Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Backup Documents 11/14/2023 Item #17B
i 7 B ORIGINAL DOCUMENTS CHECKLIST & ROUTING SLIP TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT TO THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGNATURE Print Iin pink paper. ,kttach to original document. The completed routing slip and original documents are to he forwarded to the County Attorney Office at the time the item is placed on the agenda. MI completed routing slips and original documents must he received in the County kttorney Mee no later than NIMIdis).preceding the Board meeting. **NEW**ROUTING SLIP Complete routing Imes 41 through*2 as appropriate for additional signatures.dates,and/or information needed, If the document is already complete with the exception of the Chairman's signature,draw a line through routing lines ii I through#2,complete the checklist,and fin-ward to the County Attorney Office Route to Addressee(s)(List in routing order) Office Initials Date ...„. 2. 3 County Attorney Office County Attorney Office /, . H t ,,,,1 ( ,... .,. i I -I 3 L/ ) 4. BCC Office Board of County Commissioners Rt.btAist 117isi2 3 . ' 5. Minutes and Records Clerk of Court's Office M F II-lb-2'3 PRIMARY CONTACT INFORMATION Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the addressees above,may need to contact staff for additional or missing information. Name of Primary Staff Ray Bellows,Laura DeJohn Phone Number 739-75/-2463 Contact I Department (MD Agenda Date Item was November 14,2023 Agenda Item Number 178 Approved by the BCC . I pe of Document Ordinance Number of Original 1 Attached Documents Attached , PO number or account number if document is to be recorded INSTRUCTIONS & CHECKLIST Initial the Yes column or mark"N/A" in the Not Applicable column,whichever is Yes NIA(Not appropriate. (Initial) Applicable) .. I. Does the document require the chairman's original signature? LD 2. Does the document need to be sent to another agency for additional signatures? If yes, N/A provide the Contact Information(Name;Agency;Address: Phone)on an attached sheet. 3. Original document has been signed/initialed for legal sufficiency. (All documents to be LD signed by the Chairman,with the exception of most letters,must be reviewed and signed by the Office of the County Attorney. 4. All handwritten strike-through and revisions have been initialed by the County Attorney's NIA Office and all other parties except the BCC Chairman and the Clerk to the Board 5. The Chairman's signature line date has been entered as the date of BCC approval of the LD document or the final negotiated contract date whichever is applicable. . 6. "Sign here"tabs are placed on the appropriate pages indicating where the Chairman's LD signature and initials are required. ,. 7. In most cases(some contracts are an exception),the original document and this routing slip LD should be provided to the County Attorney Office at the time the item is input into SIRE. Some documents are time sensitive and require forwarding to Tallahassee within a certain time frame or the BCC's actions are nullified. Be aware of your deadlines! S. The document was approved by the BCC on 11-14-23 and all changes made during '7 r I triffai the meeting have been incorporated in the attached document. The County N\\ ' -- Attorney's Office has reviewed the changes,if applicable. V " tbigliCiet. 9, Initials of attorney verifying that the attached document is the version approved by the , I ' , N BCC,all changes directed by the BCC have been made,and the document is ready for the Chairman's signature. ' ' I;Corms/County Forms/BCC Forms;Original Documents Routing Slip WWS Original 9,03,04,Revised 1.26,05,Revised 2 24.05,Revised 1130/12 176 ORDINANCE NO. 2023- 52 AN ORDINANCE OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AMENDING ORDINANCE NUMBER 2022-13, THE GOLDEN GATE GOLF COURSE MIXED-USE PLANNED UNIT DEVELOPMENT (MPUD), BY LIMITING THE USES ON THE 6.16± ACRE RESIDENTIAL TOURIST (RT) TRACT TO ALLOW HOTEL/MOTEL OR TIMESHARE OR MULTI-FAMILY OR COMMERCIAL USES; TO CHANGE THE ALLOWED MULTI-FAMILY USE ON THE RESIDENTIAL TOURIST (RT) TRACT TO A MAXIMUM OF 215 RENTAL UNITS; TO REDUCE THE MINIMUM FLOOR AREA PER MULTI-FAMILY RENTAL DWELLING UNIT TO 250 SQUARE FEET ON THE RT TRACT SUBJECT TO THE OCCUPANCY STANDARDS IN ORDINANCE NO. 2004-58, AS AMENDED; TO PROVIDE 22.8 % [49 UNITS] OF THE MULTI-FAMILY RENTAL UNITS ON THE RT TRACT WILL BE RENTED TO HOUSEHOLDS WHOSE INCOME QUALIFIES FOR AFFORDABLE HOUSING WITH 24 UNITS AT 80% OR LESS THE AREA MEDIAN INCOME FOR COLLIER COUNTY AND 25 UNITS AT 100% OR LESS THE AREA MEDIAN INCOME FOR COLLIER COUNTY, ALL SUBJECT TO CORRESPONDING RENT LIMITS; AND THE REMAINING 77.2% [166 UNITS] WILL BE RENTED-RESTRICTED AT A RENT PERMITTED FOR HOUSEHOLDS WHOSE INCOME IS UP TO 120% OF AREA MEDIAN INCOME FOR COLLIER COUNTY. THE PROPERTY IS LOCATED ON THE SOUTHWEST CORNER OF GOLDEN GATE PARKWAY AND COLLIER BOULEVARD IN SECTION 27, TOWNSHIP 49 SOUTH, RANGE 26 EAST, COLLIER COUNTY, FLORIDA CONSISTING OF 171.6± ACRES; AND BY PROVIDING AN EFFECTIVE DATE. (PL202300012392) WHEREAS, On April 6, 2022, the Board of County Commissioners approved Ordinance No. 2022-13, which created the Golden Gate Golf Course Mixed-Use Planned Unit Development ("MPUD"); and WHEREAS, D. Wayne Arnold, AICP, of Q. Grady Minor& Associates, P.A. and Richard D. Yovanovich, Esq., representing STYX Holdings Development, LLC, petitioned the Board of County Commissioners to amend the PUD. NOW THEREFORE, BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA that: [23-CPS-02372/1818295/1151 1 of 2 Golden Gate Golf-RT PUDA 10-20-23 178 SECTION ONE: Exhibits "A"through "F", attached to Ordinance No. 2022-13 are hereby amended and replaced with Exhibits "A" through "F", attached hereto and incorporated by reference herein. SECTION TWO: This Ordinance