Loading...
Agenda 10/14/2025 Item #16K 7 (County Attorney to file a lawsuit on behalf of Collier County Board of County Commissioners against RTS of Broward Corp., dba RTS Underground)10/14/2025 Item # 16.K.7 ID# 2025-3639 Executive Summary Recommendation to authorize the County Attorney to file a lawsuit on behalf of Collier County Board of County Commissioners against RTS of Broward Corp., d/b/a RTS Underground, and any other responsible parties for $40,829.29 in damages caused to a 6’ wastewater force main in front of 3313 Europa Drive, Naples, Florida and to sewer laterals located at 109, 124, and 215 Willowick Drive, Naples, Florida. OBJECTIVE: To recover the money spent by Collier County to repair County owned, operated, and maintained assets from the responsible negligent contractor. CONSIDERATIONS: On or about October 26, 2021, workers for RTS of Broward Corp., d/b/a RTS Underground (“RTS Underground”) damaged a 6-inch County wastewater force main while performing a directional bore involving cable work. The County was required to engage an emergency contractor and utilize staff resources to restore the County’s 6-inch wastewater force main, and the County incurred $6,217.41 in damages. RTS Underground has been contacted by the County’s third-party adjuster Johns Eastern Company, as well as by the County Attorney’s Office, several times with no responses received. On or about August 19, 2022, workers for RTS Underground damaged the County’s sewer laterals while performing directional boring activities. The County was required to engage an emergency contractor and utilize staff resources to restore the County’s sewer laterals, and the County incurred $34,611.88 in damages. RTS Underground has been contacted by the County’s third-party adjuster Johns Eastern Company several times with no responses received. The sum of the damages caused by RTS Underground to County assets is $40,829.29, not including other direct and consequential damages that may be recoverable. The County recommends Board of County Commissioner (“Board”) approval to file a lawsuit in county court to recover the damages. Attached is a draft copy of the complaint, along with corresponding backup materials documenting the damage and amounts thereof. By filing this lawsuit to recover damages, the County puts contractors on notice that they will be held responsible for their negligent actions. FISCAL IMPACT: The cost to file and serve a Complaint is approximately $410.00 and funds are budgeted and available in the Risk Management Property & Casualty Fund. GROWTH MANAGEMENT IMPACT: There is no growth management impact associated with this item. LEGAL CONSIDERATIONS: This item has been approved as to form and legality and requires a majority vote for Board approval. – CLD RECOMMENDATIONS: Recommendation to authorize the County Attorney to file a lawsuit on behalf of Collier County Board of County Commissioners against RTS of Broward Corp., d/b/a RTS Underground, and any other responsible parties for $40,829.29 in damages caused to a 6’ wastewater force main in front of 3313 Europa Drive, Naples, Florida and to sewer laterals located at 109, 124, and 215 Willowick Drive, Naples, Florida. PREPARED BY: Courtney L. DaSilva, Assistant County Attorney ATTACHMENTS: 1. RTS Complaint v.2(1)(3) 2. RTS Back Up Documents Page 5497 of 6526 IN THE COUNTY COURT OF THE TWENTIETH JUDICIAL CIRCUIT IN AND FOR COLLIER COUNTY, FLORIDA CIVIL ACTION BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, Plaintiff, vs. Case No.: _____________________ RTS OF BROWARD CORP., d/b/a RTS UNDERGROUND, a Florida Profit Corporation, Defendant. _____________________________________/ COMPLAINT Plaintiff, BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, (the “County”), by and through its undersigned counsel, sues Defendant, RTS OF BROWARD CORP., d/b/a RTS UNDERGROUND (“RTS UNDERGROUND”), a Florida Profit Corporation, and states as follows: NATURE OF CLAIMS, THE PARTIES, JURISDICTION, AND VENUE 1. The County’s claims stem from damage to the County’s personal property, specifically an underground 6-inch wastewater force main and sewer laterals, owned, operated, and maintained by the County, and the resulting cost of repair and mitigation incurred by the County. 2. This Court has jurisdiction over this matter, as it is an action to recover damages more than $8,000.00 and less than $50,000.00. 3. In personam jurisdiction is properly exercised over RTS UNDERGROUND because RTS UNDERGROUND is a Florida corporation and Florida courts have personal Page 5498 of 6526 jurisdiction over all Florida residents. See, e.g., Subic Bay Marine Exploratorium, Inc. v. JV China, Inc., 257 So. 3d 1139, 1141 (Fla. 5th DCA 2018). 4. The County, as the governing body for Collier County, Florida, a political subdivision of the State of Florida, and as the ex-officio governing board of the Collier County Water-Sewer District, an independent special district created by the Florida Legislature, is the owner of the personal property that is the subject of this litigation and is thus authorized to bring this action. 5. RTS UNDERGROUND is a profit corporation organized under the laws of Florida, with its principal place of business at 14810 Queen Ave, Clewiston, Florida 33440, in Hendry County, Florida, and is authorized to and does conduct business throughout the State of Florida, including in Collier County. 6. Venue is proper in Collier County, Florida, pursuant to Sections 47.011 and 47.051, Florida Statutes, because (i) this is an action against a domestic corporation, (ii) Collier County is where the instant cause of action accrued, (iii) Collier County is where the property in litigation is located, (iv) the property damage occurred in Collier County, and (v) the amounts due to the COUNTY are due in Collier County. FACTUAL ALLEGATIONS 7. In 1993, the Florida Legislature enacted the “Underground Facility Damage Prevention and Safety Act,” Chapter 556, Florida Statutes (“the Act”), to prevent injury to persons or property and the interruption of services resulting from damage to an underground facility caused by excavation or demolition operations. Fla. Stat. § 556.101(3)(a). 8. The Act created a not-for-profit corporation called Sunshine State One-Call of Florida, Inc. (the “Corporation”), and requires the Corporation to maintain a free-access Page 5499 of 6526 notification system (the “One-Call System” or “System”) which excavators can use to notify owners of underground facilities of planned excavation or demolition activities. See Fla. Stat. §§ 556.103, 556.104. 9. The Corporation is comprised of the owners of underground facilities in the State of Florida, which are called “member operators” by the Act. Fla. Stat. § 556.104. 10. The County is a “member operator” under the Act. 11. Under the Act, “excavators” and “excavating contractors” are required to notify the System and provide information about a planned excavation at least two full business days before beginning any excavation. Fla. Stat. § 556.105(1). The System then notifies member operators with underground facilities near the planned excavation, who are required to “identify the horizontal route by marking to within 24 inches born the outer edge of either side of the underground facility by the use of stakes, paint, flags, or other suitable means within two full business days after the time the notification is received” from the System. Fla. Stat. § 556.105(5) (emphasis added). 12. RTS UNDERGROUND is an “excavator” and/or “excavating contractor” under the Act because they performed the excavation work at issue. 13. RTS UNDERGROUND is a licensed Certified General Contractor in Florida with a license number CGC1527621. 14. Florida Power & Light Company hired RTS UNDERGROUND to perform excavation work at 3313 Europa Drive, 109 Willowick Drive, 124 Willowick Drive, and 215 Willowick Drive, Naples, Collier County, Florida. 