Loading...
Agenda 07/25/2023 Item #16A 2 (Hacienda Lakes - Final acceptance of portable water and sewer)16.A.2 07/25/2023 EXECUTIVE SUMMARY Recommendation to approve final acceptance and accept the conveyance of the potable water and sewer utility facilities for Esplanade at Hacienda Lakes Phase 3, PL20190000415, and authorize the County Manager, or designee, to release the Final Obligation Bond in the total amount of $4,000 to the Project Engineer or the Developer's designated agent. OBJECTIVE: To have the Board of County Commissioners, as Ex-Officio Governing Board of the Collier County Water -Sewer District, approve final acceptance and accept the conveyance of these potable water and sewer facilities and to release the Final Obligation Bond in the total amount of $4,000, in accordance with the Collier County Utility Standards and Procedures, Ordinance No. 2004-31. CONSIDERATIONS: 1) The Developer of Esplanade at Hacienda Lakes Phase 3 has constructed the potable water and sewer facilities within dedicated easements to serve this development. (See attached location map). The potable water and sewer facilities were offered for conveyance to the County, as described in O.R. Book 5640, Page 1334, and are located within County utility easements dedicated by the plat of Esplanade at Hacienda Lakes Phase 3, recorded in Plat Book 64, Pages 20-23, of the Public Records of Collier County, Florida. 2) Preliminary acceptance of these utility facilities was approved by the Development Review staff on June 11, 2019. At that time, the value of these potable water and sewer utility facilities (assets) was $91,560.77 and $82,942.58, respectively. 3) Staff recorded all final acceptance documents associated with the facilities being conveyed to the County in the public records of Collier County, which were reviewed and approved by the County Attorney's office as to form and legality. The County acquired its interest in the potable water and sewer facilities by Utilities Facilities Warranty Deed and Bill of Sale recorded in O. R. Book 5640, on page 1334 ("the Utilities Facilities Deed"). 4) The potable water and sewer utility facilities have been operated and maintained during the required one (1) year warranty period, following preliminary acceptance. 5) A final inspection to discover defects in materials and workmanship was conducted by the Development Review staff on June 8, 2023, in coordination with Public Utilities and these facilities have been found to be satisfactory and acceptable. 6) Staff recommends final acceptance of the subject utility facilities and to release the Final Obligation Bond in the total amount of $4,000. Staff also recommends acceptance of the Utilities Facilities Deed and the facilities described therein. 7) This final acceptance is in accordance with Collier County Ordinance No. 2004-31, as amended. 8) Staff is unaware of any issues that would serve to negate the recommendation to release the applicable security. FISCAL IMPACT: Approval of this Executive Summary will result in the Collier County Water -Sewer District receiving title to the utility facilities, which at the time of preliminary acceptance, had a total gross value of $174,503.35 (no depreciation applied) and an asset will be recorded in the financial records of the county. GROWTH MANAGEMENT IMPACT: There is no growth management impact associated with this action. LEGAL CONSIDERATIONS: This item has been approved as to form and legality and requires a majority vote Packet Pg. 79 16.A.2 07/25/2023 for Board approval. -DDP RECOMMENDATION: To approve final acceptance and accept the conveyance of the potable water and sewer utility