Loading...
Backup Documents 07/13/2021 Item #17A �,t r rl, 1 7 A COLLIER COUNTY FLORIDA C 14,..r_�' REQUEST FOR LEGAL ADVERTISING OF PUBLIC HEARINGS .' C, -1.To: Clerk to the Board: Please place the following as a: fits ® Normal legal Advertisement ❑ Other: (Display Adv,,location,etc.) Originating Dept/Div: Public Utilities Engineering Person: Tom Chmelik,Director Date: 6/22/21 Petition No.(If none,give brief description): Resolution—amendments to Utilities Standards Manual Petitioner: (Name&Address): n/a Name&Address of any person(s)to be notified by Clerk's Office: (If more space is needed, attach separate sheet) Hearing before BCC BZA Other Requested Hearing date: (Based on advertisement appearing 10 days before hearing.)July 13,2021 (ad to run no later than Wednesday,June 30,2021) Newspaper(s)to be used: (Complete only if important): ® Naples Daily News ❑ Other ❑Legally Required Proposed Text: (Include legal description & common location & Size): A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA,AS THE GOVERNING BODY OF COLLIER COUNTY,FLORIDA AND EX- OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT,APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DISTRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COINCIDE WITH THE COMPANION AMENDING ORDINANCE. Does Petition Fee include advertising cost?❑ Yes ❑ No If Yes,what account should be charged for advertising costs: PO#4500211329 (Acct.No.408-210155) Revievd by. , 6/TA i Diviii n Administrator or Designee Date List Attachments: Resolution DISTRIBUTION INSTRUCTIONS A. For hearings before BCC or BZA: Initiating person to complete one copy and obtain Division Head approval before submitting to Clerk's Office for processing. Note: If legal document is involved,be sure that any necessary legal review, or request for same,is submitted to County Attorney before submitting to Minutes& Records. The Manager's office will distribute copies: ❑ County Manager agenda file: to ❑ Requesting Division ❑Original Clerk's Office B. Other hearings: Initiating Division head to approve and submit original to Clerk's Office,retaining a copy for file. FOR CLERK'S OFFICE USE O Y: Date Received: ! dd- ?/ Date of Public hearing: 7 , - r( Date Advertised: (a '!XJ c?-1 1 7 A � # RESOLUTION NO. 2021 - A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DISTRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COINCIDE WITH THE COMPANION AMENDING ORDINANCE. WHEREAS, on May 11, 2004, as Agenda Item 8 D, the Board of County Commissioners as the Ex Officio Governing Board of the Water-Sewer District (Board) concurrently adopted Collier County Ordinance No. 2004-31, entitled the Collier County Utilities Standards and Procedures Ordinance (the "Ordinance"), and the Collier County Water-Sewer District Utilities Standards Manual, ("Manual"), including all of the Manual's exhibits, and WHEREAS Ordinance No. 2004-31 is codified in Chapter 134, Article III of the Collier County Code of Laws and Ordinances; and WHEREAS, since the 2004 adoption of the Manual it has become necessary to make updates that reflect current standards in design and preparation of plans and specifications for all utilities construction projects; and WHEREAS, after input from stakeholders staff has recommended that the Board adopt this Resolution to approve amendments to the Manual as identified in the attached Exhibit "A"; and WHEREAS, Section 134-61 of the Code of Laws and Ordinances requires the Manual to be amended by Resolution of the Board under the scheduled public hearings or the summary agenda section; and WHEREAS, it is in the interest of the health, safety, and welfare that this Resolution be adopted. [Space Intentionally Left Blank] [19-EIS-04145/1637733/2] Page 1 of 2 1 7 A NOW, THEREFORE, BE IT RESOLVED BY THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT,that: The amendment of the Collier County Water-Sewer District Utilities Standards Manual as provided in attached Exhibit "A" is hereby approved and shall take effect upon the filing of Ordinance No. 2021- with the Florida Department of State. This Resolution adopted after motion, second and majority vote, this 13th day of July, 2021. BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND EX-OFFICIO ATTEST: GOVERNING BOARD OF THE COLLIER CRYSTAL K. KINZEL, CLERK COUNTY WATER-SEWER DISTRICT By: By: Deputy Clerk Penny Taylor, Chairman Approved as to Form and Legality: Derek D. Perry Assistant County Attorney `:\ [19-EIS-04145/1637733/2] Page 2 of 2 Opo 1 7 A EXHIBIT GG A » Table of Contents • Section 1 — Design Criteria, Part 3 "Wastewater Collection and Transmission Systems," Subsection 3.3 "Wastewater Pump Stations" • Section 2—Technical Specifications o Section 330130.16 "Televising and Inspection of Gravity Sewer Systems" o Section 330502 "High Density Polyethylene (HDPE) Pipe and Fittings" • Section 4—Appendices,Appendix D: Utilities Conveyance Checklist cnc� Section 1 —Design Criteria,Part 3 "Wastewater Collection and Transmission Systems," 1 7 " Subsection 3.3 "Wastewater Pump Stations" design shall consider the potential for damage or interruption of operation due to flooding. Pump station structures and electrical and mechanical equipment shall be designed to be protected from physical damage by the 100-year flood event. Pump stations shall be designed to remain fully operational and accessible during the 25-year flood event. Pump stations shall be designed to avoid operational problems from the accumulation of grit. Pump stations shall be designed to be readily accessible by maintenance vehicles, including pumper trucks, during all weather conditions. Pump stations shall be designed and located on the site to minimize adverse effects from odors, noise, and lighting. Pump stations shall be located on the site to have a minimum separation of 20 feet from the edge of the CUE for the pump station to edge of a body of water and 15 feet from the edge of the CUE for the pump station to a residential structure (including appurtenances). The effective volume of wet wells shall be based on design average flows and a filling time not to exceed 30 minutes unless the facility is designed to provide flow equalization. The pump manufacturer's duty cycle recommendations shall be utilized in selecting the minimum cycling time. Pump stations requiring a pump motor of twenty horsepower or greater shall operate by a VFD (variable frequency drive) that varies the operating speed of the pump based on wet well water levels. Pump stations shall have a compacted earth berm on three sides with 3:1 slopes to divert liquid toward the ROW. Top of berm shall be 12 inches wide and six inches higher than back of curb (with curb) or edge of pavement (without curb). Minimum berm height shall be six inches. When a pump station has a peak design flow coming into the station greater than 500 gpm, contact Public Utilities Engineering and Project Management Department for specifications. A pump station that is connected connects directly to the a County force main from a subdivision or site development, where multiple pump stations are or will be connected to said force main-(Community Pump Station),and any pump station that receives flow from one or more upstream pump stations or discharges through a force main 12 inches or larger (see FAC 62- 604.400 (2)(a)1) shall have uninterrupted pumping capability (standby diesel pump or generator) with three days of fuel storage (compliant with Technical Specification 263213) and a concrete pad for a future odor control system. Except for grinder pump stations, which require Deviation approval, no new private pump stations are allowed. Grinder pump stations are required to have a standard generator receptacle. All other pump stations shall conform to these standards and shall be conveyed to the Collier County Water-Sewer District in accordance with the utilities conveyance policies and procedures outlined in the Collier County Utilities Standards and Procedures Ordinance (Ord. No. 2004-31 as amended). All pump stations shall have water available to them. Available water means a water main is accessible in the adjacent ROW or CUE. Landscaping is not required, per these standards, to be installed around wastewater pump stations. If landscaping is provided, it shall be maintained by the developer, homeowners association, or land owner and shall NOT be located in the CUE. Landscaping, if provided, shall be located as to not block access or interfere with operations. If plant material dies, it is the responsibility of the landscaping owner to replace it. The landscaping shall be maintained to not block telemetry antenna line of site. COLLIER COUNTY WordOslGN CRITERIA are deletions; words underlined are additions. Page 16 of 19 S 17A Section 2—Technical Specifications SECTION 330130.16 TELEVISING AND INSPECTION OF GRAVITY SEWER SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. Work specified herein: 1. Furnish all labor, tools, test equipment and materials, including any and all permits required to televise, inspect, video tapc, still photograph and document the gravity wastewater collection systems. 