM To: Miranda Paredes <Miranda.Paredes@collier.gov> Miranda, Thank you for your help to finally get these extra inspection fees taken care of. Earlier in an email to Myron I mentioned that when you get the voice mail in the inspections department, the voice message invites you to email to inspections@colliercountyfl.gov. If the redirect is set to expire, then the voice mail prompts should be updated to the new email address ending in collier.gov. Myron certainly has many demands on his time so I thought I would share this with you. Perhaps you are able to communicate this to the right people. I tried calling to check but because it was before opening time I only got a message saying you were closed and to call back. Would be nice if the after hours phone system would at least allow the people you serve to reach the appropriate department to leave a message which of course could be attended to once the department reopened. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 da 5414 T� BZIILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com On Tue, Nov 4, 2025 at 19:42 Miranda Paredes <Miranda.Paredes@collier.gov> wrote: Kristen, Per the Building Manager, the fee has been removed. Miranda Paredes Operations Support Specialist I Building Plan Review & Inspection Office: 239-2 52-2713 2800 Horseshoe Drive North Naples, Florida 34104 Miranda. Paredes@collier.gov My email address has changed. Effective immediately, please update your contact list to use this new address: Miranda. Paredes@collier.gov ~ From: Miranda Paredes <Miranda.Paredes@collier.gov> Sent: Tuesday, November 4, 2025 3:00 PM EXHIBIT - 060 - PAGE - 001 VOCATION Kristen Jasinski <kristen@naplesfloridavacationhomes.com> Re: Status - Well House at 2225 23rd Street SW - CESD20240001061 1 message Kristen Jasinski <kristen@jasinskibuilders.com> Thu, Nov 6, 2025 at 9:33 PM To: Bradley Holmes <Bradley.Holmes@collier.gov> Bradley, Attached are files which I would like to share with the Magistrate with respect to our request to have fees reduced. Given the file size I will send in a couple of emails. Regards, Kristen Jasinski Certified Residential Building Contractor# CRC1333281 IF f �BCIILDERS Jasinski Builders, LLC 2805 Horseshoe Drive S, #10 Naples, FL 34104 239-296-8800 Kristen@JasinskiBuilders.com On Fri, Oct 31, 2025 at 7:39AM Bradley Holmes <Bradley.Holmes@collier.gov> wrote: Hello Kristen, Thank you for your email. I am glad to hear this has been resolved. I have updated the code case and generated the affidavit of compliance. This document is submitted to our legal team who will then process to have the case scheduled for an Imposition of Fines hearing. At that hearing, you will have the opportunity to request waiver or reduction of the fine amount. *1 do not have a date certain for the scheduling of this hearing* Ahead of that hearing, please ensure the operational costs from the last hearing have been paid — see below. Any evidence you feel supports your request for waiver or reduction should be brought with you. If you have it in digital format, you may provide it to me via email. I will add it to the case folder and I will open the document(s) at your direction while you are speaking with the Magistrate. EXHIBIT - 061 - PAGE - 001 Collier Blvd Nagle DEROM Naples, FL 34119 Bradley. Holmes@collier.gov My email address has changed. Effective immediately, please update your contact list to use this new address: Bradley.Holmes@collier.gov From: Kristen Jasinski <kristen@jasinskibuilders.com> Sent: Monday, December 1, 2025 08:00 To: Bradley Holmes <Bradley.Holmes@collier.gov> Cc: Jeffrey Letourneau <Jeffrey.Letourneau@collier.gov> Subject: Follow up to Code Enforcement Cases - 2225 23rd Street SW EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. RE: CESD20240001061 (Pump house) & CESD20240001058 (Main House Hello Bradley, I hope you had a pleasant Thanksgiving. As you know the pump house was demolished and the permit pertaining to it has been fully closed. There are accrued fines which we need to ask the Special Magistrate to reduce or eliminate. Also with respect to the main house, we have completed all inspections except for the 503 Electrical Service Change and 172 Residential Remodeling Building Final. 522 Final Electrical is only pending completion of the service upgrade. This delayed is caused by continual delays from the manufacturerABB / GE of the MDP Panel. Though we ordered this specialty panel back in early August within weeks of getting the permit approved, the manufacturer keeps pushing back the due date. This week our ship date of November 27th changed yet again to December 16th. It will be shipping from Mexico so we expect to receive it shortly after Christmas. Of course our electricians stand ready to wrap up this service upgrade once they receive the equipment and then it will be for FPL to finalize the service upgrade. This service upgrade is new work which was permitted together with the after -the -fact work. There are accrued fines on both Code Enforcement matters which we need to ask the Special Magistrate to reduce or eliminate. My challenge is that I have to leave the country in January for an extended period of time to seek medical care for my daughter with special needs. It makes it very difficult to make plans for that when I have no idea when I will be given a hearing date before the Special Magistrate to reconsider the accrued fines. The fines began accruing simply for the fact that we overlooked the need to go back to the magistrate and ask for additional time. All the while we actively working hard to pursue the after -the -fact permit, always responding very quickly to any requests the plan reviewer made. Can we possibly get a hearing before the Magistrate or have him reconsider the accrued fines outside of the monthly hearing dates? Please advise. Regards, Kristen Jasinski Certified Residential Building Contractor # CRC1333281 EXHIBIT - 062 - PAGE - 001 Date Vendor Description Amount 5/19/2024 Davis Duke PLLC business expense 11 - Expense Category: Professional Fees 4 - Notes: Legal fee 1,794.69 6/2412024 Department Collier County Building Department 223.40 6/24/2024 Department Code enforcement fee 49.00 612412024 Department Code enforcement hearing 223,40 7/1/2024 Archterior Brian Palkovic Architect Palkovic - Knickerbocker 1,840.00 7/22/2024 Department Paymentus 0.50 7/22/2024 Department Paymentus 0.50 7/22/2024 Department Collier County Building Department 111.90 