shall become effective upon filing with the Department of State and on the date that the Growth Management Plan Amendment in Ordinance No. 2023 -5 3 becomes effective. PASSED AND DULY ADOPTED by super-majority yote of the Board of County Commissioners of Collier County,Florida,this j1/4-Phday of NOVei vi 2023. ATTEST BOARD OF COUNTY COMMISSIONERS CRYSTAL K. KINZEL, CLERK COLLIER COUNTY, FLORIDA By: if SAlkek PC Attest as to&airman's 'Deputy Clerk Rick LoCastro, Chairman L signature only Approved as to form and legality: Thls ordinaries filed with the Secretary of t9i-e's OffAt. the 'L Iv, L A 112 day of d-U ocknowledginnen* cif that Heidi Ashton-Cicko 10-20-23 fiing received his L day Managing Assistant County Attorney or Nt Attachments: Exhibit A - Permitted Uses Exhibit B Development Standards Exhibit C - Master Plan Exhibit D . Legal Description Exhibit E Requested Deviations from LDC Exhibit F Developer Commitments [23-CPS-02372/1818295/1151 2 of 2 Golden Gate Golf-RT RUDA 10-20-21 I78 EXHIBIT A LIST OF PERMITTED USES Regulations for development of this PUD shall be in accordance with the contents of this document and all applicable sections of the Growth Management Plan (GMD), the Land Development Code (LDC), and the Administrative Code in effect at the time of approval of the first Site Development Plan (SDP)or plat. Where the PUD ordinance does not provide development standards, then the provision of the specific sections of the LDC that are otherwise applicable shall apply. MAXIMUM INTENSITY/DENSITY: This MPUD shall be limited to the following: Residential Tract: 400 residential dwelling units Commercial Tract: 30,000 SF Public Use Tract: 75,000 SF government facilities and 120 group housing units* Community Facility Tract: 120 group housing units* Golf Course Tract: Subject to limitations in E and F below Residential Tourist Tract: One of the following scenarios may be developed in the RT Tract: a. A maximum of 158 hotel/motel units and up to b. A maximum of 98 time sharotimeshare or 215 multi-family rental dwelling units c. A maximum of 60,000 SFsquare feet of C-3 commercial uses *A maximum of 75,000 SF government facilities and 120 group housing units shall be permitted for the overall PUD. The uses are subject to a trip cap identified in Exhibit F of this MPUD. Residential development, within the Residential Tract, is subject to an Affordable Housing Agreement between the Developer and Collier County. No building or structure, or part thereof, shall be erected, altered or used, or land used, in whole or in part,for other than the following: A. RESIDENTIAL TRACT-PRINCIPAL USES: 1. Multi-Family residential dwelling units 2. Leasing offices B. RESIDENTIAL TRACT-ACCESSORY USES: 1. Customary accessory uses and structures, such as but not limited to, a clubhouse, pavilions, community gardens and courtyards for residents and their guests. 2. Water management facilities. 3. Indoor and outdoor recreational facilities and uses for residents and their guests, such as but not limited to greenways, swimming pools, playgrounds, and tennis courts. 4. Community center,for residents and their guests 5. Retail services that serve as an integral part of the multi-family development and for residents only, such as a coffee shop,yoga studio or market. 6. Greenways Words underlined are added;words 1t-titrangh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 1 of 20 17g C. PUBLIC USE TRACT—PRINCIPAL USES: 1. Administration of Public Health, Veteran's Affairs, Environmental Quality, Land and Wildlife Conservation, Housing, Urban Planning and Community Development (9431 — 9451, 9511—9532, 9611—9651) 2. Administrative Service Facilities, General Government Services (9199) 3. Essential services, as defined by the LDC 4. Library 5. Museum 6. Park,Open Space and Recreational Uses, including golf courses and greenways 7. Park and Recreational Service Facilities 8. Property Appraiser Office(9311) 9. Safety Service Facilities 10. Group housing, compliance with 5.05.04 of the LDC, subject to FAR of.60 (see Exhibit E, Deviation#4). D. PUBLIC USE TRACT—ACCESSORY USES: 1. Accessory uses and structures that are incidental to the principal uses permitted in the Public Use Tract. 2. Greenways 3. Water management facilities E. GOLF COURSE TRACT—PRINCIPAL USES: 1. Golf Course 2. Hiking trails, walkways, multi-use paths and observation decks 3. Passive recreational uses F. GOLF COURSE TRACT—ACCESSORY USES: 1. Uses and structures that are incidental to uses listed in the Golf Course Tract. 2. Recreational facilities that serve as an integral part of the golf course, including but not limited to clubhouse, community center, driving range, shuffleboard courts, swimming pool,tennis facilities, snack shops and restrooms. 3. Pro shops with equipment sales, no greater than 1,000 square feet,associated with a golf course. 4. Water management, as allowed by the LDC. 5. Restaurants and driving range, associated with a golf course, 350 seats limited to the restaurant and bar area and provided that the hours of operation are no later than 12:00 a.m. Amplified indoor sound shall be permitted during business hours. The facility is subject to the Collier County Noise Ordinance. 6. Maintenance facilities and buildings. 