1.2 QUALITY ASSURANCE A. Utilize services of competent personnel in the field of TVFvideo inspection of wastewater collection systems. B. Schedule all work with ENGINEER. C. Equipment used shall be in good working order and provide continuous operation during Plivideo tape inspection. D. VHS videotapes or DVDVideo recording media shall be of good visual quality capable of slow motion and pausing without significant reduction of visual quality. 1.3 SUBMITTALS A. Submit to the County Manager or designee a list of equipment and materials to be used on the project, including all permits obtained prior to commencing with the Work. B. Engineer of Record shall certify and Ssubmit to the County Manager or designee a copy of all television inspection log sheets and VHS videotapes or DVDvideo recording media completed. PART 2 MATERIALS 2.1 GENERAL A. Equipment used shall be designed for use in gravity wastewater collection systems. CONTRACTOR has the option of a County approved equal device or other material than that which is specified. Submittals are required prior to commencement of work. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Words stricken are deletions; words underlined are additions. Page 1 of 6 CA q 17A 2.2 TELEVISION CAMERA A. Camera used shall be 360 degrco360-deqree COLOR RVC camera. Camera shall be operative in 100% relative humidity and be specifically designed for the environment. Camera shall have an integral lighting system capable of producing clearly focused, well-defined images of the entire periphery of the pipe. Camera shall have an integral depth measurement device capable of clearly showing the depth of vertical dips. The quality of video picture and definition provided shall be to the satisfaction of the ENGINEER and, if unsatisfactory, equipment shall be removed and replaced with satisfactory equipment. 2.3 MONITOR A. A-#High resolution TV monitor scrcenvideo shall be used. Quality of fnonitec-video shall be to the satisfaction of the County Manager or designee. 2.4 VIDEO TAPE VERIFICATION EQUIPMENT A. Furnish videotape equipment to provide a visual and audio recording of all areas in the pipe. Videotape system at the site shall be capable of rewind, play back, slow motion and stop motion. The videotape shall be 1/2 inch color VHS,equipped with an audio channel for clearly recording the camera locations and operator observations (cracks, leaks, service connections, etc.). The system shall continuously indicate distance, in feet, from manhole to manhole and the manhole-to-manhole run numbers on the video recording. 2.5 WINCHES A. Furnish variable speed powered remote controlled winches for upstream and downstream manhole locations to control two-way movement of the camera. If a self-propelled camera is used, winches are not necessary. 2.6 POWER SUPPLY A. Power supply shall be continuous. If night operations occur, supply all labor, power and lighting equipment for operations, traffic safety, permits, etc. PART 3 EXECUTION 3.1 GENERAL A. All sanitary sewer gravity lines shall be televiewed televised at the CONTRACTOR's expense_; and a A videotape of the subject mains shall be provided prior to preliminary final acceptance and at the 1 y ar warranty inspection by Collier County Utilities. Televiewing may only occur after the stabilized subgrade has been installed and satisfactory density tests have been submitted to Collier County Utilities. The sewer video inspection shall include rotating the camera lens to inspect the interior of each sewer lateral. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Words stricken are deletions; words underlined are additions. Page 2 of 6 1 7 A B. Demonstrate the ability of the TV/video equipment (camera/light/video-tape/audio/ photograph system) to the satisfaction of the County Manager or designee. Distance meter shall be furnished on the video tape recording. Meter shall be checked using distances between manholes. Meter distances and actual distances shall be consistent. Depth measurement device shall be visible in the video recording during movement of the camera in the pipe. 3.2 TELEVISING/INSPECTION A. Inspection shall be done one manhole section at a time. Stop flow into the section being inspected prior to video inspection, unless otherwise approved in writing by the County Manager or designee. B. Locate video vehicle on upstream side of manhole. Video tape--in the downstream direction such that camera movement is with the flow. C. Insert the camera in the upstream manhole after flow restrictions required have been accomplished. Flow into the system being inspected shall be stopped, with the exception of service laterals into the system being inspected. Move camera through the pipe tinespipelines at a moderate speed not exceeding 30 feet per minute. Stop camera at locations where one or more of the following conditions is observed: 1. Infiltration/inflow sources. 2. Service Laterals. 3. Structural defects including broken pipe; collapsed or collapsing pipe, cracks, deterioration, punctures, etc. 4. Abnormal joint conditions such as misalignments, open joints and joints not sealed. 5. Unusual conditions such as root intrusion, protruding pipes, in-line pipe size changes, mineral deposits, grease and obstructions. D. Stop camera long enough for a thorough visual inspection of the conditions. All such conditions as specified above shall be audio recorded on videotape and the inspection log sheet. Move the camera and rotate to obtain optimum view of the conditions. If requested by the County Manager or designee, view problem areas in the opposite direction by pulling the video camera from the opposite direction at no additional cost to the COUNTY. E. While the camera is stopped at each service connection, rotate the camera so as to be able to view the service connection for a length of time that enables a good visual inspection of the service connection for damage and infiltration. Be Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 3 of 6 Words stricken are deletions; words underlined are additions. 1 7 A responsible for measurements such as service lateral locations, if used for subsequent rehabilitation work. F. When, during the inspection operation, the television camera will not pass through the entire manhole-to-manhole section, set up equipment so that the inspection can be performed from the opposite manhole at no additional cost to the COUNTY. G. Prior to final acceptance, all manholes will shall be televised and inspected. The complete interior of each manhole shall be inspected and video recorded after the interior coating has been completed. Manhole identification numbers shall be displayed on the video recording, and the recording shall accompany the submittal of the gravity lines inspection. Any deficiencies shall be corrected prior to acceptance by the County. 3.3 DOCUMENTATION A. Furnish a detailed report and videotapes of the system inspected. The minimum information supplied shall be the following: 1. Name and address of CONTRACTOR and the ENGINEER. 2. Name of OWNER, system(s) inspected, and OWNER's representative involved. 3. Log reports: a. Log sheet for each section of pipe b. Separate line for each deficiency and location c. Corresponding videotapes and location of each section of pipe and deficiencies on tapevideo. 4. Video tapes shall be labeled with the following information: a. System that is video taped recorded (street name and manhole to manhole numbers) and log report number corresponding to videotape b. Date video was tapedrecorded c. CONTRACTOR's name and representative d. OWNER's name B. All tapes videos shall be rendered unable to be taped over after they are completed. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 4of6 Words stricken are deletions; words underlined are additions. 