15. Under the Act, “[w]hen an excavation site cannot be described in information provided under s. 556.105(1)(a) with sufficient particularity to enable the member operator to Page 5500 of 6526 ascertain the excavation site, and if the excavator and member operator have not mutually agreed otherwise, the excavator shall premark the proposed area of the excavation before a member operator is required to identify the horizontal route of its underground facilities in the proximity of any excavation. However, premarking is not required when the premarking could reasonably interfere with traffic or pedestrian control.” Fla. Stat. § 556.114(3). 16. RTS UNDERGROUND failed to notify the System of planned excavation work at 3313 Europa Drive. 17. On or around October 2021, RTS UNDERGROUND engaged in directional drilling activities at 3313 Europa Drive and hit and damaged the County’s owned, operated, and maintained wastewater force main. The County discovered damage to its wastewater force main on October 26, 2021. 18. Prior to performing the excavation work at 3313 Europa Drive, the County provided a positive response code “3N” and requested that RTS UNDERGROUND “white line” the proposed excavation. 19. The System provides response codes on its website https://sunshine811.com/response-codes, stating “[n]ext to getting your locate ticket, confirming and verifying member positive responses is essential to preventing damage to underground facilities. By comparing what you see at your excavation/dig site to the positive response codes for your locate ticket, you can determine whether it's safe to begin digging or do some follow up with the member operator.” 20. The System’s definition of the 3N positive response code on its website https://sunshine811.com/response-codes is as follows: 3N Unmarked: Locate description is insufficient - white lining is required per s. 556.114(3), F.S. Please contact the utility when white lining is completed. Page 5501 of 6526 Excavation site is unmarked. Based on the written description on the ticket, the locate technician could not determine the exact area that needed locating. White lining is required per s. 556.114(3), F.S., when the written description of the area to be located is not understandable and when the marks don't interfere with traffic or pedestrian control (i.e. placing white marks on the ground could be confused with the lines already on pavement directing pedestrian and car traffic). 21. RTS UNDERGROUND failed to respond to the County’s 3N positive response code and failed to white line the projected boring path resulting in damage to the County’s wastewater force main. 22. On August 14, 2022, RTS UNDERGROUND’s representative, Anabel Alomar, notified the System of a planned excavation at the North and South side of Willowick Drive between Turnbury Way and Lakeland Avenue. 23. On August 17, 2022, RTS UNDERGROUND’s representative, Antonio Leon, notified the System of a planned excavation at the entire property located at 103, 109, 119, 123, 127, 215, 223, 229, 235, and 239 Willowick Drive. 24. On August 23, 2022, the County marked the underground utilities at the locations described in paragraphs 22 and 23 of the Complaint. 25. On or around August 19, 2022, RTS UNDERGROUND engaged in underground boring activities at 109, 124, and 215 Willowick Drive and hit and damaged the County’s owned, operated, and maintained sewer laterals. 26. “If any excavator fails to discharge a duty imposed by [the Act], the excavator, if found liable, is liable for the total sum of the losses to all parties involved as those costs are normally computed.” Fla. Stat. § 556.106(2)(b). 27. As a result of RTS UNDERGROUND’s negligence, the County incurred monetary damages, including but not limited to the cost to repair the County’s wastewater force main and sewer laterals in the total amount of $40,829.29. Page 5502 of 6526 28. Accordingly, RTS UNDERGROUND is liable to the County for the total sum of the losses to repair the damage caused by RTS UNDERGROUND. 29. All conditions precedent to the relief demanded herein have been performed or waived. COUNT I – NEGLIGENCE Wastewater Force Main Damage located at 3313 Europa Drive. 30. The County re-alleges and incorporates by reference its allegations in paragraphs 1–28, as if fully set forth herein. 31. RTS UNDERGROUND had a duty to notify the System and provide information about their planned excavation at least two full business days before beginning any excavation. Fla. Stat. § 556.105(1). 32. RTS UNDERGROUND breached the aforementioned duty by failing to notify the System pursuant to Section 556.105(1), Florida Statutes. 33. RTS UNDERGROUND’s breach of its duty to notify the System is the direct, proximate, and foreseeable result of the damage caused to the County’s owned, operated, and maintained wastewater force main located at 3313 Europa Drive. 34. In addition, should a member operator not mark its utilities, the Act imposes a duty on excavators to proceed only “if the excavator does so with reasonable care and if detection equipment or other acceptable means to locate underground facilities are used.” Fla. Stat. § 556.105(6)(a). 35. RTS UNDERGROUND had a duty to use increased caution to use reasonable care and locate the County’s wastewater force main located at 3313 Europa Drive. Page 5503 of 6526 36. RTS UNDERGROUND breached the aforementioned duty by failing to use reasonable care and failing to locate the County’s wastewater force main located at 3313 Europa Drive. 37. RTS UNDERGROUND’s breach of its duty to use reasonable care and failing to locate the County’s wastewater force main before proceeding with the excavation is the direct, proximate, and foreseeable result of the damage caused to the County’s wastewater force main. 38. Finally, RTS UNDERGROUND had a duty to exercise due care in the performance of its excavation at 3313 Europa Drive, which required RTS UNDERGROUND to exercise the degree of care that a reasonably careful excavator would use under like circumstances. 39. RTS UNDERGROUND breached its duty to exercise due care in the performance of its excavation at 3313 Europa Drive, in the following ways: a. RTS UNDERGROUND knew or should have known that the County had utilities in the vicinity of the proposed excavation. b. RTS UNDERGROUND failed to use the System altogether to provide information about its planned excavation at least two full business days before beginning any excavation. Fla. Stat. § 556.105(1). c. RTS UNDERGROUND ignored the County’s positive 3N response requesting that the proposed excavation be white lined. See Fla. Stat. § 556.114(3). d. RTS UNDERGROUND failed to coordinate with the County and provide additional information or a white line of the proposed excavation. e. RTS UNDERGROUND performed an excavation by directionally drilling underneath the ground without first locating the County’s wastewater force main or coordinating the excavation with the County. Page 5504 of 6526 40. The damage caused to the County’s wastewater force main was the direct, proximate, and foreseeable result of RTS UNDERGROUND’s malfeasance described in Paragraph 38, a.– e. 41. As a result of RTS UNDERGROUND’s negligence, the County incurred monetary damages including, but not limited to, $6,217.41 incurred by the County to repair the wastewater force main, and other direct and consequential damages. 42. RTS UNDERGROUND is liable to the County for the total sum of the losses incurred by the County as a result of its negligence. Fla. Stat. § 556.106(2)(b). WHEREFORE, the County demands judgment against Defendant, RTS OF BROWARD CORP., d/b/a RTS UNDERGROUND, for damages, together with prejudgment interest and costs, and for such other or further relief as this Court deems equitable and just under the circumstances. COUNT II – NEGLIGENCE Sewer Lateral Damage at 109, 124, and 215 Willowick Drive. 43. The County re-alleges and incorporates by reference its allegations in paragraphs 1–28, as if fully set forth herein. 44. “Obtaining information as to the location of an underground facility from the member operator as required by this chapter does not excuse any excavator from performing an excavation or demolition in a careful and prudent manner, based on accepted engineering and construction practices, and it does not excuse the excavator from liability for any damage or injury resulting from any excavation or demolition.” Fla. Stat. § 556.106(2)(c). 