Loading...
HEX Agenda 08/28/2025COLLIER COUNTY Hearing Examiner AGENDA Conference Room 609/610 Growth Management Community Development 2800 North Horseshoe Drive Naples, FL 34104 August 28, 2025 1:00 PM Andrew W. J. Dickman, Esq., AICP Hearing Examiner Note: Individual speakers will be limited to 5 minutes unless otherwise waived by the Hearing Examiner. Persons Wishing to have written or graphic materials included in the hearing report packets must have that material submitted to County staff at Ailyn.Padron@CollierCountyFL.gov 10 days prior to the Hearing. All materials used during presentation at the hearing will become a permanent part of the record. Any person who decides to appeal a decision of the Hearing Examiner will need a record of the proceedings pertaining thereto, and therefore may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. Decisions of the Hearing Examiner are final unless appealed to the Board of County Commissioners. Hearing Procedures will provide for presentation by the Applicant, presentation by staff, public comment and applicant rebuttal. The Hearing Examiner will render a decision within 30 days. Persons wishing to receive a copy of the decision by mail may supply County staff with their name, address, and a stamped, self-addressed envelope for that purpose. Persons wishing to receive an electronic copy of the decision may supply their email address. 1. Pledge of Allegiance 2. Review of Agenda 3. Advertised Public Hearing 3.A. Petition No. BD-PL20240013776 – 10 Pelican St. E- Request for a 12-foot boat dock extension from the maximum permitted protrusion of 20 feet allowed by Section 5.03.06.E.1 of the Collier County Land Development Code (LDC) for waterways greater than 100 feet in width, to allow a boat docking facility protruding a total of 32 feet into a waterway that is 840± feet wide, pursuant to LDC Section 5.03.06.H. The subject property is located at 10 Pelican Street East and is further described as Lot 17 and the east 10 feet of Lot 16, Isles of Capri No. 1, in Section 5, Township 52 South, Range 26 East, Collier County, Florida. [Coordinator: John Kelly, Planner III] Commission District 1 (2025-2569) 4. New Business 5. Old Business Page 1 of 99 6. Public Comments 7. Adjourn Page 2 of 99 8/28/2025 Item # 3.A ID# 2025-2569 Petition No. BD-PL20240013776 – 10 Pelican St. E- Request for a 12-foot boat dock extension from the maximum permitted protrusion of 20 feet allowed by Section 5.03.06.E.1 of the Collier County Land Development Code (LDC) for waterways greater than 100 feet in width, to allow a boat docking facility protruding a total of 32 feet into a waterway that is 840± feet wide, pursuant to LDC Section 5.03.06.H. The subject property is located at 10 Pelican Street East and is further described as Lot 17 and the east 10 feet of Lot 16, Isles of Capri No. 1, in Section 5, Township 52 South, Range 26 East, Collier County, Florida. [Coordinator: John Kelly, Planner III] Commission District 1 ATTACHMENTS: 1. Staff Report 08052025 2. Attachment A - Proposed Site and Dock Plans 3. Attachment B - Map of Specific Purpose Survey 4. Attachment C - Partial Permit File, PRFH20240728089 5. Attachment D - Applicant’s Backup; Application and Supporting Documents 6. Attachment E - Public Hearing Posting 08122025 Page 3 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 1 of 8 STAFF REPORT TO: COLLIER COUNTY HEARING EXAMINER FROM: ZONING DIVISION – ZONING SERVICES SECTION GROWTH MANAGEMENT COMMUNITY DEVELOPMENT DEPARTMENT HEARING DATE: AUGUST 28, 2025 SUBJECT: BD-PL20240013776, 10 PELICAN STREET EAST - BOAT DOCK PROPERTY OWNER/APPLICANT: AGENT: Warbler, LLC / Jean M. Unruh Gift Trust Jeff Rogers Victor O. Unruh, Trustee Turrell, Hall & Associates, Inc. 1908 Unruh Ct. 3584 Exchange Ave. New Albany, IN 47150 Naples, FL 34104 REQUESTED ACTION: The petitioner requests a 12-foot boat dock extension from the maximum permitted protrusion of 20 feet allowed by Section 5.03.06.E.1 of the Collier County Land Development Code (LDC) for waterways 100 feet or greater in width, to allow a new boat dock facility protruding a total of 32 feet into a waterway that is 840± feet wide, pursuant to LDC Section 5.03.06.H. GEOGRAPHIC LOCATION: The subject property is located at 10 Pelican Street East, also known as Lot 17 and the east 10 feet of Lot 16, Isles of Capri No. 1, in Section 5, Township 52 South, Range 26 East, Collier County, Florida. (See location map on the following page) PURPOSE/DESCRIPTION OF PROJECT: The subject property, comprising 0.22 acres, is located within a Residential-Single Family – 4 (RSF-4) zoning district. A single-family residence is being constructed per Building Permit No. PRFH20240728089. The property has approximately 85 feet of seawalled shoreline with sporadic riprap, adjacent to the Big Marco River located within the Rookery Bay Aquatic Preserve. The petitioner desires to construct a new residential dock facility comprising a finger pier with two slips, each with a boatlift, to accommodate two 24-foot vessels. The requested 32- foot protrusion is measured from the property line, which is landward of the mean high-water line, and is necessary due to water depths; 15-foot side setbacks are also required. Page 4 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 2 of 8 SURROUNDING LAND USE & ZONING: North: Pelican Street East (Right-of-Way), then a single-family dwelling located within a Residential Single Family-4 (RSF-4) zoning district East: A Single-family dwelling located within a Residential Single Family-4 (RSF-4) zoning district South: Big Marco River is located within an agricultural zoning district and within a Special Treatment Overlay (A-ST) West: A Single-family dwelling located within a Residential Single Family-4 (RSF-4) zoning district Page 5 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 3 of 8 Aerial – Collier County GIS Page 6 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 4 of 8 Aerial – Collier County GIS ENVIRONMENTAL EVALUATION: Environmental Planning Staff has reviewed this petition and has no objection to the granting of this request. The property is located adjacent to an ST overlay zone (Marco River), which will require an ST-permit for the proposed docking facilities before issuance of any building permits. The proposed docking facilities will be constructed waterward of the existing seawalled shoreline. The shoreline does not contain native vegetation. A survey provided by the applicant found no submerged resources in the area 200 feet beyond the proposed docking facility. (Submerged Resource Survey exhibit sheet 9 of 10). This project does not require an Environmental Advisory Council Board (EAC) review, because this project did not meet the EAC scope of land development project reviews as identified in Chapter 2, Article VIII, Division 23, Section 2-1193 of the Collier County Code of Laws and Ordinances. Page 7 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 5 of 8 STAFF ANALYSIS: In accordance with LDC Section 5.03.06.H., the Collier County Hearing Examiner shall approve, approve with conditions, or deny a dock facility extension request based on certain criteria. In order for the Hearing Examiner to approve this request, at least four of the five primary criteria and four of the six secondary criteria must be met: Primary Criteria: 1. Whether the number of dock facilities and/or boat slips proposed is appropriate in relation to the waterfront length, location, upland land use, and zoning of the subject property. Consideration should be made of property on unbridged barrier islands, where vessels are the primary means of transportation to and from the property. (The number should be appropriate; typical single-family use should be no more than two slips; typical multi-family use should be one slip per dwelling unit; in the case of unbridged barrier island docks, additional slips may be appropriate.) Criterion met. The subject property is located within an RSF-4 zoning district and will support a single-family dwelling for which the LDC allows two boat slips. The proposed dock has been designed to accommodate two 24-foot vessels, one to be on a 16-foot by 16-foot lift and the other on a 16-foot by 20-foot lift. 2. Whether the water depth at the proposed site is so shallow that a vessel of the general length, type, and draft as that described in the petitioner’s application is unable to launch or moor at mean low tide (MLT). (The petitioner’s application and survey should establish that the water depth is too shallow to allow launching and mooring of the vessel(s) described without an extension.) Criterion met. The applicant’s agent states: “The proposed boat dock extension is necessary to extend out to sufficient water depths, which is limited by the State’s aquatic preserve rules on the allowed overall protrusion being limited to terminating at the -4‘ MLW contour line. Additionally, the aquatic preserve will not allow for any dredging activities, which would limit the overall protrusion to reach greater water depths or create sufficient depths to reduce the overall proposed dock protrusion.” Zoning staff concurs. 