7. Greenways Words underlined are added;words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 2 of 20 178 G. COMMERCIAL TRACTS—PRINCIPAL AND ACCESSORY USES: Parcel A: All permitted principal and accessory uses listed within the C-3 'Commercial Intermediate Zoning District'. Parcel B:All permitted principal and accessory uses listed within the C-4'Commercial General Zoning District'. H. COMMUNITY FACILITY USE TRACT—PRINCIPAL USES 1. Group Housing, compliance with 5.05.04 of the LDC, subject to FAR of.60 (see Exhibit E, Deviation #4), including nursing and personal care facilities(8051—8059) 2. Non-residential uses including: a. Essential services b. Parks, open space and recreational uses c. Childcare centers d. Community facility uses such as schools, libraries, safety service facilities, and community centers. e. Communication and utility facilities 3. Any other principal use,which is comparable in nature with the foregoing list of permitted principal uses, as determined by the Board of Zoning Appeals ("BZA") or the Hearing Examiner by the process outlined in the LDC. I. COMMUNITY FACILITY USE TRACT—ACCESSORY USES: 1. Accessory uses and structures that are incidental to the principal uses permitted in the Community Facility Use District. 2. Medical doctor offices, rehabilitation facilities 3. Indoor and outdoor recreational facilities 4. Cafeterias and restaurants for use of residents and guests only. 5. Greenways 6. Water management, as allowed by the LDC. J. RESIDENTIAL TOURIST TRACT—PRINCIPAL USES 1. Multi-family rental dwelling units 2. Hotels, motels 3. Time share facilities 4. C-3, Commercial Intermediate Zoning District permitted uses 5. Any other principal use,which is comparable in nature with the foregoing list of permitted principal uses, as determined by the Board of Zoning Appeals ("BZA") or the Hearing Examiner by the process outlined in the LDC. K. RESIDENTIAL TOURIST TRACT—ACCESSORY USES: 1. Accessory uses and structures that are incidental to the principal uses permitted in the Residential Tourist and C-3'Commercial Intermediate' Zoning Districts. Words underlined are added;words t uc' gh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 3 of 20 2. Shops, personal service establishments, eating or drinking establishments, dancing and staged entertainment facilities, meeting rooms and auditoriums, where such uses are an integral part of an apartment hotel, hotel or motel. 3. Leasing office Words underlined are added;words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 4 of 20 176 EXHIBIT B LIST OF DEVELOPMENT STANDARDS The standards for land uses within the development shall be as stated in these development standards tables. Standards not specifically set forth herein shall be those specified in applicable sections of the LDC in effect as of the date of approval of the SDP or subdivision plat. TABLE I PUBLIC USE TRACT DEVELOPMENT STANDARDS PRINCIPAL USES ACCESSORY USES MINIMUM LOT AREA 10,000 square feet N/A MINIMUM LOT WIDTH 100 feet N/A MINIMUM YARDS(EXTERNAL) From Golden Gate Parkway*1 0 feet 0 feet 50 feet average, however no From Abutting Residential Properties 100 feet less than 35 feet at any one location From Greenways 0 feet 0 feet MINIMUM YARDS(INTERNAL) Internal Drives 10 feet 10 feet (Measured from back of curb) Lakes(measured from the Lake 5 feet 5 feet Maintenance Easement) MINIMUM DISTANCE BETWEEN STRUCTURES 10 feet 10 feet MAXIMUM HEIGHT Zoned I 45 feet 35 feet Actual 55 feet 45 feet MINIMUM FLOOR AREA(FIRST FLOOR) 1,000 square feet N/A *1 All projects providing a front yard setback greater than zero feet must accommodate pedestrians, bicyclists, or be designed with a combination of planting, seating and hardscaped areas. Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added; words strttelf-th-ro-ugh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 5 of 20 TABLE II RESIDENTIAL TRACT DEVELOPMENT STANDARDS PRINCIPAL USES ACCESSORY USES MINIMUM LOT AREA N/A N/A MINIMUM LOT WIDTH N/A N/A MINIMUM LOT DEPTH N/A N/A MINIMUM SETBACKS From Collier Boulevard 25 feet 15 feet 50 feet average, From Abutting Residential (Western Tract Boundary) *1 80 feet however no less than 35 feet at any one location From Southern PUD Boundary 25 feet — 10 feet From Greenway 0 feet 0 feet From Internal Drives (Measured from the back of curb) 15 feet _ 15 feet From Lakes(measured from the Lake Maintenance Easement) 0 feet 0 feet MINIMUM DISTANCE BETWEEN STRUCTURES 20 feet 10 feet MAXIMUM HEIGHT Multi-Family: Zoned 45 feet 35 feet Actual 55 feet 45 feet Multi-Family for Seniors: Zoned 85 feet 35 feet Actual 95 feet 45 feet MINIMUM FLOOR AREA(PER UNIT) 600 square feet N/A Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added; words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 6 of 20 I 7 8 TABLE III GOLF COURSE TRACT DEVELOPMENT STANDARDS PRINCIPAL USES ACCESSORY USES MINIMUM LOT AREA N/A N/A MINIMUM LOT WIDTH N/A N/A MINIMUM LOT DEPTH N/A N/A MINIMUM SETBACKS*2 From Collier Boulevard 0 feet 50 feet 50 feet average, From Western PUD Boundary 0 feet however no less than 35 feet at any one location From Southern Golf Course Tract Boundary 0 feet 50 feet From Northern Golf Course Tract Boundary 0 feet 50 feet From Greenway 0 feet 0 feet From Internal Drives(Measured from the back of curb) 0 feet 0 feet From Lakes (measured from the Lake Maintenance Easement) 0 feet 5 feet MINIMUM DISTANCE BETWEEN STRUCTURES MAXIMUM HEIGHT*1 Zoned 35 feet 35 feet Actual 45 feet 45 feet MINIMUM FLOOR AREA N/A N/A *1 Netting and supporting infrastructure for golf driving range are exempt from maximum height limitations listed above but will not exceed 200 feet. Non-parking lot lighting for the driving range will be limited to 60' in height. *2 Clubhouse, maintenance building, driving range, restaurants and pro shop uses shall be a minimum of 50 feet from external residential uses. Pitch and chip practice area and putting greens are not subject to the 50 foot setback. Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added;words t r•e' ' are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 7 of 20 1 ? 