45. The Act imposes a duty on excavators to perform excavations in a careful and prudent manner, based on accepted engineering and construction practices. Fla. Stat. § 556.106(2)(c). Page 5505 of 6526 46. RTS UNDERGROUND had a duty to perform its excavation at 109, 124, and 215 Willowick Drive in a careful and prudent manner, based on accepted engineering and construction practices. 47. RTS UNDERGROUND breached this duty by failing to perform its excavation in a careful and prudent manner, based on accepted engineering and construction practices. 48. RTS UNDERGROUND’s breach of its duty to perform its excavation in a careful and prudent manner is the direct, proximate, and foreseeable result of the damage caused to the County’s sewer laterals at 109, 124, and 215 Willowick Drive. 49. In addition, the Act imposes a duty on excavators to use increased caution to identify and protect underground facilities when an excavation is to take place within a “tolerance zone.” Fla. Stat. § 556.105(5)(c). “The protection requires hand digging, pot holing, soft digging, vacuum excavation methods, or similar procedures to identify underground facilities.” Id. 50. The Act defines “tolerance zone” as “24 inches from the outer edge of either side of the exterior surface of a marked underground facility.” Fla. Stat. § 556.102(15). 51. RTS UNDERGROUND’s excavation at 109, 124, and 215 Willowick Drive was within the “tolerance zone” of the County’s sewer laterals. 52. RTS UNDERGROUND knew or should have known that its excavation was within the “tolerance zone” of the County’s sewer laterals, of which the County’s sewer laterals were marked prior to the excavation work. 53. RTS UNDERGROUND had a duty to use increased caution to identify and protect the County’s sewer laterals. Page 5506 of 6526 54. RTS UNDERGROUND breached this duty by failing to use increased caution to identify and protect the County’s sewer laterals before proceeding with its excavation at 109, 124, and 215 Willowick Drive. 55. The damage caused to the County’s sewer laterals was the direct, proximate, and foreseeable result of RTS UNDERGROUND’s breach of its duty to use increased caution to identify and protect the County’s sewer laterals within the tolerance zone. 56. Finally, RTS UNDERGROUND had a duty to exercise due care in the performance of its excavation at 109, 124, and 215 Willowick Drive, which required RTS UNDERGROUND to exercise the degree of care that a reasonably careful excavator would use under like circumstances. 57. RTS UNDERGROUND breached its duty to exercise due care in the performance of its excavation at 109, 124, and 215 Willowick Drive because RTS UNDERGROUND knew or should have known that the County had utilities in the vicinity of the proposed excavation. 58. The damage caused to the County’s sewer laterals was the direct, proximate, and foreseeable result of RTS UNDERGROUND’s breach. 59. As a result of RTS UNDERGROUND’s negligence, the County incurred monetary damages including, but not limited to, $34,611.88 incurred by the County to repair the sewer laterals, and other direct and consequential damages. 60. RTS UNDERGROUND is liable to the County for the total sum of the losses incurred by the County as a result of its negligence. Fla. Stat. § 556.106(2)(b). WHEREFORE, the County demands judgment against Defendant, RTS OF BROWARD CORP., d/b/a RTS UNDERGROUND, for damages, together with prejudgment interest and costs, and for such other or further relief as this Court deems equitable and just under the circumstances. Page 5507 of 6526 DEMAND FOR JURY TRIAL The County hereby demands a jury trial on all issues so triable. Respectfully submitted, By: _____________________________ Ronald T. Tomasko Florida Bar No. 1030999 Courtney L. DaSilva Florida Bar No. 1032733 Collier County Attorney’s Office 3299 East Tamiami Trail, Suite 800 Naples, Florida 34112-5746 Telephone: (239) 252-8400 Facsimile: (239) 252-6300 Counsel for Plaintiff COLLIER COUNTY ronald.tomasko@colliercountyfl.gov courtney.dasilva@colliercountyfl.gov nancy.bradley@colliercountyfl.gov rosa.villarreal@colliercountyfl.gov Page 5508 of 6526 September 29, 2023 RTS Underground Sent via email to - 'nfigueroa@rtsunderground.com' RE: Claim Number: 1158094 Claimant: Wastewater Collections Date of Loss: 11/13/2022 Our Client: Collier County PROP & AUTO PHYS Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $11,414.40 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5509 of 6526 October 24, 2023 RTS Underground 1410 20th St Miami Beach, FL 33139 RE: Claim Number: 1158094 Claimant: Wastewater Collections Date of Loss: 11/13/2022 Our Client: Collier County PROP & AUTO PHYS Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $11,414.40 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. John Barnett, ACA TPA P&C Adjuster Johns Eastern Company, Inc. Phone: 877.326.5326 x4229 Fax: 813.402.7922 Email: jbarnett@johnseastern.com PO Box 110239 Lakewood Ranch, FL 34211 www.johnseastern.com Page 5510 of 6526 From:Tammy Ludwig To:RodgersOliver Subject:RE: inv 5117 po 4500219576 rec 897382 Date:Thursday, December 8, 2022 10:43:30 AM EXTERNAL EMAIL: This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Oliver, Sorry for the mistake. Please short pay us $510.00 for my miscalculation. Tammy Ludwig Office Manager Douglas N. Higgins, Inc. 4485 Enterprise Ave. Naples, FL 34104 Phone: (239) 774-3130 Fax: (239) 774-4266 Email: tammyl@dnhiggins.com From: RodgersOliver <Oliver.Rodgers@colliercountyfl.gov> Sent: Thursday, December 8, 2022 10:37 AM To: Tammy Ludwig <tammyl@dnhiggins.com> Subject: inv 5117 po 4500219576 rec 897382 Importance: High Hello Tammy, The invoice has an amount of $680 for the Super that worked 2 hours. Please allow us to short pay the invoice by $510.00 in the amount of $10904.40. Thank you. E. Oliver Rodgers Accounting Technician Public Utilities Financial Operations Tel. (239)252-5340 3339 Tamiami Trail E. Suite #305 Naples, FL 34112 This email is copyrighted and any rebroadcast, retransmission, pictures, descriptions, or accounts of this email without the express written consent of Major League Baseball or the Los Angeles Dodgers is prohibited. Page 5511 of 6526 Under Florida Law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Page 5512 of 6526 CPW592 03802 CALL SUNSHINE 08/17/22 08:44:42ET 229200967-000 STREET Ticket : 229200967 Rev:000 Taken: 08/17/22 08:44ET State: FL Cnty: COLLIER GeoPlace: NAPLES CallerPlace: NAPLES Subdivision: Address : 103 to 127 Street : WILLOWICK DR Cross 1 : EUCLID AVE Within 1/4 mile: Y Locat: LOCATE ENTIRE PROPERTY AT 103 109 119 123 127 WILLOWICK DR INCLUDING ALL R/O/W'S AND EASEMENTS : Remarks : *** LOOKUP BY ADDRESS *** : Grids : 2616A8145A 2616A8145B Work date: 08/19/22 Time: 23:59ET Hrs notc: 063 Category: 3 Duration: 02 MONS Due Date : 08/19/22 Time: 23:59ET Exp Date : 09/16/22 Time: 23:59ET Work type: DIRECTIONAL DRILLING Boring: Y White-lined: Y Ug/Oh/Both: U Machinery: Y Depth: 10 FT Permits: Y PRROW2022041728301 Done for : FPL Company : RTS UNDERGROUND Type: CONT Co addr : 16051 BLATT BLVD Co addr2: SUITE 111 City : WESTON State: FL Zip: 33326 Caller : ANTONIO LEON Phone: 954-610-6187 Contact : ANTONIO LEON Phone: 813-484-9460 BestTime: 7AM-5PM Mobile : 813-484-9460 Email : INFO@RTSUNDERGROUND.COM Submitted: 08/17/22 08:44ET Oper: BOB Mbrs : CNTL01 CPW592 CTV413 FPLCLR 8/17/2022 8:44:42 AM: Received DETAILS: Ticket received for registration code CPW592 8/17/2022 8:44:42 AM: Assigned DETAILS: Assigned to Rolando Vivo by auto process NOTE: Auto Processed per Responsibility Area 8/17/2022 8:44:42 AM: Ticket Queued DETAILS: Ticket queued for delivery 8/17/2022 8:44:47 AM: Ticket Delivered DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 8/18/2022 1:07:33 PM: Responded Page 5513 of 6526 DETAILS: 2E: added by Rolando Vivo, Locate Time: 8/18/2022 1:07:33 PM NOTE: water main/ services sewer lats gravity main 8/18/2022 1:07:33 PM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 8/18/2022 1:07:39 PM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5514 of 6526 COLLIER COUNTY UTILITY DAMAGE INVESTIGATION REPORT EVENT INFORMATION INVESTIGATED BY: DENNIS DANIELS DATE OF INCIDENT: 11/14/22 TIME OF INCIDENT: 12:00 AM ADDRESS: 109 Willowick Dr CROSS STREET: Choose