#24-8208 (Temple, Inc.) FIXED TERM SERVICE
MULTI-CONTRACTOR AWARD AGREEMENT
#24-8208
for
"TRAFFIC SIGNAL COMPONENTS & HARDWARE"
THIS AGREEMENT, made and entered into on this 21 day of Pr 09us4- 20 Zy ,
by and between Temple, INC.
authorized to do business in the State of Florida, whose business address is
305 Bank Street, Decatur, AL 35601 , (the "Contractor")
and Collier County, a political subdivision of the State of Florida, (the "County"):
WITNESSETH:
1. AGREEMENT TERM. The Agreement shall be for a one ( 1 ) year period,
commencing ❑■ upon the date of Board approval; of n en and
terminating on one ( 1 ) year(s) from that date or until all outstanding Purchase
Order(s) issued prior to the expiration of the Agreement period have been completed or
terminated.
The County may, at its discretion and with the consent of the Contractor, renew the
Agreement under all of the terms and conditions contained in this Agreement for
one ( 1 ) additional one ( 1 ) year(s) periods. The County shall give the
Contractor written notice of the County's intention to renew the Agreement term prior to
the end of the Agreement term then in effect.
The County Manager, or his designee, may, at his discretion, extend the Agreement
under all of the terms and conditions contained in this Agreement for up to one hundred
and eighty (180) days. The County Manager, or his designee, shall give the Contractor
written notice of the County's intention to extend the Agreement term prior to the end of
the Agreement term then in effect.
2. COMMENCEMENT OF SERVICES. The Contractor shall commence the work upon
issuance of a IN Purchase Order ❑ .
3. STATEMENT OF WORK. The Contractor shall provide services in accordance with the
terms and conditions of ❑ Request for Proposal (RFP) ■❑ Invitation to Bid (ITB) n
Other ( ITB ) # 24-8208 ,
including all Attachment(s), Exhibit(s) and Addenda and the Contractor's proposal
referred to herein and made an integral part of this Agreement.
❑� The Contractor shall also provide services in accordance with Exhibit A — Scope of
Services attached hereto.
Page 1 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
3.1 This Agreement contains the entire understanding between the parties and any
modifications to this Agreement shall be mutually agreed upon in writing by the Parties,
in compliance with the County's Procurement Ordinance, as amended, and Procurement
Procedures in effect at the time such services are authorized.
3.2 • The procedure for obtaining Work under this Agreement is outlined in Exhibit A —
Scope of Services attached hereto.
3 I The procedure for obtaining Work under this Agreement is outlined in n Other
Exhibit/Attachment:
3-4❑ •
4. THE AGREEMENT SUM. The County shall pay the Contractor for the performance of
this Agreement based on Exhibit B- Fee Schedule, attached hereto and the price
methodology as defined in Section 4.1. Payment will be made upon receipt of a proper
invoice and upon approval by the County's Contract Administrative Agent/Project
Manager, and in compliance with Chapter 218, Fla. Stats., otherwise known as the "Local
Government Prompt Payment Act".
4.1 Price Methodology (as selected below):
n p-Sum (Fixed Price): A firm fixertotal-price-affer+ra ;
satisfaction of the County's project manager bcforc payment for the fixed price contract
is authorized.
n Mat .
•
or payroll records), material or equipment invoices, and other reimbursable
documentation for the project.
■ Unit Price: The County agrees to pay a firm total fixed price (inclusive of all costs,
including labor, materials, equipment, overhead, etc.) for a repetitive product or service
delivered (i.e. installation price per ton, delivery price per package or carton, etc.). The
invoice must identify the unit price and the number of units received (no contractor
inventory or cost verification).
Page 2 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1I
4.2 Any County agency may obtain services under this Agreement, provided
sufficient funds are included in their budget(s).
4.3 Payments will be made for services furnished, delivered, and accepted, upon
receipt and approval of invoices submitted on the date of services or within six (6) months
after completion of the Agreement. Any untimely submission of invoices beyond the
specified deadline period is subject to non-payment under the legal doctrine of "lashes"
as untimely submitted. Time shall be deemed of the essence with respect to the timely
submission of invoices under this Agreement.
4.4 The County, or any duly authorized agents or representatives of the County, shall
have the right to conduct an audit of Contractor's books and records to verify the accuracy
of the Contractor's claim with respect to Contractor's costs associated with any Payment
Application, Change Order, or Work Directive Change.
4.5 n : Travel and
Reimbursable Expenses must be approved in advance in writing by the County. Travel
expenses shall be reimb irsed as nor Section 117 061 Fla S�a�c_
Reimbursements shall be at the following rates:
Mileage $0.44.5 per mile
Breakfast $6 00
Lunch $ 4709.
Dinner $4-97009
Air-fafe
class fare
Rehtal-eaF Actual rental cost limited to compact or
Taxi or Airport Limousine Actual cost of cithcr taxi or airport limousine
Reimbursable items-other than travel expenses shal •
items will be paid only after Contractor has provided all receipts. Contractor shall be
responsible for all other costs and expenses associated with activities and solicitations
undertaken pursuant to this Agreement.
5. SALES TAX. Contractor shall pay all sales, consumer, use and other similar taxes
associated with the Work or portions thereof, which are applicable during the performance
of the Work. Collier County, Florida as a political subdivision of the State of Florida, is
exempt from the payment of Florida sales tax to its vendors under Chapter 212, Florida
Statutes, Certificate of Exemption # 85-8015966531C.
Page 3 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
6. NOTICES. All notices from the County to the Contractor shall be deemed duly served if
mailed or emailed to the Contractor at the following:
Company Name: Temple, INC.
Address: 305 Bank Street
Decatur, AL 35601
Authorized Agent: Kenneth Temple
Attention Name & Title: CEO
Telephone: 256-353-3820, ext. 124
E-Mail(s): blair.temple@temple-inc.com
All Notices from the Contractor to the County shall be deemed duly served if mailed or
emailed to the County to:
Board of County Commissioners for Collier County, Florida
Division Director: Jay Ahmad
Division Name: Transportation Engineering
Address: 2885 South Horseshoe Drive
Naples FL 34104
Administrative Agent/PM: Leandro Goicoechea
Telephone: 239-252-5178
E-Mail(s): leandro.goicoechea@colliercountyfl.gov
The Contractor and the County may change the above mailing address at any time upon
giving the other party written notification. All notices under this Agreement must be in
writing.
7. NO PARTNERSHIP. Nothing herein contained shall create or be construed as creating a
partnership between the County and the Contractor or to constitute the Contractor as an
agent of the County.
8. PERMITS: LICENSES: TAXES. In compliance with Section 218.80, F.S., all permits
necessary for the prosecution of the Work shall be obtained by the Contractor. The County
will not be obligated to pay for any permits obtained by Subcontractors.
Payment for all such permits issued by the County shall be processed internally by the
County. All non-County permits necessary for the prosecution of the Work shall be
procured and paid for by the Contractor. The Contractor shall also be solely responsible
for payment of any and all taxes levied on the Contractor. In addition, the Contractor shall
comply with all rules, regulations and laws of Collier County, the State of Florida, or the
U. S. Government now in force or hereafter adopted. The Contractor agrees to comply
with all laws governing the responsibility of an employer with respect to persons employed
by the Contractor.
Page 4 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.I]
9. NO IMPROPER USE. The Contractor will not use, nor suffer or permit any person to use
in any manner whatsoever, County facilities for any improper, immoral or offensive
purpose, or for any purpose in violation of any federal, state, county or municipal
ordinance, rule, order or regulation, or of any governmental rule or regulation now in effect
or hereafter enacted or adopted. In the event of such violation by the Contractor or if the
County or its authorized representative shall deem any conduct on the part of the
Contractor to be objectionable or improper, the County shall have the right to suspend the
Agreement of the Contractor. Should the Contractor fail to correct any such violation,
conduct, or practice to the satisfaction of the County within twenty-four (24) hours after
receiving notice of such violation, conduct, or practice, such suspension to continue until
the violation is cured. The Contractor further agrees not to commence operation during
the suspension period until the violation has been corrected to the satisfaction of the
County.
10. TERMINATION. Should the Contractor be found to have failed to perform his services in
a manner satisfactory to the County as per this Agreement, the County may terminate
said Agreement for cause; further the County may terminate this Agreement for
convenience with a thirty (30) day written notice. The County shall be the sole judge of
non-performance.
In the event that the County terminates this Agreement, Contractor's recovery against the
County shall be limited to that portion of the Agreement Amount earned through the date
of termination. The Contractor shall not be entitled to any other or further recovery against
the County, including, but not limited to, any damages or any anticipated profit on portions
of the services not performed.
11. NO DISCRIMINATION. The Contractor agrees that there shall be no discrimination as to
race, sex, color, creed or national origin or any other class protected by federal or Florida
law.
12. INSURANCE. The Contractor shall provide insurance as follows:
A. E■ Commercial General Liability: Coverage shall have minimum limits of
$ 1,000,000 Per Occurrence, $2,000,000 aggregate for Bodily Injury Liability
and Property Damage Liability. The General Aggregate Limit shall be endorsed to apply
per project. This shall include Premises and Operations; Independent Contractors;
Products and Completed Operations and Contractual Liability.
B. n Business Auto Liability: Coverage shall have minimum limits of$ 1,000,000
Per Occurrence, Combined Single Limit for Bodily Injury Liability and Property Damage
Liability. This shall include: Owned Vehicles, Hired and Non-Owned Vehicles and
Employee Non-Ownership.
C. ❑■ Workers' Compensation: Insurance covering all employees meeting Statutory
Limits in compliance with the applicable state and federal laws. The coverage must
include Employers' Liability with a minimum limit of$ 1,000,000 for each accident.
Page 5 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
D. n
liability for claims arising out of the performance of professional services under this
Agreement. Contractor waives its right of recovery against County as to any claims under
this insurance. Such insurance shall have limits of not less than $ each
claim and aggregate.
&n .
l ❑ : Coverage
G, ❑ -G.everage
shall have minimum limits of$ per claim.
147 -G overage
Special Requirements: Collier County Board of County Commissioners, OR, Board of
County Commissioners in Collier County, OR, Collier County Government shall be listed
as the Certificate Holder and included as an "Additional Insured" on the Insurance
Certificate for Commercial General Liability where required. This insurance shall be
primary and non-contributory with respect to any other insurance maintained by, or
available for the benefit of, the Additional Insured and the Contractor's policy shall be
endorsed accordingly.
Current, valid insurance policies meeting the requirement herein identified shall be
maintained by Contractor during the duration of this Agreement. The Contractor shall
provide County with certificates of insurance meeting the required insurance provisions.
Renewal certificates shall be sent to the County thirty (30) days prior to any expiration
date. Coverage afforded under the policies will not be canceled or allowed to expire until
the greater of thirty (30) days prior written notice, or in accordance with policy provisions.
Contractor shall also notify County, in a like manner, within twenty-four (24) hours after
receipt, of any notices of expiration, cancellation, non-renewal or material change in
coverage or limits received by Contractor from its insurer, and nothing contained herein
shall relieve Contractor of this requirement to provide notice.
Contractor shall ensure that all subcontractors comply with the same insurance
requirements that the Contractor is required to meet.
13. INDEMNIFICATION. To the maximum extent permitted by Florida law, the Contractor
shall defend, indemnify and hold harmless Collier County, its officers and employees from
any and all liabilities, damages, losses and costs, including, but not limited to, reasonable
attorneys' fees and paralegals' fees, whether resulting from any claimed breach of this
Agreement by Contractor, any statutory or regulatory violations, or from personal injury,
property damage, direct or consequential damages, or economic loss, to the extent
caused by the negligence, recklessness, or intentionally wrongful conduct of the
Contractor or anyone employed or utilized by the Contractor in the performance of this
Page 6 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
Agreement. This indemnification obligation shall not be construed to negate, abridge or
reduce any other rights or remedies which otherwise may be available to an indemnified
party or person described in this paragraph.
This section does not pertain to any incident arising from the sole negligence of Collier
County.
13.1 The duty to defend under this Article 13 is independent and separate from the duty to
indemnify, and the duty to defend exists regardless of any ultimate liability of the Contractor,
County and any indemnified party. The duty to defend arises immediately upon
presentation of a claim by any party and written notice of such claim being provided to
Contractor. Contractor's obligation to indemnify and defend under this Article 13 will survive
the expiration or earlier termination of this Agreement until it is determined by final judgment
that an action against the County or an indemnified party for the matter indemnified
hereunder is fully and finally barred by the applicable statute of limitations.
14. AGREEMENT ADMINISTRATION. This Agreement shall be administered on behalf of
the County by the Transportation Engineering Division
15. CONFLICT OF INTEREST. Contractor represents that it presently has no interest and
shall acquire no interest, either direct or indirect, which would conflict in any manner with
the performance of services required hereunder. Contractor further represents that no
persons having any such interest shall be employed to perform those services.
16. COMPONENT PARTS OF THIS AGREEMENT. This Agreement consists of the following
component parts, all of which are as fully a part of the Agreement as if herein set out
verbatim: Contractor's Proposal, Insurance Certificate(s), ■ Exhibit A Scope of Services,
Exhibit B Fee Schedule, fI RFP/ ■ ITB/I I Other
#24-8208 , including Exhibits, Attachments and Addenda/Addendum, ❑ subsequent
quotes, and I I Other Exhibit/Attachment:
17. APPLICABILITY. Sections corresponding to any checked box ( ■ ) expressly apply to
the terms of this Agreement.
18. SUBJECT TO APPROPRIATION. It is further understood and agreed by and between
the parties herein that this Agreement is subject to appropriation by the Board of County
Commissioners.
19. PROHIBITION OF GIFTS TO COUNTY EMPLOYEES. No organization or individual
shall offer or give, either directly or indirectly, any favor, gift, loan, fee, service or other
item of value to any County employee, as set forth in Chapter 112, Part III, Florida
Statutes, Collier County Ethics Ordinance No. 2004-05, as amended, and County
Administrative Procedure 5311. Violation of this provision may result in one or more of
the following consequences: a. Prohibition by the individual, firm, and/or any employee of
the firm from contact with County staff for a specified period of time; b. Prohibition by the
individual and/or firm from doing business with the County for a specified period of time,
Page 7 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
including but not limited to: submitting bids, RFP, and/or quotes; and, c. immediate
termination of any Agreement held by the individual and/or firm for cause.
20. COMPLIANCE WITH LAWS. By executing and entering into this Agreement, the
Contractor is formally acknowledging without exception or stipulation that it agrees to
comply, at its own expense, with all federal, state and local laws, codes, statutes,
ordinances, rules, regulations and requirements applicable to this Agreement, including
but not limited to those dealing with the Immigration Reform and Control Act of 1986 as
located at 8 U.S.C. 1324, et seq. and regulations relating thereto, as either may be
amended, as well as the requirements set forth in Florida Statutes, §448.095; taxation,
workers' compensation, equal employment and safety including, but not limited to, the
Trench Safety Act, Chapter 553, Florida Statutes, and the Florida Public Records Law
Chapter 119, if applicable, including specifically those contractual requirements at F.S. §
119.0701(2)(a)-(b) as stated as follows:
IT IS THE CONTRACTOR'S DUTY TO PROVIDE PUBLIC RECORDS
RELATING TO THIS CONTRACT. IF THE CONTRACTOR HAS
QUESTIONS REGARDING THE APPLICATION OF CHAPTER 119,
FLORIDA STATUTES, IT SHOULD CONTACT THE CUSTODIAN OF
PUBLIC RECORDS AT:
Communications, Government and Public Affairs Division
3299 Tamiami Trail East, Suite 102
Naples, FL 34112-5746
Telephone: (239) 252-8999
Email: PublicRecordRequest(r colliercountyfl.gov
The Contractor must specifically comply with the Florida Public Records Law to:
1. Keep and maintain public records required by the public agency to perform the
service.
