Loading...
Backup Documents 08/27/2024 Item #16B 6 (Transportation Solutions & Lighting, Inc.) ORIGINAL DOCUMENTS CHECKLIST & ROUTING SCIE. TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT TO THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGNAT A I',I 2 8 Z024 Print on pink paper. Attach to original document. The completed routing slip and original documents are to be forwarded to the County Attorney Office at the time the item is placed on the agenda. All completed routing slips and original documents must be received in the County Attorney Office no later than Monday preceding the Board meeting. Management **NEW** ROUTING SLIP [ p Complete routing lines#1 through#2 as appropriate for additional signatures,dates,and/or information needed. If the document is already complete w V D 6 the exception of the Chairman's signature,draw a line through routing lines#1 through#2,complete the checklist,and forward to the County Attorney Office. Route to Addressee(s) (List in routing order) Office Initials Date 1. Risk Risk Management 7/20- 2. County Attorney's Office County Attorney Office " (" ` ) 03 h bf 4. BCC Office Board of County J Commissioners C. dy /$( 1(3 4. Minutes and Records Clerk of Court's Office 944 5. Procurement Services Procurement Services PRIMARY CONTACT INFORMATION Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the addressees above may need to contact staff for additional or missing information. Name of Primary Staff Vanessa Diaz/Procurement Contact Information 239-252-8947 Contact/Department Agenda Date Item was August 27, 2024 Agenda Item Number 16.B.6.c Approved by the BCC Type of Document Agreement Number of Original 1 Attached Documents Attached PO number or account N/A 24-8208 Transportation number if document is Transportation Solutions & to be recorded Solutions & Lighting INC. Lighting INC. INSTRUCTIONS & CHECKLIST Initial the Yes column or mark"N/A"in the Not Applicable column,whichever is Yes N/A(Not appropriate. (Initial) Applicable) 1. Does the document require the chairman's original signature STAMP OK N/A 2. Does the document need to be sent to another agency for additional signatures? If yes, N/A provide the Contact Information(Name;Agency;Address;Phone)on an attached sheet. 3. Original document has been signed/initialed for legal sufficiency. (All documents to be VD signed by the Chairman,with the exception of most letters,must be reviewed and signed by the Office of the County Attorney. 4. All handwritten strike-throughs and revisions have been initialed by the County Attorney's N/A Office and all other parties except the BCC Chairman and the Clerk to the Board 5. The Chairman's signature line date has been entered as the date of BCC approval of the VD document or the fmal negotiated contract date whichever is applicable. 6. "Sign here"tabs are placed on the appropriate pages indicating where the Chairman's VD signature and initials are required. 7. In most cases(some contracts are an exception),the original document and this routing slip N/A should be provided to the County Attorney's Office at the time the item is input into SIRE. Some documents are time-sensitive and require forwarding to Tallahassee within a certain time frame or the BCC's actions are nullified. Be aware of your deadlines! 8. The document was approved by the BCC on August 27,2024 and all changes made N/A is not during the meeting have been incorporated in the attached document. The County zeIM/ an option for Attorney's Office has reviewed the changes,if applicable. 7 ( this line. 9. Initials of attorney verifying that the attached document is the version approved by the N/A is not BCC,all changes directed by the BCC have been made,and the document is ready for the iy►, an option for Chairman's signature. 1 this line. 1686 FIXED TERM SERVICE MULTI-CONTRACTOR AWARD AGREEMENT #24-8208 for "TRAFFIC SIGNAL COMPONENTS & HARDWARE" THIS AGREEMENT, made and entered into on this 2. 1 day of 20 Z' , by and between Transportation Solutions & Lighting INC. authorized to do business in the State of Florida, whose business address is 980 N. Federal Hwy., #110, Boca Raton, FL, 33432 _, (the "Contractor") and Collier County, a political subdivision of the State of Florida, (the "County"): WITNESSETH: 1 . AGREEMENT TERM. The Agreement shall be for a one ( 1 ) year period, commencing n upon the date of Board approval; of GA and terminating on one ( 1 ) year(s) from that date or until all outstanding Purchase Order(s) issued prior to the expiration of the Agreement period have been completed or terminated. The County may, at its discretion and with the consent of the Contractor, renew the Agreement under all of the terms and conditions contained in this Agreement for one ( 1 ) additional one ( 1 ) year(s) periods. The County shall give the Contractor written notice of the County's intention to renew the Agreement term prior to the end of the Agreement term then in effect. The County Manager, or his designee, may, at his discretion, extend the Agreement under all of the terms and conditions contained in this Agreement for up to one hundred and eighty (180) days. The County Manager, or his designee, shall give the Contractor written notice of the County's intention to extend the Agreement term prior to the end of the Agreement term then in effect. 2. COMMENCEMENT OF SERVICES. The Contractor shall commence the work upon issuance of a ® Purchase Order ❑Notice to Proceed. 3. STATEMENT OF WORK. The Contractor shall provide services in accordance with the terms and conditions of I I Request for Proposal (RFP) 1111 Invitation to Bid (ITB) n Other ( ITB ) # 24-8208 , including all Attachment(s), Exhibit(s) and Addenda and the Contractor's proposal referred to herein and made an integral part of this Agreement. 1■I The Contractor shall also provide services in accordance with Exhibit A — Scope of Services attached hereto. Page 1 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] IcAo 1686 3.1 This Agreement contains the entire understanding between the parties and any modifications to this Agreement shall be mutually agreed upon in writing by the Parties, in compliance with the County's Procurement Ordinance, as amended, and Procurement Procedures in effect at the time such services are authorized. 3.2 ■ The procedure for obtaining Work under this Agreement is outlined in Exhibit A— Scope of Services attached hereto. n nOther Exhibit/Attachment: 374-n 4. THE AGREEMENT SUM. The County shall pay the Contractor for the performance of this Agreement based on Exhibit B- Fee Schedule, attached hereto and the price methodology as defined in Section 4.1. Payment will be made upon receipt of a proper invoice and upon approval by the County's Contract Administrative Agent/Project Manager, and in compliance with Chapter 218, Fla. Stats., otherwise known as the "Local Government Prompt Payment Act". 4.1 Price Methodology (as selected below): I ecy}: A firm fi ; is authorized. • documentation for the projcct. 1E1 Unit Price: The County agrees to pay a firm total fixed price (inclusive of all costs, including labor, materials, equipment, overhead, etc.) for a repetitive product or service delivered (i.e. installation price per ton, delivery price per package or carton, etc.). The invoice must identify the unit price and the number of units received (no contractor inventory or cost verification). Page 2 of 17 Fixed Term Service Multi-Contractor Agreement [2024_vcr.1] 16B 6 4.2 Any County agency may obtain services under this Agreement, provided sufficient funds are included in their budget(s). 4.3 Payments will be made for services furnished, delivered, and accepted, upon receipt and approval of invoices submitted on the date of services or within six (6) months after completion of the Agreement. Any untimely submission of invoices beyond the specified deadline period is subject to non-payment under the legal doctrine of "laches" as untimely submitted. Time shall be deemed of the essence with respect to the timely submission of invoices under this Agreement. 4.4 The County, or any duly authorized agents or representatives of the County, shall have the right to conduct an audit of Contractor's books and records to verify the accuracy of the Contractor's claim with respect to Contractor's costs associated with any Payment Application, Change Order, or Work Directive Change. 4.5 n TrnTTTavek-and expenses shall be reimbursed as per Section 112.061 Fla. Stats. Mileage • $0.44.5 per mile Breakfast $6:09 i li $4-1--89 DiRReF $4-9.50 Alrfare clams fare Ram • 4 • • long distance charges, fax charges, photocopying charges and postage. Reimbursable undertaken pursuant to this Agreement. 5. SALES TAX. Contractor shall pay all sales, consumer, use and other similar taxes associated with the Work or portions thereof, which are applicable during the performance of the Work. Collier County, Florida as a political subdivision of the State of Florida, is exempt from the payment of Florida sales tax to its vendors under Chapter 212, Florida Statutes, Certificate of Exemption # 85-8015966531C. Page 3 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1 1686 6. NOTICES. All notices from the County to the Contractor shall be deemed duly served if mailed or emailed to the Contractor at the following: Company Name: Transportation Solutions & Lighting INC. Address: 980 N. Federal HWY., #110 Boca Raton, FL 33432 Authorized Agent: Brad Berner Attention Name & Title: VP Telephone: 800-216-4044, ext.1 E-Mail(s): brad@tsandl.us All Notices from the Contractor to the County shall be deemed duly served if mailed or emailed to the County to: Board of County Commissioners for Collier County, Florida Division Director: Jay Ahmad Division Name: Transportation Engineering Address: 2885 South Horseshoe Drive Naples FL 34104 Administrative Agent/PM: Leandro Goicoechea Telephone: 239-252-5178 E-Mail(s): leandro.goicoechea@colliercountyfl.gov The Contractor and the County may change the above mailing address at any time upon giving the other party written notification. All notices under this Agreement must be in writing. 7. NO PARTNERSHIP. Nothing herein contained shall create or be construed as creating a partnership between the County and the Contractor or to constitute the Contractor as an agent of the County. 8. PERMITS: LICENSES: TAXES. In compliance with Section 218.80, F.S., all permits necessary for the prosecution of the Work shall be obtained by the Contractor. The County will not be obligated to pay for any permits obtained by Subcontractors. Payment for all such permits issued by the County shall be processed internally by the County. All non-County permits necessary for the prosecution of the Work shall be procured and paid for by the Contractor. The Contractor shall also be solely responsible for payment of any and all taxes levied on the Contractor. In addition, the Contractor shall comply with all rules, regulations and laws of Collier County, the State of Florida, or the U. S. Government now in force or hereafter adopted. The Contractor agrees to comply with all laws governing the responsibility of an employer with respect to persons employed by the Contractor. Page 4 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 16B6 9. NO IMPROPER USE. The Contractor will not use, nor suffer or permit any person to use in any manner whatsoever, County facilities for any improper, immoral or offensive purpose, or for any purpose in violation of any federal, state, county or municipal ordinance, rule, order or regulation, or of any governmental rule or regulation now in effect or hereafter enacted or adopted. In the event of such violation by the Contractor or if the County or its authorized representative shall deem any conduct on the part of the Contractor to be objectionable or improper, the County shall have the right to suspend the Agreement of the Contractor. Should the Contractor fail to correct any such violation, conduct, or practice to the satisfaction of the County within twenty-four (24) hours after receiving notice of such violation, conduct, or practice, such suspension to continue until the violation is cured. The Contractor further agrees not to commence operation during the suspension period until the violation has been corrected to the satisfaction of the County. 10. TERMINATION. Should the Contractor be found to have failed to perform his services in a manner satisfactory to the County as per this Agreement, the County may terminate said Agreement for cause; further the County may terminate this Agreement for convenience with a thirty (30) day written notice. The County shall be the sole judge of non-performance. In the event that the County terminates this Agreement, Contractor's recovery against the County shall be limited to that portion of the Agreement Amount earned through the date of termination. The Contractor shall not be entitled to any other or further recovery against the County, including, but not limited to, any damages or any anticipated profit on portions of the services not performed. 