8 TABLE IV COMMERCIAL TRACT DEVELOPMENT STANDARDS PRINCIPAL USES ACCESSORY USES MINIMUM LOT AREA N/A N/A MINIMUM LOT WIDTH N/A N/A MINIMUM LOT DEPTH N/A N/A MINIMUM SETBACKS From Collier Boulevard *1 25 feet 20 feet From Golden Gate Parkway*1, 2 20 feet 20 feet From Western Tract Boundary 15 feet 15 feet From Northern Golf Course Tract Boundary 0 feet 0 feet From Internal Drives(Measured from the back of curb) 10 feet 0 feet From Lakes(measured from the Lake Maintenance Easement) 0 feet 0 feet MINIMUM DISTANCE BETWEEN STRUCTURES MAXIMUM HEIGHT Zoned 35 feet 35 feet Actual 45 feet 35 feet MINIMUM FLOOR AREA 1,000 SF 1,000 SF *1 All projects providing a front yard setback greater than zero feet must accommodate pedestrians, bicyclists,or be designed with a combination of planting, seating and hardscaped areas. *2 Parcel B—Zero foot front yard setback Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added;words slc—through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 8 of 20 178 TABLE V COMMUNITY FACILITY TRACT DEVELOPMENT STANDARDS PRINCIPAL USES ACCESSORY USES MINIMUM LOT AREA N/A N/A MINIMUM LOT WIDTH N/A N/A MINIMUM LOT DEPTH N/A N/A MINIMUM SETBACKS From Collier Boulevard 25 feet 20 feet From Western PUD Boundary *1 100 feet 50 feet From Northern Golf Course Tract Boundary 0 feet 0 feet From Greenway 0 feet 0 feet From Internal Drives (Measured from the back of curb) 10 feet 0 feet From Lakes(measured from the Lake Maintenance Easement) 0 feet 0 feet MINIMUM DISTANCE BETWEEN STRUCTURES MAXIMUM HEIGHT Zoned 35 feet 35 feet Actual 45 feet 35 feet MINIMUM FLOOR AREA 1,000 SF 1,000 SF *1 Non-Golf Course Uses permitted within the Greenway in accordance with LDC Section 5.05.15 H.2 shall have an average 50 foot setback from abutting residential zoned property and no less than 35 feet at anyone location. Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added;words t-ue' h are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 9 of 20 TABLE VI RESIDENTIAL TOURIST TRACT DEVELOPMENT STANDARDS HOTEL/MOTEL/TIMESHARE/ COMMERCIAL USES *3 MULTI-FAMILY USES *3 PRINCIPAL ACCESSORY PRINCIPAL ACCESSORY MINIMUM LOT AREA 1 Acre N/A 10,000 SF N/A MINIMUM LOT WIDTH 150 feet N/A 75 feet N/A MINIMUM LOT DEPTH N/A N/A N/A N/A MINIMUM SETBACKS From Golden Gate Parkway*1 20 feet 10 feet 25 feet 25 feet From Internal PUD Boundary 0 feet 0 feet 0 feet 0 feet From Southern Golf Course Tract Boundary*2 0 feet 0 feet 0 feet 0 feet From RT Zoned Property 15 feet 0 feet 15 feet 15 feet From Internal Drives (Measured from the back of curb) 10 feet 0 feet 10 feet 10 feet MINIMUM DISTANCE BETWEEN STRUCTURES N/A N/A 10 feet 10 feet MAXIMUM HEIGHT Zoned*4 100 feet or 10 N/A 50 feet 50 feet stories MINIMUM FLOOR AREA*5 1,000250 SF N/A 700 SF N/A *1 All projects providing a front yard setback greater than zero feet must accommodate pedestrians, bicyclists, or be designed with a combination of planting,seating and hardscaped areas. *2 Golf course tract boundary is not considered a front yard. *3 If redevelopment occurs on the Residential Tourist Tract, with uses permitted within the C-3 zoning district,then the C-3 development standards will be applicable. *4 If developed with more than 98 rental dwelling units the height shall be reduced to a zoned height of 60 feet and an actual height of 75 feet. *5 Pursuant to Section 6 Paragraph 13 of Ordinance No.2004-58 as amended and as codified in of the Code of Laws and Ordinances,the minimum unit size for a Multi-family dwelling unit is 250 square feet New hotel/motel/timeshare units shall comply with the minimum size requirements in county ordinances. Note: Nothing in this PUD document shall be deemed to approve a deviation from the LDC unless it is expressly stated in a list of deviations. Words underlined are added;words struck-thr-o-tigh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 10 of 20 17 & Yid 01 LL CLOL/St/C 0MQ'2tl-0119IM0(3 CL-1tl0000\S0NIMtl210\10vo1111 00 00 CZ-1C0000\ONINNYId- fos\ON NNYd\'0 CC W J N U. cc EC >¢ < < D .o 0 Ucn .,. ma AVM)2bd 3JV N C700 Ng V � d � � O ~ dZ i. /e, - Z 4.1 • ' 4� I� £-JSi a3NOZ1•.: U• ' 7� ❑1. . JZ -I o Zroa , • fA ' • MS3nt1F115Z:.' U um c.i❑: N mz Lt wgw C.y X0-> M ❑ LLJ Z w J Q m W¢ w N w w I r1f ( H2 a V' �' '} © a zYaa. / = o0 w � 0 a c•,•• 6U3 ' ' Q W W 3 • •\ �ojZ I-w O V �Z � a Z q o' w E •'\ rii�' r i b C� F Z = (' \�� o . 0 N '� `\ • L Y C7i 1 ,� - �.Q v`� oN w.cn(.9 1•• . � • \ �i s w E M uwiv.a •, N 'iW gN WJL 9n Woo �� ce �i j ]U cD ElJ • -a MT. ¢,,: V `:`�� 0 o a W co >, • w O _J 'C } • p �, f �;Z N❑ E ? s N g Q Z Q 1 9 w Zi ,11ggf l > • N • •, 0' Q v s • i F- •tO W H H,:i MS -Id H16Z V M WW a •. : qN p w JW� w < m Z1— ' y J. w0 Z JO LLI wf— ¢ chv) cc cc 1 I•. Q .4. /' � � U > O w cn ¢ ' •, 2 1"' Z } Q W cK m m O 81 i.' —U Z !i cn • U Wn = CO w i'.« ¢ W i wiW 0O m < W a 0 N •• . ww 0 • Dco UI Z W Q (9 O I-= I. H 0 : D .• Z Z I ~w w 0 > Q /I • as U OeK ZZJ i•. wU co W OZWO 0 Q Z t . >awUC . O 0OU Z p Z w H :•. I. Z Z1iZQW • W w wp I• `- og WJZ < a W w I : a O ) Ww Q O � i ; WU 7a p >Z 0 < W W I— n t iN iw HEll J ® ViCO in.0 J • rN 0 178 WV OG L Czoz/zz/8 OM c-o 11OWX3 fz-18DODD\soNIMv O\13 1 1N DO OD Cz-1>JODDO\ONINNVId- road\CNINNVId\O (n o -§, W d'-V1A W W U' 0 h LL1 CV n rn Z I-W Z rx Q CC D � oN W - 0_ W d scpr zN W' W Z 0 0 CC v Udct 5 rI W ( _z W U` ry ~ -m C.) Z Z o co�M W W 0 W O W' wzw I- CC W U) = Q 0 o�cn m Z U' W W z w r1 i0 W' : 0 W U w cn X cn 1 Y ct CO ►W- a 2 a W W u. in H H >- W m fx W P D W C- m F- Z Z q 0 U) N - ' Q D U 0 W LU U U U m Q C� ~ z < z w a 0 J J O O O O O ? H W m *`- 2 0 O O O O O 0 f w J X W 0 I W U) = Li 0 I _, D W Z Z Z Z Z H CO Z viE 0 0 0 0 0 0 z Q o0 O `� ZUU U CC W U Z o 0 a U U C 4 W W W W W p w w D N U Q (n (n (n co (n N 0 J . LL 0 Z_ c > 0 w 2 O C U) 0 W ( ( %) Z > < U D N 2 0 (-- N r "4 LL• O W a Q u ,? O2 Cn W' ° CO _J U 0 QOWO � DIi Z ' '' 4 0 aZ 'rH cc < 0 c.. q co a 2ONW '- H O cn w o H OWpu tiw 0 = T Ln w W '" 0 W QOWCL 0 ucc m 0 U) 2 Z2Ca z o 0 O M Hz W ] a D a O zWtnOww0 W N UW U' > Z � D � pF- fn ~ 0or :_ >- zoDz � = o w � Q o C° a - 0 � in p o (n U ii ii Z r- rn o < W W o "^a z U ui W cn W W W W H W Q' U � +1 -- W < 0505 -1000 I- 0 � FD- ° M a+l N M I f O p O 0 O 2 2 2 W � �- Z 0 0 a cc < - O J a < ,- Q pM V ti a m 2 2 Z - 0 Z a s +i Al < a +1 +1 +1 2 2 2 D H >< x } Q Q d F- d Q > 222 � 0 <Im0 Li w - 1- Z > U H o w w 0 0 z D J 0 w LaL W H F- 0 O 1 C.) O .