facilities for Esplanade at Hacienda Lakes Phase 3, PL20190000415, accept the conveyance of the Utilities Facilities Deed and the facilities described therein, and to authorize the County Manager, or designee, to release the Final Obligation Bond in the total amount of $4,000 to the Project Engineer or the Developer's designated agent. Prepared by: Lucia S. Martin, Project Manager I, Development Review Division ATTACHMENT(S) 1. Location Map (PDF) 2. Exhibit A (PDF) 3. Assets Sheet (PDF) 4. Warranty Deed and Bill of Sale (PDF) 5. Plat Map (PDF) Packet Pg. 80 16.A.2 07/25/2023 COLLIER COUNTY Board of County Commissioners Item Number: 16.A.2 Doc ID: 25785 Item Summary: Recommendation to approve final acceptance and accept the conveyance of the potable water and sewer utility facilities for Esplanade at Hacienda Lakes Phase 3, PL20190000415, and authorize the County Manager, or designee, to release the Final Obligation Bond in the total amount of $4,000 to the Project Engineer or the Developer's designated agent. Meeting Date: 07/25/2023 Prepared by: Title: Technician — Development Review Name: Lucia Martin 06/08/2023 11:20 AM Submitted by: Title: Environmental Specialist — Growth Management Community Development Department Name: Jaime Cook 06/08/2023 11:20 AM Approved By: Review: Wastewater Steve Nagy Additional Reviewer Completed 06/08/2023 11:52 AM Water Howard Brogdon Additional Reviewer Completed 06/08/2023 12:54 PM Engineering and Project Management Craig Pajer Additional Reviewer Completed 06/08/2023 1:18 PM Water Pamela Libby Additional Reviewer Completed 06/08/2023 1:50 PM Wastewater Robert Von Holle Additional Reviewer Completed 06/08/2023 3:03 PM Development Review Marcus Berman Additional Reviewer Completed 06/09/2023 5:41 AM Operations & Regulatory Management Michael Stark Additional Reviewer Completed 06/12/2023 9:32 AM Engineering and Project Management Matthew McLean Additional Reviewer Completed 06/12/2023 1:41 PM Transportation Management Operations Support Evelyn Trimino Additional Reviewer Completed 06/13/2023 3:52 PM Growth Management Community Development Department Diane Lynch Growth Management DepartmentCompleted 06/16/2023 5:28 PM Engineering & Natural Resources Jack McKenna Additional Reviewer Completed 06/21/2023 2:53 PM Growth Management Community Development Department Jaime Cook Division Director Completed 06/27/2023 10:03 AM Growth Management Community Development Department James C French Growth Management Completed 07/05/2023 4:43 PM County Attorney's Office Derek D. Perry Level 2 Attorney Review Completed 07/13/2023 2:30 PM Office of Management and Budget Debra Windsor Level 3 OMB Gatekeeper Review Completed 07/13/2023 3:38 PM Office of Management and Budget Laura Zautcke Additional Reviewer Completed 07/13/2023 7:03 PM County Attorney's Office Jeffrey A. Klatzkow Level 3 County Attorney's Office Review Completed 07/14/2023 2:11 PM Packet Pg. 81 16.A.2 07/25/2023 County Manager's Office Board of County Commissioners Geoffrey Willig Level 4 County Manager Review Geoffrey Willig Meeting Pending Completed 07/17/2023 8:37 AM 07/25/2023 9:00 AM Packet Pg. 82 16.A.2.a ESPLANADE AT HACIENDA LAKES PHASE 3 LOCATION MAP a Packet Pg. 83 16.A.2.b Exhibit A Utilities Performance Security (UPS) and Final Obligation Bond Amount Receipt Number 10% UPS Bond With Plat Final Obligation Bond $4,000 2019590966 Total Amount $4,000 The 10% UPS Bond, if applicable, is based on the total amount of the water and/or sewer utilities being installed for the whole project which includes material and labor. The contributory assets reflect the cost of materials, not labor and are based on the assets of which