7/22/2024 Department Collier County Building Department 200.00 7/22/2024 Davis Duke PLLC Davies Duke: Code enforcement legal fees 2,802.00 7/22/2024 Davis Duke PLLC Davies Duke: Code enforcement legal fees 2,802.00 7/29/2024 Archterior Drafting for $1,880.00 8/7/2024 Cronin Engineering Cronin Engineering: Engineering Drawings $7,000.00 8/23/2024 Davis Duke PLLC 15 BOOK TRANSFER DEBIT ACH Davies Duke 395.00 9/24/2024 Midwest Reprographics Midwest printing and signs $8.44 10/3/2024 Archterior Palkovic Payment to Palkovic - Archterior design $480.00 10/15/2024 Collier County Clerk Notice of Commencement recording $10.35 10/16/2024 Cronin Engineering Payment to Cronin Engineering $8,000.00 10/18/2024 Midwest Reprographics Midwest Printing & Signs: Scanning $12.59 10/29/2024 Collier County Building Departr Permit application fee for main house $52.17 10/29/2024 Collier County Building Departr service fee for well house $245.79 11/13/2024 Collier County Building Departr permit application $103.10 11/21/2024 ResCalcs Energy Calculations $1,200.00 11/27/2024 Naples Lumber Purchase of lumber $425.00 12/5/2024 Archterior Drafting Payment to Archterior Palkovic $880.00 12/31/2024 Journal Entry To capitalize major repairs & code enforcement upgrades 26.697.44 12/31/2024 Journal Entry To capitalize legal expenses for code enforcement upgrades 16,697.44 12/31/2024 Journal Entry To capitalize major repairs & code enforcement upgrades 10,000.00 2/4/2025 Midwest Reprographics Payment to Midwest Printing $37.41 2/11/2025 Plumbing Contractor Plumb Crazy Contracting LLC: Payment $1,167.89 3/31 /2025 Archterior Design Archterior Design 885 4/24/2025 DP Water Well / water equipment 1150 6/2812025 Midwest Printing & Signs, LLC Knickerbocker 2225 23rd Street SW 11 - Expense Category: Construction Materials 4 • 16,88 7/31/2025 Home Depot Card: Physical 1 Budget: WKJ Holdings I Merchant Address: NAPLES, FL 34112 1 -121.90 8/17/2025 Sherwin Williams Knickerbocker 2225 23rd Street SW 11 - Expense Category: Construction Materials 4 96.61 911012025 BankofAmerica Tranxns permit fee for main house (includes $129.06 pmt processing fee) 4,292.19 9/1 D12O25 BankofAmerica Tranxns Deposit on electrical upgrade at 2225 23rd Street SW 16,024.45 9/10/2025 American Exp tranxns Payment for wire and conduit from house to FPL Pole 9,669.98 911012025 American Exp tranxns Roof tile materials 1,089.37 9/10/2025 American Exp tranxns Private Provider Inspection Deposit 2,675.00 9/10/2025 American Exp tranxns Materials from Naples Lumber 1,252.53 9/1012025 American Exp tranxns Exotic plant clean up and trench for service upgrade 3,400.00 9/10/2025 American Exp tranxns Precision Land Surveyors 1,400.00 9/10/2025 American Exp tranxns Payment to Graybar Electric 1,400.00 9/15/2025 Materials from Naples Lumber 2,390.00 9/16/2025 David Spiesman electrician 2,500.00 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job I Address 1 Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings j Merchant Address: NAPLES, FL 9/17/2025 Home Depot 341090000 51.91 The Sherwin-Williams Comp User: Kristen Jasinski 12 - Job / Address I Class 2225 23rd St SW I 1 - Expense Category: Construction Materials 14 - Notes: Paint I Card: 9/17/2025 Sherwin Williams Physical I Budget: WKJ Holdings I Merchant Address: 800-4743794, OH 44115 520.33 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job I Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None j Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 9/17/2025 Home Depot 341090000 47.49 THE HOME DEPOT #6348 User: Dumitru Ceban 12 - Job I Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to: None I Card: Physical I Budget: WKJ Holdings 1 Merchant Address: NAPLES, FL 9118/2025 Home Depot 341120000 26.50 The Sherwin-Williams Comp User: Kristen Jasinski 12 - Job / Address / Class: 2225 23rd St SW 11 - Expense Category: Construction Materials 4 - Notes: Misc interior paints j Card: Physical 1 Budget: WKJ Holdings I Merchant Address: 800-4743794, OH 9/19/2025 Sherwin Williams 44115 236.22 9/23/2025 ABC Supply ABC SUPPLY/BT0922 XXXXXXXX5914311 Naples Florida Vacatio 1,201.99 EXHIBIT - 106 - PAGE - 001 EXHIBIT - 063 - PAGE - 001 9/24/2025 Jimenez Well Drilling, Inc. JIMENE7_ WELL DRI/SALE NAPLES FLORIDA VACATIO 3,800.00 SUNSHINE ACE -GOLDEN GAT User: Dumitru Ceban 12 - Job 1 Address / Class: Knickerbocker 2225 23rd Street SW I 1 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 9/2412025 Sunshine Ace Hardware 34116 39.33 SHERWIN-WILLIAMS702002 User: Kristen Jasinski 12 - Job / Address / Class: 2225 23rd St SW 11 - Expense Category: Construction Materials ( Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 34103 1 Cleared Time in Statement 9/24/2025 Sherwin Williams (MT): 2025-09-24 14:31-54 169.52 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job I Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: JB Customer I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 9/25/2025 Home Depot 341090000 142.04 GRAYBAR ELECTRIC COMPANY User: Kristen Jasinski 12 - Job I Address / Class. 2225 23rd St SW 11 - Expense Category: Construction Materials Card: Physical 9/28/2025 Graybar Electric Budget: WKJ Holdings I Merchant Address: SAINT LOUIS, MO 63105 101.82 9129/2025 Golden Gate Electric ACH MKE Prefunding ACH Offset 250930 XXXXXX2879 17,319.29 DP WATER TREATMENT, 9/30/2025 LLC. DP WATER TREATME/SALE NAPLES FLORIDA VACATIO 10,221.41 9/30/2025 Christopher Hall ACH MKE Prefunding ACH Offset 251003 XXXXXX2879 5,495,67 SHERWIN-WILLIAMS702002 User: Kristen Jasinski 12 - Job / Address I Class: 2225 23rd St SW 11 - Expense Category: Materials 14 - Notes: Interior paint and primer for well house I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/2/2025 Sherwin Williams 34103 257.43 The Sherwin-Williams Comp User: Kristen Jasinski 12 - Job / Address / Class: 2225 23rd St SW 11 - Expense Category: Construction Materials ( Card: Physical I Budget: 10/2/2025 Sherwin Williams WKJ Holdings I Merchant Address: 800-4743794, OH 44115 334.07 DP WATER TREATMENT, 10/3/2025 LLC. DP WATER TREATME/SALE NAPLES FLORIDA VACATIO 407.58 10/3/2025 Hunter Pools HUNTER POOLS INC/SALE NAPLES FLORIDA VACATIO 927.72 The Sherwin-Williams Comp User: Kristen Jasinski 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Construction Materials 4 Notes: Paint I Card: Physical I Budget: WKJ Holdings I Merchant Address: 800- 10/812025 Sherwin Williams 4743794, OH 44115 431.84 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/9/2025 