(2, ¢ W ccQD t- r v) Hw ry Q �} W J ti � � jr uJJJ n > 0H - n0 CC UO W ciin Z >- CC Q J L CC z Z D O I- w H 0 Q w zzZ � OCWn wW OVU ¢ Qw } ¢ 2 oww www d W WZZO Ow 000 03 OF- U ~ H D ac0 wCC0 cn f 0 W U U `" O W 0 D O Q Z O Z Z 2 - D > O D > 2 J D m J O20Un W W UDW X w00 a00 col- a O W W 0 D O 0 z 0 - 2 0 a Z W W W W W W F 1- 0CCCt0O- O OWDOW 2 wWm CC 10 , wwWm I— cni I- 0WmOW Q 0 I- Z 178 EXHIBIT D LEGAL DESCRIPTION BEING A PORTION OF BLOCK 1,AND ALL OF TRACT"A",AND TRACT"B",GOLDEN GATE UNIT 1,PLAT BOOK 5, PAGES 60 THROUGH 64, ALL OF TRACT "A" GOLDEN GATE UNIT 8 PART 1, PLAT BOOK 5, PAGES 147 THROUGH 151,AND A PORTION OF TRACT"A", GOLDEN GATE UNIT 8 PART 2, PLAT BOOK 9, PAGES 107A THROUGH 112,ALL OF THE PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGIN AT THE NORTHEAST CORNER OF TRACT "A", GOLDEN GATE UNIT 1, PLAT BOOK 5, PAGES 60 THROUGH 64, PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA,THE SAME BEING A POINT ON THE WEST RIGHT-OF-WAY OF COLLIER BOULEVARD;THENCE ALONG SAID RIGHT-OF-WAY,SOUTH 00°28'56" EAST,A DISTANCE OF 5,145.44 FEET TO THE SOUTHEAST CORNER OF TRACT "A", GOLDEN GATE UNIT 8 PART 1, PLAT BOOK 5, PAGES 147 THROUGH 151, PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA; THENCE ALONG THE BOUNDARY OF SAID TRACT "A" FOR THE FOLLOWING SIX (6) COURSES AND DISTANCES, 1) SOUTH 87°55'11"WEST,A DISTANCE OF 335.06 FEET;2)THENCE NORTH 00°29'07"WEST,A DISTANCE OF 258.71 FEET TO A POINT ON A CURVE TO THE LEFT; 3)THENCE NORTHWESTERLY 79.93 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 50.00 FEET,A CENTRAL ANGLE OF 91°35'35",(CHORD BEARING NORTH 46°16'54"WEST,A DISTANCE OF 71.69 FEET);4)THENCE SOUTH 87°55'09"WEST,A DISTANCE OF 233.53 FEET; 5)THENCE NORTH 00°29'07"WEST, A DISTANCE OF 1,294.31 FEET TO A POINT ON A CURVE TO THE LEFT; 6) THENCE NORTHWESTERLY 335.72 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET, A CENTRAL ANGLE OF 91°35'44", (CHORD BEARING NORTH 46°17'01" WEST, A DISTANCE OF 301.09 FEET)TO A POINT ON THE BOUNDARY OF TRACT"A", GOLDEN GATE UNIT 8 PART 2, PLAT BOOK 9, PAGES 107A THROUGH 112 OF SAID PUBLIC RECORDS; THENCE ALONG SAID BOUNDARY FOR THE FOLLOWING SEVENTEEN (17)COURSES AND DISTANCES, 1)SOUTH 87°55'09"WEST,A DISTANCE OF 1,404.72 FEET TO A POINT ON A NON TANGENTIAL CURVE TO THE LEFT; THENCE NORTHERLY 282.64 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 712.77 FEET,A CENTRAL ANGLE OF 22°43'13", (CHORD BEARING NORTH 12°07'31" WEST, A DISTANCE OF 280.79 FEET); 2) THENCE NORTH 23°29'07" WEST, A DISTANCE OF 994.26 FEET; 3) THENCE NORTH 66°30'53" EAST, A DISTANCE OF 600.00 FEET; 4) THENCE SOUTH 23°29'07" EAST, A DISTANCE OF 543.32 FEET TO A POINT ON A CURVE TO THE LEFT; 5) THENCE SOUTHEASTERLY 556.70 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 465.00 FEET, A CENTRAL ANGLE OF 68°35'44", (CHORD BEARING SOUTH 57°47'00" EAST, A DISTANCE OF 524.05 FEET); 6) THENCE NORTH 87°55'09" EAST, A DISTANCE OF 655.68 FEET TO A POINT ON A CURVE TO THE LEFT; 7) THENCE NORTHEASTERLY 324.02 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET,A CENTRAL ANGLE OF 88°24'14", (CHORD BEARING NORTH 43°43'02" EAST,A DISTANCE OF 292.82 FEET); 8)THENCE NORTH 00°29'07" WEST, A DISTANCE OF 661.52 FEET TO A POINT ON A CURVE TO THE LEFT; 9) THENCE NORTHWESTERLY 219.91 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET, A CENTRAL ANGLE OF 60°00'00", (CHORD BEARING NORTH 30°29'07" WEST, A DISTANCE OF 210.00 FEET); 10)THENCE NORTH 60°29'07"WEST,A DISTANCE OF 715.08 FEET TO A POINT ON A CURVE TO THE LEFT; 11)THENCE WESTERLY 194.26 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET,A CENTRAL ANGLE OF 53°00'00", (CHORD BEARING NORTH 86°59'05" WEST,A DISTANCE OF 187.41 FEET); 12)THENCE SOUTH 66°30'53"WEST,A DISTANCE OF 600.52 FEET TO A POINT ON A CURVE TO THE LEFT; 13)THENCE SOUTHERLY 329.86 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET,A CENTRAL ANGLE OF 90°00'00", (CHORD BEARING SOUTH 21°30'51" WEST,A DISTANCE OF 296.98 FEET); 14)THENCE SOUTH 23°29'07" EAST,A DISTANCE OF 100.00 FEET; 15)THENCE SOUTH 66°30'53" WEST, A DISTANCE OF 600.00 FEET; 16)THENCE NORTH 23°29'07" WEST, A DISTANCE OF 25.00 FEET TO A POINT ON A CURVE TO THE RIGHT; 17)THENCE NORTHERLY 487.72 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 1,215.00 FEET, A CENTRAL ANGLE OF 23°00'00", (CHORD BEARING NORTH 11°59'06" WEST, A DISTANCE OF 484.45 FEET); THENCE ALONG SAID BOUNDARY AND THE PROLONGATION THEREOF, NORTH 00°29'07" WEST, A DISTANCE OF 1,665.00 FEET TO THE Words underlined are added;words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 13 of 20 178 NORTHWEST CORNER OF TRACT "B", GOLDEN GATE UNIT 1, PLAT BOOK 5, PAGES 60 THROUGH 64, OF SAID PUBLIC RECORDS;THENCE ALONG THE BOUNDARY OF SAID TRACT"B" FOR THE FOLLOWING FOUR (4) COURSES AND DISTANCES, 1) NORTH 89°30'53" EAST,A DISTANCE OF 605.00 FEET; 2)THENCE SOUTH 00°29'07" EAST, A DISTANCE OF 475.00 FEET TO A POINT ON A CURVE TO THE LEFT; 3) THENCE SOUTHEASTERLY 329.87 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET, A CENTRAL ANGLE OF 90°00'00",(CHORD BEARING SOUTH 45°29'07" EAST,A DISTANCE OF 296.98 FEET)TO A POINT ON THE BOUNDARY OF TRACT "A" OF THE AFOREMENTIONED GOLDEN GATE UNIT 8 PART 2; THENCE ALONG SAID BOUNDARY, NORTH 89°30'53" EAST, A DISTANCE OF 510.00 FEET TO A POINT ON THE BOUNDARY OF TRACT "A" OF THE AFOREMENTIONED GOLDEN GATE UNIT 1, THE SAME BEING A POINT ON A CURVE TO THE LEFT; THENCE ALONG SAID BOUNDARY FOR THE FOLLOWING THREE (3) COURSES AND DISTANCES, 1) NORTHEASTERLY 329.87 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 210.00 FEET, A CENTRAL ANGLE OF 90°00'00", (CHORD BEARING NORTH 44°30'53" EAST, A DISTANCE OF 296.98 FEET); 2) THENCE NORTH 00°29'07" WEST, A DISTANCE OF 475.00 FEET; THENCE