Loading...
HEX Final Decision 2022-46HEX NO. 2022-46 HEARING EXAMINER DECISION DATE OF HEARING. October 13, 2022 PETITION. Petition No. BD-PL20220002460 — 493 Willet Ave - Nelson Marine Construction - Request for a 648 square foot boathouse allowed by Section 5.03.06.F of the Land Development Code, to accommodate an existing approved boat dock permit with a total protrusion of 20 feet, consisting of two boat slips, pursuant to Section 5.03.06 of the Collier County Land Development Code, for the benefit of Lot 19, Conner's Vanderbilt Beach Estates Unit 2 Block N, also described as 493 Willet Avenue, in Section 29, Township 48 South, Range 25 East, Collier County, Florida. GENERAL PURPOSE FOR THE PETITION. The purpose of the project is the construction of a 648 SF boathouse with a brown asphalt shingle roof. The facility will protrude a total of 20 feet into a waterway 100 feet wide and consist of two boating vessels of 30 feet and 24 feet long. STAFF RECOMMENDATION. Approval with conditions. FINDINGS. 1. The Hearing Examiner has jurisdiction over this Petitioner pursuant to Sec. 2-87(4) of the Collier County of Ordinances, Sec. 8.10.00 of the Land Development Code, and Chapter 9 of the County Administrative Code. 2. The public hearing for this Petition was properly noticed and conducted in accordance with all County and state requirements. 3. The public hearing was conducted electronically and in -person in accordance with Emergency/Executive Order 2020-04. 4. The Petitioner and/or Petitioner's representative executed the Hybrid Virtual Quasi -Judicial Public Hearing Waiver related to conducting the public hearing electronically and in -person. 5. The County Staff presented the Petition followed by the Petitioner and/or Petitioner's representative, public comment and then rebuttal by the Petitioner and/or Petitioner's representative. There were no objections made at the public hearing. Page 1 of 7 6. The County's Land Development Code (LDC) Sections 5.03.06.E and 5.03.06.F. lists the criteria for boathouses. The Hearing Examiner may approve, approve with conditions, or deny a request for a boathouse if it is determined that the criteria, which are applicable in LDC Sections 5.30.06.E. and 5.03.06T have been met.' Section 5.03.06.E Criteria: 1. For lots on a canal or waterway that is 100 feet or greater in width, no boathouse or dock facility/boat combination shall protrude more than 20 feet into the waterway (i.e., the total protrusion of the dock facility plus the total protrusion of the moored vessel). The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. In relation to the 100 feet width of the waterway, the proposed boathouse and moored vessel combination protrude a total of 20 feet. 2. For lots on a canal or waterway that is less than 100 feet in width, dock facilities may occupy no more than 25 percent of the width of the waterway or protrude greater than 20 feet into the waterway, whichever is less. The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. Criterion 1 above was met since the waterway is a total of 100 feet in width. 3. On manmade canals 60 feet or less in width, which are not reinforced by a vertical seawall or bulkhead, dock facilities may protrude up to 33 percent of the width of the waterway, provided that the procedures outlined in section 5.03.06(C) are followed. The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. Criterion I above was met since the waterway is a total of 100 feet in width. 