2. Upon request from the public agency's custodian of public records, provide the
public agency with a copy of the requested records or allow the records to be
inspected or copied within a reasonable time at a cost that does not exceed the
cost provided in this chapter or as otherwise provided by law.
3. Ensure that public records that are exempt or confidential and exempt from public
records disclosure requirements are not disclosed except as authorized by law
for the duration of the contract term and following completion of the contract if the
Contractor does not transfer the records to the public agency.
4. Upon completion of the contract, transfer, at no cost, to the public agency all
public records in possession of the Contractor or keep and maintain public
records required by the public agency to perform the service. If the Contractor
transfers all public records to the public agency upon completion of the contract,
the Contractor shall destroy any duplicate public records that are exempt or
confidential and exempt from public records disclosure requirements. If the
Page 8 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
Contractor keeps and maintains public records upon completion of the contract,
the Contractor shall meet all applicable requirements for retaining public records.
All records stored electronically must be provided to the public agency, upon request from
the public agency's custodian of public records, in a format that is compatible with the
information technology systems of the public agency.
If Contractor observes that the Contract Documents are at variance therewith, it shall
promptly notify the County in writing. Failure by the Contractor to comply with the laws
referenced herein shall constitute a breach of this Agreement and the County shall have
the discretion to unilaterally terminate this Agreement immediately.
21. OFFER EXTENDED TO OTHER GOVERNMENTAL ENTITIES. Collier County
encourages and agrees to the successful Contractor extending the pricing, terms and
conditions of this solicitation or resultant Agreement to other governmental entities at the
discretion of the successful Contractor.
22. PAYMENTS WITHHELD. The County may decline to approve any application for
payment, or portions thereof, because of defective or incomplete work, subsequently
discovered evidence or subsequent inspections. The County may nullify the whole or any
part of any approval for payment previously issued and the County may withhold any
payments otherwise due to Contractor under this Agreement or any other Agreement
between the County and Contractor, to such extent as may be necessary in the County's
opinion to protect it from loss because of: (a) defective Work not remedied; (b) third party
claims failed or reasonable evidence indicating probable fling of such claims; (c) failure of
Contractor to make payment properly to subcontractors or for labor, materials or
equipment; (d) reasonable doubt that the Work can be completed for the unpaid balance
of the Contract Amount; (e) reasonable indication that the Work will not be completed
within the Contract Time; (f) unsatisfactory prosecution of the Work by the Contractor; or
(g) any other material breach of the Contract Documents.
If any conditions described above are not remedied or removed, the County may, after
three (3) days written notice, rectify the same at Contractor's expense. The County also
may offset against any sums due Contractor the amount of any liquidated or unliquidated
obligations of Contractor to the County, whether relating to or arising out of this Agreement
or any other Agreement between Contractor and the County.
If a subcontractor is a related entity to the Contractor, then the Contractor shall not mark-
up the subcontractor's fees. A related entity shall be defined as any Parent or Subsidiary
of the Company and any business, corporation, partnership, limited liability company or
other entity in which the Company or a Parent or a Subsidiary of the Company holds any
ownership interest, directly or indirectly.
23. n CLEAN UP. Contractor agrees to keep the Project site clean at all times of debris,
rubbish and waste materials arising out of the Work. At the completion of the Work,
Contractor shall remove all debris, rubbish and waste materials from and about the Project
Page 9 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.t]
site, as well as all tools, appliances, construction equipment and machinery and surplus
materials, and shall leave the Project site clean.
24. STANDARDS OF CONDUCT: PROJECT MANAGER, SUPERVISOR, EMPLOYEES.
The Contractor shall employ people to work on County projects who are neat, clean,
well-groomed and courteous. Subject to the American with Disabilities Act, Contractor
shall supply competent employees who are physically capable of performing their
employment duties. The County may require the Contractor to remove an employee it
deems careless, incompetent, insubordinate or otherwise objectionable and whose
continued employment on Collier County projects is not in the best interest of the County.
25. • WARRANTY. Contractor expressly warrants that the goods, materials and/or
equipment covered by this Agreement will conform to the requirements as specified, and
will be of satisfactory material and quality production, free from defects, and sufficient for
the purpose intended. Goods shall be delivered free from any security interest or other
lien, encumbrance or claim of any third party. Any services provided under this Agreement
shall be provided in accordance with generally accepted professional standards for the
particular service. These warranties shall survive inspection, acceptance, passage of title
and payment by the County.
Contractor further warrants to the County that all materials and equipment furnished under
the Contract Documents shall be applied, installed, connected, erected, used, cleaned
and conditioned in accordance with the instructions of the applicable manufacturers,
fabricators, suppliers or processors except as otherwise provided for in the Contract
Documents.
If, within one (1) year after final completion, any Work is found to be defective or not in
conformance with the Contract Documents, Contractor shall correct it promptly after
receipt of written notice from the County. Contractor shall also be responsible for and pay
for replacement or repair of adjacent materials or Work which may be damaged as a result
of such replacement or repair. These warranties are in addition to those implied
warranties to which the County is entitled as a matter of law.
26. • TESTS AND INSPECTIONS. If the Contract Documents or any codes, laws,
ordinances, rules or regulations of any public authority having jurisdiction over the Project
requires any portion of the Work to be specifically inspected, tested or approved,
Contractor shall assume full responsibility therefore, pay all costs in connection therewith
and furnish to the County the required certificates of inspection, testing or approval. All
inspections, tests or approvals shall be performed in a manner and by organizations
acceptable to the County.
27. • PROTECTION OF WORK.
A. Contractor shall fully protect the Work from loss or damage and shall bear the cost
of any such loss or damage until final payment has been made. If Contractor or
anyone for whom Contractor is legally liable is responsible for any loss or damage
to the Work, or other work or materials of the County or County's separate
contractors, Contractor shall be charged with the same, and any monies necessary
Page 10 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
to replace such loss or damage shall be deducted from any amounts due to
Contractor.
B. Contractor shall not load nor permit any part of any structure to be loaded in any
manner that will endanger the structure, nor shall Contractor subject any part of the
Work or adjacent property to stresses or pressures that will endanger it.
C. Contractor shall not disturb any benchmark established by the County with respect
to the Project. If Contractor, or its subcontractors, agents or anyone, for whom
Contractor is legally liable, disturbs the County's benchmarks, Contractor shall
immediately notify the County. The County shall re-establish the benchmarks and
Contractor shall be liable for all costs incurred by the County associated therewith.
28. SUBMITTALS AND SUBSTITUTIONS. Any substitution of products/materials from
specifications shall be approved in writing by the County in advance.
29. CHANGES IN THE WORK. The County shall have the right at any time during the
progress of the Work to increase or decrease the Work. Promptly after being notified of a
change, Contractor shall submit an estimate of any cost or time increases or savings it
foresees as a result of the change. Except in an emergency endangering life or property,
or as expressly set forth herein, no addition or changes to the Work shall be made except
upon modification of the Purchase Order by the County, and the County shall not be liable
to the Contractor for any increased compensation without such modification. No officer,
employee or agent of the County is authorized to direct any extra or changed work orally.
Any modifications to this Agreement shall be in compliance with the County Procurement
Ordinance and Procedures in effect at the time such modifications are authorized.
30. AGREEMENT TERMS. If any portion of this Agreement is held to be void, invalid, or
otherwise unenforceable, in whole or in part, the remaining portion of this Agreement shall
remain in effect.
31. ADDITIONAL ITEMS/SERVICES. Additional items and/or services may be added to this
Agreement in compliance with the Procurement Ordinance, as amended, and
Procurement Procedures.
32. DISPUTE RESOLUTION. Prior to the initiation of any action or proceeding permitted by
this Agreement to resolve disputes between the parties, the parties shall make a good
faith effort to resolve any such disputes by negotiation. The negotiation shall be attended
by representatives of Contractor with full decision-making authority and by County's staff
person who would make the presentation of any settlement reached during negotiations
to County for approval. Failing resolution, and prior to the commencement of depositions
in any litigation between the parties arising out of this Agreement, the parties shall attempt
to resolve the dispute through Mediation before an agreed-upon Circuit Court Mediator
certified by the State of Florida. The mediation shall be attended by representatives of
Contractor with full decision-making authority and by County's staff person who would
make the presentation of any settlement reached at mediation to County's board for
approval. Should either party fail to submit to mediation as required hereunder, the other
party may obtain a court order requiring mediation under section 44.102, Fla. Stat.
Page 11 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
33. VENUE. Any suit or action brought by either party to this Agreement against the other
party relating to or arising out of this Agreement must be brought in the appropriate federal
or state courts in Collier County, Florida, which courts have sole and exclusive jurisdiction
on all such matters.
34.
•
The Contractor shall make commercially reasonable efforts to notify Collier County within
seven (7)days of the change. The County retains final approval of proposed replacement
n AGREEMENT STAFFING. The Contractor's personnel and management to be utilized
for this Agreement shall be knowledgeable in their areas of expertise. The County
reserves the right to perform investigations as may be deemed necessary to ensure that
competent persons will be utilized in the performance of the Agreement. The Contractor
shall assign as many people as necessary to complete required services on a timely basis,
and each person assigned shall be available for an amount of time adequate to meet
required services.
35. UPI ORDER OF PRECEDENCE. In the event of any conflict between or among the terms
of any of the Contract Documents, the terms of solicitation, the Contractor's Proposal,
and/or the County's Board approved Executive Summary, the Contract Documents shall
take precedence.
Executive Summary, the terms of the Agreement shall take precedence over the terms of
36. ASSIGNMENT. Contractor shall not assign this Agreement or any part thereof, without
the prior consent in writing of the County. Any attempt to assign or otherwise transfer this
Agreement, or any part herein, without the County's consent, shall be void. If Contractor
does, with approval, assign this Agreement or any part thereof, it shall require that its
Page 12 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.11
assignee be bound to it and to assume toward Contractor all of the obligations and
responsibilities that Contractor has assumed toward the County.
37. SECURITY. The Contractor is required to comply with County Ordinance 2004-52, as
amended. Background checks are valid for five (5) years and the Contractor shall be
responsible for all associated costs. If required, Contractor shall be responsible for the
costs of providing background checks by the Collier County Facilities Management
Division for all employees that shall provide services to the County under this Agreement.
This may include, but not be limited to, checking federal, state and local law enforcement
records, including a state and FBI fingerprint check, credit reports, education, residence
and employment verifications and other related records. Contractor shall be required to
maintain records on each employee and make them available to the County for at least
four(4)years. All of Contractor's employees and subcontractors must wear Collier County
Government Identification badges at all times while performing services on County
facilities and properties. Contractor ID badges are valid for one (1) year from the date of
issuance and can be renewed each year at no cost to the Contractor during the time
period in which their background check is valid, as discussed below. All technicians shall
have on their shirts the name of the contractor's business.
The Contractor shall immediately notify the Collier County Facilities Management Division
via e-mail (DL-FMOPS@colliercountyfl.gov) whenever an employee assigned to Collier
County separates from their employment. This notification is critical to ensure the
continued security of Collier County facilities and systems. Failure to notify within four (4)
hours of separation may result in a deduction of$500 per incident.
Collier County Sheriff's Office (CCSO) requires separate fingerprinting prior to work being
performed in any of their locations. This will be coordinated upon award of the contract. If
there are additional fees for this process, the Contractor is responsible for all costs.
38. ❑■ SAFETY. All Contractors and subcontractors performing service for Collier County are
required and shall comply with all Occupational Safety and Health Administration (OSHA),
State and County Safety and Occupational Health Standards and any other applicable
rules and regulations. Also, all Contractors and subcontractors shall be responsible for
the safety of their employees and any unsafe acts or conditions that may cause injury or
damage to any persons or property within and around the work site.
Collier County Government has authorized the Occupational Safety and Health
Administration (OSHA) to enter any Collier County Facility, property and/or right-of-way
for the purpose of inspection of any Contractor's work operations. This provision is non-
negotiable by any division/department and/or Contractor. All applicable OSHA inspection
criteria apply as well as all Contractor rights, with one exception. Contractors do not have
the right to refuse to allow OSHA onto a project that is being performed on Collier County
Property. Collier County, as the owner of the property where the project is taking place
shall be the only entity allowed to refuse access to the project. However, this decision
Page 13 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
shall only be made by Collier County's Risk Management Division Safety Manager and/or
Safety Engineer.
IN WITNESS WHEREOF, the parties hereto, by an authorized person or agent, have executed
this Agreement on the date and year first written above.
ATTEST: BOARD OF COUNTY COMMISSIONERS
Crystal K. Kinzel, Clerk of the Circuit COLLIER U TY, FLORIDA
Court and Comptroller
By: 11,t.�- '� �tf l-ic d etiti By:
nn Atte t as to Chao„ ,,;s Ch all , Chairman
Dated:. �h SIE signature only
(SEAL)
•
Contractor's Witnesses: Temple, INC.
Contractor
DBA
By: _:;14-e"
ntractor's First Witness S'4gn9,turp___
�o t -e;t ((�� �cc�s c i f c� Ste- S
rrce,S+ ) Q TType/print signature a titleT
TType/print witness na' n ri eT
00Aa-iak-Q
Contractor's Second Witness
-Test, 1 u
TType/print witness nameT
A roved as to F" Legality:
County_Attorney
Print Name
Page ldofl7
Fixed Term Service Multi-Contractor Agreement
[2024_ver.I]
Exhibit A
Scope of Services
❑■ following this page (pages 1 through 23
❑ this exhibit is not applicable
Page 15 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
INVITATION TO BID(ITB)#24-8208
"TRAFFIC SIGNAL COMPONENTS AND HARDWARE"
EXHIBIT A
SCOPE OF SERVICES
DETAILED SCOPE OF WORK:
In accordance with Florida Statutes Chapter 316.0745, and in addition to any applicable Federal Highway
Administration Manual on Uniform Traffic Control Devices(MUTCD) requirements, all traffic control signals and
devices sold or installed in the state of Florida must conform to the Florida Department of Transportation Standard
Specifications for Road and Bridge Construction,and be listed on the FDOT Approved Product List,see link below:
https://www.fdot.gov/p rogramm anagem ent/produ ctev al uati on/ap l/de fau l t.shtm
https://fdotwpl.dot.state.fl.us/Approv cdProductL ist/Specifications
Bid prices shall include delivery to the following address:
2885 South Horseshoe Drive,Naples,Florida 34104.
Traffic Signal Heads(Vehicular)
CCTO 1502
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
• Signal Head: Three (3) Section Horizontal configuration per MUTCD Part 4, Figure 4D-6 (B —Typical
Arrangements)
• Visor: Tunnel
• Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red,Solid Yellow,Solid Green.
• 15-year performance warranty on optical unit.