17A 3.4 MAINTENANCE OF TRAFFIC A. Be responsible for all maintenance of traffic around work site. CONTRACTOR shall maintain traffic in accordance to all federal, state and local regulations. At no additional cost to the COUNTY, submit a Maintenance of Traffic Plan, for review and approval by Collier County DOT as necessary, prior to commencing work. Obtain all necessary permits prior to commencing work, at no additional cost to the COUNTY. B. MOT shall also include construction and maintenance of any necessary detour facilities, furnishings, installing and maintaining of traffic control and safety devices during construction, control of dust, and any other special requirements for safe and expeditious movement of traffic around or through the work site. C. Be responsible for coordination with all affected agencies when roadways will be closed or traffic will be detoured. No detours or roadway closings shall be permitted unless specifically approved in writing by the County Manager or designee or ENGINEER. END OF SECTION Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS • Page 5 of 6 Words Stricken are deletions; words underlined are additions. t'AO 1 7 A NO TEXT FOR THIS PAGE Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Words stricken are deletions; words underlined are additions. Page 6 of 6 cAO 1 7 A SECTION 330502 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances as shown on the Drawings and specified in the Contract Documents. B. High Density Polyethylene (HDPE) — Collier County Utilities has the option of approving the use of HDPE for pipeline crossings of roadways, ditches, canals, and environmentally sensitive lands. HDPE mains shall have the same equivalent internal diameter and equivalent pressure class rating as the corresponding PVC pipe, unless otherwise approved by the County Manager or designee. For all roadway crossings requiring casing pipe, a steel or DR 11 HDPE casing pipe must be provided. The Department of Transportation having jurisdiction of said road and right-of-way must grant specific approval. 1.2 REFERENCED STANDARDS A. All standard specifications, i.e., Federal, ANSI, ASTM, etc., made a portion of these Specifications by reference, shall be the latest edition and revision thereof. 1.3 QUALIFICATIONS A. Furnish all HDPE pipe, fittings, and appurtenances by a single manufacturer who is fully experienced, reputable and qualified in the manufacture of the items to be furnished. B. Installer Certification is required for the CONTRACTOR installinq thermally butt- fused HDPE pipe. 1.4 SUBMITTALS A. Submit to the ENGINEER, a list of materials to be furnished, the names of the suppliers, and the appropriate shop drawings for all HDPE pipe and fittings. B. Submit the pipe manufacturer's certification of compliance with the applicable sections of the Specifications. C. Submit shop drawings showing installation method and the proposed method and specialized equipment to be used. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 1 of 9 Words stricken are deletions; words underlined are additions. 1 7 A 1.5 INSPECTIONS AND TESTS A. All work shall be inspected by the County Manager or designee who shall have the authority to halt construction if, in his opinion, these specifications or standard construction practices are not being followed. Whenever any portion of these specifications is violated, the County Manager or designee, may order further construction to cease until all deficiencies are corrected. 1.6 WARRANTY AND ACCEPTANCE A. Warrant all work to be free from defects in workmanship and materials for a period of one year from the date of completion of all construction and final utility acceptance. If work meets these specifications, a letter of acceptance, subject to the erone-year warranty period, shall be given . A final acceptance letter shall be given upon final inspection at the end of the one year ce specifications. In the event deficiencies are discovered during the warranty period, the CONTRACTOR shall correct them without additional charge to the COUNTY before final acceptance, or the COUNTY wilimay otherwise correct them an4by drawing upon the Utilities Performance Security for reimbursement of costs. During the warranty period, the ENGINEER COUNTY will determine if warranty repairs or replacement work shall be performed by the GONTRACTORis needed. The decision of the ENGINEER COUNTY shall be binding upon the CONTRACTOROWNER. RACTOR installing thermal butt fused HDPE PART 2 PRODUCTS 2.1 POLYETHYLENE PIPE AND FITTINGS A. Provide polyethylene pressure pipe manufactured from PE3408 polyethylene meeting AWWA C906 standards. When specified by the ENGINEER on the construction drawings, as an alternate to PVC, HDPE (ductile iron pipe sized) piping can be used for buried applications. Iron pipe sized (IPS) HDPE piping can be used for below-ground applications as determined by the ENGINEER. B. The diameter of DR 11 HDPE casing pipe provided for roadway crossings or other purposes shall conform to the following. For HDPE pressure carrier pipes, casing spacers are not required when HDPE DR11 (or DR17 for 42" to 54" or DR21 for 63") casing is used. The casing inside diameter shall be a minimum of two inches larger than the carrier pipe's outside diameter. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 2 of 9 Words stricken are deletions; words underlined are additions. CAO 1 7 A HDPE to HDPE pipe C. i e connections shall be bythermal butt fusion. Thermal fusion shall be accomplished in accordance with the pipe manufacturer and fusion equipment supplier specifications. The CONTRACTOR installing thermal butt fused HDPE pipe shall be certified in this type of work and have a minimum of five years experience performing this type of work. The CONTRACTOR shall provide certification to the Engineer of Record, who will provide the Engineering Review Services Department with the certification. D. Qualification of Manufacturer: The Manufacturer shall have manufacturing and quality control facilities capable of producing and assuring the quality of the pipe and fittings required by these specifications. The Manufacturer's production facilities shall be open for inspection by the County Manager or designee. Qualified manufacturers shall be approved by the County Manager or designee. E. See the County Approved Product List, Appendix F, for manufacturers that are qualified. Products from other manufacturers proposed for the work must receive approval from the County Manager or designee prior to ordering. F. Materials: Materials used for the manufacture of polyethylene pipe and fittings shall be PE3408 high density polyethylene meeting cell classification 345434C or 345434E per ASTM D3350; and meeting Type III, Class B or Class C, Category 5, Grade P34 per ASTM D1248; and shall be listed in the name of the pipe and fitting manufacturer in PPI (Plastics Pipe Institute) TR-4, Recommended Hydrostatic Strengths and Design Stresses for Thermoplastic Pipe and Fittings Compounds, with a standard grade rating of 1600 psi at 73°F. The Manufacturer shall certify that the materials used to manufacture pipe and fittings meet these requirements. G. Polyethylene Pipe: Polyethylene pipe shall be manufactured in accordance with ASTM F714, Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter or ASTM D3035, Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter and shall be so marked. Each production lot of pipe shall be tested for (from material or pipe) melt index, density, % carbon, (from pipe) dimensions and either quick burst or ring tensile strength (equipment permitting). H. Color Identification: HDPE must have at least three equally spaced horizontal colored marking stripes. Permanent identification of piping service shall be provided by adhering to the following colors. Blue — potable water (Underground HDPE pipe shall be one of the following: a. Solid-wall blue pipe; b. Co-extruded blue external skin; or Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HOPE) PIPE AND FITTINGS Page 3 of 9 Words stricken are deletions; words underlined are additions. S A c. White or black pipe with blue stripes incorporated into, or applied to, the pipe wall. White — raw water Green —wastewater, sewage Pantone Purple — non-potable irrigation, reclaimed or reuse water Polyethylene Fittings and Custom Fabrications: Polyethylene fittings and custom fabrications shall be molded or fabricated by the pipe manufacturer. Butt fusion outlets shall be made to the same outside diameter, wall thickness, and tolerances as the mating pipe. All fittings and custom fabrications shall be fully rated for the same internal pressure as the mating pipe. Pressure de-rated fabricated fittings are prohibited. J. Molded Fittings: Molded fittings shall be manufactured in accordance with ASTM D3261, Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing, and shall be so marked. Each production lot of molded fittings shall be subjected to the tests required under ASTM D3261. K. X-Ray Inspection: The Manufacturer shall submit samples from each molded fittings production lot to x-ray inspection for voids; and shall certify that voids were not found. L. Fabricated Fittings: Fabricated fittings shall be made by heat fusion joining specially machined shapes cut from pipe, polyethylene sheet stock, or molded fittings. Fabricated fittings shall be rated for internal pressure service equivalent to the full service pressure rating of the mating pipe. Directional fittings 16" IPS and larger such as elbows, tees, crosses, etc., shall have a plain end inlet for butt fusion and flanged directional outlets. Part drawings shall be submitted for the approval of the ENGINEER. M. Polyethylene Flange Adapters: Flange adapters shall be made with sufficient through-bore length to be clamped in a butt fusion joining machine without the use of a stub-end holder. The sealing surface of the flange adapter shall be machined with a series of small v-shaped grooves to provide gasketless sealing, or to restrain the gasket against blow-out. N. Back-up Rings and Flange Bolts: Flange adapters shall be fitted with lap joint flanges pressure rated equal to or greater than the mating pipe. The lap joint flange bore shall be chamfered or radiused to provide clearance to the flange adapter radius. Flange bolts and nuts shall be Grade 2 or higher. 