Agenda 12/12/2023 Item #16C 4 (Change Order No. 1 with U.S. Water Service Corp.)12/12/2023 EXECUTIVE SUMMARY Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Services Corporation for the Pump Station 121.02 Repair and Renovations project, to add stormwater improvements to the scope of work included in Work Directive No. 1 in the amount of $115,336.42, to extend the time of the project for an additional 120 days and authorize the Chairman to sign the attached change order. (PUD Project Number 70240) OBJECTIVE: To approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Services Corporation for the Pump Station 121.02 Repair and Renovations project, to add stormwater improvements to the scope of work included in Work Directive No. 1 in the amount of $115,336.42 and extending the project an additional 120 days. CONSIDERATIONS: Pump Station (PS) 121.02 is located within the Collier County right-of-way at 57 West Avenue, approximately 160 feet south of Bonita Beach Road. It receives wastewater flows via a gravity sewer and repumps wastewater flows from eleven other wastewater pump stations. PS 121.02 is a critical component of the wastewater infrastructure. It is approximately 46 years old and has reached the end of its useful life. On October 26, 2021 (Agenda Item 16.C.4), the Board approved the issuance of a Purchase Order to U.S. Water Services Corporation (“U.S. Water”) to repair and renovate wastewater pump station 121.02 in the amount of $561,270.71 (the “Project”). The Project material submittals were approved and ordered for fabrication. Based on the material delivery date confirmed by the manufacturer for the pumps and control panels, it was expected that construction would occur sometime after February 2023. During the November 11, 2021, wastewater PS 121.02 pre-construction meeting, staff noticed settlement of West Avenue adjacent to PS 121.02. Supplementary inspections conducted in early 2022 noted additional settlement. A service request was processed, and West Avenue repair work was completed in the March/April 20 22 timeframe. During a second pre-construction meeting on November 30, site investigations revealed additional settlement of West Avenue in the same area. The Collier County Road Maintenance Division staff investigated and discovered that an existing 18” stormwater culvert crossing beneath West Avenue directly adjacent to the Pump Station 121.02 site had failed and caused West Avenue roadway to settle. This scope of work for the Project, which includes the replacement of an old manhole adjacent to the roadway settlement, cannot be completed without replacing the portion of the stormwater system under West Avenue. To address this condition, a design for stormwater improvements was completed, and permits for construction modifications were approved. These changes are necessary to restore the area, ensure proper stormwater drainage, and facilitate planned improvements while also restoring West Avenue to its original condition. This Change Order seeks approval to authorize a change in the scope of work for t he U.S. Water purchase order, to add stormwater improvements to the scope of work. The additional work to be completed includes demolishing, removing, and disposing of existing stormwater system components in the vicinity of the Pump Station 121.02 site, furnishing and installing new stormwater system components per the plans, grading the site to allow proper drainage, and restoring impacted areas. The purpose of staff’s work directive is to authorize a change in the contract price and timeline to accommodate the stormwater system improvements added in the vicinity of the Pump Station 121.02 site. The County received a quote for the additional construction work from U.S. Water in the amount of $115,336.42, which the Engineer of Record (Johnson Engineering, Inc.) and County staff reviewed and found reasonable. Subject to approval of this Change Order, the new Purchase Order amount will be $676,607.13 (see below chart), which remains under the $750,000.00 threshold amount provided for in Agreement No. 19-7622 with U.S. Water. 16.C.4 Packet Pg. 1869 12/12/2023 Item Description Order Qty Unit Price Per Unit Net Value Project Number 00010 Task 1 PS Rehabilitation (NLS) 496,270.71 EA 1 496,270.71 70240.4.2 00020 Task 2 Allowance FPL Electrical Services (T&M) 5,000.00 EA 1 5,000.00 70240.4.2 00030 Task 3 Allowance Unforeseen (T&M) 60,000.00 EA 1 60,000.00 70240.4.2 00040 NEW Task 4 Stormwater Improvements (NLS) 115,336.42 EA 1 115,336.42 TOTAL 676,607.13 FISCAL IMPACT: The cost of the additional work will be paid by the Collier County Stormwater Maintenance Division. Funding is available within Stormwater Utility Fund (1005), within the Storm water Maintenance cost center 172929. A new lump sum line item will be added to PO 4500215169 to cover the stormwater improvements of $115,336.42. GROWTH MANAGEMENT IMPACT: This project meets current Growth Management Plan standards to ensure the adequacy and availability of viable public facilities and to remain in compliance with all regulatory programs. LEGAL CONSIDERATIONS: This item is approved as to form and legality and requires majority vote for Board approval. -SRT RECOMMENDATION: Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Services Corporation for the Pump Station 121.02 Repair an d Renovations project, to add stormwater improvements to the scope of work included in Work Directive No. 1 in the amount of $115,336.42, to extend the time of the project for an additional 120 days and authorize the Chairman to sign the attached change order. (PUD Project Number 70240) Prepared By: Zamira DelToro, CSM, Project Manager II, Public Utilities Department, Engineering and Project Management Division. ATTACHMENT(S) 1. 1.Project location and Timeline Exhibit Photos (PDF) 2. 2. PO 4500215169 US Water Services Corporation (PDF) 3. 3. 4500215169_CO#1_US Water Services Corporation Approved (PDF) 4. 4. WD#1 US Water Services Corporation (PDF) 16.C.4 Packet Pg. 1870 12/12/2023 COLLIER COUNTY Board of County Commissioners Item Number: 16.C.4 Doc ID: 27285 Item Summary: Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Services Corporation for the Pump Station 121.02 Repair and Renovations project, to add stormwater improvements to the scope of work included in Work Directive No. 1 in the amount of $11 5,336.42, to extend the time of the project for an additional 120 days, and authorize the Chairman to sign the attached change order. (PUD Project Number 70240) Meeting Date: 12/12/2023 Prepared by: Title: Project Manager – Engineering and Project Management Name: Zamira Deltoro 11/15/2023 5:22 PM Submitted by: Title: Director – Engineering and Project Management Name: Matthew McLean 11/15/2023 5:22 PM Approved By: Review: Engineering and Project Management Shon Fandrich Additional Reviewer Completed 11/16/2023 7:56 AM Engineering and Project Management Matthew McLean Additional Reviewer Completed 11/16/2023 9:50 AM Procurement Services Vanessa Miguel Level 1 Purchasing Gatekeeper Completed 11/16/2023 11:04 AM Road Maintenance Marshal Miller Additional Reviewer Completed 11/16/2023 11:10 AM Public Utilities Operations Support Joseph Bellone Additional Reviewer Completed 11/16/2023 1:28 PM Public Utilities Department Mary Linhard Level 1 Department Review Completed 11/17/2023 12:07 PM County Attorney's Office Scott Teach Level 2 Attorney Review Completed 11/17/2023 2:23 PM Procurement Services Sandra Herrera Procurement Director Review Completed 11/21/2023 2:43 PM Public Utilities Department George Yilmaz Level 2 Division Administrator Review Completed 11/27/2023 2:07 PM Office of Management and Budget Debra Windsor Level 3 OMB Gatekeeper Review Completed 11/27/2023 2:22 PM County Attorney's Office Jeffrey A. Klatzkow Level 3 County Attorney's Office Review Completed 11/27/2023 3:24 PM Corporate Compliance and Continuous Improvement Megan Gaillard Additional Reviewer Completed 11/28/2023 7:53 AM Community & Human Services Maggie Lopez Additional Reviewer Completed 11/30/2023 8:07 AM County Manager's Office Amy Patterson Level 4 County Manager Review Completed 12/01/2023 9:59 AM Board of County Commissioners Geoffrey Willig Meeting Pending 12/12/2023 9:00 AM 16.C.4 Packet Pg. 1871 PS 121.02 GIS Map and Aerial: 16.C.4.a Packet Pg. 1872 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order At pump station looking east across West Ave (2/24/2020): 4/24/2020 16.C.4.a Packet Pg. 1873 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order Looking from east side of West Ave towards pump station location (4/12/2021): Sidewalk and catch basin inlets near the pump station site (11/11/2021): 11/11/2021 4/12/2021 16.C.4.a Packet Pg. 1874 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order Looking from east side of West Ave towards pump station location (3/16/2022): Modified drainage structure west of West Ave near pump station (3/16/2022): 3/16/2022 3/16/2022 16.C.4.a Packet Pg. 1875 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order 4/6/2022 4/6/2022 note the settlement crack just to the right of the manhole 16.C.4.a Packet Pg. 1876 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order View of West Ave looking east from pump station (11/30/2022): View of road looking west towards pump station (11/30/2022): 11/30/2022 11/30/2022 16.C.4.a Packet Pg. 1877 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order View of road looking west towards pump station (11/30/2022): Dip in road near pump station viewed from the east side of West Ave (11/30/2022): 11/30/2022 11/30/2022 16.C.4.a Packet Pg. 1878 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order Closer view of road from east side (11/30/2022): 11/30/2022 16.C.4.a Packet Pg. 1879 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order View of washout under sidewalk and drainage structures near pump station (3/28/2023): A dip in the road near the pump station has been patched to prevent further damage until the improvements are completed. This was observed from the east side of West Ave on 7/14/2023: 3/28/2023 7/14/2023 16.C.4.a Packet Pg. 1880 Attachment: 1.Project location and Timeline Exhibit Photos (27285 : Recommendation to approve Change Order No. 1, under Purchase Order Purchase Order number must appear on all related correspondence, shipping papers and invoices: Printed 11/02/2021 @ 13:30:55 Page 1 of 1414-263614-634999-70240.4.2 Collier County Board of County Commissioners Procurement Services Division Phone: 239-252-8407 Fax: 239-732-0844 Tax Exempt: 85-8015966531C-1 Collier County Board of County Commissioners Attn: Accounts Payable 3299 Tamiami Trl E Ste 700 Naples FL 34112-5749 OR email to: bccapclerk@collierclerk.com Send all Invoices to: VENDOR Terms and Conditions The VENDOR agrees to comply with all Purchase Order Terms and Conditions as outlined on the Collier County Procurement Services Division site: http://www.colliercountyfl.gov/home/showdocument?id=74077, including delivery and payment terms. Further the VENDOR agrees to: 1. Provide goods and services outlined in this Purchase Order with the prices, terms, delivery method and specifications listed above. 