4. For lots on unbridged barrier islands located within state aquatic preserves, protrusion limits, setbacks, and deck area shall be determined by the applicable Florida Department of Environmental Protection (DEP) regulations in effect at the time of permit application, and the protrusion limits above shall not apply. All required DEP permits for a dock facility must be obtained prior to the issuance of a Collier County building permit for the facility. The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. Subject lot is not located on unbridged barrier islands within state aquatic preserves and is zoned RSF3. 5. All dock facilities on lots with a water frontage of 60 feet or greater shall have a side setback requirement of 15 feet, except as provided in subsections 5.03.06(E) or 5.03.06(F) of this LDC or as exempted below. 'The Hearing Examiner's findings are italicized. Page 2 of 7 The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. The proposed facility is located on a lot that contains 104.5 feet of total property water frontage. The setbacks to the boathouse facility are 15 feet at minimum from each property line. 6. All dock facilities, except boathouses, on lots with less than 60 feet of water frontage shall have a side setback requirement of 7.5 feet. The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. The dock facility proposed is a boathouse. 7. All dock facilities, except boathouses, on lots at the end or side end of a canal or waterway, shall have a side setback requirement of 7.5 feet as measured from the side lot line or riparian line, whichever is appropriate. The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. The dock facility proposed is a boathouse. 8. Riparian lines for lots at the end or side end of a waterway with a regular shoreline shall be established by a line extending from the corner of an end lot and side end lot into the waterway bisecting equidistantly the angle created by the 2 intersecting lots. The record evidence and testimony from the public hearing reflects that the criterion HAS BEENMET. See Exhibit "A " with the location of where the riparian lines are marked. 9. Riparian lines for all other lots shall be established by generally accepted methods, taking into consideration the configuration of the shoreline, and allowing for the equitable apportionment of riparian rights. Such methods include, but are not limited to, lines drawn perpendicular to the shoreline for regular (linear) shorelines, or lines drawn perpendicular to the centerline (thread) of the waterway, perpendicular to the line of deep water (line of navigability, or edge of navigable channel), as appropriate, for irregular shorelines. The record evidence and testimony from the public hearing reflects that the criterion HAS BEENMET. See Exhibit "A" with the location of where the riparian lines are marked. 10. All dock facilities, regardless of length and/or protrusion, shall have reflectors and house numbers, no less than 4 inches in height, installed at the outermost end on both sides. For multi -family developments, the house number requirement is waived. The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. Applicant will abide by and install house number reflectors on their boathouse facility per LDC requirements. Page 3 of 7 11. Multi -slip docking facilities with 10 or more slips will be reviewed for consistency with the Manatee Protection Plan ("MPP") adopted by the BCC and approved by the DEP. If the location of