Home Depot 341090000 83.38 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job / Address J Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 101912025 Home Depot 341090000 18.00 10/9/2025 Gayo Jose Rodriguez ACH MKE Prefunding ACH Offset 251010 XXXXXX2879 3,000.00 eBay 0*14-13679-05101 User: Kristen Jasinski 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Construction Materials 4 10/10/2025 Ebay Notes: Hardware for laundry cabinets I Card: Ebay I Budget: WKJ Holdings 121.09 LOWES #02261User: Dumitru Ceban 12 - Job I Address I Class: Knickerbocker 2225 23rd Street SW 1 - Expense Category: Materials 13 - Bill to:: None I Card: Physical 10/10/2025 Lowe's Budget: WKJ Holdings I Merchant Address: NAPLES, FL 34113 19.69 THE HOME DEPOT #0280 User: Kristen Jasinski 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 1 - Expense Category: Construction Materials 4 10/10/2025 Home Depot Notes: Lights for well house exterior Card: Physical I Budget: WKJ Holdings 45.68 THE HOME DEPOT #6348 User: Dumitru Ceban 12 - Job I Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:. None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/11/2025 Home Depot 341120000 51.86 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job / Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/11/2025 Home Depot 341090000 18.00 10/141202.5 Dumitru Ceban ACH MKE Prefunding ACH Offset 251020 XXXXXX2879 1,817.69 10/1412025 Earthworks of Naples Check 25 850.00 1011412025 Stone Express ACH MKE Prefunding ACH Offset 251020 XXXXXX2879 1,375.00 SHERWIN-WILLIAMS702002 User: Dumitru Ceban 12 - Job / Address I Class: Knickerbocker 2225 23rd Street SW 1 1 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/15/2025 Sherwin Williams 34103 132.73 EXHIBIT - 106 - PAGE - 002 EXHIBIT - 063 - PAGE - 002 L. CIRCLE K # 23989 User: Dumitru Ceban 12 -Job/ Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Administrative expense 13 - Bill to:: None 10/15/2025 CIRCLE K I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 34119 75.79 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job I Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10116/2025 Home Depot 341090000 32.08 Francisco De Paz Hard 10/1712025 Concrete Service ACH MIKE Prefunding ACH Offset 251020 XXXXXX2879 3,500.00 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job / Address I Class: Knickerbocker 2225 23rd Street SW I 1 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/18/2025 Home Depot 341090000 25.33 THE HOME DEPOT #6348 User: Dumitru Ceban 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials 13 - Bill to:: None I Card: Physical I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 10/19/2025 Home Depot 341120000 41.38 10/21/2025 Stone Express ACH MIKE Prefunding ACH Offset 251022 XXXXXX2879 1,345.00 SUNSHINE ACE -GOLDEN GAT User: Dumitru Ceban 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Materials I Card: Physical Budget: WKJ Holdings I Merchant Address: NAPLES, FL 34116 1 Cleared Time in 10/22/2025 Sunshine Ace Hardware Statement (MT): 2025-10-22 02:34:39 52.54 DP WATER TREATMENT, 1012412025 LLC. DP WATER TREATME/SALE NAPLES FLORIDA VACATIO 971.42 10/24/2025 Christopher Hall ACH MIKE Prefunding ACH Offset 251028 XXXXXX2879 3,313.66 10/24/2025 Gayo Jose Rodriguez Payment to Gayo 2,800.00 THE HOME DEPOT #0280 User: Dumitru Ceban 12 - Job I Address / Class: Knickerbocker 2225 23rd Street SW I 1 - Expense Category: Materials I Card: Physical 10/26/2025 Home Depot I Budget: WKJ Holdings I Merchant Address: NAPLES, FL 341090000 53.99 10/29/2025 Stone Express ACH MIKE Prefunding ACH Offset 251104 XXXXXX2879 1,757.00 11/3/2025 Architechural Design LLC ACH MKE Prefunding ACH Offset 251107 XXXXXX2879 40.00 DP WATER TREATMENT, 11/412025 LLC. DP WATER TREATME/SALE NAPLES FLORIDA VACATIO 4,991.95 11/4/2025 Hunter Pools HUNTER POOLS INC/SALE NAPLES FLORIDA VACATIO 168.51 FERGUSON ENT #134 User: Kristen Jasinski 12 - Job I Address / Class: Knickerbocker 2225 23rd Street SW I 1 - Expense Category: Construction Materials 14 - Notes: Faucet for laundry room I Card: Physical I Budget: WKJ Holdings I Merchant 11/6/2025 Ferguson Plumbing Address: NAPLES, FL 341040000 395.53 11I7/2025 Earthworks of Naples EARTHWORKS OF NA/SALE NAPLES FLORIDA VACATIO 7,290.00 PAYMENTUS CORP User: Kristen Jasinski 12 - Job / Address / Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Permits 14 - Notes: Code enforcement 11 /712025 Collier County hearing fee main house I Card: Physical I Budget: WKJ Holdings 3.47 COLLIER COUNTY User: Kristen Jasinski 12 - Job I Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Permits 14 - Notes: Code enforcement 11/712025 Collier County hearing fee main house I Card: Physical I Budget: WKJ Holdings 111.90 PAYMENTUS CORP User: Kristen Jasinski 12 - Job / Address I Class: Knickerbocker 2225 23rd Street SW 11 - Expense Category: Telephone & Internet 14 - Notes: Code 11/712025 Collier County enforcement hearing fee well house I Card: Physical I Budget: WKJ Holdings 3.47 Francisco De Paz Hard ACH MIKE Prefunding ACH Offset 251110 XXXXXX2879 11 /10/2025 Concrete Service Trench for electrics & posts to mark corners 1,410.00 11/12/2025 Naples Lumber Naples Lumber &/Naples WKJH 233.03 11/13/2025 Stone Express ACH MIKE Prefunding ACH Offset 251113 XXXXXX2879 753.00 11/20/2025 Christopher Hall ACH MIKE Prefunding ACH Offset 251126 XXXXXX2879 320,57 THE HOME DEPOT #6348 User: Dumitru Ceban 2 - Job I Address / Class: Knickerbocker 11 - Expense Category: Materials 3 - Bill to:. None 14 - Notes: bill 11/20/2025 Home Depot business next door, for fixing ceiling tiles I Card: Physical I Budget: WKJ Holdings 28.38 12/1/2025 Earthworks of Naples EARTHWORKS OF NA/SALE NAPLES FLORIDA VACATIO 623.75 12/5/2025 Henry Johnson Law Attorney Fees 11,000.00 12/30/25 Henry Johnson Law Attorney Fees 9797.75 1/1/2026 Golden Gate Electric Remaining Costs to complete Service Upgrade 18000 251,864.90 EXHIBIT - 106 - PAGE - 003 EXHIBIT - 063 - PAGE - 003 Case Number: CELU20240001051 Date: March 25, 2024 Investigator: Charles Marinos Phone:2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Registered Agent: KIKU HOLDINGS, LLC 2805 HORSESHOE DR S STE 10 Naples, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00o19'10"W FOR 150.00 FT; N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: General Provisions. Land Use. Collier County Land Development Code 04-41 as amended, Section 1.04.01(A) A. The provisions of