• Color of Signal Head: Black
• Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Red Signal:APL Number:650-010-038
12"LED Yellow Signal:APL Number:650-012-023
12"LED Green Signal:APL Number:650-013-026
CCTO 1506
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Signal Head: Three (3) Section Horizontal configuration per MUTCD Part 4, Figure 4D-10 (B—Typical
Arrangements)
b. Visor: Tunnel
c. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Green.
d. 15-year performance warranty on optical unit.
e. Color of Signal Head: Black
f. Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Arrow Red Signal:APL Number: 650-011-027
12"LED Arrow Yellow Signal:APL Number:650-014-019
12"LED Arrow Green Signal:APL Number: 650-015-019
CCTO 1509
1
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Signal Head: Four (4) Section Horizontal configuration per MUTCD Part 4, Figure 4D-12 (B —Typical
Arrangements)
b. Visor: Tunnel
c. Optical Unit: Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Yellow,
Arrow Green.
d. 15-year performance warranty on optical unit.
e. Color of Signal Head: Black
f. Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Arrow Red Signal:APL Number: 650-011-027
12"LED Arrow Yellow Signal:APL Number: 650-014-019
12"LED Arrow Green Signal:APL Number: 650-015-019
CCTO 1510
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Signal Head: Five (5) Section Horizontal configuration per MUTCD Part 4, Figure 4D-11 (B —Typical
Arrangements)
b. Visor: Tunnel
c. Optical Unit: Light Emitting Diode (LED) 12-inch Diameter, Solid Red, Solid Yellow, Arrow Yellow,
Arrow Green,&Solid Green.
d. 15-year performance warranty on optical unit.
e. Color of Signal Head: Black
f. Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Red Signal:APL Number: 650-010-038
12"LED Yellow Signal:APL Number:650-012-023
12"LED Arrow Yellow Signal:APL Number: 650-014-019
12"LED Arrow Green Signal:APL Number: 650-015-019
12"LED Green Signal:APL Number: 650-013-026
CCTO 1511
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Signal Head: Four (4) Section Vertical configuration per MUTCD Part 4, Figure 4D-12 (B — Typical
Arrangements)
b. Visor: Tunnel
c. Optical Unit: Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Yellow,
Arrow Green.
d. 15-year performance warranty on optical unit.
e. Color of Signal Head: Black
f. Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Right Arrow Red Signal:APL Number: 650-011-027
12"LED Right Arrow Yellow Signal:APL Number:650-014-019
12"LED Right Arrow Green Signal:APL Number: 650-015-019
CCTO 1512
2
Signal,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Signal Head:Five(5)Section Vertical Cluster configuration per MUTCD Part 4,Figure 4D-11 (B—Typical
Arrangements)
b. Visor: Tunnel
c. Optical Unit: Light Emitting Diode (LED) 12-inch Diameter, Solid Red, Solid Yellow, Solid Green &
Arrow Yellow,Arrow Green.
d. 15-year performance warranty on optical unit.
e. Color of Signal Head: Black
f. Material:Aluminum
Ordering Number Logic:
Mobotrex Traffic Signal housing or approved equivalent&Dialight LED or approved equivalent
12"Die Cast Vehicle Signal:APL Number:650-002-011
12"LED Red Signal:APL Number:650-010-038
12"LED Yellow Signal:APL Number:650-012-023
12"LED Green Signal:APL Number:650-013-026
12"LED Arrow Yellow Signal:APL Number:650-014-019
12"LED Arrow Green Signal:APL Number: 650-015-019
CCTO 1513(solid)
Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List:
a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red,Solid Yellow,Solid Green.
b. 15-year performance warranty on optical unit.
1) Ordering Number Logic:
CCTO 1513-R 12"Dialight LED Red Signal or approved equivalent
APL Number: 650-010-038
2) Ordering Number Logic:
CCTO 1513-Y 12"Dialight LED Yellow Signal or approved equivalent
APL Number: 650-012-023
3) Ordering Number Logic:
CCTO 1513-G 12"Dialight LED Green Signal or approved equivalent
APL Number: 650-013-026
CCTO 1513(Arrow)
Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List:
a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Arrow Red,Arrow Yellow,Arrow Green.
b. 15-year performance warranty on optical unit.
4) Ordering Number Logic:
CCTO 1513a-RA 12"Dialight LED Arrow Red Signal or approved equivalent
APL Number: 650-011-027
5) Ordering Number Logic:
CCTO 1513a-YA 12"Dialight LED Arrow Yellow Signal or approved equivalent
APL Number:650-014-019
6) Ordering Number Logic:
CCTO 1513a-GA 12"Dialight LED Arrow Green Signal or approved equivalent
APL Number: 650-015-019
CCTO 1513(U-Turn)
Signal,Vehicle Traffic Control LED inserts per the following:
a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,U-Turn Red,U-Turn Yellow,U-Turn Green.
b. 15-year performance warranty on optical unit.
7) Ordering Number Logic:
CCTO 1513b-RU 12"Dialight LED U-Turn Red Signal or approved equivalent
8) Ordering Number Logic:
CCTO 1513b-YU 12"Dialight LED U-Turn Yellow Signal or approved equivalent
9) Ordering Number Logic:
3
CCTO 1513b-GU 12"Dialight LED U-Turn Green Signal or approved equivalent
CCTO 1513(12 Volt)
Signal,Vehicle Traffic Control LED inserts per the following and per State of Florida Approved Products List:
a. Optical Unit:Light Emitting Diode(LED) 12-inch Diameter,Solid Red and Solid Yellow.
b. Operating Voltage: 10-30V DC optical unit.
c. Lens Type:Tinted
10)Ordering Number Logic:
CCTO 1513-RF 12" Dialight 10-30 V DC LED Red Signal, Part Number: 433-1210-005XL or approved
equivalent
11) Ordering Number Logic:
CCTO 1513-YF 12"Dialight 10-30 V DC LED Yellow Signal, Part Number: 433-3230-905XL or approved
equivalent
CCTO 1532—Visors/Louvers
Signal Visor,Vehicle Traffic Control per the following and per State of Florida Approved Products List:
a. Type:Tunnel
b. Color:Flat Black
c. Size: 12 inch
d. Material:Aluminum
Ordering Number Logic:
Mobotrex housing Visor or approved equivalent APL Number:650-002-011
Traffic Signal Back Plates
CCTO 3002
Backplates, Eagle Horizontal I-Section Eagle Signal Head per the following and per State of Florida Approved
Products List:
a. Louvered with 2"Reflective 3M Tape
b. Material:Aluminum
c. Color:Black
d. Number of Sections: 1
e. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3002 Transportation Control Systems Part No.BP-5001B-F or approved equivalent
APL Number:650-022-004
CCTO 3004
Backplates, Eagle Horizontal 2-Section Signal Head per the following and per State of Florida Approved Products
List:
a. Louvered with 2"Reflective 3M Tape
b. Material:Aluminum
c. Color:Black
d. Number of Sections:2
e. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3004 Transportation Control Systems Part No BP-5002B-F.or approved equivalent
APL Number: 650-022-004
CCTO 3008
Back plates, Eagle Horizontal 3-Section Signal Head per the following and per State of Florida Approved Products
List:
a. Louvered with 2"Reflective 3M Tape
b. Material:Aluminum
c. Color:Black
d. Number of Sections:3
4
e. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3008 Transportation Control Systems Part No.BP-5003B-F or approved equivalent
APL Number: 650-022-004
CCTO 3010
Backplates, Eagle Horizontal 4-Section Signal Head per the following and per State of Florida Approved Products
List:
a. Louvered with 2"Reflective 3M Tape
b. Material:Aluminum
c. Color:Black
d. Number of Sections:4
e. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3010 Transportation Control Systems Part No.BP-5004B-F or approved equivalent
APL Number: 650-022-004
CCTO 3012
Back plates,Horizontal 5-Section Signal Head per the following and per State of Florida Approved Products List:
a. Louvered with 2"Reflective 3M Tape
b. Material:Aluminum
c. Color:Black
d. Number of Sections:5
e. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3012 Transportation Control Systems Part No.BP-5005B-F or approved equivalent
APL Number: 650-022-004
CCTO 3014
Backplates,Vertical 5-Section Signal Head per the following and per State of Florida Approved Products List:
a. Cluster Mast Arm Mount
b. Louvered with 2"Reflective 3M Tape
c. Material:Aluminum
d. Color:Black
e. Number of Sections:5
f. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3014 Transportation Control Systems Part No.BP-5007B-F or approved equivalent
APL Number: 650-022-004
CCTO 3016
Backplates,Cluster 5-Section Signal Head per the following and per State of Florida Approved Products List:
a. Cluster Span Wire Mount
b. Louvered with 2"Reflective 3M Tape
c. Material:Aluminum
d. Color:Black
e. Number of Sections:5
f. Signal Head Type:Aluminum
Ordering Number Logic:
CCTO 3016 Transportation Control Systems Part No.BP-5021 B-F or approved equivalent
APL Number: 650-022-004
Traffic Signal Heads(Pedestrian)
CCTO 1540
Signal,Pedestrian Traffic Control per the following and per State of Florida Approved Products List:
5
a. Housing: 16"X 18"
b. Material:Die Cast Aluminum
c. Color:Flat Black
d. Optical Unit: LED
e. Includes Countdown Feature
f. Symbol:Filled Icon Hand and Person 16"X 18"Module 9"x 3 '/<"Digits w/Class 3 Message Size(11"x7")
g. Symbol:Full Hand&Full Person with egg crate type visor
Ordering Number Logic:
Mobotrex housing Model SG7SZ20C3FFF10-21 or approved equivalent &Dialight Corporation,Model 430-
6479-805XF or approved equivalent
Mobotrex Pedestrian housing:
APL Number:653-024-002
Dialight Countdown Pedestrian Module
APL Number:653-022-014
CCTO 1542
Signal,Pedestrian Traffic Control Module per the following and per State of Florida Approved Products List:
a. Optical Unit:LED Single module
b. Symbol:Filled Icon Hand and Person 16"Module 9"x 3 '/<"Digits w/Class 3 Message Size(11"x7")
c. Includes Countdown Feature
d. Symbol:Full Hand&Full Person.
Ordering Number Logic:
Dialight Corporation.Model 430-6479-805XF or approved equivalent
APL Number:653-022-014
Signal Head Auxiliaries(Vehicular and Pedestrian Signals)
CCTO 2922 Mast Arm Bracket Kits
Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products
List:
a. Material:Aluminum
b. Hardware:Stainless Steel
c. Number of cables: 1
d. Cable Length: Minimum 120 inches
Ordering Number Logic:
CCTO 2922g Pelco Products, Inc., Model Number: SP-1006-FL-3-120-PNC (3-section) or approved
equivalent
APL Number: 659-031-011
CCTO 2922h Pelco Products, Inc., Model Number: SP-1006-FL-4-120-PNC (4-section) or approved
equivalent
APL Number: 659-031-011
CCTO 2922i Pelco Products,Inc.,Model Number:SP-1006-FL-5-120-PNC(5-section)or approved equivalent
APL Number:659-031-011
CCTO 2908a
Mast arm Astro-Brac Stellar clamp Mount Assembly per the following and per State of Florida Approved Products
List:
a. Material:Aluminum
b. Hardware: Stainless Steel
c. Number of cables: 1
d. Cable Length:Minimum 120 inches to minimum 144 inches
Ordering Number Logic:
CCTO 2908a Pelco Products,Inc.Model Number:SP-1079-FL-120-PNC or approved equivalent
APL Number: 659-031-009
6
C: - )
CCTO 2928 Clamp Mount Assembly
Mast arm Astro-Brac Steller Articulating clamp Mount Assembly per the following and per State of Florida Approved
Products List:
a. Bracket Articulated Mounting.
b. Finish:Standard
c. Hardware:Stainless Steel
d. Cable Length:Minimum 96"TO 120"
Ordering Number Logic:
CCTO 2928a Pelco Products,Inc.,Part No.SP-1118-FL-96-PNC or approved equivalent
APL Number:659-031-019
CCTO 2928b Pelco Products,Inc.,Part No. SP-1118-FL-120-PNC or approved equivalent
APL Number:659-031-019
CCTO 2926
Hanger Assembly,Tri-Stud per the following and per State of Florida Approved Products List:
a. Span Wire Clamp,Aluminum
b. Cast Aluminum Upper and Lower Hanger
c. Includes Stainless Steel Hardware
Ordering Number Logic:
Pelco Products,Inc.,Part No.SP-1050-FL-PNC or approved equivalent
APL Number:659-037-003
CCTO 2924
Hanger,Disconnect per the following and per State of Florida Approved Products List:
a. Door:Single Door
b. Material: Cast Aluminum with Stainless Steel Hardware.
c. Top:Non-Threaded Top&Tri-Stud Hub
d. Side Entrance Cover:Neoprene Grommet.
e. Color: Flat Black
f. Include Disconnect Hub Assembly,Tri-Stud
g. Exclude Terminal Block&Harness Assemblies
Ordering Number Logic:
Pelco Products Inc.,Part No.: SP-1021-FL-2-P34 or approved equivalent
APL Number:659-004-018
CCTO 2940
Bracket Assembly,Tri-Stud Upper Arm per the following and per State of Florida Approved Products List:
a. Direction: 2-Way
b. Material:Aluminum
c. Tri-stud kit Material: Stainless Steel.
d. Color:Flat Black
Ordering Number Logic:
Pelco Products,Inc.,Part No.SP-1026-FL-P34 or approved equivalent
APL Number: 659-001-030
CCTO 2942
Bracket Assembly,Single Stud Lower Arm per the following and per State of Florida Approved Products List.
a. Direction: 2-Way
b. Material:Aluminum
c. Hardware Kit Material: Stainless Steel.
d. Color: Flat Black
Ordering Number Logic:
Pelco Products,Inc.Part No.SP-1027-FL-P34 or approved equivalent
APL Number: 659-001-031
7
•
`tip
CCTO 1602
Pedestrian Bracket Assemblies—Upper Tri-Stud,Aluminum side of pole-per the following and per State of Florida
Approved Products List:
a. Tri-Stud Upper Arm Assembly
b. 1-way,Aluminum
c. Stainless Steel Fasteners
d. Color:Black
Ordering Number Logic:
Pelco Products Inc.Part Number:SP-1011-FL-P34 or approved equivalent
APL Number: 653-001-004
CCTO 1604
Pedestrian Bracket Assemblies, Lower Tri-Stud Aluminum side of pole, per the following and per State of Florida
Approved Products List:
a. Tri-Stud Lower Arm Assembly
b. 1-way,Aluminum
c. Stainless Steel Fasteners
d. Color:Black
Ordering Number Logic:
Pelco Products Inc.Part Number: SP-1012-FL-P34 or approved equivalent
APL Number:653-001-003
CCTO 1518
Closure Assembly,Vehicle Traffic Control Signal per the following and per State of Florida Approved Products List:
Signal head closure kit
Ordering Number Logic:
TO 1518:Pelco Products,Inc. SE-3054-P02 or approved equivalent
CCTO 2952
Post Top Adapter(Slip Fitter),Pedestrian Traffic Control Signal per the following and per State of Florida Approved
Products List
a. Aluminum Tri-Stud Adapter for use with 4-1/2 inch OD Aluminum Pole
b. Fasteners:Stainless Steel
c. Color:Natural
Ordering Number Logic:
CCTO 2952 Pelco Products,Inc.Part No.,EC-3004-T-PNC or approved equivalent
APL Number:659-009-001
CCTO 2954c
Pole,Spun Aluminum,Schedule 40,per the following and per State of Florida Approved Products List:
a. Size:4.5 inch OD
b. Length:7'
c. Material:Aluminum
d. Threaded:One End
e. Finish:Natural
Ordering Number Logic:
CCTO 2954c Pelco Products,Inc.Part No.,PB-5100-7-PNC or approved equivalent
CCTO 2959
Sign Mountings per the following and per State of Florida Approved Products List:
e. Anchor Bolt Sets
f. Quantity: Set of 4
g. Anchor bolt Size: 3/4"-1 ONC
h. Length: 18"
i. Paint:None
j. Exterior:Galvanized
8
C,
k. Includes 4 each:Bolts,Washers and Nuts
Ordering Number Logic:
Pelco Products Inc.,Part Number: PB-5543-GLV
CCTO 2960
Pedestal Base,Aluminum,per the following and per State of Florida Approved Products List:
a. Size: 13-5/8 inches x 13-5/8 inches x 15 inches high per the following:
b. Material:Aluminum with plastic Door
c. Threaded for 4.5-inch OD aluminum pole
d. Finish:Natural
e. Include grounding lug
f. No set screws in collar
Ordering Number Logic:
Pelco Products,Inc.Part No.SP-1116-FL-GL-PNC or approved equivalent
APL Number:646-001-001
CCTO 2962
Collar Assy.,Square Base, Aluminum,per the following and per State of Florida Approved Products List:
a. Finish:Natural
Ordering Number Logic:
Pelco Products,Inc.Part No.PB-5325-PNC or approved equivalent
APL Number:646-001-005
CCTO 2981b
Sign Hanger Assembly, Mast arm, and Free-Swinging Cable Mount per the following and per State of Florida
Approved Products List.