an item. CONTRACTOR NAME: RTS Underground CONTACT PHONE: 813-484-9460 CONTACT NAME: ANTONIO LEON TICKET INFORMATION TICKET NUMBERS: 229200967 Choose an item. Choose an item. TICKET DUE DATE: 8/19/22 TICKET EXPIRATION: 9/16/22 WAS THE TICKET VALID: YES LAST RESPONSE CODE: 2E - MARKED - PER WHITE LINE WAS 811 NOTIFIED: YES IF NO, ARE THEY EXEMPT: Choose an item. FACILITY AND EXCAVATION INFORMATION TYPE OF DAMAGE: UNDERGROUND DAMAGE FACILITY DAMGED: SEWER TYPE OF FACILITY: GATHERING CROSS BORE: YES DEPTH OF DAMAGE: 18" - 36" TYPE OF EXCAVATOR: CONTRACTOR EXCAV EQUIPMENT: BORING TYPE OF WORK: ELECTRIC TYPE OF LOCATOR: Choose an item. WHITE LINED: YES RIGHT OF WAY: COUNTY ROAD MEMBER OPERATOR: Choose an item. DOWNTIME, INTERUPTION AND RESTORATION EXCAVATOR DOWN TIME: NO IF YES, HOW MUCH: Choose an item. DOWN TIME COST: Choose an item. SERVICE INTERUPTION: YES INTERUPTION DURATION: N/A CUSTOMERS AFFECTED: 0 EST COST OF REPAIRS: UNKNOWN ROOT CAUSE ROOT CAUSE: EXCAVATOR DUG PRIOR TO VERIFYING MARKS BY TEST-HOLE (POT-HOLE) WERE UTILITIES SPOTTED: UNKNOWN WAS CONT 556 COMPLIANT: NO WHO LOCATED: ROLANDO VIVO DIRT NUMBER: Choose an item. CITATION ISSUED: Choose an item. CITATION #: Choose an item. FIELD OBSERVATIONS: Collections discovered utilities were bored through by conduit. utilities were Located and no attempt was made by RTS Underground to spot utilities. PREPARED BY: DENNIS DANIELS DATE PREPARED: 11/14/22 Page 5515 of 6526 Page 5516 of 6526 Page 5517 of 6526 Page 5518 of 6526 Page 5519 of 6526 Page 5520 of 6526 Page 5521 of 6526 Page 5522 of 6526 Page 5523 of 6526 Page 5524 of 6526 Page 5525 of 6526 Page 5526 of 6526 Page 5527 of 6526 Page 5528 of 6526 Page 5529 of 6526 Page 5530 of 6526 Page 5531 of 6526 Page 5532 of 6526 Page 5533 of 6526 Page 5534 of 6526 Page 5535 of 6526 Page 5536 of 6526 Page 5537 of 6526 June 08, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142115 Claimant: Wastewater Division Date of Loss: 09/25/2022 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $8,513.38 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5538 of 6526 July 26, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142115 Claimant: Wastewater Division Date of Loss: 09/25/2022 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We attempted to deliver a subrogation demand to this address, but were unsuccessful. A subrogation demand was emailed, as well. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $8,513.38 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5539 of 6526 COLLIER COUNTY UTILITY DAMAGE INVESTIGATION REPORT EVENT INFORMATION INVESTIGATED BY: DENNIS DANIELS DATE OF INCIDENT: 11/10/22 TIME OF INCIDENT: 12:00 AM ADDRESS: 124 Willowick Dr CROSS STREET: Turnbury Way CONTRACTOR NAME: RTS Underground CONTACT PHONE: 813-484-9460 CONTACT NAME: ANTONIO LEON TICKET INFORMATION TICKET NUMBERS: 226200160 Choose an item. Choose an item. TICKET DUE DATE: 8/16/22 TICKET EXPIRATION: 9/13/22 WAS THE TICKET VALID: YES LAST RESPONSE CODE: 2E - MARKED - PER WHITE LINE WAS 811 NOTIFIED: YES IF NO, ARE THEY EXEMPT: Choose an item. FACILITY AND EXCAVATION INFORMATION TYPE OF DAMAGE: UNDERGROUND DAMAGE FACILITY DAMGED: SEWER TYPE OF FACILITY: GATHERING CROSS BORE: YES DEPTH OF DAMAGE: 18" - 36" TYPE OF EXCAVATOR: CONTRACTOR EXCAV EQUIPMENT: BORING TYPE OF WORK: ELECTRIC TYPE OF LOCATOR: FACILITY OWNER WHITE LINED: YES RIGHT OF WAY: COUNTY ROAD MEMBER OPERATOR: Choose an item. DOWNTIME, INTERUPTION AND RESTORATION EXCAVATOR DOWN TIME: NO IF YES, HOW MUCH: UNKNOWN DOWN TIME COST: UNKNOWN SERVICE INTERUPTION: YES INTERUPTION DURATION: N/A CUSTOMERS AFFECTED: 0 EST COST OF REPAIRS: UNKNOWN ROOT CAUSE ROOT CAUSE: EXCAVATOR DUG PRIOR TO VERIFYING MARKS BY TEST-HOLE (POT-HOLE) WERE UTILITIES SPOTTED: NO WAS CONT 556 COMPLIANT: NO WHO LOCATED: ROLANDO VIVO DIRT NUMBER: Choose an item. CITATION ISSUED: Choose an item. CITATION #: Choose an item. FIELD OBSERVATIONS: Collections discovered utilities were bored through by conduit. utilities were Located and no attempt was made by RTS Underground to spot utilities. PREPARED BY: DENNIS DANIELS DATE PREPARED: 11/10/22 Page 5540 of 6526 CPW592 00560 CALL SUNSHINE 08/14/22 13:36:05ET 226200160-000 STREET Ticket : 226200160 Rev:000 Taken: 08/14/22 13:35ET State: FL Cnty: COLLIER GeoPlace: NAPLES CallerPlace: NAPLES Subdivision: Address : Street : WILLOWICK DR Cross 1 : TURNBURY WAY Within 1/4 mile: Y Cross 2 : LAKELAND AVE Locat: LOCATE N AND S SIDE OF WILLOWICK DR BETWEEN TURNBURY WAY AND LAKELAND AVE, TO INCL ALL RD CROSSING. : Remarks : FPL SECURE STORM UNDERGROUND PROGRAM *** LOOKUP BY BETWEEN *** : Grids : 2616A8145B 2616A8145C Work date: 08/16/22 Time: 23:59ET Hrs notc: 040 Category: 3 Duration: 01 MON Due Date : 08/16/22 Time: 23:59ET Exp Date : 09/13/22 Time: 23:59ET Work type: U/G BORING Boring: Y White-lined: Y Ug/Oh/Both: U Machinery: Y Depth: 36 IN Permits: Y N/A Done for : FPL SSUP Company : RTS UNDERGROUND Type: CONT Co addr : 16051 BLATT BLVD Page 5541 of 6526 Co addr2: SUITE 111 City : WESTON State: FL Zip: 33326 Caller : ANABEL ALOMAR Phone: 954-610-6187 Contact : ANTONIO LEON Phone: 813-484-9460 BestTime: ANYTIME Mobile : 813-484-9460 Email : INFO@RTSUNDERGROUND.COM Submitted: 08/14/22 13:35ET Oper: ANA Chan: WEB Mbrs : CNTL01 CPW592 CTV413 FPLCLR 8/14/2022 1:36:05 PM: Received DETAILS: Ticket received for registration code CPW592 8/14/2022 1:36:05 PM: Assigned DETAILS: Assigned to Rolando Vivo by auto process NOTE: Auto Processed per Responsibility Area 8/14/2022 1:36:05 PM: Ticket Queued DETAILS: Ticket queued for delivery 8/14/2022 1:36:08 PM: Ticket Delivered DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 8/16/2022 1:22:16 PM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 8/16/2022 1:22:16 PM: Responded DETAILS: 8 (Ongoing): added by Rolando Vivo, Locate Time: 8/16/2022 1:22:15 PM Page 5542 of 6526 NOTE: Spoke with Sergio ( 954-610-6187) we agreed mark utilities as needed. 8/16/2022 1:22:26 PM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent 8/23/2022 10:05:25 AM: Note Added DETAILS: Note added by Rolando Vivo NOTE: Marked water main/ services gravity main sewer lats force main Pictures: 226200160 8/23/2022 10:06:09 AM: Responded DETAILS: 2E: added by Rolando Vivo, Locate Time: 8/23/2022 10:06:09 AM NOTE: Marked water main/ services gravity main sewer lats force main Pictures: 226200160 8/23/2022 10:06:09 AM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 8/23/2022 10:06:13 AM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5543 of 6526 June 08, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142118 Claimant: Wastewater Division Date of Loss: 10/16/2022 Our Client: Collier County BOCC Dear RTS Underground : Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $14,684.10 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5544 of 6526 July 26, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142118 Claimant: Wastewater Division Date of Loss: 10/16/2022 Our Client: Collier County BOCC Dear RTS Underground : Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We attempted to deliver a subrogation demand to this address, but were unsuccessful. A subrogation demand was emailed, as well. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $14,684.10 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5545 of 6526 COLLIER COUNTY UTILITY DAMAGE INVESTIGATION REPORT EVENT INFORMATION INVESTIGATED BY: DENNIS DANIELS DATE OF INCIDENT: 11/10/22 TIME OF INCIDENT: 12:00 AM ADDRESS: 215 Willowick Dr CROSS STREET: Choose an item. CONTRACTOR NAME: : RTS UNDERGROUND CONTACT PHONE: 813-484-9460 CONTACT NAME: ANTONIO LEON TICKET INFORMATION TICKET NUMBERS: UNKNOWN Choose an item. Choose an item. TICKET DUE DATE: 8/19/22 TICKET EXPIRATION: 9/16/22 WAS THE TICKET VALID: YES LAST RESPONSE CODE: 2E - MARKED - PER WHITE LINE WAS 811 NOTIFIED: YES IF NO, ARE THEY EXEMPT: Choose an item. FACILITY AND EXCAVATION INFORMATION TYPE OF DAMAGE: UNDERGROUND DAMAGE FACILITY DAMGED: SEWER TYPE OF FACILITY: GATHERING CROSS BORE: YES DEPTH OF DAMAGE: 18" - 36" TYPE OF EXCAVATOR: CONTRACTOR EXCAV EQUIPMENT: BORING TYPE OF WORK: ELECTRIC TYPE OF LOCATOR: FACILITY OWNER WHITE LINED: YES RIGHT OF WAY: CITY STREET MEMBER OPERATOR: YES DOWNTIME, INTERUPTION AND RESTORATION EXCAVATOR DOWN TIME: NO IF YES, HOW MUCH: Choose an item. DOWN TIME COST: Choose an item. SERVICE INTERUPTION: YES INTERUPTION DURATION: N/A CUSTOMERS AFFECTED: 0 EST COST OF REPAIRS: UNKNOWN ROOT CAUSE ROOT CAUSE: EXCAVATOR DUG PRIOR TO VERIFYING MARKS BY TEST-HOLE (POT-HOLE) WERE UTILITIES SPOTTED: NO WAS CONT 556 COMPLIANT: NO WHO LOCATED: ROLANDO VIVO DIRT NUMBER: Choose an item. CITATION ISSUED: NO CITATION #: Choose an item. FIELD OBSERVATIONS: Collections discovered utilities were bored through by conduit. utilities were Located and no attempt was made by RTS Underground to spot utilities that we can see. PREPARED BY: DENNIS DANIELS DATE PREPARED: 11/10/22 Page 5546 of 6526 Page 5547 of 6526 Page 5548 of 6526 Page 5549 of 6526 Page 5550 of 6526 Page 5551 of 6526 CPW592 04034 CALL SUNSHINE 08/17/22 08:50:48ET 229201045-000 STREET Ticket : 229201045 Rev:000 Taken: 08/17/22 08:50ET State: FL Cnty: COLLIER GeoPlace: NAPLES CallerPlace: NAPLES Subdivision: Address : 215 to 239 Street : WILLOWICK DR Cross 1 : EUCLID AVE Within 1/4 mile: Y Locat: LOCATE ENTIRE PROPERTY AT 215 223 229 235 239 WILLOWICK DR INCLUDING ALL R/O/W'S AND EASEMENTS : Remarks : *** LOOKUP BY ADDRESS *** : Grids : 2616A8145B 2616A8145C Work date: 08/19/22 Time: 23:59ET Hrs notc: 063 Category: 3 Duration: 02 MONS Due Date : 08/19/22 Time: 23:59ET Exp Date : 09/16/22 Time: 23:59ET Work type: DIRECTIONAL DRILLING Boring: Y White-lined: Y Ug/Oh/Both: U Machinery: Y Depth: 10 FT Permits: Y PRROW2022041728301 Done for : FPL Company : RTS UNDERGROUND Type: CONT Co addr : 16051 BLATT BLVD Co addr2: SUITE 111 City : WESTON State: FL Zip: 33326 Page 5552 of 6526 Caller : ANTONIO LEON Phone: 954-610-6187 Contact : ANTONIO LEON Phone: 813-484-9460 BestTime: 7AM-5PM Mobile : 813-484-9460 Email : INFO@RTSUNDERGROUND.COM Submitted: 08/17/22 08:50ET Oper: BOB Mbrs : CNTL01 CPW592 CTV413 FPLCLR 8/17/2022 8:50:48 AM: Received DETAILS: Ticket received for registration code CPW592 8/17/2022 8:50:48 AM: Assigned DETAILS: Assigned to Rolando Vivo by auto process NOTE: Auto Processed per Responsibility Area 8/17/2022 8:50:48 AM: Ticket Queued DETAILS: Ticket queued for delivery 8/17/2022 8:50:52 AM: Ticket Delivered DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 8/18/2022 2:38:45 PM: Responded DETAILS: 8 (Ongoing): added by Rolando Vivo, Locate Time: 8/18/2022 2:38:45 PM NOTE: Spoke with Sergio ( 954-610-6187) we agreed mark utilities as needed. 8/18/2022 2:38:45 PM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 8/18/2022 2:38:55 PM: Positive Response to Center Delivered Page 5553 of 6526 DETAILS: Positive Response to Center successfully sent 8/23/2022 10:05:25 AM: Note Added DETAILS: Note added by Rolando Vivo NOTE: Marked water main/ services gravity main sewer lats force main Pictures: 226200160 8/23/2022 10:06:10 AM: Responded DETAILS: 2E: added by Rolando Vivo, Locate Time: 8/23/2022 10:06:09 AM NOTE: Marked water main/ services gravity main sewer lats force main Pictures: 226200160 8/23/2022 10:06:10 AM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 8/23/2022 10:06:14 AM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5554 of 6526 June 08, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142128 Claimant: Wastewater Division Date of Loss: 12/12/2022 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $15,451.39 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5555 of 6526 July 26, 2023 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1142128 Claimant: Wastewater Division Date of Loss: 12/12/2022 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates you are responsible for the above referenced loss. We attempted to deliver a subrogation demand to this address, but were unsuccessful. A subrogation demand was emailed, as well. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $15,451.39 Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Grace Kitchner Grace Kitchner Phone: (941) 907-3100 4167 Email: gkitchner@johnseastern.com Page 5556 of 6526 COLLIER COUNTY UTILITY DAMAGE INVESTIGATION REPORT EVENT INFORMATION INVESTIGATED BY: DENNIS DANIELS DATE OF INCIDENT: 12/12/22 TIME OF INCIDENT: 12:00 AM ADDRESS: 2285 41st Terrace SW CROSS STREET: 22nd Ave SW CONTRACTOR NAME: RTS Underground CONTACT PHONE: 786-252-6664 CONTACT NAME: Ronald Batista TICKET INFORMATION TICKET NUMBERS: 311203274 Choose an item. Choose an item. TICKET DUE DATE: 11/9/22 TICKET EXPIRATION: 12/7/22 WAS THE TICKET VALID: YES LAST RESPONSE CODE: 8 - ONGOING JOB WAS 811 NOTIFIED: YES IF NO, ARE THEY EXEMPT: Choose an item. FACILITY AND EXCAVATION INFORMATION TYPE OF DAMAGE: UNDERGROUND DAMAGE FACILITY DAMGED: SEWER TYPE OF FACILITY: GATHERING CROSS BORE: YES DEPTH OF DAMAGE: 18" - 36" TYPE OF EXCAVATOR: CONTRACTOR EXCAV EQUIPMENT: BORING TYPE OF WORK: ELECTRIC TYPE OF LOCATOR: FACILITY OWNER WHITE LINED: YES RIGHT OF WAY: COUNTY ROAD MEMBER OPERATOR: Choose an item. DOWNTIME, INTERUPTION AND RESTORATION EXCAVATOR DOWN TIME: NO IF YES, HOW MUCH: Choose an item. DOWN TIME COST: Choose an item. SERVICE INTERUPTION: YES INTERUPTION DURATION: N/A CUSTOMERS AFFECTED: 1 EST COST OF REPAIRS: UNKNOWN ROOT CAUSE ROOT CAUSE: FACILITY NOT MARKED DUE TO LOCATOR ERROR WERE UTILITIES SPOTTED: NO WAS CONT 556 COMPLIANT: Choose an item. WHO LOCATED: MACKENZIE PIERRE DIRT NUMBER: Choose an item. CITATION ISSUED: NO CITATION #: Choose an item. FIELD OBSERVATIONS: Upon final inspection Pierre Mackenzie failed to locate Collier County’s utilities (sewer lateral, water service) at the property of 2285 41 Ter SW. Pierre failed to locate per Collier County Stakes and Locates SOP 2. The water main was located. PREPARED BY: DENNIS DANIELS DATE PREPARED: 12/14/22 Page 5557 of 6526 Page 5558 of 6526 Page 5559 of 6526 Page 5560 of 6526 Page 5561 of 6526 Page 5562 of 6526 Page 5563 of 6526 Page 5564 of 6526 Page 5565 of 6526 Page 5566 of 6526 CPW592 09780 CALL SUNSHINE 11/07/22 11:06:31ET 311203274-000 STREET Ticket : 311203274 Rev:000 Taken: 11/07/22 11:06ET State: FL Cnty: COLLIER GeoPlace: GOLDEN GATE CallerPlace: GOLDEN GATE Subdivision: Address : 2264 to 2300 Street : 41ST TER SW Cross 1 : 22ND AVE SW Within 1/4 mile: Y Locat: LOCATE ALL EASEMENT R/O/W AND SERVICES OF PROPERTIES 2264, 2271, 2280, 2285 AND 2300 41ST TER SW, TO INCL ALL RD CROSSING. : Remarks : FPL SECURE STORM UNDERGROUND PROGRAM 11/07/2022 11:06:16 AM CNTL01 HAS DECLARED EXTRAORDINARY CIRCUMSTANCES *** LOOKUP BY ADDRESS *** : Grids : 2611C8141C 2611D8141C Work date: 11/09/22 Time: 23:59ET Hrs notc: 060 Category: 3 Duration: 01 MON Due Date : 11/09/22 Time: 23:59ET Exp Date : 12/07/22 Time: 23:59ET Work type: U/G BORING Boring: Y White-lined: Y Ug/Oh/Both: U Machinery: Y Depth: 36 IN Permits: Y N/A Done for : FPL SSUP Company : RTS UNDERGROUND Type: CONT Co addr : 16051 BLATT BLVD Co addr2: SUITE 111 City : WESTON State: FL Zip: 33326 Caller : ANABEL ALOMAR Phone: 954-610-6187 Contact : RONALD BATISTA Phone: 786-252-6664 BestTime: ANYTIME Mobile : 786-252-6664 Email : INFO@RTSUNDERGROUND.COM Submitted: 11/07/22 11:06ET Oper: ANA Chan: WEB Mbrs : CC1255 CC1650 CC2156 CNTL01 CON762 CPW592 FPLCLR NN1882 PGSSW 11/7/2022 11:06:31 AM: Received DETAILS: Ticket received for registration code CPW592 11/7/2022 11:06:31 AM: Assigned DETAILS: Assigned to Mackenzie Pierre by auto process NOTE: Auto Processed per Responsibility Area 11/7/2022 11:06:32 AM: Ticket Queued DETAILS: Ticket queued for delivery Page 5567 of 6526 11/7/2022 11:06:43 AM: Ticket Delivered DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 11/8/2022 11:28:16 AM: Responded DETAILS: 8: added by Mackenzie Pierre, Locate Time: 11/8/2022 11:28:15 AM NOTE: ongoing project spoke with Ronald 11/8/22 @ 9:43 am they will be starting Friday the 11th 23rd ave sw. Will be working with crews and staying ahead with locates. 