3. Whether the proposed dock facility may have an adverse impact on navigation within an adjacent marked or charted navigable channel. (The facility should not intrude into any marked or charted navigable channel, thus impeding vessel traffic in the channel.) Criterion met. The applicant’s agent states: “The proposed docking facility design is consistent with numerous other existing docking facilities along the subject and adjacent waterways. As proposed, the dock and boatlifts will not impact navigation within the subject waterway, nor will they alter the existing ingress/egress to both adjacent neighboring docks and the associated slips. There is a marked channel within the Marco River which provides safe navigation between the markers, which are just waterward of Page 8 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 6 of 8 the existing docking facilities. Based on this, as proposed, there are no new impacts to any navigation as a result of the proposed project.” Zoning staff concurs. 4. Whether the proposed dock facility protrudes no more than 25 percent of the width of the waterway, and whether a minimum of 50 percent of the waterway width between dock facilities on either side is maintained for navigability. (The facility should maintain the required percentages.) Criterion met. The approximate waterway width is 840 feet. The requested total dock protrusion is 32 feet, which is under 4 percent of the width of the waterway. The clear distance between the subject dock facility and that on the opposite shore is 703 feet; therefore, 83.81 percent of the waterway is open for navigation. 5. Whether the proposed location and design of the dock facility is such that the facility would not interfere with the use of neighboring docks. (The facility should not interfere with the use of legally permitted neighboring docks.) Criterion met. The applicant’s agent states: “The proposed docking facility design and overall location will not interfere with the existing adjacent dock facilities. As proposed, the dock will be within the allowed buildable area by providing the required setbacks, and therefore, the views into the subject waterway by the adjacent property owners will not be impacted, nor will their access to their docks. Zoning staff concurs. Secondary Criteria: 1. Whether there are special conditions not involving water depth, related to the subject property or waterway, which justify the proposed dimensions and location of the proposed dock facility. (There must be at least one special condition related to the property; these may include type of shoreline reinforcement, shoreline configuration, mangrove growth, or seagrass beds.) Criterion met. The applicant’s agent states: “The special conditions taking into consideration with the proposed dock layout are the two adjacent existing grandfathered docking facilities [on either side of the subject property]. Both these docks extend out past the 20-foot mark and the -4’ MLW contour line, limiting access to an angled or shore parallel dock design. Additionally, both adjacent docks are within the required 15- foot setback line, further limiting any dock/slip design that would allow the proposed dock to reduce the overall proposed protrusion and still provide safe access.” Given the agent’s explanation of the State’s aquatic preserve rules, Zoning staff concurs. 2. Whether the proposed dock facility would allow reasonable, safe access to the vessel for loading/unloading and routine maintenance, without the use of excessive deck area not directly related to these functions. (The facility should not use excessive deck area.) Criterion met. The applicant’s agent states: “The proposed docking facility has been fully minimized to the fullest extent possible and still provides deck area for routine. Page 9 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 7 of 8 maintenance, safe access, as well as recreational activities like fishing, plus storage for these activities, the dock provides. The total over-water square footage is 899 square feet.” Zoning staff concurs. 3. For single-family dock facilities, whether the length of the vessel, or vessels in combination, described by the petitioner, exceeds 50 percent of the subject property’s linear waterfront footage. (The applicable maximum percentage should be maintained.) Criterion not met. The proposed dock facility has been designed for mooring two 24- foot vessels. The total shoreline at this location is 85 feet. The total length of vessels is 48 feet, which exceeds the 50 percent threshold. 4. Whether the proposed facility would have a major impact on the waterfront view of neighboring property owners. (The facility should not have a major impact on the view of a neighboring property owner.) Criterion met. The applicant’s agent states: “The existing on-site conditions consist of no docking facility, but both adjacent neighboring property owners have docks along the subject property shoreline. As proposed, the dock has been designed within the designated setbacks and is consistent with the other existing boat docks on the subject waterway. Based on this, it’s our opinion that there are no new impacts to either the adjacent property owner or their current view of the subject waterway. Additionally, this is a boating community; therefore, docks are all part of the overall atmosphere in this community.” Zoning staff concurs. 5. Whether seagrass beds will be impacted by the proposed dock facility. (If seagrass beds are present, compliance with subsection 5.03.06(I) of the LDC must be demonstrated.) Criterion met. There are no seagrass beds present on the property nor the neighboring properties within 200-feet of the existing dock structure. 6. Whether the proposed dock facility is subject to the manatee protection requirements of subsection 5.03.06(E)(11) of this Code. (If applicable, compliance with section 5.03.06(E)(11) must be demonstrated.) Criterion is not applicable. Criterion not applicable. The provisions of the Collier County Manatee Protection Plan do not apply to single-family dock facilities except for those within the seawalled basin of Port of the Islands; the subject property is not located within Port of the Islands. Staff analysis finds this request complies with five of the five primary criteria. With respect to the six secondary criteria, one of the criteria is found to be not applicable; the request meets four of the remaining five secondary criteria. CONCURRENT LAND USE APPLICATIONS: Page 10 of 99 BD-PL20240013776 – 10 Pelican St E August 5, 2025 Page 8 of 8 There are no concurrent land use applications under review at the present time. APPEAL OF BOAT DOCK EXTENSION: As to any boat dock extension petition upon which the Hearing Examiner takes action, an aggrieved party may appeal such final action. Such appeal shall be filed per Section 2-88 of the Collier County Code of Ordinances within 30 days of the Decision by the Hearing Examiner. An aggrieved non-party may appeal a decision of the Hearing Examiner to the Circuit Court of Collier County within 30 days of the decision. In the event that the petition has been approved by the Hearing Examiner, the applicant shall be advised that he/she proceeds with construction at his/her own risk during this 30-day period. Any construction work completed ahead of the approval authorization shall be at their own risk. STAFF RECOMMENDATION: Based on the above findings, the staff recommends that the Hearing Examiner APPROVE Petition BD-PL20240013776, allow for the permitting and construction of the proposed dock facility as depicted within the plans contained in Attachment A, subject to the following Condition of Approval: • A Certificate of Completion for the requested accessory dock facility may not be issued until a Certificate of Occupancy is issued for the principal structure. Attachments: A) Proposed Site and Dock Plans B) Map of Specific Purpose Survey C) Partial Permit File, PRFH20240728089 D) Applicant’s Backup; Application and Supporting Documents E) Public Hearing Sign Posting Page 11 of 99 STATE OF FLORIDACOUNTY AERIAL VICINITY MAPSTATE OF FLORIDACOUNTY AERIAL VICINITY MAPNOTES:<> THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SUBJECTPROPERTYSUBJECTPROPERTY<> LATITUDE:N 25.976580<> LONGITUDE:W -81.729993SITE ADDRESS:<> 10 PELICAN ST E NAPLES, FL 34113Turrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg LOCATION MAP 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST ELOCATION MAP52RMJ---06-10-25----SHEETS 04-06,10----RMJ----01 OF 10COLLIER COUNTYCOLLIER COUNTYGULF OF MEXICOGULF OF MEXICO8588288641MARCOISLANDEVERGLADESCITY9329846NAPLES90908399483783784129292983983992887846951862I-758486431856850846890896NESWKEY WESTTAMPAFT.MYERSMIAMINAPLESSUBJECTPROPERTYPage 12 of 99 NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 1952 AERIAL 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST E1952 AERIAL52-------------------02 OF 10·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'PROPERTYBOUNDARYPage 13 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW0153060SCALE IN FEETSITE ADDRESS:,10 PELICAN ST ENAPLESFL34113Turrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg EXISTING CONDITIONS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EEXISTING CONDITIONS52-------------------03 OF 10·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'EXISTINGSEAWALLRIPARIAN LINERIPARIAN LINEPROPERTY BOUNDARY85'EXISTING SPORADIC RIPRAP-4' MLWCONTOURLINEEXISTINGADJACENTDOCKEXISTINGADJACENTDOCK20.1'EXISTINGADJACENTLIFT