this LDC shall apply to all land, property and development in the total unincorporated area of Collier County except as expressly and specifically provided otherwise in this LDC. No development shall be undertaken without prior authorization pursuant to this LDC. Specifically, no building, structure, land or water shall hereafter be developed, or occupied, and no building, structure, or part thereof shall be erected, reconstructed, moved, located, or structurally altered except in conformity with the regulations set forth herein and for the zoning district in which it is located. The Collier County Land Development Code, 2004-41, As Amended, Section 2.02.03, Prohibited Uses. Any use or structure not specifically identified in a zoning district as a permitted use, conditional use, or accessory use shall be prohibited in such zoning district. Violation Status - Initial DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATION(S). Did Witness: An improved estates zoned property conducting event hosting activities which is not permissible on this site. ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Must comply with all land use standards of the Collier County Land Development Code 04-41, as amended 2. Cease the event hosting activity, which is not a permitted, accessory, or conditional use in this zoning district. ON OR BEFORE: 04/25/2024 EXHIBIT - 064 - PAGE - 001 Case Number: CELU20240001051 Date: March 25, 2024 Investigator: Charles Marinos Phone:2392806960 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $500 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. SERVED BY: elsud' 71(azurod Investigator Signature Charles Marinos Case Number: CELU20240001051 INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Phone: 239 252-2440 FAX: 239 252-2343 Signature and Title of Recipient Printed Name of Recipient Date *This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 064 - PAGE - 002 Case Number: CELU20240001051 Date: March 11, 2024 Investigator: Charles Marinos Phone: 2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00o19'10"W FOR 150.00 FT; N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: General Provisions. Land Use. Collier County Land Development Code 04-41 as amended, Section 1.04.01(A) A. The provisions of this LDC shall apply to all land, property and development in the total unincorporated area of Collier County except as expressly and specifically provided otherwise in this LDC. No development shall be undertaken without prior authorization pursuant to this LDC. Specifically, no building, structure, land or water shall hereafter be developed, or occupied, and no building, structure, or part thereof shall be erected, reconstructed, moved, located, or structurally altered except in conformity with the regulations set forth herein and for the zoning district in which it is located. The Collier County Land Development Code, 2004-41, As Amended, Section 2.02.03, Prohibited Uses. Any use or structure not specifically identified in a zoning district as a permitted use, conditional use, or accessory use shall be prohibited in such zoning district. Violation Status - Initial DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATION(S). Did Witness: An improved estates zoned property conducting event hosting activities which is not permissible on this site. ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Must comply with all land use standards of the Collier County Land Development Code 04-41, as amended 2. Cease the event hosting activity, which is not a permitted, accessory, or conditional use in this zoning district. ON OR BEFORE: 03/25/2024 EXHIBIT - 064 - PAGE - 003 Case Number: CELU20240001051 Date: March 11, 2024 Investigator: Charles Marinos Phone:2392806960 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $500 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. SERVED BY: (�luc� �%2azl�sac INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Investigator Signature Phone: 239 252-2440 FAX: 239 252-2343 Charles Marinos Case Number: CELU20240001051 Signature and Title of Recipient Printed Name of Recipient Date *This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 064 - PAGE - 004 CODE ENFORCEMENT- - SPECIAL MAGISTRATE COLLIER COUNTY. FLORIDA IMARD OF C'O(:NTN' CON911tSSIONFRS COLLIFA COUNTY, FLORIDA, Petilioner. I ON ANCY LLC Respondent. Case No. CESD20240001058 CESD20240001061 CELU20240001051 C E PM20240001063 C ESTV R20240000530 ORDER OF THE SPECIAL_ MAGISTRATE 1111S CM'SE carve betbre the Slxcial Magistrate tOr public hearing on .tune 7. 2024, and the 'vecial Magistrate. haying received e\ idence and heard argument respective to all appropriate matter,,, hereupon issue; his findings of Fact. Conclusions of km and Order of the Special Magistrate. a: l011mcs: FINDINGS OF FACT and CONCLUSIONS OF LAW 1. Respondent. BUOYANCY I.I.0 is the owner of the propertt located at 2225 23rd St Sw'. Naples. Fl. 34117. Folio 459602.10004 (Subject Propertv). 2. Respondent. Kristen Jasinski. the authorized rcpresentati\e of the Respondent. \\as dulh notified ofthe date of hearing b} certilicd mail and posting and \gas present at the he rintt \N ith attorney Joseph Gugino, E.N identian- batters 3. i he Respondent objected to the e\ idence to he presented in the cases base(] upon the accca.S granted to the SubJect Properh b� an occupant of the Subject Propem . t. An eztenske hearing k�as held N\ith teslimom• b\ Ms. Kristen Jasinski, the authorized representative ofthe Respondent. rode Ftil'orcement personnel. documentar\ and pictorial e\ idence by both parties. and argument and authorities presented by counsel liar the Petitioner and the Respondent. :. I he e\ idenec and testimom supported the conclusion that Ms. Lauren IJames. the complainant in these cases. �\as a legal occupant of the Subject PropertN on Janmrr� 26. 202 1, hen the inspection occurred. 6. Op. Att'� Gen. Fla. 2002-27 cited bN the Respondent pro\ ides in rele\ ant part that '... municipal code inspector k \� ithout aut)u0rit\ to enter onto an\ prig ate, commercial. or EXHIBIT - 064 - PAGE - 005 v residential property to assure compliance %%ith or to enforce the \ arious technical codes of tits county or to conduct any administrati\e inspections or searches without the consent ofthe owner or the operator or occupant of sttch premises....- (I.mphasis added hs Special Magistrate). 7. 