Loading...
HEX Final Decision 2021-27HEX NO. 2021-27 HEARING EXAMINER DECISION DATE OF HEARING. July 8, 2021 PETITION. PETITION No. BDE-PL20190000674 - Request for an after -the -fact 4.4-foot boat dock extension and boathouse over the maximum 20 feet allowed by Section 5.03.06.E.1 of the Collier County Land Development Code for waterways 100 feet or greater in width, to allow a boathouse and boat docking facility with two boat slips each with a boat -lift, one for a 19- foot vessel and the other for two personal watercraft, to protrude a total of 24.4 feet into a 900f feet wide waterway for the benefit of property described as Lot 151, Isles of Capri No. 2, also described as 166 Tahiti Circle, in Section 32, Township 51 South, Range 26 East, Collier County, Florida. GENERAL PURPOSE FOR THE PETITION. The existing boathouse and dock were re -built, having been destroyed by Hurricane Irma, as authorized under building permit No. PRBD20180104701. Upon completion of construction, it was determined that the maximum allowable protrusion of 20 feet had been exceeded by 4.4 feet as measured from the most restrictive point, the property line as per LDC Section 5.03.06.C.1. The boathouse measures 13.8 feet by 20 feet and only covers the primary slip. The dock facility satisfies the 15-foot side yard requirement for lots of 60 feet or greater in width. Approval of this boat is required for the issuance of a Certificate of Completion. STAFF RECOMMENDATION. Approval with conditions. FINDINGS. 1. The Hearing Examiner has jurisdiction over this Petitioner pursuant to Sec. 2-87(4) of the Collier County of Ordinances, Sec. 8.10.00 of the Land Development Code, and Chapter 9 of the County Administrative Code. 2. The public hearing for this Petition was properly noticed and conducted in accordance with all County and state requirements. 3. The public hearing was conducted electronically and in -person in accordance with Emergency/Executive Order 2020-04. Page 1 of 7 4. The Petitioner and/or Petitioner's representative executed the Hybrid Virtual Quasi -Judicial Public Hearing Waiver related to conducting the public hearing electronically and in -person. 5. The County representative introduced the Petition and staff recommendations, followed by Petitioner and/or Petitioner's representative, and then public comment. There were no objections to the Petition at the public hearing. 6. The County's Land Development Section 5.03.06.H. lists the criteria for dock facility extensions. The Hearing Examiner may approve, approve with conditions, or deny a boat dock extension request if it is determined that at least four (4) of the five (5) primary criteria, and at least four (4) of the six (6) secondary criteria have been met.' Primary Criteria: 1. Whether the number of dock facilities and/or boat slips proposed is appropriate in relation to the waterfront length, location, upland land use and zoning of the subject property. Consideration should be made of property on unbridged barrier islands, where vessels are the primary means of transportation to and from the property. (The number should be appropriate; typical single-family use should be no more than two slips; typical multi- family use should be one slip per dwelling unit; in the case of unbridged barrier island docks, additional slips may be appropriate.) Criterion met. The record from the public hearing demonstrates that the property is located within a residential single-family zoning district and comprises a single boat dock facility with two boatlifts, each establishing a slip; one to accommodate a 19 foot vessel and the other two personal watercraft. The proposed dock (dock and vessel combined) protrudes 24.4 feet from the property line which has been identified as the most restrictive point per LDC Section 5.03.06. C.1. 