the county will be owning and maintaining. Final Obligation Bond, if applicable, in accordance with Utility Ordinance 2004-31 Attachments: 1. Verification of Final Cost 2. Receipt of Payment '-I a Packet Pg. 84 16.A.2.b VERIFICATION OF FINAL COST PROJECT NAME: Esplanade at Hacienda Lakes Phase 3 LOCATION: Part of Section 23, Township 50 South, Range 26 East Collier County, Florida NAME & ADDRESS OF OWNER: Taylor Morrison of Florida, Inc. 551 North Cattlemen Road - Suite 200 Sarasota, Florida 34232 TYPE OF UTILITY SYSTEM: POTABLE WATER (MATERIAL AND SERVICES) v vakcl rvtail I k��Uu, LIFN- IQ) n 'I VI f LF $18.70 $32,107.90 PVC Water Main (C900, DR-18) 8" 363 LF $24.06 $8,733.78 PVC Water Main (C900, DR-1 8) 101, 1223 LF $31.24 $38,206.52 PVC Water Main (C900, DRA4) 6" 122 LF $19.93 $2,431.46 PVC Water Main (C900, DR-14) 8" 42 LF $26.17 $1,099.14 PVC Water Main (C900. DR-14) 10.. 43 LF $34.47 $1,482.21 Single Water Service, Complete 1" 22 EA $699.80 $15,395.60 Double Water Service, Complete 1.51, 29 EA $918.52 $26,637.08 6" Gate Valve 6 EA $1,094.48 $6.566.88 8" Gate Valve 6 EA $1,468.84 $8,813,04 10" Gate Value 3 EA $2,046.72 $6,140,16 Temporary Blow Off w/ Bacterial Sample Point 4 EA $2,207.34 $8,829.36 Fire Hydrant, Complete 8 EA $4,312.72 $34,501.76 Connect to Existing Water Main 3 EA $2,221.00 $6,663.00 Permanent Bacterial Sample Point 1 EA $1,920.78 $1,920.78 Temporary Bacterial Sample Point 1 EA $89.65 $89.65 TOTAL COST $199,618.32 I do hereby certify that the quantities of material and services described above are a true and v accurate representation of the as -installed cost of the system. Q M C 4Jay FYING: IL LO 00 LO reschnick, Vice President N Q OF: Haleakala Construction, Inc.' 5758 Taylor Road Naples, Florida 34109 X W STATE OF Florida COUNTY OF Collier a� E t ca The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who is Q personally known to me X_ OR who produced identification Type of Identification Produced ��941l3�tilifli77�{ �.,;e-�.l�iA K Sff1o1A��ii ,41,9 R; . Rom: Seal: — �Q�� aofi�' Notary Public •_. #GG 1667717 + i��p°.OFI�d dW yc x�'`E'°'tda Shc TAF Packet Pg. 85 16.A.2.b VERIFICATION OF FINAL COST PROJECT NAME, Esplanade at Hacienda Lakes Phase 3 LOCATION: East of C.R. 951 and South of Rattlesnake Hammock Road NAME & ADDRESS OF OWNER: Taylor Morrison of Florida, Inc. 551 North Cattlemen Road - Suite 200 Sarasota. Florida 34232 TYPE OF UTILITY SYSTEM, SANITARY SEWER (MATERIAL AND SERVICES) ITEM SIZE QUAN. UNIT COST TOTAL Connect to Existing Sanitary Sewer 1 EA $5,568.90 $5,568.90 8" PVC Sanitary Sewer SDR-26 (0-6) 8" 139 LF $41.07 $5.708.73 8" PVC Sanitary Sewer SDR-26 (6-8') 8" 861 LF $50.07 $43,110.27 8" PVC Sanitary Sewer SDR-26 (8-10') 8" 409 LF $59.07 $24,159.63 8" PVC Sanitary Sewer SDR-26 (10-12') 8" 376 LF $73.07 $27,474.32 8" PVC Sanitary Sewer SDR-26 (12-14') 8" 503 LF $87.07 $43,796.21 B" PVC Sanitary Sewer SDR-26 (14-16') 8" 192 LF $111.07 $21,325.44 8" PVC Sanitary Sewer SDR-26 (16-18') 6" 288 LF $135,07 $38,900,16 Manhole 4' Diameter with Coating (0-6') 4' 2 EA $5,231.42 $10,462,84 Manhole 4' Diameter with Coating (6-8') 4' 2 EA $6,344.62 $12,689.24 Manhole 4' Diameter with Coating (8-1 T) 4' 1 EA $7,404.82 S7,404.82 Manhole 4' Diameter with Coating (10-12') 4' 3 EA $8,884.96 $26,654.88 Manhcie 4' Diameter with Coating (12-14') 4' 1 EA $10,038,82 $10,038.82 Manhole 4' Diameter with Coating (14-16') 4' 2 EA $11,317,76 $22,635.52 6" Single PVC Sewer Service w/ Cleanout 6" 1 EA $755.10 $755.10 6" Doubfe PVC Sewer Service wl Cleanout 6" 35 EA S781-60 $28,137.60 Television Inspection 2,768 LF $2.20 $6,089.50 TOTAL COST $334,912.08 I do hereby certify that the quantities