11. NO DISCRIMINATION. The Contractor agrees that there shall be no discrimination as to race, sex, color, creed or national origin or any other class protected by federal or Florida law. 12. INSURANCE. The Contractor shall provide insurance as follows: A. • Commercial General Liability: Coverage shall have minimum limits of $ 1,000,000 Per Occurrence, $2,000,000 aggregate for Bodily Injury Liability and Property Damage Liability. The General Aggregate Limit shall be endorsed to apply per project. This shall include Premises and Operations; Independent Contractors; Products and Completed Operations and Contractual Liability. B. ■❑ Business Auto Liability: Coverage shall have minimum limits of$ 1,000,000 Per Occurrence, Combined Single Limit for Bodily Injury Liability and Property Damage Liability. This shall include: Owned Vehicles, Hired and Non-Owned Vehicles and Employee Non-Ownership. C. • Workers' Compensation: Insurance covering all employees meeting Statutory Limits in compliance with the applicable state and federal laws. The coverage must include Employers' Liability with a minimum limit of$ 1,000,000 for each accident. Page 5 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 168 6 D. n this insurance. Such insurance shall have limits of not lc: than $ each claim and aggregate. &u • Fr : Coverage G-, El :GeueFage shall have minimum limits of$ per claim. .H- n :-Levee shall have minimum-limits of$ per claim. Special Requirements: Collier County Board of County Commissioners, OR, Board of County Commissioners in Collier County, OR, Collier County Government shall be listed as the Certificate Holder and included as an "Additional Insured" on the Insurance Certificate for Commercial General Liability where required. This insurance shall be primary and non-contributory with respect to any other insurance maintained by, or available for the benefit of, the Additional Insured and the Contractor's policy shall be endorsed accordingly. Current, valid insurance policies meeting the requirement herein identified shall be maintained by Contractor during the duration of this Agreement. The Contractor shall provide County with certificates of insurance meeting the required insurance provisions. Renewal certificates shall be sent to the County thirty (30) days prior to any expiration date. Coverage afforded under the policies will not be canceled or allowed to expire until the greater of thirty (30) days prior written notice, or in accordance with policy provisions. Contractor shall also notify County, in a like manner, within twenty-four (24) hours after receipt, of any notices of expiration, cancellation, non-renewal or material change in coverage or limits received by Contractor from its insurer, and nothing contained herein shall relieve Contractor of this requirement to provide notice. Contractor shall ensure that all subcontractors comply with the same insurance requirements that the Contractor is required to meet. 13. INDEMNIFICATION. To the maximum extent permitted by Florida law, the Contractor shall defend, indemnify and hold harmless Collier County, its officers and employees from any and all liabilities, damages, losses and costs, including, but not limited to, reasonable attorneys' fees and paralegals' fees, whether resulting from any claimed breach of this Agreement by Contractor, any statutory or regulatory violations, or from personal injury, property damage, direct or consequential damages, or economic loss, to the extent caused by the negligence, recklessness, or intentionally wrongful conduct of the Contractor or anyone employed or utilized by the Contractor in the performance of this Page 6 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 1613 6 Agreement. This indemnification obligation shall not be construed to negate, abridge or reduce any other rights or remedies which otherwise may be available to an indemnified party or person described in this paragraph. This section does not pertain to any incident arising from the sole negligence of Collier County. 13.1 The duty to defend under this Article 13 is independent and separate from the duty to indemnify, and the duty to defend exists regardless of any ultimate liability of the Contractor, County and any indemnified party. The duty to defend arises immediately upon presentation of a claim by any party and written notice of such claim being provided to Contractor. Contractor's obligation to indemnify and defend under this Article 13 will survive the expiration or earlier termination of this Agreement until it is determined by final judgment that an action against the County or an indemnified party for the matter indemnified hereunder is fully and finally barred by the applicable statute of limitations. 14. AGREEMENT ADMINISTRATION. This Agreement shall be administered on behalf of the County by the Transportation Engineering Division 15. CONFLICT OF INTEREST. Contractor represents that it presently has no interest and shall acquire no interest, either direct or indirect, which would conflict in any manner with the performance of services required hereunder. Contractor further represents that no persons having any such interest shall be employed to perform those services. 16. COMPONENT PARTS OF THIS AGREEMENT. This Agreement consists of the following component parts, all of which are as fully a part of the Agreement as if herein set out verbatim: Contractor's Proposal, Insurance Certificate(s), Exhibit A Scope of Services, Exhibit B Fee Schedule, ❑ RFP/❑■ ITB/❑ Other #24-8208 , ❑ subsequent quotes, and ❑ Other Exhibit/Attachment: 17. APPLICABILITY. Sections corresponding to any checked box ( ) expressly apply to the terms of this Agreement. 18. SUBJECT TO APPROPRIATION. It is further understood and agreed by and between the parties herein that this Agreement is subject to appropriation by the Board of County Commissioners. 19. PROHIBITION OF GIFTS TO COUNTY EMPLOYEES. No organization or individual shall offer or give, either directly or indirectly, any favor, gift, loan, fee, service or other item of value to any County employee, as set forth in Chapter 112, Part III, Florida Statutes, Collier County Ethics Ordinance No. 2004-05, as amended, and County Administrative Procedure 5311. Violation of this provision may result in one or more of the following consequences: a. Prohibition by the individual, firm, and/or any employee of the firm from contact with County staff for a specified period of time; b. Prohibition by the individual and/or firm from doing business with the County for a specified period of time, Page 7 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 1686 including but not limited to: submitting bids, RFP, and/or quotes; and, c. immediate termination of any Agreement held by the individual and/or firm for cause. 20. COMPLIANCE WITH LAWS. By executing and entering into this Agreement, the Contractor is formally acknowledging without exception or stipulation that it agrees to comply, at its own expense, with all federal, state and local laws, codes, statutes, ordinances, rules, regulations and requirements applicable to this Agreement, including but not limited to those dealing with the Immigration Reform and Control Act of 1986 as located at 8 U.S.C. 1324, et seq. and regulations relating thereto, as either may be amended, as well as the requirements set forth in Florida Statutes, §448.095; taxation, workers' compensation, equal employment and safety including, but not limited to, the Trench Safety Act, Chapter 553, Florida Statutes, and the Florida Public Records Law Chapter 119, if applicable, including specifically those contractual requirements at F.S. § 119.0701(2)(a)-(b) as stated as follows: IT IS THE CONTRACTOR'S DUTY TO PROVIDE PUBLIC RECORDS RELATING TO THIS CONTRACT. IF THE CONTRACTOR HAS QUESTIONS REGARDING THE APPLICATION OF CHAPTER 119, FLORIDA STATUTES, IT SHOULD CONTACT THE CUSTODIAN OF PUBLIC RECORDS AT: Communications, Government and Public Affairs Division 3299 Tamiami Trail East, Suite 102 Naples, FL 34112-5746 Telephone: (239) 252-8999 Email: PublicRecordRequest a(7,colliercountyfl.gov The Contractor must specifically comply with the Florida Public Records Law to: 1. Keep and maintain public records required by the public agency to perform the service. 2. Upon request from the public agency's custodian of public records, provide the public agency with a copy of the requested records or allow the records to be inspected or copied within a reasonable time at a cost that does not exceed the cost provided in this chapter or as otherwise provided by law. 3. Ensure that public records that are exempt or confidential and exempt from public records disclosure requirements are not disclosed except as authorized by law for the duration of the contract term and following completion of the contract if the Contractor does not transfer the records to the public agency. 4. Upon completion of the contract, transfer, at no cost, to the public agency all public records in possession of the Contractor or keep and maintain public records required by the public agency to perform the service. If the Contractor transfers all public records to the public agency upon completion of the contract, the Contractor shall destroy any duplicate public records that are exempt or confidential and exempt from public records disclosure requirements. If the Page 8 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.11 I6B6 Contractor keeps and maintains public records upon completion of the contract, the Contractor shall meet all applicable requirements for retaining public records. All records stored electronically must be provided to the public agency, upon request from the public agency's custodian of public records, in a format that is compatible with the information technology systems of the public agency. If Contractor observes that the Contract Documents are at variance therewith, it shall promptly notify the County in writing. Failure by the Contractor to comply with the laws referenced herein shall constitute a breach of this Agreement and the County shall have the discretion to unilaterally terminate this Agreement immediately. 21. OFFER EXTENDED TO OTHER GOVERNMENTAL ENTITIES. Collier County encourages and agrees to the successful Contractor extending the pricing, terms and conditions of this solicitation or resultant Agreement to other governmental entities at the discretion of the successful Contractor. 22. PAYMENTS WITHHELD. The County may decline to approve any application for payment, or portions thereof, because of defective or incomplete work, subsequently discovered evidence or subsequent inspections. The County may nullify the whole or any part of any approval for payment previously issued and the County may withhold any payments otherwise due to Contractor under this Agreement or any other Agreement between the County and Contractor, to such extent as may be necessary in the County's opinion to protect it from loss because of: (a) defective Work not remedied; (b) third party claims failed or reasonable evidence indicating probable fling of such claims; (c) failure of Contractor to make payment properly to subcontractors or for labor, materials or equipment; (d) reasonable doubt that the Work can be completed for the unpaid balance of the Contract Amount; (e) reasonable indication that the Work will not be completed within the Contract Time; (f) unsatisfactory prosecution of the Work by the Contractor; or (g) any other material breach of the Contract Documents. If any conditions described above are not remedied or removed, the County may, after three (3) days written notice, rectify the same at Contractor's expense. The County also may offset against any sums due Contractor the amount of any liquidated or unliquidated obligations of Contractor to the County, whether relating to or arising out of this Agreement or any other Agreement between Contractor and the County. If a subcontractor is a related entity to the Contractor, then the Contractor shall not mark- up the subcontractor's fees. A related entity shall be defined as any Parent or Subsidiary of the Company and any business, corporation, partnership, limited liability company or other entity in which the Company or a Parent or a Subsidiary of the Company holds any ownership interest, directly or indirectly. 23. • CLEAN UP. Contractor agrees to keep the Project site clean at all times of debris, rubbish and waste materials arising out of the Work. At the completion of the Work, Contractor shall remove all debris, rubbish and waste materials from and about the Project Page 9 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 1 68 6 site, as well as all tools, appliances, construction equipment and machinery and surplus materials, and shall leave the Project site clean. 24. STANDARDS OF CONDUCT: PROJECT MANAGER, SUPERVISOR, EMPLOYEES. The Contractor shall employ people to work on County projects who are neat, clean, well-groomed and courteous. Subject to the American with Disabilities Act, Contractor shall supply competent employees who are physically capable of performing their employment duties. The County may require the Contractor to remove an employee it deems careless, incompetent, insubordinate or otherwise objectionable and whose continued employment on Collier County projects is not in the best interest of the County. 25. IRI WARRANTY. Contractor expressly warrants that the goods, materials and/or equipment covered by this Agreement will conform to the requirements as specified, and will be of satisfactory material and quality production, free from defects, and sufficient for the purpose intended. Goods shall be delivered free from any security interest or other lien, encumbrance or claim of any third party. Any services provided under this Agreement shall be provided in accordance with generally accepted professional standards for the particular service. These warranties shall survive inspection, acceptance, passage of title and payment by the County. Contractor further warrants to the County that all materials and equipment furnished under the Contract Documents shall be applied, installed, connected, erected, used, cleaned and conditioned in accordance with the instructions of the applicable manufacturers, fabricators, suppliers or processors except as otherwise provided for in the Contract Documents. If, within one (1) year after final completion, any Work is found to be defective or not in conformance with the Contract Documents, Contractor shall correct it promptly after receipt of written notice from the County. Contractor shall also be responsible for and pay for replacement or repair of adjacent materials or Work which may be damaged as a result of such replacement or repair. These warranties are in addition to those implied warranties to which the County is entitled as a matter of law. 26. ICI TESTS AND INSPECTIONS. If the Contract Documents or any codes, laws, ordinances, rules or regulations of any public authority having jurisdiction over the Project requires any portion of the Work to be specifically inspected, tested or approved, Contractor shall assume full responsibility therefore, pay all costs in connection therewith and furnish to the County the required certificates of inspection, testing or approval. All inspections, tests or approvals shall be performed in a manner and by organizations acceptable to the County. 27. I■I PROTECTION OF WORK. A. Contractor shall fully protect the Work from loss or damage and shall bear the cost of any such loss or damage until final payment has been made. If Contractor or anyone for whom Contractor is legally liable is responsible for any loss or damage to the Work, or other work or materials of the County or County's separate contractors, Contractor shall be charged with the same, and any monies necessary Page 10 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 16B h to replace such loss or damage shall be deducted from any amounts due to Contractor. B. Contractor shall not load nor permit any part of any structure to be loaded in any manner that will endanger the structure, nor shall Contractor subject any part of the Work or adjacent property to stresses or pressures that will endanger it. C. Contractor shall not disturb any benchmark established by the County with respect to the Project. If Contractor, or its subcontractors, agents or anyone, for whom Contractor is legally liable, disturbs the County's benchmarks, Contractor shall immediately notify the County. The County shall re-establish the benchmarks and Contractor shall be liable for all costs incurred by the County associated therewith. 