2. Whether the water depth at the proposed site is so shallow that a vessel of the general length, type, and draft as that described in the petitioner's application is unable to launch or moor at mean low tide (MLT). (The petitioner's application and survey should establish that the water depth is too shallow to allow launching and mooring of the vessel(s) described without an extension.) Criterion not met. The record at the public hearing demonstrates that the plotted property line is located on the landward side of the seawall and there is riprap along the seawall further restricting where a boatlift could be installed, therefore a BDE would be required for any proposed dock and boatlift. The Petitioner failed to specifically address the criterion with respect to water depth. Although the applicant has provided a cross section providing the MHW and MLW measures it does not demonstrate how the vessel/PWC are impacted. 'The Hearing Examiner's findings are italicized. Page 2 of 7 3. Whether the proposed dock facility may have an adverse impact on navigation within an adjacent marked or charted navigable channel. (The facility should not intrude into any marked or charted navigable channel thus impeding vessel traffic in the channel.) Criterion met. The record at the public hearing demonstrates that the as -built boat dock does not protrude into a marked navigable channel and is consistent with other docks along the subject shoreline. 4. Whether the proposed dock facility protrudes no more than 25 percent of the width of the waterway, and whether a minimum of 50 percent of the waterway width between dock facilities on either side is maintained for navigability. (The facility should maintain the required percentages.) Criterion met. The record at the public hearing reflects that the as -built dock facility protrudes 24.4 feet into a waterway that is 900± feet wide which is approximately 3.3% of the width of said waterway. 5. Whether the proposed location and design of the dock facility is such that the facility would not interfere with the use of neighboring docks. (The facility should not interfere with the use of legally permitted neighboring docks.) Criterion met. The record at the public hearing reflects that the existing dock facility provides 20.6 foot and 49 foot setbacks which is greater than the required 15 foot side/riparian setback. Secondary Criteria: 1. Whether there are special conditions not involving water depth, related to the subject property or waterway, which justify the proposed dimensions and location of the proposed dock facility. (There must be at least one special condition related to the property; these may include type of shoreline reinforcement, shoreline configuration, mangrove growth, or seagrass beds.) Criterion met. The record at the public hearing reflects that the subject property line is a convex curve. LDC Section 5.03.06. C.1, measurement of dock protrusion, requires protrusion be measured from the most restrictive of several identified points; in this case, maximum protrusion is measured from the property line which is landward of the seawall. Additionally, the shoreline comprises a large rip -rap area that extends landward of the property line as evidenced by Building Permit No. PRBD20150723986. Together, these conditions require the dock facility protrude further into the waterway to reach adequate water depths. 