2. Notify department Immediately if order fulfillment cannot occur as specified. 3. Send all invoices to:Collier County Board of County Commissioners Attn: Accounts Payable 3299 Tamiami Trl E Ste 700 Naples FL 34112-5749 OR email to: bccapclerk@collierclerk.com The Purchase Order is authorized under direction of Collier County Board of County Commissioners by: Sandra Herrera, Director, Procurement Services Division Vendor # 123603 US WATER SERVICES CORPORATION 4939 CROSS BAYOU BLVD NEW PORT RICHEY FL 34652 Purchase order PO Number 4500215169 Date 11/02/2021 Contact Person WW Projects Please deliver to: PLANNING & PROJECT MANAGEMENT DEPT Attn: Zamira DelToro 3339 TAMIAMI TRL E, STE 303 NAPLES FL 34112-5361 Delivery Date: 04/24/2022 Terms of Payment Net 28 days (20 business days) Item Material Description Order Qty Unit Price Per Unit Net Value 00010 CON Task 1 PS Rehabilitation NLS 496,270.71 EA 1.00 496,270.71 Rehabilitation of PS 121.02 70240.4.2 00020 CON Task 2 Allowance FPL Elec Serv. T&M 5,000 EA 1.00 5,000.00 00030 CON Task 3 Allowance Unforseen T&M 60,000 EA 1.00 60,000.00 561,270.71Total net value excl. tax USD 16.C.4.b Packet Pg. 1881 Attachment: 2. PO 4500215169 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase 16.C.4.c Packet Pg. 1882 Attachment: 3. 4500215169_CO#1_US Water Services Corporation Approved (27285 : Recommendation to approve Change Order No. 1, under 16.C.4.c Packet Pg. 1883 Attachment: 3. 4500215169_CO#1_US Water Services Corporation Approved (27285 : Recommendation to approve Change Order No. 1, under 16.C.4.c Packet Pg. 1884 Attachment: 3. 4500215169_CO#1_US Water Services Corporation Approved (27285 : Recommendation to approve Change Order No. 1, under 16.C.4.c Packet Pg. 1885 Attachment: 3. 4500215169_CO#1_US Water Services Corporation Approved (27285 : Recommendation to approve Change Order No. 1, under 16.C.4.c Packet Pg. 1886 Attachment: 3. 4500215169_CO#1_US Water Services Corporation Approved (27285 : Recommendation to approve Change Order No. 1, under 16.C.4.d Packet Pg. 1887 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. Bid Item No.Unit of Measure Bid Quantity Unit Price Total Amount1LS 1 4,867.20$ 4,867.20$ 2LS 1 4,560.00$ 4,560.00$ 3LS 1 3,048.00$ 3,048.00$ 4EA 2 2,755.20$ 5,510.40$ 5LF 42 130.48$ 5,480.16$ 6LF 32 117.75$ 3,768.00$ 7LF 8 471.00$ 3,768.00$ 8LF 42 600.74$ 25,231.08$ 9LF 64 294.79$ 18,866.56$ 10EA 1 3,753.60$ 3,753.60$ 11EA 3 12,161.14$ 36,483.42$ 115,336.42$ Furnish and install 15" RCPFurnish and install concrete collarFurnish and install Type C InletsSection 5 Total:Demolish, remove, and dispose of 18" RCPDemolish, remove, and dispose of 12"x18" ERCPDemolish, remove, and dispose of 12" CMPFURNISH AND INSTALL STORMWATER COMPONENTSFurnish and install 18" RCPAdditional mobilization and demobilizationAdditional survey and as-built drawingsAdditional maintenance of pedestrian and vehicular trafficDEMOLITION, REMOVAL, AND DISPOSAL OF EXISTING CONDITIONSDemolish, remove, and dispose of catch basinPump Station 121.02 Rehabilitation Stormwater Improvements CO #18/21/2023SECTION 5: STORMWATER IMPROVEMENTSDescriptionGENERAL16.C.4.d Packet Pg. 1888 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. SECTION 5 – MEASUREMENT AND PAYMENT MEASUREMENT AND PAYMENT PAGE 1 1. Additional Mobilization and Demobilization: Payment for the additional mobilization and demobilization will be made at the Contract lump sum price. Mobilization shall include all costs to move the Contractor’s equipment to the site, establish temporary facilities necessary to perform the Work, bonds, and insurance associated with the stormwater improvements. The cost for mobilization/demobilization shall not exceed ten percent (10%) of the total additional stormwater construction cost. Demobilization shall include all costs for disposal of materials, clean up, removing equipment form the site, restoration, and other miscellaneous items for completing installation and removing the Contractor’s equipment and temporary facilities from the site. All disturbed areas shall be sodded unless otherwise noted. 2. Additional Survey and As-Built Drawings: The cost for preparation of additional construction layout and survey as-builts shall be made at the Contract lump sum price. This item includes material, labor, and certification to prepare the “As-Builts” for the stormwater improvements, field verification of existing underground facilities, construction stakeout of the proposed stormwater improvements, and to survey the new stormwater facilities after they have been installed. Prior to acceptance of the project by County, the Contractor shall submit two prints, and one set of computer disk copies of AutoCAD formatted drawings marked as “Survey As- Builts”. The As-Builts shall include vertical and horizontal alignment of all mains, valves, tees, bends, reducers, fittings, air release valves, electrical conduits, electrical panels, wiring diagrams, thrust blocks, concrete collars, concrete pads, driveways, and other pertinent structures. As-Builts shall be certified by a Professional Land surveyor licensed in the State of Florida. Horizontal data shall be in Feet and projected on the Florida State Plane Coordinate System, East Zone, NAD83 (2011). Vertical data shall be in Feet referenced to the North American Vertical Datum of 1988 (NAVD88). 3. Additional Maintenance of Pedestrian and Vehicular Traffic: Payment to provide additional maintenance of pedestrian and vehicular traffic associated with the stormwater improvements in accordance with the County Maintenance of Traffic Policy and the Collier County Growth Management ROW standards will be made at the Contract unit lump sum price. The Contractor shall submit an MOT plan to the County ROW department and gain approval prior to construction. 4. Demolish, Remove, and Dispose of Catch Basin: Payment to demolish, remove, and dispose of catch basins will be made at the appropriate unit price for each catch basin removed. This item includes all labor and equipment necessary for abandonment and removal of the existing structure, protection of existing facilities, excavation, dewatering, surface restoration, cleanup, and disposal of the materials offsite. 5. Demolish, Remove, and Dispose of 18” RCP: Payment to demolish, remove, and dispose of 18” RCP will be made at the appropriate unit price per linear foot of pipe removed. This item includes all labor and equipment necessary for abandonment and removal of the existing pipe, protection of existing facilities, excavation, dewatering, surface restoration, cleanup, and disposal of the materials offsite. 6. Demolish, Remove, and Dispose of 12”x18” ERCP: Payment to demolish, remove, and dispose of 12”x18” ERCP will be made at the appropriate unit price per linear foot of pipe removed. 16.C.4.d Packet Pg. 1889 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. SECTION 5 – MEASUREMENT AND PAYMENT MEASUREMENT AND PAYMENT PAGE 2 This item includes all labor and equipment necessary for abandonment and removal of the existing pipe, protection of existing facilities, excavation, dewatering, surface restoration, cleanup, and disposal of the materials offsite. 7. Demolish, Remove and Dispose of 12” CMP: Payment to demolish, remove, and dispose of 12” CMP will be made at the appropriate unit price per linear foot of pipe removed. This item includes all labor and equipment necessary for abandonment and removal of the existing pipe, protection of existing facilities, excavation, dewatering, surface restoration, cleanup, and disposal of the materials offsite. 8. Furnish and Install 18” RCP: Payment to furnish and install 18” RCP will be made at the appropriate unit price per linear foot of pipe installed. This item includes all labor, equipment, and materials necessary to install the pipe including all necessary fittings, connections, excavation, pipe bedding, dewatering, compaction, removal and replacement of grass, sod, shrubs, asphalt pavement, sidewalks, handrails, and other surface materials not specifically designated in the plans, cleanup, testing, and all other work for a complete installation. 9. Furnish and Install 15” RCP: Payment to furnish and install 15” RCP will be made at the appropriate unit price per linear foot of pipe installed. This item includes all labor, equipment, and materials necessary to install the pipe including all necessary fittings, connections, excavation, pipe bedding, dewatering, compaction, removal and replacement of grass, sod, shrubs, asphalt pavement, sidewalks, handrails, and other surface materials not specifically designated in the plans, cleanup, testing, and all other work for a complete installation. 