Mast Arm Mini-Brac Mount Cable Length: 84";Paint no color
Ordering Number Logic:
TO 2981b:Pelco Products,Inc.Part No.: SP-1072-FL-84-PNC or approved equivalent
CCTO 2984
Traffic Signal Hardware, Components, Pipe Fittings per the following and per State of Florida Approved Products
List:
a. 1'/"Grommet,Neoprene w/Diaphragm for disconnect cable openings
b. Color:Black
Ordering Number Logic:
Pelco Products Inc.Part No.SE-0449-PNC or approved equivalent
CCTO 2986
Traffic Signal Hardware, Components, Pipe Fittings per the following and per State of Florida Approved Products
List:
a. Double Serrated Lock ring,Aluminum
Ordering Number Logic:
Pelco Products Inc.Part No. SE-0451-PNC or approved equivalent
CCTO 2994
Traffic Signal Hardware,Extension(Extender)per the following and per State of Florida Approved Products List:
a. Material:Aluminum
b. Length:72 inches
Ordering Number Logic:
Pelco Products Inc.Part No.SE-0507-72-PNC or approved equivalent
APL Number:659-015-003
CCTO 3030
Pole Cap per the following and per State of Florida Approved Products List:
a. Acorn Type
9
•
b. Material:Aluminum
c. For 4-1/2"O.D.Pole
d. Fasteners:Stainless Steel
e. Paint:None
Ordering Number Logic:
Pelco Products Inc.,Part Number:PB-5401-PNC or approved equivalent
APL Number:746-001-009
CCTO 3126
Utility Pole Hardware per the following:
a. 7/8"Fiberglass Insulator Minimum Strength(lb)-36,000
b. 7/8"Rod Diameter,Rod Length 120"(10ft),End Fittings-Clevis w/Roller-Clevis-Clevis-2 Roller
Ordering Number Logic:
Ordering Number Logic:TO 3126 Hubbell Power Systems:Model: GS36120CC2
Detection(Pedestrian Detection System)
CCTO 1806
Pushbutton, Pedestrian Detector (Momentary LED Model) per the following and per State of Florida Approved
Products List:
a. Minimum 2-inch Actuator,A.D.A.Compliant.
b. Operating Force:2 lbs. Maximum
c. Operating Voltage: 12-36VDC or 9-25VAC RMS
d. On Resistance: 85 f2 Typical.
e. Operating Mode:Approx.0.025 sec flash each time button is pressed.
f. Viewing Angle: 155°
Ordering Number Logic:
Polara Bulldog III BDL3-B or approved equivalent
CCTO 1808
Pushbutton, Pedestrian Detector, Aluminum Push Button Cup, per the following and per State of Florida Approved
Products List:
a. Aluminum cup for mounting the BullDog Pedestrian Detector.
b. Color:Black
Ordering Number Logic:
Polara Aluminum Push Button Cup APBC2-B or approved equivalent
CCTO 1812
Pushbutton, Pedestrian Detector, Audible/Tactile Pedestrian Detector with Pedestrian Station Monitor, per the
following and per State of Florida Approved Products List:
a. Push Button:ADA Compliant,raised tactile arrow on button,solid state switch rated to 20 million actuations
minimum.
b. Construction:Die-cast aluminum,powder coated Black
c. Confirmation of button push via latching LED,sound,and vibrotactile bounce.
d. Direction of travel(with extended button push).
e. Standard locating tone during Don't Walk(and clearance if desired).
f. Cuckoo,chirp,or standard voice message during walk.
g. Vibrating button during walk.
h. Standard locating tone,custom sound,or verbal countdown during PED clearance.
i. All sounds automatically adjust to ambient over 60dB range.
j. Most sounds can have minimum and maximum volume independently set.
k. All sounds are synchronized.
1. Extended button push can turn on,boost volumes,and/or mute all sounds except those on activated crosswalk.
m. Special emergency messages available.
n. Custom locating tone
o. Informational message
10
p. Custom walk sounds/message
q. Custom clearance sound
r. Multiple languages(up to three,selectable by user)
s. 9"x15"MUTCD R10-3e pedestrian sign(Option A)
Ordering Number Logic:
Polara 2 Wire Navigator Push Button Station EN23TN1-B or approved equivalent
APL Number:665-004-004
Detection(Inductive Loop Detector)
CCTO 1704
Detector,Dual Channel Rack Mount Loop with Delay&Extend Detection per the following and per State of Florida
Approved Products List:
Inductive loop detectors shall meet the following specifications
a. Back-lit LCD screen that displays complete detector status and function settings.
b. TrueCount version(Model 1201 Only)provides 97%to 99%count accuracy when used with either a single
long loop or multiple 6'x 6' loops connected together.
c. Audible detect signal(buzzer)facilitates loop and/or detector troubleshooting.
d. Upgrades or addition of user specific options are accomplished by changing the socket mounted processor.
e. Push button programming.
f. All programmed detector parameters are stored in non-volatile memory.
g. Directional logic capability.
Ordering Number Logic:
CCTO 1704 Eberle Design Inc.,Reno A&E,Part No.C-1200 Type C with timings or approved equivalent
APL Number:660-017-003
Traffic Controller
CCTO 2010
Controller,Traffic NEMA TS2,Type 2 per the following and per State of Florida Approved Products List:
a. Intelight X3 NEMA TS2,Type 2
b. NEMA MSA,MSB,MSC,and MSD Connectors
c. Meet current ATC 5201 and 5401,NEMA TS-1 and TS-2,and NTCIP standards.
d. Compliant with current ATC 5.2b standards
e. Number Of Phases:40
f. Compatible with the existing Collier County Intelight Maxview Communications System.
Ordering Number Logic:
Intelight X3 or approved equivalent
APL Number: 671-017-013
Controller Cabinet Assembly
CCTO 2102
Cabinet,Traffic Signal Controller Assembly per the following and per State of Florida Approved Products List:
a. NEMA Standard TS2 Type 1
b. Collier County TS2-TYPE 1 Specification.
c. Cabinet assembly shall be Type 6
d. Cabinet Assembly shall include front and rear access doors.
e. 10 Circuit SDLC Interface panel.
f. Exclude Traffic Controller,M.M.U. &Loop Detectors.
g. 2 detector racks with total 32 channels of detection capability.
h. Hard wired inductive loop detector panel.
i. 8 vehicle and 8 pedestrian test switches.
j. Shall include NEMA TS2 Type 1 power supply with minimum 5.0 amp, 12 volt AC output
11
t ( : �t
k. 8 flash transfer relay sockets,includes relays.
1. 3 shelves with document drawer on lower shelf.
m. Plexiglas covered cabinet window for Photocell control panel with an on/off/auto test switch, Square D
contactor model number: 8910DPA42V02, (L1 wired to Illuminated signage and L2 wired to Street
Lighting), Square D 10 Amp circuit breaker for Illuminated Signage, and Square D 20 Amp circuit breaker
for street lighting.
n. Plexiglas Hinged Flip-up Cover for Technician Test Switches.
o. Cabinet interior illumination shall be L.E.D. located in top portion of cabinet interior and under document
door.
p. Base mounted cabinet.
q. Technician panel shall include stop time on/off/auto switch(off position shall be momentary)
r. UPS interface panel
s. Cabinet shall meet current Collier County Technical Special Provisions(See
http://www.colliergov.net/Index.aspx?page=2186)
Ordering Number Logic:
Transportation Control Systems Inc.,TS2-Type 1 Collier County or approved equivalent
APL Number:676-034-003
Controller Accessories
CCTO 2105
Cabinet,Traffic Signal Controller Assembly Power Connector Adapter Cable from TS2,Type 1 to TS2,Type 2 Traffic
Controller.
Ordering Number Logic:
Temple,Inc Part Number:ABW12027P001 or approved Equivalent
APL Number: 676-034-001
CCTO 2206a
Cabinet Power Supply,TS-2 per the following and per State of Florida Approved Products List:
a. Input:89-135 VAC
b. +12 VDC @ 5.0 Amps
c. +24 VDC @ 3.0 Amps
d. 12 VAC @ 0.25 Amps
Ordering Number Logic:
Eberle Design Inc.,Part No.EDI PS-250 or approved equivalent
APL Number:678-017-003
CCTO 2223
SmartMonitor Program Card, Malfunction Management Unit (MMU2) per the following and per State of Florida
Approved Products List:
a. Type:TS2
b. Number of Program Channels: 16
c. On-board non-volatile memory device
d. Compatible with MMU2-16LE(ip)s
Ordering Number Logic:
Eberle Design Inc.,MMU2-l6LE(ip)SmartMonitor Program Card or approved equivalent
APL Number: 678-016-005
CCTO 2224
NEMA Load Switch per the following and per State of Florida Approved Products List:
a. Solid State
b. Three(3)Independent switching circuits
c. Rated at 10A per circuit
d. Cinch-Jones socket S-2412SB,or equivalent.
Ordering Number Logic:
Power Distribution&Control,Inc.,Part No.SSS-86-3 or approved equivalent
12
APL Number:678-004-009
CCTO 2226
NEMA Flasher per the following and per State of Florida Approved Products List:
a. Type 3
b. Rated at 20 A per circuit.
Ordering Number Logic:
Power Distribution&Control,Inc.,Part No.SSF-86-3 or approved equivalent
APL Number: 678-007-007
CCTO 2227
Flasher Relay AI DC per the following and per State of Florida Approved Products List:Ordering Number Logic:
Ordering Number Logic:
AI 900-010 or approved equivalent
CCTO 2228
Bus Interface Unit(BIU)per the following and per State of Florida Approved Products List:
a. Meet or exceed all requirements of NEMA Standard TS2 for BIU Configuration.
Ordering Number Logic:
Eberle Design Inc.,Model: BIU-700 or approved equivalent
APL Number:678-018-003
CCTO 2110
4 11/16 inch Square Axial Fan per the following:
a. Fan Voltage: 115 VAC
b. Electrical Connections:Terminals.
c. Bearings:Ball
d. Rating:Minimum 100 cubic feet per minute
Ordering Number Logic:
Dayton Part Number 2RTK6 or approved equivalent
CCTO 2112
Low Voltage Surge Protector, Isolated Pedestrian Circuit Protector per the following and per State of Florida
Approved Products List:
a. Peak Surge Current: 10 kA(8 x 20 µs)
b. Voltage Clamp: 30 volts
Ordering Number Logic:
CCTO 2112 Asco Power Technologies,Surge Protector,Model: 175D030S 10KLPCNO(Edco PC642C-030)or
approved equivalent
APL Number:676-004-010
Ordering Number Logic:
CCTO 2112a Asco Power Technologies, Base, Model: PCBIB (Edco PCBIB-WKEY) or approved
equivalent
APL Number:676-004-010
CCTO 2113
10 Circuit SDLC Hub per the following and per State of Florida Approved Products List:
a. Compatible with NEMA TS2-Type 1 controller Assembly
b. Number of SDLC communication ports: 10
Ordering Number Logic:
Transportation Control Systems Inc., TS2 Traffic Signal Cabinet, 10 circuit, SDLC Hub or approved
equivalent
APL Number: 676-034-003
CCTO 2302
Flash Transfer Relay per the following and per State of Florida Approved Products List:
13
a. Meet NEMA Standard TS 2-2003
b. Pole Configuration:DPDT
c. Coil Input Voltage: 110/120 VAC 50/60 Hz
d. Contact Load Rating:20 Amps at 120 VAC
Ordering Number Logic:
Deltrol Controls,Model: 295 or approved equivalent
APL Number: 678-005-008
CCTO 2118
Filter,Traffic Cabinet AC Power Line per the following and per State of Florida Approved Products List:
a. 120VAC,60A,50/60Hz
b. UL 1283 Compliant
Ordering Number Logic:
Asco Power Technologies,Model: 250120NF060AN3N0(Edco INXT120NL000-1)or approved equivalent
CCTO 2202
NEMA TS2 Type-1 Load Bay circuit L-board per the following and per State of Florida Approved Products List:
a. Manufacturer:Eagle
Ordering Number Logic:
Mobotrex,Part Number:ACP11957P001 or approved equivalent
CCTO 2208
Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List:
a. Housing and Circuitry for one(1)BIU and 8 Two Channel Detector Cards
b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs
c. Dimensions: 14.6"W x 5.4"H x 7.5"D
Ordering Number Logic:
Mobotrex,Part Number:CDR100 or approved equivalent
APL Number:676-028-001
CCTO 2210
Rack TS2,Cabinet Detector per the following and per State of Florida Approved Products List:
a. Housing and Circuitry for one(1)BIU and 4 Two Channel Detector Cards.
b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs
c. Dimensions:9.8"W x 5.9"H x 7.1"D
Ordering Number Logic:
Mobotrex,Part Number:CDR101 or approved equivalent
APL Number:676-028-001
CCTO 2212
Rack TS2,Eagle Cabinet Detector per the following and per State of Florida Approved Products List:
a. Housing and Circuitry for one (1) BIU, 8 Two Channel Detector Cards, and one (1) GTT Opticom Phase
Selector Card.
b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs
c. Dimensions: 17.0"W x 5.9"H x 7.1"D
Ordering Number Logic:
Mobotrex,Part Number:AAD12047P001 or approved equivalent
APL Number: 676-028-001
CCTO 2214
Rack TS2,TCS Cabinet Detector per the following and per State of Florida Approved Products List:
a. Housing and Circuitry for one(1) BIU, 8 Two Channel Detector Cards, and one (1) GTT Opticom Phase
Selector Card.
b. 37 Pin Connector attached to the printed circuit board for designated inputs/outputs
c. Dimensions: 17.0"W x 5.9"H x 7.1"D
Ordering Number Logic:
14
i/%J
TCS,Part Number:TCS-413 or approved equivalent
APL Number:676-028-001
CCTO 2111
Inductive Loop Panel,TS2,Cabinet Detector per the following and per State of Florida Approved Products List:
a. PCB for 16 channels(1-16)of inductive loop detection.
b. PCB for 4 channels of GTT Infrared Opticom Detection.
c. 37 Pin Connector(J1)attached to the printed circuit board for detector rack TS2 designated inputs/outputs
d. 20 Pin Connector (J2) attached to the printed circuit board for GTT Infrared Opticom TS2 designated
inputs/outputs.
e. 6 Pin Connector(J3)attached to the printed circuit board for power TS2 designated inputs/outputs.