PILES7.5'8.7'20.7'11.7'12'85'115' 115'Page 14 of 99 p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 6/10/2025NESW0102040SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg DOCK PLAN - DIMENSIONS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EDOCK PLAN - DIMENSIONS52----06-10-25----JR----REVISED LIFT----04 OF 10PILE COUNTTYPESIZEQUANTITYWOOD PILE10"6WOOD PILE12"8PILES IN WATER IMPACTS = 10 SF (QTY: 14)EXISTINGSEAWALLRIPARIANLINERIPARIAN LINEPROPERTY BOUNDARY16' x 16'BOAT LIFT30'5'TERMINALPLATFORM(149 SF)-4' MLW CONTOUR LINEEXISTINGADJACENTDOCKEXISTING SPORADIC RIPRAP16' X 20'BOAT LIFT16'20'12'2' x 16' CATWALK16'16'31' 32'4' 24'24'22'22'25'·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:·PROPOSED OVERWATER STRUCTURE (APPX SF):·TOTAL OVERWATER STRUCTURE (APPX SF):·TOTAL PROTRUSION FROM PROPERTY LINE:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'21721732'Page 15 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 6/10/2025NESW0102040SCALE IN FEETTERMINAL PLATFORMTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg DOCK PLAN - DEPTHS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EDOCK PLAN - DEPTHS52----06-10-25----JR----REVISED LIFT----05 OF 10EXISTINGSEAWALLRIPARIAN LINERIPARIAN LINEPROPERTY BOUNDARYBOAT LIFT-4' MLW CONTOUR LINEEXISTING SPORADIC RIPRAPAA06BOAT LIFT·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:·PROPOSED OVERWATER STRUCTURE (APPX SF):·TOTAL OVERWATER STRUCTURE (APPX SF):·TOTAL PROTRUSION FROM PROPERTY LINE:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'21721732'Page 16 of 99 -4.0'- 2 . 0 '0248SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg CROSS SECTION AA 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST ECROSS SECTION AA52----06-10-25----JR----ADDED VESSEL----06 OF 10BIGMARCORIVERFIXEDDOCK16' BOAT LIFTMHW = +0.43' NAVDMLW =-1.60' NAVDALL PILES TO BEWRAPPED FROM 12"ABOVE MHWL TO 6"BELOW SUBSTRATE36"EXISTINGSEAWALL32' PROTRUSION FROMPROPERTY LINEFIXEDACCESSDOCKCATWALK4'PROPERTYLINEPage 17 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg ADJACENT DOCK 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EADJACENT DOCK52-------------------07 OF 10PROPERTYLINENOTE:THE DIMENSIONS SHOWN ARE APPROXIMATEAND ARE TAKEN FROM THE AERIAL IMAGE.32' 70' 63' 56' 66' 54' 82' 71' 71' 147' 47' 50' 34' 51' 33' 29' 43'20'20'Page 18 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW03060120SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg ST OVERLAY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EST OVERLAY52-------------------08 OF 10STOVERLAYPROPERTYLINEPage 19 of 99 NESW0204080SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg SUBMERGED RESOURCE SURVEY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST ESUBMERGED RESOURCE SURVEY52-------------------09 OF 10TYPICAL DIVE TRANSECTNO SEAGRASSES WEREOBSERVED GROWINGWITHIN 200 FT OF THEPROPOSED PROJECTTRANSECTPROPERTYLINE200'200'10' O.C.Page 20 of 99 NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg WIDTH OF WATERWAY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EWIDTH OF WATERWAY52----06-10-25----JR----REVISED DIMENSION----10 OF 10NOTE:THE DIMENSIONS SHOWN ARE APPROXIMATEAND ARE TAKEN FROM THE AERIAL IMAGE.PROPERTYLINE841' 703' 840'Page 21 of 99 Page 22 of 99 PRFH2024072808901 COLLIER COUNTY BOARD OF COUNTY COMMISSIONERS PERMIT PERMIT #: PRFH2024072808901 PERMIT TYPE: Building DATE ISSUED: October 06, 2024 BUILDING CODE IN EFFECT: FBC 8th Edition 2023 JOB ADDRESS: 10 Pelican ST E, Naples FOLIO #: JOB DESCRIPTION: Construction of a new single family home. Roof-Tile. Ref PRROW20240728090 10 PELICAN ST E, Naples, lot 16 OWNER INFORMATION: WARBLER LLC 1908 UNRUH CT NEW ALBANY, IN 47150 AREA OF WORK (SQFT): 6142 SETBACKS: FRONT: 25' REAR: 25' P / 10? A LEFT: 7.5' RIGHT: 7.5' FLOOD ZONE: VE SEWER: Septic WATER: Existing CONTRACTOR INFORMATION:CERTIFICATE #: LUXURY HOMES OF SW FLORIDA, INC. 870 BALD EAGLE DR STE 1B MARCO ISLAND, FL 34145 (239) 293-3627 LCC20240000682 SUB CONTRACTOR INFORMATION: EC AIR PRO, INC 1110 NE PINE ISLAND RD 11 CAPE CORAL, FL 33909 (239) 574-4700 AR BEST PLUMBING LLC 2741 12TH AVE NE NAPLES, FL 34120 (239) 227-3776 A-PLUS ROOFING AND WATERPROOFING LLC 2336 CLEVELAND AVE SUITE D FORT MYERS, FL 33901 (239) 220-2020 PL ELECTRICAL CONTRACTOR LLC 4690 25TH AVE SW NAPLES, FL 34116 (239) 331-9740 Page 23 of 99 PRFH2024072808901 INSPECTION JOB CARD To schedule inspections call 239-252-3726 or visit https://cvportal.colliercountyfl.gov/cityviewweb SETBACKS: FRONT:25'REAR:25' P / 10? A LEFT:7.5'RIGHT:7.5'SPECIAL:FLOOD ZONE: FZVE INSPECTION OUTCOME COMMENTS 101 - Pile Caps 102 - Grade Beam To include the utility footing rebar (UFR) 103 - Floating Slab 104 - Tie Beam 106 - Columns 107 - Truss/Sheathing/Bucks 108 - Framing All rough trade inspections must be passed prior to scheduling. 109 - Insulation 111 - Dry-in/Flashing 115 - Building Final 119 - Fill Cells 121 - Elevated Structural Deck 124 - Steel In Stairs 134 - Roofing Final 136 - Impact Glass 151 - Shearwall/Nailing 152 - Shearwall/Water Barrier 153 - Shearwall/Stucco Lath 154 - Soffit Coverings In progress Please do NOT complete Soffit installation prior to inspection. 200 - Plumbing Underground 201 - Plumbing Rough-in When applicable a shower pan liner test is required. 202 - Plumbing Stack 203 - Sewer Tap Page 24 of 99 PRFH2024072808901 204 - Plumbing Final 300 - A/C Rough 301 - A/C Final 501 - Electrical Rough 502 - Electrical Final 505 - Temporary Power Residential 508 - TV/Telephone Rough 509 - TV/Telephone Final 801 - Site Drainage Type II Stormwater Plan. Signed & Sealed by PE. 802 - Landscaping 805 - Septic in Progress 810 - Exotic Vegetation Removal 813 - Final Septic 814 - Erosion/Silt The 814 - Erosion/Silt must be passed before any other inspections are scheduled. OPEN CONDITIONS Condition Type:Condition Description: Informational NOTICE OF CLEARING RESTRICTIONS: The issuance of a building permit for a single-family dwelling allows up to one (1) acre of native vegetation to be cleared. Clearing more than one (1) acre may be allowed for accessory structures and requires a separate Vegetation Removal Permit. Properties located in the following zoning district overlays may not be allowed to clear one (1) acre: Rural Fringe Mixed Use District (RFMU), Big Cypress Area of Concern (ACSC), and Special Treatment Overlay (ST). There may be additional restrictions related to clearing native vegetation and impacts to wetlands or protected species found on the property. State and Federal agency permits may be required. Contact the Growth Management Department?s Environmental Services at (239) 252-2400 for additional information. CO Hold CO Hold Address or Folio (will, may) change, verify location is correct with addressing prior to Final Typing of Permit Informational - All Auxiliary Permits must obtain Certificate of Completions (C.C.) - Satisfy all Required Conditions, including but not limited to approval of uploaded documents. - Payment of All Outstanding Fees Inspection Hold Notice of Commencement: Upload to the condition on the portal. Informational Use the form located at https://www.colliercountyfl.gov/home/showdocument?id=105797&t=638403984984558370 to request Permit extensions, cancellations, and changes/withdrawals of Contractors, Subcontractors and Qualifiers. Instructions are provided with the form. Right-of-Way (ROW) and Well permits may only use this process for cancellations. Change/withdrawal of contractor does not apply to self-issued permits. Contact Building Permit Resolution Services at 239-252-2493 for assistance completing the form. Submit the form by clicking the Page 25 of 99 PRFH2024072808901 Browse button below. Informational BDT ? Blower Door Test will be uploadable after the PASS of the 109 insulation inspection. Informational Energy Calculation Summary Sheet will be uploadable after the PASS of the 109 insulation inspection. Informational FEMA - All equipment must be above flood plus one foot. Any materials used below flood level must comply with FEMA regulations Informational A Survey is required and must verify that improvement(s) meet setbacks, easements, and elevation requirements per Chapter 62, Collier County Code of Laws and Ordinances. Throughout the duration of the permit, please review the survey conditions for when to upload the survey. CO Hold Soil Compaction Test. Upload to the condition on the portal. CO Hold Any required County impact fees will be due prior to issuance of a temporary or final Certificate of Occupancy CO Hold A separate permit is required for: - Propane Tank - Pool - Planter Wall and Pool Stemwall CO Hold This building permit has a Type II stormwater management plan, signed and sealed by a registered Florida Professional Engineer as was reviewed by Development Review. Prior to scheduling the 801 inspection, please upload the signed and sealed stormwater certification letter to the condition in the portal. If you have further questions, please contact Engineering Services at 239-252-2417. CO Hold At the time of permit application, the permitted structure is in the special flood hazard area. An Under Construction Elevation Certificate is required within 10 days of passing a 103 or 133 inspection of slab or other foundation system. Prior to obtaining County approval of the Under Construction Elevation Certificate, the permit