28. SUBMITTALS AND SUBSTITUTIONS. Any substitution of products/materials from specifications shall be approved in writing by the County in advance. 29. CHANGES IN THE WORK. The County shall have the right at any time during the progress of the Work to increase or decrease the Work. Promptly after being notified of a change, Contractor shall submit an estimate of any cost or time increases or savings it foresees as a result of the change. Except in an emergency endangering life or property, or as expressly set forth herein, no addition or changes to the Work shall be made except upon modification of the Purchase Order by the County, and the County shall not be liable to the Contractor for any increased compensation without such modification. No officer, employee or agent of the County is authorized to direct any extra or changed work orally. Any modifications to this Agreement shall be in compliance with the County Procurement Ordinance and Procedures in effect at the time such modifications are authorized. 30. AGREEMENT TERMS. If any portion of this Agreement is held to be void, invalid, or otherwise unenforceable, in whole or in part, the remaining portion of this Agreement shall remain in effect. 31. ADDITIONAL ITEMS/SERVICES. Additional items and/or services may be added to this Agreement in compliance with the Procurement Ordinance, as amended, and Procurement Procedures. 32. DISPUTE RESOLUTION. Prior to the initiation of any action or proceeding permitted by this Agreement to resolve disputes between the parties, the parties shall make a good faith effort to resolve any such disputes by negotiation. The negotiation shall be attended by representatives of Contractor with full decision-making authority and by County's staff person who would make the presentation of any settlement reached during negotiations to County for approval. Failing resolution, and prior to the commencement of depositions in any litigation between the parties arising out of this Agreement, the parties shall attempt to resolve the dispute through Mediation before an agreed-upon Circuit Court Mediator certified by the State of Florida. The mediation shall be attended by representatives of Contractor with full decision-making authority and by County's staff person who would make the presentation of any settlement reached at mediation to County's board for approval. Should either party fail to submit to mediation as required hereunder, the other party may obtain a court order requiring mediation under section 44.102, Fla. Stat. Page 11 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 16B 6 33. VENUE. Any suit or action brought by either party to this Agreement against the other party relating to or arising out of this Agreement must be brought in the appropriate federal or state courts in Collier County, Florida, which courts have sole and exclusive jurisdiction on all such matters. 34. +s project shall be knowledgeable in their areas of expertise. The County reserves the • The Contractor shall make commercial personnel. 1111 AGREEMENT STAFFING. The Contractor's personnel and management to be utilized for this Agreement shall be knowledgeable in their areas of expertise. The County reserves the right to perform investigations as may be deemed necessary to ensure that competent persons will be utilized in the performance of the Agreement. The Contractor shall assign as many people as necessary to complete required services on a timely basis, and each person assigned shall be available for an amount of time adequate to meet required services. 35. I■1 ORDER OF PRECEDENCE. In the event of any conflict between or among the terms of any of the Contract Documents, the terms of solicitation, the Contractor's Proposal, and/or the County's Board approved Executive Summary, the Contract Documents shall take precedence. II • 36. ASSIGNMENT. Contractor shall not assign this Agreement or any part thereof, without the prior consent in writing of the County. Any attempt to assign or otherwise transfer this Agreement, or any part herein, without the County's consent, shall be void. If Contractor does, with approval, assign this Agreement or any part thereof, it shall require that its Page 12 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 168 6 assignee be bound to it and to assume toward Contractor all of the obligations and responsibilities that Contractor has assumed toward the County. 37. SECURITY. The Contractor is required to comply with County Ordinance 2004-52, as amended. Background checks are valid for five (5) years and the Contractor shall be responsible for all associated costs. If required, Contractor shall be responsible for the costs of providing background checks by the Collier County Facilities Management Division for all employees that shall provide services to the County under this Agreement. This may include, but not be limited to, checking federal, state and local law enforcement records, including a state and FBI fingerprint check, credit reports, education, residence and employment verifications and other related records. Contractor shall be required to maintain records on each employee and make them available to the County for at least four(4)years. All of Contractor's employees and subcontractors must wear Collier County Government Identification badges at all times while performing services on County facilities and properties. Contractor ID badges are valid for one (1) year from the date of issuance and can be renewed each year at no cost to the Contractor during the time period in which their background check is valid, as discussed below. All technicians shall have on their shirts the name of the contractor's business. The Contractor shall immediately notify the Collier County Facilities Management Division via e-mail (DL-FMOPS(a?colliercountyfl.gov) whenever an employee assigned to Collier County separates from their employment. This notification is critical to ensure the continued security of Collier County facilities and systems. Failure to notify within four (4) hours of separation may result in a deduction of$500 per incident. Collier County Sheriff's Office (CCSO) requires separate fingerprinting prior to work being performed in any of their locations. This will be coordinated upon award of the contract. If there are additional fees for this process, the Contractor is responsible for all costs. 38. E■ SAFETY. All Contractors and subcontractors performing service for Collier County are required and shall comply with all Occupational Safety and Health Administration (OSHA), State and County Safety and Occupational Health Standards and any other applicable rules and regulations. Also, all Contractors and subcontractors shall be responsible for the safety of their employees and any unsafe acts or conditions that may cause injury or damage to any persons or property within and around the work site. Collier County Government has authorized the Occupational Safety and Health Administration (OSHA) to enter any Collier County Facility, property and/or right-of-way for the purpose of inspection of any Contractor's work operations. This provision is non- negotiable by any division/department and/or Contractor. All applicable OSHA inspection criteria apply as well as all Contractor rights, with one exception. Contractors do not have the right to refuse to allow OSHA onto a project that is being performed on Collier County Property. Collier County, as the owner of the property where the project is taking place shall be the only entity allowed to refuse access to the project. However, this decision Page 13 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 1 6B 6 shall only be made by Collier County's Risk Management Division Safety Manager and/or Safety Engineer. IN WITNESS WHEREOF, the parties hereto, by an authorized person or agent, have executed this Agreement on the date and year first written above. ATTEST: BOARD OF COUNTY COMMISSIONERS CrystaK Kinzel, Clerk of the Circuit COLLIER CO Y, FLORIDA Court and Comptroller By: - *ct p+ature only o By:nalrman's Chris II , hairman Dated:: (SEAL) Contractor's Witnesses: Transportation Solutions & Lighting INC. Contractor DBA By Contractor's First ess Signaturje A bref4ft ' ue,c,w•-/ VP s-,tca_s 1411Q i I-I(AAA* tType/print signature and titieT tType/print witness namet !tractor's Second Witness Type/print witness namet .• a e s o m and Legality: Cokty Attorney Print Name Name Pagc 14 of 17 Fixed lei m Service Multi-Contractor Agreement [2024,vei%1 I 168 6 Exhibit A Scope of Services X following this page (pages through 23 ) ❑ this exhibit is not applicable Page 15 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.11 16B 6 INVITATION TO BID(ITB)#24-8208 "TRAFFIC SIGNAL COMPONENTS AND HARDWARE" EXHIBIT A SCOPE OF SERVICES DETAILED SCOPE OF WORK: In accordance with Florida Statutes Chapter 316.0745, and in addition to any applicable Federal Highway Administration Manual on Uniform Traffic Control Devices(MUTCD)requirements, all traffic control signals and devices sold or installed in the state of Florida must conform to the Florida Department of Transportation Standard Specifications for Road and Bridge Construction,and be listed on the FDOT Approved Product List,see link below: https://www.fdot.gov/programm anagem ent/productevaluati on/apl/default.shtm https://fdotwpl.dot.state.fi.us/ApprovedProductL ist/Speci fi cations Bid prices shall include delivery to the following address: 2885 South Horseshoe Drive,Naples,Florida 34104. Traffic Signal Heads(Vehicular) CCTO 1502 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: • Signal Head: Three (3) Section Horizontal configuration per MUTCD Part 4, Figure 4D-6 (B —Typical Arrangements) • Visor: Tunnel • Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red,Solid Yellow,Solid Green. • 15-year performance warranty on optical unit. • Color of Signal Head: Black • Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number:650-002-011 12"LED Red Signal: APL Number:650-010-038 12"LED Yellow Signal:APL Number:650-012-023 12"LED Green Signal:APL Number:650-013-026 CCTO 1506 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Signal Head: Three(3) Section Horizontal configuration per MUTCD Part 4, Figure 4D-10 (B—Typical Arrangements) b. Visor: Tunnel c. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Green. d. 15-year performance warranty on optical unit. e. Color of Signal Head: Black f. Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number:650-002-011 12"LED Arrow Red Signal:APL Number:650-011-027 12"LED Arrow Yellow Signal:APL Number:650-014-019 12"LED Arrow Green Signal:APL Number: 650-015-019 CCTO 1509 1 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Signal Head: Four (4) Section Horizontal configuration per MUTCD Part 4, Figure 4D-12 (B —Typical Arrangements) b. Visor: Tunnel c. Optical Unit: Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Yellow, Arrow Green. d. 15-year performance warranty on optical unit. e. Color of Signal Head: Black f. Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number: 650-002-011 12"LED Arrow Red Signal:APL Number: 650-011-027 12"LED Arrow Yellow Signal:APL Number:650-014-019 12"LED Arrow Green Signal:APL Number: 650-015-019 CCTO 1510 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Signal Head: Five (5) Section Horizontal configuration per MUTCD Part 4, Figure 4D-11 (B —Typical Arrangements) b. Visor: Tunnel c. Optical Unit: Light Emitting Diode (LED) 12-inch Diameter, Solid Red, Solid Yellow, Arrow Yellow, Arrow Green,&Solid Green. d. 15-year performance warranty on optical unit. e. Color of Signal Head: Black f. Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number: 650-002-011 12"LED Red Signal:APL Number: 650-010-038 12"LED Yellow Signal:APL Number: 650-012-023 12"LED Arrow Yellow Signal:APL Number:650-014-019 12"LED Arrow Green Signal:APL Number:650-015-019 12"LED Green Signal:APL Number:650-013-026 CCTO 1511 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Signal Head: Four (4) Section Vertical configuration per MUTCD Part 4, Figure 4D-12 (B — Typical Arrangements) b. Visor: Tunnel c. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Yellow, Arrow Green. d. 15-year performance warranty on optical unit. e. Color of Signal Head: Black f. Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number:650-002-011 12"LED Right Arrow Red Signal:APL Number: 650-011-027 12"LED Right Arrow Yellow Signal:APL Number: 650-014-019 12"LED Right Arrow Green Signal:APL Number: 650-015-019 CCTO 1512 2 I 6 4 Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Signal Head:Five(5)Section Vertical Cluster configuration per MUTCD Part 4,Figure 4D-11 (B—Typical Arrangements) b. Visor: Tunnel c. Optical Unit: Light Emitting Diode (LED) 12-inch Diameter, Solid Red, Solid Yellow, Solid Green & Arrow Yellow,Arrow Green. d. 15-year performance warranty on optical unit. e. Color of Signal Head: Black f. Material:Aluminum Ordering Number Logic: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 12"Die Cast Vehicle Signal:APL Number:650-002-011 12"LED Red Signal:APL Number:650-010-038 12"LED Yellow Signal:APL Number:650-012-023 12"LED Green Signal:APL Number:650-013-026 12"LED Arrow Yellow Signal:APL Number: 650-014-019 12"LED Arrow Green Signal:APL Number: 650-015-019 CCTO 1513(solid) Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List: a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red,Solid Yellow,Solid Green. b. 15-year performance warranty on optical unit. 1) Ordering Number Logic: CCTO 1513-R 12"Dialight LED Red Signal or approved equivalent APL Number: 650-010-038 2) Ordering Number Logic: CCTO 1513-Y 12"Dialight LED Yellow Signal or approved equivalent APL Number: 650-012-023 3) Ordering Number Logic: CCTO 1513-G 12"Dialight LED Green Signal or approved equivalent APL Number: 650-013-026 CCTO 1513(Arrow) Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List: a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Green. b. 15-year performance warranty on optical unit. 4) Ordering Number Logic: CCTO 1513a-RA 12"Dialight LED Arrow Red Signal or approved equivalent APL Number: 650-011-027 5) Ordering Number Logic: CCTO 1513a-YA 12"Dialight LED Arrow Yellow Signal or approved equivalent APL Number:650-014-019 6) Ordering Number Logic: CCTO 1513a-GA 12"Dialight LED Arrow Green Signal or approved equivalent APL Number:650-015-019 CCTO 1513(U-Turn) Signal,Vehicle Traffic Control LED inserts per the following: a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,U-Turn Red,U-Turn Yellow,U-Turn Green. b. 15-year performance warranty on optical unit. 7) Ordering Number Logic: CCTO 1513b-RU 12"Dialight LED U-Turn Red Signal or approved equivalent 8) Ordering Number Logic: CCTO 1513b-YU 12"Dialight LED U-Turn Yellow Signal or approved equivalent 9) Ordering Number Logic: 3 I686 CCTO 1513b-GU 12"Dialight LED U-Turn Green Signal or approved equivalent CCTO 1513(12 Volt) Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List: a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red and Solid Yellow. b. Operating Voltage: 10-30V DC optical unit. c. Lens Type:Tinted 10)Ordering Number Logic: CCTO 1513-RF 12" Dialight 10-30 V DC LED Red Signal, Part Number: 433-1210-005XL or approved equivalent 11) Ordering Number Logic: CCTO 1513-YF 12"Dialight 10-30 V DC LED Yellow Signal, Part Number: 433-3230-905XL or approved equivalent CCTO 1532—Visors/Louvers Signal Visor,Vehicle Traffic Control per the following and per State of Florida Approved Products List: a. Type:Tunnel b. Color:Flat Black c. Size: 12 inch d. Material:Aluminum Ordering Number Logic: Mobotrex housing Visor or approved equivalent APL Number:650-002-011 Traffic Signal Back Plates CCTO 3002 Backplates, Eagle Horizontal 1-Section Eagle Signal Flead per the following and per State of Florida Approved Products List: a. Louvered with 2"Reflective 3M Tape b. Material:Aluminum c. Color:Black d. Number of Sections: 1 e. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3002 Transportation Control Systems Part No.BP-5001B-F or approved equivalent APL Number:650-022-004 CCTO 3004 Backplates, Eagle Horizontal 2-Section Signal Head per the following and per State of Florida Approved Products List: a. Louvered with 2"Reflective 3M Tape b. Material:Aluminum c. Color:Black d. Number of Sections:2 e. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3004 Transportation Control Systems Part No BP-5002B-F.or approved equivalent APL Number:650-022-004 CCTO 3008 Back plates, Eagle Horizontal 3-Section Signal Head per the following and per State of Florida Approved Products List: a. Louvered with 2"Reflective 3M Tape b. Material:Aluminum c. Color:Black d. Number of Sections:3 4 1 6 B 6 e. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3008 Transportation Control Systems Part No.BP-5003B-F or approved equivalent APL Number: 650-022-004 CCTO 3010 Backplates, Eagle Horizontal 4-Section Signal Head per the following and per State of Florida Approved Products List: a. Louvered with 2"Reflective 3M Tape b. Material:Aluminum c. Color:Black d. Number of Sections:4 e. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3010 Transportation Control Systems Part No.BP-5004B-F or approved equivalent APL Number: 650-022-004 CCTO 3012 Back plates,Horizontal 5-Section Signal Head per the following and per State of Florida Approved Products List: a. Louvered with 2"Reflective 3M Tape b. Material:Aluminum c. Color:Black d. Number of Sections:5 e. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3012 Transportation Control Systems Part No.BP-5005B-F or approved equivalent APL Number: 650-022-004 CCTO 3014 Backplates,Vertical 5-Section Signal Head per the following and per State of Florida Approved Products List: a. Cluster Mast Arm Mount b. Louvered with 2"Reflective 3M Tape c. Material:Aluminum d. Color:Black e. Number of Sections:5 f. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3014 Transportation Control Systems Part No.BP-5007B-F or approved equivalent APL Number: 650-022-004 CCTO 3016 Backplates,Cluster 5-Section Signal Head per the following and per State of Florida Approved Products List: a. Cluster Span Wire Mount b. Louvered with 2"Reflective 3M Tape c. Material:Aluminum d. Color:Black e. Number of Sections:5 f. Signal Head Type:Aluminum Ordering Number Logic: CCTO 3016 Transportation Control Systems Part No.BP-5021B-F or approved equivalent APL Number: 650-022-004 Traffic Signal Heads(Pedestrian) CCTO 1540 Signal,Pedestrian Traffic Control per the following and per State of Florida Approved Products List: 5 1686 a. Housing: 16"X 18" b. Material:Die Cast Aluminum c. Color:Flat Black d. Optical Unit:LED e. Includes Countdown Feature f. Symbol:Filled Icon Hand and Person 16"X 18"Module 9"x 3 '/"Digits w/Class 3 Message Size(11"x7") g. Symbol:Full Hand&Full Person with egg crate type visor Ordering Number Logic: Mobotrex housing Model SG7SZ20C3FFF10-21 or approved equivalent &Dialight Corporation,Model 430- 6479-805XF or approved equivalent Mobotrex Pedestrian housing: APL Number:653-024-002 Dialight Countdown Pedestrian Module APL Number:653-022-014 CCTO 1542 Signal,Pedestrian Traffic Control Module per the following and per State of Florida Approved Products List: a. Optical Unit:LED Single module b. Symbol:Filled Icon Hand and Person 16"Module 9"x 3 '/<"Digits w/Class 3 Message Size(11"x7") c. Includes Countdown Feature d. Symbol:Full Hand&Full Person. Ordering Number Logic: Dialight Corporation.Model 430-6479-805XF or approved equivalent APL Number: 653-022-014 Signal Head Auxiliaries(Vehicular and Pedestrian Signals) CCTO 2922 Mast Arm Bracket Kits Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: a. Material:Aluminum b. Hardware:Stainless Steel c. Number of cables: 1 d. Cable Length:Minimum 120 inches Ordering Number Logic: CCTO 2922g Pelco Products, Inc., Model Number: SP-1006-FL-3-120-PNC (3-section) or approved equivalent APL Number: 659-031-011 CCTO 2922h Pelco Products, Inc., Model Number: SP-1006-FL-4-120-PNC (4-section) or approved equivalent APL Number:659-031-011 CCTO 2922i Pelco Products,Inc.,Model Number:SP-1006-FL-5-120-PNC(5-section)or approved equivalent APL Number: 659-031-011 CCTO 2908a Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: a. Material:Aluminum b. Hardware: Stainless Steel c. Number of cables: 1 d. Cable Length:Minimum 120 inches to minimum 144 inches Ordering Number Logic: CCTO 2908a Pelco Products,Inc.Model Number:SP-1079-FL-120-PNC or approved equivalent APL Number:659-031-009 6 ter._ 1 68 6 CCTO 2928 Clamp Mount Assembly Mast arm Astro-Brac Steller Articulating clamp Mount Assembly per the following and per State of Florida Approved Products List: a. Bracket Articulated Mounting. b. Finish:Standard c. Hardware:Stainless Steel d. Cable Length:Minimum 96"TO 120" Ordering Number Logic: CCTO 2928a Pelco Products,Inc.,Part No.SP-1118-FL-96-PNC or approved equivalent APL Number:659-031-019 CCTO 2928b Pelco Products,Inc.,Part No. SP-1118-FL-120-PNC or approved equivalent APL Number: 659-031-019 CCTO 2926 Hanger Assembly,Tri-Stud per the following and per State of Florida Approved Products List: a. Span Wire Clamp,Aluminum b. Cast Aluminum Upper and Lower Hanger c. Includes Stainless Steel Hardware Ordering Number Logic: Pelco Products,Inc.,Part No. SP-1050-FL-PNC or approved equivalent APL Number:659-037-003 CCTO 2924 Hanger,Disconnect per the following and per State of Florida Approved Products List: a. Door:Single Door b. Material: Cast Aluminum with Stainless Steel Hardware. c. Top:Non-Threaded Top&Tri-Stud Hub d. Side Entrance Cover:Neoprene Grommet. e. Color: Flat Black f. Include Disconnect Hub Assembly,Tri-Stud g. Exclude Terminal Block&Harness Assemblies Ordering Number Logic: Pelco Products Inc.,Part No.: SP-1021-FL-2-P34 or approved equivalent APL Number:659-004-018 CCTO 2940 Bracket Assembly,Tri-Stud Upper Arm per the following and per State of Florida Approved Products List: a. Direction: 2-Way b. Material:Aluminum c. Tri-stud kit Material:Stainless Steel. d. Color:Flat Black Ordering Number Logic: Pelco Products,Inc.,Part No. SP-1026-FL-P34 or approved equivalent APL Number: 659-001-030 CCTO 2942 Bracket Assembly,Single Stud Lower Arm per the following and per State of Florida Approved Products List. a. Direction: 2-Way b. Material:Aluminum c. Hardware Kit Material: Stainless Steel. d. Color: Flat Black Ordering Number Logic: Pelco Products,Inc.Part No.SP-1027-FL-P34 or approved equivalent APL Number: 659-001-031 7 _. I686 CCTO 1602 Pedestrian Bracket Assemblies—Upper Tri-Stud,Aluminum side of pole-per the following and per State of Florida Approved Products List: a. Tri-Stud Upper Arm Assembly b. 1-way,Aluminum c. Stainless Steel Fasteners d. Color:Black Ordering Number Logic: Pelco Products Inc.Part Number:SP-1011-FL-P34 or approved equivalent APL Number: 653-001-004 CCTO 1604 Pedestrian Bracket Assemblies, Lower Tri-Stud Aluminum side of pole, per the following and per State of Florida Approved Products List: a. Tri-Stud Lower Arm Assembly b. 1-way,Aluminum c. Stainless Steel Fasteners d. Color:Black Ordering Number Logic: Pelco Products Inc.Part Number:SP-1012-FL-P34 or approved equivalent APL Number:653-001-003 CCTO 1518 Closure Assembly,Vehicle Traffic Control Signal per the following and per State of Florida Approved Products List: Signal head closure kit Ordering Number Logic: TO 1518:Pelco Products,Inc. SE-3054-P02 or approved equivalent CCTO 2952 Post Top Adapter(Slip Fitter),Pedestrian Traffic Control Signal per the following and per State of Florida Approved Products List a. Aluminum Tri-Stud Adapter for use with 4-1/2 inch OD Aluminum Pole b. Fasteners:Stainless Steel c. Color:Natural Ordering Number Logic: CCTO 2952 Pelco Products,Inc.Part No.,EC-3004-T-PNC or approved equivalent APL Number:659-009-001 CCTO 2954c Pole,Spun Aluminum,Schedule 40,per the following and per State of Florida Approved Products List: a. Size:4.5 inch OD b. Length:7' c. Material:Aluminum d. Threaded:One End e. Finish:Natural Ordering Number Logic: CCTO 2954c Pelco Products,Inc.Part No.,PB-5100-7-PNC or approved equivalent CCTO 2959 Sign Mountings per the following and per State of Florida Approved Products List: e. Anchor Bolt Sets f. Quantity:Set of 4 g. Anchor bolt Size: 3/4"-IONC h. Length: 18" i. Paint:None j. Exterior:Galvanized 8 686 k. Includes 4 each:Bolts,Washers and Nuts Ordering Number Logic: Pelco Products Inc.,Part Number: PB-5543-GLV CCTO 2960 Pedestal Base,Aluminum,per the following and per State of Florida Approved Products List: a. Size: 13-5/8 inches x 13-5/8 inches x 15 inches high per the following: b. Material:Aluminum with plastic Door c. Threaded for 4.5-inch OD aluminum pole d. Finish:Natural e. Include grounding lug f. No set screws in collar Ordering Number Logic: Pelco Products,Inc.Part No. SP-1116-FL-GL-PNC or approved equivalent APL Number:646-001-001 CCTO 2962 Collar Assy.,Square Base,Aluminum,per the following and per State of Florida Approved Products List: a. Finish:Natural Ordering Number Logic: Pelco Products,Inc.Part No.PB-5325-PNC or approved equivalent APL Number:646-001-005 CCTO 2981b Sign Hanger Assembly, Mast arm, and Free-Swinging Cable Mount per the following and per State of Florida Approved Products List. Mast Arm Mini-Brac Mount Cable Length: 84";Paint no color Ordering Number Logic: TO 2981b:Pelco Products,Inc.Part No.: SP-1072-FL-84-PNC or approved equivalent CCTO 2984 Traffic Signal Hardware, Components, Pipe Fittings per the following and per State of Florida Approved Products List: a. 1'/2"Grommet,Neoprene w/Diaphragm for disconnect cable openings b. Color:Black Ordering Number Logic: Pelco Products Inc.Part No.SE-0449-PNC or approved equivalent CCTO 2986 Traffic Signal Hardware, Components, Pipe Fittings per the following and per State of Florida Approved Products List: a. Double Serrated Lock ring,Aluminum Ordering Number Logic: Pelco Products Inc.Part No.SE-0451-PNC or approved equivalent CCTO 2994 Traffic Signal Hardware,Extension(Extender)per the following and per State of Florida Approved Products List: a. Material:Aluminum b. Length:72 inches Ordering Number Logic: Pelco Products Inc.Part No.SE-0507-72-PNC or approved equivalent APL Number:659-015-003 CCTO 3030 Pole Cap per the following and per State of Florida Approved Products List: a. Acorn Type 9 , A8b , b. Material:Aluminum c. For 4-1/2"O.D.Pole d. Fasteners:Stainless Steel e. Paint:None Ordering Number Logic: Pelco Products Inc.,Part Number:PB-5401-PNC or approved equivalent APL Number:746-001-009 CCTO 3126 Utility Pole Hardware per the following: a. 7/8"Fiberglass Insulator Minimum Strength(lb)-36,000 b. 7/8"Rod Diameter,Rod Length 120"(10ft),End Fittings-Clevis w/Roller-Clevis-Clevis-2 Roller Ordering Number Logic: Ordering Number Logic:TO 3126 Hubbell Power Systems:Model: GS36120CC2 Detection(Pedestrian Detection System) CCTO 1806 Pushbutton, Pedestrian Detector (Momentary LED Model) per the following and per State of Florida Approved Products List: a. Minimum 2-inch Actuator,A.D.A.Compliant. b. Operating Force:2 lbs. Maximum c. Operating Voltage: 12-36VDC or 9-25VAC RMS d. On Resistance: 85 S2 Typical. e. Operating Mode:Approx.0.025 sec flash each time button is pressed. f. Viewing Angle: 155° Ordering Number Logic: Polara Bulldog III BDL3-B or approved equivalent CCTO 1808 Pushbutton, Pedestrian Detector, Aluminum Push Button Cup,per the following and per State of Florida Approved Products List: a. Aluminum cup for mounting the BullDog Pedestrian Detector. b. Color:Black Ordering Number Logic: Polara Aluminum Push Button Cup APBC2-B or approved equivalent CCTO 1812 Pushbutton, Pedestrian Detector, Audible/Tactile Pedestrian Detector with Pedestrian Station Monitor, per the following and per State of Florida Approved Products List: a. Push Button:ADA Compliant,raised tactile arrow on button,solid state switch rated to 20 million actuations minimum. b. Construction:Die-cast aluminum,powder coated Black c. Confirmation of button push via latching LED,sound,and vibrotactile bounce. d. Direction of travel(with extended button push). e. Standard locating tone during Don't Walk(and clearance if desired). f. Cuckoo,chirp,or standard voice message during walk. g. Vibrating button during walk. h. Standard locating tone,custom sound,or verbal countdown during PED clearance. i. All sounds automatically adjust to ambient over 60dB range. j. Most sounds can have minimum and maximum volume independently set. k. All sounds are synchronized. 