10. Furnish and Install Concrete Collar: Payment to furnish and install concrete collar will be made at the appropriate lump sum price. This item includes all labor, equipment, and materials necessary to install the collar including all necessary fittings, connections, excavation, pipe bedding, dewatering, compaction, removal and replacement of grass, sod, shrubs, asphalt pavement, sidewalks, handrails, and other surface materials not specifically designated in the plans, cleanup, testing, and all other work for a complete installation. 11. Furnish and Install Type C Inlets: Payment to furnish and install Type C Inlets will be made at the appropriate unit price for each inlet installed. This item includes all labor, equipment, and materials necessary to install the inlet including all necessary fittings, connections, excavation, pipe bedding, dewatering, compaction, removal and replacement of grass, sod, shrubs, asphalt pavement, sidewalks, handrails, and other surface materials not specifically designated in the plans, cleanup, testing, grading around installation in accordance with construction plans, and all other work for a complete installation. 16.C.4.d Packet Pg. 1890 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. Date Approved: August 3, 2023 Right-of-Way Permit Number: PRROW2021030862701 SDP/AR/PSP Number:Building Permit Number: Project Name: Collier County Public Utilities Wastewater Pump Station Repair and Renovation – Pump Station 121.02 Project Address: Approximately 75 West Avenue Bonita Springs, FL 34134 along the west side of the road, approximately 150 south of Bonita Beach Road. Subdivision: Little Hickory Shores Lot:Block:Unit:Tract: Folio No:Section: 5 Township: 48 South Range: 25 East ******************************************************************************************************************************************************************************** Type of Construction: ROW Commercial Detail: PERMIT MODIFICATION AUGUST 2023 - REV 1: Existing 18" stormwater culvert crossing beneath West Ave directly adjacent to the Pump Station 121.02 site had failed and caused the West Ave roadway to settle. Removal of the damaged existing stormwater infrastructure, installation of new stormwater system components, grading of the site to allow proper stormwater drainage, and restoration to impacted areas. These improvements will prevent further settling of the roadway & washout underneath the adjacent sidewalk. This project proposes improvements and repairs to Pump Station 121.02 meet the current Collier County Utility Standards including, but not limited to, replacement of the existing electrical equipment and panels, new submersible wastewater pumps, provisions for a portable emergency generator, installation of above ground HDPE discharge piping and valves, relining the interior surface of the wet well and master manhole, and the installation of a driveway apron to allow County Operations staff a safe parking area. This project also proposes the installation of a new 8” plug valve on the existing force main located approximately 900 feet south of the pump station near the intersection of West Avenue and 3rd Street West, within the County ROW. All proposed improvements will be owned and maintained by Collier County Public Utilities. 57 WEST AVE NEAR BONITA BEACH RD Please refer to Collier County Portal for issuance and expiration dates. ********************************************************************************************************************************** Property Owner: COLLIER COUNTY PUBLIC UTILITIES- JOHN EICK 3339 TAMIAMI TRL E, STE 303 NAPLES, FL 34112 Telephone Number: Contractor: U.S. Water Services Corporation 5660 Bayshore Road, Suite 36 N. Ft. Myers, FL 33917 Telephone Number: (727) 858-2396 Applicant: William Hurricane Saum - Johnson Engineering 2350 Stanford Court Naples, FL 34112 Telephone Number: (239) 461-2414 1. Work shall be performed in accordance with approved plan, stipulations specified as part of this permit and in accordance with Collier County Ordinance # 09-19 and the "Public Right-of-Way Construction Standards Handbook," latest edition. 2. Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground. Any changes to any utility shall be the responsibility of the Permittee for all cost. 3. If right-of-way permit is issued in conjunction with a residential building permit, the right-of-way permit expires upon completion of the residential building. 4. If the application is made by any person or firm other than the owner of the property involved, a written consent from the property owner shall be required prior to processing of the application. 5. Approval of this permit does not exempt the permittee from gaining approval from any State, Federal or Local Agencies having jurisdiction over the proposed work. 6. This permit is contingent upon Permittee obtaining necessary rights of entry for construction and maintenance where required right-of-way for public use has not been dedicated and accepted by Collier County. APPROVED BY: ARH Condition: All other applicable state or federal permits must be obtained before commencement of the 16.C.4.d Packet Pg. 1891 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. development. Condition: Stipulation - The required inspections shall be scheduled through the CityView Portal. You must be signed in as a registered user to schedule an inspection. Condition: Stipulation - All other applicable state or federal permits must be obtained before commencement of the development. Condition: Stipulation - Before commencement of any excavation, the existing underground utilities in the area affected by the work must be marked by Sunshine One Call, in accordance with State Statute Chapter 556 “Underground Facility Damage Prevention and Safety”, after proper notification to them by either calling 811 in Florida or toll free at 1-800-432-4770. Visit www.callsunshine.com for more information. Before commencing excavation for the work, potholing of all potential conflicts must be performed. Condition: Stipulation - Sunshine 811 Damage Prevention Guide Chapter 556, F.S., sets a tolerance zone that extends 24 inches from the outer edge of each side of an underground facility. Locate marks show the approximate location of an underground facility. To be sure where that facility is located, you must expose it using a method below: • Hand digging at an angle toward the facility • Pot holing • Soft digging • Vacuum excavation methods • Other similar procedures Exposing the facility lets you see the facility size and the clearance you need to maintain during excavation. Digging within the tolerance zone requires special precaution and using mechanized equipment requires a spotter. Within existing pavement, soft digging will be required after removal of pavement associated with a permitted open-cut. Condition: CO Hold - As Built Drawings are required prior to final inspection for all Commercial ROW permits. The as-built drawings may be submitted through the CityView Portal Conditions Tab - click "Browse" to upload the documents. You must be signed into the CityView Portal as a registered user to upload the document. Condition: Informational - To Extend a ROW Permit upload ROW Application and check Extension Box. Follow link to locate Right-of-Way Form; https://www.colliercountyfl.gov/home/showpublisheddocument/54469/637169203883770000 Condition: Stipulation - A Maintenance of Traffic plan shall be provided to the ROW Reviewer via email prior to the start of construction. Condition: Stipulation - The open cut restoration shall be completed with flowable fill. The pavement shall be saw cut, milled and repaved 25 feet on both sides of the trench. Please visit the CityView portal located at https://cvportal.colliercountyfl.gov/cityviewweb to schedule the inspections listed below. Please plan accordingly when scheduling inspections and schedule well in advance of when needed or permit expiration dates. 830 - 72 Hr Notice of (1st) Proceeding with Work 800 - Right-Of-Way Final Inspections Disclaimer: Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. SEE GENERAL CONDITIONS OF RIGHT-OF-WAY PERMITS 16.C.4.d Packet Pg. 1892 Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. GULF OF MEXICO LEE COUNTY COLLIER COUNTY DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN 01 TALLAHASSEE CHIPLEY PANAMA CITY KEY WEST SARASOTA FT MYERS FT. PIERCE DAYTONA BEACH ST AUGUSTINE GAINESVILLE OCALA BARTOW TAMPA ORLANDO DELAND LAKE CITY JACKSONVILLE LAKE OKEECHOBEE WEST PALM BEACH FT. LAUDERDALE PENSACOLA LOCATION MAP - NTS PRROW2021030862701 PERMIT PLANS WASTEWATER PUMP STATION REPAIR AND RENOVATION PUMP STATION 121.02 COLLIER COUNTY PUBLIC UTILITIES COLLIER COUNTY, FLORIDA CoverWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaVICINITY MAP - NTS LEE COUNTY COLLIER COUNTY Sheet List Table Sheet Number Sheet Title 01 Cover 02 Notes & Legends Site Plan 03 Existing 04 Demolition 05 Proposed 06 Paving, Grading, & Drainage 07 Offsite Valve Installation Collier County Utility Detail: Pump Station Details D-01 1 of 2 D-02 2 of 2 FDOT Details D-03 1 of 3 D-04 2 of 3 D-05 3 of 3 Electrical Plans E-00 Notes & Legends E-01 Bill of Material E-02 Single Line Diagram E-03 Single Line Diagram with Optional Diesel Pump E-04 Single Line Diagram with Optional Generator E-05 Single Line Diagram with Optional Portable Generator E-06 Equipment Layout with Single Door Enclosure E-07 Equipment Layout with Double Door Enclosure E-08 Equipment Layout with Optional Generator & Single Door Enclosure E-09 Equipment Layout with Optional Generator & Double Door Enclosure E-10 PCP Pump Control Panel Equipment Layout - Single Door E-11 PCP Pump Control Panel Equipment Layout - Double Door E-12 PCP Pump Control Panel Single Line Diagram with FVNR Starters E-13 PCP Pump Control Panel Single Line Diagram with VFD's E-14 PCP Pump Control Panel Schematic E-15 PCP Pump Control Panel Schematic - FVNR E-16 PCP Pump Control Panel Schematic - VFD E-17 PCP Pump Control Panel Schematic - VFD or Generator E-18 PCP Pump Control Panel Schematic - VFD or Generator E-19 PCP Pump Control Panel Schematic - Generator E-20 JB-1 Pump Junction Box Arrangement ED-01 Detail ED-02 Detail ED-03 Detail ED-04 Detail 1 2 3 2 3 2 3 1 3 3 3 3 3 3 1 1 1PRE-BID MEETING08/25/212REVISED PER SURVEY VERIFICATION02/24/223STORMWATER IMPROVEMENTS05/31/23WAYNE W . WR I GHTPROF ESSIONA L E N GINEERLIC ENSE FLOR I D ASTATE OF NO. 58220 DESIGN CONSULTANT ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.21 = NGVD 1929 PERMIT PLANS 3 This item has been digitally signed and sealed by Jordan L. Varble, P.E., on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1893Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN 02 ABBREVIATIONS ℄ ⅊ COLLIER COUNTY UTILITIES STANDARD DETAIL NOTES: Notes & LegendsWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida*PLAN SHEET NOTES: THE DESIGN TEAM WILL DETERMINE THE FOLLOWING FOR EACH PUMP STATION ASSIGNMENT PRIOR TO REQUEST FOR QUOTATIONS: -BACK UP PUMPING OPTIONS PORTABLE GENERATOR -ELECTRICAL EQUIPMENT LAYOUT OPTIONS SINGLE DOOR ENCLOSURE WITH PORTABLE GENERATOR -CONTROL PANEL ENCLOSURE OPTIONS SINGLE DOOR ENCLOSURE -PUMP START OPTIONS FVNR BASED ON THE INFORMATION ABOVE THAT WILL BE PROVIDED BY THE DESIGN TEAM, THE CONTRACTOR SHALL SELECT THE APPROPRIATE SHEETS TO BE USED. ONLY A PORTION OF THE ELECTRICAL SHEETS E-00 TO ED-04 WILL BE USED FOR EACH ASSIGNMENT. ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.09 = NGVD 1929 GENERAL NOTES: 1.ALL ELEVATIONS REFER TO NORTH AMERICA VERTICAL DATUM (N.A.V.D.) OF 1988. CONVERSION FROM N.A.V.D. TO N.G.V.D. FOR THIS AREA, + 1.21 FT. 2.HORIZONTAL DATA SHALL BE IN FEET AND PROJECTED ON THE FLORIDA STATE PLANE COORDINATE SYSTEM, EAST ZONE, NAD83 (2011). VERTICAL DATA SHALL BE IN FEET AND REFERENCED TO THE NORTHAMERICAN VERTICAL DATUM OF 1988 (NAVD88). 3.VEHICULAR AND PEDESTRIAN TRAFFIC SHALL BE MAINTAINED DURING CONSTRUCTION. THE CONTRACTOR SHALL SUBMIT A VEHICULAR AND PEDESTRIAN MOT PLAN TO THE COUNTY, ENGINEER, AND ROWDEPARTMENT FOR APPROVAL PRIOR TO CONSTITUTION. 4.ALL COLLIER COUNTY UTILITY DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS (UTILITY STANDARDS) ARE APPLICABLE TO PROJECT AND ARE MADE A PART OF THE CONTRACT DOCUMENTS BYREFERENCE TO CURRENT 2015 COUNTY UTILITIES STANDARDS. IN THE EVENT OF CONFLICT BETWEEN THE COUNTY UTILITIES STANDARD MANUAL AND THESE SPECIFICATIONS AND DRAWINGS, THE MORESTRINGENT REQUIREMENT SHALL APPLY. 5.THE LOCATIONS OF EXISTING UTILITIES AND STORM SEWERS SHOWN ON THIS PLAN HAVE BEEN TAKEN FROM RECORD DRAWINGS AND FIELD INFORMATION AND ARE APPROXIMATE ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR EXACT LOCATION PRIOR TO CONSTRUCTION AND PROVIDE IN WRITING ANY DISCREPANCIES TO THE ENGINEER. 6.IT IS THE CONTRACTOR'S RESPONSIBILITY DURING CONSTRUCTION TO PROTECT ANY EXISTING UTILITIES. 7.THE CONTRACTOR IS REQUIRED TO CONTACT ALL UTILITY OWNERS PRIOR TO THE BEGINNING OF CONSTRUCTION AND COORDINATE WITH UTILITY OWNERS DURING CONSTRUCTION. 8.EXISTING FACILITIES SHALL BE RESTORED TO A CONDITION EQUAL TO OR BETTER THAN WHAT EXISTED PRIOR TO COMMENCING CONSTRUCTION, AT NO ADDITIONAL COST TO OWNER. 9.IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPLACE ANY EXISTING LANDSCAPING (I.E. SOD, BUSHES, TREES, ETC.), SPRINKLER PIPING, SPRINKLER HEADS AND FENCING THAT MAY HAVE BEEN REMOVED OR HAS BEEN DAMAGED DURING CONSTRUCTION. CONTRACTOR TO REPLACE OR REPAIR ANY DAMAGED PROPERTY OR IMPROVEMENTS TO A CONDITION EQUAL TO OR BETTER THAN EXISTED PRIOR TO CONSTRUCTION. 10.ALL DRIVEWAYS, SIDEWALK, AND OTHER EXISTING FACILITIES, UTILITIES, AND IMPROVEMENTS SHALL BE RESTORED EQUAL TO PRE-CONSTRUCTION CONDITIONS OR BETTER AND TO THE SATISFACTION OF THE OWNER. 11.ANY PROPERTY CORNER WITHIN THE LIMITS OF CONSTRUCTION IS TO BE PROTECTED. IF A CORNER MONUMENT IS IN DANGER OF BEING DISTURBED THE CONTRACTOR SHALL PROPERLY REFERENCE ITSLOCATION TO BE RESET BY THE CONTRACTOR'S FLORIDA LICENSED SURVEYOR, ANY SURVEY MONUMENTS AND PRIVATE PROPERTY CORNER DISTURBED BY CONSTRUCTION ACTIVITIES SHALL BE REPLACED BYTHE CONTRACTOR AT HIS OWN COST. 12.THE CONTRACTOR IS REQUIRED TO ADJUST ALL VALVE BOXES, MANHOLE RIMS, GRATES, ETC. AS NECESSARY TO MATCH PROPOSED GRADES. 13.DAMAGE TO EXISTING UTILITIES AND PROPERTY DURING CONSTRUCTION SHALL BE REPAIRED AND/OR REPLACED AT CONTRACTOR EXPENSE. 14.THE CONTRACTOR SHALL PROVIDE 72 HOURS WRITTEN NOTICE TO THE ENGINEER OF RECORD, OWNER'S CEI REPRESENTATIVE, AND COLLIER COUNTY PROJECT MANAGER PRIOR TO THE FOLLOWING ACTIVITIES: a.COMMENCEMENT b.CHANGES TO APPROVED SCHEDULES, SUBCONTRACTORS, AND RESIDENT SUPERINTENDENT c.WASTEWATER SYSTEM: d.TESTING OF BYPASS PUMP SYSTEM e.TEMPORARY AND PERMANENT FORCEMAIN PRESSURE TESTS f.PUMP STATION START-UP 14.THE CONTRACTOR SHALL NOTIFY COLLIER COUNTY UTILITIES DEPARTMENT AT LEAST THREE FULL WORK DAYS IN ADVANCE OF ALL PLANNED SERVICE INTERRUPTIONS, AND RECEIVE COUNTY PROJECTMANAGER'S APPROVAL BEFORE PROCEEDING WITH PLANNED INTERRUPTIONS. 15.SHOP DRAWINGS FOR ANY EQUIPMENT AND MATERIAL MUST BE APPROVED PRIOR TO FABRICATION AND INSTALLATION. 16.CONTRACTOR SHALL RETAIN, ON THE WORK SITE, COPIES OF ALL PERMITS NECESSARY FOR CONSTRUCTION. 17.CONTRACTOR IS REQUIRED TO OBTAIN FROM THE ENGINEER OF RECORD AND COUNTY PROJECT MANAGER WRITTEN APPROVAL FOR ANY DEVIATIONS FROM THE PLANS AND/OR SPECIFICATIONS. 18.CONTRACTOR SHALL PROMPTLY REPORT ALL FIELD CHANGES TO THE ENGINEER OF RECORD AND CEI REPRESENTATIVE. 19.CONTRACTOR WILL BE RESPONSIBLE FOR STORING ALL MATERIALS FOR THE PROJECT INCLUDING ALL MATERIALS PURCHASED BY COLLIER COUNTY IN SECURE STORAGE AREA. 20.CONTRACTOR IS RESPONSIBLE FOR MAINTAINING UTILITY SERVICE AT ALL TIMES DURING CONSTRUCTION WITHIN THE PROJECT LIMITS. THIS INCLUDES HAVING A SUPPLY OF REPAIR MATERIALS ONSITE THAT MATCHES EXISTING IN THE EVENT OF A BREAK. 21.CONTRACTOR WILL BE EXPECTED TO PROVIDE A TWO (2) WEEK LOOK AHEAD FOR ALL CONSTRUCTION ACTIVITIES AND ATTEND WEEKLY OR BI-WEEKLY MEETINGS AT THE COUNTY'S DISCRETION. 22.CONTRACTOR SHALL NOT LEAVE TRENCHES OR HOLES OPEN OVERNIGHT OR OVER WEEKENDS. 23.ALL CONSTRUCTION DEBRIS AND OTHER WASTE MATERIAL SHALL BE DISPOSED OF OFFSITE IN ACCORDANCE WITH APPLICABLE REGULATIONS. 24.WORK AREAS ARE TO BE CLEANED ON A DAILY BASIS. 25.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING RIGHT-OF-WAY, TREE REMOVAL, AND DEWATERING PERMITS IF REQUIRED. 26.ACCESS ONTO EXISTING STREETS AND DRIVES SHALL BE MAINTAINED TO LOCAL TRAFFIC AND PROPERTY OWNERS, RESPECTIVELY. CONTRACTOR SHALL LIMIT CONSTRUCTION ACTIVITIES ON PUBLIC ORPRIVATE ROADWAYS. 27.THE CONTRACTOR SHALL FURNISH TO THE ENGINEER RECORD DRAWINGS CERTIFIED BY A FLORIDA LICENSED LAND SURVEYOR AND MAPPER. THE INFORMATION SHALL DEPICT THE AS-BUILT LOCATION OF ALLIMPROVEMENTS, INCLUDING, BUT NOT LIMITED TO, CONDUITS, PIPING, CONCRETE PAD LIMITS AND DIMENSIONS, BOLLARD POSTS, PANEL LIMITS AND DIMENSIONS, GRAVEL AND SOD LIMITS, EQUIPMENT LIMITSAND DIMENSIONS, WIRING DIAGRAMS, ETC.VALLEY DRIVEWEST AVENUEGARY ROAD IMPERIAL SHORES BLVD.BONITA BEACH ROAD PUMP STATION 121.02 *ELECTRICAL PLAN SHEET MATRIX: THE ELECTRICAL PLAN SHEET MATRIX INDICATES THE APPROPRIATE ELECTRICAL PLAN SHEETS TO USED BASED ON THE SCOPE OF THE PUMP STATION ASSIGNMENT.3STORMWATER IMPROVEMENTS05/31/233 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1894Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Site Plan ExistingWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida03 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN PICTURE #1PICTURE #2 PICTURE #3 PICTURE #4 PICTURE #5 PICTURE #5 PICTURE #4 PICTURE #3 PICTURE #2 PICTURE #1 ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.21 = NGVD 1929 EXISTING CONDITIONS NOTES: 1.THE PORTION OF 12" GRAVITY SEWER BETWEEN THE MASTER MANHOLE AND WET WELL WAS REPLACED WITH PVC DURING APRIL 2021 AS PART OF AN EMERGENCY REPAIR. 2.THERE IS APPROXIMATELY 5 LF OF PVC SANITARY SEWER MAIN EXTENDING TO THE NORTH AND TO THE SOUTH FROM THE MASTER MANHOLE BEFORE TRANSITIONING TO VITRIFIED CLAY PIPE MATERIAL.WEST AVENUE2REVISED PER SURVEY VERIFICATION02/24/222 3 3 3 3 3 3STORMWATER IMPROVEMENTS05/31/233 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1895Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida04 Site Plan Demolition DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN DEMOLITION NOTES: 1.CONTRACTOR TO DEMOLISH, REMOVE, AND DISPOSE OF WET WELL TOP CONCRETE LID, HOOKS, RAILS, DISCHARGE RISER PIPES, VALVE VAULT, VAULT PIPING AND VALVES, CHAINS AND OTHER MISC. WET WELL COMPONENTS. 3.VERTICAL WET WELL CYLINDRICAL SECTIONS TO REMAIN. 4.CONTRACTOR TO ABANDON, REMOVE, AND DISPOSE MASTER MANHOLE. 5.CONTRACTOR TO ABANDON, REMOVE, AND DISPOSE OF PUMP CONTROL PANEL, SERVICE METER, ANTENNA, EQUIPMENT RACK, AND OTHER MISC PANELS / BOXES / COMPONENTS. 6.CONTRACTOR SHALL COORDINATE WITH THE POWER UTILITY PROVIDER. 7.CONTRACTOR TO MAINTAIN WASTEWATER SERVICE VIA BYPASS PUMPING DURING ALL DEMOLITION AND CONSTRUCTION. 8.CONTRACTOR TO CLEAR, GRUB, REMOVE, AND DISPOSE OF EXISTING VEGETATION. 9.ODOR CONTROL UNIT AND ASSOCIATE PIPING TO REMAIN. 10.REPLACE ANY DISTURBED LANDSCAPING OR HARDSCAPING, UNLESS OTHERWISE NOTED. 11.EXISTING 12" PVC SANITARY SEWER TO REMAIN. ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.09 = NGVD 1929 CLEAR, GRUB, REMOVE, AND DISPOSE OF VEGETATION CLEAR, GRUB, REMOVE, AND DISPOSE OF VEGETATION CLEAR, GRUB, REMOVE AND DISPOSE 12" TREE DEMO, REMOVE AND DISPOSE 75 LF 5' HIGH CHAIN LINK FENCE ABANDON, REMOVE, AND DISPOSE MASTER MANHOLEWEST AVENUEABANDON, REMOVE AND DISPOSE PUMP CONTROL PANEL, ELECTRICAL PANELS AND COMPONENTS, POWER METER, EQUIPMENT RACK, AND TELEMETRY ANTENNA. DEMO, REMOVE AND DISPOSE OF CONC. SIDEWALK AND HAND RAIL. DEMO, REMOVE AND DISPOSE WET WELL LID AND ACCESS HATCHES, AND WET WELL COMPONENTS. WET WELL STRUCTURE TO REMAIN. DEMO, REMOVE AND DISPOSE DISCHARGE PIPING AND VALVES, VALVE VAULT AND ACCESS HATCHES ABANDON, REMOVE, AND DISPOSE 32 LF OF 8" CAST IRON FORCE MAIN 2REVISED PER SURVEY VERIFICATION02/24/222 DEMO, REMOVE AND DISPOSE CATCH BASIN DEMO, REMOVE AND DISPOSE CATCH BASIN DEMO, REMOVE AND DISPOSE 42 LF OF 18" RCP DEMO, REMOVE AND DISPOSE 39 LF OF 12"X18" ERCP 3STORMWATER IMPROVEMENTS05/31/23DEMO, REMOVE, AND DISPOSE PORTION OF 12" CMP 3 3 3 3 3 3 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1896Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) XXXXXXXXXXXX X X X X X FMWM Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida05 Site Plan Proposed DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN SEE SHEETS D-01-D-02 FOR PUMP STATION 121.02 DETAILS PUMP NO.PUMP #1 EXISTING OR PROPOSED PUMP MANUFACTURER PUMP MODEL NO. IMPELLER NO. DESIGN PUMP HEAD DESIGN PUMP RATE DESIGN PUMP SPEED PUMP POWER PUMP VOLTAGE PUMP PHASE DISCHARGE SIZE PUMP #2 (FT) (GPM) (RPM) (HP) (VOLTS) (PH) (IN) PUMP INFORMATION PROPOSED FLYGT NP 3127 489 36 475 1750 7.5 230 3 3 STATION INFORMATION 6 6 12 6 6.73 - 8.67 - 8.17 - 8.67 - 9.17 - 12.27 RISER PIPE DIAMETER (IN) PIPE DIAMETER AFTER RISER WET WELL WALL THICKNESS DIAMETER OF WET WELL (ID)(FT) LEAD PUMP ON EL HIGH WATER EL PUMP OFF EL LAG PUMP EL TOP OF WET WELL EL BOTTOM OF WET WELL EL GRAVITY SEWER INVERT EL BOTTOM OF CONTROL PANEL EL (FT, NAVD) (FT, NAVD) (FT, NAVD) (FT, NAVD) (FT, NAVD) (FT, NAVD) (FT, NAVD) (IN) (IN) - 13.77 (FT, NAVD) PROPOSED SAN MH#1 48" DIAM. POLYMER CONC. ELEVATIONS TO MATCH PAVEMENT AND EXISTING INVERT ELEVATIONS 10WET WELL TOP THICKNESS (IN) ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.09 = NGVD 1929 PROPOSED FLYGT NP 3127 489 36 475 1750 7.5 230 3 3 (EXISTING, ESTIMATE) (EXISTING) (EXISTING) (EXISTING) (EXISTING) PROPOSED 20'x22' - 4" THICK <1" DIAMETER STONE PROPOSED 16'x8' - 6" THICK COMPACTED LIMESTONE (AREA FOR TRAILER MOUNTED GENERATOR) 20' 16' 36x54ACCESS HATCH CLEAR OPENING (IN) PROPOSED PROTECTIVE LINER ON WET WELL INTERIOR SURFACE. WET WELL FLOOR TO BE MADE LEVEL AND FLAT. RESTORE CONCRETE SIDEWALK SQUARES WITHIN TRENCH AREA AND ONE SQUARE ON EACH SIDE OF TRENCH IN ACCORDANCE WITH THE COLLIER COUNTY ROW HANDBOOK. RESTORE ASPHALT ROADWAY IN ACCORDANCE WITH COLLIER COUNTY ROW HANDBOOK. PROPOSED GENERATOR RECEPTACLE, AUTOMATIC TRANSFER SWITCH,MAIN DISCONNECT, PANEL BOARD, POWER METER, JUNCTION BOX, AND PUMP CONTROL PANEL ON EQUIPMENT RACK AND 13'x4' CONC. PAD 24' 3' 9' 3' 30' PROPOSED CONCRETE DRIVEWAY (MINIMUM)10.00 PROPOSED TELEMETRY ANTENNA PROPOSED 6' TALL VINYL COATED CHAIN LINK FENCE WITH BLACK SLATS WEST AVENUEPROPOSED 8" FM - PVC DR14 BYPASS PUMPING NOTES: 1.CONTRACTOR TO PROVIDE BYPASS PUMPING WHILE PUMP STATION IS OFF LINE. WASTEWATER SERVICE SHALL BE MAINTAINED DURING ALL PORTIONS OF CONSTRUCTION. 2.BEFORE PLACING THE PUMP STATION OUT OF SERVICE, THE BYPASS SYSTEM SHALL OPERATE WITHOUT ISSUE FOR A MINIMUM OF 48 HOURS PRIOR TO THE PUMP STATION SHUT DOWN. 3.BEFORE PLACING THE PUMP STATION INTO SERVICE, THE PUMP STATION SHALL OPERATE WITHOUT ISSUE FOR A MINIMUM OF 48 HOURS PRIOR TO DEMOBILIZING THE BYPASS SYSTEM. 4.CONTRACTOR MAY UTILIZE EXISTING MANHOLE FOR BYPASS PUMPING 5.REQUIRED CAPACITY FOR BYPASS PUMPING IS APPROXIMATELY 475 GPM @ 24 FT, NAVD HGL. 6.CONTRACTOR TO INSTALL PUMP OUT CONNECTION DOWNSTREAM OF VALVE VAULT FOR BYPASS PUMPING. PUMP STATION IMPROVEMENTS NOTES: 1.PUMP STATION TO BE CONSTRUCTED PER THE CURRENT COLLIER COUNTY UTILITIES DESIGN STANDARDS AND DETAILS UNLESS OTHERWISE NOTED. 2.ALL ABOVE GROUND PIPING TO BE HDPE DR 11 DIPS. 3.ABOVE GROUND CHECK VALVES AND PLUG VALVES TO BE PAINTED HUNTER GREEN. COLOR CODE PROVIDED ON DETAIL SHEET D-01. 4.BELOW GROUND VALVE CAPS TO BE PAINTED GREEN. 5.CONCRETE VALVE PADS FOR BELOW GROUND VALVES SHALL HAVE BRASS TAGS PER CURRENT COUNTY STANDARDS. 6.SEE ELECTRICAL SHEETS FOR ELECTRICAL IMPROVEMENTS. 7.WET WELL FLOOR SHALL BE LEVEL AND FLAT USING WET WELL PROTECTIVE LINER. 8.H-TECH ARV REQUIRED. 9.SEE DETAIL SHEET D-01 FOR ACCESS HATCH ORIENTATION. PROPOSED VEHICLE GUARD POST TYPICAL PROPOSED 8" FM - 45° BEND CONNECT TO EXISTING 8" FM PROPOSED TEMPORARY FDOT INDEX 102 TYPE III SILT FENCE DURING CONSTRUCTIONPROPOSED (7) CLUSIA GUTTIFERA 36" HT., 3/ O.C. WITH 3" THICK SHREDDED HARDWOOD MULCH 6" AWAY FROM TRUNK PROPOSED 8" PLUG VALVE RELOCATE EX. WATER METER & BACKFLOW COORDINATE WITH COLLIER COUNTY WATER DEPARTMENT 1PRE-BID MEETING08/25/211 1 1 1 RELOCATE WATER METER & BACKFLOW SEE SHEETS 06 FOR PAVING, GRADING, AND DRAINAGE 4' 13'3STORMWATER IMPROVEMENTS05/31/233 3 3 3 PROPOSED 6" THICK CONCRETE SIDEWALK PROPOSED HAND RAIL 8' 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1897Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) XXXXXXXXXXXX X X X X X FMWM B B AA6.176.17MATCH EXISTINGMATCH EXISTING MATCH EXISTING MATCH EXISTING 6.736.736.736.306.306.306.305.006.306.30Profile View of A Sta: 0+00 to Sta: 0+60 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3:1 MA X .3:1 MAX. 3:1 MA X . Profile View of B Sta: 0+00 to Sta: 0+30 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3:1 MAX.3:1 MAX.Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida06 Site Plan Paving, Grading, & Drainage DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN SEE SHEETS D-01-D-02 FOR PUMP STATION 121.02 DETAILS ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.09 = NGVD 1929 PROPOSED 20'x22' - 4" THICK <1" DIAMETER STONE PROPOSED 16'x8' - 6" THICK COMPACTED LIMESTONE (AREA FOR TRAILER MOUNTED GENERATOR) PROPOSED CONCRETE DRIVEWAYWEST AVENUE1PRE-BID MEETING08/25/21PROPOSED TOE OF DITCH PROPOSED TOP OF DITCH PROPOSED TYPE C INLET GRATE EL: 5.0 PR. 15" RCP INV: 2.7 (N) PROPOSED TYPE C INLET GRATE EL: 6.0 PR. 15" RCP INV: 1.9 (N) PR. 18" RCP INV: 1.9 (E) PR. 15" RCP INV: 1.9 (S) EX. 18" RCP INV: 1.9 (W) PROPOSED TYPE C INLET GRATE EL: 5.0 PR. 18" RCP INV: 2.7 (W) PROPOSED 22 LF - 15" RCP PROPOSED CONCRETE COLLAR PROPOSED 42 LF - 15" RCP PROPOSED 42 LF - 18" RCP PROPOSED 20'x22' - 4" THICK <1" DIAMETER STONEPROPOSED 16'x8' - 6" THICK COMPACTED LIMESTONE (AREA FOR TRAILER MOUNTED GENERATOR) PROPOSED 13'X4' CONC. PAD FOR ELECTRICAL EQUIPMENT SEE SHEET 05 FOR PUMP STATION SITE PLAN PROPOSED GRADE PROPOSED GRADE Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1898Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) WM Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, Florida07 Site Plan Offsite Valve Installation DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN ELEVATIONS REFERENCE NAVD 1988. CONVERSION TO NGVD 1929 IS: NAVD1988 + 1.09 = NGVD 1929 SEE SHEET 05 FOR PROPOSED IMPROVEMENTS FOR PUMP STATION 121.01 CONTRACTOR TO INSTALL NEW 8" PLUG VALVE ON EXISTING 8" FM - (CAST IRON MAIN) 3RD STREET WEST 3RD STREET 2ND STREET WEST 2ND STREET 1ST STREET WEST 1ST STREET BONITA BEACH ROAD WEST AVENUEWEST AVENUEAPPROXIMATELY 910 L.F.SOUTH OF PUMP STATION 121.01EX. AIR RELEASE VALVE EX. 4" VALVE 3" MULCH, 6" AWAY FROM TRUNK FINISHED GRADE ROOTBALLS SHALL SIT ON UNDISTURBED SOIL. FILL AROUND ROOTBALL WITH BACKFILL, FLOOD, & COMPACT FILL TO INSURE THE ELIMINATION OF AIR POCKETS. FERTILIZE AS PER PLANTING NOTES. BACKFILL MATERIAL TO CONSIST OF NATIVE SOIL FROM PIT DUG FOR FIELD DUG MATERIAL ONLY. FOR CONTAINER PLANTS, AMEND BACKFILL (1/2 NATIVE SOIL & 1/2 SOIL AMENDMENTS). CONSTRUCT AND COMPACT A 6" CONTINUOUS SAUCER AROUND THE TREE PLANTING PIT FOR WATER RETENTION. TOP OF ROOT BALL SHALL BE AT LEAST 1" ABOVE THE FINISHED GRADE. REMOVE TOP 1/3 OF DEGRADABLE BURLAP AND TUCK BELOW SOIL TO AVOID WICKING. DO NOT DISTURB BURLAP AROUND FIBROUS ROOTS. REMOVE ALL NON-BIODEGRADEABLE MATERIALS FROM PLANT/PIT. SCORE ROOTS ON CONTAINER TO INSURE SPREADING INTO BACKFILLED SOIL. PRUNE SHRUBS IN ACCORDANCE WITH NATIONAL ARBORIST ASSOCIATION STANDARDS TO ACHIEVE PROPER HEALTH AND A UNIFORM MASS. TYPICAL SHRUB PIT PLANTING N.T.S. ESTABLISHMENT WATERING SCHEDULE *CONTRACTOR IS ONLY RESPONSIBLE FOR WATERING UP TO FINAL COMPLETION.1PRE-BID MEETING08/25/211 1 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1899Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) 12'-0" #4 DOWELS @ 12" C/C X:1'-0"GENERATOR (SLAB/REINF.) 8" (3)#4 CONT.1 1 #4 @ 12" O/C, EW, TOP & BOTTOM 1'-6"T.O. CONC 100 YEAR FLOOD EL. NOTE: CONTRACTOR SHALL PROVIDE A 3/8" CLOSED CELL NEOPRENE PAD ON THE SLAB TO MATCH THE BASE FOOTPRINT OF THE GENERATOR OR THE DIESEL PUMP.6'-0"8" GRANULAR, FREE DRAINING SAND UNDER SLAB, COMPACTED TO (98% MODIFIED PROCTOR) ASTM D1557 1 1 1'-6"8"8"#5@12" O/C, EW,MID-DEPTH #5@12" O/C, EW BROOM FINISH 6" FREE-DRAINING,CLEAN GRANULARMATERIAL COMPACT SUBGRADE TO A DENSITY OF 95% PER ASTMD-1557 (MODIFIED PROCTOR) 1"132" SLOPED CONCRETE PAD SLOPED CONCRETE EQUIPMENT PAD 11'-0" STRUCTURAL NOTES: 1.ALL CONCRETE SHALL BE 4000 PSI MINIMUM COMPRESSIVE STRENGTH; W/C = 0.45, AIR CONTENT 6% (±) 1%; SLUMP = 4" BEFORE ADDING WATER REDUCING AGENT. 2.ALL STEEL SHALL BE ASTM A615, GR 60. 3.ALL DIMENSIONS SHOWN ARE TYPICAL ONLY. CONTRACTOR TO VERIFY OVERALL SLAB SIZE WITH EQUIPMENT MANUFACTURER AND ENGINEER PRIOR TOCONSTRUCTION. 4.ALL SLABS SHALL HAVE TOOLED EDGES ON ALL SIDES8'-0"FIN GR. #5 AT 12" EW, CENTER PLAN 6'-0"4'-0"6"PROFILE T.O. CONC 100 YEAR FLOOD EL. T.O. CONC 100 YEAR FLOOD EL 2" TO 6"3/8" NEOPRENE PAD EDCBAPIPE 301817 1 1 1 1 7 7 7 7 7 1 4 3/163 4 13/16 5 7/16 8 7/16 6 15/16 3 3 3 3 4 5 6 10 8 * ALL DIMENSIONS IN INCHES. 312 9 15/16 MINSIZE MAX STEEL PLATE 1/2" 316 SS THICK SQUARE 1/4"BA C PROCESS PIPE 1" NON-SHRINK GROUT (TYP OF 4) LEVELING NUTS ANCHORS WITH 5/8" 316 SST WEDGE GRADE (DIMENSION "E") REQUIRED PIPE PIPE CUT TO MEET SCHEDULE 40 316 SS 1/4" NEOPRENE PAD 316 SST U-BOLT NOTES: 1.PIPE SUPPORT HEIGHT TO BE ADJUSTABLE. 2.SEE PLANS AND SECTIONS FOR PIPE GRADE REQUIREMENT (DIMENSION "E"). 3.PIPE SUPPORT TO BE COMPATIBLE WITH HDPE PIPE. 4.ALL MATERIALS AND HARDWARE TO BE 316 SS. CONSTRUCT 18" x 18" x 6" CONC BASE WITH # 4 REINFORCING STEEL @ 5" OCEW IF SUPPORT IS NOT LOCATED ON AN EXISTING SLAB. STANCHION 316 SS SADDLE 3018 3018 3018 3018 3018 ED SLATS DETAIL NOTE: COLOR OF THE SLATS SHALL BE GREEN OR BLACK TO MATCH VINYL COATED PARTS 2" GRADE 3000 PSI CONCRETE TURNBUCKLE TRUSS BARS 3/8" ROUND BARSSTRETCHER TOP RAIL MIN. 6'-0"3'-0"6"6" 10'-0" TO CENTER (MAX) CORNER POST GALV. POST CAP SPACING14" MAX.