holder?s construction activities are at his/her own risk. Under Construction Elevation Certificates must verify the slab meets minimum elevations per the Florida Building Code and Chapter 62, Collier County Code of Laws and Ordinances (e.g., BFE +1 or 18? above the crown of the road, whichever is higher, and the elevation established by the SFWMD permit). CO Hold BFE= COASTAL AE-10.00 ft NAVD, Per Plans: Crown of Road (CoR)= Not Provided, Proposed Ground Living Level FFE= 11.00 ft NAVD, Next Living Level FFE= 25.50 ft NAVD (Pg. A-2), Garage's Lowest FFE= 7.00 ft NAVD with 3 each CSBA816 Flood Vents (305 sf ea of capacity) in oppossite walls to vent 772 SF of garage; All Equipment Pads to be BFE+1 foot minimum, Break away walls provided but missing structural detail. Elevator below Flood complying with FEMA Techincal Bulletin 4 & ASCE 24 provided (Pg.A-4), Materials Below Flood Note provided (Pg.A-4). FrancoJohann 09/27/2024 5:52 PM CO Hold Sub Contractor (Septic) Upload to the condition on portal. CO Hold All Ancillary permits must be FINAL and ALL conditions on the permit must be resolved prior to Curbside Solid Waste Collection fee being added to the permit. NOTE: If you are unable to schedule your inspection, please contact the inspection desk at 252-2400. NOISE ORDINANCE: Collier County Codes of Laws and Ordinances 54-92(f) Construction Sound. NOISE LIMITATIONS are in effect at all times. Work permitted, RESIDENTIAL Areas – 6:30 AM to 7:00 PM Monday thru Saturday; NON-RESIDENTIAL Areas (more than 500 feet from Residential Area) 6:00AM to 8:00PM Monday thru Saturday. No Work on Sundays or Holidays. RADIOS, LOUDSPEAKERS, ETC. – Must not disturb peace, quiet and comfort of neighboring inhabitants. FREE CABLE LOCATIONS – Call 48 Hours prior to digging/FPL 434-1222/UTS 1-800-542-0088/PalmerCATV 783-0638 and all other applicable utilities. Per currently adopted building code ordinance, as it may be amended, all work must comply with all applicable laws, codes, ordinances, and any additional stipulations or conditions of this permit. This permit expires if work authorized by the permit is not commenced within six (6) months from the date of issuance of the permit. Additional fees for failing to obtain permits prior to the commencement of construction may be imposed. Permittee(s) further understands that any contractor that may be employed must Page 26 of 99 PRFH2024072808901 be a licensed contractor and that the structure must not be used or occupied until a Certificate of Occupancy is issued. NOTICE: PRIOR TO THE REMOVAL OF ASBESTOS PRODUCTS OR THE DEMOLITION OF A STRUCTURE, FEDERAL AND STATE LAWS REQUIRE THE PERMITTEE (EITHER THE OWNER OR CONTRACTOR) TO SUBMIT A NOTICE OF THE INTENDED WORK TO THE STATE DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP). FOR MORE INFORMATION, CONTACT DEP AT (239) 344-5600. NOTICE: In addition to the conditions of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Page 27 of 99 Page 28 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 1 of 7 Planning and Zoning Division • 2800 North Horseshoe Drive • Naples, FL 34104 • 239-252-2400 www.colliercountyfl.gov Need Help? GMCD Public Portal Online Payment Guide E-Permitting Guides THIS PETITION IS FOR (check one or both, if applicable): BOATHOUSE DOCK EXTENSION Name of Property Owner(s): Name of Applicant if different than owner: Address: City: State: ZIP: Telephone: Cell: E-Mail Address: Name of Agent: Firm: Address: City: State: ZIP: Telephone: Cell: E-Mail Address: Section/Township/Range: / / Property ID Number: Subdivision: Unit: Block: Lot: Address/ General Location of Subject Property: Current Zoning and Land Use of Subject Property: APPLICANT INFORMATION PROPERTY LOCATION BOATHOUSE ESTABLISHMENT PETITION OR BOAT DOCK FACILITY EXTENSION Land Development Code Section 5.03.06 Chapter 3 B.1 or B.2 of the Administrative Code BE AWARE THAT COLLIER COUNTY HAS LOBBYIST REGULATIONS. GUIDE YOURSELF ACCORDINGLY AND ENSURE THAT YOU ARE IN COMPLIANCE WITH THESE REGULATIONS. Page 29 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 2 of 7 Zoning Land Use N S E W Narrative description of project (indicate extent of work, new dock, replacement, addition to existing facility, any other pertinent information): 1. Water Width: ft. Measurement from: plat survey visual estimate other(specify): 2. Total Property Water Frontage: ft. 3. Setbacks: Provided: ft. Required: ft. 4. Total Protrusion of Proposed Facility into Water: ft. 5. Number and Lengths of Vessels to Use Facility: 1. ft. 2. ft. 3. ft. 4. ft. 6. If applicable, the distance between dock facilities per the Land Development Code section 5.03.06 H.1.d. ft. 7. List any additional dock facilities in close proximity to the subject property and indicate the total protrusion into the waterway of each: ADJACENT ZONING AND LAND USE DESCRIPTION OF PROJECT SITE INFORMATION Page 30 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 3 of 7 1. Signs are required to be posted for all petitions. On properties that are one (1) acre or larger in size, the applicant shall be responsible for erecting the required sign. What is the size of the petitioned property? Acres 2. Official Interpretations or Zoning Verifications: To your knowledge, has there been an official interpretation or zoning verification rendered on this property within the last year? Yes No (If yes, please provide a copy.) The following criteria, pursuant to LDC section 5.03.06, shall be used as a guide by staff in determining its recommendation to the Office of the Hearing Examiner. The Hearing Examiner will utilize the following criteria as a guide in the decision to approve or deny a particular Dock Extension request. In order for the Hearing Examiner to approve the request, it must be determined that at least 4 of the 5 primary criteria, and at least 4 of the 6 secondary criteria, must be met. On separate sheets, please provide a narrative response to the listed criteria and/or questions. 1. Whether or not the number of dock facilities and/or boat slips proposed is appropriate in relation to the waterfront length, location, upland land use, and zoning of the subject property; consideration should be made of property on unbridged barrier islands, where vessels are the primary means of transportation to and from the property. (The number should be appropriate; typical, single-family use should be no more than two slips; typical multi- family use should be one slip per dwelling unit; in the case of unbridged barrier island docks, additional slips may be appropriate.) 2. Whether or not the water depth at the proposed site is so shallow that a vessel of the general length, type, and draft as that described in the petitioner’s application is unable to launch or moor at mean low tide (MLT). (The petitioner’s application and survey should show that the water depth is too shallow to allow launch and mooring of the vessel(s) described without an extension.) 3. Whether or not the proposed dock facility may have an adverse impact on navigation within an adjacent marked or charted navigable channel. (The facility should not intrude into any marked or charted navigable channel thus impeding vessel traffic in the channel.) 4. Whether or not the proposed dock facility protrudes no more than 25% of the width of the waterway, and whether or not a minimum of 50% of the waterway width between dock facilities on either side of the waterway is maintained for navigability. (The facility should maintain the required percentages.) 5. Whether or not the proposed location and design of the dock facility is such that the facility would not interfere with the use of neighboring docks. (The facility should not interfere with the use of legally permitted neighboring docks.) DOCK EXTENSION PRIMARY CRITERIA Page 31 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 4 of 7 1. Whether or not there are special conditions, not involving water depth, related to the subject property or waterway, which justify the proposed dimensions and location of the proposed dock facility. (There must be at least one special condition related to the property; these may include type of shoreline reinforcement, shoreline configuration, mangrove growth, or seagrass beds.) 2. Whether the proposed dock facility would allow reasonable, safe, access to the vessel for loading/ unloading and routine maintenance, without the use of excessive deck area not directly related to these functions. (The facility should not use excessive deck area.) 3. For single-family dock facilities, whether or not the length of the vessel, or vessels in combination, described by the petitioner exceeds 50 percent of the subject property’s linear waterfront footage.(The applicable maximum percentage should be maintained.) 4. Whether or not the proposed facility would have a major impact on the waterfront view of neighboring waterfront property owners. (The facility should not have a major impact on the view of either property owner.) 5. Whether or not seagrass beds are located within 200 feet of the proposed dock facility. (If seagrass beds are present, compliance with LDC subsection 5.03.06 J must be demonstrated.) 