Ordering Number Logic:
Mobotrex,Part Number:ACP14829P002 or approved equivalent
CCTO 2201
NEMA TS2 Type-1 Load Bay circuit board per the following and per State of Florida Approved Products List:
a. Manufacturer:Transportation Control Systems Inc.
b. Description:
1. Printed Circuit Board(PCB)for Traffic Signal Cabinet Loadbay BIU 1.
Ordering Number Logic:
CCTO 2201 Transportation Control Systems Inc.,PCB for Loadbay BIU 1,TCS 223619
or approved equivalent APL Number:676-034-003
CCTO 2362
CCTV Camera Ethernet Extender components per the following and per State of Florida Approved Products List:
a. POE(power over ethernet)for CAT 5e or Cat6
b. 57V 800mA power supply for POE
Ordering Number Logic:
Veracity USA,Inc.,Part Number:VPSU-57V-800 or approved equivalent
CCTO 2374
Camera Ethernet Extender components per the following and per State of Florida Approved Products List:
a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6
b. Ethernet Interface: RJ45
c. POE injector
d. Power supply included
Ordering Number Logic:
Veracity USA,Inc.,Outreach Lite,Part Number:VOR-ORL-XT(LITE)or approved equivalent
CCTO 2375
Camera Ethernet Extender components per the following and per State of Florida Approved Products List:
a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6
b. Ethernet Interface:RJ45
c. POE injector
d. Power supply included
Ordering Number Logic:
Veracity USA,Inc.,Outreach Max,Part Number:VOR-ORM-XT(MAX)or approved equivalent
CCTO 2376
Camera Ethernet Extender components per the following and per State of Florida Approved Products List:
a. POE(Power over Ethernet)Network injector for CAT 5e or Cat6
b. Ethernet Interface:RJ45
c. POE injector
d. Power supply included
Ordering Number Logic:
Veracity USA,Inc.,Outsource,Part Number:VOR-OSP or approved equivalent
15
CCTO 2378
Ethernet Extender,Set for Cate 5e of 6;Veracity#VLS-1N-L
1 set includes:
a. (1)long range ethernet 6100-FV-VLSINL-LONGSPAN LITE POE
b. (1) 12V DC Power supply 6100-VV-VPSU12VUS-POWER SUPPLY
Ordering Number Logic:
Veracity USA,Inc.,Outsource,Part Number:VLS-1N-L or approved equivalent
CCTO 2927
Reducer Bushing, 1-1/2"NPT x 3/4"NPT,Galvanized Iron per the following:
a. Material: Galvanized Iron.
b. Reducer 1-1/2"NPT x 3/4"NPT
Ordering Number Logic:
Pelco Products Inc.,Part Number:SE-0471-GLV or approved equivalent
Sian Beacon
CCTO 1514
School Zone Flasher, Solar Powered, Single Beacon per the following and per State of Florida Approved Products
List:
a. Operation: School Zone
b. Power Source: Solar/Battery
c. Battery System: 12 VDC, 100 Ahr
d. Solar System:80 W high-efficiency photovoltaic solar panel.
e. Solar Engine Mounting:Top of Pole, 4.0"-4.5"Diameter Round Pole Mount
f. Cabinet Finish:Natural Aluminum
g. Number of Beacons:Single
h. Beacon Mounting: Single
i. Type of Beacon:Dialight, 12 VDC, 12 inch,Yellow LED.
j. Signal head Material:Aluminum
k. Signal Head Finish:Black
I. Visor Type:Tunnel
m. Integrated with the following 3rd-party Time Clock:
1. Temple FCU 500-071 (FL only)
2. RTC AP21,AP22,CPR2102,and M2M modem
n. Includes Time Clock Kit,No Clock
o. Wireless range: 1000 ft(305 m)
Ordering Number Logic:
Carmanah Technologies Corp.,Model:R829G with single beacon or approved equivalent
APL Number: 700-026-014
CCTO 1516
School Zone Flasher,Solar Powered,Dual Beacon per the following and per State of Florida Approved Products List:
a. Operation:School Zone
b. Power Source: Solar/Battery
c. Battery System: 12 VDC, 100 Ahr
d. Solar System: 80 W high-efficiency photovoltaic solar panel.
e. Solar Engine Mounting:Top of Pole,4.0"-4.5"Diameter Round Pole Mount
f. Cabinet Finish:Natural Aluminum
g. Number of Beacons:Dual
h. Beacon Mounting:Dual -Vertical
i. Type of Beacon:Dialight, 12 VDC, 12 inch,Yellow LED.
j. Signal head Material:Aluminum
k. Signal Head Finish:Black
16
1. Visor Type:Tunnel
m. Integrated with the following 3rd-party Time Clock:
1. Temple FCU 500-071 (FL only)
2. RTC AP21,AP22,CPR2102,and M2M modem
n. Includes Time Clock Kit,No Clock
o. Wireless range: 1000 ft(305 m)
Ordering Number Logic:
Carmanah Technologies Corp.,Model:R829G with dual vertical beacons or approved equivalent
APL Number: 700-026-014
CCTO 1519
Flashing Beacon,Solar Powered,Single Beacon per the following and per State of Florida Approved Products List:
a. Operation:24-7 Flashing
b. Power Source: Solar/Battery
c. Battery System: 12 V 14 Ahr.battery system
d. Solar System: 13 W high-efficiency photovoltaic solar panel.
e. Solar Engine Mounting: Single—Integrated Engine and Beacon
f. Beacon Mounting:4.0"-4.5"Diameter Round Pole Mount
g. Type of Beacon: 12 in(305 mm)diameter LED modules,yellow or red
h. Signal head Material:Aluminum
i. Signal Head Finish:Black
j. Visor Type:Tunnel
Ordering Number Logic:
CCTO 1519 Carmanah Technologies Corp.,Model:R247-E with Yellow beacon or approved equivalent
APL Number: 700-026-003
CCTO 1523
Midblock Crosswalk Enhancement Assemblies — Rectangular Rapid Flashing Beacon Assembly (RRFB) per the
following and per State of Florida Approved Products List:
a. Power Source: Solar/Battery.
b. Solar Engine Construction:Weatherproof,gasketed enclosure with vents for ambient air transfer,NEMA 3R
rated.
c. Solar Panel:30 W high-efficiency photovoltaic solar panel.
d. Battery system: 12 V 34 Ahr.
e. Solar Engine Finish:Black
f. Solar Engine Mounting:4.0"-4.5"Diameter Round Top of Pole Mount.
g. Light Bar Configuration:Single or Dual.
h. Push button:ADA-compliant,piezo-driven with visual LED and two-tone audible confirmation.
i. Push button color:Black
j. Wireless range: 1000 ft(305 m).
k. Encrypted,wireless radio with 2.4 GHz mesh technology
I. Meets or exceeds MUTCD requirements,including IA-21.
m. Flash patterns:RFB1 (WW+S),RFB2(WSDOT),0.5 sec.alternating(MUTCD),0.5 sec.unison(MUTCD),
0.1 sec.unison,0.25 sec.unison,0.1 sec. x3 quick flashes unison,0.1 sec.x3 quick flashes alternating.
Ordering Number Logic:
CCTO 1523 Carmanah Technologies Corp., Single Light Bar Configuration, Model Number: R920 or
approved equivalent
APL Number: 654-001-004
Ordering Number Logic:
CCTO 1523a Carmanah Technologies Corp., Dual Light Bar Configuration, Model Number: R920 or
approved equivalent
APL Number: 654-001-004
CCTO 3160
Electronic Display Sign(EDS)—Electronic Speed Feedback Sign(ESFS)per the following and per State of Florida
Approved Products List:
17
a. Operation: School Zone Power Source: Solar/Battery
b. Display Message LED digits: 15 inches.
c. Includes one Dialight 12-inch yellow LED beacon(MUTCD Compliant).
Ordering Number Logic:
TO 3160:Carmanah Technologies Corp.,Information Display Company,One Dialight 12-inch yellow LED.
CCTO 2205
Cellular Programmable Temple Inc. FCU-500-071 Time Switch System per the following and per State of Florida
Approved Products List:
a. Input Voltage: 16-30V DC, 120V AC.
b. Connectivity:Cellular Communications,Ethernet Port(10/100Base-T)
c. Optional 5 year Cellular connectivity plan
d. Compatible with Glance platform
e. GPS enabled for self-locating
f. Includes connector and Wiring Harness
g. Includes high gain antenna
Ordering Number Logic:
CCTO 2205 Includes 5 year Cellular connectivity plan. Temple Inc.,Part Number FCU-500-07 1 or approved
equivalent
APL Number: 678-008-023
CCTO 2106
Type 1 Wired Flasher Cabinet Assembly per the following and per State of Florida Approved Products List:
I. Operation: School Zone
m.Power Source: Solar/Battery
n. Meets NEMA 3R requirements for cabinet enclosure.
o. Constructed of 0.125"thick 5052-H32 aluminum.
p. Doubled flanged door opening on all four sides.
q. Slam Lock System that accepts#2 Corbin keys.
r. Tamperproof 14 gauge stainless steel hinge.
s. Closed-Cell Neoprene Gasket around the inside edges of the door.
t. Louvered vents on the top left and bottom right sidewalls with bug screens.
u. Back panel for equipment mounting.
v. Mounting option for flat or round surface.
w. Conforms to NEC wiring specifications.
Ordering Number Logic:
CCTO 2106 Temple Inc., Part Number: TF4001F-FL-DC with Mounting option for flat surface or approved
equivalent
APL Number: 700-026-018
Pull,Splice and Junction Boxes
CCTO 2702
Pull Box(Box)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty
c. Rated:20,000 lb.
d. Open Bottom
e. Inside Dimensions: Width: 13 Inches,Length:24 Inches,Depth: 12 Inches.
10) Ordering Number Logic:
Strongwell Quazite PG1324BA12 or approved equivalent
APL Number: 635-001-025
18
CCTO 2704
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. Manufacturer's logo shall be stamped on each pull box cover along with the words"TRAFFIC SIGNALS".
Ordering Number Logic:
Strongwell Quazite PG1324HA or approved equivalent
APL Number: 635-001-025
CCTO 6615
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. (2" Thick x 13" W x 24" L)
f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY
LIGHTING".
Ordering Number Logic:
Strongwell Quazite PG1324HA or approved equivalent
APL Number: 635-001-025
CCTO 6622
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. (1-3/9" Thick x 11" W x 18" L)
f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY
LIGHTING".
Ordering Number Logic:
Strongwell Quazite PG1118HA or approved equivalent
APL Number: 635-001-025
CCTO 6625
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. (3/4" Thick x 11" W x 18" L)
f. Manufacturer's logo shall be stamped on each pull box cover along with the words "ROADWAY
LIGHTING".
Ordering Number Logic:
Strongwell Quazite PG1118HA or approved equivalent
APL Number: 635-001-025
CCTO 2706
Pull Box(Box)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty
19
c. Rated:20,000 lb.
d. Open Bottom
e. Inside Dimensions: Width: 17 Inches,Length: 30 Inches,Depth: 12 Inches.
Ordering Number Logic:
Strongwell Quazite PG1730BA12 or approved equivalent
APL Number: 63 5-001-014
CCTO 2708
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. Manufacturer's logo shall be stamped on each pull box cover along with the words"TRAFFIC SIGNAL".
Ordering Number Logic:
Strongwell Quazite PG1730HA or approved equivalent
APL Number: 635-001-014
CCTO 2710
Pull Box(Box)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty
c. Rated:20,000 lb.
d. Open Bottom
e. Inside Dimensions:Width:24 Inches,Length:36 Inches,Depth:24 Inches.
Ordering Number Logic:
Strongwell Quazite PG2436BA24 or approved equivalent
APL Number: 635-001-012
CCTO 2712
Pull Box(Cover)per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Cover shall fit the above Pull Box
e. Manufacturer's logo shall be stamped on each pull box cover along with the words "TO
COMMUNICATIONS".
Ordering Number Logic:
Strongwell Quazite PG2436HA or approved equivalent
APL Number: 635-001-012
CCTO 2714
Pull Box per the following and per State of Florida Approved Products List:
a. Material:Polymer Concrete
b. Heavy Duty w/2 Bolts
c. Rated:20,000 lb.
d. Inside Dimensions:Width:24 Inches,Length:36 Inches,Depth: 18 Inches.
Ordering Number Logic:
Strongwell Quazite PB24360612B18 or approved equivalent
APL Number: 635-001-012
CCTO 3114
Strand Vice,3/8 inch,for Utility Grade Steel Strand per the following:
a. Primary Strand Application:3/8 inch
b. Wire Range=.325-.392
c. Bail Type:A(Standard)
20
11) Ordering Number Logic:
MacLean Power Systems,Part#5202 or approved equivalent
CCTO 3120
Cable,3/8 inch Utilities Grade Steel Strand per the following:
a. Required minimum breaking strength: 11,500 pounds.
b. Type of coating:Class A zinc coating in accordance with ASTM A475.
c. Stranding(Number X Diameter):7 X 0.120
d. 1000 ft.spool length
Ordering Number Logic:
3/8 inch Utility Grade Steel Strand
IMSA Traffic Signal Cable
CCTO 1702
Traffic Signal Cable,IMSA 50-2,Stranded,AWG 14,2 Conductors per the following:
a. IMSA Specification:50-2
b. Cable Length:5000 ft. Spool
c. Conductor Type:Stranded(19)
d. Color Code:per Specification
e. Conductor Insulation:Polyethylene
f. Cable Jacket: Black Polyethylene
g. Aluminum/Mylar Tape
12) Ordering Number Logic:
IMSA 50-2
CCTO 2602
Traffic Signal Cable,IMSA 19-1,Stranded,AWG 14 per the following:
a. IMSA Specification: 19-1
b. Cable Length:2000 ft. Spool
c. Conductor Type:Stranded(7)
d. Color Code:per Specification
e. Conductor Insulation: Polyethylene
f. Cable Jacket: Black PVC
Ordering Number Logic:
CCTO 2602 5 Conductor Traffic Signal Cable
Ordering Number Logic:
CCTO 2602a 7 Conductor Traffic Signal Cable
Ordering Number Logic:
CCTO 2602b 9 Conductor Traffic Signal Cable
Ordering Number Logic:
CCTO 2602c 12 Conductor Traffic Signal Cable
Ordering Number Logic:
CCTO 2602e 16 Conductor Traffic Signal Cable
Electrical Power Service Hardware
CCTO 2804
Load Center, 100A,Fixed-Factory installed main lugs, 120/240VAC per the following:
a. Short Circuit Current Rating: 10 kA
b. Maximum Single Pole Circuits: 12
c. Maximum Tandem Circuit Breakers:6
d. Spaces:6
21
e. Ampere Rating: 100A
f. Voltage Rating: 120/240VAC
g. Grounding Bar Included
h. Cover Type: Surface
i. Enclosure Type:Outdoor/Rainproof
j. Enclosure Rating:NEMA 3R
k. UL Listed
Ordering Number Logic:
Square D Cat.No.Q0612L100TRB or approved equivalent
Cameras
CCTO 2390
CCTV Axis PTZ Camera per the following and per State of Florida Approved Products List:
a.Include Power Supply
b.5-year Warranty Q6075-E.