#9 GALV. CLIPS 1'-0" 316 SS TENSION WIRE LINE POST 12" O.C. 316 SS #9 TIE WIRES STRETCHERBARS TRUSS BARSAS REQUIRED GALV. POST CAP 3" ±1" ONE PIECE TRACK AND TOP RAIL ROLLER GUIDE 8.625" OD (SCHDEULE 40 PIPE) POST CAP 4'-0"2" 2.0"2.0" 2"4'-0"8.625" OD GALV.STEEL POST(SCHEDEULE 40 PIPE)3'-0"1'-0" 316 SS #9 TIE WIRES12" O.C. ASSEMBLY GALV. STEEL POSTS GRADE ROLLER GUIDE ASSEMBLY FABRIC NOTES: 1.ALL FENCING COMPONENTS SHALL BE VINYL COATED GREEN OR BLACK AS APPLICABLE. NOTES: 1.ALL FENCING COMPONENTS SHALL BE VINYL COATED GREEN OR BLACK AS APPLICABLE. WET WELL LID AND HATCH ORIENTATION DETAIL HATCH HINGES HATCH HANDLE AND LOCKING HASP HOLES FOR DISCHARGE PIPING WET WELL LID EX. WET WELL HATCH HINGES #1 #2 DOUBLE DOOR ACCESS HATCH (#1 & #2) DISCHARGE VALVE PAINT MIX * **SEE SHEET 03 FOR DIMENSIONS D-01 Collier County Utility Pump Station Details 1 of 2Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaD-01 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN NO GATE PROPOSED NOT PROPOSED NOT PROPOSED 1PRE-BID MEETING08/25/211 1 1 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1900Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaD-02 Collier County Utility Pump Station Details 2 of 2 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN NOT PROPOSED NOT PROPOSED Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1901Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWNWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaD-03 FDOT Details 1 of 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1902Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWNWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaD-04 FDOT Details 2 of 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1903Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWNWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaD-05 FDOT Details 3 of 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1904Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Notes & LegendsWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-00 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN 1.ALL NEW CONSTRUCTION SHALL COMPLY WITH APPLICABLE N.E.C. AND LOCAL CODES. 2.CONDUCTORS SHALL NOT BE SPLICED. 3.ALL CONDUCTORS SHALL BE 600-VOLT RATED, STRANDED COPPER. #8AWG AND LARGER SHALL BE RATED 90 DEGREE CELSIUS INSULATED STRANDED COPPER CONDUCTORS, THHN-2 OR XHHW-2. ALL MULTICONDUCTOR CONTROL CABLE SHALL BE #14 AWG XHHW-2, OMNICABLE P/N AF114XX, OR EQ. 4.ALL CONDUITS SHALL BE SCHEDULE 80 PVC UNLESS OTHERWISE NOTED. 5.USE PVC LONG SWEEP BENDS UNDERGROUND. 6.ALL BONDING CONDUCTORS SHALL BE ROUTED IN SCHEDULE 80 PVC CONDUIT. GROUND WIRE FROM SERVICE SHALL BE INSTALLED IN SCH. 40 CONDUIT. 7.TOP PENETRATIONS OF ELECTRICAL ENCLOSURES ARE NOT PERMITTED, UNLESS NOTED. ALL PENETRATIONS IN ELECTRICAL EQUIPMENT SHALL BE BOTTOM-ENTRY, UNLESS NOTED OTHERWISE. 8.ALL RACEWAYS SHALL HAVE AN INSULATED COPPER SYSTEM GROUND CONDUCTOR THROUGHOUT THE ENTIRE LENGTH OF THE CIRCUIT INSTALLED PER N.E.C. 9.ALL RACEWAYS WHICH ARE INSTALLED FOR FUTURE USE SHALL HAVE A NYLON PULLCORD. 10.PVC CONDUIT JOINTS SHALL BE SOLVENT-WELDED, EXCEPT FOR RIGID METALLIC TO PVC COUPLINGS. 11.MINIMUM CONDUIT SIZE SHALL BE 3/4". MINIMUM LIQUIDTIGHT FLEXIBLE STEEL CONDUIT SIZE SHALL BE 1/2". 12.ALL RACEWAYS SHALL BE RUN IN NEAT AND WORKMANLIKE MANNER AND SHALL BE PROPERLY SUPPORTED PER N.E.C. 13.ALL CONNECTIONS TO MOTORS AND OTHER VIBRATING EQUIPMENT OR AT OTHER LOCATIONS WHERE REQUIRED SHALL BE MADE WITH FLEXIBLE LIQUID-TIGHT STEEL CONDUIT 12" TO 36" IN LENGTH. 14.ALL FEEDER AND BRANCH CIRCUIT WIRING SHALL BE COLOR CODED AS FOLLOWS: 3-PHASE 480Y/277VAC (A/B/C/N/G) :PUR/BRN/YEL/WHT/GRN 3-PHASE 240/120VAC (A/B(HI)/C/N/G) :BLK/RED(ORG)/BLU/WHT/GRN 1-PHASE AC POWER :BLK, 12 AWG MIN. AC POWER HOT :BLK, 12 AWG MIN. AC POWER NEUTRAL :WHT, 12 AWG MIN. AC SWITCHED : RED, 16 AWG MIN. EXTERNALLY POWERED :YEL, 16 AWG MIN. GROUND :GRN, 12 AWG MIN. DC + :BLU, 16 AWG MIN. DC - :BLU WITH WHT STRIPE, 16 AWG MIN. TSP (+/-) :RED/BLK, 16 AWG. MIN., BELDEN 1118A, OR EQ. 15.CONTROL PANEL WIRING TO UTILIZE SCREW TYPE TERMINALS WITH LOCKING FORK TONGUE OR RING TONGUE LUGS. MAX. OF ONE WIRE TO BE TERMINATED IN A CRIMP LUG. MAX. OF TWO LUGS TO BE INSTALLED IN A SCREW TERMINAL. 16.DC AND AC CIRCUITS SHALL BE ON SEPARATE TERMINAL BLOCK STRIPS. 17.ETHERNET CABLE SHALL BE CAT-5e 600V UL AWM RATED 18.ALL WIRES AND CABLES SHALL BE MARKED USING WHITE HEAT SHRINK MARKERS. 19.BRANCH CIRCUITS EXCEEDING 75' SHALL BE WIRED WITH MINIMUM #10AWG WIRE. 20.ALL OUTDOOR ENCLOSURES TO MEET FBC WIND LOAD REQUIREMENTS FOR 150MPH. 21.PROVIDE DESSICANT PACKETS IN DISCONNECT SWITCHES AND CONTROL PANEL ENCLOSURES, SIZED ACCORDINGLY. 22.ALL RACEWAYS SHALL BE RUN IN NEAT AND WORKMANLIKE MANNER, PROPERLY SUPPORTED. 23.ALL EXISTING EQUIPMENT, CABLING, AND CONDUIT DESIGNATED TO BE REPLACED SHALL BE DEMOED AND REMOVED BY THE CONTRACTOR. 24.COORDINATE ALL SERVICE ENTRANCE WORK WITH FP&L, AND ADHERE TO ALL UTILITY STANDARDS. 25.PROVIDE TYPED CIRCUIT DIRECTORIES FOR ALL PANELBOARDS. 26.CONTRACTOR SHALL APPLY FOR AND SCHEDULE INSTALLATION OF NEW SERVICES AND REQUEST CONFIRMATION PER PLANS OF MAX AVAILABLE FAULT CURRENT FROM THE UTILITY. 27.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING THE WORK AND FURNISHING ALL MATERIALS OUTLINED IN THESE PLANS AND ANY OTHER MATERIALS AND WORK NECESSARY FOR A FULLY OPERATIONAL SYSTEM. 28.ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL EXTERNALLY-MOUNTED SURGE PROTECTOR AS SHOWN. INSTALL SPD AND CUT SPD LEADS SO THAT LEADS ARE AS SHORT AND STRAIGHT AS POSSIBLE. MOUNT TO ENCLOSURE BOTTOM WITH STATUS LIGHTS FACING FRONT. INSTALL AND BIND THE LEAD WIRES TOGETHER WITH ONE TWIST/INCH TO REDUCE THE LEAD WIRE IMPEDANCE. 29.CUSTOM ELECTRICAL ENCLOSURES TO BE UL508A LISTED. 30.ALL ELECTRICAL ENCLOSURES TO HAVE PADLOCKING PROVISIONS. 31.NAMEPLATES TO BE ADHESIVE BACKED, PHENOLIC, UV RATED. 32.PROVIDE 2" MIN. SPACE FROM TERMINAL BLOCKS TO WIRE DUCT. 33.DC AND AC CIRCUIT WIRING TO BE TERMINATED ON SEPARATE TERMINAL STRIPS. 34.ALL WIRES 10 AWG AND SMALLER TO UTILIZE FORK TONGUE, RING TONGUE, OR FERRULES. WIRE CRIMP LUGS TO HAVE ONLY ONE WIRE, TERMINAL BLOCKS TO HAVE NO MORE THAN TWO WIRES PER LUG. 35.ONLY A PORTION OF THE REQURIED CONDUIT RUNS ARE SHOWN. 36.LABEL ALL ELECTRICAL EQUIPMENT USING MIN. 1/2" BLACK LETTERING ON WHITE PLASTIC LABELS SS SCREW MOUNTED ON TO FRONT OF ALL PANELS AND CABINETS. 37.MAJOR COMPONENTS AND GENERAL ARRANGEMENT ARE PROVIDED AS A BASIS FOR DESIGN. ALL REQUIRED COMPONENTS ARE NOT SHOWN. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A FULLY FUNCTIONAL SYSTEM. 38.ALL BELOW GRADE GROUND CONNECTIONS SHALL BE MADE VIA EXOTHERMIC WELD. 39.ALL ABOVE GRADE BOND CONNECTIONS SHALL BE MADE VIA BOLTED CONNECTION, BURNDY TYPE QDA-QIKLUG. 40.ALL REQUIRED CONDUIT AND CONDUCTORS ARE NOT SHOWN. SEE SINGLE LINE DIAGRAM FOR CONDUITS AND CONDUCTORS REQUIRED FOR CONTROL AND POWER CIRCUITS. 41.PROVIDE COUNTY SIGNED INSPECTION OR PHOTO OF ALL CAD-WELDED SPLICES AND UNDERGROUND TAPS. PROVIDE GROUND TEST REPORT TO COUNTY VERIFYING COUNTERPOISE RESISTANCE IS 5 OHMS MAX. CONTRACTOR TO PROVIDE ADDITIONAL GROUNDING, IF NECESSARY, TO ACHIEVE 5 OHMS MAX. GROUND RESISTANCE. 42.EXOTHERMICALLY BOND GROUNDING JUMPERS TO COUNTERPOISE. GROUND POTENTIAL SHALL BE CONSISTENT FOR ENTIRE SITE. GROUNDING JUMPERS AND COUNTERPOISE SHALL BE #4/0 BARE COPPER. GROUND RODS SHALL BE 3/4" X 20' COPPER-CLAD GROUND RODS. EXOTHERMICALLY WELD CONNECTIONS BELOW GRADE. MECHANICALLY CONNECT CONNECTIONS ABOVE GRADE. MECHANICAL LUGS SHALL ONLY HAVE ONE WIRE LANDED IN EACH TERMINATION. EACH LUG SHALL BE FASTENED WITH A STAINLESS STEEL NUT AND BOLT. STACKING OF INDIVIDUAL LUGS WILL NOT BE ACCEPTABLE. 43.GROUND BOXES SHALL BE 14" LONG QUAZITE #PC1118CA0017 OR #PG1118BA12, INSTALL LEVEL WITH THE ADJACENT GROUND, PROVIDE 57 STONE OR MATCH SITE STONE IN BOX, WITH GROUND ROD LOCATED OFF CENTER OF BOX. QUAZITE BOX COVER TO READ "GROUND". EXPOSED GROUNDING SHALL BE IN 1" SCHEDULE 80 PVC OR LIQUID TIGHT FLEXIBLE CONDUIT. AMPERES, AMBER OR ALARM AMP HOUR OR ALARM HORN ALARM LIGHT ALARM ALARM SILIENCE RELAY AIR HANDLING UNIT AMPS INTERRUPTING CURRENT AUTOMATIC TRANSFER SWITCH AUXILIARY BATTERY BACKUP PUMP CONTROLLER BILL OF MATERIAL CIRCUIT BREAKER CONDUIT CONTROL PANEL CONTROL PANEL SURGE ARRESTOR CURRENT TRANSFORMER COPPER DISCONNECT DIGITAL OUTPUT DOUBLE POLE DOUBLE THROW DOUBLE POLE SINGLE THROW DISCONNECT SWITCH EMERGENCY CIRCUIT BREAKER EQUIPMENT GROUND ELAPSED TIME METER FUSE FAULT FLORIDA POWER AND LIGHT FLEXIBLE METALLIC CONDUIT FLOAT SWITCH GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND GALVANIZED RIGID STEEL HIGH HAND SWITCH HAND-OFF-AUTOMATIC HAND-OFF-REMOTE HUMAN MACHINE INTERFACE INDICATOR INSTRUMENTATION & CONTROL INTRUSION JUNCTION BOX LEVEL OR LOW LINE REACTOR NEUTRAL NOT TO SCALE OPEN / CLOSE OPERATOR INTERFACE TERMINAL MOTOR BREAKER MAIN CIRCUIT BREAKER MOTOR OPERATED VALVE MOTOR STARTER MOTOR STARTER OVERLOAD UTILITY POWER METER NON-FUSIBLE PRESSURE PUSHBUTTON PROGRAMMABLE LOGIC CONTROLLER PHASE PHOTOCELL PUMP CONTROL PANEL PHASE MONITOR PANEL BOARD POWER SUPPLY PUSH-TO-TEST TOTALIZER RECEPTACLE RELAY, TREND, RESISTOR REMOTE TELEMETRY UNIT SHORT CIRCUIT CURRENT RATING SHIELDED SURGE PROTECTION DEVICE SWITCH SELECTOR SWITCH SOLID STATE OVERLOAD SOLENOID VALVE TERMINAL BLOCK TIME DELAY TWISTED SHIELDED PAIR UNDERGROUND UNINTERRUPTABLE POWER SUPPLY VARIABLE FREQUENCY DRIVE TRANSFORMER POSITION A AH AL ALM ASR AHU AIC ATS AUX BAT BPC BOM C/B C CP CPSA CT CU DISC DO DPDT DPST DS ECB EG ETM F FLT FPL FMC FS GEN GFCI GND, G GRS H HS HOA HOR HMI I I&C INTR JB L LR NEUT, N NTS O/C OIT MB MCB MOV MS MSOL MTR NF P PB PLC PH, PC PCP PM PNL PS PTT Q RECPT. R RTU SCCR SHLD SPD S SS SSOL SV TB TD TSP UG UPS VFD XFMR Z MAGNETIC FLOW INDICATING TRANSMITTER PRESSURE INDICATING TRANSMITTER FLOW INDICATING TRANSMITTER FLOW ELEMENT LEVEL (FLOAT) SWITCH PRESSURE SWITCH FLOW SWITCH MOTOR OPERATED VALVE (MOV) SOLENOID VALVE (SV) SOLENOID VALVE (SV) DIAPHRAGM VALVE VOLTMETER AMMETER GROUND FAULT INTERRUPTER DRAW-OUT CIRCUIT BREAKER CIRCUIT BREAKER WITH TRIP RATING MOTOR WITH HP RATING EQUIPMENT GROUND DRIVEN ROD-TYPE GROUNDING ELECTRODE DRIVEN ROD-TYPE GROUNDING ELECTRODE WITH GROUND ACCESS WELL NON-FUSIBLE DISCONNECT SWITCH, 30A, 3P UNLESS OTHERWISE INDICATED CURRENT TRANSFORMER TRANSFORMER TRANSFORMER CONDUIT OR WIRE ROUTING; SHORT HASH MARK = PHASE CONDUCTOR LONG HASH MARK = NEUTRAL CONDUCTOR MOTOR OVERLOAD (EUTECTIC ALLOY) DUPLEX RECEPTACLE NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT LIMIT SWITCH, NORMALLY OPEN LIMIT SWITCH, NORMALLY CLOSED PRESSURE SWITCH, NORMALLY OPEN PRESSURE SWITCH, NORMALLY CLOSED FLOAT SWITCH, NORMALLY OPEN FLOAT SWITCH, NORMALLY CLOSED FLOW SWITCH, NORMALLY OPEN FLOW SWITCH, NORMALLY CLOSED TEMP. SWITCH, NORMALLY OPEN TEMP. SWITCH, NORMALLY CLOSED NORMALLY OPEN TIMED TO CLOSE CONTACT NORMALLY CLOSED TIMED TO OPEN CONTACT NORMALLY CLOSED TIMED TO CLOSE CONTACT NORMALLY OPEN TIMED TO OPEN CONTACT LIMIT SWITCH TORQUE SWITCH PRESSURE SWITCH VIBRATION SWITCH ALARM RELAY CONTROL RELAY MOTOR STARTER TIMING RELAY INDICATING LIGHT WITH COLOR NORMALLY OPEN PUSHBUTTON NORMALLY CLOSED PUSHBUTTON MAINTAINED SWITCH FUSE WITH RATING REMOTE TERMINAL POINT HORN PUMP SURGE SUPPRESSOR (PROTECTED/UNPROTECTED) FUSED LEVER-TYPE TERMINAL BLOCK WITH LED INDICATOR SP P U 1.CONTRACTOR TO DECOMMISSION ALL EXISTING ELECTRICAL EQUIPMENT AND INSTRUMENTATION AND GIVE THE MATERIAL TO THE COUNTY. ALL OTHER EQUPMENT FOR A FULLY FUNCTIONAL SYSTEM SHOWN SHALL BE PROVIDED NEW BY THE CONTRACTOR. 