the proposed development is consistent with the MPP, then the developer shall submit a "Manatee Awareness and Protection Plan," which shall address, but not be limited to, the following categories: a. Education and public awareness. b. Posting and maintaining manatee awareness signs. c. Information on the type and destination of boat traffic will be generated from the facility. d. Monitoring and maintenance of water quality to comply with state standards. e. Marking of navigational channels, as may be required The record evidence and testimony from the public hearing reflects that the criterion IS NOT APPLICABLE. There are only two slips in total and, therefore, this is not considered a multi -slip docking facility. Section 5.03.06.17 Criteria: 1. Minimum side setback requirement: Fifteen feet. The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. The proposed boathouse meets the minimum 15 feet setback from each property line. 2. Maximum protrusion into waterway: Twenty-five percent of canal width or 20 feet, whichever is less. The roof alone may overhang no more than 3 feet into the waterway beyond the maximum protrusion and/or side setbacks. The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. The proposed boathouse consists of a maximum protrusion of 20 feet. The roof only overhangs the maximum protrusion by an estimate of 1 '-3 " (1.25 feet) which is less than the maximum roof overhang of 3 feet beyond the maximum protrusion. 3. Maximum height: Fifteen feet as measured from the top of the seawall or bank, whichever is more restrictive, to the peak or highest elevation of the roof. The record evidence and testimony from the public hearing reflects that the criterion HAS BEENMET. The proposed boathouse is a maximum of 15 feet from the top of the seawall to the peak of the roof. 4. Maximum number of boathouses or covered structures per site: One. The record evidence and testimony from the public hearing reflects that the criterion HAS BEENMET. The only boathouse to be developed on this subject property is this proposed boathouse. Page 4 of 7 5. All boathouses and covered structures shall be completely open on all 4 sides. The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. The proposed boathouse is open on all four sides. 6. Roofing material and roof color shall be the same as materials and colors used on the principal structure or may be of a palm frond "chickee" style. A single-family dwelling unit must be constructed on the subject lot prior to, or simultaneously with, the construction of any boathouse or covered dock structure. The record evidence and testimony from the public hearing reflects that the criterion HAS BEEN MET. The existing house was built in 1961. The existing single-family residence serves as the principal structure and consists of a roof that is the same color as the proposed boathouse which will be brown asphalt shingles. 7. The boathouse or covered structure must be so located as to minimize the impact on the view of the adjacent neighbors to the greatest extent practical. The record evidence and testimony from the public hearing reflects that the criterion HAS BEENMET. There is no adjacent neighbor on the east side. This lot is at the dead end of a canal, it wraps around the end of the canal, and the property fronts on Willet Ave. There is a seawall and the street which makes up the view for the neighbor on the west side. Regarding the neighbor to the north, there is no major impact since the canal