Ordering Number Logic:
Model:AXIS-Q6075-E;Manufacturing part#01752-004 or approved equivalent
CCTO 2391
XIS-Q6075-E Camera Pendant Mount Kit for TO 2390- Axis Camera and per State of Florida Approved Products
List:
Ordering Number Logic:
Model Part#T94A01 D or approved equivalent
CCTO 2395
CCTV Connector per the following and per State of Florida Approved Products List:
RJ45 push pull plug connector kit 5700-371
Ordering Logic Number:TO 2395
Model:6100-AXIS-RJ45-OUT:or approved equivalent
CCTO 2393
CCTV Axis Camera power supply per the following and per State of Florida Approved Products List:
a. Include Power Supply
Ordering Number Logic:
Model: 5900-331-01 or approved equivalent
CCTO 2908c
AXIS-Sky Bracket Mount Cable per State of Florida Approved Products List:
Ordering Logic Number:TO 2908c Cable-120";Model 6100-AXIS
CCTO 2396
CCTV Camera License per the following and per State of Florida Approved Products List:
Core device licenses(0879-010)for Axis devices and 2N intercoms
Ordering Logic Number: for Axis devices and 2N intercoms
CCTO 2397
CCTV Camera License per the following and per State of Florida Approved Products List:
Universal device licenses(0879-020)
Ordering Logic Number:
CCTO 1791
Fiber Patch Yellow Cord/Cables,LC/ST/3M 0S2,Duplex,w/twist connector for Axis Camera; Model:
LCSTDUPSM-3M
Ordering Logic Number:TO 1791
22
CCTO 1792
Fiber Patch Yellow Cord/Cables,LC/SC/3M 0S2,Duplex,w/Clip connector for Axis Camera;Model:
LCSCDUPSM-3M
Ordering Logic Number:TO 1792
Switches
CCTO 3300
Network Devices,per the following and per State of Florida Approved Products List:Rugged,Modular Base,8
Copper plus 2 Fiber Ports,Cisco IE3300-8T2S-E 10 Port Ethernet Switch
Ordering Number Logic:
Cisco IE3300-8T2S-E,or approved equivalent
CCTO 3301
Network Devices,per the following and per State of Florida Approved Products List:Proline Cisco GLC-LX-SM-
RGD,Fiber SSP
Ordering Number Logic:
TO 3301,or approved equivalent
CCTO 3302
Network Devices,per the following and per State of Florida Approved Products List:Rugged,8 copper,Cisco IEM
3300-8T 8 Port Ethernet Expansion
Ordering Number Logic:
Cisco IEM 3300-8T,or approved equivalent
CCTO 3303
Network Devices,per the following and per State of Florida Approved Products List: 50 Watts. 100-240VAC,
Cisco PWR-IE50W-AC Power Supply
Ordering Number Logic:
Cisco PWR-IE50W-AC,or approved equivalent
CCTO 3304
Network Devices,per the following and per State of Florida Approved Products List: Cisco Optical Transceiver
SMF, 1550nm,80km,LC,DOM, IOG,Cisco SFP-10G-ZR-S SFP
Ordering Number Logic:
Cisco SFP-I OG-ZR-S,or approved equivalent
CCTO 1759
Battery Meter per the following and per State of Florida Approved Products List:Tycon system
TP-Battmeter-24 12V/24V Battery Meter
Ordering Number Logic:TO 1759 Tycon system TP-Battmeter-24
CCTO 2251
Network Devices-Wireless WIFI Router
Ordering Number Logic:TO 2251:Teltonika,Model Number:RUT240 or approved equivalent
23
Exhibit B
Fee Schedule
following this page (pages 1 through 9 )
Page 16 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]
INVITATION TO BID (ITB)#24-8208
"TRAFFIC SIGNAL COMPONENTS& HARDWARE"
EXHIBIT B—FEE SCHEDULE
PRIMARY AWARDED
SECONDARY AWARDED
NOT AWARDED
TEMPLE,INC.
Line Equivalent with
TO
Item Number Description QTY Unit Price APL (if applicable)
Number and part number
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:SOLID Three(3)Section
Horizontal configuration per MUTCD Part 4, S 563.00
1 TO 1502 Figure (B—Typical Arrangements) 1
Ordering Number Logic: Primary Award
TO 1502:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:ARROW Three(3)Section
Horizontal configuration per MUTCD Part 4, $ 578.00
2 TO 1506 Figure 4D-10(B—Typical Arrangements) 1
Ordering Number Logic: Primary Award
TO 1506:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:Four(4)Section Horizontal
configuration per MUTCD Part 4,Figure 4D-12 $ 704.00
3 TO 1509 (B—Typical Arrangements) 1
Ordering Number Logic: Primary Award
TO 1509:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
1
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:Five(5) Section Horizontal
configuration per MUTCD Part 4,Figure 4D-11 $ 916.00
4 TO 1510 (B—Typical Arrangements)Ordering Number
Logic: Primary Award
TO 1510:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:Four(4)Section Vertical
configuration per MUTCD Part 4,Figure 4D-12 $ 704.00
5 TO 1511 (B—Typical Arrangements)Ordering Number 1
Logic: Primary Award
TO 1511:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
Signal,Vehicle Traffic Control per the following
and per State of Florida Approved Products List:
Signal Head:Five(5) Section Vertical Cluster
configuration per MUTCD Part 4,Figure 4D-11 $ 916.00
6 TO 1512 (B—Typical Arrangements) 1
Ordering Number Logic: Primary Award
TO 1512:Mobotrex Traffic Signal housing or
approved equivalent&Dialight LED or
approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
Products List: Optical Unit:Light Emitting $ 48.00
7 TO Diode(LED) 12-inch Diameter,Solid Red. I
1513-R Ordering Number Logic: Primary Award
TO 1513-R: 12"Dialight LED Red Signal or
approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
Products List:Optical Unit: Light Emitting $ 53.00
8 TO Diode(LED) 12-inch Diameter,Solid Yellow. 1
1513-Y Ordering Number Logic: Primary Award
TO 1513-Y: 12"Dialight LED Yellow Signal or
approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
Products List: Optical Unit:Light Emitting c; 49.00
9 TO Diode(LED) 12-inch Diameter,Solid Green. 1
1513-G Ordering Number Logic: Primary Award
TO 1513-G: 12"Dialight LED Green Signal or
approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
TO Products List:Optical Unit:Light Emitting $ 56.00
l0 1513- Diode(LED) 12-inch Diameter,Arrow Red.
RA Ordering Number Logic: Primary Award
TO 1513-RA: 12"Dialight LED Arrow Red
Signal or approved equivalent
2
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
TO Products List: Optical Unit:Light Emitting $ 57.00
11 1513- Diode(LED) 12-inch Diameter,Arrow Yellow. 1
YA Ordering Number Logic: Primary Award
TO 1513-YA 12"Dialight LED Arrow Yellow
Signal or approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
TO Products List: Optical Unit:Light Emitting $ 56.00
12 1513- Diode(LED) 12-inch Diameter,Arrow Green. 1
GA Ordering Number Logic: Primary Award
TO 1513-GA 12"Dialight LED Arrow Green
Signal or approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following:
TO Optical Unit:Light Emitting Diode(LED) 12- $ 71.00
13 1513- inch Diameter,U-Turn Red.Ordering Number 1
RU Logic: Primary Award
TO 1513-RU: 12"Dialight LED U-Turn Red
Signal or approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following:
TO Optical Unit:Light Emitting Diode(LED) 12- $ 101.00
14 1513- inch Diameter,U-Turn Yellow.Ordering 1
YU Number Logic: Primary Award
TO 1513-YU: 12"Dialight LED U-Turn Yellow
Signal or approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following:
TO Optical Unit:Light Emitting Diode(LED) 12- $ 101.00
15 1513- inch Diameter,U-Turn Green.Ordering Number 1
GU Logic: Primary Award
TO 1513-GU: 12"Dialight LED U-Turn Green
Signal or approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
Products List: Optical Unit:Light Emitting
Diode(LED) 12-inch Diameter,Solid Red and
16 TO Solid Yellow. 1 81.00
1513-RF Operating Voltage: 10-30V DC optical unit. Secondary Award
Ordering Number Logic:
TO 1513-RF: 12"Dialight 10-30 V DC LED
Red Signal,Part Number:433-1210-005XL or
approved equivalent
Signal,Vehicle Traffic Control LED inserts per
the following and per State of Florida Approved
Products List: Optical Unit:Light Emitting
Diode(LED) 12-inch Diameter,Solid Red and
17 TO Solid Yellow. 97'00
1513-YF Operating Voltage: 10-30V DC optical unit. Secondary Award
Ordering Number Logic:
TO 1513-YF: 12"Dialight 10-30 V DC LED
Yellow Signal,Part Number:433-3230-905XL
or approved equivalent
3
Signal Visor,Vehicle Traffic Control per the
following and per State of Florida Approved
Products List: Signal Head 12"Tunnel Visor $ 29.00
18 TO 1532 Ordering Number Logic:
TO 1532:Mobotrex housing Visor or approved Secondary Award
equivalent
Back plates,Horizontal 1-Section Signal Head BPAR501ANLFL,650-
per the following and per State of Florida 002-003
Approved Products List:Louvered with 2"
19 TO 3002 Reflective 3M Tape 1 77.00
Fits Signal Head Brand:Eagle Signal Ordering Secondary Award
Number Logic:
TO 3002:Transportation Control Systems Part
No.BP-5001B-F or approved equivalent
Back plates,Horizontal 2-Section Signal Head BPAR502ANLFL,650-
per the following and per State of Florida 002-003
Approved Products List:Louvered with 2"
20 TO 3004 Reflective 3M Tape 1 79.00
Fits Signal Head Brand:Eagle Signal Ordering Primary Award
Number Logic:
TO 3004:Transportation Control Systems Part
No.BP-5002B-F or approved equivalent
Back plates,Horizontal 3-Section Signal Head BPAR503ANLFL,650-
per the following and per State of Florida 002-003
Approved Products List:Louvered with 2"
21 TO 3008 Reflective 3M Tape 1 104.00
Fits Signal Head Brand:Eagle Signal Ordering
Primary Award,
Number Logic:
TO 3008:Transportation Control Systems Part
No.BP-5003B-F or approved equivalent
Back plates,Horizontal 4-Section Signal Head BPAR504ANLFL,650-
per the following and per State of Florida 002-003
Approved Products List:Louvered with 2"
22 TO 3010 Reflective 3M Tape 1 129.00
Fits Signal Head Brand:Eagle Signal Ordering
Secondary Award
Number Logic:
TO 3010:Transportation Control Systems Part
No.BP-5004B-F or approved equivalent
Back plates,Horizontal 5-Section Signal Head BPAR505ANLFL,650-
per the following and per State of Florida 002-003
Approved Products List:Louvered with 2"
23 TO 3012 Reflective 3M Tape 1 158.00
Fits Signal Head Brand:Eagle Signal Ordering
Secondary Award
Number Logic:
TO 3012:Transportation Control Systems Part
No.BP-5005B-F or approved equivalent
Back plates,Vertical Cluster 5-Section Signal BPAR505HNL02FL,
Head per the following and per State of Florida 650-002-003
Approved Products List:Louvered with 2"
Reflective 3M Tape $ 226.00
24 TO 3014 Fits Signal Head Brand:Eagle Signal Cluster 1
Mast Arm Mount Secondary Award
Ordering Number Logic:
TO 3014:Transportation Control Systems Part
No.BP-5007B-F or approved equivalent
4
Back plates,Cluster 5-Section Signal Head per BPAR505HNL01FL,
the following and per State of Florida Approved 650-002-003
Products List:Louvered with 2"Reflective 3M
Tape $ 226.00
25 TO 3016 Fits Signal Head Brand:Eagle Signal Cluster
Span Wire Mount Secondary Award
Ordering Number Logic:
TO 3016:Transportation Control Systems Part
No.BP-5021B-F or approved equivalent
Signal,Pedestrian Traffic Control per the
following and per State of Florida Approved
Products List:Housing: 16"X 18"
Symbol:Full Hand&Full Person with egg crate
26 TO 1540 type visor Ordering Number Logic: 1 $ 330.00
TO 1540:Mobotrex housing Model
SG7SZ20C3FFF10-21 or approved equivalent&
Dialight Corporation,Model 430-6479-805XF or
approved equivalent
Signal,Pedestrian Traffic Control Module per
the following and per State of Florida Approved
Products List: Optical Unit:LED Single module
27 TO 1542 Symbol:Full Hand&Full Person.Ordering 1 $ 151.00
Number Logic:TO 1542:Dialight Corporation,
Model 430-6479-805XF or approved equivalent
Mast arm Astro-Brac Stellar clamp Mount
Assembly per the following and per State of
Florida Approved Products List:
Mast Arm Signal Hanger
28 TO Number of Signal Head Sections:3 Cable 1 $ 246.00
2922g Length: 120 inches
Paint No Color
Ordering Number Logic:TO 2922g Pelco
Products,Inc.,Model Number:SP-1006-FL-3-
120-PNC or approved equivalent
Mast arm Astro-Brac Stellar clamp Mount
Assembly per the following and per State of
Florida Approved Products List:
Mast Arm Signal Hanger
29 TO Number of Signal Head Sections:4 Cable I $ 255.00
2922h Length: 120 inches
Paint No Color
Ordering Number Logic:TO#2922h:Pelco
Products,Inc.,Model Number: SP-1006-FL-4-
120-PNC or approved equivalent
Mast arm Astro-Brac Stellar clamp Mount
Assembly per the following and per State of
Florida Approved Products List:
Mast Arm Signal Hanger $ 269.00
30 TO Number of Signal Head Sections:5 Cable
2922i Length: 120 inches Secondary Award
Paint No Color
Ordering Number Logic:TO 2922i:Pelco
Products,Inc.,Model Number:SP-1006-FL-5-
120-PNC or approved equivalent
5
Mast arm Astro-Brac Stellar clamp Mount
Assembly per the following and per State of
Florida Approved Products List: $ 155.00
31 TO Mast Arm Signal Hanger Cable Length: 120 1
2908a inches Paint No Color Secondary Award
Ordering Number Logic:TO 2908a:Pelco
Products,Inc.Model Number:SP-1079-FL-120-
PNC or approved equivalent
Mast arm Astro-Brac Steller Articulating clamp
Mount Assembly per the following and per State
of Florida Approved Products List:
Bracket Articulated Mounting.Cable Length:96 $ 161.00
TO
32 2928a inches 1
Paint No Color Primary Award
Ordering Number Logic:
TO 2928a Pelco Products,Inc.,Part No.SP-
1118-FL-96-PNC or approved equivalent
Mast arm Astro-Brac Steller Articulating clamp