11/8/2022 11:28:16 AM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 11/8/2022 11:28:20 AM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5568 of 6526 CPW592 19370 CALL SUNSHINE 12/12/22 15:24:22ET 346206637-000 EMERGENCY STREET Ticket : 346206637 Rev:000 Taken: 12/12/22 15:24ET State: FL Cnty: COLLIER GeoPlace: GOLDEN GATE CallerPlace: GOLDEN GATE Subdivision: Address : 2285 Street : 41ST TER SW Cross 1 : 22ND AVE SW Within 1/4 mile: Y Locat: LOCATE THE DRIVEWAY AT 2285 41ST TER SW : Remarks : CREW EN ROUTE. COLLIER COUNTY ON SITE. EMERGENCY: PROTECT LIFE OR PROPERTY *** THIS TICKET WAS CREATED AS THE RESULT OF A DAMAGE *** LOOKUP BY ADDRESS *** : Grids : 2611C8141C 2611D8141C Work date: 12/12/22 Time: 15:22ET Hrs notc: 000 Category: 1 Duration: 01 DAY Due Date : 12/12/22 Time: 15:22ET Exp Date : 01/11/23 Time: 23:59ET Work type: SEWER LATERAL REPAIR Boring: N White-lined: N Ug/Oh/Both: U Machinery: Y Depth: 4 FT Permits: N N/A Done for : COLLIER COUNTY Company : KYLE CONSTRUCTION Type: CONT Co addr : 3636 PROSPECT AVE Co addr2: 3636 PROSPECT AVE City : NAPLES State: FL Zip: 34104-3752 Caller : KYLE ABRAHAM Phone: 239-643-7059 Contact : KYLE ABRAHAM Phone: 239-595-0438 BestTime: 7AM-5PM Mobile : 239-595-0438 Fax : 239-643-4679 Email : KYLECONSTINC@AOL.COM Submitted: 12/12/22 15:24ET Oper: KYL Chan: WEB Mbrs : CC1255 CC1650 CC2156 CNTL01 CON762 CPW592 FPLCLR NN1882 PGSSW 12/12/2022 3:24:22 PM: Received DETAILS: Ticket received for registration code CPW592 12/12/2022 3:24:22 PM: Assigned DETAILS: Assigned to Mackenzie Pierre by auto process NOTE: Auto Processed per Responsibility Area 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued Page 5569 of 6526 DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:22 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/12/2022 3:24:32 PM: Ticket Delivered DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 12/12/2022 3:24:33 PM: Ticket Delivered DETAILS: Ticket successfully sent to Dennis.Daniels@colliercountyfl.gov 12/12/2022 3:24:33 PM: Ticket Delivered DETAILS: Ticket successfully sent to Paul.Carbone@colliercountyfl.gov 12/12/2022 3:24:33 PM: Ticket Delivered DETAILS: Ticket successfully sent to Mackenzie.Pierre@colliercountyfl.gov 12/12/2022 3:24:33 PM: Ticket Delivered DETAILS: Ticket successfully sent to Justin.Williams@colliercountyfl.gov 12/12/2022 3:24:34 PM: Ticket Delivered DETAILS: Ticket successfully sent to Jory.Bekich@colliercountyfl.gov 12/12/2022 3:24:34 PM: Ticket Delivered DETAILS: Ticket successfully sent to Zachary.Bekich@colliercountyfl.gov 12/12/2022 3:24:34 PM: Ticket Delivered DETAILS: Ticket successfully sent to Rolando.Vivo@colliercountyfl.gov 12/12/2022 3:24:35 PM: Ticket Delivered Page 5570 of 6526 DETAILS: Ticket successfully sent to Steve.Chandler@colliercountyfl.gov 12/12/2022 3:24:35 PM: Ticket Delivered DETAILS: Ticket successfully sent to Daniela.Mercado@colliercountyfl.gov 12/12/2022 3:24:35 PM: Ticket Delivered DETAILS: Ticket successfully sent to daniel.ybarra@colliercountyfl.gov 12/12/2022 5:25:33 PM: Re-Assigned DETAILS: Re-Assigned from Mackenzie Pierre to Daniel Ybarra by Daniel Ybarra 12/12/2022 5:35:39 PM: Responded DETAILS: 1: added by Daniel Ybarra, Locate Time: 12/12/2022 5:35:39 PM NOTE: Marked water main and sewer lateral. Used GPR and RD. No measurement on GGC sewer late from wastewater camera viewed it Kyle went with him marks 12/12/2022 5:35:39 PM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 12/12/2022 5:35:43 PM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5571 of 6526 CPW592 14169 CALL SUNSHINE 12/02/22 14:02:40ET 336204525-000 STREET Ticket : 336204525 Rev:000 Taken: 12/02/22 14:02ET Old Tkt: 311203274 Taken: 11/07/22 11:06ET Oper: ANA State: FL Cnty: COLLIER GeoPlace: GOLDEN GATE CallerPlace: GOLDEN GATE Subdivision: Address : 2264 to 2300 Street : 41ST TER SW Cross 1 : 22ND AVE SW Within 1/4 mile: Y Locat: LOCATE ALL EASEMENT R/O/W AND SERVICES OF PROPERTIES 2264, 2271, 2280, 2285 AND 2300 41ST TER SW, TO INCL ALL RD CROSSING. : Remarks : FPL SECURE STORM UNDERGROUND PROGRAM 11/07/2022 11:06:16 AM CNTL01 HAS DECLARED EXTRAORDINARY CIRCUMSTANCES THIS TICKET REPLACES TICKET #311203274 ANABEL.ALOMAR WEB 12/02/2022 2:02:07 PM *** LOOKUP BY ADDRESS *** : Grids : 2611C8141C 2611D8141C Work date: 12/06/22 Time: 23:59ET Hrs notc: 057 Category: 3 Duration: 01 MON Due Date : 12/06/22 Time: 23:59ET Exp Date : 01/03/23 Time: 23:59ET Work type: U/G BORING Boring: Y White-lined: Y Ug/Oh/Both: U Machinery: Y Depth: 36 IN Permits: Y N/A Done for : FPL SSUP Company : RTS UNDERGROUND Type: CONT Co addr : 16051 BLATT BLVD Co addr2: SUITE 111 City : WESTON State: FL Zip: 33326 Caller : ANABEL ALOMAR Phone: 954-610-6187 Contact : RONALD BATISTA Phone: 786-252-6664 BestTime: ANYTIME Mobile : 754-214-5427 Email : INFO@RTSUNDERGROUND.COM Submitted: 12/02/22 14:02ET Oper: ANA Chan: WEB Mbrs : CC1255 CC1650 CC2156 CNTL01 CON762 CPW592 FPLCLR NN1882 PGSSW 12/2/2022 2:02:40 PM: Received DETAILS: Ticket received for registration code CPW592 12/2/2022 2:02:40 PM: Assigned DETAILS: Assigned to Mackenzie Pierre by auto process NOTE: Auto Processed per Responsibility Area 12/2/2022 2:02:41 PM: Ticket Queued DETAILS: Ticket queued for delivery 12/2/2022 2:03:00 PM: Ticket Delivered Page 5572 of 6526 DETAILS: Ticket successfully sent to WWTS-IRTHNET@colliercountyfl.gov 12/2/2022 3:03:59 PM: Responded DETAILS: 8: added by Mackenzie Pierre, Locate Time: 12/2/2022 3:03:57 PM NOTE: ongoing ticket, Iam currently working with Daniel from RTS on where locates are needed 12/2/2022 3:03:59 PM: Positive Response to Center Queued DETAILS: Positive Response to Center queued for delivery 12/2/2022 3:04:03 PM: Positive Response to Center Delivered DETAILS: Positive Response to Center successfully sent Page 5573 of 6526 December 08, 2021 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1066837 Claimant: RTS Underground Date of Loss: 10/26/2021 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates your company was boring and damaged a wastewater force main in which is owned and maintained by Collier County. The County requests payment for their damages. We provide the attached supporting documentation for our subrogation demand. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $_6,217.41_______ Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Brandon Cooper Brandon Cooper TPA Liability Adjuster Phone: (941) 208-4233 Email: bcooper@johnseastern.com Page 5574 of 6526 Page 5575 of 6526 January 05, 2021 RTS Underground 1410 20th Street #204 Miami Beach, FL 33139 RE: Claim Number: 1066837 Claimant: RTS Underground Date of Loss: 10/26/2021 Our Client: Collier County BOCC Dear RTS Underground: Johns Eastern Company is the Third Party Administrator engaged to assist in the handling of the above-referenced claim. Our investigation indicates your company was boring and damaged a wastewater force main in which is owned and maintained by Collier County. The County requests payment for their damages. We ask that you issue a draft to: Collier County BOCC c/o Johns Eastern Company PO Box 110239 Lakewood Ranch, Florida 34211-0004 In the amount of, $_6,217.41_______ Please contact our office should you have any questions. Sincerely, Johns Eastern Company, Inc. Brandon Cooper Brandon Cooper TPA Liability Adjuster Phone: (941) 208-4233 Email: bcooper@johnseastern.com Page 5576 of 6526 [24-RMG-00833/1852858/1] COLLIER COUNTY UTILITY DAMAGE INVESTIGATION REPORT EVENT INFORMATION INVESTIGATED BY: STEPHEN CHANDLER DATE OF INCIDENT: 10/26/21 TIME OF INCIDENT: 2:30 PM ADDRESS: Corinthian Way CROSS STREET: Europa Dr. CONTRACTOR NAME: RTS UNDERGROUND CONTACT PHONE: 786-878-2188 CONTACT NAME: DAVID JARAMILLO TICKET INFORMATION TICKET NUMBERS: 291109548 Choose an item. Choose an item. TICKET DUE DATE: 10/20/21 TICKET EXPIRATION: 11/17/21 WAS THE TICKET VALID: NO LAST RESPONSE CODE: 3N - UNMARKED - WHITE LINE REQUIRED WAS 811 NOTIFIED: Choose an item. IF NO, ARE THEY EXEMPT: Choose an item. FACILITY AND EXCAVATION INFORMATION TYPE OF DAMAGE: UNDERGROUND DAMAGE FACILITY DAMGED: SEWER TYPE OF FACILITY: GATHERING CROSS BORE: NO DEPTH OF DAMAGE: 36" OR GREATER TYPE OF EXCAVATOR: CONTRACTOR EXCAV EQUIPMENT: DIRECTIONAL DRILLING TYPE OF WORK: CABLE TV TYPE OF LOCATOR: OTHER / UNKNOWN WHITE LINED: NO RIGHT OF WAY: COUNTY ROAD MEMBER OPERATOR: Choose an item. DOWNTIME, INTERUPTION AND RESTORATION EXCAVATOR DOWN TIME: UNKNOWN IF YES, HOW MUCH: UNKNOWN DOWN TIME COST: UNKNOWN SERVICE INTERUPTION: YES INTERUPTION DURATION: N/A CUSTOMERS AFFECTED: Choose an item. EST COST OF REPAIRS: UNKNOWN ROOT CAUSE ROOT CAUSE: ROOT