2.2 MANUFACTURER'S QUALITY CONTROL A. The pipe and fitting manufacturer shall have an established quality control program responsible for inspecting incoming and outgoing materials. Incoming polyethylene materials shall be inspected for density, melt flow rate, and Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 4 of 9 Words Stricken are deletions; words underlined are additions. 17A contamination. The cell classification properties of the material shall be certified by the supplier; and verified by Manufacturer's Quality Control. Incoming materials shall be approved by Quality Control before processing into finished goods. Outgoing materials shall be checked for: 1. Outside diameter, wall thickness, and eccentricity as per ASTM D2122 at a frequency of at least once/hour or once/coil, whichever is less frequent. 2. Out of Roundness at frequency of at least once/hour or once/coil, whichever is less frequent. 3. Straightness, inside and outside surface finish, markings and end cuts shall be visually inspected as per ASTM F714 on every length of pipe. B. Quality Control shall verify production checks and test for: 1. Density as per ASTM D1505 at a frequency of at least once per extrusion lot. 2. Melt Index as per ASTM D1238 at a frequency of at least once per extrusion lot. 3. Carbon content as per ASTM D1603 at a frequency of at least once per day per extrusion line. 4. Quick burst pressure (sizes thru 4-inch) as per ASTM D1599 at a frequency of at least once per day per line. 5. Ring Tensile Strength (sizes above 4-inch equipment permitting) as per ASTM D2290 at a frequency of at least once per day per line. 6. ESCR (size permitting) as per ASTM F1248 at a frequency of at least once per extrusion lot. C. X-ray inspection shall be used to inspect molded fittings for voids, and knit line strength shall be tested. All fabricated fittings shall be inspected for joint quality and alignment. 2.3 COMPLIANCE TESTS A. In case of conflict with Manufacturer's certifications, the CONTRACTOR, ENGINEER, or County Manager or designee may request re-testing by the manufacturer or have re-tests performed by an outside testing service. All re- testing shall be at the requestor's expense; and shall be performed in accordance with the Specifications. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 5 of 9 Words stricken are deletions; words underlined are additions. S 1 7 A B. Installation shall be in accordance with Manufacturer's recommendations and this specification. All necessary precautions shall be taken to ensure a safe working environment in accordance with the applicable codes and standards. PART 3 EXECUTION 3.1 INSTALLATION OF HIGH HIGH-DENSITY POLYETHYLENE PRESSURE PIPE AND FITTINGS A. Install all high high-density polyethylene (HDPE) pressure pipe by direct bury, directional bore, or a method approved by the COUNTY or ENGINEER prior to construction. If directional bore is used, or if directed by the County Manager or designee or ENGINEER, surround the entire area of construction by silt barriers. Install all high high-density polyethylene pressure pipe and fittings in accordance with Manufacturer's recommendations, and this specification. Take all necessary precautions to ensure a safe working environment in accordance with the applicable codes and standards. 3.2 HEAT FUSION JOINING A. Make joints between plain end pipes and fittings by butt fusion, and joints between the main and saddle branch fittings by using saddle fusion using only procedures that are recommended by the pipe and fitting Manufacturer. Ensure that persons making heat fusion joints have received training and certification for heat fusion in the Manufacturer's recommended procedure. Maintain records of trained personnel, and shall certify that training was received not more than 12 months before commencing construction. External and internal beads shall not be removed. 3.3 MECHANICAL JOINING A. HDPE pipe and fittings shall be fused together by heat welding when possible. HDPE pipe and fittings may be joined together or to other materials by means of flanged connections with back-up rings, by mechanical joint adapter with glands, or mechanical couplings designed for joining HDPE pipe or for joining HDPE pipe to another material. A stainlesc stainless-steel sleeve insert shall be used with a mechanical coupling. Mechanical couplings shall be fully pressure rated and fully thrust restrained such that when installed in accordance with manufacturer's recommendations, a longitudinal load applied to the mechanical coupling will cause the pipe to yield before the mechanical coupling disjoins. 3.4 BRANCH CONNECTIONS A. Make branch connections to the main with saddle fittings or tees. Saddle fuse polyethylene saddle fittings to the main pipe. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 6 of 9 Words strieken are deletions; words underlined are additions. 1 7 A 3.5 EXCAVATION A. Excavate trenches in conformance to this specification, the plans and drawings, or as authorized in writing by the County Manager or designee, and in accordance with all applicable codes. Remove excess groundwater. Where necessary, shore or reinforce trench walls. 3.6 LARGE DIAMETER FABRICATED FITTINGS A. Butt fuse fabricated directional fittings 16" IPS and larger to the end of a pipe. Make up the flanged directional outlet connections in the trench. 3.7 MECHANCIAL JOINT AND FLANGE INSTALLATION A. Install mechanical joints and flange connections in accordance with the Manufacturer's recommended procedure. Center and align flange faces to each other before assembling and tightening bolts. Do not use the flange bolts to draw the flanges into alignment. Lubricate bolt threads, and fit flat washers under the flange nuts. Tighten bolts evenly according to the tightening pattern and torque step recommendations of the Manufacturer. At least one hour after initial assembly, re-tighten flange connections following the tightening pattern and torque step recommendations of the Manufacturer. The final tightening torque shall be 100 ft-lbs or less as recommended by the Manufacturer. 3.8 FOUNDATION AND BEDDING A. Lay pipe on grade and on a stable foundation. Remove unstable or mucky trench bottom soils, and install a 6-inch foundation or bedding of compacted Class I material to pipe bottom grade. Remove excess groundwater from the trench before laying the foundation or bedding and the pipe. A trench cut in rock or stony soil shall be excavated to 6 inches below pipe bottom grade- and brought back to grade with compacted Class I bedding. Remove all ledge rock, boulders, and large stones. 3.9 PIPE HANDLING A. When lifting with slings, use only wide fabric choker slings to lift, move, or lower pipe and fittings. Do not use wire rope or chain. Slings shall be of sufficient capacity for the load; and shall be inspected before use. Do not use worn or defective equipment. 3.10 TESTING A. Hydrostatic Pressure Testing: Pressure test and flush HDPE pipes after swabbing in accordance with Section 022501 and 025400. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 7 of 9 Words stricken are deletions; words underlined are additions. C't o 1 7 A END OF SECTION Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 8 of 9 Words stricken are deletions; words underlined are additions. C'Ao I 7A NO TEXT FOR THIS PAGE Section 330502 C-A0i COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 9 of 9 Words stricken are deletions; words underlined are additions. 17A Section 4—Appendices,Appendix D: Utilities Conveyance Checklist Utilities Conveyance Checklist POTABLE WATER, NON-POTABLE IRRIGATION WATER AND WASTEWATER FACILITIES ACCEPTANCE Today's Date: Project Name: Original Utility Project No. PL#: (AR/PL): Submittal Requirements N/A review i accepttem ed Item Needed Notes 11. ❑ ❑ ❑ Final Utility Conveyance Acceptance-Application 2. ❑ ❑ ❑ Addressing Checklist(ID number or Folio number of Property) Legal Documents ' Item " N/A review accepted cept Item Needed Notes 1. ❑ ❑ ❑ Attorney's Affidavit 2. 