1. Extended button push can turn on,boost volumes,and/or mute all sounds except those on activated crosswalk. m. Special emergency messages available. n. Custom locating tone o. Informational message 10 t 68 6 p. Custom walk sounds/message q. Custom clearance sound r. Multiple languages(up to three,selectable by user) s. 9"x15"MUTCD R10-3e pedestrian sign(Option A) Ordering Number Logic: Polara 2 Wire Navigator Push Button Station EN23TN1-B or approved equivalent APL Number:665-004-004 Detection(Inductive Loop Detector) CCTO 1704 Detector,Dual Channel Rack Mount Loop with Delay&Extend Detection per the following and per State of Florida Approved Products List: Inductive loop detectors shall meet the following specifications a. Back-lit LCD screen that displays complete detector status and function settings. b. TrueCount version(Model 1201 Only)provides 97%to 99%count accuracy when used with either a single long loop or multiple 6'x 6' loops connected together. c. Audible detect signal(buzzer)facilitates loop and/or detector troubleshooting. d. Upgrades or addition of user specific options are accomplished by changing the socket mounted processor. e. Push button programming. f. All programmed detector parameters are stored in non-volatile memory. g. Directional logic capability. Ordering Number Logic: CCTO 1704 Eberle Design Inc.,Reno A&E,Part No.C-1200 Type C with timings or approved equivalent APL Number:660-017-003 Traffic Controller CCTO 2010 Controller,Traffic NEMA TS2,Type 2 per the following and per State of Florida Approved Products List: a. Intelight X3 NEMA TS2,Type 2 b. NEMA MSA,MSB,MSC,and MSD Connectors c. Meet current ATC 5201 and 5401,NEMA TS-1 and TS-2,and NTCIP standards. d. Compliant with current ATC 5.2b standards e. Number Of Phases:40 f. Compatible with the existing Collier County Intelight Maxview Communications System. Ordering Number Logic: Intelight X3 or approved equivalent APL Number: 67l-017-013 Controller Cabinet Assembly CCTO 2102 Cabinet,Traffic Signal Controller Assembly per the following and per State of Florida Approved Products List: a. NEMA Standard TS2 Type 1 b. Collier County TS2-TYPE 1 Specification. c. Cabinet assembly shall be Type 6 d. Cabinet Assembly shall include front and rear access doors. e. 10 Circuit SDLC Interface panel. f. Exclude Traffic Controller,M.M.U.&Loop Detectors. g. 2 detector racks with total 32 channels of detection capability. h. Hard wired inductive loop detector panel. i. 8 vehicle and 8 pedestrian test switches. j. Shall include NEMA TS2 Type 1 power supply with minimum 5.0 amp, 12 volt AC output 11 • 16B 6 k. 8 flash transfer relay sockets,includes relays. 1. 3 shelves with document drawer on lower shelf. m. Plexiglas covered cabinet window for Photocell control panel with an on/off/auto test switch, Square D contactor model number: 8910DPA42V02, (L1 wired to Illuminated signage and L2 wired to Street Lighting),Square D 10 Amp circuit breaker for Illuminated Signage, and Square D 20 Amp circuit breaker for street lighting. n. Plexiglas Hinged Flip-up Cover for Technician Test Switches. o. Cabinet interior illumination shall be L.E.D. located in top portion of cabinet interior and under document door. p. Base mounted cabinet. q. Technician panel shall include stop time on/off/auto switch(off position shall be momentary) r. UPS interface panel s. Cabinet shall meet current Collier County Technical Special Provisions(See http://www.colliergov.net/Index.aspx?page=2186) Ordering Number Logic: Transportation Control Systems Inc.,TS2-Type 1 Collier County or approved equivalent APL Number: 676-034-003 Controller Accessories CCTO 2105 Cabinet,Traffic Signal Controller Assembly Power Connector Adapter Cable from TS2,Type 1 to TS2,Type 2 Traffic Controller. Ordering Number Logic: Temple,Inc Part Number:ABW 12027P001 or approved Equivalent APL Number: 676-034-001 CCTO 2206a Cabinet Power Supply,TS-2 per the following and per State of Florida Approved Products List: a. Input:89-135 VAC b. +12 VDC @ 5.0 Amps c. +24 VDC @ 3.0 Amps d. 12 VAC @ 0.25 Amps Ordering Number Logic: Eberle Design Inc.,Part No.EDI PS-250 or approved equivalent APL Number: 678-017-003 CCTO 2223 SmartMonitor Program Card, Malfunction Management Unit (MMU2) per the following and per State of Florida Approved Products List: a. Type:TS2 b. Number of Program Channels: 16 c. On-board non-volatile memory device d. Compatible with MMU2-16LE(ip)s Ordering Number Logic: Eberle Design Inc.,MMU2-16LE(ip)SmartMonitor Program Card or approved equivalent APL Number: 678-016-005 CCTO 2224 NEMA Load Switch per the following and per State of Florida Approved Products List: a. Solid State b. Three(3)Independent switching circuits c. Rated at 10A per circuit d. Cinch-Jones socket S-2412SB,or equivalent. Ordering Number Logic: Power Distribution&Control,Inc.,Part No.SSS-86-3 or approved equivalent 12 I686 APL Number: 678-004-009 CCTO 2226 NEMA Flasher per the following and per State of Florida Approved Products List: a. Type 3 b. Rated at 20 A per circuit. Ordering Number Logic: Power Distribution&Control,Inc.,Part No.SSF-86-3 or approved equivalent APL Number:678-007-007 CCTO 2227 Flasher Relay AI DC per the following and per State of Florida Approved Products List: Ordering Number Logic: Ordering Number Logic: AI 900-010 or approved equivalent CCTO 2228 Bus Interface Unit(BIU)per the following and per State of Florida Approved Products List: a. Meet or exceed all requirements of NEMA Standard TS2 for BIU Configuration. Ordering Number Logic: Eberle Design Inc.,Model:BIU-700 or approved equivalent APL Number: 678-018-003 CCTO 2110 4 11/16 inch Square Axial Fan per the following: a. Fan Voltage: 115 VAC b. Electrical Connections:Terminals. c. Bearings:Ball d. Rating:Minimum 100 cubic feet per minute Ordering Number Logic: Dayton Part Number 2RTK6 or approved equivalent CCTO 2112 Low Voltage Surge Protector, Isolated Pedestrian Circuit Protector per the following and per State of Florida Approved Products List: a. Peak Surge Current: 10 kA(8 x 20 µs) b. Voltage Clamp: 30 volts Ordering Number Logic: CCTO 2112 Asco Power Technologies,Surge Protector,Model: 175D030S 10KLPCNO(Edco PC642C-030)or approved equivalent APL Number: 676-004-010 Ordering Number Logic: CCTO 2112a Asco Power Technologies, Base, Model: PCB1B (Edco PCB1B-WKEY) or approved equivalent APL Number: 676-004-010 CCTO 2113 10 Circuit SDLC Hub per the following and per State of Florida Approved Products List: a. Compatible with NEMA TS2-Type 1 controller Assembly b. Number of SDLC communication ports: 10 Ordering Number Logic: Transportation Control Systems Inc., TS2 Traffic Signal Cabinet, 10 circuit, SDLC Hub or approved equivalent APL Number:676-034-003 CCTO 2302 Flash Transfer Relay per the following and per State of Florida Approved Products List: 13 1 68 6 a. Meet NEMA Standard TS 2-2003 b. Pole Configuration:DPDT c. Coil Input Voltage: 110/120 VAC 50/60 Hz d. Contact Load Rating:20 Amps at 120 VAC Ordering Number Logic: Deltrol Controls,Model:295 or approved equivalent APL Number:678-005-008 CCTO 2118 Filter,Traffic Cabinet AC Power Line per the following and per State of Florida Approved Products List: a. 120VAC,60A,50/60Hz b. UL 1283 Compliant Ordering Number Logic: Asco Power Technologies,Model: 250120NF060AN3N0(Edco INXT120NL000-1)or approved equivalent CCTO 2202 NEMA TS2 Type-1 Load Bay circuit L-board per the following and per State of Florida Approved Products List: a. Manufacturer:Eagle Ordering Number Logic: Mobotrex,Part Number:ACP11957P001 or approved equivalent CCTO 2208 Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List: a. Housing and Circuitry for one(1)BIU and 8 Two Channel Detector Cards b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs c. Dimensions: 14.6"W x 5.4"H x 7.5"D Ordering Number Logic: Mobotrex,Part Number:CDR100 or approved equivalent APL Number:676-028-001 CCTO 2210 Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List: a. Housing and Circuitry for one(1)BIU and 4 Two Channel Detector Cards. b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs c. Dimensions:9.8"W x 5.9"H x 7.1"D Ordering Number Logic: Mobotrex,Part Number:CDR101 or approved equivalent APL Number:676-028-001 CCTO 2212 Rack TS2,Eagle Cabinet Detector per the following and per State of Florida Approved Products List: a. Housing and Circuitry for one (1) BIU, 8 Two Channel Detector Cards, and one (1) GTT Opticom Phase Selector Card. b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs c. Dimensions: 17.0"W x 5.9"H x 7.1"D Ordering Number Logic: Mobotrex,Part Number:AAD12047P001 or approved equivalent APL Number: 676-028-001 CCTO 2214 Rack TS2,TCS Cabinet Detector per the following and per State of Florida Approved Products List: a. Housing and Circuitry for one (1) BIU, 8 Two Channel Detector Cards, and one (1) GTT Opticom Phase Selector Card. b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs c. Dimensions: 17.0"W x 5.9"H x 7.1"D Ordering Number Logic: 14 • j i686 TCS,Part Number:TCS-413 or approved equivalent APL Number: 676-028-001 CCTO 2111 Inductive Loop Panel,TS2,Cabinet Detector per the following and per State of Florida Approved Products List: a. PCB for 16 channels(1-16)of inductive loop detection. b. PCB for 4 channels of GTT Infrared Opticom Detection. c. 37 Pin Connector(J1)attached to the printed circuit board for detector rack TS2 designated inputs/outputs d. 20 Pin Connector (J2) attached to the printed circuit board for GTT Infrared Opticom TS2 designated inputs/outputs. e. 6 Pin Connector(J3)attached to the printed circuit board for power TS2 designated inputs/outputs. Ordering Number Logic: Mobotrex,Part Number:ACP14829P002 or approved equivalent CCTO 2201 NEMA TS2 Type-1 Load Bay circuit board per the following and per State of Florida Approved Products List: a. Manufacturer:Transportation Control Systems Inc. b. Description: 1. Printed Circuit Board(PCB)for Traffic Signal Cabinet Loadbay BIU 1. Ordering Number Logic: CCTO 2201 Transportation Control Systems Inc.,PCB for Loadbay BIU 1,TCS 223619 or approved equivalent APL Number:676-034-003 CCTO 2362 CCTV Camera Ethernet Extender components per the following and per State of Florida Approved Products List: a. POE(power over ethernet)for CAT 5e or Cat6 b. 57V 800mA power supply for POE Ordering Number Logic: Veracity USA,Inc.,Part Number:VPSU-57V-800 or approved equivalent CCTO 2374 Camera Ethernet Extender components per the following and per State of Florida Approved Products List: a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6 b. Ethernet Interface: RJ45 c. POE injector d. Power supply included Ordering Number Logic: Veracity USA,Inc.,Outreach Lite,Part Number:VOR-ORL-XT(LITE)or approved equivalent CCTO 2375 Camera Ethernet Extender components per the following and per State of Florida Approved Products List: a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6 b. Ethernet Interface:RJ45 c. POE injector d. Power supply included Ordering Number Logic: Veracity USA,Inc.,Outreach Max,Part Number:VOR-ORM-XT(MAX)or approved equivalent CCTO 2376 Camera Ethernet Extender components per the following and per State of Florida Approved Products List: a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6 b. Ethernet Interface: RJ45 c. POE injector d. Power supply included Ordering Number Logic: Veracity USA,Inc.,Outsource,Part Number:VOR-OSP or approved equivalent 15 fr ) 1 68 6 CCTO 2378 Ethernet Extender,Set for Cate 5e of 6;Veracity#VLS-1N-L 1 set includes: a. (1)long range ethernet 6100-FV-VLSINL-LONGSPAN LITE POE b. (1) 12V DC Power supply 6100-VV-VPSU12VUS-POWER SUPPLY Ordering Number Logic: Veracity USA,Inc.,Outsource,Part Number:VLS-IN-L or approved equivalent CCTO 2927 Reducer Bushing, 1-1/2"NPT x 3/4"NPT,Galvanized Iron per the following: a. Material:Galvanized Iron. b. Reducer 1-1/2"NPT x 3/4"NPT Ordering Number Logic: Pelco Products Inc.,Part Number:SE-0471-GLV or approved equivalent Sign Beacon CCTO 1514 School Zone Flasher, Solar Powered, Single Beacon per the following and per State of Florida Approved Products List: a. Operation:School Zone b. Power Source: Solar/Battery c. Battery System: 12 VDC, 100 Ahr d. Solar System:80 W high-efficiency photovoltaic solar panel. e. Solar Engine Mounting:Top of Pole, 4.0"-4.5"Diameter Round Pole Mount f. Cabinet Finish:Natural Aluminum g. Number of Beacons: Single h. Beacon Mounting: Single i. Type of Beacon:Dialight, 12 VDC, 12 inch,Yellow LED. j. Signal head Material:Aluminum k. Signal Head Finish:Black 1. Visor Type:Tunnel m. Integrated with the following 3rd-party Time Clock: 1. Temple FCU 500-071 (FL only) 2. RTC AP21,AP22,CPR2102,and M2M modem n. Includes Time Clock Kit,No Clock o. Wireless range: 1000 ft(305 m) Ordering Number Logic: Carmanah Technologies Corp.,Model:R829G with single beacon or approved equivalent APL Number: 700-026-014 CCTO 1516 School Zone Flasher,Solar Powered,Dual Beacon per the following and per State of Florida Approved Products List: a. Operation: School Zone b. Power Source: Solar/Battery c. Battery System: 12 VDC, 100 Ahr d. Solar System: 80 W high-efficiency photovoltaic solar panel. e. Solar Engine Mounting:Top of Pole,4.0"-4.5"Diameter Round Pole Mount f. Cabinet Finish:Natural Aluminum g. Number of Beacons:Dual h. Beacon Mounting:Dual-Vertical i. Type of Beacon:Dialight, 12 VDC, 12 inch,Yellow LED. j. Signal head Material:Aluminum k. Signal Head Finish:Black 16 1. Visor Type:Tunnel m. Integrated with the following 3rd-party Time Clock: 1. Temple FCU 500-071 (FL only) 2. RTC AP21,AP22,CPR2102,and M2M modem n. Includes Time Clock Kit,No Clock o. Wireless range: 1000 ft(305 m) Ordering Number Logic: Carmanah Technologies Corp.,Model:R829G with dual vertical beacons or approved equivalent APL Number: 700-026-014 CCTO 1519 Flashing Beacon,Solar Powered,Single Beacon per the following and per State of Florida Approved Products List: a. Operation:24-7 Flashing b. Power Source: Solar/Battery c. Battery System: 12 V 14 Ahr.battery system d. Solar System: 13 W high-efficiency photovoltaic solar panel. e. Solar Engine Mounting: Single—Integrated Engine and Beacon f. Beacon Mounting:4.0"-4.5"Diameter Round Pole Mount g. Type of Beacon: 12 in(305 mm)diameter LED modules,yellow or red h. Signal head Material:Aluminum i. Signal Head Finish:Black j. Visor Type:Tunnel Ordering Number Logic: CCTO 1519 Carmanah Technologies Corp.,Model:R247-E with Yellow beacon or approved equivalent APL Number: 700-026-003 CCTO 1523 Midblock Crosswalk Enhancement Assemblies — Rectangular Rapid Flashing Beacon Assembly (RRFB) per the following and per State of Florida Approved Products List: a. Power Source: Solar/Battery. b. Solar Engine Construction:Weatherproof,gasketed enclosure with vents for ambient air transfer,NEMA 3R rated. c. Solar Panel:30 W high-efficiency photovoltaic solar panel. d. Battery system: 12 V 34 Ahr. e. Solar Engine Finish:Black f. Solar Engine Mounting:4.0"-4.5"Diameter Round Top of Pole Mount. g. Light Bar Configuration:Single or Dual. h. Push button:ADA-compliant,piezo-driven with visual LED and two-tone audible confirmation. i. Push button color:Black j. Wireless range: 1000 ft(305 m). k. Encrypted,wireless radio with 2.4 GHz mesh technology I. Meets or exceeds MUTCD requirements,including IA-21. m.Flash patterns:RFB1 (WW+S),RFB2(WSDOT),0.5 sec.alternating(MUTCD),0.5 sec.unison(MUTCD), 0.1 sec.unison,0.25 sec.unison,0.1 sec.x3 quick flashes unison,0.1 sec.x3 quick flashes alternating. Ordering Number Logic: CCTO 1523 Carmanah Technologies Corp., Single Light Bar Configuration, Model Number: R920 or approved equivalent APL Number: 654-001-004 Ordering