2. Whether the proposed dock facility would allow reasonable, safe access to the vessel for loading/unloading and routine maintenance, without the use of excessive deck area not directly related to these functions. (The facility should not use excessive deck area.) Page 3 of 7 Criterion met. The record from the public hearing reflects that the existing dock facility consists of 406 square feet of decking. The proposed dock facility provides sufficient decking for safe access to the vessel and two PWC's and further allows for other recreational activities such as fishing, kayaking, and paddle boarding. 3. For single-family dock facilities, whether the length of the vessel, or vessels in combination, described by the petitioner, exceeds 50 percent of the subject property's linear waterfront footage. (The applicable maximum percentage should be maintained.) Criterion not met. The record from the public hearing reflects that the shoreline is 102f feet. The dockfacility has been designed to accommodate a 19 foot vessel and two PWC's, therefore the 50 percent limitation has been exceeded. 4. Whether the proposed facility would have a major impact on the waterfront view of neighboring property owners. (The facility should not have a major impact on the view of a neighboring property owner.) Criterion met. The record from the public hearing reflects that the existing boathouse and boat dock facility are well within the required 1 S foot side/riparian setbacks. Additionally, a review of aerial photography indicate that the subject property is located on a convex curve and that adjoining properties tend not to directly face said riparian lines. 5. Whether seagrass beds will be impacted by the proposed dock facility. (If seagrass beds are present, compliance with subsection 5.03.06.J of the LDC must be demonstrated.) Criterion met. The record from the public hearing reflects that the submerged resources survey reveals no seagrass beds are located within 200 feet of the proposed dock facility, there will be no impact to seagrass beds. 6. Whether the proposed dock facility is subject to the manatee protection requirements of subsection 5.03.06(E)(11) of this Code. (If applicable, compliance with section 5.03.06(E)(11) must be demonstrated. Criterion is not applicable. Based on the record at the public hearing the provisions of the Collier County Manatee Protection Plan do not apply to individual docks behind individual residences. Boathouse Criteria: 1. Minimum side setback requirement: Fifteen Feet. Criterion met: The record from the public hearing reflects that the boathouse will not exceed mandatory side yard/riparian setback requirements. Page 4 of 7 2. Maximum protrusion into waterway: Twenty-five percent of canal width or 20 feet, whichever is less. The roof alone may overhang no more than 3 feet into the waterway beyond the maximum protrusion and/or side setbacks. Criterion met: The record from the public hearing reflects that the maximum protrusion will be extended to 24.4 feet as measured from the property line and the waterway width is 900± feet; therefore, the boathouse will protrude into 2.71 percent of the waterway. 