of material and services described above are a true and accurate representation of the as -installed cost of the system. qJay TIFYING: on O schnick, Vice Presid nt OF: Haleakala Construction, Inc. 5758 Taylor Road Naples, Florida 34109 STATE OF COUNTY OF Florida Collier The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who is personally known to me _X_ OR who produced identification Type of Identification Produced Ckl_."di n x k _2h pn Notary Public / aawva��Si1NA K S17i0�`fa✓�, S10iV'. Seal: 0���8ER #FCG 166717 r,9 • �02N�90'7de d th�� ors Pia"."rl01ery 5c;.= CF`e�;' M LL Q Packet Pg. 86 Receipt Number: Transaction Number: Date Paid: Amount Due: Payment Details: Amount Paid: Change / Overage: Contact: FEE DETAILS: Fee Description Utility Performance Refundable Bond Cashier Name: Batch Number: Entered By: Collier County Growth Management Division 2800 Horseshoe Drive N. Naples, FL 34104 239-252-2400 RECEIPT OF PAYMENT 2019590966 2019-014240 02/14/2019 $4,000.00 Payment Method Amount Paid Check Number Check $4,000.00 14000-00068420 $4,000.00 $0.00 TAYLOR MORRISON OF FLORIDA INC 551 N. CATTLEMEN RD. SUITE 200 SARASOTA, FL 34232- Reference Number PL20190000415 Karinalloble 8037 LuciaMartin Original Amount GL Account Fee Paid $4,000.00 $4,000.00 670-000000-220113 '-f a Packet Pg. 87 16.A.2.c CERTIFICATION OF CONTRIBUTORY ASSETS - COUNTY PROJECT NAME: LOCATION: NAME & ADDRESS OF OWNER: TYPE OF UTILITY SYSTEM: Esplanade at Hacienda Lakes Phase 3 East of C.R. 951 and South of Rattlesnake Hammock Road Taylor Morrison of Florida, Inc. 551 North Cattlemen Road - Suite 200 Sarasota, Florida 34232 POTABLE WATER (MATERIALS ONLY) ITEM SIZE QUAN. UNIT PRICE TOTAL PVC Water Main (C900, DR-1 8) 6" 1717 LF $4.70 $8,069.90 PVC Water Main (C900, DR-18) 8" 363 LF $8.06 $2,925.78 PVC Water Main (C900, DR-18) 10" 1223 LF $12.24 $14,969.52 PVC Water Main (C900, DR-14) 6" 122 LF $5.93 $723.46 PVC Water Main (C900, DR-14) 8" 42 LF $10.17 $427A4 PVC Water Main (C900, DR-14) 10" 43 LF $15.47 $665.21 Single Water Service, Complete 1" 22 EA $349.80 $7,695.60 Double Water Service, Complete 1.5" 29 EA $468.52 $13,587.08 6" Gate Valve 6 EA $644.48 $3,866.88 8" Gate Valve 6 EA $968.84 $5,813.04 10" Gate Value 3 EA $1,496.72 S4,490A6 Temporary Blow Off w/ Bacterial Sample Point 4 EA $1,207.34 S4,829.36 Fire Hydrant, Complete 8 EA $2,662.72 $21,301.76 Connect to Existing Water Main 3 EA $371.00 $1,113.00 Permanent Bacterial Sample Point 1 EA $1;020.78 $1,020.78 Temporary Bacterial Sample Point 1 EA $62.10 $62.10 TOTAL COST $91,560.77 I do hereby codify that the quantities of material described above are a true and accurate representation o€the system being contributed to Collier County Utilities. RTIFYING: C)" Ja on O eschnick, Vice President OF: Haleakala Construction, Inc. 6758 Taylor Road Naples, Florida 34109 STATE OF Florida COUNTY OF Collier The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who is personally known to me _X_ OR who produced identification Type of Identification Produced a IbArwga— Nofary Public ��da1r�4;11%49r61��7� Seal: y OGG 186717 O OSA��d1���1 ri 91ts14`q,�� Packet Pg. 88 16.A.2.c CERTIFICATION OF CONTRIBUTORY ASSETS - COUNTY PROJECT NAME LOCATION: NAME & ADDRESS OF OWNER: TYPE OF UTILITY SYSTEM. Esplanade at Hacienda Lakes Phase 3 East of C.R. 951 and South of Rattlesnake Hammock Road Taylor Morrison of Florida, Inc. 551 North Cattlemen Road • Suite 200 Sarasota. Florida 34232 SANITARY SEWER (MATERIALS ONLY) ITEM SIZE QUAN. UNIT COST TOTAL Connect to Existing Sanitary Sewer 1 EA $250.00 $250,00 8" PVC Sanitary Sewer SDR-26 (0-6') 8" 139 LF $5.07 $704,73 8" PVC Sanitary Sewer SDR-28 (64) 8" 861 LF $5-07 $4,365.27 8" PVC Sanitary Sewer SDR-26 (8-10') 8" 409 LF $5.07 $2,073.63 8" PVC Sanitary Sewer SDR-26 (10-12') 8" 376 LF $5.07 $1,906-32 8" PVC Sanitary Sewer SDR-26 (12-14') 8" 503 LF $5.07 $2,550-21 8" PVC Sanitary Sewer SDR-26 (14-16') 8" 192 LF $5-07 $973.44 8" PVC Sanitary Sewer SDR-26 (16-18') 8" 288 LF $5.07 $1,460 16 Manhole 4' Diameter with Coating (0-6) 4' 2 EA $3,081,42 $6,162.84 Manhole 4' Diameter with Coating (6-5) 4' 2 EA $3,884.62 $7,769.24 Manhole 4' Diameter with Coating (8-10') 4' 1 EA $4,554.82 $4,554-82 Manhole 4' Diameter with Coating (10-12') 4' 3 EA $5,634-96 $16,904.88 Manhole 4' Diameter with Coating (12-14') 4' 1 FA $6,038.82 $6.036.82 Manhole 4' Diameter with Coating (14-16') 4' 2 EA $6,567.76 $13,135.52 6" Single PVC Sewer Service w/ Cleanout 6" 1 EA $355.10 S355.10 6" Double PVC Sewer Service w! Cleanout 5" 36 EA $381-60 $13,737.60 Television Inspection 2,768 LF $0.00 TOTAL. COST $82,942.58 I do hereby certify that the quantities of material described above are a true and accurate representation of the system being contributed to Collier County Utilities._ OF: I Haleakala Construction, Inc. 5758 Taylor Road Naples, Florida 34109 STATE OF Florida COUNTY OF Collier The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who is personally known to me X OR who produced identification Type of Identification Produced Nota Public ` Packet Pg. 89 INSTR 5725224 OR 5640 PG 1334 RECORDED 6/11/2019 11:57 AM PAGES 7 CLERK OF THE CIRCUIT COURT AND COMPTROLLER, COLLIER COUNTY FLORIDA Doc@.70 $0.70 REC $61.00 CONS $10.00 16.A.2. d This Instrument Prepared by: Mark F. Grant, Esq. GREENSPOON MARDER LLP 200 E. Broward Blvd, Suite 1800 Fort Lauderdale, FL 33301 THIS IND ENTU, made this 1'l day of March, 2019, between TAYLOR MORRISON OF FL,6RIDA, INC., a Florida corporation (hereinafter referred to as "Grantor"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER HE GOVERNING BODY OF COLLIER COUNTY COUNTY, FLORIDA,�"AS AND AS THE EX-OFFIC10 GOVERNING BOARD OF THE COLLIER COUNTY WATER -SEWER DISTRICT,.# "sAccessors and assigns, (hereinafter referred to as "Grantee").` >v 1Ai That said Grantor, for and in co id and other good and valuable consideratit Grantee, the receipt whereof is hereby ackn to the said Grantee, and Grantee's heirs, s water utility facilities and/or system(s) or under the following described land, for opei maintenance of said facilities, system(s) or being in Collier County, Florida, to wit: [.Y0862A of the sum of Ten Dollars ($10.00) yid Grantor in hand paid by said ed, has granted, bargained and sold rr and assigns forever, all potable r( thereof lying in, on, over and 6location, installation, repair and/or ,s`, 4eie©f, all situate and lying and (See Exhibit "A" attached hereto and incorporated by reference herein.) (Exhibit "B" attached hereto is a sketch or other graphic representation tat d `picts the physical location of the utility systems being conveyd and said Grantor does hereby fully warrant the title to said dtjtrt facilities and/or system(s) or portion(s) thereof, be they realty, personalty, or mixed,,a d'rrantor will defend such title against all claims of all persons whomsoever. For the prposes of this conveyance, the utility facilities, system(s) and/or portion(s) there9f_conveyed herein shall not be deemed to convey any of the lands described in either exhibit. Grantor and Grantee are used for singular or plural, as context allows. A sketch or other graphic representation showing the location of the utility facilities, etc., being conveyed is attached as Exhibit B. TO HAVE AND TO HOLD the same unto the Grantee and its assigns, together with the right to enter upon said land, excavate, relocate and/or take or introduce materials for the purpose of constructing, relocating, operating, repairing and/or otherwise maintaining utility systems thereon. Grantor and Grantee are used for singular or plural, as the context requires. 