2.THIS PLAN SET IS GENERIC TO ALL PUMP STATION REHABS WITH THE FOLLOWING CHARACTERISTICS: ·TELEMETRY VIA DFS RADIO SYSTEM; NOT CONNECTED TO THE COUNTY FIBER COMMUNICATIONS NETWORK ·ALL 1PH, 120/240V SYSTEMS ·3PH, 208Y/120V SYSTEMS 20HP OR LESS ·3PH, 120/240V HLD SYSTEMS 25HP OR LESS ·3PH, 277Y/480V SYSTEMS 50HP OR LESS 3.CONDUIT AND CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH THE NEC AND LOCAL CODES, EXCEPT AS NOTED. 4.THE ENGINEER SHALL PROVIDE THE FOLLOWING INFORMATION: ·UTILITY TRANSFORMER KVA, SERVICE ENTRANCE PHASE AND VOLTAGE ·REQUIREMENT FOR OPTIONAL DIESEL PUMP OR STANDBY GENERATOR ·SUBMERSIBLE PUMP HP AND FLA RATINGS ·PROPOSED SITE LAYOUT WITH LOCATION SPECIFIED FOR ELECTRICAL 5.SEE PLAN SHEET NOTES FOR COMMON MAJOR BOM. 6.FOR OTHER MAJOR BOM PER ITEM NUMBER AND ID BASED ON PUMP STATION CHARACTERISTICS DEFINED BY THE ENGINEER, REFER TO: ·FIELD EQUIPMENT BOM SHT. E03 ·"PCP" CONTROL PANEL BOM SHT. E05 ·"JB-1" MOTOR JUNCTION BOX BOM SHT. E12 .5A ##1PRE-BID MEETING08/25/211 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1905Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Bill of MaterialWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-01 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1906Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Single Line Diagram with Optional Portable GeneratorWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-05 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN DIRECT READING UTILTY METER SOCKET, RINGLESS, ALUM., UG, LEVER BYPASS, SINGLE POSITION MTR #4/0 TO GROUND RING SPD PUMP CONTROL PANEL SUBMERSIBLE PUMP #1 MOTOR TERMINAL JUNCTION BOX (2) OR (3) 1/C CURRENT CARRYING AND (1) GROUNDED CONDUCTORS IN 3"C BASED ON SERVICE (1) 3" SPARE CONDUIT 2" CONDUIT SEAL-OFF (TYP. OF 2) (2) 2" U.G. CONDUIT TO WETWELL CL1, DIV2, HAZARDOUS AREA UTILITY TRANSFORMER ~ NON-HAZARDOUS AREA PCP SUBMERSIBLE PUMP CABLE (VFD-RATED) (TYP.) #4/0 TO GROUND RING FLEXIBLE VFD-RATED CABLE WITH CONTROL PAIR, 4C + 1PR/14AWG IN 2" C (TYP. OF 2) P1 P2 SUBMERSIBLE PUMP #2 UTILITY POWER 120/240, 1PH, 3W 208Y/120, 3PH, 4W 120/240 HLD, 3PH, 4W 480Y/277V, 3PH, 4W (2) OR (3) 1/C CURRENT CARRYING + EG BASED ON SERVICE (2) OR (3) 1/C CURRENT CARRYING AND (1) GROUNDED CONDUCTORS BASED ON SERVICE 7 SPD-1 (1) BELDEN 9729 IN 3/4" C PORTABLE DIESEL GENERATOR EQUIPPED WITH PORTABLE CABLES FOR: ·HIGH VOLTAGE STATION POWER ·LOW VOLTAGE POWER CABLE (AUX. LOADS) REMOTE MOUNTED EMERGENCY STOP GEN ATS AUTOMATIC TRANSER SWITCH N TO GRND RING #4/0 E L E-STOP AUX LOADS I/O 2" CONDUIT SEAL-OFFS FOR LEVEL (TYP. OF 2) DS-1 8 JB-1 SURGE PROTECTOR, 50KA, VERSION "A", CITEL MODEL M50-XXX-A BASED ON SERVICE # (2) OR (3) 1/C CURRENT CARRYING + EG BASED ON SERVICE CIRCUIT BREAKER MAIN DISCONNECT, 35KAIC MIN., LSI 3.2S, 80% RATED, SQUARE D MODEL J250DS WITH SN400LA NEUTRAL ASS'Y KIT, PKOGTH250 SERVICE GROUND KIT, PDC3JD20 PWR DIST. LUGS, AND S37450 TERMINAL SHIELD SURGE PROTECTOR, 100KA SCHNEIDER MODEL HWA BASED ON SERVICE #4/0 TO GROUND RING PNL-1 SPD 9 SPD-2 OPT. ODOR CONTROL SYSTEM 120V OR 240V, 1PH 2 20A/1P 20A 20A 20A/1P 20A/1P 20A/1P 20A/1P GENERATOR AUX LOADS LOW VOLTAGE POWER GFI RECEPTACLE (1) #12 BLK, (1) #12 WHT, (1) #10 GND IN 3/4"C 5 6 LEVEL FLOATS (TYP. OF 4) LS-1,2,3,4 2" U.G. CONDUITS TO WETWELL 1 LEVEL TRANS. LT-1 MFR'S CABLES HIGH VOLTAGE POWER RECEPT. 120VAC/20A WP GFI DUPLEX RECEPTACLE CONTROLS TO ATS CONTROLS TO PUMP CONTROL PANEL HIGH VOLTAGE PORTABLE POWER CABLE LOW VOLTAGE PORTABLE POWER CABLE HARD-WIRED PORTABLE CONTROL CABLE TO ATS AND PUMP CP (1) OMNICABLE AS11612 12/C CABLE, #16 AWG, IN 1-1/2" C GENERATOR RECEPTACLE, POST-MTD. RATING BASED ON SERVICE (SEE DETAIL) NOTES: 1.ANCHOR-SCIENTIFID ROTO-FLOAT MODEL S40NO, SUSPENDED FLOAT SWITCH, CABLE LENGTH AS REQ'D. 2.AT 240V AND BELOW "PNL-1" SHALL BE A PANELBOARD WITH PHASE AND VOLTAGE MATCHING THE INCOMING SERVICE. AT 480V, "PNL-1" SHALL BE A MINI-POWER ZONE UNIT SUBSTATION, WITH 1PH, 120/240V SECONDARY CONFIGURATION. 3.SUBMERSIBLE LEVEL TRANSMITTER, CL 1, DIV 2 AREA, WIKA MODEL LH-20 WITH CABLE, LENGTH AS REQURIED, 0-10PSI, PUR CABLE, 2-WIRE 4-20MA OUTPUT, 24VDC POWER SUPPLY, WITH OPTIONAL 316SS ADDITIONAL WEIGHT. 4.INCLUDED WITH STANDBY EQUIPMENT PACKAGE. 5.PROVIDE WIRING AND CONFIGURATION FOR GENERATOR-TO-PUMP CP SIGNALS VIA JB-2: DISCRETE: ·GEN. SHUTDOWN ALARM ·GEN. COMMON WARNING ·GEN. BATTERY CHARGER FAULT ·GEN. NOT-IN-AUTO ·GEN. FUEL TANK LOW ·GEN. FUEL TANK LEAK ·GEN. RUNNING ·EMERGENCY STOP ·UTILITY POWER AVAILABLE ANALOG: ·GEN. FUEL TANK LEVEL (%) (TSP) 5.PROVIDE WIRING AND CONFIGURATION FOR GENERATOR-TO-ATS SIGNALS VIA JB-2: ·EMERGENCY STOP ·ATS IN EMER. POSITION ·ATS IN NORMAL POS. ·UTILITY POWER AVAILABLE ·START COMMAND 6.PROVIDE WIRING AND CONFIGURATION FOR ATS-TO-PUMP CP SIGNALS ·ATS IN EMERG. POSITION 7.PROVIDE WIRING AND CONFIGURATION FOR ODOR CONTROL SYS-TO-PUMP CP SIGNALS ·ODOR CONTROL SYSTEM RUNNING (OPT.) (2) OR (3) 1/C CURRENT CARRYING + EG BASED ON SERVICE OPT. ODOR CONTROL SYSTEM SIGNALS GENERATOR CONTROLS JUNCTION BOXES (SEE DETAIL) 6 7 (1) OMNICABLE AS11606 6/C CABLE, #16 AWG, IN 1" C JB-2 (1) OMNICABLE AS11612 12/C CABLE, #16 AWG, IN 1-1/2" C + (1) TSP 4 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1907Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) METER PANELBRD GRADE DS-1 MTR JB-1 6' MAX. TO HIGHEST BREAKER HANDLEMAIN DISC. 6" X 6" X 10' CONCRETE POST, EMBEDDED (TYP.) 5' MIN 6' MAX STAINLESS STEEL, N3R JUNCTION BOX WITH TERMINAL STRIP MOUNTED WITH ALUMINUM BACKING PLATE. TERMINAL STRIPS TO HAVE STAINLESS STEEL SCREWS, HINGED ON BOTTOM. SEE DETAIL. PUMP CONTROL PANEL 2'-6" MIN.SPD-1 4" THICK CONCRETE SURROUNDING CONCRETE POSTS (TYP.) AUTOMATIC TRANSFER SWITCH LONG SLOTTED STANDARD 1-5/8" x 1-5/8" STRUT CHANNEL, 304 SS, 12-GA WITH 316SS FASTENER HARDWARE (TYP.) SPD-2 SQUARE D MINI-POWER-ZONE OR NQ PANELBOARD BASED ON SERVICE VOLTAGE GENERATOR RECEPTACLE (SEE DETAIL) 6" X 6" X 10' CONCRETE POST, EMBEDDED (TYP.) DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN Electrical Plans Equipment Layout with Optional Generator & Single Door EnclosureWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-08 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1908Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) LOCK UNLOCK LOCK UNLOCK DC CONTROL DEVICES POWER CONTROL DEVICES AC CONTROL DEVICES A/C UNIT A/C UNIT 28 INTRUSION SWITCH #2 Electrical Plans PCP Pump Control Panel Equipment Layout - Single DoorWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-10 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN NOTES: 1.12" DEEP SINGLE-DOOR ENCLOSURES SHALL BE PROVIDED FOR: ·3PH, 208Y/120V SYSTEMS 10HP OR LESS (WITH FVNR MOTOR STARTERS) ·3PH, 120/240V HLD SYSTEMS 10HP OR LESS (WITH FVNR MOTOR STARTERS) ·3PH, 480V SYSTEMS 15HP OR LESS (WITH FVNR MOTOR STARTERS) SINGLE DOOR, 48"H x 36"W x 12"D, N3R, 304SS, SUNSHIELDS ON ALL SIDES WITH WELDED 1.5-2" STANDOFFS, 304SS PADLOCKABLE 3-PT LATCH HANDLE, ALUMINUM DEADFRONT, POWDER-COATED WHITE, VENT DRAIN, AND 304SS DOOR STOP. 2.20" DEEP SINGLE-DOOR ENCLOSURES SHALL BE PROVIDED FOR: ·ALL 1PH, 120/240V SYSTEMS (WITH VFD'S) SINGLE DOOR, 48"H x 36"W x 20"D, N3R, 304SS, SUNSHIELDS ON ALL SIDES WITH WELDED 1.5-2" STANDOFFS, 304SS PADLOCKABLE 3-PT LATCH HANDLE, ALUMINUM DEADFRONT, POWDER-COATED WHITE, VENT DRAIN, AND 304SS DOOR STOP. 3.SCHAEFFER P/N SPP-4836 SUBPANEL FOR 48 x 36 ENCLOSURE 4.CONTROL PANEL INTERRUPTING CAPACITY SHALL BE RATED MINIMUM 25 KAIC. # 1 2OR 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1909Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans PCP Pump Control Panel Single Line Diagram with FVNR StartersWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-12 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN MB-1 MCB ECB GENERATOR RECEPTACLE GR MB-2 MS-1 PDB A B C N 1 2 5 MOTOR DISCONNECT TO PUMP P1 TO PUMP P2 5 MOTOR DISCONNECT MSOL-1 3 MS-1 FVNR MOTOR CONTACTOR MSOL-1 F1,2 120VAC, 1PH F3 CONTROL TRANSFORMER 1500VA, 208x230x460V - 115V (3-PHASE SERVICE ONLY) XFMR-1 F4,5,6 DFS RTU 3 FROM DS-2 OR ATS 120/240, 1PH, 3W + GND 208Y/120, 3PH, 4W + GND 120/240 HLD, 3PH, 4W + GND 480Y/277V, 3PH, 4W + GND 4 4 NOTES: 1.POWER DISTRIBUTION BLOCK, 1-POLE, 760A, SQUARE D MODEL NSYEBCP27628. # 1 SOLID STATE OVERLOAD CLASS 20 FVNR MOTOR CONTACTOR SOLID STATE OVERLOAD CLASS 20 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1910Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans PCP Pump Control Panel SchematicWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-14 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN 120VAC 1 PHASE INTERIOR LIGHT GFI DIN-MTD DUPLEX RECEPT. FAN SPD-PNL 15A 120V/1PH SURGE PROTECTOR L1 FAN GFI NOTES: 1.MINI. CIRCUIT BREAKER, 120V, 10A/1P, UL 489, SQUARE D MODEL 60110. 