3. Maximum height: Fifteen feet as measured from the top of the seawall or bank, whichever is more restrictive, to the peak or highest elevation of the roof. Criterion met: The record from the public hearing reflects that the proposed height is 15 feet above the seawall/top of deck. 4. Maximum number of boathouses or covered structures per site: One. Criterion met. The record from the public hearing reflects that only one boathouse is to be built on this property. 5. All boathouses and covered structures shall be completely open on all 4 sides. Criterion met. The record from the public hearing reflects that the boathouse will be open on all four sides. 6. Roofing material and roof color shall be the same as materials and colors used on the principal structure or may be of a palm frond "chickee" style. A single-family dwelling unit must be constructed on the subject lot prior to, or simultaneously with, the construction of any boathouse or covered dock structure. Criterion met. The record from the public hearing reflects that the roofing material and color of the proposed boathouse will match that of the existing single-family residence serving as the principal structure at this location. 7. The boathouse or covered structure must be so located as to minimize the impact on the view of the adjacent neighbors to the greatest extent practical. Criterion met. The record from the public hearing reflects that the boathouse is located within the required side/riparian setbacks and is already existing. Therefore, no new impacts to the adjacent property owners will result from this project. ANAL NSIS. Based on a review of the record including the Petition, application, exhibits, the County's staff report, and hearing comments and testimony from the Petitioner and/or the Petitioner's representative(s), County staff and any given by the public, the Hearing Examiner finds that there Page 5 of 7 is enough competent, substantial evidence as applied to the criteria set forth in Section 5.03.06.11 of the Land Development Code to approve Petition. DECISION. The Hearing Examiner hereby APPROVES Petition Number BDE-PL20190000674, filed by Jeff Rogers of Turrell, Hall & Associates representing Robert Moses, Amy Moses and Amy Taylor, with respect to the property described as 166 Tahiti Circle, further described as Lot 151, Isles of Capri No 2, in Section 32, Township 51 South, Range 26 East, Collier County, Florida, for the following: • An after -the -fact boathouse and 4.4-foot boat dock extension over the maximum 20 feet allowed by Section 5.03.06.E.1 of the Land Development Code for waterways 100 feet or greater in width, to allow a boathouse and boat docking facility with two boat slips each with a boat -lift, one for a 19-foot vessel and the other for two personal watercraft, to protrude a total of 24.4 feet into a 900± feet wide waterway for the benefit of the subject property. Said changes are fully described in the Dock Facility Plans and As -Built Survey attached as Exhibit "A" and are subject to the condition(s) set forth below. ATTACHMENTS. Exhibit A — Dock Facility Plans and As -Built Survey LEGAL DESCRIPTION. 166 Tahiti Circle, further described as Lot 151, Isles of Capri No 2, in Section 32, Township 51 South, Range 26 East, Collier County, Florida. CONDITIONS. 