0 ❑ 0 Owner's Affidavit 3. 0 0 0 Warranty Deed/Bill of Sale with Exhibit B per Utilities Standards and Procedures Ordinance Section 134-60(b)(4), Code of Laws and Ordinances1-?6 4. 0 0 0 Utilities Facilities Securities Subordination (required when any security interest in the utility facilities/systems is involved). UCC-1(s)can be subordinated by a Subordination or by use of UCC-3(s)if not released by Subordination. 5. ❑ ❑ 0 Deed of Utility Easement- Copy of last Deed that conveyed title of the Associated Real Property and Copy of all Utility Easements then being conveyed to the County, including legal description with Surveyor's Sketch of Easement. (Utility easements are not required provided all utility facilities then being conveyed are in public right-of way, are in then existing utility easements,or are in CUEs) . ❑ 0 0 Utilities Performance Security (UPS) per Utilities Standards and Procedures Ordinance Section 134-58(e), Code of Laws and Ordinances1-024-0f-TOtai-Cost- ginal-Obligations-sasil-be-nd-ef-- R-6939-&-alaeve) 7. ❑ 0 ❑ Final Release of Lien from Utility Contractor for the system(s) or portion(s) thereof constructed Page 1 of 3 i Rev.7428482/2021 Words stricken are deletions; words underlined are additions. it CHECKLIST I I 4 WATER&SEWER FACILITIES ACCEPTANCE COUNTY ORDINANCE 97-17,AS AMENDED Page 2 ❑ ❑ ❑ {� . Q U ❑ Final Attorney's Affidavit (provide upon recording legal documents) ests, Certifications and Supplemental Documents N/A In Item Notes review accepted Item Needed 1. ❑ ❑ ❑ Sewer Video of constructed gravity sewer(Sewer Report & Master Utility Sheet) 2. ❑ ❑ ❑ Certification of pressure testing of wastewater force mains by Engineer of Record 3. ❑ ❑ ❑ Certification of the infiltration/exfiltration tests for the sewer lines by Engineer of Record 4. ❑ ❑ ❑ Coating certification from the manufacturer or a professional testing laboratory for all manholes, wet wells and valve vault. 5. ❑ ❑ ❑ Lift station(s) start up report(s) 6. ❑ ❑ ❑ Electrical Contractor's certification of Lift Station electric service wire sizing and voltage drop pursuant to National Electrical Code Specifications 7. ❑ ❑ ❑ Start-up and successful testing of Data Flow telemetry equipment (AR-7936&above) 8. ❑ ❑ ❑ Certification of pressure testing of water and non-potable irrigation mains by Engineer of Record 9. ❑ ❑ ❑ Letter by Engineer certifying that: • All water, non-potable irrigation and/or sewer facilities are located within the public right-of-way or dedicated easements • All the utilities system(s), or portion(s) thereof, has been constructed in accordance with County Ordinances and Regulations, including the required color for piping 10. ❑ ❑ ❑ One year(1) Warranty on work performed and system(s) or portion(s) thereof installed by Utilities Contractor 11. ❑ ❑ ❑ Engineer's Final Payment Confirmation 11 2. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for WATER facilities (including interim facilities, if applicable); 13. ❑ ❑ ❑ DEP WATER Certification approval to be forwarded when received Page 2 of 3 Words stricken are deletions; words underlined are additions. Rev.07i20182i2021 (Ao CHECKLIST 7 A WATER &SEWER FACILITIES ACCEPTANCE COUNTY ORDINANCE 97-17,AS AMENDED Page 3 14. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for SEWER facilities (including interim facilities, if applicable); 15. ❑ ❑ ❑ DEP SEWER Certification approval to be forwarded when received 16. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for(RECLAIMED) NON-POTABLE IRRIGATION WATER facilities (including interim facilities, if applicable); In-service Letter to be forwarded when received 17. ❑ ❑ ❑ Lab results on bacteriological tests for potable water mains 18. ❑ ❑ ❑ Satisfactory Test Reports and Certification of backflow device by Certified Laboratory. 19. ❑ ❑ ❑ Verification of Final Cost(Include materials and labor, misc.) Cost breakdown —Contributory Assets for County/Private Materials (materials only) (i.e.detailed quantities,sizes, unit cost,total cost,etc) 20 ❑ 0 ❑ Letter from the Fire District regarding ownership and maintenance of fire hydrants 21. ❑ ❑ ❑ Signed copy of field fire flow testing by the applicable Fire Control District Engineering Documents N/A In Item review accepted Item Needed Notes 1. ❑ ❑ ❑ One (1) complete set of Record Drawings to include all utilities and all related underground work signed and sealed by the Engineer of Record for potable water, non-potable irrigation water and / or wastewater system(s) or portion(s) thereof 2. ❑ ❑ ❑ One (1) computer-generated disk of Record Drawings in CAD and PDF format per Utilities Standards and Procedures Ordinance Section 134-58(e), Code of Laws and Ordinances 3. ❑ LI ❑ Longitude and latitude shall appear on detail sheet. (AR-7936&above) Office Use Only below this line Ow Owls Os ❑IRR Page 3 of 3 Rev.07/20182/2021 Words stricken are deletions; words underlined are additions. 1 ? A Acct #324207 June 22, 2021 Attn: Legals Naples News Media Group 1100 Immokalee Road Naples, Florida 34110 Re: Resolution - Amendments to Utilities Standards Manual Dear Legals: Please advertise the above referenced notice (in the Classified Section of the paper) on Wednesday, June 30, 2021 and kindly send the Affidavit of Publication, together with charges involved, to this office. Thank you. Sincerely, Martha Vergara, Deputy Clerk P.O. #4500211329 1 7 A NOTICE OF HEARING Notice is hereby given that a public hearing will be held by the Collier County Board of County Commissioners on June 22,2021, in the Board of County Commissioners Meeting Room, Third Floor,Collier Government Center, 3299 Tamiami Trail East,Naples FL.,the Board of County Commissioners(BCC)will consider the enactment of a County Resolution. The meeting will commence at 9:00 A.M. The title of the proposed Resolution is as follows: A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA,AS THE GOVERNING BODY OF COLLIER COUNTY,FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT,APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DISTRICT'S UTILITIES STANDARDS MANUAL,WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31,AS AMENDED,KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE,WHICH IS CODIFIED IN CHAPTER 134,ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COINCIDE WITH THE COMPANION AMENDING ORDINANCE. A copy of the proposed Resolution is on file with the Clerk to the Board and is available for inspection. All interested parties are invited to attend and be heard. NOTE:All persons wishing to speak on any agenda item must register with the County manager prior to presentation of the agenda item to be addressed. Individual speakers will be limited to 3 minutes on any item. The selection of any individual to speak on behalf of an organization or group is encouraged. If recognized by the Chairman, a spokesperson for a group or organization may be allotted 10 minutes to speak on an item. Persons wishing to have written or graphic materials included in the Board agenda packets must submit said material a minimum of 3 weeks prior to the respective public hearing. In any case, written materials intended to be considered by the Board shall be submitted to the appropriate County staff a minimum of seven days prior to the public hearing. All materials used in presentations before the Board will become a permanent part of the record. As part of an ongoing initiative to promote social distancing during the COVID-19 pandemic,the public will have the opportunity to provide public comments remotely,as well as in person, during this proceeding. Individuals who would like to participate remotely, should register up to 6 days in advance through the link provided on the front page of the county website at www.colliercountyfl.gov. Individuals who register will receive an email in advance of the public hearing detailing how they can participate remotely in this meeting. Any person who decides to appeal any decision of the Board will need a record of the proceedings pertaining thereto and therefore, may need to ensure that a verbatim record of the proceedings is made,which record includes the testimony and evidence upon which the appeal is based. If you are a person with a disability who needs any accommodation in order to participate in this proceeding,you are entitled, at no cost to you,to the provision of certain assistance. Please contact the Collier County Facilities Management Division, located at 3335 Tamiami Trail East, Suite 101,Naples, FL 34112-5356, (239)252-8380, at least two days prior to the meeting. Assisted listening devices for the hearing impaired are available in the Board of County Commissioners Office. BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA PENNY TAYLOR., CHAIRMAN CRYSTAL K. KINZEL, CLERK By: Martha Vergara, Deputy Clerk(SEAL) 1 7 A Martha