38851234:1 Packet Pg. 90 OR 5640 PG 1335 16.A.2.d IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. TAYLOR MORRISON OF FLORIDA, INC., a Florida Corporation Signature" Print Name By: ANDREW MILLER, Authorized Agent -Land Development [CORPORATE SEAL] Print Name STATE OF FLORIDA ) ) SS: COUNTY OF Ue ) I HEREBY CERTIFY that on this day;6er€ the State aforesaid and in the County afore, d foregoing instrument was acknowledged before 4 Authorized Agent -Land Development of Taylor M( corporation, freely and voluntarily under authority corporation and that the seal affixed thereto is corporation, who is personally known to me. an officer duly authorized in take acknowledgments, the ANDREW MILLER, as n bf Florida, Inc., a Florida sted in him/her by said true _comorate seal of said WITNESS my hand and official seal in the County andf1 t aforesaid this e day of March, 2019. Notary k2kblic Typed, printed or stamped name of Notary My Commission Expires: CA-(1 W 12,C7-2 JESSICA K JINN =o state of Florida -Notary Public * *_ Commission # W 170818 M Commission Expires y April 18, 2022 38851234:1 Packet Pg. 91 OR 5640 PG 1336 16.A.2. d EXHIBIT "A" LEGAL DESCRIPTION TRACT "R", ESPLANADE AT HACIENDA LAKES PHASE 3, according to the Plat thereof as recorded in Plat Book 64, Pages 20 through 23, of the Public Records of Collier County, Vlurida. 38851234:1 Packet Pg. 92 OR 5640 PG 1337 EXHIBIT "B" SKETCH 38851234:1 Packet Pg. 93 64C epuG13eH }e opeuelds3 - selim;n;o eoue;d000V jeui.: B8L9Z) ales jo me pue peed AjuejjeM :;u9uay3e4jV N � Q � a1 � d N Y 1 C) • fC d d mer EM � ,92 ,sJ V�ya� 8� 1•'�S ir� 195 •p.� W o�yj 4_"_�..•�,�mag� 4=� r- � 1 F Ij(���� •x, � --- W �� ~ V C l� HC+'09b9'e ,3& uS Q �—_ _ p6 / l 5gyp{ 75 127 �•^i� ay a" \ tc rMcr Y• z t 11 leiz zi =:Iris rlr,�Inn �nI � I i Best Available Image OR 5640 PG 1339 16.A.2. d CERTIFICATION OF CONTRIBUTORY ASSETS - COUNTY PROJECT NAME: LOCATION: NAME & ADDRESS OF OWNER , TYPE OF UTILITY SYSTEM: , Esplanade at Hacienda Lakes Phase 3 East of C.R. 961 and South of Rattlesnake Hammock Road Taylor Morrison of Florida, Inc. 651 North Cattlemen Road - Suite 200 Sarasota. Florida 34232 SANITARY SEWER (MATERIALS ONLY) Connect to Existing Sanitary Sewer "c; 1 EA $250.00 $250.00 8" PVC Sanitary Sewer SDR-26 (0.6') 8" 139 LF $5.07 $704.73 8" PVC Sanitary Sewer SDR-26 (6-8') 8 861 LF $5.07 $4.365.27 8" PVC Sanitary Sewer SDR-26 (8-10') ri„� C" 4D9 LF $5.07 $2,073.63 8" PVC Sanitary Sewer SDR-26 (10-121) 376 LF $5.07 $1,906.32 8" PVC Sanitary Sewer SDR-26 (12-14') 8" 503 ' LF $5.07 $2,550.21 8" PVC Sanitary Sewer SDR-26 (14-16') ,P 8 s 192 LF $5.07 $973.44 8" PVC Sanitary Sewer SDR-26 (16-18') 288 LF $5.07 $1,460.16 Manhole 4' Diameter with Coating (0-6') 4 2 EA $3,081.42 $6,162.84 Manhole 4' Diameter with Coating (6-8') 2 EA $3,864.62 $7,769.24 Manhole 4' Diameter with Coating (8-10') 4" 1 EA $4,554.82 $4,554.82 Manhole 4' Diameterwlth Coating (10-12') 4' %-'� ?.,'^.; 3 EA $5.634.96 $16,904.88 Manhole 4' Diameter with Coating (12-14') Manhole 4' Diameter Coating 4' EA $6,038.82 $6,038.82 with (14-16')% 4' •! EA $6,567.76 $13,135.52 6" Single PVC Sewer Service w/ Cleanout B" 1 3 E4 $355.10 S355.10 6" Double PVC Sewer Service w/Cleanout EA $361.60 $13,737.60 Television Inspection LF LF $0.00 $82,942.58 I do hereby certify that the quantities of material described above are a true and accurite repre e' Mafion of the system being contributed to Collier County Utilities. f CERTI YING: Jayso Ores hnick, Vice President " OF: Haleakala Construction, Inc. 5758 Taylor Road .. Naples. Florida 34109 ti STATE OF Florida' COUNTY OF Collier The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who Is,�- personally known to me X OR who produced identification Type of Identification Produced �S(1NA K Sy/A'�ir�r rn�Qj— Seal: V�.