6. Whether or not the proposed dock facility is subject to the manatee protection requirements of LDC subsection 5.03.06 E.11. (If applicable, compliance with subsection 5.03.06.E.11 must be demonstrated.) The following criteria, pursuant to LDC section 5.03.06 F, shall be used as a guide by staff in determining its recommendation to the decision maker. The decision maker will utilize the following criteria as a guide in the decision to approve or deny a particular Boathouse request. In order for the request to be approved, all of the criteria must be met. On separate sheets, please provide a narrative response to the listed criteria and/or questions. 1. Minimum side setback requirement: Fifteen feet. 2. Maximum protrusion into waterway: Twenty-five percent of canal width or 20 feet, whichever is less. The roof alone may overhang no more than 3 feet into the waterway beyond the maximum protrusion and/or side setbacks. 3. Maximum height; Fifteen feet as measured from the top of the seawall or bank, whichever is more restrictive, to the peak or highest elevation of the roof. 4. Maximum number of boathouses and covered structures per site: One. 5. All boathouses and covered structures shall be completely open on all 4 sides. 6. Roofing material and roof color shall be the same as materials and colors used on principal structure or may be a palm frond “chickee” style. A single-family dwelling unit must be constructed on the subject lot prior to, or simultaneously with, the construction of any boathouse or covered dock structure. 7. The boathouse or covered structure must be so located as to minimize the impact on the view of the adjacent neighbors to the greatest extent practical. BOATHOUSE CRITERIA DOCK EXTENSION SECONDARY CRITERIA Page 32 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 5 of 7 Complete the following for all registered Homeowner / Civic Association(s) that could be affected by this petition and located within 1,000 feet of the subject property. Provide additional sheets if necessary. Information can be found on the Civic Associations and Communities page on the Board of County Commissioner’s website. Applicant is responsible for and shall confirm the current mailing addresses for each association as registered by the Florida Department of State, Division of Corporations. Name of Homeowner/Civic Association: Mailing Address: City: State: ZIP: Name of Homeowner/Civic Association: Mailing Address: City: State: ZIP: Name of Homeowner/Civic Association: Mailing Address: City: State: ZIP: Name of Homeowner/Civic Association: Mailing Address: City: State: ZIP: Name of Homeowner/Civic Association: Mailing Address: City: State: ZIP: ASSOCIATIONS Page 33 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 6 of 7 The following Submittal Requirement Checklist is to be utilized during the Pre-Application Meeting, and at time of application submittal. At time of submittal, the checklist is to be completed and submitted with the application packet. Please provide the submittal items in the exact order listed below, with cover sheets attached to each section. Incomplete submittals will not be accepted or processed. REQUIREMENTS FOR REVIEW REQUIRED NOT REQUIRED Completed Application (download current form from County website) Property Ownership Disclosure Form Affidavit of Authorization, signed and notarized Completed Addressing Checklist Site plan illustration with the following: •Lot dimensions; •Required setbacks for the dock facility; •Cross section showing relation to MHW/MLW and shoreline (bank, seawall, or rip-rap revetment); •Configuration, location, and dimensions of existing and proposed facility; •Water depth where proposed dock facility is to be located; •Distance of navigable channel; •Illustration of the contour of the property; and •Illustration of dock facility from both an aerial and side view. •Roof Structure on Dock Signed and sealed survey Chart of site waterway ADDITIONAL REQUIREMENTS FOR THE PUBLIC HEARING PROCESS: •Following the completion of the review process by County review staff, the applicant shall submit all materials electronically to the designated project manager. •Please contact the project manager to confirm the number of additional copies required. Pre-Application Meeting and Final Submittal Requirement Checklist for: Dock Extension Boathouse Chapter 3 B. of the Administrative Code Page 34 of 99 Boathouse Establishment Petition or Boat Dock Facility Extension (BD) 3/24/24 Page 7 of 7 PLANNERS – INDICATE IF THE PETITION NEEDS TO BE ROUTED TO THE FOLLOWING REVIEWERS: Bayshore/Gateway Triangle Redevelopment: Executive Director Historical Review: Addressing: Parks and Recreation: City of Naples Planning Director: School District (Residential Components): Conservancy of SWFL: Other: Emergency Management: Other: FEE REQUIREMENTS: Boat Dock Extension / Boathouse Petition fee: $1,500.00 Pre-Application Meeting fee $500.00 Estimated Legal Advertising fee for the Office of the Hearing Examiner: $1,125.00 If applicable, an additional fee for Property Owner Notifications will be billed to the applicant after Hearing Examiner hearing date. (Variable) All fees are collected at the time of application. Property Notification Letters, if required by The Land Development Code, will be invoiced after the petition is heard by the Board of County Commissioners. As the authorized agent/applicant for this petition, I attest that all of the information indicated on this checklist is included in this submittal package. I understand that failure to include all necessary submittal information may result in the delay of processing this petition. *Additional fee for the 5th and subsequent re-submittal will be accessed at 20% of the original fee. Signature of Petitioner or Agent Date Printed Name *The completed application, all required submittal materials, and fees shall be submitted to: Growth Management Community Development Department | GMCD Public Portal: https://cvportal.colliercountyfl.gov/cityviewweb Questions? Email: GMDclientservices@colliercountyfl.gov Page 35 of 99 Addressing Checklist 6/14/2024 Page 1 of 2 Growth Management Community Development • Operations & Regulatory Management 2800 North Horseshoe Drive • Naples, FL 34104 • 239-252-2400 • www.colliercountyfl.gov/ Addressing Checklist GMCD Public Portal Land Development Code Administrative Code Please complete the following and upload via the CityView Portal with your submittal. Items marked with a * are required for every application, other items are optional and may not apply to every project. Forms are valid for 6 months following their submittal; an updated form will be required for a new submittal after that timeframe and any time the properties within the project boundary are modified. *Name of Owner/Agent: Firm [if agent]: *Address:*City:*State:*ZIP: *Telephone:Cell:Fax: *E-Mail Address: *Folio (Property ID) Number(s) of the subject property or properties [Attach list if necessary]: *Legal Description of subject property or properties [Attach list if necessary]: Street Address(es) where applicable, if already assigned: Applicant Contact Information Location Information Page 36 of 99 Collier County Addressing Checklist 6/14/2024 Page 2 of 2 Growth Management Community Development • Operations & Regulatory Management 2800 North Horseshoe Drive • Naples, FL 34104 • 239-252-2400 • www.colliercountyfl.gov/ Acceptance of this form does not constitute project and/or street name approval and is subject to further review by the Addressing Official. Pre-approval of project name and/or street name may be requested by contacting us at GMD_Addressing@colliercountyfl.gov or 239-252-2482 prior to your submittal. Current Project Name: Proposed Project Name: Proposed Street Name: Latest Approved Project Number [e.g., SDP-94-##, PPL-2002-AR-####, PL2017000####] Additional documents may be attached to this form and can include. Checkmark the items included with this application: Requirements for Review: Required: LOCATION MAP and/or SURVEY showing the proposed project boundary. ☒ List of additional folio numbers and associated legal descriptions. ☐ E-mail from Addressing Official for any pre-approved project and/or street names.☐ Project Information Submittal Requirement Checklist The completed application, all required submittal materials, and fees shall be submitted to: Growth Management Community Development Department | GMCD Portal: https://cvportal.colliercountyfl.gov/cityviewweb Questions? Email: Front.Desk@colliercountyfl.gov Page 37 of 99 Page 38 of 99 Page 39 of 99 Page 40 of 99 Page 41 of 99 Page 42 of 99 I { l I I ' .l 1 'i :l I I l I I l I AFFIDAVIT OF AUTHORIZATION FOR PETITION NUMBERS($) P La oa. L\ oo l ~ 71 (o 1 / " -k{ of 'fhe. "Ji M Unr o t\ ao~ ~ ,-tr 1 ..v s+- I, VlG-\o< \AO(UV\ (print name), a OS f1'IA.M,C~viM»\«-\ ti..