1s it xsas determined that M.". Ilames X�as a legal "occupant' of the Stthject Propcli\. the :attorney General Opinion and other auIhontius cited support the cone lusioil that evidence obtained from the inspection conducted h\ the Collier County Code Fni6rcemcnt Off ices Charles Marinos seas leoalh obtained and ntay. subject to other objections or exclusions raised by either part\ and sustained h\ the Special Magistrate. he admitted as evidence in these cases. Case No. CESD20240001058 The Petitioner presented substantial competent e� idence in the form of testimony and pictorial evidence that prmcd b% a preponderance of the cvidence that the real property ofthe Respondent is in � iolation ofthe Collier Count\ land Development Code 04.41. as amended. Suctions 10.010603)( 1)(a), 10.02.06(11)( 1 )(c) and 10.02.06(B)( I )(e)(i) to wit an improved estates zoned propert\ \\ith extensive changes to the primary structure inCluding but not limited to the lollowinv.: interior renovations, deletion of \galls, addition of \Ills, electrical modifications, plumbing modifications, addition of multiple HVAC units. deletion of wet harrkitchen and ,team rooms. \\ ithout proper permits. 9. The violation had not been abated as ofthe date of the public hearing. Respondent presented testinton} that no one is currently occupying the premises. Case No. CESD20240001061 10, The Petitioner presented substantial competent e\ idence in the brit of testimony and pictorial evidence that proved by a preponderance of the evidence that the real propero. ofthe Respondent is in violation of the Collier County Land De\ elopment Code 04-41. as amended. Sections I0.02.06(B)( I )(a). 10.02.06(B)( I )(c) and 10.02.06(B)( i )(e)(i) to ,Nit an improved hstates zoned property with a pump house in the rear erected without permits and including, electrical and plumbing modifications, 11. The violation had not been abated as ofthe date of the public hearing. Case No. CELU202400010 I 12. 'file Petitioner presented substantial competent evidence in the form oftestiniony and pictorial evidence that proved bM a preponderance of the evidence that the real propert\ of the Respondent is in � iolation of the Collier County Land Des elopment Code 04-41. as amended. Sections 1.04.0lW and 2.02.0 to wit an improved Estates zoned propem conducting ekent hosting activities which is not permissible on this site. Respondent presented testimony that Lill perm ittcd cents are not taking place. Case No. CE:P1120240001063 13. The Petitioner presented substantial competent evidence in the iorttt of testimony and pictorial evidence that proved b} a preponderance ofthe evidence that the real propert\ of the Respondent is in v iolation of the Collier Count\ I .and Dcrelopment Code 04-41. as amended. EXHIBIT - 064 - PAGE - 006 Sections 10.02.06(13)( 1 )(a) and 10.02.06(13)( 1)(c)(i) and Florida Building Code. 8th l:.dition (2023) Chapter 4. Section 454.2.17.1 through 4-i4?_ i 7.3 to %%it an improved Instates zoned propert% % ith a pool cage not meeting Florida Building Code standards on site. Case No. CESTV1220240000530 14. fhe Petitioner presented substantial competent evidence in the form ofte,timonN and pictorial evidence that pro%ed bN a preponderance of the evidence that the real propert} of the Respondent is in violation of the Collier Countx Land Development Code 04-41, as amended. Sections 2.02.03 and 5.02.03(J). and Collier County Code of I.aws and Ordinances. Article X. Sections 26-38.4( 1 ). 26-384(2) and'_6-384(4) to %\ it an improved Estates zoned propert} being utilized for short term vacation rentals \Kith multiple rooms being rented to multiple. unrelated parties at the same time in a manner similar to a hotel \\ hich is not an allot able usage on site. Additionall%. the short-term rental(s) are being done without the required Collier CountN Registration Approval. tt hich includes. but is not limited to: Valid Florida D.13T.R. Licensure. a Collier CountN Business Tax Receipt, and an approved Short Ternt Rental Registration Form. U111)E11 Based upon the Foregoing Findings of Fact and Conclusions of Latt, and pursuant to the autltor16 Granted in Chapter 162, Florida Statutes, and Collier C'ountN Ordinance No, 07-44. as amended. IT' IS HEREBY ORDERED: Case No. CESD20240001058 A. Respondent is found guilty of t iolation of Collier Count\ Land Development (.'ode 04-41. as amended. Sections 10.02.06(B)( I )(a), 10.02.06(B)(1)(e) and 10.02.06(B)(1)(e)(i) to wit an improved estates zoned propert} ttith extensive changes to the primary structure including but not limited to the lollotving: interior renovations, deletion ofwalls. addition of walls, electrical ntoditications. plumbing modifications. addition of multiple FIVAC units, deletion of ttet har"kitchen and steam rooms tt ithout proper permitting. 13. Respondent is ordered to pa-, operational costs in the amount of Sl 11.70 incurred in the prosecution of this case % ithin thirty (30) calendar days from the date of this hearing (.luh ". 2024). C. Respondent must abate the t iolation by Obtaining all required Collier County Building Permit(s) or Demolition Permit, inspections, and Certificate of Completion/Occupancy for the unpermitled renovations of the prirnan. structure including, but not limited to: deletion of stalls, addition of walls, plumbing modifications, electrical modifications, and addition of multiple air conditioning units within 120 calendar days of the date of this hcarint4 (October 5, 2024) or a fine of S250.00 per dad will be imposed until the violation is abated. EXHIBIT - 064 - PAGE - 007 Case No). CESD20240001061 A. Respondent is found guilt, of � iolation of Collier County Land Dc\ clopmcnt Code 04-4 1. as amended. Sections 10.02.06([3)(1 )(a). I0.02.06(B)(1)(e) and 10.02.06(11)( I)(c)(i) to wit an improved Estates zoned propertv \� ith a pump house in the rear erected without permits and including electrical and plumbing modifications. 13. Respondent is ordered to pay operational costs in the amount of $1 1 1.70 incurred in the prosecution of this case within thirt} (30) calendar dais from the date of this hearing (July 7, 2024). C. Respondent must abate the � iolation b\ obtaining all required Collier Count} Building Permit(,) or Demolition Permit. inspections. and Certificate of Completion'Occtthancy for the unpermitted pump house and the unpermitted modification to the related plumbing within 120 da\s of this hearing (October ;. 