•�t�1 SIO F r Nota Public -� #GG 166717 �09� ys�N ded it Packet Pg. 95 *** OR 5640 PG 1340 *** 16.A.2.d PROJECT NAME: LOCATION: CERTIFICATION OF CONTRIBUTORY ASSETS - COUNTY Esplanade at Hacienda Lakes Phase 3 East of C.R. 951 and South of Rattlesnake Hammock Road NAME & ADDRESS OF 01A1R TYPE OF UTILITY SYSTEM: Taylor Morrison of Florida, Inc. 651 North Cattlemen Road - Suite 200 Sarasota. Florida 34232 POTABLE WATER (MATERIALS ONLY) ITEM SIZE QUAN. UNIT PRICE TOTAL PVC Water Main (C900, DR-18) s "" - 6" 1717 LF $4.70 $8,069.90 PVC Water Main (C900, DR-18) +;' 8" 363 LF $8.06 $2,925.7e PVC Water Main (C900, DR-18) tQ, 1223 LF $12.24 $14,969.52 PVC Water Main (C900, DR-14) 122 LF $5.93 $723.46 PVC Water Main (C900, DR-14) j 42 LF $10.17 $427.14 PVC Water Main (C900, DR-14) 1 '" " 43 LF $15.47 $665.21 Single Water Service, Complete ,t, `k 22 ,. EA $349.80 $7,695.60 Double Water Service, CompleteisSW=„``w";;,., 29 EA $468.52 $13,587.08 6" Gate Valve 6 "` 4 EA $644.48 $3,866.88 8" Gate Valve „ 6 EA $968.84 $5,813.04 10"Gate Value aef 3 EA $1,496.72 $4,490.16 Temporary Blow Off w/ Bacterial Sample Point "'l '4 4 EA $1,207.34 $4,829.36 Fire Hydrant, Complete 8 EA $2,662.72 $21,301.76 Connect to Existing Water Main �J EA $371.00 $1,113.00 Permanent Bacterial Sample Point FA $1,020.78 $1,020.78 Temporary Bacterial Sample Point 1 ,. `` , EA $62.10 $62.10 I do hereby certify that the quantities of material described above are a true and contributed to Collier County Utilities. qoRTIFYING-.. n O ie schnick, Vice President OF: Haleakala Construction, Inc. 5758 Taylor Road Naples, Florida 34109 STATE OF Florida COUNTY OF Collier $91,560.77 of the system being The foregoing instrument was signed and acknowledged before me this 9th day of April, 2019 by Jayson Oreschnick who is personally known to me _X_ OR who produced identification Type of Identification Produced Mnk�& K r Nofary Public ,���011111'lai ®sd� 1N K Sh/p si�i Seal: ti,�C���OM1ssI0NF•: �yy �' �c v�BERIp �''vv '<o4r• Q y S Z : ##GG 166717 Packet Pg. 96 ¢,,,ra „r,,,n„l-H1. , d,- ,,,,,,w,,,,, �,��.�-:`�:"zi-d,w Kea,,, 4— LJ a W ,qa��sp„s-- $ e"''3 .�<ggQ� _ og$Hg.W-'a+ry�, $° z�<� •. � � ¢ � t� _ a� ,� W Wm WI �42 W i I _ E2 , e^o22s x 12 x F�ii s a�Wg ow es�p hay o�''�=� W$3$�G '2 �z 22 W ¢ z $ WW4m } 24K' a<p €zo Z.Zm o ig I 2 ��o - cn "m � i °44a • �� S< W° i� � � I (Wz � $ o F$���a. �W c� "�� � � Q i e 2 r m2 e P� p I 99op 18 � `O�GKETT h G= # 4i �sQ? is W ` Q�40iJQ�rczoomz$ WWeQe�ai� $Y pOhO��O 0 v'woaaF��F Q 00v �l �muoi3� Z oiUho0 owa� 41 M7X���@�'am �,i �h Q�Z p " aozsoa W Q i^� lip m$mpNs��� Wo V W2 p$ U �� J o��og� W aak�W x $Q i z U QOWZO ��zzwo- 4 �4 °Zm., OUZ aLL�war-z �S+ i 7X �a �u�Oaa`aoo°"°c OmZy zoi?o�� " m$m mex a kz IVVTVV� 0 Q ZO \\ p c�ii ha Q � . $i��Ph 1 `eiWmW$ $ � m � � 4 WA xe ^'Nt�AH .1i W e i $ } �Wi$m'Y3gma - z z W `3�7X-A<m� a d 3 WeW e& $ WQC < $ $I i �W z -i � x a ��Q"W� � .x 1 ;� .^ �' $i L^e3 '� �m m 4� �ekcT� �" a� o ii $ � $$$ Wig •�' u h �c ° ��k � W�.$�$ ��xo� � ` u j w$$m°Q�� � m s� dW Q M -9 eI WI"a i mC _ e ra A obi w �xr ,°�, W� , F laqu-m 0 � $° J 2�g W �� W Ne W �Q Np i� 3 2 mii¢F W �yt 4 2^ u' 2 3 �f 4 '8^ elm^4 =$aia�i� >�Q 2 J22 2cp O <ii Z1 R Wm �4 4$OS"2 N 4 4ecimWciC S" $ 2z�Ra ;zW � $$� zYi� � N ' $ i$�z�'� pa a z<�e em° ° �` <22�'���u &� °m o " n 8 �Cy;' ss an 9 a .... . Ya�Q98 ki"ems U W�W�mb": J�h���y^8��$zip3��BxWj��W�iSm�W 5zex¢tx €W�oCBo�`x� $bow a'��N.B�g e6�.