S. Vergara From: Gannett Legals Public Notices 4 <ganlegpubnotices4@gannett.com> Sent: Tuesday, June 22, 2021 3:34 PM To: Martha S. Vergara Subject: RE:4793624 Resolution - Amendment to the Utilities Standards & Procedures Manual Attachments: OrderConf.pdf External Message: Please use caution when opening attachments, clicking links, or replying to this message. Hello, Your notice is scheduled to publish Jun 30 in the Desert Sun. The total cost of your notice is $539, which includes a publisher affidavit that will be mailed to you after the last date of publication. Thank you, `lath or,',i\;',;'b r Pubic Nc e <:i> er1taI:vc VIVO '` L.O+CALIQ Office:844-254-5287 From: Martha S. Vergara <Martha.Vergara@collierclerk.com> Sent:Tuesday,June 22, 2021 2:19 PM To: NDN-Legals<legals@naplesnews.com> Subject:4793624 Resolution -Amendment to the Utilities Standards& Procedures Manual Hello, Please advertise the following attached on Wednesday,June 30, 2021. (Please place this ad were legal notices are placed.) Please forward an ok when received, if you have any questions feel free to call. Thanks, 1 1 7 A I PART OF THE USA TODAY NETWORK BCC COMPREHENSIVE PL 3299 TAMIAMI TRL E 700 NAPLES FL 34112- Account AD# Net Amount Tax Amount Total Amount Payment Method Payment Amount Amount Due 1303804 0004793624 $539.00 $0.00 $539.00 Invoice $0.00 $539.00 Sales Rep: mweber Order Taker: mweber Order Created 06/22/2021 Product #Ins Column Agate Lines Start Date End Date NDN-Naples Daily News 1 2.00 154 06/30/2021 06/30/2021 NDN-naplesnews.com 1 2.00 154 06/30/2021 06/30/2021 ALL TRANSACTIONS CONSIDERED PAID IN FULL UPON CLEARANCE OF FINANCIAL INSTITUTION Text of Ad: 06/22/2021 1 7 A NOTICE OF HEARING Notice is hereby given that a public hearing will be held by the Collier CountyBoard of County Commissioners on June 22,2021, in the Board of County Commissioners Meeting Room, Third Floor, Collier Government Center, 3299 Tamiami Trail East, Na- ples FL., the Board of County Commissioners (BCC) will consider the enactment of a County Resolution. The meeting will com- mence at 9:00 A.M. The title of the proposed Resolution is as follows: A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COL- LIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DIS- TRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTE- GRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STAND- ARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDI- NANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COIN- CIDE WITH THE COMPANION AMENDING ORDINANCE. A copy of the proposed Resolution is on file with the Clerk to the Board and is available for inspection. All interested parties are invited to attend and be heard. NOTE: All persons wishing to speak on any agenda item must register with the County manager prior to presentation of the agenda item to be addressed. Individual speakers will be limit- ed to 3 minutes on any item. The selection of any individual to speak on behalf of an organization or group is encouraged. If recognized by the Chairman, a spokesperson for a group or or- ganization may be allotted 10 minutes to speak on an item. Persons wishing to have written or graphic materials included in the Board agenda packets must submit said material a minimum of 3 weeks prior to the respective public hearing. In any case, written materials intended to be considered by the Board shall be submitted to the appropriate County staff a minimum of seven days prior to the public hearing. All materials used in pre- sentations before the Board will become a permanent part of the record. As part of an ongoing initiative to promote social distancing during the COVID-19 pandemic, the public will have the oppor- tunity to provide public comments remotely, as well as in per- son, during this proceeding. Individuals who would like to par- ticipate remotely, should register up to 6 days in advance through the link provided on the front page of the county website at www.colliercountyfl.gov. Individuals who register will receive an email in advance of the public hearing detailing how they can participate remotely in this meeting. Any person who decides to appeal any decision of the Board will need a record of the proceedings pertaining thereto and therefore, may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is based. If you are a person with a disability who needs any accommoda- tion in order to participate in this proceeding, you are entitled, at no cost to you, to the provision of certain assistance. Please contact the Collier County Facilities Management Division, locat- ed at 3335 Tamiami Trail East, Suite 101, Naples, FL 34112-5356, (239) 252-8380, at least two days prior to the meeting. Assisted listening devices for the hearing impaired are available in the Board of County Commissioners Office. BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY,FLORIDA PENNY TAYLOR.,CHAIRMAN CRYSTAL K.KINZEL,CLERK By: Martha Vergara,Deputy Clerk(SEAL) Pub Dates:June 30,2021 #4793624 Martha S. Vergara f A From: Gannett Legals Public Notices 4 <ganlegpubnotices4@gannett.com> Sent: Tuesday, June 22, 2021 3:19 PM To: Martha S. Vergara Subject: DO NOT REPLY External Message: Please use caution when opening attachments, clicking links, or replying to this message. This is an auto generated email, please do not reply. Please note the Legal Dept will be closed July 5th for the Holiday. Early deadlines will be in effect ask for details to avoid any delays in processing and publishing. The legal department has received your email and will be processing your notice as soon as possible. We will provide a proof as well as publication dates, cost and payment requirements prior to the notice running. All Legal/Public Notices will be processed for the desired publication if received by deadline. Office Hours: Monday— Friday 8:00 am -5:00 pm CST/EST Thank you for your business. Gannett Legal/Public Notice Department 17A Martha S. Vergara From: Martha S. Vergara Sent: Wednesday, June 23, 2021 8:08 AM To: RodriguezWanda; ChmelikTom; 'raineyjennifera@colliercountyfl.gov'; 'PerryDerek' Subject: Resolution - Amendment to Utilities Standards Manual Attachments: OrderConf.pdf Morning All, Attached is the above referenced ad request. Please let me know of any changes needed. Thanks, Martha Vergara BMR &VAB Senior Deputy Clerk Office: 239-252-7240 `'%. Fax: 239-252-8408 E-mail: martha.vergara@CoilierClerk.com Office of the Clerk of the Circuit Court & Comptroller of Collier County , ti " 3299 Tamiami Trail E, Suite #401 Naples, FL 34112 www.CollierClerk.com i Martha S. Vergara 1 7 A From: ChmelikTom <Tom.Chmelik@colliercountyfl.gov> Sent: Wednesday, June 23, 2021 9:06 AM To: RodriguezWanda Cc: PerryDerek; FeyEric; RaineyJenniferA Subject: • Utilities Ordinance and Manual ads Attachments: ad proof: Resolution - Amendment to Utilities Standards Manual; ad proof: Ord. Amending Ord. 2004-31 Utilities Standards & Procedures Ord. Wanda, Both ads are approved as requested in your two attached emails. Thank you for your prompt assistance. Respectfully, Tom Chmelik Division Director Co r County Public Utilities Department Engineering& Project Management Division Motto: "Continuous Improvement" 3339 Tamiami Trail East, Suite 303, Naples, FL 34112-5361 Phone: 239-252-6213 Cell: 239-438-0824 www.colliercountyfl.gov "HOW ARE WE DOING?" Please click here for our Customer Service Survey Under Florida Law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. 1 11A Martha S. Vergara From: PerryDerek <Derek.Perry@colliercountyfl.gov> Sent: Thursday, June 24, 2021 9:08 AM To: RodriguezWanda Cc: CrotteauKathynell Subject: RE: proof for approval: Resolution - Amendment to Utilities Standards Manual Wanda: This item is approved. Thank you, Derek D. Perry Assistant County Attorney (239) 252-8066 From: RodriguezWanda <Wanda.Rodriguez@colliercountyfl.gov> Sent:Thursday,June 24, 2021 8:58 AM To: PerryDerek<Derek.Perry@colliercountyfl.gov> Cc: CrotteauKathynell <Kathynell.Crotteau@colliercountyfl.gov> Subject: FW: proof for approval: Resolution -Amendment to Utilities Standards Manual Derek, Have you had a chance to look at this yet? From: RodriguezWanda Sent: Wednesday, June 23, 2021 8:20 AM To: PerryDerek<Derek.Perry@colliercountyfl.gov> Subject: proof for approval: Resolution -Amendment to Utilities Standards Manual Derek, For your approval. Wanda Rodriguez, MCP, CPM Office of the County .Attorney (239) 252-8400 From: Martha S. Vergara <Martha.Vergara@collierclerk.com> Sent: Wednesday,June 23, 2021 8:08 AM To: RodriguezWanda <Wanda.Rodriguez@colliercountyfl.gov>; ChmelikTom <Tom.Chmelik@colliercountyfl.gov>; 'raineyjennifera@colliercountyfl.gov' <raineyiennifera@colliercountyfl.gov>; PerryDerek <Derek.Perry@colliercountyfl.gov> Subject: Resolution -Amendment to Utilities Standards Manual i Martha