2024) or a fine of $200 per day will he imposed until the violation is abated. Case No. CELU20240001051 A. I his matter is Dismissed. Case No. CEPM20240001063 A. ']'his matter is Continued for 56 da\s to the August 2. 2024. Special Magistrate hearing at \%hich time Respondent will present a report confirming that no health and salct) violations are present. Case No. CESTVR20240000530 A. 7-his matter is Continued to the Juh 12. 2024. Special Magistrate hearing prior to \%hick time Respondent and Petitioner is ill each present a legal memo regarding, the legality and regulation 01' short-term rentals in Estates zoned properties. All Cases A. Respondent shall notify the Code Fiflorcement Investigator %N ithin 24 hours of abatement or compliance in order for the County to conduct a final inspection to confirm abatement. 11. I f Respondent fails to abate the \ lolation and comply w ith this Order, the Collier Count} Codc Filforcernent Department ma\ abate the violation using any appropriate method to bring the iolation into compliance. If necessary, the Count\ may request the services of the Collier Count\ 'sheriff's Office in order to access the property for abatement and enforce the provisions oftltis Order. All costs of abatement shall he assessed against the property o\tiner and may become a lien on the property. EXHIBIT - 064 - PAGE - 008 OR DONE: AND ORDERED this 7th day of,lone. 2024, at Naples, Collier Count', Ftoridst. I wcuted b COLLIER COUNTY CODE. ENFORCEMENT SPECIAL NIA(A SYt2.-kTE fC Mtrick Ti. Neale, Esq. Special (Magistrate Patrick 11. Neale on � _ �,�' -024. —f - 1 iled \� ith the Seaetary to the Special Magistrate on ��� 2024 bN PAYMENT OF FINES: Any tines ordered to be paid pursuant to this order may be paid at the Collier County Cade Lill'Orcement Division, 2800 North Horseshoe Drive, Naples. FL 3.110.1. phone r,' (239) 252- 2.440 or „w,, Il��r :. unto IL�n� . Any release of lien or confirtnatiort of e()rnpliance or contirntzttion of the satisfaction of the obligations of this order may also be obtained at this location. APPEAL: An\ aggrieved part} may appeal a final order of the Special Magistrate to the Circuit Court ithin thirh (0) days of the execution of the Order appealed. An appeal shall not be a hearing de nog o but shall he limited to appellate rep ie\\ of the record created \� ithin the original hearing. It is the responsibilit} of the appealing party to obtain a transcribed record of the hearing li•om the C'Icrl. ,�f Courts. Filing a Notice of Appeal \sill not automatically stay the Special Magistrate's Order, CERTIFICATE OF SERVICE I IiE:RF.BY CERTIFY that a true and correct copy of this 1ORDER OF TIIF' SPECIAL iMAGISTRAT F. has been sent b\ 1'.S. Mail or this day otJC, � ^_ 2024 to Respondent. BWYANCY 1.1 C. 2805 I IORSE:S110Y, DK S. LIT 10. NAPL S. FL 3 11041. Code 1.nt c11101 Official EXHIBIT - 064 - PAGE - 009 Case Number: CEPM20240001063 Date: February 26, 2024 Investigator: Charles Marinos Phone:2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Registered Agent: KIKU HOLDINGS, LLC 2805 HORSESHOE DR S STE 10 Naples, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00o19'10"W FOR 150.00 FT: N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: Florida Building Code 8th Edition (2023) Building. Chapter 4 Special detailed requirements based on use and occupancy, Section 454 Swimming pools and bathing places, 454.2.20 Residential swimming barrier requirement. Residential swimming pools shall comply with Sections 454.2.17.1 through 454.2.17.3 Building and Land Alteration Permits. (Permits, Inspections, Certificate of Occupancy Required) Collier County Land Development Code 04-41, as amended, Section 10.02.06(B)(1)(a) The County Manager or his designee shall be responsible for determining whether applications for building or land alteration permits, as required by the Collier County Building code or this Code are in accord with the requirements of this Code, and no building or land alteration permit shall be issued without written approval that plans submitted conform to applicable zoning regulations, and other land development regulations. For purposes of this section a land alteration permit shall mean any written authorization to alter land and for which a building permit may not be required. Examples include but are not limited to clearing and excavation permits, site development plan approvals, agricultural clearing permits, and blasting permits. No building or structure shall be erected, moved, added to, altered, utilized or allowed to exist and/or no land alteration shall be permitted without first obtaining the authorization of the required permit(s), inspections and certificate(s) of occupancy as required by the Collier County Building Code or this Code : Submittal Requirements for Permits. Building or Land Alteration Permits. Improvement of property prohibited prior to issuance of building permit. Collier County Land Development Code 04-41 as amended, Section 10.02.06(B)(1)(e)(i) Must obtain all required inspections and certificate of occupancy/completion within 60 days of permit issuance. Violation Status - Initial DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATION(S). Did Witness: An improved estates zoned property with a pool cage not meeting FBC standards on site. EXHIBIT - 065 - PAGE - 001 Case Number: CEPM20240001063 Date: February 26, 2024 Investigator: Charles Marinos Phone:2392806960 ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Must erect, fix, or repair an approved pool barrier to avoid safety concerns AND / OR Must apply for and obtain applicable permits for a permanent pool enclosure and/or protective barrier and follow through to certificate of completion. 