`xmOsN,N 4 hNnW I mii ���4z" r� JWWeQi- Cal a�g���'� $ im e�'�`$$a�4¢§ ;Ke�B� ¢ 0Wc��$ �a `,000pa o�`$ �-N� W V,W�?E2e�z,�NapaNWx���o��9 g6g,"AWWg -gaogOQ vs �pzW�agWW'Nax� ," �S"�g m�mUaBeoW�?ri g�$,_ = �M ��`o m W NWU r`�> i��¢^" (��W2F � ¢��¢--L�i�" 4Ni h m SW �•,¢ E bs,iQNum ga "2yx��m¢iQ�W¢W�i= 88�i`�`"m�¢�i`Wm�hb�zgii�aag�� ig��mNa ��g a d r�hl �`x� x m= W��� m.Y W0gN Q�` Wg « �¢�¢mr�$ � Z�aW�w�gp�Mw�(`aNe ��`'2e �U2,¢W�N P•w2 HE AINDER O IRACr F1" ESTLANADE AT HACIENDA LAKES PHASE ONE (MAT 9IXM' S5. PAGE IJ TRACT 'P(/E3'— W b� �m 2 waif nwnF DUCT W W 333 go U. �7n a C: rflmNw W� d ,g41 " g ;'�B�ggG�g os Q W LINE CY E N.E. 1% LY SECA(AV 2J 2� Wm g� �x 9f 9� s Wf�f�fryCtututb u aM mM., VpA O m 2 0R�420 vti-=JWOiU � 0� ���`Q� 4 1 a 2 � e FT-1 pa a 3a w'�+0� HdmZ LIj '�� W hy1 z2Zo _ O Ricn C 2 J p N M� m vtt E-F J2n 8 2 M I I 1ta 145 R 198 I MATCHLINE 241 SEE SHEET 4 V 1 I N OOSB 02"-W 115 I 144 199 199 240 Nw-02"W I f200 NW5802"W ,39.s0" ' 8 Q 116 w i y 143 R I 239 LN ti +{ ,142117 T"W NN —W' WW 201 7-$,W• 118 41 .0,2 a' FN R 119 140 W^Tc�i�IIIi' W Ohm4j 120 139 W 203 ° W z Q I " I323 - /l�_ h N OI1190g" E i � W. L/NE OF 7NE N.E. 1/4 -- - � 138 �.:. " �-�' o rXl 1,!! 02"w-�- "I ` 235 NW�"�"W ` `v Q � W J Q ° O ° OF SECNON 23 1 I 137 NW5B _ _ _ _ i IJQ00" w ✓` y $ I 234 y W O 122 •.`�`/ w 205 h m°{�Ip n IQ� OQiy NW53'02"W �y' NW5802"W � h N 123 I I r"�,'...\y3 Z m 206 233 u) O j j 4 250" 250• i I N WSB'02" w 2 I N W-'12" W lIea8 W O W -• 'E124 135 207 iI m 2.3502U L_ _ ]____ - 3om 301' " Y u �y W v O `} Qy, i 1 125 134 _ _JaW"____ _ _ _�_____ __rJ9so'_____ 231 mm $ m �Q� V W`m- 1 I NW3BOZ"w 4 I m! NGGSBO?"W $ �` v U i 126 133 ,JaW' 209 139.50" 230 j W 132 y y� x WSBbz" w x Wse'9z' w y �,s I\ 127 I zxo' zso' W 30.00" r 's III 131 210 I $I yR-.i 229 Q h ° 128 Ow NN- Oe¢ Z 912 u130 f 21W1 .w ^3 Jmy )ffiWI3!39" oso" w N 22,8 o'o3sB"a.90W ¢ I ' 4 - 9 ODSB'02' E - _ J \ 4 37.i-d11' J]O.W" N oose'oz" w , oo' � °�' �'4 J o )O"P.U.E N "W foa]6' 10"P.UE. O W 14_—_EJ�_ W 6J2W" TSW' '� N wWw—w_____LUCELLO_JOERRA TSW' 6o_ ?W0- 3].60'TRA 60 _,RJI.b _P.UJl.60 39.60' -d: 39.60" 3>60' 3].60 J],60' V., J]60 I[JO" ____T &�T_ W „ Ope Ng� Nm� Cl$2 No? hN Cly� N�� Ny� N b� N aNN �nN m�N �hN q'�iN $hN gblV l b,m� ^A m 2 2 2 h2 2 2 2 2 2 2 2 2 i 20 2 P m 2 2 � m i 2 L9-,Z-LF- -,Z9LF- --- ,C6L[9 __-------- /� _------ ____ W lOYNl (an 39res Nid7) ,LO, _______ ______________________ry ,060L9 3.S[,IQION m _ f/ SON.7 OjUY7dNN m�ti¢Q WUUW4 2Z�¢W Y R NJ W a � 0 J O x Lo O w m V) WWW333W3W WW W3W3 W�8SRS8Sa W Nx2xN ZN�2z2zxz^xzz mBSooS s�S 2 Zw� °dn 2� 8 " W8 N NaA h �^ o REMAINDER. OF TRACT Fl" (N OEVLZOPMENT. A.E, O.E. LE121 ESPLANADE AT HACIENDA LAKES PHASE DIVE (PLAT BOON S . ACE 1) TRACT WE3'X/OD• (OPEN SPACE PPE) /O(M'-� .......�.•�.k.-JO.00' WALE CIRCLE TRACT ' r �a W33 333 33 W W WWWW W333W W33W W WWW WWWWWWWW WWW33 :-:.�N N a :. qi. n:...oyN ''fiN 'N eAo a A,`v A Noe'oN a -Si-9i �N NN 222 22 22 222222222222222 222222222 2222 222 2 eRh;ecgm�-N--- �42' oh a o^H h'mm"; � W Fu m� hhh'pOti^�RKnnnh^ �M�, �N� e 7.'°$'.^� hq$. r� ^hg�Ra3h=aht, jo S.H "q-RP� eel^ ,BSr :n r3 �o8S�88G8S�G��S�os���N <NN^N Rood oW RR N8^ W ' ' ESPLANADE AT HACIENDA LAKES PH. W o � i (PLAT BOOK 62 PAGE 98) WALE CIRCLE TRACT R - V/ — — — -- -- - ------------------------ — -------------- -------- r— U _^ c, , 107 I I ctZ h � 108 109 h��QQWO I LV 110 /� I[�1 1 ��5Q-W o:c! p,;K rL W Q LW p Q h p Q p h h--- �O�J?m`�NZ a Q:m -----`----- �VOQUQZLu n2 113 p Q J Qj� J Q h�lUO W �p I 1� 'KL,7j hJW �BpZzo _