NORTH 89°30'53" EAST, A DISTANCE OF 893.76 FEET TO THE NORTHWEST CORNER OF GOLF CREST OF NAPLES, A CONDOMINIUM, OFFICIAL RECORDS BOOK 779, PAGE 358 OF SAID PUBLIC RECORDS;THENCE ALONG THE BOUNDARY OF SAID GOLF CREST OF NAPLES FOR THE FOLLOWING SEVEN (7) COURSES AND DISTANCES, 1) SOUTH 33°25'57" EAST, A DISTANCE OF 101.54 FEET; 2)THENCE SOUTH 07°30'43" WEST, A DISTANCE OF 242.09 FEET; 3) THENCE SOUTH 67°56'47" EAST, A DISTANCE OF 49.29 FEET; 4)THENCE NORTH 89°30'13" EAST,A DISTANCE OF 138.41 FEET; 5)THENCE NORTH 00°29'07"WEST,A DISTANCE OF 190.41 FEET;6)THENCE NORTH 12°46'13" EAST,A DISTANCE OF 60.02 FEET;7)THENCE NORTH 00°29'07" WEST,A DISTANCE OF 94.98 FEET TO A POINT ON THE NORTH LINE OF THE AFOREMENTIONED TRACT"A" OF SAID GOLDEN GATE UNIT 1;THENCE ALONG SAID NORTH LINE FOR THE REMAINING TWO(2)COURSES AND DISTANCES, 1) NORTH 89°30'53" EAST, A DISTANCE OF 89.50 FEET; 2) THENCE SOUTH 75°29'07" EAST, A DISTANCE OF 80.23 FEET TO THE POINT OF BEGINNING. LESS AND EXCEPT PARCEL BEING THE LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 4098, PAGE 3967 AND PAGE 1131, PAGE 1230 ALSO BEING A PORTION OF TRACT "A", GOLDEN GATE UNIT 8 PART 2, PLAT BOOK 9, PAGES 107A THROUGH 112,ALL OF THE PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE NORTHWEST CORNER OF TRACT "A", GOLDEN GATE UNIT 8, PART 2, PLAT BOOK 9, PAGES 107A THROUGH 112, PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA; THENCE ALONG THE WEST LINE OF SAID TRACT"A",SOUTH 00°29'07" EAST,A DISTANCE OF 649.27 FEET;THENCE NORTH 89°30'53" EAST, DEPARTING SAID WEST LINE A DISTANCE OF 336.31 FEET TO A POINT ON THE BOUNDARY OF THE LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 1131, PAGE 1230, OF SAID PUBLIC RECORDS AND THE POINT OF BEGINNING OF THE PARCEL OF LAND HEREIN DESCRIBED; THENCE ALONG THE BOUNDARY OF SAID LANDS FOR THE FOLLOWING TWO(2)COURSES AND DISTANCES, 1) NORTH 03°16'23" EAST, A DISTANCE OF 183.92 FEET; 2)THENCE NORTH 10°35 02 EAST, A DISTANCE OF 113.36 FEET TO A POINT ON THE BOUNDARY OF THE LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 4098, PAGE 3967 OF SAID PUBLIC RECORDS; THENCE ALONG THE BOUNDARY OF SAID LANDS FOR THE FOLLOWING FIVE (5) COURSES AND DISTANCES, 1) NORTH 00°44'11" WEST, A DISTANCE OF 16.91 FEET; 2)THENCE NORTH 12°22'36" EAST, A DISTANCE OF 31.94 FEET TO A POINT ON A CURVE TO THE LEFT; 3) THENCE NORTHERLY 78.51 FEET ALONG THE ARC OF SAID CURVE, HAVING A RADIUS OF 577.88 FEET, A CENTRAL ANGLE OF 07°47'03", (CHORD BEARING NORTH 08°29'05" EAST,A DISTANCE OF 78.45 FEET);4) THENCE NORTH 89°15'56" EAST, A DISTANCE OF 89.59 FEET; 5) THENCE SOUTH 00°44'11" EAST, A DISTANCE OF 116.40 FEET TO AN INTERSECTION WITH THE NORTH LINE OF THE AFOREMENTIONED LANDS DESCRIBED IN OFFICIAL RECORDS BOOK 1131, PAGE 1230 OF SAID PUBLIC RECORDS;THENCE ALONG THE BOUNDARY SAID LANDS FOR ALL OF THE REMAINING COURSES AND DISTANCES, NORTH 89°15'49" EAST, A DISTANCE OF 86.04 FEET;THENCE SOUTH 47°36'49" EAST,A DISTANCE OF 196.55 FEET;THENCE SOUTH Words underlined are added;words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20,2023) Page 14 of 20 l7� 23°14'36"WEST,A DISTANCE OF 104.18 FEET;THENCE SOUTH 00°38'10" EAST,A DISTANCE OF 75.04 FEET; THENCE SOUTH 89°25'14"WEST, A DISTANCE OF 331.54 FEET TO THE POINT OF BEGINNING. RESULTING PARCEL CONTAINING 171.81 ACRES, MORE OR LESS. Words underlined are added;words struck through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 15 of 20 178 EXHIBIT E LIST OF DEVIATIONS Deviation#1: Relief from LDC Section 4.07.02 B.2 PUD"Design Requirements,"which requires PUDs to provide landscape buffers along the perimeter of PUD boundaries, to instead require no hedge or wall within the landscape buffers where the greenway is located. Deviation#2: Relief from LDC Section 4.06.02 A"Landscape Buffers," which requires landscape buffers between separate land uses,to instead allow no landscape buffers between separate land uses internal to the PUD. Deviation#3: Relief from LDC Section 4.05.04 G "Parking Space Requirements,"to allow a reduction in requirement of off-street parking spaces for consistency with the Golden Gate Parkway Overlay District and to meet actual parking demands. This includes: a. No additional off-street parking required for outdoor dining/seating areas for restaurants. b. If the subject property is within 330' of an improved public transit facility, such as a bus shelter, bus transfer facility, or park and ride site, the required number of off- street parking spaces shall be reduced by 10 percent. c. The affordable housing development shall have the option to reduce the number of off-street parking spaces by 10 percent. d. Parking for hotel uses may be shared with adjacent commercial properties under separate ownership, consistent with the previously approved parking agreement recorded in OR Book 2090, Page 1194.The parking agreement shall remain valid even if the RT parcel is redeveloped. Deviation#4: Relief from LDC Section 5.05.04 D.1.,"Group Housing",which requires the maximum floor area ratio (FAR) shall not exceed 0.45 to instead allow an FAR of 0.60 for Group Housing uses within the PUD. Deviation#5: FOR RT TRACT ONLY: Relief from LDC Section 4.05.04, Table 17, Parking Space requirements for multi-family dwellings,which requires: All units shall have 1 parking space per unit plus visitor parking computed at 0.5 per efficiency unit, 0.75 per 1-bedroom unit, and 1 per 2-bedroom or larger unit. Office/administrative buildings shall have parking provided at 50 percent of normal requirements. Where small-scale recreation facilities are accessory to a single-family or multifamily project and intended only for the residents of that project, exclusive of golf courses/clubhouses, the recreation facilities may be computed at 50 percent of normal requirements where the majority of the dwelling units are not within 300 feet of the recreation facilities and at 25 percent of normal requirements where the majority of the dwelling units are within 300 feet of the recreation facilities. To instead allow parking to be provided at a ratio of 1 parking space per unit, with no requirement to provide additional parking for the leasing office or for recreation facilities. Words underlined are added;words true gh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 16 of 20 17 EXHIBIT F LIST OF DEVELOPMENT COMMITMENTS The purposed of this Section is to set forth the development commitments for the development of this project. 