(, (title, 1 ljt\/d. --A-. applicable) of ___________ ~ _______ (company, If applicable), swear or affirm f;)./~ under oath, that I am the (choose one) owner~applicantOcontract purchaserOand that: *Notes: i. I have full authority to secure the approval(s) requested and to impose covenants and restrictions on the referenced property as a result of any action approved by the County in accordance with this application and the Land Development Code; 2. All answers to the questions in this application and any sketches, data or other supplementary matter attached hereto and made a part of this application are honest and true; 3. I have authorized the staff of Collier County to enter upon the property during normal working hours for the purpose of investigating and evaluating the request made through this application; and that 4. The property will be transferred, conveyed, sold or subdivided subject to the conditions and rnstrictions imposed by the ~oved aAtion. ''":" 5. We/I authorize Tu rrtl\, :t~H f tjSSOCAa~ 1 \o( • to act as our/my representative :., any matters regarding this petition including 1 through 2 above. • If the applicar;t is a co1poration, then it is usually executed by the corp. pres. or v. pres. • If the applicant is a Limited Liability Company (L.L.C.) or Limited Company (L.C.), then the documents should typically be s;gned by the Company's "Managing Member." • If the applicant is a partnership, then typically a partner can sign on behalf of the partnership. • If the applicant is a limited partnership, then the general partner must sign and be identified as the "general partner' of the named partnership . .. If the applicant is a trust, then they must include the trustee's name and the words "as trustee". " In each instance, first determine the applicant's status, e.g., individual, corporate, trust, partnership, and then use the appropriate format for that ownership. Under pen;,1\ti2.i; ~;,f pe,·jury, I declare that I have read the foregoing Affidavit of Authorization and that the facts steiH! • • ;, ~~ _"l ( ___ a._l f dl.~:)~-- Slgnature Date ST'.\.TE o::: f ..• ,.t[@Jl\rdi~ COUNTY c+ (IC' i. IIT Fro~ot Tha foregoing i[,s·::-ur,,ant was acknowleged before me by means of ~physical ~resence or r'.lfnline notarization this ~ day of _J_v \~---' 20~ by (printed name of owner or qualifier) \J \ tfur Llnr UV"\ . Su·;:;h ;JE:.-~o):, _,.::tay Public must check applicable box: ~ Are personaiiy known to me [J Has prodL,cea a currem drivers license ------ □ Has producec: . ________ as identification. Notacy Sigoat,,ce, 4L '4;6 ~ CP\08-C'JA-00! i;_t;\!55 :7.EV 3/4/202() Page 43 of 99 Page 44 of 99 Page 45 of 99 Page 46 of 99 Page 47 of 99 Page 48 of 99 Page 49 of 99 Page 50 of 99 Page 51 of 99 Page 52 of 99 Page 53 of 99 Page 54 of 99 Page 55 of 99 Page 56 of 99 Page 57 of 99 Page 58 of 99 Page 59 of 99 Page 60 of 99 Page 61 of 99 Page 62 of 99 Page 63 of 99 Page 64 of 99 Page 65 of 99 Page 66 of 99 Page 67 of 99 Page 68 of 99 Page 69 of 99 Page 70 of 99 Page 71 of 99 Page 72 of 99 Narrative Description: The proposed Boat Dock Extension request is to construct a new single- family docking facility with two boatlifts located at 10 Pelican St. E. on Isles of Capri. The proposed dock facility will be accessory to a new 2-story single-family residence currently being constructed, Building Permit No. PRFH20240728089. The subject waterway is the Big Marco River along the south side of the Isles of Capri. This section of the Big Marco River is considered state lands which also means in this case is located within the Rookery Bay Aquatic Preserve and therefore subject to the associated state of Florida aquatic preserve dock rules. The subject property has approximately 85 linear feet of concrete seawall and sporadic riprap shoreline. Additionally, the subject plated property line is landward of the mean high-water line therefore is the most restrictive point and due to shoreline length, the required setbacks are 15-feet from each property riparian line with Collier County. However, due to being within state lands the required setbacks are 25-feet with the Department of Environmental Protection which is more restrictive. The proposed dock as designed will require a BDE to accommodate the applicant’s 2, 24-foot LOA vessel. Due to the existing site conditions and being located within the aquatic preserve the proposed dock will protrude approximately 32-feet from the property line and therefore the applicant is requesting a 12-foot extension over the allowed 20-feet. The reason for the proposed overall protrusion is due to shallow water depths which the applicant is not allowed to dredge being the subject waterway is classified as a natural waterway located within the aquatic preserve. Dredging is not permitted unless we are able to provide evidence of historic dredging activities that have occurred on-site which, based on our research and state records, have not previously occurred. Additionally, due to the two neighboring dock layouts and locations there were only one dock design option which is to be perpendicular to the seawall with the dock and associated boat slips. The subject waterway is approximately 840-foot wide and as proposed the dock and boat lifts would protrude 4% into the waterway. The subject waterway is a marked waterway but has sufficient depths throughout allowing for safe navigation between docking facilities. Therefore, as proposed there are no impacts to navigation expected within the area as a result from the proposed dock. Furthermore, there are numerous other docking facilities along the same shoreline that protrude much further than the proposed dock. As proposed, the dock will provide the required side yard setback being 15-feet with a 25-feet setback being provided from the east riparian line and a 22-foot setback from the west riparian line which exceeds the county requirement for lots with 60-feet of shoreline or greater. Also, the adjacent landowner to the west has signed a setback waiver to allow the dock to encroach into the state required 25-foot setback. There are no impacts to any submerged resources, the decking area has been minimized and still provides sufficient surface area for recreational activities, routine maintenance, and associated storage. Also, the proposed dock design and overall protrusion are consistent with the other previously approved docking facilities on the subject waterway as there are not many docks designs that are allowed due to the more restrictive aquatic preserve rules. Page 73 of 99 PRIMARY CRITERIA The following criteria, pursuant to LDC section 5.03.06, shall be used as a guide by staff in determining its recommendation to the Office of the Hearing Examiner. The Hearing Examiner will utilize the following criteria as a guide in the decision to approve or deny a particular Dock Extension request. In order for the Hearing Examiner to approve the request, it must be determined that at least 4 of the 5 primary criteria, and at least 4 of the 6 secondary criteria, must be met. On separate sheets, please provide a narrative response to the listed criteria and/or questions. 1. Whether or not the number of dock facilities and/or boat slips proposed is appropriate in relation to the waterfront length, location, upland land use, and zoning of the subject property; consideration should be made of property on unbridged barrier islands, where vessels are the primary means of transportation to and from the property. (The number should be appropriate; typical, single-family use should be no more than two slips; typical multi-family use should be one slip per dwelling unit; in the case of unbridged barrier island docks, additional slips may be appropriate.) The subject property is zoned for a single-family residential unit which warrants no more than 2 slips per CC-LDC. The proposed docking facility consists of installing a new docking facility with two boatlifts, both to accommodate a 24-foot LOA vessel with one being 16’x16’ and the other is a 16’ x 20’ lift. Each lift will have a 2’x16’ catwalk on the outside. The proposed dock will extend out 32-feet from the plated property line which is 12-feet of protrusion past the allowed 20-feet, therefore we are requesting for a 12-foot extension. Additionally, the proposed dock will provide and exceed the required 15-foot setbacks from both riparian lines and therefore will not interfere with the adjacent properties as the vessel’s ingress/egress the proposed boatlifts. As proposed, the docking facility is appropriate for the typical single- family residential use. Criterion Met 2. Whether or not the water depth at the proposed site is so shallow that a vessel of the general length, type, and draft as that described in the petitioner’s application is unable to launch or moor at mean low tide (MLT). (The petitioner’s application and survey should show that the water depth is too shallow to allow launch and mooring of the vessel (s) described without an extension.) The proposed boat dock extension is necessary to extend out to sufficient water depths which is limited by the State’s aquatic preserve rules on the allowed overall protrusion being limited to terminating at the -4’ MLW contour line. Additionally, the aquatic preserve will not allow for any new dredging activities which would limit the overall protrusion to reach greater water depths or create sufficient depths to reduce the overall proposed dock protrusion. Page 74 of 99 Based on the owner’s vessel and existing on-site water depths the BDE is needed to reach sufficient depths as well as to be consistent layout with the two adjacent docks for ease of access as indicated on the attached BDE exhibits. Criterion Met 3. Whether or not the proposed dock facility may have an adverse impact on navigation within an adjacent marked or charted navigable channel. (The facility should not intrude into any marked or charted navigable channel thus impeding vessel traffic in the channel.) The proposed docking facility design is consistent with numerous other