Number Logic: CCTO 1523a Carmanah Technologies Corp., Dual Light Bar Configuration, Model Number: R920 or approved equivalent APL Number: 654-001-004 CCTO 3160 Electronic Display Sign(EDS)—Electronic Speed Feedback Sign(ESFS)per the following and per State of Florida Approved Products List: 17 16B 6 a. Operation: School Zone Power Source: Solar/Battery b. Display Message LED digits: 15 inches. C. Includes one Dialight 12-inch yellow LED beacon(MUTCD Compliant). Ordering Number Logic: TO 3160:Carmanah Technologies Corp.,Information Display Company,One Dialight 12-inch yellow LED. CCTO 2205 Cellular Programmable Temple Inc. FCU-500-071 Time Switch System per the following and per State of Florida Approved Products List: a. Input Voltage: 16-30V DC, 120V AC. b. Connectivity:Cellular Communications,Ethernet Port(10/100Base-T) c. Optional 5 year Cellular connectivity plan d. Compatible with Glance platform e. GPS enabled for self-locating f. Includes connector and Wiring Harness g. Includes high gain antenna Ordering Number Logic: CCTO 2205 Includes 5 year Cellular connectivity plan.Temple Inc.,Part Number FCU-500-071 or approved equivalent APL Number:678-008-023 CCTO 2106 Type 1 Wired Flasher Cabinet Assembly per the following and per State of Florida Approved Products List: I. Operation:School Zone m.Power Source: Solar/Battery n. Meets NEMA 3R requirements for cabinet enclosure. o. Constructed of 0.125"thick 5052-H32 aluminum. p. Doubled flanged door opening on all four sides. q. Slam Lock System that accepts#2 Corbin keys. r. Tamperproof 14 gauge stainless steel hinge. s. Closed-Cell Neoprene Gasket around the inside edges of the door. t. Louvered vents on the top left and bottom right sidewalls with bug screens. u. Back panel for equipment mounting. v. Mounting option for flat or round surface. w. Conforms to NEC wiring specifications. Ordering Number Logic: CCTO 2106 Temple Inc.,Part Number: TF4001F-FL-DC with Mounting option for flat surface or approved equivalent APL Number: 700-026-018 Pull,Splice and Junction Boxes CCTO 2702 Pull Box(Box)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty c. Rated:20,000 lb. d. Open Bottom e. Inside Dimensions:Width: 13 Inches,Length: 24 Inches,Depth: 12 Inches. 10) Ordering Number Logic: Strongwell Quazite PG1324BA12 or approved equivalent APL Number:635-001-025 18 168 6 CCTO 2704 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. Manufacturer's logo shall be stamped on each pull box cover along with the words"TRAFFIC SIGNALS". Ordering Number Logic: Strongwell Quazite PG1324HA or approved equivalent APL Number:635-001-025 CCTO 6615 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. (2" Thick x 13" W x 24" L) f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY LIGHTING". Ordering Number Logic: Strongwell Quazite PG1324HA or approved equivalent APL Number: 635-001-025 CCTO 6622 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. (1-3/4" Thick x 11" W x 18" L) f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY LIGHTING". Ordering Number Logic: Strongwell Quazite PG1118HA or approved equivalent APL Number: 635-001-025 CCTO 6625 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. (3/4" Thick x 11" W x 18" L) f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY LIGHTING". Ordering Number Logic: Strongwell Quazite PG1118HA or approved equivalent APL Number: 635-001-025 CCTO 2706 Pull Box(Box)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty 19 16B 6 c. Rated:20,000 lb. d. Open Bottom e. Inside Dimensions:Width: 17 Inches,Length: 30 Inches,Depth: 12 Inches. Ordering Number Logic: Strongwell Quazite PG1730BA12 or approved equivalent APL Number:635-001-014 CCTO 2708 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. Manufacturer's logo shall be stamped on each pull box cover along with the words"TRAFFIC SIGNAL". Ordering Number Logic: Strongwell Quazite PG17301-IA or approved equivalent APL Number: 635-001-014 CCTO 2710 Pull Box(Box)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty c. Rated:20,000 lb. d. Open Bottom e. Inside Dimensions: Width:24 Inches,Length:36 Inches,Depth:24 Inches. Ordering Number Logic: Strongwell Quazite PG2436BA24 or approved equivalent APL Number: 635-001-012 CCTO 2712 Pull Box(Cover)per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Cover shall fit the above Pull Box e. Manufacturer's logo shall be stamped on each pull box cover along with the words "TO COMMUNICATIONS". Ordering Number Logic: Strongwell Quazite PG2436HA or approved equivalent APL Number: 63 5-001-012 CCTO 2714 Pull Box per the following and per State of Florida Approved Products List: a. Material:Polymer Concrete b. Heavy Duty w/2 Bolts c. Rated:20,000 lb. d. Inside Dimensions:Width:24 Inches,Length:36 Inches,Depth: 18 Inches. Ordering Number Logic: Strongwell Quazite PB24360612B18 or approved equivalent APL Number: 635-001-012 CCTO 3114 Strand Vice,3/8 inch,for Utility Grade Steel Strand per the following: a. Primary Strand Application:3/8 inch b. Wire Range=.325-.392 c. Bail Type:A(Standard) 20 168 6 11) Ordering Number Logic: MacLean Power Systems,Part#5202 or approved equivalent CCTO 3120 Cable,3/8 inch Utilities Grade Steel Strand per the following: a. Required minimum breaking strength: 11,500 pounds. b. Type of coating:Class A zinc coating in accordance with ASTM A475. c. Stranding(Number X Diameter):7 X 0.120 d. 1000 ft.spool length Ordering Number Logic: 3/8 inch Utility Grade Steel Strand IMSA Traffic Signal Cable CCTO 1702 Traffic Signal Cable,IMSA 50-2,Stranded,AWG 14,2 Conductors per the following: a. IMSA Specification:50-2 b. Cable Length: 5000 ft. Spool c. Conductor Type:Stranded(19) d. Color Code:per Specification e. Conductor Insulation:Polyethylene f. Cable Jacket: Black Polyethylene g. Aluminum/Mylar Tape 12) Ordering Number Logic: IMSA 50-2 CCTO 2602 Traffic Signal Cable,IMSA 19-1,Stranded,AWG 14 per the following: a. IMSA Specification: 19-1 b. Cable Length:2000 ft. Spool c. Conductor Type:Stranded(7) d. Color Code:per Specification e. Conductor Insulation:Polyethylene f. Cable Jacket: Black PVC Ordering Number Logic: CCTO 2602 5 Conductor Traffic Signal Cable Ordering Number Logic: CCTO 2602a 7 Conductor Traffic Signal Cable Ordering Number Logic: CCTO 2602b 9 Conductor Traffic Signal Cable Ordering Number Logic: CCTO 2602c 12 Conductor Traffic Signal Cable Ordering Number Logic: CCTO 2602e 16 Conductor Traffic Signal Cable Electrical Power Service Hardware CCTO 2804 Load Center, 100A,Fixed-Factory installed main lugs, 120/240VAC per the following: a. Short Circuit Current Rating: 10 kA b. Maximum Single Pole Circuits: 12 c. Maximum Tandem Circuit Breakers:6 d. Spaces:6 21 • 168 6 e. Ampere Rating: 100A f. Voltage Rating: 120/240VAC g. Grounding Bar Included h. Cover Type: Surface i. Enclosure Type:Outdoor/Rainproof j. Enclosure Rating:NEMA 3R k. UL Listed Ordering Number Logic: Square D Cat.No.QO6I2LI00TRB or approved equivalent Cameras CCTO 2390 CCTV Axis PTZ Camera per the following and per State of Florida Approved Products List: a.Include Power Supply b.5-year Warranty 06075-E. Ordering Number Logic: Model:AXIS-Q6075-E;Manufacturing part#01752-004 or approved equivalent CCTO 2391 XIS-Q6075-E Camera Pendant Mount Kit for TO 2390- Axis Camera and per State of Florida Approved Products List: Ordering Number Logic: Model: Part#T94A01 D or approved equivalent CCTO 2395 CCTV Connector per the following and per State of Florida Approved Products List: RJ45 push pull plug connector kit 5700-371 Ordering Logic Number:TO 2395 Model:6100-AXIS-RJ45-OUT:or approved equivalent CCTO 2393 CCTV Axis Camera power supply per the following and per State of Florida Approved Products List: a. Include Power Supply Ordering Number Logic: Model: 5900-331-01 or approved equivalent CCTO 2908c AXIS-Sky Bracket Mount Cable per State of Florida Approved Products List: Ordering Logic Number:TO 2908c Cable-120";Model 6100-AXIS CCTO 2396 CCTV Camera License per the following and per State of Florida Approved Products List: Core device licenses(0879-010)for Axis devices and 2N intercoms Ordering Logic Number: for Axis devices and 2N intercoms CCTO 2397 CCTV Camera License per the following and per State of Florida Approved Products List: Universal device licenses(0879-020) Ordering Logic Number: • CCTO 1791 Fiber Patch Yellow Cord/Cables,LC/ST/3M OS2,Duplex,w/twist connector for Axis Camera; Model: LCSTDUPSM-3M Ordering Logic Number:TO 1791 22 i6B6 CCTO 1792 Fiber Patch Yellow Cord/Cables,LC/SC/3M 0S2,Duplex,w/Clip connector for Axis Camera;Model: LCSCDUPSM-3M Ordering Logic Number:TO 1792 Switches CCTO 3300 Network Devices,per the following and per State of Florida Approved Products List:Rugged,Modular Base,8 Copper plus 2 Fiber Ports,Cisco IE3300-8T2S-E 10 Port Ethernet Switch Ordering Number Logic: Cisco IE3300-8T2S-E,or approved equivalent CCTO 3301 Network Devices,per the following and per State of Florida Approved Products List:Proline Cisco GLC-LX-SM- RGD,Fiber SSP Ordering Number Logic: TO 3301,or approved equivalent CCTO 3302 Network Devices,per the following and per State of Florida Approved Products List:Rugged,8 copper,Cisco IEM 3300-8T 8 Port Ethernet Expansion Ordering Number Logic: Cisco IEM 3300-8T,or approved equivalent CCTO 3303 Network Devices,per the following and per State of Florida Approved Products List: 50 Watts. 100-240VAC, Cisco PWR-IE50W-AC Power Supply Ordering Number Logic: Cisco PWR-IE50W-AC,or approved equivalent CCTO 3304 Network Devices,per the following and per State of Florida Approved Products List:Cisco Optical Transceiver SMF, 1550nm,80km,LC,DOM, IOG,Cisco SFP-10G-ZR-S SFP Ordering Number Logic: Cisco SFP-IOG-ZR-S,or approved equivalent CCTO 1759 Battery Meter per the following and per State of Florida Approved Products List:Tycon system TP-Battmeter-24 12V/24V Battery Meter Ordering Number Logic:TO 1759 Tycon system TP-Battmeter-24 CCTO 2251 Network Devices-Wireless WIFI Router Ordering Number Logic:TO 2251:Teltonika,Model Number:RUT240 or approved equivalent 23 1686 Exhibit B Fee Schedule following this page (pages through 20) Page 16 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1] 16B 6 INVITATION TO BID(ITB)#24-8208 "TRAFFIC SIGNAL COMPONENTS&HARDWARE" EXHIBIT B—FEE SCHEDULE PRIMARY AWARDED SECONDARY AWARDED NOT AWARDED TRANSPORTATION SOLUTIONS& LIGHTING,INC. Line Equivalent with APL Item TO Description QTY Unit Price (if applicable) and Number Number part number Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head:SOLID Three(3) Section Horizontal configuration per MUTCD 1 TO 1502 Part 4,Figure (B—Typical Arrangements) 1 $ 437.50 Ordering Number Logic: TO 1502:Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head:ARROW Three(3)Section 2 TO 1506 Horizontal configuration per MUTCD Part 4, 1 $ 457.50 Figure 4D-10(B—Typical Arrangements) Ordering Number Logic: TO 1506: Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head: Four(4)Section Horizontal configuration per MUTCD Part 4, 3 TO 1509 Figure 4D-12(B—Typical Arrangements) 1 $ 567.00 Ordering Number Logic: TO 1509:Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent 1 1 68 6 Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head:Five(5)Section Horizontal 4 TO 1510 configuration per MUTCD Part 4,Figure 4D- 1 719,00 11 (B—Typical Arrangements)Ordering Number Logic: TO 1510:Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head:Four(4)Section Vertical 5 TO 1511 configuration per MUTCD Part 4,Figure 4D- I $ 594.00 12(B—Typical Arrangements)Ordering Number Logic: TO 1511:Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent Signal,Vehicle Traffic Control per the Equivalent not approved following and per State of Florida Approved Products List: Signal Head:Five(5)Section Vertical Cluster 6 TO 1512 configuration per MUTCD Part 4,Figure 4D- 1 879,00 11 (B—Typical Arrangements) Ordering Number Logic: TO 1512:Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida Approved Products List:Optical Unit:Light 7 TO Emitting Diode(LED) 12-inch Diameter,Solid 1 $ 51.75 1513-R Red. Ordering Number Logic: TO 1513-R: 12"Dialight LED Red Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida Approved Products List:Optical Unit:Light 8 TO Emitting Diode(LED) 12-inch Diameter,Solid I $ 51.75 1513-Y Yellow. Ordering Number Logic: TO 1513-Y: 12"Dialight LED Yellow Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida Approved Products List:Optical Unit:Light 9 TO Emitting Diode(LED) 12-inch Diameter,Solid s 51.75 1513-G Green. Ordering Number Logic: TO 1513-G: 12"Dialight LED Green Signal or approved equivalent 2 16B6 Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida TO Approved Products List:Optical Unit:Light 10 1513- Emitting Diode(LED) 12-inch Diameter, 1 $ 57.50 RA Arrow Red. Ordering Number Logic: TO 1513-RA: 12"Dialight LED Arrow Red Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida TO Approved Products List:Optical Unit:Light 11 1513- Emitting Diode(LED) 12-inch Diameter, 1 $ 57.50 YA Arrow Yellow. Ordering Number Logic: TO 1513-YA 12"Dialight LED Arrow Yellow Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following and per State of Florida TO Approved Products List:Optical Unit:Light 12 1513- Emitting Diode(LED) 12-inch Diameter, 1 $ 57.50 GA Arrow Green. Ordering Number Logic: TO 1513-GA 12"Dialight LED Arrow Green Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following: TO Optical Unit:Light Emitting Diode(LED) 12- 13 1513- inch Diameter,U-Turn Red.Ordering Number 1 $ 35.00 RU Logic: TO 1513-RU: 12"Dialight LED U-Turn Red Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following: TO Optical Unit:Light Emitting Diode(LED) 12- 14 1513- inch Diameter,U-Turn Yellow.Ordering 1 $ 35.00 YU Number Logic: TO 1513-YU: 12"Dialight LED U-Turn Yellow Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts Equivalent not approved per the following: TO Optical Unit:Light Emitting Diode(LED) 12- 15 1513- inch Diameter,U-Turn Green.Ordering 1 $ 35.00 GU Number Logic: TO 1513-GU: 12"Dialight LED U-Turn Green Signal or approved equivalent Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List:Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid $ 55.00 16 TO Red and Solid Yellow. 1 1513-RF Operating Voltage: 10-30V DC optical unit. Primary Award Ordering Number Logic: TO 1513-RF: 12"Dialight 10-30 V DC LED Red Signal,Part Number:433-1210-005XL or approved equivalent 3 I6B6 Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List:Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid 55.00 17 TO Red and Solid Yellow. 