Mount Assembly per the following and per State
of Florida Approved Products List:
Bracket Articulated Mounting.Cable Length:96 $ 164.00
33 2928b inches 1
Paint No Color Primary Award
Ordering Number Logic:
TO 2928a Pelco Products,Inc.,Part No.SP-
1118-FL-120-PNC or approved equivalent
Hanger Assembly,Tri-Stud per the following
and per State of Florida Approved Products List:
Cast Aluminum Upper and Lower Hanger $ 143.00
34 TO 2926 Paint No Color 1
Ordering Number Logic: Secondary Award
TO 2926:Pelco Products,Inc.,Part No.SP-
1050-FL-PNC or approved equivalent
Disconnect for Single Door,per the following
and per State of Florida Approved Products List:
Color:Cat Alum w/SS Hardware Non-Thread
35 TO 2924 top&Tri-Stud 1 $
Ordering Number Logic:TO 2924:Pelco
Products Inc.,Part No.:SE-1087-FL-2 or
approved equivalent
Bracket Assembly,Tri-Stud Upper Arm per the
following and per State of Florida Approved
Products List:Direction: 2-Way $ 106.00
36 TO 2940 Color:Flat Black Ordering Number Logic: 1
TO 2940:Pelco Products,Inc.,Part No.SP- Secondary Award
1026-FL-P34 or approved equivalent
Bracket Assembly,Single Stud Lower Arm per
the following and per State of Florida Approved
Products List.Direction: 2-Way
37 TO 2942 Color: Flat Black Ordering Number Logic: 1 44.00
TO 2942:Pelco Products,Inc.Part No.SP-1027- Primary Award
FL-P34 or approved equivalent
6
Pedestrian Bracket Assemblies,Aluminum side
of pole,Tri-Stud per the following and per State
of Florida Approved Products List: $ 55.00
38 TO 1602 Tri-Stud Upper Arm Assembly Color:Flat Black
Ordering Number Logic: Secondary Award
TO 1602:Pelco Products Inc.Part Number:SP-
1011-FL-P34 or approved equivalent
Pedestrian Bracket Assemblies,Aluminum side
of pole,Tri-Stud per the following and per State
of Florida Approved Products List: $ 60.00
39 TO 1604 Tri-Stud Lower Arm Assembly Color:Flat Black
Ordering Number Logic: Secondary Award
TO 1604:Pelco Products Inc.Part Number:SP-
1012-FL-P34 or approved equivalent
Closure Assembly,Vehicle Traffic Control SP-1077-FL-P02
Signal per the following and per State of Florida
Approved Products List: Signal head closure kit
40 TO 1518 Ordering Number Logic: 1 $ 18.00
TO 1518:Pelco Products,Inc. SE-3054-P02 or
approved equivalent
Post Top Adapter(Slip Fitter),Pedestrian Traffic
Control Signal per the following and per State of
Florida Approved Products List $ 72.00
Aluminum Tri-Stud Adapter for use with 4-1/2
41 TO 2952 1
inch OD Aluminum Pole Paint No Color
Ordering Number Logic: Secondary Award
TO 2952:Pelco Products,Inc.Part No.,EC-
3004-T-PNC or approved equivalent
Pole,Spun Aluminum,Schedule 40,per the
following and per State of Florida Approved
Products List: Size: 4.5 inch OD
42 TO Length:7' Paint No Color 1 $
2954c Ordering Number Logic:
TO 2954c:Pelco Products,Inc.Part No.,PB-
5100-7-PNC or approved equivalent
Sign Mountings Anchor bolt per the following N/A
and per State of Florida Approved Products List:
Anchor Bolt Sets
43 TO 2959 Exterior:Galvanized Includes 4 each:Bolts, 1 $ 122.00
Washers and Nuts Ordering Number Logic:TO
2959:Pelco Products Inc.,Part Number:PB-
5543-GL
Pedestal Base,Alum with Alum Door, 13
5/8"x13 5/8"x15",Threaded for 4.5"OD Alum
Pole per State of Florida Approved Products $ 228.00
44 TO 2960 List: 1
Ordering Number Logic: Secondary Award
TO 2960:Pelco Model SP-1116-FL-GL-PNC or
approved equivalent
7
Collar,Reinforcing for Square Pedestal Base,
4.5"OD Alum Pole,Stainless Steel Fasteners per
State of Florida Approved Products List: $ 91.00
45 TO 2962 Ordering Number Logic: 1
TO 2962:Pelco Model PB-5325 or approved primary Award
equivalent
Sign Hanger Assembly,Mast Arm,Free
Swinging,Mini Brac Mount,84"Cable,
Stainless Steel Hardware per State of Florida $ 421.00
46 TO Approved Products List: 1
2981b Ordering Number Logic:
Pelco Products Inc.Part No. SP-1072-FL-84- Primary Award
PNC or approved equivalent;Material:
Aluminum,length: 84 inches
Traffic Signal Hardware,Components,Pipe
Fittings, 1 1/2"Grommet,Neoprene w/ $ 8.00
47 TO 2984 Diaphragm for Disconnect Cable Openings 1
Pelco Products Inc.Part No.SE-0449-PNC or Secondary Award
approved equivalent;
Traffic Signal Hardware,Components,Pipe
Fittings per the following and per State of
Florida Approved Products List: $ 5.00
48 TO 2986 Double Serrated Lock ring,Aluminum 1
Ordering Number Logic: Secondary Award
TO 2986:Pelco Products Inc.Part No.SE-0451-
PNC or approved equivalent
Hardware,Components,Extension(Extender),
Alum,72"
Ordering Number Logic: $ 43.00
49 TO 2994 TO 2994:Pelco Products Inc.,Part Number:SE- 1
0507-72 or approved equivalent Secondary Award
Pole Cap,Acorn Type,Alum,4 1/2"OD Pole,
Stainless Steel Fasteners, No Paint
Ordering Number Logic:
50 TO 3030 TO 3030:Pelco Model:PB-5401 or approved I $ 23.00
equivalent
NOT AWARDED Utility Pole Hardware, 7/8" NIA
lb,7/8"Rod Diameter,Rod Length 120"(10ft),
5-4 TO 3126 End Fittings Clevis w/Roller Clevis Clevis 2
List Ordering Number Logic:
TO 3126:Hubbell Power Systems Model:
GS36120CC2
Pushbutton,Pedestrian Detector(Momentary
LED Model)per the following and per State of
Florida Approved Products List: $ 104.00
52 TO 1806 Ordering Number Logic: Ordering 1
Number Logic: Primary Award
TO 1806:Polara Bulldog III BDL3-B or
approved equivalent
8
Pushbutton,Pedestrian Detector,Aluminum BDPM3-B
Push Button Cup,per the following and per State
of Florida Approved Products List: $ 22.00
Aluminum cup for mounting the BullDog
53 TO 1808 Pedestrian Detector.Color:Black Primary Award
Ordering Number Logic:
TO 1808:Polara Aluminum Push Button Cup
APBC2-B or approved equivalent
Pushbutton,Pedestrian Detector,Audible/Tactile iNS2 push button sta,
Pedestrian Detector with Pedestrian Station 665-001-012
Monitor,per the following and per State of
Florida Approved Products List:
Push Button:ADA Compliant,raised tactile $ 582.00
54 TO 1812 arrow on button,solid state switch rated to 20 1
million actuations minimum. Primary Award
Color:Black
Ordering Number Logic:
TO 1812:Polara 2 Wire Navigator Push Button
Station EN23TN1-B or approved equivalent
Detector,Dual Channel Rack Mount Loop per
the following and per State of Florida Approved
Products List: $ 152.00
55 TO 1704 Ordering Number Logic:TO 1704:Eberle
Design Inc.,Part No.LMD622 sesries or Primary Award
approved equivalent
Controller,Traffic NEMA TS2,Type 2 per the
following and per State of Florida Approved
Products List: Q-Free XN-2 NEMA TS2,Type 2
56 TO 2010 Ordering Number Logic:TO 2010: 1 $ -
Q-Free XN-2 or approved equivalent
Cabinet,Traffic Signal Controller Assembly per Model TF5116TFL02,
the following and per State of Florida Approved 676-023-006
Products List:NEMA Standard TS2 Type 1
size Type 6 with:One(1)detector rack with one
(1)BIU,8 Two Channel Detector Cards,and one $ 24,547.00
(1)GTT Opticom Phase Selector Card
57 TO 2102 1
One(1)detector rack with one(1)BIU,8 Two Secondary Award
Channel Detector Cards; One(1)cabinet power
supply,TS-2;Sixteen(16)NEMA load switches
One(1)NEMA flasher;Six (1)NEMA flash
transfer relays
Ordering Number Logic:TO 2102
Cabinet,Traffic Signal Controller Assembly
Power Connector Adapter Cable from TS2,Type
1 to TS2,Type 2 Traffic Controller.Ordering $ 130.00
58 TO 2105 Number Logic: 1
Temple,Inc Part Number:ABW 12027P001 or Primary Award
approved Equivalent
APL Number:676-034-001
9
Cabinet Power Supply,TS-2 per the following
and per State of Florida Approved Products List:
Ordering Number Logic: $ 560.00
59 TO TO 2206A:Eberle Design Inc.,Part No.EDI- 1
2206a PS250 or approved equivalent Secondary Award
SmartMonitor Program Card,Malfunction
Management Unit(MMU2)per the following
and per State of Florida Approved Products
60 TO 2223 List:Compatible with MMU2-I6LE(ip)s 1 $ 1,288.00
Ordering Number Logic:TO 2223:Eberle
Design Inc.,MMU2-16LE(ip)SmartMonitor
Program Card or approved equivalent
NEMA Load Switch per the following and per
State of Florida Approved Products List:
Ordering Number Logic:
61 TO 2224 TO 2224:Power Distribution&Control,Inc., 1 25.00
Part No.SSS-86-3 or approved equivalent Primary Award
NEMA Flasher Load Switch Type 3 per the
following and per State of Florida Approved
Products List:Ordering Number Logic:
62 TO 2226 TO 2226:EDI 810-Power Distribution& 1 $ 25.00
Control,Inc.,Part No.SSF-86-3 or approved Primary Award
equivalent
Flasher Relay AI DC per the following and per
State of Florida Approved Products List:
Ordering Number Logic: $ 41.00
63 TO 2227 TO 2227:AI 900-010 or approved equivalent 1
Primary Award
Bus Interface Unit(BIU)per the following and
per State of Florida Approved Products List:
Ordering Number Logic:
64 TO 2228 TO 2228:Eberle Design Inc.,Model:BIU-700 1 $ 339.00
or approved equivalent
4 11/16 inch Square Axial Fan per the following: Orion Fans,PN 0A4715-
Fan Voltage: 115 VAC 12TB
Ordering Number Logic: $ 25.00
65 TO 2110 TO 2110:Dayton Part Number 2RTK6 or 1
approved equivalent Primary Award
10
Low Voltage Surge Protector,Isolated Pedestrian Hesco,RLS.PN
Circuit Protector per the following and per State HE642C-030C
of Florida Approved Products List:
Peak Surge Current: 10 kA(8 x 20 µs)Voltage $ 29.00
66 TO 2112 Clamp:30 volts;dual pair(4 wire)
Ordering Number Logic: Primary Award
CCTO 2112 Asco Power Technologies,Surge
Protector,Model: 175D030S1OKLPCNO(Edco
PC642C-030)or approved equivalent
APL Number:676-004-010
Standard Socket Card Edge Terminal Connector, Hesco,RLS,PN
Plug-in style socket for Surge suppressors/per the PCB1B10A
following and per State of Florida Approved
Products List:
Peak Surge Current: 10 kA(8 x 20 µs);Voltage $ 13.00
67 211112a Clamp:30 volts; Ordering Number 1
Logic: Primary Award
CCTO 2112a Asco Power Technologies,Surge
Protector,Model:(EDCO PCB1B-WKEY)or
approved equivalent
APL Number:676-004-010
10 Circuit SDLC Hub per the following and per
State of Florida Approved Products List:
Compatible with NEMA TS2-Type 1 controller
Assembly;Number of SDLC communication
68 TO 2113 ports: 10; 1 $ -
Ordering Number Logic:
Transportation Control Systems Inc.,TS2 Traffic
Signal Cabinet, 10 circuit,SDLC Hub or
approved equivalent APL Number:676-034-003
Flash Transfer Relay per the following and per Struthers&Dunn,PN
State of Florida Approved Products List:Pole W21ACPX2,678-005-
Configuration:DPDT $ 28•00 009
f>9 TO 2302 Coil Input Voltage: 110/120 VAC 50/60 Hz 1
Contact Load Rating:20 Amps at 120 VAC Primary Award
Ordering Number Logic:
TO 2302:Deltrol Controls,Model:295 or
approved equivalent
Filter,Traffic Cabinet AC Power Line per the Flesco,RLS,PN LF6OX
following and per State of Florida Approved
Products List: $ 30.00
70 TO 2118 120VAC,60A,50/60Hz;UL 1283 Compliant 1
Ordering Number Logic:Asco Power Primary Award
Technologies,Model:250120NF060AN3N0
(Edco INXT120NL000-1)or approved
equivalent
NEMA TS2 Type-1 Load Bay circuit L-board
per the following and per State of Florida
Approved Products List:Manufacturer:Eagle $ 169.00
71 TO 2202 Ordering Number Logic:
TO 2202:Mobotrex,Part Number: Primary Award
ACP11957P001 or approved equivalent
11
Rack TS2,Cabinet Detector per the following
and per State of Florida Approved Products List:
Housing and Circuitry for one(1)BIU and 8
Two Channel Detector Cards;37 Pin Connector
attached to the printed circuit board for
designated inputs/outputs $ 301.00
72 TO 2208 Dimensions: 14.6"W x 5.4"H x 7.5"D
Ordering Number Logic: Primary Award
Mobotrex,Part Number:CDR100 or approved
equivalent
APL Number:676-028-001
Rack TS2,Cabinet Detector per the following
and per State of Florida Approved Products List:
Rack TS2,Cabinet Detector per the following
and per State of Florida Approved Products List:
Housing and Circuitry for one(1)BIU and 4
Two Channel Detector Cards.;37 Pin Connector
attached to the printed circuit board for $ 294.00
73 TO 2210 designated inputs/outputs 1
Dimensions:9.8"W x 5.9"H x 7.1"D Primary Award
Ordering Number Logic:
Mobotrex,Part Number:CDR101 or approved
equivalent
APL Number:676-028-001
Rack TS2,Eagle Cabinet Detector per the
following and per State of Florida Approved
Products List:
Housing and Circuitry for one(1)BIU,8 Two S 712.00
74 TO 2212 Channel Detector Cards,and one(1)GTT 1
Opticom Phase Selector Card. Primary Award
Ordering Number Logic:
TO 2212:Mobotrex(Eagle),Part Number:
AAD12047P001 or approved equivalent
Rack TS2,TCS Cabinet Detector per the
following and per State of Florida Approved
Products List:
Housing and Circuitry for one(1)BIU,8 Two
75 TO 2214 Channel Detector Cards,and one(1)GTT 1 S
Opticom Phase Selector Card.
Ordering Number Logic:
TO 2214:TCS Part Number TCS CRBIU8-5;
TCS-413: or approved equivalent
Inductive Loop Panel,TS2,Cabinet Detector per
the following and per State of Florida Approved
Products List:PCB for 16 channels(1-16)of $ 228.00
76 TO 2111 inductive loop detection. 1
PCB for 4 channels of GTT Infrared Opticom Primary Award
Detection.Ordering Number Logic:TO 2111:
Mobotrex,Part Number:ACP14829P002 or
approved equivalent
12
NEMA TS2 Type-1 Load Bay circuit board per
the following and per State of Florida Approved
Products List:Manufacturer:Transportation
Control Systems Inc.