1. All other applicable state or federal permits must be obtained before commencement of the development. 2. An ST permit must be sought and approved prior to obtaining a Certificate of Completion for the boathouse and dock facility. Typically, ST permits are required at the time of permitting; however, in this case, an ST permit was not originally required as the dock facility was to be constructed within the same footprint as that previously approved by Permit No. PRBD20150825947. Any such approval is to be based upon the Proposed Aerial, sheet 03 of 10, and the As -Built Survey contained within Exhibit "A". DISCLAIMER. Pursuant to Section 125.022(5) F.S., issuance of a development permit by a county does not in any way create any rights on the part of the applicant to obtain a permit from a state or federal agency Page 6 of 7 and does not create any liability on the part of the county for issuance of the permit if the applicant fails to obtain requisite approvals or fulfill the obligations imposed by a state or federal agency or undertakes actions that result in a violation of state or federal law. APPEALS. This decision becomes effective on the date it is rendered. An appeal of this decision shall be done in accordance with applicable ordinances, codes and law. RECORD OF PROCEEDINGS AND EXHIBITS: SEE CLERK OF COURT, MINUTES AND RECORDS DEPARTMENT. DECISIONS OF THE HEARING EXAMINER FOR VARIANCES, CONDITIONAL USES, AND BOAT DOCK EXTENSIONS SHALL BE NOTED ON THE ZONING MAP FOR INFORMATIONAL PURPOSES. August 5, 2021 Date Andrew Dickman, Esq., AICP Hearing Examiner Page 7 of 7 EXHIBIT "A" N ■ s SUBJECT PROPERTY TAMPA 1 FT. MYER APL S MIAMI o' s KEY WEST -0 CITY COLLIER COUNTY SUBJECT PROPERTY SITE ADDRESS: <> 166 TAHITI CIRCLE NAPLES, FL 34113 NOTES: <> THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE. <> LATITUDE: N 26.981449 <> LONGITUDE: W 81.733547 77" VICINITY MAP COUNTY AERIAL DESIGNED JR 11, RMJ 10-29-19 .R PAGES 01-09 Turrell, Hall & Associates, Inc. 1 6 6 TA H I-F I C I R C L E AT BY RMJ D: 06-17-19 3 Marine & Environmental Consulting JOB NO 19071 14, 3584 Exchange Ave. Naples, FL 34104-3732 LOCATION MAP SHEET NO. W OF 10 15 Emad: dma@wnell-moci3les-com Phone: (239) 643-0166 Fax: (239) 643-6632 _,.,.a.,r.,,,.., .:...... ..... ... ..,...., _ SECTION-32 TOWNSHIP- 51S RANGE-26E I THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE. ALL DATUM SHOWN HEREON IS REFERENCED TO MLW SURVEY COURTESY OF "COURT GREGORY" SURVEY DATED 1--19 • APPLICANT OWNED SHORELINE (APPX LF) 102 EXISTING OVERWATER STRUCTURE (APPX SF) SSS WIDTH OF WATERWAY. MHW TO MHW (APPX) Soo TIDAL DATUM .. MHW (NAVD)• .OA2' JOHNSON BAY APPROXIMATE RIPARIAN LINE � I r� EXISTING LIFT ,� \ ♦ ';,a SUBJECT PROPERTY f0 20 4b SCFILE9NxEfr EXISTING \ SITE ADDRESS: DOCK & 166 TAHITI CIRCLE BOATHOUSE NAPLES, FL 34113 13.8'x20' a 2' WIDE /p SEAWALL CAP y APPROXIMATE RIPARIAN LINE 110, PU Terrell, Hall &Associates, Inc. Marine & Environmental Consulting 3584 Exchange Ave. Naples, FL34104-3732 Em3)I:d108(q)umF-a=ia(esoom Phone: (239) 643-0166 Fax: (239) 643-6632 1 6 6 TA H I T I CIRCLE EXISTING AERIAL . , . .. ..........:._......,.._,_,...:,_....,.._..._......