1 1513-YF Operating Voltage: 10-30V DC optical unit. Primary Award Ordering Number Logic: TO 1513-YF: 12"Dialight 10-30 V DC LED Yellow Signal,Part Number:433-3230-905XL or approved equivalent Signal Visor,Vehicle Traffic Control per the following and per State of Florida Approved Products List: Signal Head 12"Tunnel Visor $ 21.00 18 TO 1532 Ordering Number Logic: 1 TO 1532:Mobotrex housing Visor or Primary Award approved equivalent Back plates,Horizontal 1-Section Signal Head Equivalent not approved per the following and per State of Florida Approved Products List:Louvered with 2" 19 TO 3002 Reflective 3M Tape 1 $ 42.00 Fits Signal Head Brand:Eagle Signal Ordering Number Logic: TO 3002:Transportation Control Systems Part No.BP-5001B-F or approved equivalent Back plates,Horizontal 2-Section Signal Head Equivalent not approved per the following and per State of Florida Approved Products List:Louvered with 2" 20 TO 3004 Reflective 3M Tape 1 $ 58.00 Fits Signal Head Brand:Eagle Signal Ordering Number Logic: TO 3004:Transportation Control Systems Part No.BP-5002B-F or approved equivalent Back plates,Horizontal 3-Section Signal Head Equivalent not approved per the following and per State of Florida Approved Products List:Louvered with 2" 21 TO 3008 Reflective 3M Tape 1 $ 75.00 Fits Signal Head Brand:Eagle Signal Ordering Number Logic: TO 3008:Transportation Control Systems Part No.BP-5003B-F or aproved equivalent Back plates,Horizontal 4-Section Signal Head Equivalent not approved per the following and per State of Florida Approved Products List:Louvered with 2" 22 TO 3010 Reflective 3M Tape 1 5 114.00 Fits Signal Head Brand:Eagle Signal Ordering Number Logic: TO 3010:Transportation Control Systems Part No.BP-5004B-F or approved equivalent Back plates,Horizontal 5-Section Signal Head Equivalent not approved per the following and per State of Florida Approved Products List: Louvered with 2" 23 TO 3012 Reflective 3M Tape 1 132.00 Fits Signal Head Brand:Eagle Signal Ordering Number Logic: TO 3012:Transportation Control Systems Part No.BP-5005B-F or approved equivalent 4 � 68 Back plates,Vertical Cluster 5-Section Signal Equivalent not approved Head per the following and per State of Florida Approved Products List:Louvered with 2" Reflective 3M Tape 24 TO 3014 Fits Signal Head Brand:Eagle Signal Cluster 1 $ 132.00 Mast Arm Mount Ordering Number Logic: TO 3014:Transportation Control Systems Part No.BP-5007B-F or approved equivalent Back plates,Cluster 5-Section Signal Head per Equivalent not approved the following and per State of Florida Approved Products List:Louvered with 2" Reflective 3M Tape 25 TO 3016 Fits Signal Head Brand:Eagle Signal Cluster 1 $ 204.00 Span Wire Mount Ordering Number Logic: TO 3016:Transportation Control Systems Part No.BP-5021B-F or approved equivalent Signal,Pedestrian Traffic Control per the following and per State of Florida Approved Products List:Housing: 16"X 18" Symbol:Full Hand&Full Person with egg $ 240.00 26 TO 1540 crate type visor Ordering Number Logic: 1 TO 1540:Mobotrex housing Model Primary Award SG7SZ20C3FFF10-21 or approved equivalent &Dialight Corporation,Model 430-6479- 805XF or approved equivalent Signal,Pedestrian Traffic Control Module per the following and per State of Florida Approved Products List:Optical Unit:LED $ 110.00 27 TO 1542 Single module 1 Symbol:Full Hand&Full Person.Ordering Primary Award Number Logic:TO 1542:Dialight Corporation,Model 430-6479-805XF or approved equivalent Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: Mast Arm Signal Hanger $ 145.00 28 TO Number of Signal Head Sections:3 Cable 1 2922g Length: 120 inches Primary Award Paint No Color Ordering Number Logic:TO 2922g Pelco Products,Inc.,Model Number:SP-1006-FL-3- 120-PNC or approved equivalent Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: Mast Arm Signal Hanger $ 148.00 29 TO Number of Signal Head Sections:4 Cable 1 2922h Length: 120 inches Primary Award Paint No Color Ordering Number Logic:TO#2922h:Pelco Products,Inc.,Model Number:SP-1006-FL-4- 120-PNC or approved equivalent 5 16B 6 Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: Mast Arm Signal Hanger 151.00 30 TO Number of Signal Head Sections:5 Cable 1 2922i Length: 120 inches Primary Award Paint No Color Ordering Number Logic:TO 2922i:Pelco Products,Inc.,Model Number:SP-1006-FL-5- 120-PNC or approved equivalent Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products List: $ 91.50 31 TO Mast Arm Signal Hanger Cable Length: 120 1 2908a inches Paint No Color Primary Award Ordering Number Logic:TO 2908a:Pelco Products,Inc.Model Number:SP-1079-FL- 120-PNC or approved equivalent Mast arm Astro-Brac Steller Articulating clamp Mount Assembly per the following and per State of Florida Approved Products List: Bracket Articulated Mounting.Cable Length: 32 2928a 96 inches 1 $ 175.00 Paint No Color Ordering Number Logic: TO 2928a Pelco Products,Inc.,Part No.SP- 1118-FL-96-PNC or approved equivalent Mast arm Astro-Brac Steller Articulating clamp Mount Assembly per the following and per State of Florida Approved Products List: Bracket Articulated Mounting.Cable Length: 33 2928b 96 inches 1 $ 178.00 Paint No Color Ordering Number Logic: TO 2928a Pelco Products,Inc.,Part No.SP- 1118-FL-120-PNC or approved equivalent Hanger Assembly,Tri-Stud per the following and per State of Florida Approved Products List:Cast Aluminum Upper and Lower Hanger $ 116.00 34 TO 2926 Paint No Color 1 Ordering Number Logic: Primary Award TO 2926:Pelco Products,Inc.,Part No.SP- 1050-FL-PNC or approved equivalent Disconnect for Single Door,per the following and per State of Florida Approved Products List:Color:Cat Alum w/SS Hardware Non- $ 140.00 35 TO 2924 Thread top&Tri-Stud 1 Ordering Number Logic:TO 2924:Pelco Primary Award Products Inc.,Part No.:SE-1087-FL-2 or approved equivalent Bracket Assembly,Tri-Stud Upper Arm per the following and per State of Florida Approved Products List: Direction: 2-Way $ 60.50 36 TO 2940 Color:Flat Black Ordering Number Logic: 1 TO 2940:Pelco Products,Inc.,Part No.SP- Primary Award 1026-FL-P34 or approved equivalent 6 1 68 6 Bracket Assembly,Single Stud Lower Arm per the following and per State of Florida Approved Products List.Direction: 2-Way 37 TO 2942 Color: Flat Black Ordering Number Logic: 1 $ 60.50 TO 2942:Pelco Products,Inc.Part No.SP- 1027-FL-P34 or approved equivalent Pedestrian Bracket Assemblies,Aluminum side of pole,Tri-Stud per the following and per State of Florida Approved Products List: 39.00 38 TO 1602 Tri-Stud Upper Arm Assembly Color:Flat 1 Black Primary Award Ordering Number Logic: TO 1602:Pelco Products Inc.Part Number: SP-1011-FL-P34 or approved equivalent Pedestrian Bracket Assemblies,Aluminum side of pole,Tri-Stud per the following and per State of Florida Approved Products List: $ 39.00 39 TO 1604 Tri-Stud Lower Arm Assembly Color:Flat 1 Black Primary Award Ordering Number Logic: TO 1604:Pelco Products Inc.Part Number: SP-1012-FL-P34 or approved equivalent Closure Assembly,Vehicle Traffic Control Signal per the following and per State of Florida Approved Products List: Signal head $ 11.00 40 TO 1518 closure kit 1 Ordering Number Logic: Secondary Award TO 1518:Pelco Products,Inc. SE-3054-P02 or approved equivalent Post Top Adapter(Slip Fitter),Pedestrian Traffic Control Signal per the following and per State of Florida Approved Products List $ 50.00 41 TO 2952 Aluminum Tri-Stud Adapter for use with 4-1/2 1 inch OD Aluminum Pole Paint No Color Primary Award Ordering Number Logic: TO 2952:Pelco Products,Inc.Part No.,EC- 3004-T-PNC or approved equivalent Pole,Spun Aluminum,Schedule 40,per the following and per State of Florida Approved Products List: Size:4.5 inch OD $ 230.00 42 TO Length:7'Paint No Color 2954c Ordering Number Logic: Primary Award TO 2954c:Pelco Products,Inc.Part No.,PB- 5100-7-PNC or approved equivalent Sign Mountings Anchor bolt per the following N/A and per State of Florida Approved Products List:Anchor Bolt Sets $ 61.00 43 TO 2959 Exterior:Galvanized Includes 4 each:Bolts, Washers and Nuts Ordering Number Logic: Primary Award TO 2959:Pelco Products Inc.,Part Number: PB-5543-GL 7 168 6 Pedestal Base,Alum with Alum Door, 13 Equivalent not approved 5/8"x13 5/8"x15",Threaded for 4.5"OD Alum Pole per State of Florida Approved Products 44 TO 2960 List: 1 $ 305.00 Ordering Number Logic: TO 2960:Pelco Model SP-1116-FL-GL-PNC or approved equivalent Collar,Reinforcing for Square Pedestal Base, 4.5"OD Alum Pole,Stainless Steel Fasteners per State of Florida Approved Products List: 45 TO 2962 Ordering Number Logic: 1 $ 125.00 TO 2962:Pelco Model PB-5325 or approved equivalent Sign Hanger Assembly,Mast Arm,Free Equivalent not approved Swinging,Mini Brac Mount,84"Cable, Stainless Steel Hardware per State of Florida 46 TO Approved Products List: 1 $ 177.00 2981b Ordering Number Logic: Pelco Products Inc.Part No.SP-1072-FL-84- PNC or approved equivalent;Material: Aluminum,length: 84 inches Traffic Signal Hardware,Components,Pipe Fittings, 1 1/2"Grommet,Neoprene w/ 47 TO 2984 Diaphragm for Disconnect Cable Openings 1 $ 10.00 Pelco Products Inc.Part No.SE-0449-PNC or approved equivalent; Traffic Signal Hardware,Components,Pipe Fittings per the following and per State of Florida Approved Products List: 48 TO 2986 Double Serrated Lock ring,Aluminum 1 $ 9.00 Ordering Number Logic: TO 2986:Pelco Products Inc.Part No. SE- 0451-PNC or approved equivalent Hardware,Components,Extension(Extender), Alum,72" Ordering Number Logic: 49 TO 2994 TO 2994:Pelco Products Inc.,Part Number: 1 $ 46.00 SE-0507-72 or approved equivalent Pole Cap,Acorn Type,Alum,4 1/2"OD Pole, Stainless Steel Fasteners, No Paint Ordering Number Logic: $ 20.00 50 TO 3030 TO 3030:Pelco Model:PB-5401 or approved 1 equivalent Primary Award NOT AWARDED Utility Pole Hardware,7/8" N/A 36,,009-Ib -Rod Diameter,Rod Length 120"(10ft),End Fittings Clovis w, no„ 5-1- TO 3126 Clovis Clevis 2 Roller per State of Florida + Approved Products List • G836120CC2 8 16 8 f, Pushbutton,Pedestrian Detector(Momentary Equivalent not approved LED Model)per the following and per State of Florida Approved Products List: 52 TO 1806 Ordering Number Logic: Ordering 1 $ 160.00 Number Logic: TO 1806:Polara Bulldog III BDL3-B or approved equivalent Pushbutton,Pedestrian Detector,Aluminum Equivalent not approved Push Button Cup,per the following and per State of Florida Approved Products List: 53 TO 1808 Aluminum cup for mounting the BullDog 1 $ 40.00 Pedestrian Detector.Color:Black Ordering Number Logic: TO 1808:Polara Aluminum Push Button Cup APBC2-B or approved equivalent Pushbutton,Pedestrian Detector, Audible/Tactil a Pedestrian Detector with Pedestrian Station Monitor,per the following and per State of Florida Approved Products List: Push Button:ADA Compliant,raised tactile 54 TO 1812 arrow on button,solid state switch rated to 20 1 $ million actuations minimum. Color:Black Ordering Number Logic: TO 1812:Polara 2 Wire Navigator Push Button Station EN23TN1-B or approved equivalent Detector,Dual Channel Rack Mount Loop per the following and per State of Florida Approved Products List: 55 TO 1704 Ordering Number Logic:TO 1704:Eberle 1 $ Design Inc.,Part No.LMD622 sesries or approved equivalent Controller,Traffic NEMA TS2,Type 2 per the Equivalent not approved following and per State of Florida Approved Products List:Q-Free XN-2 NEMA TS2,Type 56 TO 2010 2 1 $ 4,362.00 Ordering Number Logic:TO 2010: Q-Free XN-2 or approved equivalent Cabinet,Traffic Signal Controller Assembly Equivalent not approved per the following and per State of Florida Approved Products List:NEMA Standard TS2 Type 1 size Type 6 with: One(I)detector rack with one(1)BIU,8 Two Channel Detector Cards,and one(1)GTT 57 TO 2102 Opticom Phase Selector Card 1 $ 15,745.00 One(1)detector rack with one(1)BIU,8 Two Channel Detector Cards; One(1)cabinet power supply,TS-2;Sixteen(16)NEMA load switches One(1)NEMA flasher;Six (1)NEMA flash transfer relays Ordering Number Logic:TO 2102 9 168 6 Cabinet,Traffic Signal Controller Assembly Power Connector Adapter Cable from TS2, Type I to TS2,Type 2 Traffic Controller. 58 TO 2105 Ordering Number Logic: 1 $ Temple,Inc Part Number:ABW 12027P001 or approved Equivalent APL Number:676-034-001 Cabinet Power Supply,TS-2 per the following and per State of Florida Approved Products List:Ordering Number Logic: 59 TO TO 2206A:Eberle Design Inc.,Part No.EDI- 1 $ 595.00 2206a PS250 or approved equivalent SmartMonitor Program Card,Malfunction Management Unit(MMU2)per the following and per State of Florida Approved Products $ 250.00 60 TO 2223 List:Compatible with MMU2-16LE(ip)s 1 Ordering Number Logic:TO 2223:Eberle Primary Award Design Inc.,MMU2-16LE(ip)SmartMonitor Program Card or approved equivalent NEMA Load Switch per the following and per State of Florida Approved Products List: Ordering Number Logic: $ 42.00 61 TO 2224 TO 2224:Power Distribution&Control,Inc., 1 Part No.SSS-86-3 or approved equivalent Secondary Award NEMA Flasher Load Switch Type 3 per the following and per State of Florida Approved Products List:Ordering Number Logic: 62 TO 2226 TO 2226:EDI 810-Power Distribution& 1 $ Control,Inc.,Part No.SSF-86-3 or approved equivalent Flasher Relay Al DC per the following and per State of Florida Approved Products List: Ordering Number Logic: 63 TO 2227 TO 2227:AI 900-010 or approved equivalent 1 $ Bus Interface Unit(BIU)per the following and per State of Florida Approved Products List: Ordering Number Logic: $ 265.00 64 TO 2228 TO 2228:Eberle Design Inc.,Model:BIU-700 or approved equivalent Primary Award 10 1686 4 11/16 inch Square Axial Fan per the following:Fan Voltage: 115 VAC Ordering Number Logic: $ 30.00 65 TO 2110 TO 2110:Dayton Part Number 2RTK6 or 1 approved equivalent Secondary Award Low Voltage Surge Protector,Isolated Pedestrian Circuit Protector per the following and per State of Florida Approved Products List: Peak Surge Current: 10 kA(8 x 20 µs)Voltage $ 190.00 66 TO 2112 Clamp:30 volts;dual pair(4 wire) 1 Ordering Number Logic: Secondary Award CCTO 2112 Asco Power Technologies,Surge Protector,Model: 175D030S10KLPCNO (Edco PC642C-030)or approved equivalent APL Number: 676-004-010 Standard Socket Card Edge Terminal Connector,Plug-in style socket for Surge suppressors/per the following and per State of Florida Approved Products List: Peak Surge Current: 10 kA(8 x 20 µs); $ 30.00 67 21O 12a Voltage Clamp:30 volts; Ordering 1 Number Logic: Secondary Award CCTO 2112a Asco Power Technologies,Surge Protector,Model:(EDCO PCB1B-WKEY)or approved equivalent APL Number:676-004-010 10 Circuit SDLC Hub per the following and per State of Florida Approved Products List: Compatible with NEMA TS2-Type 1 controller Assembly;Number of SDLC 68 TO 2113 communication ports: 10; 1 $ Ordering Number Logic: Transportation Control Systems Inc.,TS2 Traffic Signal Cabinet, 10 circuit,SDLC Hub or approved equivalent APL Number:676- 034-003 Flash Transfer Relay per the following and per State of Florida Approved Products List:Pole Configuration:DPDT 69 TO 2302 Coil