CAUSE NOT LISTED ABOVE WERE UTILITIES SPOTTED: NO WAS CONT 556 COMPLIANT: NO WHO LOCATED: MACKENZIE PIERRE DIRT NUMBER: 6421766 CITATION ISSUED: NO CITATION #: Choose an item. FIELD OBSERVATIONS: The contractor RTS Underground directional drilled without having a ticket in the area of where they were working and the contractor did not check positive response, Mackenzie left the positive response of 3N Requesting white line of the projected bore path will be. If the contractor would have stayed compliant with FS 556 and checked positive response this damage could have been avoided. The contractor failed to follow the requirements of 556 and should be responsible for the damage. PREPARED BY: ANDREW BEKICH DATE PREPARED: 10/28/21 Page 5577 of 6526 [24-RMG-00833/1852858/1] Page 5578 of 6526 Page 5579 of 6526 Page 5580 of 6526 Page 5581 of 6526 Page 5582 of 6526 Date Approved: June 13, 2022 Right-of-Way Permit Number: PRROW2022041728301 SDP/AR/PSP Number: N/A Building Permit Number: N/A Project Name: FPL WR 8631059-Place underground Power and remove the overhead power Project Address: multiple locations crossing Euclid Ave on Willowic crossing Lakeland Ave., down Willowick Dr., and Turnbury Way Subdivision: Willoughby Acres Lot:Block:Unit:Tract: Folio No:Section: 24 Township: 48 Range: 25 ******************************************************************************************************************************************************************************** Type of Construction: ROW Commercial Detail: FPL WR 8631059-Place underground Power and remove the overhead power Multiple locations: crossing Euclid Ave on Willowick Dr to Turnbury Way and Lakeland Ave THIS PERMIT IS VALID FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ISSUANCE. Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Applicant: Troy Todd Florida Power & Light 1220 5th Ave N, Naples, FL 34102 Telephone Number: Contractor: Florida Power & Light 1220 5th Ave N, Naples, FL 34102 Telephone Number: 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: Before commencement of any excavation, the existing underground utilities in the area affected by the work must be marked by Sunshine One Call, in accordance with State Statute Chapter 556 “Underground Facility Damage Prevention and Safety”, after proper notification to them by either calling 811 in Florida or toll free at 1-800-432-4770. Visit www.callsunshine.com for more information. Before commencing excavation for the work, potholing of all potential conflicts must be performed. Condition: Sunshine 811 Damage Prevention Guide: Chapter 556, F.S., sets a tolerance zone that extends 24 inches from the outer edge of each side of an underground facility. Locate marks show the approximate location of an underground facility. To be sure where that facility is located, you must expose it using a method below:Hand digging at an angle toward the facilityPot holingSoft diggingVacuum excavation methodsOther similar proceduresExposing the facility lets you see the facility size and the clearance you need to maintain during excavation. Digging within the tolerance zone requires special precaution and using mechanized equipment requires a spotter. Within existing pavement, soft digging will be required after removal of pavement associated with a permitted open-cut. Condition: As Built Drawings are required prior to final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. You must be signed into the CityView Portal as a registered user to upload the document. Page 5583 of 6526 Condition: Work identified outside the limits of the right of way is not included in this Right of Way Permit approval. Condition: Please plan accordingly when scheduling inspections and schedule well in advance of when needed or permit expiration dates. Please call 239-252-3726 to schedule inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5584 of 6526 Date Approved: September 26, 2022 Right-of-Way Permit Number: PRROW2022052540101 SDP/AR/PSP Number: N/A Building Permit Number: N/A Project Name: FPL:42nd ST SW & 23rd AVE SW, then S to 23rd PL SW; 45th ST SW & 23rd AVE SW, then S to 23rd PL SW; 20th PL SW & 41st TE Project Address: 42nd St SW , 20th Pl SW, Subdivision: Golden Gate Lot:Block:Unit:Tract: Folio No:Section: 22 Township: 49 Range: 26 ******************************************************************************************************************************************************************************** Type of Construction: ROW Commercial Detail: FPL WR8932718 Modify Exiting Power poles, making them ready for going underground - installing brackets on existing poles no new poles proposed under this scope of work. 42nd ST SW & 23rd AVE SW, then S to 23rd PL SW; 45th ST SW & 23rd AVE SW, then S to 23rd PL SW; 20th PL SW & 41st TER SW, then E to 41st ST SW; 23rd PL SW & 41st ST SW, then S to near 2382 41st ST SW, then E along Alleyway Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Property Owner: FLORIDA POWER AND LIGHT 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: 239.434.1240 Contractor: FLORIDA POWER AND LIGHT 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: 239.434.1240 Applicant: Troy Todd 1220 5th Ave N, Florida Power & Light Naples, FL 34102 Telephone Number: 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: As Built Drawings are required prior to final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. You must be signed into the CityView Portal as a registered user to upload the document. Please call 239-252-3726 to schedule inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Page 5585 of 6526 Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5586 of 6526 Date Approved: May 13, 2022 Right-of-Way Permit Number: PRROW2022041730001 SDP/AR/PSP Number: N/A Building Permit Number: N/A Project Name: FPL WR8631058 Modifying existing power poles, making them ready for under ground work Multiple locations: WILLOUGHBY ACR Project Address: Overhead power modification on Euclid Ave from Willowick Dr. to Heritage way Subdivision: Highland Sands Lot:Block:Unit:Tract: Folio No: N/A Section:Township:Range: ******************************************************************************************************************************************************************************** Type of Construction: ROW Commercial Detail: FPL WR8631058 Modifying existing power poles, making them ready for under ground work Multiple locations: Euclid Ave., from Willowick Dr to Heritage Way: WILLOUGHBY ACRES THIS PERMIT IS VALID FOR A PERIOD OF SIX (6) MONTHS FROM THE DATE OF ISSUANCE. Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Applicant: Troy Todd FLORIDA POWER & LIGHT 122 E CHARLOTTE AVE PUNTA GORDA FL, 33950 Telephone Number: (239) 434-1240 Contractor: N/A 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: Before commencement of any excavation, the existing underground utilities in the area affected by the work must be marked by Sunshine One Call, in accordance with State Statute Chapter 556 “Underground Facility Damage Prevention and Safety”, after proper notification to them by either calling 811 in Florida or toll free at 1-800-432-4770. Visit www.callsunshine.com for more information. Before commencing excavation for the work, potholing of all potential conflicts must be performed. Condition: Sunshine 811 Damage Prevention Guide: Chapter 556, F.S., sets a tolerance zone that extends 24 inches from the outer edge of each side of an underground facility. Locate marks show the approximate location of an underground facility. To be sure where that facility is located, you must expose it using a method below: Hand digging at an angle toward the facility Pot holing Soft digging Vacuum excavation methods Other similar procedures Exposing the facility lets you see the facility size and the clearance you need to maintain during excavation. Digging within the tolerance zone requires special precaution and using mechanized equipment requires a spotter. Within existing pavement, soft digging will be required after removal of pavement associated with a permitted open-cut. Page 5587 of 6526 Condition: As Built Drawings are required prior to final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. You must be signed into the CityView Portal as a registered user to upload the document. Please call 239-252-3726 to schedule inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5588 of 6526 Date Approved:March 20, 2020 Right-of-Way Permit Number:PRROW2019083609201 SDP/AR/PSP Number: N/A Building Permit Number: Project Name: FPL WR8778460; OH to UG Conversion; Area of 17th Ave SW; 43rd Ter SW; 43rd St SW; 42nd Ter SW; 42nd S Project Address:WR8778460; Multiple Dir Bore(s); OH to UG Conversion; Area of 17th Ave SW; 43rd Ter SW; 43rd St SW; 42nd Ter SW; 42nd St SW; 41st Ter SW; 18th Pl SW-SEE ATTACHED DRAWINGS. Subdivision:Lot:Block:Unit: Tract: Folio No:Section: 22 Township: 49 Range: 26 ************************************************************************************************************************************************************************************Type of Construction: ROW Commercial Detail:FPL WR8778460; Multiple Dir Bore(s); OH to UG Conversion; Area of 17th Ave SW; 43rd Ter SW; 43rd St SW; 42nd Ter SW; 42nd St SW; 41st Ter SW; 18th Pl SW THIS PERMIT IS VALID FOR A PERIOD OF SIX (6) MONTHS FROM THE DATE OF ISSUANCE. Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Property Owner/Applicant: FLORIDA POWER & LIGHT 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: (941) 637-5553 Contractor: FLORIDA POWER & LIGHT 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: (941) 637-5553 1. Work shall be performed in accordance with approved plan, Conditions of Permit, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a building permit, the right-of-way permit expires upon completion of the building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: The required inspections shall be scheduled through the CityView Portal. Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: As Built Drawings are required to be submitted prior to the request of the final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. Condition: The Road Alert for located in the CityView Portal Documents and Images Tab shall be completed and returned to the email addresses listed at the top of the form a minimum of five business days prior to the lane and sidewalk closure. Condition: Potable water, non-potable irrigation water, and wastewater pipelines shall be separated from telephone, power, cable, and gas sleeves/lines and any other underground utilities by a minimum clear vertical distance of eighteen inches (18”) and horizontal distance of five feet (5’). Please call 239-252-3726 to schedule required 830 inspection FIRST then subsequent inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5589 of 6526 Page 5590 of 6526 Date Approved:August 21, 2020 Right-of-Way Permit Number:PRROW2020062279001 SDP/AR/PSP Number: N/A Building Permit Number: N/A Project Name: FPL WR9091735; Install/Replace 54 pole(s); Storm Secure/Hardening/Maintenance Project Address:FPL WR9091735; Multiple Locations; POB: C/O Green Blvd & 40th Ter SW; Along 40th Ter SW; 18th Ave SW; 41st Ter SW; 17th Ave SW; 45th Ter SW; Install/Replace 54 pole(s); Storm Secure/Hardening/Maintenance; See Attached Drawings Subdivision: N/A Lot:Block:Unit: Tract: Folio No: 75180000201 Section: 15 Township: 49 Range: 26 ************************************************************************************************************************************************************************************Type of Construction: ROW Commercial Detail:FPL WR9091735; Install/Replace 54 pole(s); Storm Secure/Hardening/Maintenance; Multiple Locations; POB: C/O Green Blvd & 40th Ter SW; Along 40th Ter SW; 18th Ave SW; 41st Ter SW; 17th Ave SW; 45th Ter SW; See Attached Drawings THIS PERMIT IS VALID FOR A PERIOD OF SIX (6) MONTHS FROM THE DATE OF ISSUANCE. Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Property Owner/Applicant: FLORIDA POWER & LIGHT C/O NANCY SHEARER 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: (941) 637-5553 Contractor: 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: Please be advised there is a future stormwater improvement project planned for Golden Gate City. Condition: Please be advised, there is a future water main and sanitary sewer expansion project planned for Golden Gate City. Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: Whenever necessary for the construction, repair, maintenance, improvement, alteration. or relocation of said right-of-way or easement as determined by Collier County, any or all poles, wires, culvert pipes, cables, sod, landscaping, driveways, sprinklers, or other facilities and appurtenances authorized shall be removed from said right-of-way or easement, or reset or relocated thereon as required and so notified by the County, and at the expense of the Permittee, his successor, or assignees. Please call 239-252-3726 to schedule required 830 inspection FIRST then subsequent inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5591 of 6526 Date Approved: June 15, 2022 Right-of-Way Permit Number: PRROW2022041751001 SDP/AR/PSP Number: N/A Building Permit Number: N/A Project Name: FPL WR8631062 Place Underground Power and remove overhead power Multiple locations:crossing Euclid Ave on Willowick Dr Project Address: Crossing Euclid Ave going down Erie Dr. from Euclid Ave down Madison DR. and Saybrook Ct. Subdivision: Willoughby Acres Lot:Block:Unit:Tract: Folio No: N/A Section:Township:Range: ******************************************************************************************************************************************************************************** Type of Construction: ROW Commercial Detail: FPL WR8631062 Place Underground Power and remove overhead power Multiple locations: crossing Euclid Ave on Willowick Dr to Turnbury Way and Lakeland Ave WILLOUGHBY ACRES Please refer to Collier County Portal for issuance and expiration dates. ******************************************************************************************************************************** Applicant: Troy Todd FOR FLORIDA POWER & LIGHT 122 E CHARLOTTE AVE PUNTA GORDA, FL 33950 Telephone Number: (239) 434-1240 Contractor: N/A 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Transportation Services Division approval does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: All other applicable state or federal permits must be obtained before commencement of the development. Condition: The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: Before commencement of any excavation, the existing underground utilities in the area affected by the work must be marked by Sunshine One Call, in accordance with State Statute Chapter 556 “Underground Facility Damage Prevention and Safety”, after proper notification to them by either calling 811 in Florida or toll free at 1-800-432-4770. Visit www.callsunshine.com for more information. Before commencing excavation for the work, potholing of all potential conflicts must be performed. Condition: Sunshine 811 Damage Prevention Guide: Chapter 556, F.S., sets a tolerance zone that extends 24 inches from the outer edge of each side of an underground facility. Locate marks show the approximate location of an underground facility. To be sure where that facility is located, you must expose it using a method below: Hand digging at an angle toward the facility Pot holing Soft digging Vacuum excavation methods Other similar procedures Exposing the facility lets you see the facility size and the clearance you need to maintain during excavation. Digging within the tolerance zone requires special precaution and using mechanized equipment requires a spotter. Within existing pavement, soft digging will be required after removal of pavement associated with a permitted open-cut. Condition: As Built Drawings are required prior to final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. You must be signed into the CityView Portal as a registered user to upload the document. Page 5592 of 6526 Condition: Please plan accordingly when scheduling inspections and schedule well in advance of when needed or permit expiration dates. Please call 239-252-3726 to schedule inspections listed below. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS Page 5593 of 6526