_- 2 RMJ 10.29 19 JR ADD DIMS, REV NOTE BOX ORAWN BY RMJ CREATED 9 3 JOB NO 9077 19031 4 . SHEET NO 02OF10 15 SECTION-32 TOWNSHIP- 51S RANGE-26E a O� APPROXIMATE RIPARIAN LINE JOHNSON BAY APPROXIMATE RIPARIAN LINE r• A4k PROPOSED LIFT y PROPOSED BOATHOUSE 13.8'x20' � SUBJECT PROPERTY — PROPOSED DOCK AND LIFT 2' WIDE SEAWALL CAP N AM�k S fo 20 ,. sCF(CE9N�EE? SITE ADDRESS: 166 TAHITI CIRCLE NAPLES, FL 34113 NOTES: THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE. ALL DATUM SHOWN HEREON IS REFERENCED TO MLW SURVEY COURTESY OF "COURT GREGORY" • • SURVEY DATED 104749 APPLICANT OWNED SHORELINE (APPX LF) 102 EXISTING OVERWATER STRUCTURE (APPX SF) S35 WIDTH OF WATERWAY MHW TO MHW (APPX) S00' TIDAL DATUM .• MHW (NAVD:- +OA2' • • MLW(NAVD;=-1.5.1' • PROPOSED OVERWATER STRUCTURE (APPX SF) 512 • TOTAL OVERWATER STRUCTURE (APPX SF) 512 • TOTAL PROTRUSION FROM PROPERTY LINE. 24.1' Terrell, Hall &Associates, Inc. Marine & Environmental Consulting 3584 Exchange Ave. Naples,FL34104-3732 Email:=a(alomell4%odaWs.COm Phme: (239) 643-0166 Fax:(239) 643-6632 1 6 6 TA H I-F I C I R C L E PROPOSED AERIAL DESIGNED JH 1 RMJ 10.29.19 JR REV NOTE BOX EDY �;T.19 3_ CREATED JOa NO 19031 1 SHEET NO m WOF10 5 SECTION-32 TOWNSHIP- 51S RANGE-26E APPROXIMATE RIPARIAN LINE X1-8.2 r dim . • v� -13.4X 104 A •� . 13 3 �L,04` k� ° 3 ' PROPOSED LIFT -12. b'e 12 9 106� _ � - aA - -13 2X 1 2 _10 -6 2x f -2-1. JOHNSON BAY Ate. APPROXIMATE RIPARIAN LINE I N S fo 20 40 SCACE9N%EET . PROPOSED BOATHOUSE bA 3.8'x20' SUBJECT PROPERTY \ 0 PROPOSED DOCK AND LIFT SITE ADDRESS: 166 TAHITI CIRCLE �!F NAPLES, FL 34113 2' WIDE SEAWALL CAP NOTES: THESE DRAWINGS ARE FOR PERMITTING PURPOSES ONLY AND ARE NOT INTENDED FOR CONSTRUCTION USE ALL DATUM SHOWN HEREON IS REFERENCED TO MLW SURVEY COURTESY OF 'COURT GREGORY" • • SURVEY DATED 10-07-19 APPLICANT OWNED SHORELINE (APPX LF) 102 EXISTING OVERWATER STRUCTURE (APPX SF) S35 WIDTH OF WATERWAY MHW TO MHW (APPX) 900' TIDAL DATUM .. MHW (NAVD)= •0.42' • • MLW (NAVD)- .1.67' PROPOSED OVERWATER STRUCTURE (APPX SF1 612 TOTAL OVERWATER STRUCTURE (APPX SF) 512 TOTAL PROTRUSION FROM PROPERTY LINE 24.4' ........ +n I I I RMJ 10-29-19 1 JR I NEW PAGE Turrel , Hall &Associates, Inc. '1 6 6 TA H I-F I C I R C L E DRAWN CREATED az2.19 3 Marine & Environmental Consulting JOB NO 19031 14. )M�t 3584ExchangeAve. Naples, FL34104-3732 PROPOSED AERIAL WITH DEPTHS SHEET NO 04OF10 15 EnWl:wm@h=U-miates.com iateS.com Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION- 32 TOWNSHIP- 51 S FLANGE- 26 E 11 PROPOSED BOATHOUSE NOT EXTEND OUT PAST THE PROPOSED DOCK NOTE: ROOFING MATERIAL AND ROOF COLOR SHALL BE THE SAME AS MATERIALS AND COLORS USED ON PRINCIPAL STRUCTURE. 3' MHW = +0.42' NAVD 88 i MLW = -1.63' NAVD 88 _ k 20' ROOF EXTENDS 20' MAX FROM MHWL PROPOSED LIFT 24.4' TO PROPERTY LINE — 12 5' BOAT LIFT L — k V Turrell, Hall & Associates, Inc. DRAWN GNED RZ Marine &Environmental Consulting '1 6 6 TA H I T I C I R C L E CREATED B& JOB NO 9 3584 Exchange Ave. Naples, FL34104-3732 CROSS SECTION AA SMEETNO us 3' SCAfE 9NRiET ALL PILES TO BE PVC WRAPPED FROM 12" ABOVE MHWL TO 6" BELOW SUBSTRATE PROPERTY LINE -PROPOSED DOCK EXISTING SEAWALL Email: tuoa@Imrell•assoclates.com Phone: (239) 643-0] 66 Fax: r.239) 643-6632 SECTION-32 TOWNSHIP- 51 S RANGE- 26 E 20' 3' 3' PROPOSED BOATHOUSE a s 4 8 NOT EXTEND OUT PAST THE PROPOSED DOCK ROOF EXTENDS 20' MAX SC711E9N�E£T uFROM 3' MHWL ' NOTE: ROOFING MATERIAL PROPOSED LIFT AND ROOF COLOR SHALL BE THE SAME AS 24 a' TO PROPERTY LINE o MATERIALS AND PROPERTY i COLORS USED ON ia' BOAT LIFT LINE '- PRINCIPAL STRUCTURE. 