Input Voltage: 110/120 VAC 50/60 Hz $ Contact Load Rating:20 Amps at 120 VAC Ordering Number Logic: TO 2302:Deltrol Controls,Model:295 or approved equivalent Filter,Traffic Cabinet AC Power Line per the following and per State of Florida Approved Products List: 70 TO 21 18 120VAC,60A,50/60Hz;UL 1283 Compliant 1 $ Ordering Number Logic:Asco Power Technologies,Model:250120NF060AN3N0 (Edco INXT120NL000-1)or approved equivalent 11 168 6 NEMA TS2 Type-1 Load Bay circuit L-board per the following and per State of Florida Approved Products List:Manufacturer:Eagle 71 TO 2202 Ordering Number Logic: 1 $ TO 2202:Mobotrex,Part Number: ACP11957P001 or approved equivalent Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List: Housing and Circuitry for one(1)BIU and 8 Two Channel Detector Cards;37 Pin Connector attached to the printed circuit board for designated inputs/outputs 72 TO 2208 Dimensions: 14.6"W x 5.4"H x 7.5"D I $ Ordering Number Logic: Mobotrex,Part Number: CDR100 or approved equivalent APL Number:676-028-001 Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List: Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List: Housing and Circuitry for one(1)BIU and 4 Two Channel Detector Cards.;37 Pin 73 TO 2210 Connector attached to the printed circuit board I for designated inputs/outputs Dimensions:9.8"W x 5.9"H x 7.1"D Ordering Number Logic: Mobotrex,Part Number:CDR101 or approved equivalent APL Number:676-028-001 Rack TS2,Eagle Cabinet Detector per the following and per State of Florida Approved Products List: Housing and Circuitry for one(1)BIU,8 Two 74 TO 2212 Channel Detector Cards,and one(1)GTT 1 $ Opticom Phase Selector Card. Ordering Number Logic: TO 2212:Mobotrex(Eagle),Part Number: AAD12047P001 or approved equivalent Rack TS2,TCS Cabinet Detector per the following and per State of Florida Approved Products List: Housing and Circuitry for one(1)BIU,8 Two 75 TO 2214 Channel Detector Cards,and one(1)GTT 1 g Opticom Phase Selector Card. Ordering Number Logic: TO 2214:TCS Part Number TCS CRBIU8-5; TCS-413: or approved equivalent 12 168 6 Inductive Loop Panel,TS2,Cabinet Detector per the following and per State of Florida Approved Products List: PCB for 16 channels 76 TO 2111 (1-16)of inductive loop detection. 1 $ PCB for 4 channels of GTT Infrared Opticom Detection.Ordering Number Logic:TO 2111: Mobotrex,Part Number:ACP14829P002 or approved equivalent NEMA TS2 Type-1 Load Bay circuit board per the following and per State of Florida Approved Products List:Manufacturer: Transportation Control Systems Inc. 77 TO 2201 Printed Circuit Board(PCB)for Traffic Signal I Cabinet Loadbay BIU 1.Ordering Number Logic: TO 2201:Transportation Control Systems Inc., PCB for Loadbay BIU 1,or approved equivalent CCTV Camera Ethernet Extender components per the following and per State of Florida Approved Products List:POE(power over 78 TO 2362 ethernet)for CAT 5e or Cat6 1 $ 57V 800mA power supply for POE Ordering Number Logic: TO 2362:Veracity USA,Inc.,Part Number: VPSU-57V-800 or approved equivalent Ethernet Extender,Outreach Lite Ordering Number Logic:TO 2374 24 Ethernet Extender,Outreach Lite per State 79 TO 2374 of Florida Approved Products List:Veracity 1 $ VOR-ORL-XT or approved equivalent Ethernet Extender,Outreach MAX Ordering Number Logic:TO 2375 24 Ethernet Extender,Outreach MAX per 80 TO 2375 State of Florida Approved Products List: 1 $ Veracity VOR-ORM-XT or approved equivalent Ethernet Extender,Camera Ethernet Extender components per the State of Florida Approved Products List: 81 TO 2376 POE(Power over Ethernet)Network injector 1 $ for CAT 5e or Cat6 Veracity USA, Inc.,Outsource,Part Number:VOR-OSP or approved equivalent Ethernet Extender Set;for Cate 5e of 6 Model Veracity#VLS-IN-L or approved equivalent 82 TO 2378 1 set includes: 1 $ (1)long range ethernet 6100-FV-VLSINL- LONGSPAN LITE POE (1) 12V DC Power supply 6100-VV- VPSUI2VUS-POWER SUPPLY 13 1613 6 Reducer Bushing, 1-1/2"NPT x 3/4"NPT, Galvanized Iron per the following:Material: Galvanized Iron. 83 TO 2927 Ordering Number Logic: I S TO 2927:Pelco Products Inc.,Part Number: SE-0471-GLV or approved equivalent School Zone Flasher,Solar Powered,Single Beacon per the following and per State of Florida Approved Products List: Operation:School Zone Power Source: 84 TO 1514 Solar/Battery Number of Beacons:Single I S Beacon Color:Yellow TO 1514:Carmanah Technologies Corp., Model:R829G with single beacon or approved equivalent School Zone Flasher,Solar Powered,Dual Beacon per the following and per State of Florida Approved Products List:Operation: School Zone 85 TO 1516 Power Source: Solar/Battery Number of I S Beacons:Dual Beacon Color:Yellow Ordering Number Logic: TO 1516:Carmanah Technologies Corp., Model:R829G with dual vertical beacons or approved equivalent Flashing Beacon,Solar Powered,Single Beacon per the following and per State of Florida Approved Products List:Operation: 24-7 Flashing Power Source: Solar/Battery Type of Beacon:Single 12 in(305 mm) 86 TO 1519 diameter yellow LED beacon.Beacon 1 $Mounting:4.0"-4.5"Diameter Round Pole Mount Ordering Number Logic: TO 1519:Carmanah Technologies Corp., Model:R247-E with Yellow beacon or approved equivalent Midblock Crosswalk Enhancement Assemblies p Equivalent not approved —Rectangular Rapid Flashing Beacon Assembly(RRFB) per the following and per State of Florida Approved Products List: Power Source: Solar/Battery. 87 TO 1523 Solar Panel:30 W high-efficiency photovoltaic 1 $ 2,476.00 solar panel.Light Bar Configuration:Single. Ordering Number Logic: TO 1523:Carmanah Technologies Corp., Single Light Bar Configuration,Model Number:R920 or approved equivalent 14 1686 Midblock Crosswalk Enhancement Assemblies Equivalent not approved —Rectangular Rapid Flashing Beacon Assembly(RRFB) per the following and per State of Florida Approved Products List: Power Source: Solar/Battery. 88 TO Solar Panel:30 W high-efficiency photovoltaic 1 $ 3,029.00 1523a solar panel.Light Bar Configuration:Dual Light Bars Ordering Number Logic: TO 1523a:Carmanah Technologies Corp., Dual Light Bar Configuration,Model Number: R920 or approved equivalent Electronic Display Sign(EDS)—Electronic Equivalent not approved Speed Feedback Sign(ESFS)per the following and per State of Florida Approved Products List: Operation: School Zone Power Source: Solar/Battery Display Message LED digits: 15 inches. 89 TO 3160 Includes one Dialight 12 inch yellow LED 1 $ 4.435.00 beacon(MUTCD Compliant).Ordering Number Logic: TO 3160:Carmanah Technologies Corp., Information Display Company,One Dialight 12 inch yellow LED beacon,Model Number:SpeedCheck-15-SZ- S-B1 or approved equivalent Cellular Programmable Temple Inc.FCU-500- 071 Time Switch System per the following and per State of Florida Approved Products List: 90 TO 2205 Includes 5 year Cellular connectivity plan 1 $ Ordering Number Logic: TO 2205:Includes 5 year Cellular connectivity plan.Temple Inc.,Part Number FCU-500-071 or approved equivalent Type 1 Wired Flasher Cabinet Assembly per the following and per State of Florida Approved Products List: Operation: School Zone 91 TO 2106 Power Source: Solar/Battery Mounting option 1 $ for flat surface.Ordering Number Logic: TO 2106:Temple Inc., Part Number: TF400IF-FL-DC with Mounting option for flat surface or approved equivalent NOT AWARDED null Box(Box), r the Products List:Heavy Duty,Rated:20,000 lb. 92 TO 2702 Inside Dimensions:Width: 13 Inches,Length: } S 21 Inches,Depth: 12 Inches.Model: PG1321BA12 Signal Ordering Number Logic: TO 2702 or approved equivalent NOT AWARDED Pull Box(Cover)per the following an d p r State of Florida Approved Products List: I Leavy Duty w/2 Bolts,Rated:20,000 lb. 93 TO 2704 1- $ Ordering Logic:TO 2704 M f turer' 1 sh lI be t� 4 o e4 rmmcrraccurc� �-nib'o arcisn-ocScmi�pc ......».... "TRAFFIC SIGNAL 15 1686 NOT AWARDED Heavy Duty w/2 Bolts, Rated:20,000 lb.(2"Thick x 13" W x 24"L) CCTO Manufacturer's logo shall be stamped on each 6615 pull box cover along with the words 4- "ROADWAY LIGHTING".Ordering Logic: CCTO 6615 NOT AWARDED Heavy Duty w/2 Bolts, Rated:20,000 lb.(I 3/1"Thick x 11"W x 18" 95 C6H 0 Manufacturer's logo shall be stamped on each -1- S "ROADWAY LIGHTING".Ordering Logic: CCTO 6622 NOT AWARDED Heavy Duty w/2 Bolts, CCTO Rated:20,000 lb.(3/4"Thick x 11"W x 18"L) 96 Manufacturer's logo shall be stumped a ch + D 6625 pull box cover along with the words "ROADWAY LIGHTING". NOT AWARDED Pull Box(Box)per the 1- following and per State of Florida Approved 97 TO 2706 Model:PG1730BA12 Inside Dimensions: S Width: 17 Inches,Length:30 Inches,Depth: 12 Inches. Ordering Logic TO 2706 NOT AWARDED Heavy Duty w/2 Bolts, Rated:20,000 lb.(2"Thick x 17"W x 30"L) 9-8 TO 2708 Manufacturer's logo shall be stamped on each + S "TRAFFIC SIGNAL".Ordering Logic TO 2708 NOT AWARDED Pull Box x)por the Products List: Material:Polymer Concrete;Heavy Duty; Rated:20,000 lb.;Open Bottom 9-9 TO 2710 Inside Dimensions:Width:24 Inches,Length: 4- S 36 Inches,Depth:24 Inches. Ordering Number Logic: APL Number:635 001 012 NOT AWARDED Pull Box(Cover)per the Products Liflt: Material: Polymer Concrete;Heavy Duty w/2 Bolts; Rated:20,000 lb.Heavy Duty w/2 Bolts, Rated:20,000 lb.;Fits Pull Box 24 Inches, BOA TO 2712 }Length:36 Inches,Depth: 21 Inches $ Manufacturer's lege shall be stumped e a pull box cover along with the words"TO COMMUNICATIONS".Strongwell Quazitc PG2136HA or approved equivalent;APL Number:635 001 012 16 1686 NOT AWARDED Pull Box(Cover)per the following and per State of Florida Approved Products List: Material:Polymer Concrete;Heavy Duty w/2 101 TO 2711 Bolts; Rated:20,000 lb.Heavy Duty w/2 Bolts, 4- $ Rated:20,000 lb.21X36X 18 Manufacturer's loge shall be stampede ch "TRAFFIC SIGNAL".Ordering Logic 2711 Utility Pole Hardware per the following: 1 7/8"Fiberglass Insulator Minimum Strength (lb)-36,000 $ 55.00 102 TO 3114 7/8"Rod Diameter,Rod Length 120"(loft), End Fittings-Clevis w/Roller-Clevis-Clevis-2 Primary Award Roller Ordering Number Logic:TO 3114 NOT AWARDED Cable,3/8 inch Utilities NIA Grade Steel Strand per the following: 1-03 TO-3 20 Required minimum breaking strength: 11,500 4- $ pounds. 1000 ft spool length Ordering Logic TO 3120 Traffic Signal Cable,IMSA 50-2,Stranded, N/A AWG 14,2 Conductors per the following: $ 2,800.00 104 TO 1702 IMSA Specification: 50-2 Cable Length:5000 1 ft Spool Ordering Logic TO Primary Award 1702 5 Conductor:Traffic Signal Cable, IMSA 19- N/A 1,Stranded,AWG 14 per the following:IMSA $ 1,825.00 105 TO 2602 Specification: 19-1 1 Cable Length:2000 ft.Spool Primary Award Orderding Logic:TO 2602 7 Conductor:Traffic Signal Cable, 1MSA 19- N/A 1,Stranded,AWG 14 per the following:IMSA $ 2,895.00 106 1O Specification: 19-1 1 2602a Cable Length:2000 ft.Spool Primary Award Orderding Logic:TO 2602a 9 Conductor:Traffic Signal Cable, IMSA 19- 1 N/A 1,Stranded,AWG 14 per the following:IMSA $ 5,265.00 107 TO Specification: 19-1 2602b Cable Length:2000 ft.Spool Primary Award Orderding Logic:TO 2602b 12 Conductor:Traffic Signal Cable,IMSA 19- 1 N/A 1,Stranded,AWG 14 per the following:IMSA $ 5,296.00 108 2602c Specification: 19-1 Cable Length:2000 ft.Spool Primary Award Orderding Logic:TO 2602c 16 Conductor:Traffic Signal Cable,IMSA 19- 1 N/A 1,Stranded,AWG 14 per the following:IMSA $ 6.450.00 109 TO Specification: 19-1 2602e Cable Length:2000 ft.Spool Primary Award Orderding Logic:TO 2602e 17 1686 NOT AWARDED Load Center, 100A,Fixed Factory installed main lugs, 120/210VAC per 1-18 TO 2804 Ordering Logic: TO 2804 Ampere Rating: I00A Voltage Rating: 120/24 OV AC CCTV Camera per the following and per State of Florida Approved Products List: PTZ Camera, 1080p,40x optical zoom,Axis 111 TO 2390 AXISQ6075-E 1 $ Ordering Number Logic:TO 2390 Axis AXISQ6075-E,or approved equivalent CCTV Connector per the following and per State of Florida Approved Products List: Camera Pendant Mount Kit T94A01d 112 TO 2391 Ordering Logic Number:TO 2391 1 $ AXIS-Q6075-E Camera Pendant Mount Kit CCTV Connector per the following and per State of Florida Approved Products List: RJ45 push pull plug connector kit 5700-371 113 TO 2395 Ordering Logic Number:TO 2395 6100- 1 $ AXIS-RJ45-OUT CCTV Camera Power Supply per the following and per State of Florida Approved Products List: 114 TO 2393 Single port High PoE midspan,60 W. 1 $ Compliant with IEEE 802.3at and 802.3af Ordering Number Logic:TO 2393 Axis T8134 60W Midspan Power Supply 5900-334,or approved equivalent NOT AWARDED N/ TA List:145 } 2904e Ordering Logic Number:TO 290Se Cable 120"; Model 6100 AXIS CCTV Camera License per the following and N/A per State of Florida Approved Products List: Core device licenses(0879-010)for Axis 116 TO 2396 devices and 2N intercoms 1 $ Ordering Logic Number: Core device licenses(0879-010)for Axis devices and 2N intercoms CCTV Camera License per the following and N/A per State of Florida Approved Products List: Universal device licenses(0879-020) 117 TO 2397 Ordering Logic Number: 1 $ Universal device licenses(0879-020) 18 1686 NOT AWARDED Fiber Patch Yellow N/A Cord/Cables,LC/ST/3M 0S2,Duplex,w/twist 4-1-8 TO 1791 connector for Axis Camera Ordering Logic Number:TO 1791 LCSTDUPSM 3M; NOT AWARDED Fiber Patch Yellow NA- Cord/Cables, LC/SC/3M 0S2,Duplex,w/clip 4-1-9 TO 1792 connectors for Axis Camera 4- $ Ordering Logic Number:TO 1792 LCSCDUPSM 3M; NOT AWARDED following and ..State of Florid.. Approve d Products List: nagged Mo dinar Base 8 mope.pl„s 2 Fibe. 120 � Ports,Cisco IE3300 8T2S E 10 Port Ethernet } $ Switch- Ordering Number Logic: Cisco 1E3300 8T2S E,or approved equivalent NOT AWARDED Network Devices,per tho Folloy.ing and p r-State of Florid.. A pero\ed Products List: 121 TO 3301 Proline Cisco GLC LX SM RGD,Fiber SSP 4- $ Ordering Number Logic: TO 3301,or approved equivalent NOT AWARDED Network Devices,per the Products List: 122 TO 3302 Rugged,8 copper,Cisco IEM 3300 8T 8 Port 4 Ethernet Expansion Ordering Number Logic: Cisco IEM 3300 8T,or approved equivalent NOT AWARDED Products List: 123 TO 3303 50 Watts. 100 240VAC,Cisco PWR IE50W $ Ordering Number Logic: Cisco PWR IE50W AC,or approved NOT AWARDED Products List:Cisco Optical Transceiver 424 TO 3304 SMF, 1550nm,80km,LC,DOM, IOG,Cisco 4- S SFP 10G ZR S SFP Ordering Number Logic: Cisco SFP 10G ZR S,or approved equivalent NOT AWARDED Battery Meter per the N/A Products List: 125 TO 1759 Tycon system TP Battmcter 24 12V/24V T $ Battery Meter Ordering Number Logic:TO 1759 Tycon system TP Battmcter 21 19 1686 Network Devices-Wireless WIFI Router Ordering Number Logic: TO 2251: Teltonika, Model Number:RUT240 or $ 215.00 126 TO 2251 approved equivalent I Primary Award 20 1686 Other Exhibit/Attachment Description: following this page (pages through ) ❑■ this exhibit is not applicable Page 17 of 17 Fixed Term Service Multi-Contractor Agreement [2024_ver.1]