2.MINI. CIRCUIT BREAKER, 120V, 15A/1P, UL 489, SQUARE D MODEL 60112. 3.PANEL LIGHT, LED, SCHAEFFER MODEL 21220. 4.GFI DUPLEX RECEPTACLE, DIN-MTD, 15A, PHOENIX MODEL 5600462. 5.PANEL SURGE PROTECTOR, 15A, 120V, PHOENIX MODLE 2920683. 6.THERMAL/SEAL FAIL RELAY, 24VDC, FLYGT MINI-CAS II, MODEL 83-58-57/14-40-70-97. 7.ALARM LIGHT, PIPE MOUNTED, INGRAM PRODUCTS MODEL CTO15FR. 8.INSTALL FAN & VENT IF NOT EQUIPPED WITH AIR CONDITIONER # CB-10 10A CB-11 L2 INTERIOR LIGHT (DOUBLE DOOR) 3 3 4 5 SCHAEFFER PF-43000/PFA-40000 120VAC, 169CFM, N3R, SS 8 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1911Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans PCP Pump Control Panel Schematic - FVNRWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-15 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN NOTES: 1.100 K-OHM RESISTORS REQUIRED FOR 480V POWER P/N DFS-00271-008-07. 2.NO CONNECTION FOR 240V 1PH POWER. 3.INTRUSION SWITCH, SQUARE D MODEL 9007MS01S0200. 4.TRANSCEIVER CONTROLLER UNIT, DFS TACPAC TCU MODEL 00367-008-00, DFS TCU INSTALLTION KIT MODLE 00392-008-09, POLYPHASER ANTENNA KIT DFS MODEL 00392-008-01 5.BATTERY, SLA, 12VDC, 18AH, POWERSONIC MODEL PW-PS12180F2 # 1 1 2 3 5 4 ANALOG1+(C1) 22 WETWELL LEVEL GENERATOR FUEL TANK LEVEL (OPT.) SP-1 SP-2 24VDC - + GENERATOR Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1912Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans PCP Pump Control Panel Schematic - VFD or GeneratorWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-17 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN DFS REMOTE I/O RIO032 120V INCOMING POWER P4-1 P4-2 POWER 120 VAC PS-1 12V/5A POWER SUPPLY MODBUS P4-3 RS-485 (B) P4-4 RS-485 (A) P5-2 RS-485 (B) P5-1 RS-485 (A) 150 P5-3 RS-485 (GND) DFS TAC PACK TCU 507 510 511 518 519 CB-12 NOTES: 1.MINI. CIRCUIT BREAKER, 120V, 6A/1P, UL 489, SQUARE D MODEL 60107. 2.POWER SUPPLY, 12V, 5ADC, PHOENIX TRIO MODEL 2866475. 3.EXPANSION MODULE, (8)DI, (8)DO, (8)AI, (8)AO, DFS P/N RIO032. # 1 2 3 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1913Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans PCP Pump Control Panel Schematic - GeneratorWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-19 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN GENERATOR BATTERY CHARGER FAULT GEN P1-1 DI-01 P1-2 DI-02 P1-3 DI-03 P1-4 DI-04 P1-5 DI-05 P1-6 DI-06 P1-7 DI-07 P1-8 DI-08 P1-9 DI GND GENERATOR NOT IN AUTO GENERATOR COMMON WARNING GENERATOR SHUTDOWN ALARM GENERATOR RUNNING DISCRETE INPUTS (SINKING) DFS REMOTE I/O RIO032 603 605 608 610 613 615 618 620 623 GENERATOR FUEL TANK LOW ATS IN EMERG. POSITION GENERATOR FUEL TANK LEAK GEN GEN GEN GEN GEN GEN GEN JB-2 Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1914Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) LT-1, LS-1,LS-2, LS-3,LS-4 FROM WETWELL P1,P2 FROM WETWELL LT-1, LS-1,LS-2, LS-3,LS-4 TO PCP P1,P2 TO PCP JB-1 CONTROL SIGNALS FROM ATS IN CONDUIT CONTROL SIGNALS TO/FROM GENERATOR JB-2 CONTROL SIGNALS TO PUMP CONTROL PANEL IN CONDUIT COMPRESSION CONNECTOR FOR FUTURE PORTABLE CORDS JB-1 BILL OF MATERIAL ITEM TAG QTY PART NUMBER DESCRIPTION Manufacturer 1 JB-1 1 A20H1608SSLP ENCLOSURE, 16"H x 20"W x 8"D, N4X, 304SS HOFFMAN21A20P16ENCLOSURE SUB PANEL, 17" x 13", STEEL 3 6 NSYEBCD12611 ENCLOSED TERM. BLK, COPPER, DIN, 200A SQUARE D4MISC.NSYTRAC22, NSYTRAABV35 TERMINAL END BARRIER, END CLAMPS 5 18 NSYTRV42 TERMINAL, 1-PT, 600V, 32A 6 3 PKOGTA2 EQUIPMENT GROUNDING KIT JB-2 BILL OF MATERIAL ITEM TAG QTY PART NUMBER DESCRIPTION Manufacturer 1 JB-2 1 A16H1206SSLP ENCLOSURE, 12"H x 16"W x 6"D, N4X, 304SS HOFFMAN21A16P12ENCLOSURE SUB PANEL, 13" x 9", STEEL 3 MISC.NSYTRAC22, NSYTRAABV35 TERMINAL END BARRIER, END CLAMPS SQUARE D427NSYTRV42TERMINAL, 1-PT, 600V, 32A NOTES 1.ALL CONDUIT PENETRATIONS FROM BOTTOM. 2.PANEL SHALL BE PADLOCKABLE, HINGED AT BOTTOM. 3.SEAL OFF FITTINGS SHALL BE MOUNTED ON THE CONTROL PANEL SIDE OF CIRCUIT. Electrical Plans JB-1 Pump Junction Box ArrangementWastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaE-20 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 1" = 2' Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1915Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Detail #1Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaED-01 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN FENCE POST/GATE BONDING DETAIL NOT TO SCALE CONCRETE FOUNDATION MASONRY ANCHOR GROUND CLAMP FINISH GRADE FENCE POST #2 SOLID TINNED COPPER JUMPER CABLE,GREEN INSULATION TYPICAL FOR BOTH SIDES OF GATES. TOGROUND ROD GATEFRAME GROUND CLAMP #2 SOLID TINNED COPPER GROUND CONDUCTOR GATE POST 3/4"x20' COPPER-CLAD GROUND ROD ERICO P/N 613400 & P/N CC34, OR EQ. GROUND TEST WELL DETAIL NOT TO SCALE 24" MIN.FINISHED GRADE MATCH SITE STONE #4/0 BARE COPPER GROUND CABLE (TYP.) 3/4"x20' COPPER-CLAD GROUND ROD EXOTHERMICALLY CONNECT, ERICO CADWELD, OR EQ.3" MIN.12" MIN.COMPACTED BACKFILL TO COUNTERPOISE TO SERVICE RATED DISCONNECT GROUND MAT DETAIL NOT TO SCALE BUS LUGS EQUIP. GROUND #4/0 BARE COPPER (TYP.) (TYP. OF 4) TO COUNTERPOISE3/4"X20' COPPER-CLAD GROUND ROD, SEE GROUND ROD TEST WELL DETAIL (TYP.) NOTES: 1.ADDITIONAL CONCENTRIC RINGS SHALL BE ADDED AS REQUIRED TO MEET THE FIVE (5) OHM (OR LESS) SPECIFIED RESISTANCE. EACH RING TO HAVE FOUR (4) GROUND RODS MIN. AND SPACED TEN (10) FEET FROM THE INNER RING. 18"9.5" 22"13.5"12"OLDCASTLE NO. 37-T CAST IRON HEAVY DUTY TRAFFIC COVER MARKED "GROUND" OLDCASTLE MB37 CONCRETE BOX 12"x20"x12" OLDCASTLE NO. 37 BODY Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1916Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Detail #2Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaED-02 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN 12'-0" #4 DOWELS @ 12" C/C X:1'-0"GENERATOR (SLAB/REINF.)8"(3)#4 CONT.1 1 #4 @ 12" O/C, EW, TOP & BOTTOM 1'-6"T.O. CONC 100 YEAR FLOOD EL. NOTE: CONTRACTOR SHALL PROVIDE A 3/8" CLOSED CELL NEOPRENE PAD ON THE SLAB TO MATCH THE BASE FOOTPRINT OF THE GENERATOR OR THE DIESEL PUMP. 6'-0" 8" GRANULAR, FREE DRAINING SAND UNDER SLAB, COMPACTED TO (98% MODIFIED PROCTOR) ASTM D1557 1 1 1'-6"8"8"#5@12" O/C, EW, MID-DEPTH #5@12" O/C, EW BROOM FINISH 6" FREE-DRAINING, CLEAN GRANULAR MATERIAL COMPACT SUBGRADE TO A DENSITY OF 95% PER ASTM D-1557 (MODIFIED PROCTOR) 1" 132" SLOPED CONCRETE PAD SLOPED CONCRETE EQUIPMENT PAD 11'-0" STRUCTURAL NOTES: 1.ALL CONCRETE SHALL BE 4000 PSI MINIMUM COMPRESSIVE STRENGTH; W/C = 0.45, AIR CONTENT 6% (±) 1%; SLUMP = 4" BEFORE ADDING WATER REDUCING AGENT. 2.ALL STEEL SHALL BE ASTM A615, GR 60. 3.ALL DIMENSIONS SHOWN ARE TYPICAL ONLY. CONTRACTOR TO VERIFY OVERALL SLAB SIZE WITH EQUIPMENT MANUFACTURER AND ENGINEER PRIOR TO CONSTRUCTION. 4.ALL SLABS SHALL HAVE TOOLED EDGES ON ALL SIDES8'-0"FIN GR. #5 AT 12" EW, CENTER PLAN 6'-0"4'-0"6"PROFILE T.O. CONC 100 YEAR FLOOD EL. T.O. CONC 100 YEAR FLOOD EL 2" TO 6"3/8" NEOPRENE PAD SEE SHEET D-01 1 1PRE-BID MEETING08/25/21Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1917Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) Electrical Plans Detail #3Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaED-03 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 AS SHOWN TOWER REINFORCED CONCRETE FOUNDATION REINFORCED DETAIL #3 20' x 3/4" COPPER GROUND ROD TOWER SECTION TO CONTROL PANEL (SEE CONDUIT DETAIL) GROUND LEVEL DETAIL #1 BAND-IT STAINLESS STEEL TIE WRAPS 21' x 1-1/4" SCH 80 GALVANIZED POLE ANTENNA COAXIAL CABLE DETAIL #2 GALVANIZED PIPE CAP NUT SLEEVE DETAIL #1 POLE SWIVEL BOLT SIDE VIEW 21' POLE REINFORCED BOTTOM OF TOWER NECK 3/8" STAINLESS STEEL NUT 3/8" STAINLESS STEEL BOLT 1" x 6" PVC NIPPLE TOWER AXIS AND PIER 1" PVC CONDUIT SET DIRECTLY IN FRONT OF LEFT TOWER LEG CONDUIT DETAIL TOP VIEW SECTION A-A 1" STRAIN RELIEF ON TOP OF STUBBED CONDUIT 1" CONDUIT MOUNTED IN FRONT OF TOWER LEG AS SHOWN IN CONDUIT DETAIL 21' POLE REINFORCED DETAIL #2 COAXIAL MOUNTING AND ROUTING 18" ANTENNA REINFORCED HEATSHRINK COAXIAL CONNECTION HERE ALIGN TOP ANTENNA LOBE WITH TOP OF TOWER COAXIAL CABLE SERVICE LOOP BAND-IT STAINLESS STEEL TIE WRAP #6 SOLID COPPER GROUND TO RTU GROUND LUG GROUND ROD REINFORCED BONDED TO GROUND RINGDETAIL #3 GROUNDING DETAIL GROUND CLAMP TEARDROP GROUND LUG #6 COPPER GROUND WIRE21'-0"3'-0"MINIMUM1-1/2"1'-6" (TYP)CONCRETE BASE. SIZE TO BE DETERMINED BY LICENSED STRUCTURAL ENGINEER PER SOIL CONDITIONS AND FLORIDA BUILDING CODE WIND LOAD REQUIREMENTS (SEE NOTE 1) NOTES 1.TOWER/ANTENNA ASSEMBLY AND FOUNDATION CONSTRUCTION MUST MEET CURRENT EDITION FLORIDA BUILDING CODE WIND LOAD REQUIREMENTS. PROVIDE STRUCTURAL CERTIFICATION BY FLORIDA REGISTERED LICENSED PROFESSIONAL ENGINEER. Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1918Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se) HIGH VOLTAGE RECEPTACLE WITH REVERSE INTERIOR, C-H #AJA1 ANGLE ADAPTER, AND C-H #AJ71 BACK BOX WITH 2-1/2" NPT HUB, 200A C-H AREA203226-S22, 480VAC, 3W, 4P OR C-H AREA204226-S22, 230VAC, 2W, 3P PER ELECTRICAL SERVICE TO PUMP CONTROL PANEL 6" SQ. CONCRETE POST, EMBEDDED GRADE 2-1/2" ALUM. CONDUIT TO U.G. ALUM. SWEEP SS UNISTRUT AND HARDWARE (TYP.) 5'-0" 2'-6" MIN. GRADE TO PUMP CONTROL PANEL 4" THICK SURROUNDING CONCRETE POST 2'-0" MIN. 11 3'-0" 1 Electrical Plans Detail #4Wastewater Pump StationRepair and RenovationPump Station 121.02Collier County, FloridaED-04 DATE: PROJECT NO. FILE NO. SCALE: SHEET NUMBERREVISIONSNO. DESCRIPTION DATEJOHNSON ENGINEERING, INC. 2122 JOHNSON STREET P.O. BOX 1550 FORT MYERS, FLORIDA 33902-1550 PHONE: (239) 334-0046 E.B. #642 & L.B. #642 AUGUST 12, 2021 20149700-198 05-48-25 SIDE VIEW FRONT VIEW GENERATOR RECEPTACLE POST MOUNTED 1" = 10'NOTES 1.PORTABLE GENERATOR ONLY. SEE DETAIL. Date: Reviewed and Approved For: ROW PRROW20210308627 8/3/2023 16.C.4.dPacket Pg. 1919Attachment: 4. WD#1 US Water Services Corporation (27285 : Recommendation to approve Change Order No. 1, under Purchase Order No. 4500215169 with U.S. Water Se)