1. GENERAL A. One entity (hereinafter the Managing Entity) shall be responsible for PUD monitoring until close-out of the PUD, and this entity shall also be responsible for satisfying all PUD commitments until close-out of the PUD. At the time of this PUD approval, the Managing Entity is Collier County. Should the Managing Entity desire to transfer the monitoring and commitments to a successor entity,then it must provide a copy of a legally binding document that needs to be approved for legal sufficiency by the County Attorney. After such approval, the Managing Entity will be released of their/its obligations upon written approval of the transfer by County staff, and the successor entity shall become the Managing Entity. As Owner and Developer sell off tracts, the Managing Entity shall provide written notice to County that includes an acknowledgement of the commitments required by the PUD by the new owner and the new owner's agreement to comply with the Commitments through the Managing Entity, but the Managing Entity shall not be relieved of its responsibility under this Section. When the PUD is closed-out, then the Managing Entity is no longer responsible for the monitoring and fulfillment of PUD commitments. B. Issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law." (Section 125.022, FS) C. All other applicable state or federal permits must be obtained before commencement of the development. D. Lights shall be shielded to avoid light spillage into other properties. E. At the time of Plat or Site Development Plan (SDP)the applicant shall provide errant golf ball netting or other engineering solution for development in the Golf Course Tract limited to the Golf Course and Driving Range. This shall include signed and sealed engineering drawings including but not limited to proposed location layout plans, errant golf ball devise design, and details to insure no golf balls exit the Golf Course Tract. 2. TRANSPORTATION A. The maximum total daily trip generation for the PUD(excluding RT Tract)shall not exceed 687 two-way PM peak hour net trips based on the use codes in the ITE Manual on trip generation rates in effect at the time of application for SDP/SDPA or subdivision plat approval. Words underlined are added;words struelk-through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 17 of 20 1 ? 8 B. The maximum total daily trip generation for the RT Tract shall not exceed 234 two-way PM peak hour net trips based on the use codes in the ITE Manual on trip generation rates in effect at the time of application for SDP/SDPA or subdivision plat approval. C. To promote walkability, pedestrian connectivity shall be provided between land uses and Collier Boulevard and Golden Gate Parkway. Pedestrian access from the Greenway Tract shall be provided to the "Residential", Public Use",and "Community Facility" project development tracts. D. 4± acres along the eastern MPUD boundary shall be reserved for future Collier Boulevard right-of-way improvements. E. Existing access points for the Commercial and RT Tracts on Golden Gate Parkway shall remain until each site is redeveloped. 3. ENVIRONMENTAL A. TREE PRESERVATION A total of 2,285 trees were found to meet Collier County's tree count criteria, in accordance with LDC Section 3.05.07; therefore, requiring a minimum tree preservation of 571 trees (2,285 existing trees x 25% = 571). Per LDC Section 3.05.07 A.2, trees which die shall be replaced with 10-foot high native canopy trees on a one for one basis. Total tree count for the MPUD= 571 trees Per LDC Section 5.05.15 G.2.e, existing trees shall be preserved and retained within the greenways, or within the golf course, at a minimum ratio of 1 canopy tree per every 2,000 square feet of greenway provided. The total Greenway area provided is 16.45±-acres(716,562 SF);therefore, requiring a total of 358 canopy trees to be retained and/or provided within the greenways (716,562 SF/2,000 SF = 358). The vegetation will be provided concurrent with development of each tract abutting the greenway. B. Best management practices shall be utilized for any use that may store hazardous materials. C. Prior to site clearing activities for each tract, the development footprint will be surveyed for potential listed plant and animal species. If listed species are determined to be present a management plan shall be provided in accordance with agency guidelines. 4. AFFORDABLE HOUSING A. The developer of the Residential Tract has agreed to construct up to 400 rental dwelling units for residents in income and rental ranges as approved by the Collier County Board of County Commissioners in the accompanying Developer Agreement. B. If the Residential Tourist Tract is developed with more than 98 multi-family rental dwelling units,the following shall apply: Words underlined are added; words are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 18 of 20 1. Forty-nine (49) units (collectively referred to as "Set Aside Units") shall be restricted as follows: a. Twenty-four (24) units shall be rented to households whose incomes are up to and including 80% of the Area Median Income (AMI) for Collier County and the corresponding rent limits. b. Twenty-five (25) units shall be rented to households whose incomes are up to and including 100%of the AMI for Collier County and the corresponding rent limits. 