2. Must obtain all required Collier County Building Permit(s) or Demolition permit(s) and request all inspections through Certificate of Completion/Occupancy for described structure/ alteration. ON OR BEFORE: 03/27/2024 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $500 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. SERVED BY: 61fad,• Va.zovmd Investigator Signature Charles Marinos Case Number: CEPM20240001063 INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Phone: 239 252-2440 FAX: 239 252-2343 Signature and Title of Recipient Printed Name of Recipient Date *This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 065 - PAGE - 002 Code Case Details Execution Date 12/8/2025 4:21:23 PM Desc Assigned Required Completed Outcome Comments CE Staff Review Charles.Marin 6/20/2024 6/20/2024 Complete Duplicate entry. CM88 os Post Hearing Re -Inspection Charles.Marin 6/20/2024 6/20/2024 Non- Ron Tomasco and Derrick Perry currently are os Compliant preparing legal opinion requested by the special magistrate. CM88 Update Picture(s) Charles.Marin 6/20/2024 6/20/2024 Complete os CE Staff Review Charles.Marin 6/20/2024 6/20/2024 Complete Duplicate entry. CM88 os CE Mailing Miriam.Lorenz 7/3/2024 7/3/2024 Complete Mailed copy of Continued Order ( not o recorded) to respondent from the June 7, 2024 OSM Hearing./ML Re -Inspection Charles.Marin 7/5/2024 7/5/2024 Compliant Permit PREL20240311475 for the installation os of required safety devices for pool is in "Finaled" status. Recommending case closure at this time. Responded to email from property manager Kristen Jasinski informing thanking her for her compliance efforts and case recommendation. MarinosCharles 07/05/2024 9:42 AM Enter Case Disposition Charles.Marin 7/5/2024 7/5/2024 Complete os CE Staff Review Miriam.Lorenz 7/5/2024 7/10/2024 Complete AOC attached./ML o Please scan and notorize signed AoC. CM88 Generate Hearing Results Notice Miriam.Lorenz 7/5/2024 7/3/2024 Complete 7/3124 Scanned & attached Continued Order (CE) o (not recorded) from the June 7, 2024, OSM Hearing./ML CE Legal Review Miriam.Lorenz 7/10/2024 7/10/2024 Not Compliant on July 4, 2024./ML o Required Case was continued to August 2, 2024, OSM Hearing./ML Verify Conditions & Close Case BradleyHolme 7/11/2024 7/12/2024 Complete s Violation Description Status Entered Corrected Amount Comments Swimming Pool Barrier - Residential FBC 2020 Corrected 2/23/2024 7/4/2024 $0 Building Permit LDC Corrected 2/23/2024 7/4/2024 $0 CO Required ATF Permits Corrected 2/23/2024 7/4/2024 $0 Title Reason Result Compliance Fine/Day Condition Special Magistrate Hearing on Code Review Continued $0 OSM Ops costs .AE 6/7/2024 by Petitioner Business Management &Budget Office 4 EXHIBIT - 065 - PAGE - 003 Case Number: CESTVR20240000530 Date: March 25, 2024 Investigator: Charles Marinos Phone:2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Registered Agent: KIKU HOLDINGS, LLC 2805 HORSESHOE DR S STE 10 Naples, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00o19'10"W FOR 150.00 FT; N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: The Collier County Land Development Code, 2004-41, As Amended, Section 2.02.03, Prohibited Uses. Any use or structure not specifically identified in a zoning district as a permitted use, conditional use, or accessory use shall be prohibited in such zoning district. The Collier County Code of Laws & Ordinances, Article XX, Section 26-384(1) Register with the Florida Department of Business and Professional Regulation and the Collier County Tax Collector. Failure to obtain the required Florida Department of Business and Professional Regulation Vacation Rental License, The Collier County Code of Laws & Ordinances, Article XX, Section 26-384(2) Register with the Florida Department of Business and Professional Regulation and the Collier County Tax Collector. Obtain a Collier County Registration Certificate for each short-term vacation rental unit owned. The Collier County Code of Laws & Ordinances, Article XX, Section 26-384(4) Register with the Florida Department of Business and Professional Regulation and the Collier County Tax Collector. Maintain all short-term vacation rental units in compliance with the occupancy limits, as specified in the Collier County Code of Ordinances, Collier County Land Development Code, Florida Building Code, and Florida Fire Prevention Code. Home Occupations. Standards. Collier County Land Development Code 04-41 as amended, Section 5.02.03(J) J. A home occupation shall be subject to all applicable County occupational licenses and other business taxes. Violation Status - Initial EXHIBIT - 066 - PAGE - 001 Case Number: CESTVR20240000530 Date: March 25, 2024 Investigator: Charles Marinos Phone:2392806960 DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATION(S). Did Witness: An improved estates zoned property being utilized for short term vacation rentals with multiple rooms being rented to multiple, unrelated parties at the same time in a manner similar to a hotel which is not an allowable usage on site. Additionally, the short term rental(s) are being done without the required Collier County Registration/Approval, which includes, but is not limited to: Valid Florida D.B.P.R. Licensure, a Collier Count Business Tax Receipt, and an approved Short Term Rental Registration Form. ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Cease the subdivision and individual room rental activity, which is not a permitted, accessory, or conditional use in this zoning district. 2. Must obtain the required Florida DBPR Vacation Rental License AND/OR renew previously obtained Florida DBPR Vacation Rental License. 3. Must comply with all other license requirements of Collier County to include the County Occupational license(s) and any other business taxes. ON OR BEFORE: 04/25/2024 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $500 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. SERVED BY: &lfucl 7&4'r4srot Investigator Signature Charles Marinos Case Number: CESTVR20240000530 INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Phone: 239 252-2440 FAX: 239 252-2343 Signature and Title of Recipient Printed Name of Recipient Date "This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 066 - PAGE - 002 Code Case Details Execution Date 12/8/2025 2:35:56 PM Desc Assigned Required Completed Outcome Comments Hearing Notice Service/Posting Charles.Marin 6/19/2024 6/20/2024 Complete Last day to post June 21, 2024./ML os Property posted on 19Jun2024 at 1453. CM88 CE Staff Review Charles.Marin 6/20/2024 6/21/2024 Complete Duplicate entry. CM88 os Affidavit of Service/Posting Charles.Marin 6/20/2024 6/20/2024 Complete os CE Staff Review Miriam.Lorenz 6/20/2024 6/21/2024 Complete AOM_AOP_NOH attached./ML Please scan and notorize signed AOP. CM88 CE Mailing Miriam.Lorenz 7/3/2024 7/3/2024 Complete Mailed copy of Continued Order ( not recorded) to respondent from the June 7, 2024 OSM Hearing./ML Generate Hearing Results Notice Miriam.Lorenz 7/5/2024 7/3/2024 Complete 7/3124 Scanned & attached Continued Order (CE) o (not recorded) from the June 7, 2024, OSM Hearing./ML Pre Hearing Inspection Charles.Marin 7/11/2024 7/11/2024 Complete DBPR, Vacation rental agreedment, and BTR os are up to date and issued. CM88 Record Hearing Results Miriam.Lorenz 