S. Vergara 1 7 A From: RodriguezWanda <Wanda.Rodriguez@colliercountyfl.gov> Sent: Thursday,June 24, 2021 9:29 AM To: Minutes and Records; Martha S. Vergara Cc: ChmelikTom; RaineyJenniferA Subject: proof approval: Resolution -Amendment to Utilities Standards Manual Attachments: OrderConf.pdf; Utilities Ordinance and Manual ads; RE: proof for approval: Resolution - Amendment to Utilities Standards Manual Martha, Staff and CAO approvals are attached. Thank you, Wanda Rodriguez, ACT, CP.t4 Office of the County .attorney (239) 252-8400 From: Martha S. Vergara <Martha.Vergara@collierclerk.com> Sent: Wednesday,June 23, 2021 8:08 AM To: RodriguezWanda <Wanda.Rodriguez@colliercountyfl.gov>; ChmelikTom <Tom.Chmelik@colliercountyfl.gov>; 'raineyjennifera@colliercountyfl.gov' <raineyjennifera@colliercountyfl.gov>; PerryDerek <Derek.Perry@colliercountyfl.gov> Subject: Resolution -Amendment to Utilities Standards Manual This email is from an external source. Confirm this is a trusted sender and use extreme caution when opening attachments or clicking links. Morning All, Attached is the above referenced ad request. Please let me know of any changes needed. Thanks, 1 17A Martha S. Vergara From: Martha S. Vergara Sent: Thursday,June 24, 2021 9:45 AM To: 'Gannett Legals Public Notices 4' Subject: RE:4793624 Resolution -Amendment to the Utilities Standards & Procedures Manual Hi Madison, This ad proof has been reviewed and approved by the legal department. Please proceed with publishing as requested. Thanks, Martha From: Gannett Legals Public Notices 4<ganlegpubnotices4@gannett.com> Sent: Tuesday,June 22, 2021 3:34 PM To: Martha S. Vergara <Martha.Vergara@collierclerk.com> Subject: RE: 4793624 Resolution -Amendment to the Utilities Standards & Procedures Manual E x =rr, 41 1414>, <a, rx: Please use caution when opening attachments,clicking links, or replying to this message. Hello, Your notice is scheduled to publish Jun 30 in the Desert Sun. The total cost of your notice is $539, which includes a publisher affidavit that will be mailed to you after the last date of publication. Thank you, USA ORK L/' /+/�LI NCTWQit1{ ''VV�\rrM 844-254-5287 From: Martha S. Vergara <Martha.Vergara@collierclerk.com> Sent:Tuesday,June 22, 2021 2:19 PM To: NDN-Legals<legals@naplesnews.com> Subject: 4793624 Resolution -Amendment to the Utilities Standards & Procedures Manual 1 (!(42 1) 1 7 A 1OD I WEDNESDAY, JUNE 30,2021 I NAPLES DAILY NEWS Public Notices NOTICE OF HEARING Notice is hereby given that a public hearing will be held by the Collier County Board of County Commissioners on June 22,2021, in the Board of County Commissioners Meeting Room, Third Floor, Collier Government Center, 3299 Tamiami Trail East, Na- ples FL., the Board of County Commissioners (BCC) will consider the enactment of a County Resolution. The meeting will com- mence at 9_00 A.M. The title of the proposed Resolution is as follows: A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COL- LIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DIS- TRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTE- GRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STAND- ARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDI- NANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COIN- CIDE WITH THE COMPANION AMENDING ORDINANCE. A copy of the proposed Resolution is on file with the Clerk to the Board and is available for inspection. All interested parties are invited to attend and be heard. NOTE: All persons wishing to speak on any agenda item must register with the County manager prior to presentation of the agenda item to be addressed. Individual speakers will be limit- ed to 3 minutes on any item. The selection of any individual to speak on behalf of an organization or group is encouraged. If recognized by the Chairman, a spokesperson for a group or or- ganization may be allotted 10 minutes to speak on an item. Persons wishing to have written or graphic materials included in the Board agenda packets must submit said material a minimum of 3 weeks prior to the respective public hearing. In any case, written materials intended to be considered by the Board shall be submitted to the appropriate County staff a minimum of seven days prior to the public hearing. All materials used in pre- sentations before the Board will become a permanent part of the record. As part of an ongoing initiative to promote social distancing during the COVID-19 pandemic, the public will have the oppor- tunity to provide public comments remotely, as well as in per- son, during this proceeding. Individuals who would like to par- ticipate remotely, should register up to 6 days in advance through the link provided on the front page of the county website at www.colliercountyfl.gov. Individuals who register will receive an email in advance of the public hearing detailing how they can participate remotely in this meeting. Any person who decides to appeal any decision of the Board will need a record of the proceedings pertaining thereto and therefore, may need to ensure that a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is based. If you are a person with a disability who needs any accommoda- tion in order to participate in this proceeding, you are entitled, at no cost to you, to the provision of certain assistance. Please contact the Collier County Facilities Management Division, locat- ed at 3335 Tamiami Trail East, Suite 101, Naples, FL 34112-5356, 4 (239) 252-8380, at least two days prior to the meeting. Assisted listening devices for the hearing impaired are available in the Board of County Commissioners Office. BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY,FLORIDA PENNY TAYLOR.,CHAIRMAN CRYSTAL K.KINZEL,CLERK By: Martha Vergara,Deputy Clerk(SEAL) Pub Dates:June 30,2021 #4793624 4.1 1 ? A S. Batt ,atitt . PART OF THE USA TODAY NETWORK Published Daily Naples, FL 34110 BCC COMPREHENSIVE PL ANNING DEV 3299 TAMIAMI TRL_ E 700 NOTICE OF HEARING NAPLES, FL 34112 Notice is hereby given that a public hearing will be held by the Collier County Board of County Commissioners on June 22,2021, in the Board of County Commissioners Meeting Room, Third Affidavit of Publication Floor, Collier Government Center, 3299 Tamiami Trail East,STATE OF WISCONSIN Na- ples FL, the Board of County Commissioners (BCC)will consider the enactment of a County Resolution. The meeting will corn- COUNTY OF BROWN mence at 9:00 A.M. The title of the proposed Resolution is as follows: Before the undersigned they serve as the authority, A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA,AS THE GOVERNING BODY OF COL- personally appeared said legal clerk who on oath says that LIER COUNTY,FLORIDA AND EX-OFFICIO GOVERNING BOARD OF he/she :serves as Legal Clerk of the Naples Daily News, a THE COLLIER COUNTY WATER-SEWER DISTRICT, APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DIS- daily newspaper published at Naples, in Collier County, TRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTE- Florida• distributed in Collier and Lee counties of Florida; GRAL PART OF COLLIER COUNTY ORDINANCE NO, 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STAND- that the attached copy of the advertising was published in ARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN Said newspaper on dates listed. Affiant further says that the CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDI- NANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COIN- said Naples Daily News is a newspaper published at CIDE WITH THE COMPANION AMENDING ORDINANCE. Naples, in said Collier County, Florida, and that the said A copy of the proposed Resolution is on file with the Clerk to newspaper has heretofore been continuously published in the Board and is available for inspection. All interested parties said are invited to attend and be heard. Collier County, Florida: distributed in Collier and Lee NOTE: All persons wishing to speak on any agenda item roust counties of Florida, each day and has been entered as register with the County manager prior to presentation of the agenda Item to be addressed. Individual speakers will be limit- second class mail matter at the post office in Naples, in ed to 3 minutes on any item. The selection of any individual to said Collier County, Florida, for a period of one year next speak on behalf of an organization or group is encouraged: If recognized by the Chairman, a spokesperson for a group or or• preceding the first publication of the attached copy of ganization may allotted 10 minutes to speak on an item. advertisement; and uffi,n; further says that he has neither Persons wishing to have written or graphic materials included in paid nor proini,ec1 any person. or corporation any discount, the Board agenda packets must submit said material a minimum rebate, commission or refund for the purpose