existing docking facilities along the subject and adjacent waterways. As proposed, the dock and boatlifts will not impact navigation within the subject waterway nor will it alter the existing ingress/egress to both adjacent neighboring docks and the associated slips. There is a marked channel within the Marco River which provides safe navigation between the markers which are just waterward of the existing docking facilities. Based on this as proposed there are no new impacts to any navigation as a result from the proposed project. Criterion Met 4. Whether or not the proposed dock facility protrudes no more than 25 percent of the width of the waterway, and whether or not a minimum of 50 percent of the waterway width between dock facilities on either side of the waterway is maintained for navigability. (The facility should maintain the required percentages.) The approximate waterway width is 840-feet wide. The proposed dock protrusion is 32-feet which is under 4% width of the waterway. Criterion Met 5. Whether or not the proposed location and design of the dock facility is such that the facility would not interfere with the use of neighboring docks. (The facility should not interfere with the use of legally permitted neighboring docks.) The proposed docking facility design and overall location will not interfere with the existing adjacent docking facilities. As proposed, the dock will be within the allowed buildable area by providing the and exceeding the Collier County required setbacks ensuring no impacts to accessing either adjacent docking facility will result from the proposed dock. Criterion Met Page 75 of 99 SECONDARY CRITERIA 1. Whether or not there are special conditions, not involving water depth, related to the subject property or waterway, which justify the proposed dimensions and location of the proposed dock facility. (There must be at least one special condition related to the property; these may include type of shoreline reinforcement, shoreline configuration, mangrove growth, or seagrass beds.) The special conditions taking into consideration with the proposed dock layout are the two adjacent existing grandfathered docking facilities. Both those docks extend out past the 20-foot mark and the -4’ MLW contour line limiting access to a angled or shore parallel dock design. Additionally, both of the adjacent docks are within the required 15-foot setback line further limiting any dock/slip design that would allow the proposed dock to reduce the overall proposed protrusion and still provide safe access. Criterion Met 2. Whether the proposed dock facility would allow reasonable, safe, access to the vessel for loading/unloading and routine maintenance, without the use of excessive deck area not directly related to these functions. (The facility should not use excessive deck area.) The proposed docking facility and deck area has been minimized to the fullest extent possible and still provides area for routine maintenance, safe access as well as recreational activities like fishing plus storage for these activities. The total over- water square footage is 217 square feet. Criterion Met 3. For single-family dock facilities, whether or not the length of the vessel, or vessels in combination, described by the petitioner exceeds 50 percent of the subject property’s linear waterfront footage. (The applicable maximum percentage should be maintained.) The existing docking facility has been designed with two boatlifts to moor two vessels, being approximately 24-feet in length. The subject property’s shoreline length is approximately 85-feet which the proposed vessel is under 42.5-feet as the PWC’s are not considered vessels by Collier County. Criterion Met 4. Whether or not the proposed facility would have a major impact on the waterfront view of neighboring waterfront property owners. (The facility should not have a major impact on the view of either property owner.) The existing on-site conditions consist of no docking facility but both adjacent neighboring property owners have docks along the subject property shoreline. As Page 76 of 99 proposed the dock has been designed within the designated setbacks and is consistent with the other existing boat docks on the subject waterway. Based on this it’s our opinion that there are no new impacts to either adjacent property owner nor their current view of the subject waterway. Additionally, this is a boating community therefore docks are all part of the overall atmosphere in this community. Criterion Met 5. Whether or not seagrass beds are located within 200 feet of the proposed dock facility. (If seagrass beds are present, compliance with LDC subsection 5.03.06 I must be demonstrated.) There are no seagrass beds present on the property nor the neighboring properties within 200’ of the existing dock structure. Criterion Met 6. Whether or not the proposed dock facility is subject to the manatee protection requirements of LDC subsection 5.03.06 E.11. (If applicable, compliance with subsection 5.03.06.E.11 must be demonstrated.) The proposed work is a single-family dock facility and therefore not subject to Manatee Protection Requirements. N/A Page 77 of 99 STATE OF FLORIDACOUNTY AERIAL VICINITY MAPSTATE OF FLORIDACOUNTY AERIAL VICINITY MAPNOTES:<> THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SUBJECTPROPERTYSUBJECTPROPERTY<> LATITUDE:N 25.976580<> LONGITUDE:W -81.729993SITE ADDRESS:<> 10 PELICAN ST E NAPLES, FL 34113Turrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg LOCATION MAP 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST ELOCATION MAP52RMJ---06-10-25----SHEETS 04-06,10----RMJ----01 OF 10COLLIER COUNTYCOLLIER COUNTYGULF OF MEXICOGULF OF MEXICO8588288641MARCOISLANDEVERGLADESCITY9329846NAPLES90908399483783784129292983983992887846951862I-758486431856850846890896NESWKEY WESTTAMPAFT.MYERSMIAMINAPLESSUBJECTPROPERTYPage 78 of 99 NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 1952 AERIAL 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST E1952 AERIAL52-------------------02 OF 10·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'PROPERTYBOUNDARYPage 79 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW0153060SCALE IN FEETSITE ADDRESS:,10 PELICAN ST ENAPLESFL34113Turrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg EXISTING CONDITIONS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EEXISTING CONDITIONS52-------------------03 OF 10·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'EXISTINGSEAWALLRIPARIAN LINERIPARIAN LINEPROPERTY BOUNDARY85'EXISTING SPORADIC RIPRAP-4' MLWCONTOURLINEEXISTINGADJACENTDOCKEXISTINGADJACENTDOCK20.1'EXISTINGADJACENTLIFT PILES7.5'8.7'20.7'11.7'12'85'115' 115'Page 80 of 99 p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 6/10/2025NESW0102040SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg DOCK PLAN - DIMENSIONS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EDOCK PLAN - DIMENSIONS52----06-10-25----JR----REVISED LIFT----04 OF 10PILE COUNTTYPESIZEQUANTITYWOOD PILE10"6WOOD PILE12"8PILES IN WATER IMPACTS = 10 SF (QTY: 14)EXISTINGSEAWALLRIPARIANLINERIPARIAN LINEPROPERTY BOUNDARY16' x 16'BOAT LIFT30'5'TERMINALPLATFORM(149 SF)-4' MLW CONTOUR LINEEXISTINGADJACENTDOCKEXISTING SPORADIC RIPRAP16' X 20'BOAT LIFT16'20'12'2' x 16' CATWALK16'16'31' 32'4' 24'24'22'22'25'·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:·PROPOSED OVERWATER STRUCTURE (APPX SF):·TOTAL OVERWATER STRUCTURE (APPX SF):·TOTAL PROTRUSION FROM PROPERTY LINE:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'21721732'Page 81 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg 6/10/2025NESW0102040SCALE IN FEETTERMINAL PLATFORMTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg DOCK PLAN - DEPTHS 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EDOCK PLAN - DEPTHS52----06-10-25----JR----REVISED LIFT----05 OF 10EXISTINGSEAWALLRIPARIAN LINERIPARIAN LINEPROPERTY BOUNDARYBOAT LIFT-4' MLW CONTOUR LINEEXISTING SPORADIC RIPRAPAA06BOAT LIFT·SURVEY COURTESY OF:··SURVEY DATED:·THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOTINTENDED FOR CONSTRUCTION USE.·ALL WATER DEPTHS AND DREDGE ELEVATIONS ARE REFERENCED TO MLW·APPLICANT OWNED SHORELINE (APPX LF):·EXISTING OVERWATER STRUCTURE (APPX SF):·WIDTH OF WATERWAY, MHW TO MHW (APPX):·TIDAL DATUM:··MHW (NAVD)=··MLW (NAVD)=NOTES:·PROPOSED OVERWATER STRUCTURE (APPX SF):·TOTAL OVERWATER STRUCTURE (APPX SF):·TOTAL PROTRUSION FROM PROPERTY LINE:"COURT GREGORY SURVEYING. INC."06-17-24-1.60'+0.43'85'0840'21721732'Page 82 of 99 -4.0'- 2 . 