is 98 feet wide, so the outside boathouse piling is 78 feet south of the opposite side of the canal seawall. Lastly, the boathouse is in the only available location on this lot which is 1 S feet from the property line to the outside of the boathouse piling. ANALYSIS. Based on a review of the record including the Petition, application, exhibits, the County's staff report, and hearing comments and testimony from the Petitioner and/or the Petitioner's representative(s), County staff and any given by the public, the Hearing Examiner finds that there is enough competent, substantial evidence as applied to the criteria set forth in Section 5.03.06.H of the Land Development Code to approve Petition. The Petition meets 5 of the 11 criteria in LDC Section 5.03.06.E, with 6 criteria being not applicable and 7 out of 7 of the criteria in Section 5.03.06.F. DECISION_ The Hearing Examiner hereby APPROVES Petition Number BD-PL20220002460, filed by Nelson Marine Construction representing Stephen Buchalter, with respect to the property described as Lot 19, Conner's Vanderbilt Beach Estates Unit 2 Block N, also described as 493 Willet Avenue, in Section 29, Township 48 South, Range 25 East, Collier County, Florida for the following: Page 5 of 7 • A 648 square foot boathouse allowed by Section 5.03.06.F of the Land Development Code, to accommodate an existing approved boat dock permit with a total protrusion of 20 feet, consisting of two boat slips, pursuant to Section 5.03.06 of the Collier County Land Development Code. Said changes are fully described in the Proposed Boathouse Plans attached as Exhibit "A" and are subject to the condition(s) set forth below. ATTACHMENTS. Exhibit A — Proposed Boathouse Plans LEGAL DESCRIPTION. Lot 19, Conner's Vanderbilt Beach Estates Unit 2 Block N, also described as 493 Willet Avenue, in Section 29, Township 48 South, Range 25 East, Collier County, Florida CONDITIONS. 1. All other applicable state or federal permits must be obtained before commencement of the development. 2. Corresponding permits from the Florida Department of Environmental Protection shall be provided to Collier County prior to the issuance of a building permit. 3. Reflectors and house numbers of no less than four inches in height shall be installed at the outermost end, on both sides of all docks or mooring pilings, whichever protrudes the furthest into the waterway, prior to the issuance of a Certificate of Completion. DISCLAIMER. Pursuant to Section 125.022(5) F.S., issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. APPEALS. This decision becomes effective on the date it is rendered. An appeal of this decision shall be done in accordance with applicable ordinances, codes and law. Page 6 of 7 RECORD OF PROCEEDINGS AND EXHIBITS: SEE CLERK OF COURT, MINUTES AND RECORDS DEPARTMENT. DECISIONS OF THE HEARING EXAMINER FOR VARIANCES, CONDITIONAL USES, AND BOAT DOCK EXTENSIONS SHALL BE NOTED ON THE ZONING MAP FOR INFORMATIONAL PURPOSES. Date Andrew Dickman, Esq., AICP Hearing Examiner Page 7 of 7 EXHIBIT "A" �W T ,Da.aNeWm.�m ..u�I w'.I�e.... wr�i e•;ir w ' n bN sECT%oN VIEw ,,,I u Tf• W Ns�f P e.ePatl b•rYn _ mlwrw. p �ro a SITE PUN Qi mP a u. m.umi sue• a L w°i n u. � mair w mn''..x,i` /7,� f Aoaue m mna�ivK �n mien m�0',mI f IRl) .+¢f m K vIIe Ion KII,4 o41P ow' a M FLOATING TUF 0B 6.MLW.. rw w u)•Y.,r.,..me i .Em2-7 • r.,r '+• � NDTE: fxIX I w•ac wm l.uss t�mLlKd P� n) i Pa c xRC LEND DET-Qi xPlcu.laP eP,YCE DETAIL —C SEAT RATES WT PEDtPPED '�'�•— Fdl— 'y_'•ZRS@ Hart w NEcww,w tw�vNDEi Loew !'