77 TO 2201 Printed Circuit Board(PCB)for Traffic Signal 1 S
Cabinet Loadbay BIU 1.Ordering Number
Logic:
TO 2201:Transportation Control Systems Inc.,
PCB for Loadbay BIU 1,or approved equivalent
CCTV Camera Ethernet Extender components Model TF4001F-FL
per the following and per State of Florida wireed Type 1 cabinet,
Approved Products List:POE(power over 676-011-012
78 TO 2362 ethernet)for CAT 5e or Cat6 1 $ I,032 00
57V 800mA power supply for POE Ordering Equivalent not approved
Number Logic:
TO 2362:Veracity USA,Inc.,Part Number:
VPSU-57V-800 or approved equivalent
Ethernet Extender,Outreach Lite
Ordering Number Logic:TO 2374
24 Ethernet Extender,Outreach Lite per State of
79 TO 2374 Florida Approved Products List:Veracity VOR- 1 S
ORL-XT or approved equivalent
Ethernet Extender,Outreach MAX
Ordering Number Logic:TO 2375
24 Ethernet Extender,Outreach MAX per State
80 TO 2375 of Florida Approved Products List:Veracity 1 S
VOR-ORM-XT or approved equivalent
Ethernet Extender,Camera Ethernet Extender
components per the State of Florida Approved
Products List:
81 TO 2376 POE(Power over Ethernet)Network injector for 1 $
CAT 5e or Cat6 Veracity USA,Inc.,
Outsource,Part Number:VOR-OSP or approved
equivalent
Ethernet Extender Set;for Cate 5e of 6
Model Veracity#VLS-1N-L or approved
equivalent
82 TO 2378 1 set includes: 1 S
(1)long range ethernet 6100-FV-VLSINL-
LONGSPAN LITE POE
(1) 12V DC Power supply 6100-VV-
VPSU12VUS-POWER SUPPLY
Reducer Bushing, 1-1/2"NPT x 3/4"NPT,
Galvanized Iron per the following:Material:
Galvanized Iron. $ 8.00
83 TO 2927 Ordering Number Logic: 1
TO 2927:Pelco Products Inc.,Part Number:SE- Secondary Award
0471-GLV or approved equivalent
13
School Zone Flasher,Solar Powered,Single
Beacon per the following and per State of Florida
Approved Products List:
Operation: School Zone Power Source: S 4,167.00
84 TO 1514 Solar/Battery Number of Beacons:Single
Beacon Color:Yellow Primary Award
TO 1514:Carmanah Technologies Corp.,Model:
R829G with single beacon or approved
equivalent
School Zone Flasher,Solar Powered,Dual
Beacon per the following and per State of Florida
Approved Products List:Operation:School Zone
Power Source: Solar/Battery Number of S 4,890.00
85 TO 1516 Beacons:Dual Beacon Color:Yellow Ordering 1
Number Logic: Primary Award
TO 1516:Carmanah Technologies Corp.,Model:
R829G with dual vertical beacons or approved
equivalent
Flashing Beacon,Solar Powered,Single Beacon Carmanah R247-G,700-
per the following and per State of Florida 026-013
Approved Products List:Operation:24-7
Flashing
Power Source: Solar/Battery $ 3,497,00
86 TO 1519 Type of Beacon: Single 12 in(305 mm)diameter 1
yellow LED beacon.Beacon Mounting:4.0" Primary Award
4.5"Diameter Round Pole Mount
Ordering Number Logic:
TO 1519:Carmanah Technologies Corp.,Model:
R247-E with Yellow beacon or approved
equivalent
Midblock Crosswalk Enhancement Assemblies— Carmanah R920-F,654-
Rectangular Rapid Flashing Beacon Assembly 001-012
(RRFB) per the following and per State of
Florida Approved Products List:
Power Source: Solar/Battery. S 4,700.00
87 TO 1523 Solar Panel:30 W high-efficiency photovoltaic 1
solar panel.Light Bar Configuration: Single. Primary Award
Ordering Number Logic:
TO 1523:Carmanah Technologies Corp.,Single
Light Bar Configuration,Model Number:R920
or approved equivalent
Midblock Crosswalk Enhancement Assemblies— Carmanah R920-F,654-
Rectangular Rapid Flashing Beacon Assembly 001-012
(RRFB) per the following and per State of
Florida Approved Products List:
Power Source: Solar/Battery. $ 5,478.00
88 TO Solar Panel:30 W high-efficiency photovoltaic 1
1523a solar panel.Light Bar Configuration:Dual Light Primary Award
Bars
Ordering Number Logic:
TO 1523a:Carmanah Technologies Corp.,Dual
Light Bar Configuration,Model Number:R920
or approved equivalent
14
Electronic Display Sign(EDS)—Electronic
Speed Feedback Sign(ESFS)per the following
and per State of Florida Approved Products List:
Operation:School Zone Power Source:
Solar/Battery
Display Message LED digits: 15 inches. 8,192.00
Includes one Dialight 12 inch yellow LED
89 TO 3160 beacon(MUTCD Compliant).Ordering Number I Primary Award
Logic:
TO 3160:Carmanah Technologies Corp.,
Information Display Company,One Dialight 12
inch yellow LED
beacon,Model Number:SpeedCheck-15-SZ-S-
B1 or approved equivalent
Cellular Programmable Temple Inc.FCU-500-
071 Time Switch System per the following and
per State of Florida Approved Products List: S 2,519.00
90 TO 2205 Includes 5 year Cellular connectivity plan 1
Ordering Number Logic: Primary Award
TO 2205:Includes 5 year Cellular connectivity
plan.Temple Inc.,Part Number FCU-500-071 or
approved equivalent
Type 1 Wired Flasher Cabinet Assembly per the
following and per State of Florida Approved
Products List:Operation:School Zone S 3,007.00
91 TO 2106 Power Source: Solar/Battery Mounting option 1
for flat surface.Ordering Number Logic: Primary Award
TO 2106:Temple Inc.,Part Number:TF4001 F-
FL-DC with Mounting option for flat surface or
approved equivalent
NOT AWARDED D ll Box(Box). r the
followingd p r State of Florida Approved
.
9-2 TO 2702 Inside Dimensions:Width: 13 Inches,Length: 21 } S
Inches,Depth: 12 Inches.Model:PG 1321 BA 12
aialent
NOT AWARDED Pull Box(Cover)per the
Products List:
s13 TO 2701 Heavy Duty w/2 Bolts,Rated:20,000 lb. k $
Ordering Logic:TO 2704
Manufacturer's1 N Il b t a each
SIGNAL
NOT AWARDED Heavy Duty w/2 Bolts,Ratcd:
�1 20,000 lb.(2"Thick x 13"W x 21"L)
CCTV Manufacturer'sI shall be st.,mpe
94 6613 a 4- S
"ROADWAY LIG _ . - - .b 's:.,:
CCTO 6615
NOT AWARDED Heavy Duty w/2 Bolts,Rated:
20,000 lb.(1 3/4"Thick x 11"W x 18"L)
9-5 4-4- S
66
"ROADWAY LIGHTING".Ordering Logic:
CCTO 6622
15
NOT AWARDED Heavy Duty w/2 Bolts,Rated:
CCTO 20,000 lb.(3/4"Thick x 11"W x 18"L)
96 6623 Manufacturer's logo shall be stamped on each + S
pull box cover along with the words
"ROADWAY LIGHTING".
NOT AWARDED
4-
followingnd r State of Florida Approved
Products List: Heavy Duty,Rated: 20,000 lb.
9-7 TO 2706 Model:PG1730BA12 Inside Dimensions: S
Width: 17 Inches,Length:30 Inches,Depth: 12
Inches. Ordering Logic TO
2796
NOT AWARDED Heavy Duty w/2 Bolts,Rated:
20,000 lb.(2"Thick x 17"W x 30"L)
9-8 TO 2708 Manufacturer's logo shall be stamped on each 4- $
pull box cover along with the words"TRAP-PIG
SIGNAL".Ordering Logic TO 2708
NOT AWARDED Pull Box x)per the following
and por Stato of Florida Approved Products List:
Material: Polymer Concrete; Heavy Duty;Rated:
20,000 lb.;Open Bottom
s39 TO 2710 Inside Dimensions:Width:21 Inches,Length: 36 $
Inches,Depth:21 Inches.
Ordering Number Logic:
St l l n ite PG2 A 36B
equivelent
APL Number:635 001 012
NOT AWARDED Pull Box(Cover)per the
Products List:
Bolts; Rated:20,000 lb.Heavy Duty w/2 Bolts,
+00 TO 2712 Rated:20,000 lb.;Fits Pull Box 24-Inches, 4
Length:36 Inches,Depth:21 Inches
COMMUNICATIONS". Strongwcll Quazitc
PG2436HA or approved equivalent;APL
Number:635 001 012
NOT AWARDED Pull Box(Cover)por the
Products List:
Material:Polymer Concrete;Heavy Duty w/2
101 TO 2711 Bolts; Rated:20,000 lb.Hcavy Duty w/2 Bolts, 4- $
Rated:20,000 lb.21 X36X 18
M f t shall be st ea a ch
SIGNAL".Ordering Logic 2714
Utility Pole Hardware per the following: 1
7/8"Fiberglass Insulator Minimum Strength(lb)
-36,000
102 TO 3114 7/8"Rod Diameter,Rod Length 120"(10ft),End
Fittings-Clevis w/Roller-Clevis-Clevis-2 Roller
Ordering Number Logic:TO 3114
16
NOT AWARDED Cable,3/8 inch Utilities 444
Grade Steel Strand per the following:
103 TO 3120 Required minimum breaking strength: 11,500 4- $
pounds. 1000 ft spool length Ordering Logic
TO 3120
Traffic Signal Cable,IMSA 50-2,Stranded, N/A
AWG 14,2 Conductors per the following:
104 TO 1702 IMSA Specification:50-2 Cable Length:5000 ft 1 S
Spool Ordering Logic TO
1702
5 Conductor:Traffic Signal Cable, IMSA 19-1, N/A
Stranded,AWG 14 per the following:IMSA
105 TO 2602 Specification: 19-1 1 $
Cable Length:2000 ft.Spool
Orderding Logic:TO 2602
7 Conductor:Traffic Signal Cable, IMSA 19-1, N/A
Stranded,AWG 14 per the following:IMSA
106 TO Specification: 19-1 1 $
2602a Cable Length:2000 ft.Spool
Orderding Logic:TO 2602a
9 Conductor:Traffic Signal Cable, IMSA 19-1, 1 N/A
Stranded,AWG 14 per the following:IMSA
107 TO Specification: 19-1 $
2602b Cable Length:2000 ft.Spool
Orderding Logic:TO 2602b
12 Conductor:Traffic Signal Cable,IMSA 19-1, 1 N/A
Stranded,AWG 14 per the following:IMSA
108 2602c Specification: 19-1 $
Cable Length:2000 ft.Spool
Orderding Logic:TO 2602c
16 Conductor:Traffic Signal Cable,IMSA 19-1, 1 N/A
Stranded,AWG 14 per the following:IMSA
109 TO Specification: 19-1 $
2602e Cable Length:2000 ft.Spool
Orderding Logic:TO 2602e
NOT AWARDED r d r te. b nn n Fi xed
11 d i' 1200/2IOVAC p r-the
fellewingSpaeresi-6 S
-1-1-0 TO 2801 Ordering Logic:TO 2801-
120/210VAC
CCTV Camera per the following and per State
of Florida Approved Products List:
PTZ Camera, 1080p,40x optical zoom,Axis
111 TO 2390 AXISQ6075-E 1 $
Ordering Number Logic:TO 2390
Axis AXISQ6075-E,or approved equivalent
CCTV Connector per the following and per State
of Florida Approved Products List:
Camera Pendant Mount Kit T94A01d
112 TO 2391 Ordering Logic Number:TO 2391 1 $
AXIS-Q6075-E Camera Pendant Mount Kit
17
CCTV Connector per the following and per State
of Florida Approved Products List:
RJ45 push pull plug connector kit 5700-371
113 TO 2395 Ordering Logic Number:TO 2395 6100-AXIS- 1 $
RJ45-OUT
CCTV Camera Power Supply per the following
and per State of Florida Approved Products List:
Single port High PoE midspan,60 W.Compliant
114 TO 2393 with IEEE 802.3at and 802.3af I $
Ordering Number Logic:TO 2393
Axis T8134 60W Midspan Power Supply 5900-
334,or approved equivalent
NOT AWARDED AXIS Sky Bracket Mount N
Cable per State of Florida Approved Products
44� TO List: } $
2908c Ordering Logic Number:TO
2908c
Cable 120"; Model 6100 AXIS
CCTV Camera License per the following and per N/A
State of Florida Approved Products List:
Core device licenses(0879-010)for Axis devices
116 TO 2396 and 2N intercoms 1 $
Ordering Logic Number:
Core device licenses(0879-010)for Axis devices
and 2N intercoms
CCTV Camera License per the following and per N/A
State of Florida Approved Products List:
Universal device licenses(0879-020)
117 TO 2397 Ordering Logic Number: 1 S
Universal device licenses(0879-020)
NOT AWARDED Fiber Patch Yellow N
-1--1-8 TO 1791 e t _f n..: _ 4- $
Ordering Logic Number:TO 1791
LCSTDUPSM 3M;
NOT AWARDED Fiber Patch Yellow
r aim bt L Ci8C 3M nee Duple /eliip
1-19 TO 1792 connectors for Axis Camera 4- $
Ordering Logic Number:TO 1792
LCSCDUPSM 3M;
NOT AWARDED-Netwer-k-DeN4evesr per--the
Products List:
120 TO 3300 Rugged,Modular Base, 8 Copper plus 2 Fiber } S
Ports,Cisco 1E3300 8T2S E 10 Port Ethernet
Ordering Number Logic:
C IL'3300 8T2S c ed ate
18
NOT AWARDED Network Devices,per the
following and per State of Florida Approved
Products List:
-1-24- TO 3301 Prolinc Cisco GLC LX SM RGD,Fiber SSP 4 $
Ordering Number Logic:
TO 3301,or approved equivalent
NOT AWARDED Network Devices,per the
following and per State of Florida Approved
Products List:
122 TO 3302 Rugged,8 copper,Cisco IEM 3300 8T 8 Port 1. $
Ethernet Expansion
Ordering Number Logic:
Cisco IEM 3300 8T,or approved equivalent
NOT AWARDED Network Devices,per tho
following and per State of Florida Approved
Products List:
123 TO 3303 `" tt 100 2IOVAC Cisco PW keno nC } $
Pewver-Supply
Ordering Number Logic:
Cisco PWR IE50W AC,or approved equivalent
NOT AWARDED Network Devices,per the
following and per State of Florida Approved
Products List: Cisco Optical Transceiver
124 TO 3304 SMF, 1550nm,80km,LC,DOM, 10G,Cisco } $
SFP 10G ZR S SFP
Ordering Number Logic:
Cisco SFP 10G ZR S,or approved equivalent
NOT AWARDED Battery Meter per the NIA
following and per State of Florida Approved
Products List:
125 TO 1759 } $
Battery Meter
Tycon system TP Battmeter 24
Network Devices- Wireless WIFI Router
Ordering Number Logic: TO 2251: Teltonika,
Model Number:RUT240 or approved equivalent
126 TO 2251 1 $
19
Other Exhibit/Attachment
Description:
❑ following this page (pages through )
❑■ this exhibit is not applicable
Page 17 of 17
Fixed Term Service Multi-Contractor Agreement
[2024_ver.1]