0 n PROPOSED n DOCK n (- EXISTING S 3 OEM! MM=:;= SEAWALL MHW=+0.42' NAVD 88 _ -1.63' NAVD 88 MLW = ALL PILES TO BE PVC WRAPPED FROM 12" ABOVE MHWL TO 6" BELOW SUBSTRATE Turrell, Hall & Associates, Inc. DESIGNEBY D R 1 Marine &Environmental Consulting '1 6 6 TA H I T I C I R C L E DRAWN E a3;5-19 JOB NO 19031 3584 Exchange Ave. Naples, FL34104-3732 CROSS SECTION BB SHEET NO 060F10 1 Email: wm@mmll-associates.com Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION-32 TOWNSHIP- 51 5 RANGE- 26 E 81 A ■YS ~� WO 25 k 1 e% lk 1,x= v .. . _*Ar NOTE: THE DIMENSIONS SHOWN ARE APPROXIMATE / `" AND ARE TAKEN FROM THE AERIAL IMAGE. - - ` DESIGNED JR Terrell, Hall &Associates, Inc. '1 6 6 TA H I T I C I R C L E DRAWN BY: ; -11�Marine & Environmental Consulting JOB NO. D6-17 a 3584 Exchange Ave. Naples, Fl, 34104-3732 ADJACENT DOCKS SHEET NO 07OF10 B aft NOTE BOX Email: tuna i#anell-associates.com Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION- 32 TOWNSHIP- 51 S RANGE- 26C r S c 50 +oo zoc7 SCFICE9N-FET ti• 1-7 ,r SUBJECT PROPERTY L . < �. �A U 1 n• cJutrt F_ �r -77 IF 4 ST OVERLAY �qq�i rrJJ 40 DESIGNED: 'JR 1. V• RMJ 10-29-19 JR REV. NOTE BOX Turrell, Hall & Associates, Inc. 1 66 TA H I T 1 CIRCLE CREA DRAWN RMJ 3 JOB NO.: 19031 4, OE17-19 Marine & Environmental Consulting 7!374ExC ge Ave. Naples, FL34104-3732 ST OVERLAY MAP SHEET NO,: 090F10 5. : Email: Wm@t=U-miata.com Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION-32 TOWNSHIP- 5 I S RANGE- 266 / /If If If NO SEAGRASSES WERE OBSERVED GROWING y �` K WITHIN 200 FT OF THE PROPOSED PROJECT i ; in N A r 20 40 81 SC7lCE9N�EET SUBJECT PROPERTY I*t DESIGNED', JR I 1 I RMJ 10.29-19 JR REV. NOTE BOX Terrell, Hall &Associates, Inc. '1 6 6 TA H I T I C I FR C L E Dy 06-17.19 3 Marine & Environmental Consulting JOB NO. 19031 14. 3584 Exchange Ave. Naples, FL34104-3732 SUBMERGED RESOURCE SURVEY SHEET NO 09OF10 5. Emai1:tmla(4ft=H-&=iatmoom Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION-32 TOWNSHIP— 51S RANGE-26E rb 900, NOTE: THE DIMENSIONS SHOWN ARE APPROXIMATE AND ARE TAKEN FROM THE AERIAL IMAGE. SUBJECT PROPERTY 4 roo 200 400 SC1lCE sN�EE'i DESIGNED JR I I I RMJ I W-29-19 I JR I NEW PAGE Terrell, Hall &Associates, Inc. '1 6 6 TA H I T I C I R C L E CDRAWNREATED R0.29-19 Marine & Environmental Consulting JOB NO: 19071 4, 3584 Exchange Ave. Naples, FL34104-3732 WIDTH OF WATERWAY SHEET NO, 100F10 15 1- Emafl:Uu@UmH-amiates.com Phone: (239) 643-0166 Fax: (239) 643-6632 SECTION- 32 TOWNSHIP- 51 5 RANGE- 26E SCALE 1" = 30' CURVE TABLE CURVE LENGTH RADIUS I DELTA CHORD DIR HO C1 102-08 195.00129'b940' S15.WW"W 100.92 C2 44.50 85.00 2VW40" S1S'40$M 43.99 SPOT ELEVATIONS SHOWN ARE BASED UPON NAVD'SS .IUX _ _._FDDH BOUNDARY INFORMATION FURNISHED BY CLIENT. 76AX / TIx+oo / -14D X / \ i X6E f.0 \+✓ LINES -I 2X THE MHW & M�OF ABUT FS+n_ SEAWALL PANE. / \ \ .496-, VVIOOO �'6g \ l DOCK (ELIN."2N) 422 sa >4.X V/ �� 421- `'°`„x / PWROVEMENTS NOT SHOWN) NOTE: RIPRAP WAS FOUND ALONG g LOT 151 ENTIRE LENGTH OF THE SUBJECT / ?' PARCEL CONTAINS 0.19 ACRES OF PROPERTY OUT TO ABOUT 15 FEETw / LAND MORE OR LESS. JOHNSON BAY Zft WIDE CONC SEAWALL / CAP / (08 TO FACE OF NW18'34"W VINYL SEAWALL PANEL) 110.2U' (M) (CAP E.EV.132) ` N89°19'00"W SEAWAAL' LIN 110.00' (P) (MODS) LOT 150 LOT 152 y F81C BAY (NO 0) 0) SENCHOM FP*0IN 7 VALLEY GUTTER ELEV. • 3.35 l FM (NO l)n WOIDO) N89°19'00'W� 30.00' (P) a _ W W v� Q�wa���� V O �H3a 0 1"' Q m_j _V U FPp# p#o 8) n NOTES: 1.THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF TAHITI ST (P) AS SHOWN IN PLAT BOOK 3 PAGE 48 OF COLLIER COUNTY, BEING NORTH 00' 41- W EAST 2.IMPROVEMENTS OTHER THAN THOSE SHOWN ARE NOT A PART OF THIS SURVEY 3.SAID DESCRIBED LAND IS SUBJECT TO ALL SUBDIVISION REGULATIONS, RESERVATIONS, RESTRICTIONS, ZONING AND RIGHTS -OF- WAY OF RECORD. 