2. There will be no income restrictions on the remaining units on the Residential Tourist Tract. However, the remaining units will be rent restricted at a rent equal to or less than rents permitted for households whose incomes are up to and including 120%of the AMI for Collier County. These rent restrictions will be committed for a period of 30 years from the date of issuance of certificate of occupancy of the first unit. Rent limits may be adjusted annually based on the rent limit table published by the Florida Housing Finance Corporation of the U.S. Department of Housing and Urban Development. 3. The Set Aside Units shall be committed for a period of 30 years from the date of issuance of certificate of occupancy of the first Set Aside Unit. Income and rent limits may be adjusted annually based on combined income and rent limit table published by the Florida Housing Finance Corporation or as otherwise provided by Collier County. 4. Initial preference to Set Aside Units shall be given to Essential Service Personnel (ESP). a. ESP means natural persons or families at least one of whom is employed as police or fire personnel, a childcare worker, a teacher or other educational personnel, health care personnel, or public employee. b. Initially,each Set Aside Unit will be held vacant and advertised for ESP for a minimum of 90 days prior to the issuance of a certificate of occupancy. In the event that no ESP rents the available Set Aside Unit, then the unit may also be offered to the general public (non-ESP) but shall remain a Set Aside Unit and be rent and income restricted accordingly. After the initial offering of a unit, no preference will be given to ESP. However, when a unit becomes available advertising as set forth in paragraph (c) below shall be provided. c. At a minimum,advertising will consist of provided written notice to the Collier County Community and Human Services Division and the human resource departments for local hospitals, the Collier County Public School District, Collier County Government, other municipalities within Collier County, all EMS and fire district, and the Collier County Sheriff's Office. 5. As part of the annual PUD monitoring report,the developer will include an annual report that provides the progress and monitoring of occupancy of the income restricted units. For rent restricted units, rent rolls and rental data will be provided in a format approved by Collier County Community and Human Services Division. Developer agrees to annual on-site monitoring by the County. Words underlined are added; words struck eugh are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 19 of 20 5. UTILITIES A. The Owner shall convey a County Utility Easement (CUE) and declaration of restrictions of CUE to the Collier County Water-Sewer District for infrastructure through the property. The CUE and declaration of restrictions of CUE shall be 30 feet in width and shall extend from a point on Collier Boulevard (CR 951) to the northwest corner of the PUD. The CUE and declaration of restrictions of CUE shall be shown on any final subdivision plat and shall be conveyed in accordance with the Collier County Utilities Standards and Procedures Ordinance, free and clear of all liens and encumbrances, within six months of the effective date of this PUD Ordinance. The declaration of restrictions of CUE will be binding on future owners. 6. LANDSCAPING A. Landscape buffers adjacent to Golden Gate Parkway shall only be required for the Commercial and RT Tracts upon redevelopment of each parcel. 7. GREENWAY A. The passive recreation uses within the Greenway shall be identified at the time of plat or site development plan approval for each conversion project. Such uses may include, open space, nature trails, a park, playground, exercise equipment, and multi-use paths or other passive recreational uses that were vetted at the Stakeholder Outreach Meetings or approved by the Board of County Commissioners. B. The lighting and building or structure setbacks within the Greenway are subject to LDC section 5.05.15 H. Design Standards, however,the minimum average 50-foot setback and no less than 35 feet at any one location from lands zoned residential shall not apply to the shared common tract line between the Greenway tract and any internal conversion project development tract. The setbacks requirements are applicable to the shared common tract line between the Greenway tract and existing surrounding lands zoned residential. C. The County shall be the maintenance entity for the Greenway until such time the Board of County Commissioners elects to assign its responsibility to another entity. At the time of subdivision plat approval, the Greenway shall be recorded as a tract of land along with a recorded restrictive covenant and greenway maintenance easement over the conversion project development tracts, where applicable. Words underlined are added; words Vic-through are deleted. Golden Gate Golf Course MPUD-RT Tract PL20230012932 (October 20, 2023) Page 20 of 20 FLORIDA DEPARTMENT Of STATE RON DESANTIS CORD BYRD Governor Secretary of State November 21, 2023 Crystal K. Kinzel, Clerk of Court Office of the Clerk of the Circuit Court & Comptroller of Collier County 3329 Tamiami Trail E, Suite #401 Naples, FL 34112 Dear Ms. Kinzel, Pursuant to the provisions of Section 125.66, Florida Statutes, this will acknowledge receipt of your electronic copy of Collier County Ordinance No. 2023-52, which was filed in this office on November 16, 2023. If you have any questions or need further assistance, please contact me at(850) 245-6271 or Anya.Owens@DOS.MyFlorida.com. Sincerely, Anya C. Owens Administrative Code and Register Director ACO/wlh R. A. Gray Building • 500 South Bronough Street • Tallahassee, Florida 32399-0250 Telephone: (850) 245-6270