—= OP Hunt FPaw iNll= �•�� • •Am n.n0.EA5OR WAiEP nFATEP9 II w�ND�„ '>Y Ls T IgtE T��i AntONDRODF LOeDf wnlD„ ExDEE01oW. OP SMM aRI.VrtYOn i,o5 JDe NOTES b KW CMPI1m tic,w,P O •dim, .0 w,t. ]•�olm,~.�n,W of/,V�• . mArtNE w v„ [am[e .D9Y,[[ �n ,kilo nNCME..e,�i 9m.K 4m.ut a++.y 4,61w, , JE&ENB BUCHALTER BOAT HOUSE m.A mrN j ®GradyNlinor °.°'.�"°'"EAwmke.P". ].00 YY Del Ery „ .. PPimP.Ymn4JAI]{ 493 WILLET AVENUE a tee. "IE.Wll„•1. l.:nl Isu-,"1. . l•l:nNn•ry i.:lnna'aln•,TN'uw•, I., NAPLES, FLORIDA 34108 vlKPnu�r :i R. 0.1. 0.Knp,on� r a 'Iu,1,11. NPrtm, L, D IT I I I I v C........0 Com 1'nn \Iwm 1 , SH66I 1 OT 1 u SURVEY SKETCH OF ASBUILT SURVEY LOT I ffR 5/8' &LOCK O NO ID SKETCH OF PROPOSED IMPROVEMENTS PROPOSED 10,000 LB. NOT FOR FENCE CONSTRUCTION DIRECT DRIVE ALUMINUM W£TfaCE SEAWALL - J-_---- ---THE MEAN HIGH WATER LINE Nor FoR ctwsmu£T1aN BOATLIFT NOT SET IS ALONG THE WET FACE OF NOT FOR DESIGN OR FDUVB, NOT SET THE SEAWALL WHICH IS IMPROVEMENTS OTHER THAN L3 FOUND RECESSED IN 0.4' FROM THE THOSE SHOWN, IF ANY, WATERWAYSTAKE I 7.6, 1-1 , • 3• scT -�-SET OUTER FACE OF THE SEAWALL I WERE NOT LOCATED STREET ADDRESS (100' ROW) ��\ �bJ 73' SETBACK CAP. THIS WET FACE IS THE BASIS OF' THE PROTRUSIONS SHOWN 493 WILLET AVE. PROPOSED 10,000 LB A DIRECT DRIVE ALUMINUM 34'XIO' BOATHOUSE ROOF \ N NAPLES, FLORIDA. BOA _--_ -_-_-_ ISr �_ ao• _ _ OLD WETFA - SEAWALL 2' - - - - - -- OPOSEDOCK 7. 750' S88'04'10'V. 75.00' (P) NOT S£T c� I _ -- - i ITY t:11L31VQ'1, FDH S.67'30'43'W 750mv (C) DR FOUN ab' NOT Sfl FTJ NO ID y3�CKBACK L1 NEW OR FOUND 0' �KTat4 07.7' VISID F£NC£ £U KC SETBACK SEAWALL All J q z O N H Z (u'ii 2rl p ` 00 rl O .P •TF fll nua`��r� O H UIL c4 C � N M n LU I•I EYAI III LOT 19 ~ LOT I8 p BLOCK N o BLOCK N a m IMPROVEMENTS OTHER THAN p '" p + THOSE SHOWN, IF ANY, n WERE NOT LOCATED CERTIFIED TO STEPHEN BUCHAL TER 30.0' LEGAL DESCRIPTION FIR 5/8' RIGHT OF VA SB8'28'30'V. 75.00' <C)TFSpMD s.eB 2r48'v. 65.25' (C) S88'04'10'W 85.00' (Po ACTFp SET LOT 19, BLOCK N, UNIT NO. 2 CONNOR'S 45013 S88'04'10'W. 75.00' (P) VANDERBILT BEACH ESTATES, ACCORDING TO pw THE PLAT THEREOF, RECORDED IN PLAT BOOK o 3, PAGE 17, OF THE PUBLIC RECORDS OF ' COLLIER COUNTY, FLORIDA. CENTERL1NEy — _ WILLET AVENUE QUALITY CONTROL • MEF / / 1 (60' RDW) BYDATE .J NOTE, IF APPLICABLE, FENCES SHOWN MEANDER ON OR OFF LINES (APPROX LOCATION ONLY) NOT VAUD IITHOUT SURVEYOR'S SIGNATURE AND EMBOSSED SEAL NOT A CERTIFICATION OF TITLE. ZONING, EASEMENTS OR FREEDOM OF ENCUMBRANCES. FLORIDA STATUTE 5J-17.05 (3) (c): TWO SITE BENCHMARKS REOUIRED FOR CONSTRUCTION NOTE, PROPERTY OWNER SHOULD OBTAIN WRITTEN FLOOD ZONE DETERMINATION FROM LOCAL PERMITTING, PLANNING AND BUILDING DEPARTMENT PRIOR TO ANY CONSTRUCTION PLANNING AND/OR CONSTRUCTION. CERTIFICATION THE LACS ON THIS SKETCH DO NOT COVSr17UrE OWNERSHIP COPYRIGHT 2020, FLA SURVEYS CORP. PAGE I OF 3 SEE REVERSE SIDE FOR PAGE 3 OF 3 'I N ws SCALE I" - 30' L INE TABL E Line Bearing Distance LI N88'04'10'E. 55.00' (P) H88.24'567. 5500, CC) L2 N01'55'50'W. 50.00, (P) NOl •02'45'W. 50.05' (C) L3 N.88'04'10'E. 30.00' (P) N88131155 E. 30.00, (C) L 4 N.Ol •55'50'W 170.00' (P) N01'28'05'V. 170.00' (C) MEASURED BEARINGS SHOWN ARE BASED ON STATE PLANE COORDINATES (FLORIDA EAST ZONE) AS ACQUIRED BY USING CPS TECHNOLOGY AND IS THE 'BASIS OF BEARINGS'. MEASUREMENTS LABELED AS (G) ARE THE CALCULATED CPS PLAT BEARINGS. I HEREBY CERTIFY THIS SURVEY WAS MADE UNDER MY RESPONSBLE CHARGE AND MEETS THE STANDARDS OF PRACTICE AS SET FORTH BY o T 16 m w THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS 8 MAPPERS GRAPHIC SCALE CHAPTER 5J1705-052, FLORIDA ADMINSTRATIVE CODE, PURSUANT TO SECTION 472.027 FLORIDA STATUTES. 