0 '0248SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg CROSS SECTION AA 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST ECROSS SECTION AA52----06-10-25----JR----ADDED VESSEL----06 OF 10BIGMARCORIVERFIXEDDOCK16' BOAT LIFTMHW = +0.43' NAVDMLW =-1.60' NAVDALL PILES TO BEWRAPPED FROM 12"ABOVE MHWL TO 6"BELOW SUBSTRATE36"EXISTINGSEAWALL32' PROTRUSION FROMPROPERTY LINEFIXEDACCESSDOCKCATWALK4'PROPERTYLINEPage 83 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg ADJACENT DOCK 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EADJACENT DOCK52-------------------07 OF 10PROPERTYLINENOTE:THE DIMENSIONS SHOWN ARE APPROXIMATEAND ARE TAKEN FROM THE AERIAL IMAGE.32' 70' 63' 56' 66' 54' 82' 71' 71' 147' 47' 50' 34' 51' 33' 29' 43'20'20'Page 84 of 99 -4.0-3.0-2.0-1.7-1.5-2.0-1.5-1.5-1.5-2.0-1.2-2.0-0.2-1.6-2.7-4.0NESW03060120SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg ST OVERLAY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST EST OVERLAY52-------------------08 OF 10STOVERLAYPROPERTYLINEPage 85 of 99 NESW0204080SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg SUBMERGED RESOURCE SURVEY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042-052610 PELICAN ST ESUBMERGED RESOURCE SURVEY52-------------------09 OF 10TYPICAL DIVE TRANSECTNO SEAGRASSES WEREOBSERVED GROWINGWITHIN 200 FT OF THEPROPOSED PROJECTTRANSECTPROPERTYLINE200'200'10' O.C.Page 86 of 99 NESW0100200400SCALE IN FEETTurrell, Hall & Associates, Inc.Email: tuna@thanaples.com3584 Exchange Ave. Naples, FL 34104-3732Marine & Environmental ConsultingPhone: (239) 643-0166Fax: (239) 643-6632REV#:CREATED:DRAWN BY:JOB NO.:SECTION-TOWNSHIP-RANGE-DESIGNED:p:\24042.00 - 10 e pelican st\CAD\PERMIT-COUNTY\24042-BDE.dwg WIDTH OF WATERWAY 6/10/2025THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE.SE1.2.3.4.5.REV BY:DATE:CHK BY:CHANGED:SHEET NO.:RY NO. 5875JRRMJ03-31-2524042RMJ052610 PELICAN ST EWIDTH OF WATERWAY52----06-10-25----JR----REVISED DIMENSION----10 OF 10NOTE:THE DIMENSIONS SHOWN ARE APPROXIMATEAND ARE TAKEN FROM THE AERIAL IMAGE.PROPERTYLINE841' 703' 840'Page 87 of 99 Page 88 of 99 10 PELICAN ST. E. NAPLES, FL 34113 FOLIO #52340640000 SUBMERGED RESOURCE SURVEY REPORT APRIL 2025 PREPARED BY: Page 89 of 99 Table of Contents 1 Introduction ....................................................................................................................................... 1 2 Objective ............................................................................................................................................. 2 3 Methodology ...................................................................................................................................... 3 4 Results ................................................................................................................................................. 4 5 Conclusion .......................................................................................................................................... 5 6 Photos .................................................................................................................................................. 6 Page 90 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 1 1 INTRODUCTION Turrell, Hall & Associates, Inc. (THA) has been contracted to provide environmental permitting services for the proposed dock which includes completing an onsite Submerged Resource Survey (SRS) at the subject property located at 10 Pelican St. E. in Isles of Capri, FL 34113. The subject property can be identified by folio #52340640000. This resource survey provides planning assistance to avoid any potential impacts to submerged resources located in and around the proposed project to both the property owner and regulating agencies during the review process for the proposed docking facility. The subject property consists of a 0.22-acre single-family parcel that can be found on the southwestern side of Isle of Capri just off the Big Marco River. The subject waterway is considered a natural waterway that is located within the Rookery Bay Aquatic Preserve which connects directly to the Gulf of Mexico through the Big Marco River. The upland parcel currently consists of a single-family residence under construction which has an existing vinyl seawall with scattered riprap shoreline. The property is neighbored to the east and west by single family residences, to the south by the subject waterway, and to the north by Pelican St. E. The SRS was conducted on April 3rd, 2025, between 9:00a.m. and 10:30 a.m. Site conditions on that day consisted of mostly clear skies with a southeast breeze approximately 5 mph. Water clarity was good which allowed for approximately 10 inches of visibility. The ambient air temperature was approximately 88 degrees Fahrenheit with an outgoing tide. High tide occurred after the site visit at approximately 3:47 p.m. and reached approximately 2.80 feet above the Mean Low Water Mark. Low tide was achieved during the site visit at approximately 9:54 a.m., reaching approximately 1.6 feet above the Mean Low Water Mark. Page 91 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 2 2 OBJECTIVE The objective of the SRS was to identify and locate any existing submerged resources within 200 feet of the proposed dock project. Ordinarily, if seagrasses are present within the vicinity of a project area, an analysis will be required regarding species, percent coverage, and impacts projected by the proposed project. The presence of seagrasses may be ample cause for re- configuration of the design for projects over surface waters in order to minimize impacts. The general scope of work performed during a typical submerged resource survey is summarized below: • THA personnel will conduct a site visit and swim a series of transects within the project site in order to verify the location of any submerged resources. • THA personnel will identify submerged resources within the vicinity of the site and produce an estimate of the percent coverage of any resources found. • THA personnel will delineate the approximate limits of any submerged resources observed via a handheld GPS device. Page 92 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 3 3 METHODOLOGY THA biologists intentionally designed the methodology of the SRS to cover not only the entire subject property shoreline for the proposed dock but also the area within 200 ft. of the proposed site as required by the Collier County LDC. The components utilized for this survey included: • Reviewing aerial photography of the surveyed area. • Establishing survey transect lines (spaced approximately 10 feet apart) overlaid onto aerials. (See attached Exhibits) • Physically swimming the transects, GPS locating the limits of any submerged resources found, and determining the percent coverage within the area. • Documenting and photographing all findings The surveyed area was evaluated systematically by following the established transect lines throughout the project site as shown on the attached exhibit. Neighboring properties, adjacent docking facilities, and other landmarks provided reference markers which assisted in maintaining correct positioning over each transect. During this SRS, one THA staff member swam the transect lines using snorkel equipment while a second remained on the shoreline and within a kayak taking notes and compiling findings on an aerial of the project site. Ordinarily, if any resources are found, they are photographed, GPS located, delineated, and analyzed for percent coverage within the area via a half meter square quadrat. Page 93 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 4 4 RESULTS The substrate found within the surveyed area consists of silty sand material and shell debris. Depths increased gradually with distance from the shoreline but once past the existing neighboring dock the depths dropped off significantly. During the submerged portion of the survey, no seagrasses, oysters, or other resources were observed in any capacity. Accordingly, no impacts to submerged resources are expected to occur as the result of the proposed project. A list of species observed during the SRS can be seen below in Table 1. Table 1: Observed species of wildlife and vegetation within the vicinity of the project site Common Name Scientific Name Eastern mudminnow Umbra pygmaea Sheepshead Archosargus probatocephalus Common Snook Centropomus undecimalis Gray Snapper Lutjanus griseus Greenback Oncorhynchus clarkii stomias Page 94 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 5 5 CONCLUSION The submerged resource survey was conducted and completed throughout a 200-foot radius surrounding the project site and yielded few results. The two adjacent existing docking facilities and scattered riprap provided surface area for barnacles and a few oysters to grow with numerous fish swimming about. At the time of the survey there were no seagrasses or other marine resources that were observed anywhere within the vicinity of the project site. Based off these observations it is THA opinion that the proposed project will not have any negative impacts to any submerged resources nor the subject waterway water quality. Page 95 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 6 6 PHOTOS Photo 1: View to the South of the subject waterway. Photo 2: View to the West of subject waterway and existing seawall. Photo 3: View to the East of subject waterway. Page 96 of 99 10 Pelican St. E. Submerged Resource Survey April 2025 7 Photo 4, 5 & 6: Typical sediment observed in survey area. Page 97 of 99 1 John Kelly From:John Kelly Sent:Tuesday, August 12, 2025 6:32 PM To:John Kelly Subject:BD-PL20240013776 - 10 Pelican St E - Sign Posting 08122025 Attachments:Sign 1.jpg; Sign 2.jpg I, John Kelly, personally posted a notice of public hearing sign to the front of the subject property, as evidenced by the attached photos, at approximately 2:50 P.M. this date. Respectfully, John Kelly Planner III Zoning Office:239-252-5719 2800 N Horseshoe Dr. Naples, Florida 34104 John.Kelly@colliercountyfl.gov Under Florida Law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Page 98 of 99 Page 99 of 99