7/15/2024 7/15/2024 Complete 7/12/24 Respondent was present Kristen o Jasinski along with Attorney Morgan Hila Esq. Stipulation Agreement. Respondent must abate all violations by, Cease the individual room rental activity and renting to more than four(4) unrelated individuals within 30 days (August 11, 2024) of this hearing, or a fine of $200.00 a day will be imposed until all the violations are abated and pay operational costs for the prosecution of this case in the amount of $111.75 on or before August 11, 2024 (30 days)./ML Post Hearing Re -Inspection Charles.Marin 7/25/2024 7/30/2024 Compliant Received email from property manager os stating that a good faith effort had been made to remove all listings from problem websites showing the knickerbocker having individual rooms for rent, see email and attachment, research shows that some of these sites have the listings removed and some don't but it appears that the efforts we requested have been made. Email from management staff indicates that VRBO is listed via software in common use by rental companies, VRBO listing is now showing as unavailable. Sent an email to knickerbocker as well as legal counsel thanking them for their compliance efforts and informing them of recommendation for case closure. MarinosCharles 07/30/2024 1:52 PM Generate Hearing Results Notice Miriam.Lorenz 7/25/2024 8/9/2024 Complete Scanned & attached FF & Stipulation Order (CE) o (not recorded) from the July 12, 2024, OSM Hearing./ML CE Supervisor Review (CE) BradleyHolme 7/30/2024 7/30/2024 Complete Please see attached email and attachements s and advise if I should enter a compliant order. CM88 Reviewed case with investigator. BH91 Not Applicable Miriam.Lorenz 7/30/2024 8/7/2024 Not o Required business Management & Budget Office EXHIBIT - 066 - PAGE - 003 Case Number: CEVR20240001060 Date: March 05, 2024 Investigator: Charles Marinos Phone: 2392806960 COLLIER COUNTY CODE ENFORCEMENT NOTICE OF VIOLATION Owner: BUOYANCY LLC 2805 HORSESHOE DR S UNIT 10 NAPLES, FL 34104 Registered Agent: KIKU HOLDINGS, LLC 2805 HORSESHOE DR S STE 10 Naples, FL 34104 Location: 2225 23rd ST SW, Naples Unincorporated Collier County Zoning Dist: E Property Legal Description: GOLDEN GATE EST UNIT 195 TR 5 LESS THE FOLLOWING: BEG AT NE CNR OF TR5, RUN S00019'10"W FOR 150.00 FT; N89o40'50"W FOR Folio: 45960240004 NOTICE Pursuant to Collier County Consolidated Code Enforcement Regulations, Collier County Code of Laws and Ordinances, Chapter 2, Article IX, you are notified that a violation(s) of the following Collier County Ordinance(s) and or PUD Regulation(s) exists at the above -described location. Ordinance/Code: Vegetation Removal, Protection & Preservation. Vegetation Removal I Landfill Required. Collier County Land Development Code 04-41, as amended, Section 3.05.01(B) It shall be unlawful for any individual, firm, association, joint venture, partnership, estate, trust, syndicate, fiduciary, corporation, group, or unit of federal, state, County, or municipal government to remove, or otherwise destroy, vegetation, which includes placing of additional fill, without first obtaining a vegetation removal or vegetation removal and fill permit from the County Manager or designee, except as hereinafter exempted. Violation Status - Initial DESCRIPTION OF CONDITIONS CONSTITUTING THE VIOLATIONS). Did Witness: An improved estates zoned property with overclearing on site requiring an after the fact vegetation removal permit AND/OR restoration plan. ORDER TO CORRECT VIOLATION(S): You are directed by this Notice to take the following corrective action(s): 1. Must cease all land clearing, excavation, and/or land fill operations AND/OR Must obtain any and all applicable permits to include Vegetation Removal or Vegetation Removal and Land Fill permits pursuant to 04-41, as amended, Section 10.02.06(B)(1)(a) AND/OR Must obtain any and all applicable permits to include Vegetation Removal or Vegetation Removal and Land Fill permits pursuant to 04-41, as amended, Section 10.02.06(B)(1)(a) ON OR BEFORE: 04/04/2024 Failure to correct violations may result in: 1) Mandatory notice to appear or issuance of a citation that may result in fines up to $600 and costs of prosecution. OR 2) Code Enforcement Board review that may result in fines up to $1000 per day per violation, as long as the violation remains, and costs of prosecution. EXHIBIT - 067 - PAGE - 001 SERVED BY: Investigator Signature Charles Marinos Case Number: CEVR20240001060 Case Number: CEVR20240001060 Date: March 05, 2024 Investigator: Charles Marinos Phone:2392806960 INQUIRIES AND COMMENTS SHOULD BE DIRECTED TO CODE ENFORCEMENT 2800 North Horseshoe Dr, Naples, FL 34104 Phone: 239 252-2440 FAX: 239 252-2343 Signature and Title of Recipient Printed Name of Recipient Date *This violation may require additional compliance and approval from other departments which may be required under local, state and federal regulations, including, but not limited to: right-of-way permit, building permit, demolition of structure, Site Development Plan, Insubstantial Change to Site Development Plan, and Variances along with, payment of impact fees, and any new or outstanding fees required for approval. EXHIBIT - 067 - PAGE - 002 Code Case Details Execution Date 12/8/2025 3:59:35 PM Desc Assigned Required Completed Outcome Comments CE Staff Review Donna.Gentsc 3/14/2024 3/14/2024 Complete Green card NOV to Agent received 3/14/24 h 7022 3330 0000 8410 7961 CE Staff Review Donna.Gentsc 3/14/2024 3/14/2024 Complete Green card NOV to Owner received 3/14/24 h 7022 3330 0000 8410 7954 Re -Inspection Charles.Marin 3/22/2024 3/22/2024 Compliant Discovered Code Case #2000080424 os addressed the land clearing on site. Due to no changes in the condition of the property since that time, as evidenced by GIs aerials dating back to 2000, recommending case closure at this time as no violation found. Attempted to contact Attorney Mr Joseph Gugino (239.405.8033), no answer. Left a message requesting a return phone call. Composing email to advise of case outcome. MarinosCharles 03/22/2024 2:47 PM Enter Case Disposition Charles.Marin 3/22/2024 3/22/ 0024 Complete os Verify Conditions & Close Case BradleyHolme 3/22/2024 4/9/2024 Complete s Violation Description Status Entered Corrected Amount Comments /egetation Removal (Landfill Permit) NOV Issued 3/5/2024 $0 Title Reason Result Compliance Fine/Day Condition Business Management & Budget Office EXHIBIT - 067 - PAGE - 003