3884 PROGRESS AVE.. SUITE 104 NOTE REVISIONS F.L.A. SURVEYS CORP. NAPLES, FL 34104 239-403-1600 FAX 403-8600 COMPLIANCE WITH F.AC. 11/19/2021 CHECK TIE 239-404-7129 239-37 5 5ASEMENT (RI (4) CIF LOCATION OF BY : SURVEY DATE 7/14/2022 PROFESSIONAL LAND SURVEYORS &MAPPERS -LB 6569 -1139 239-250-2795 239-370-1139 EASEMENTS OR RIGHT-pF-WAY OF RECORD, NO OTHER THAN THOSE ON RECORD PLAT, IS CLINTON W. FIN PE, CFN. PIS #2453 LELAND F D ySARD, PIS y3859 PROJECT N0: 9220 BONITA BEACH ROAD, STE 200 BONITA SPRINGS. FL 34135 REQUIRED, THIS INFORMATION MUST BE FURNISHED TO THE SURVEYOR AND MAPPER. MARY E. FINSTAD, CFM, PSM #5901 21-88687-SPC DRAWN BY: IDV PARTY CHIEF- MIKE NOT FOR FENCE CONSTRUCTION NOT FOR CONSTRUCTION NOT FOR DESIGN TV a I r - r- 1 I ' - I PROFESSIONAL LAND SURVEYORS & MAPPERS LB 6569 PROJECT NO. DRAWN BY: LFD IPARTY CHIEF: N/A 21-88687 PAGE 3 OF 3 83. (R) = RADIAL 84. R = RADIUS NOT VALID WITHOUT 85. RING = ITEM DETECTED BY METAL DETECTOR BUT PAGES 1 AND 2 OF 3 NOT RECOVERED 86. RNG= RANGE GENERAL NOTES 87. ROW=RIGHT-OF-WAY ABSTRACT NOT REVIEWED 88. RR SPK = RAILROAD SPIKE 89. SAT= SATELLITE DISH N = NORTH 90. SEC = SECTION S = SOUTH 91. SPK&D = SET PK WITH DISC WITH LB NUMBER 92. SIR = SET 5/8" IRON ROD WITH LB NUMBER E = EAST 93. TBM = TEMPORARY BENCHMARK W = WEST, OR ANY COMBINATION THEREOF 94. TECO= TAMPA ELECTRIC COMPANY 1. ° = DEGREES 95. TEL = TELEPHONE FACILITIES 2. ` = MINUTES WHEN USED IN A BEARING 96. TOB = TOP OF BANK 3. "= SECONDS WHEN USED IN A BEARING 97. TP = TRANSMITTER PAD 4. ` = FEET WHEN USED IN A DISTANCE 98. TUE = TECHNOLOGY UTILITY EASEMENT 5. "= INCHES WHEN USED IN A DISTANCE 99. TVR= TELEVISION RISER 6. ± _ "MORE OR LESS" OR "PLUS OR MINUS" 100. TWP= TOWNSHIP 7. A = ARC DISTANCE 101. UE = UTILITY EASEMENT 8. AC = ACRES 102. VF = VINYL FENCE 9. A/C = AIR CONDITIONING PAD 103. W = WATER SERVICE 10. AE = ACCESS EASEMENT 104. WB = WATER BOX 11. B.E. = BUFFER EASEMENT 105. WF= WOOD FENCE 12. BM = BENCHMARK 106. WPP= WOOD POWER POLE 13. BOB = BASIS OF BEARING 107. WREC= WITHLACOOCHEE RIVER ELECTRIC 14. BRG = BEARING COMPANY 15. C# = CURVE NUMBER 108. A = DELTA OR CENTRAL ANGLE OF CURVE 16. C = CALCULATED 109. DIMENSIONS ARE IN FEET AND IN DECIMALS 17. CB = CATCH BASIN THEREOF 18. CHB = CHORD BEARING 110. ELEVATIONS SHOWN HEREON ARE NAVD 1988 19. CHD = CHORD UNLESS OTHERWISE STATED 20. CLF = CHAINLINK FENCE 111. ALL PHYSICAL IMPROVEMENTS SHOWN WITHOUT 21. CM = CONCRETE MONUMENT DIMENSIONS ARE FOR INFORMATIONAL PURPOSES 22. CO = CLEAN OUT ONLY. THAT THEY DO EXIST, BUT WERE NOT 23. CONC = CONCRETE NECESSARILY MEASURED IN THE FIELD. 24. CP = CONCRETE PAD 112. NOTE: LEGAL DESCRIPTION PROVIDED BY CLIENT 25. CSW = CONCRETE SIDEWALK UNLESS OTHERWISE NOTED. 26. CTV= CABLE TV RISER 113. EASEMENTS AND RIGHT OF WAYS SHOWN ARE PER 27. CUE= COLLIER COUNTY UTILITY RECORDED PLAT OR AS FURNISHED BY THE CLIENT EASEMENT 114. FOUNDATION LINE BELOW THE SURFACE OF THE 28. D = DEED GROUND IS NOT REFLECTED 29. DE= DRAINAGE EASEMENT 115. THIS SURVEY IS NOT TO BE USED FOR 30. DH = DRILL HOLE CONSTRUCTION PURPOSES UNDER ANY CONDITION 31. DI = DROP INLET UNLESS OTHERWISE STATED 32. ELEC= ELECTRIC 116. NO UNDERGROUND INSTALLATIONS OR 33. EOP = EDGE OF PAVEMENT IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS 34. FOR = EDGE OF ROAD NOTED 35. EOW = EDGE OF WATER 117. NO INSTRUMENTS OF RECORD REFLECTING 36. F= AS LABELED OR FOUND IN THE FIELD EASEMENTS, RIGHT OF WAYS, AND/OR OWNERSHIP 37. F.A.C. = FLORIDA ADMINISTRATIVE CODE WERE FURNISHED THIS SURVEYOR EXCEPT AS SHOWN 38. FCC = FOUND CROSS CUT 118. THERE ARE NO VISIBLE ENCROACHMENTS EXCEPT 39. FCM = FOUND CONCRETE MONUMENT THOSE AS DELINEATED ON THIS PLAT OF SURVEY 40. FEMA = FEDERAL EMERGENCY 119. TIES ARE TO FIELD LINES UNLESS OTHERWISE MANAGEMENT AGENCY NOTED 41. FDH = FOUND DRILL HOLE 120. THERE MAY BE ADDITIONAL RESTRICTIONS AND/OR 42. FFE = FINISH FLOOR ELEVATION EASEMENTS THAT ARE NOT RECORDED ON SAID 43. FH = FIRE HYDRANT PLAT THAT MAY BE FOUND IN THE PUBLIC 44. FIP = FOUND IRON PIPE RECORDS OF THIS COUNTY 45. FIR = FOUND IRON ROD 121. FENCES MEANDER ON AND OFF LINE, 46. FN = FOUND NAIL APPROXIMATE LOCATION ONLY UNLESS STATED 47. FND = FOUND OTHERWISE. 48. FPK = FOUND PK NAIL 122. THE LINES ON THIS SKETCH DO NOT CONSTITUTE 49. FPK&D = FOUND PK NAIL AND DISC OWNERSHIP 50. GTE = TELEPHONE RISER 123. THE INTENT OF THIS SURVEY IS FOR TITLE 51. ILLEG. = ILLEGIBLE LB OR PSM NUMBER TRANSFER ONLY UNLESS STATED OTHERWISE. 52. LB = LICENSED BUSINESS 124. FLORIDA STATUTE : TWO SITE BENCHMARKS ARE 53. LBE = LANDSCAPE BUFFER EASEMENT REQUIRED FOR CONSTRUCTION. 54. LME = LAKE MAINTENANCE EASEMENT 125. THIS SURVEY DOES NOT REFLECT OR DETERMINE 55. LP = LIGHT POLE OWNERSHIP. 56. M = MEASURED 126. 121. F.E.M.A. FLOOD HAZARD MAPPING: THIS DATE 57. ME = MAINTENANCE EASEMENT PRODUCT WAS NOT DESIGNED TO MAKE PRECISE IN/OUT 58. MH = MANHOLE FLOOD RISK DETERMINATIONS. THIS PRODUCT IS NOT 59. NAVD 1988 = NORTH AMERICAN VERTICAL SUITABLE FOR ENGINEERING APPLICATIONS AND CANNOT DATUM OF 1988 BE USED TO DETERMINE ABSOLUTE DELINEATIONS OF 60. NGVD 1929 = NATIONAL GEODETIC FLOOD BOUNDARIES. CALL 1-877-FEMAMAP OR EMAIL A VERTICAL DATUM OF 1929 MAP SPECIALIST AT: 61. NO ID = NO IDENTIFYING MARKINGS HTTP://WWW.FEMA.GOV/PLAN/PREVENT/FHM/TSD EMAP.SHT 62. (NR) = NON -RADIAL PROPERTY OWNER SHOULD OBTAIN WRITTEN FLOOD ZONE 63. NTS= NOT TO SCALE DETERMINATION FROM LOCAL PERMITTING, PLANNING 64. OHP= OVERHEAD POWER AND BUILDING DEPARTMENT PRIOR TO ANY 65. OHU = OVERHEAD UTILITY LINE CONSTRUCTION PLANNING AND/OR CONSTRUCTION 66. O.R. = OFFICIAL RECORD BOOK 127. IN COMPLIANCE WITH F.A.C. 5J-17.052(2)(D)(4) - IF 67. P = PLAT LOCATION OF EASEMENTS OR RIGHT-OF-WAY OF 68. PC = POINT OF CURVATURE RECORD, OTHER THAN THOSE ON RECORD PLAT, IS 69. PCC = POINT OF COMPOUND CURVATURE REQUIRED, THIS INFORMATION MUST BE 70. PCP = PERMANENT CONTROL POINT FURNISHED TO THE SURVEYOR AND MAPPER. 71. PG = PAGE 128. IF APPLICABLE, FENCES SHOWN MEANDER ON OR 72. PI = POINT OF INTERSECTION OFF LINES (APPROXIMATE LOCATION ONLY) 73. PK&D = PARKER KALON NAIL AND DISC 129. ARCHITECTURAL FEATURES, SUCH AS FURRING 74. PLS = PROFESSIONAL LAND SURVEYOR STRIPS, SIDING, CORNICES, STUCCO, ETC., OUTSIDE 75. POB = POINT OF BEGINNING THE LINE OF THE STRUCTURE HAVE BEEN TAKEN 76. POC = POINT OF COMMENCEMENT INTO ACCOUNT WHEN GIVING TIES FROM THE 77. PP = POWER POLE STRUCTURE TO THE LOT LINES. 78. PRC = POINT OF REVERSE CURVE 130. ATTENTION IS DIRECTED TO THE FACT THAT THIS 79. PRM = PERMANENT REFERENCE MONUMENT SURVEY MAY HAVE BEEN REDUCED OR ENLARGED IN 80. PSM= PROFESSIONAL SURVEYOR AND SIZE DUE TO REPRODUCTION. THIS SHOULD BE TAKEN MAPPER INTO CONSIDERATION WHEN OBTAINING SCALED 81. PU & DE = PUBLIC UTILITY & DRAINAGE DATA. EASEMENT 82. PUE = PUBLIC UTILITY EASEMENT