4.DATE OF FIELD SURVEY MAY 31. 2018 5 THIS SURVEY MAP IS NOT VALID WITHOUT THE SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES B.SUSSURFACE AND ENVIRONMENTAL CONDITIONS WERE NOT EXAMINED AS A PART OF THIS SURVEY NO STATEMENT IS MADE CONCERNING THE EXISTENCE OF UNDERGROUND OR OVERHEAD CONTAINERS. UTILITIES OR FACILITIES THAT MAY AFFECT THE USE OR DEVELOPMENT OF THIS PROPERTY. 7.ELEVATIONS SHOWN ARE BASED ON NA V D DATUM OF 1988 DESCRIPTION OF BENCHMARK IS AS FOLLOWS. FPKND IN GUTTER BETWEEN RESVS 180188 TAHITI CIR ELEV = 3 W &SUBJECT PROPERTY IS SITUATED IN FLOOD ZONE' *AS INDICATED ON FEMA FLOOD ZONE MAP PANEL NO WA DATED: BASE ELEVATION DETERMINED AT NIA 91,10 TITLE OPINION OR ABSTRACT TO THE SUBJECT PROPERTY HAS BEEN PROVIDED. ALL INFORMATION HAS BEEN SUPPu ED BY THE CLIENT. IT IS POSSIBLE THAT THERE ARE DEEDS EASEMENTS, OR OTHER INSTRUMENTS (RECORDED OR UNRECORDED) WHICH MAY AFFECT THE SUBJECT PROPERTY NO SEARCH OF THE PUBLIC RECORDS HAS BEEN MADE BY THE SURVEYOR. 10. THE PURPOSE OF THIS SURVEY IS TO SHOW THE PROPOSED DOCK LOCATION WITH RESPECT TO THE PLATTED SUBJECT PROPOSERTY PROPERTY LINES ARE SHOWN AS PLAT Q • FOUND (-) IRON ROD ( SURVEYOR ID a) (FIR) Q • SET 1I2' IRON ROD (PSM 08004XSIRC) ■ • SET 4' X 4" CONCRETE MONUMENT (PSM 08004XSCM) El • FOUND CONCRETE MONUMENT (SURVEYOR ID O)(FCM) *-BENCHMARK (FOUND OR SET) RAN • RIGHT OF WAY(R.O.W.) Q • FOUND NAIL OR PK NAIL AND DISC ( SURVEYOR ID 0) (FIR) Q • SET PK NAIL AND DISC (PSM 08004) (SPKN&D) FD. • FOUND FN&TT • FOUND NAIL AND TIN TAB BM • BENCHMARK P.C.P. • PERMANENT CONTROL POINT M P.RM. • PERMANENT REFERENCE MONUMENT (n CBS -CONCRETE BLOCK & STUCCO FF • FINISHED FLOOR (PG) • PAGE CATV-CABLE TV CMP • CORRUGATED METAL PIPE (M) • FIELD MEASUREMENT U.T.S.- UNITED TELEPHONE RISER (P) OR (D) • PLAT OR RECORDED(DEED) MEASUREMENT (C) • CALCULATED MEASUREMENT CONIC • CONCRETE (PB) • PLAT BOOK LME • LAKE MAINTENANCE EASEMENT R.C.P. • REINFORCED CONCRETE PIPE PROP • PROPERTY C.L.• CENTERLINE T.O.B. • TOP OF BANK UE • UTILITY EASEMEN DE - DRAINAGE EASEMENT CUE • COUNTY (U.EJ LBE • LANDSCAPE BUFFER EASEMENT ELEC • ELECTRIC PUE = PUBLIC UTILITY EASEMENT SWE - SIDEWALK EASEMENT MAP OF ASBUILT SURVEY (DOCK IMPROVEMENT ONLY) LOT 151 OF ISLES OF CAPRI NO. 2 AS RECORDED IN PLAT BOOK 3 PAGE($) 46 OF THE PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA 166 TAHITI CIRCLE THIS SURVEY IS PREPARED FOR: TURRELL, HALL & ASSOCIATES CERTIFICATION: I CERTIFY THAT THIS SURVEY WAS MADE UNDER MY DIRECTION AND THAT IT MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS IN CHAPTER 5J.17, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION "ERTIFICATION OF TITLE ZONING, EASEMENTS OR OM OF ENCUMBRANCES ,.u.w.o-cdn SIGNED COURT H. GREGORY PSM #6004 DATE 10/0712019 DATE OF FIELD SURVEY 05-31-2018 ADDED WATER DEPTH ELEVATIONS DATE OF REVISION 10-03-2019 PSM # 6004 LB # 7112 CC.G.S. Gregory Surveying, Inc. 761 Teton Court Naples, Florida 34104 (239)643-7845 office Date 10/07/2019 cgs6004@oomcast.net Job # EN40152M2 (239)272-3707 cell Fb M1-37 Pg 78