of securing of 3 weeks prior to the respective public hearing. Jn any case, written materials intended to be considered by the Board shall this advertisement for publication in the said newspaper. be submitted to the appropriate County staff a minimum of seven days prior to the public hearing.All materials used in pre- sentations before the Board will become a permanent part of Published:06/30/2021 the record. As part: of an ongoing initiative to promote social distancing during the COVID-19 pandemic, the public will have the oppor- tunity to provide public comments remotely, as well as in per- son, during this proceeding. Individuals who would like to par- Subscribed and sworn to before on June 30, 2021. ticipate remotely, should register up to 6 days in advance through the link provided on the front page of the county website at www,colliercountyfl.gov. Individuals who register will receive an email in advance of the public hearing detailing how they can participate remotely in this meeting. Any person who decides to appeal any decision of the Board Notary, State of Wi,County of Brown will need a record of the proceedings pertaining thereto and therefore, may need to ensure that a verbatim record of the �.._ proceedings is made, which record includes the testimony and evidence upon which the appeal is based. If you are a person with a disability who needs any accommoda- s'. r;s i r• tion in order to participate in this proceeding, you are entitled, at no cost to you, to the provision of certain assistance, Please contact the Collier County Facilities Management Division, locat- ed at 3335 Tamiami Trail East,Suite 101,Naples,FL 34112-5356, (239)252-8380, at least two days prior to the meeting. Assisted My commission expires August 6, 2021 listening devices for the hearing impaired are available in the Board of County Commissioners Office. BOARD OF COUNTY COMMISSIONERS Publication Cost: $539.00 COLLIER COUNTY,FLORIDA PENNY TAYLOR.,CHAIRMAN Ad No: 0004793674 Customer No: 1303804 CRYSTAL K.KINZEL,CLERK PO#: Commissioners Pub Martha Vergara,Deputy Clerk(SEAL) Pub Dates:June 30,2021 44793624 #of Affidavits) This is not an invoice ORIGINAL DOCUMENTS CHECKLIST & ROUTING SLIP 1 7 A TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT TO THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGNATURE Print on pink paper. Attach to original document. The completed routing slip and original documents are to be forwarded to the County Attorney Office at the time the item is placed on the agenda. All completed routing slips and original documents must be received in the County Attorney Office no later than Monday preceding the Board meeting. **NEW** ROUTING SLIP Complete routing lines#1 through#2 as appropriate for additional signatures,dates,and/or information needed. If the document is already complete with the exception of the Chairman's signature,draw a line through routing lines#1 through#2,complete the checklist,and forward to the County Attorney Office. Route to Addressee s (List in routing order) Office Initials Date 3 County Attorney Office County Attorney Office Db e 0112-k 4. BCC Office Board of County c b Commissioners ) 7/1-691 5. Minutes and Records Clerk of Court's Office ter+ 1C1}2 r (,,011VL- PRIMARY CONTACT INFORMATION Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the addressees above,may need to contact staff for additional or missing information. Name of Primary Staff Eric Fey/Public Utilities Engineering& Phone Number 252-1037 Contact/ Department Project Management Division Agenda Date Item was 7/13/2021 Agenda Item Number 17A Approved by the BCC Type of Document Resolution ^ ' �� Number of Original 1 Attached o,L 1 Documents Attached PO number or account number if document is to be recorded INSTRUCTIONS & CHECKLIST Initial the Yes column or mark"N/A"in the Not Applicable column,whichever is Yes N/A(Not appropriate. (Initial) Applicable) 1. Does the document require the chairman's original signature? 2. Does the document need to be sent to another agency for additional signatures? If yes, N/A provide the Contact Information(Name;Agency;Address;Phone)on an attached sheet. 3. Original document has been signed/initialed for legal sufficiency. (All documents to be EF signed by the Chairman,with the exception of most letters,must be reviewed and signed by the Office of the County Attorney. 4. All handwritten strike-through and revisions have been initialed by the County Attorney's N/A Office and all other parties except the BCC Chairman and the Clerk to the Board 5. The Chairman's signature line date has been entered as the date of BCC approval of the EF document or the final negotiated contract date whichever is applicable. 6. "Sign here"tabs are placed on the appropriate pages indicating where the Chairman's signature and initials are required. 7. In most cases(some contracts are an exception),the original document and this routing slip N/A should be provided to the County Attorney Office at the time the item is input into SIRE. Some documents are time sensitive and require forwarding to Tallahassee within a certain time frame or the BCC's actions are nullified. Be aware of your deadlines! 8. The document was approved by the BCC on 7/13/2021 and all changes made during N/A is not the meeting have been incorporated in the attached document. The County Y�P an option for, Attorney's Office has reviewed the changes,if applicable. 5" this line. 9. Initials of attorney verifying that the attached document is the version approved by the N/A is not BCC,all changes directed by the BCC have been made,and the document is ready for the De an option for Chairman's signature. this line. I:Forms/County Forms/BCC Forms/Original Documents Routing Slip WWS Original 9.03.04,Revised 1.26.05,Revised 2.24.05;Revised 11/30/12 17A MEMORANDUM Date: July 19, 2021 To: Eric Fey, Principal Project Manager PU Engineering & Project Management From: Teresa Cannon, Deputy Clerk Minutes & Records Department Re: Resolution 2021-153: Amending the Collier County Water-Sewer District's Utilities Standards Manual Attached for your records is a scanned copy of the document referenced above, (Item #17A) adopted by the Board of County Commissioners on Tuesday, July 13, 2021. The original document will be held in the Minutes and Record's Department for the Board's Official Record. If you have any questions, please feel free to call me at 252-8411. Thank you. Attachment 1 7 A RESOLUTION NO. 2021 - 1 5 3 A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER-SEWER DISTRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE NO. 2004-31, AS AMENDED, KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; AND PROVIDING FOR AN EFFECTIVE DATE TO COINCIDE WITH THE COMPANION AMENDING ORDINANCE. WHEREAS, on May 11, 2004, as Agenda Item 8 D, the Board of County Commissioners as the Ex Officio Governing Board of the Water-Sewer District (Board) concurrently adopted Collier County Ordinance No. 2004-31, entitled the Collier County Utilities Standards and Procedures Ordinance (the "Ordinance"), and the Collier County Water-Sewer District Utilities Standards Manual, ("Manual"), including all of the Manual's exhibits, and WHEREAS Ordinance No. 2004-31 is codified in Chapter 134, Article III of the Collier County Code of Laws and Ordinances; and WHEREAS, since the 2004 adoption of the Manual it has become necessary to make updates that reflect current standards in design and preparation of plans and specifications for all utilities construction projects; and WHEREAS, after input from stakeholders staff has recommended that the Board adopt this Resolution to approve amendments to the Manual as identified in the attached Exhibit "A"; and WHEREAS, Section 134-61 of the Code of Laws and Ordinances requires the Manual to be amended by Resolution of the Board under the scheduled public hearings or the summary agenda section; and WHEREAS, it is in the interest of the health, safety, and welfare that this Resolution be adopted. [Space Intentionally Left Blank] [19-EIS-04145/1637733/2] Page 1 of 2 cy 17q NOW, THEREFORE, BE IT RESOLVED BY THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND EX-OFFICIO GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, that: The amendment of the Collier County Water-Sewer District Utilities Standards Manual as provided in attached Exhibit "A" is hereby approved and shall take effect upon the filing of Ordinance No. 2021- 24 with the Florida Department of State. This Resolution adopted after motion, second and majority vote, this 13th day of July, 2021. BOARD OF COUNTY COM4ISSIONERS COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, FLORIDA AND(? EX-OFFICIO ATTkSq^of 0, GOVERNING BOARD OF T`HE COLLIER 7. CRYSTAL I 'K 7�EL, CLERK COUNT ER-SEWER IiS' 'RICT � By' igt25t 'S iQ Cfigi TWOU ty Clerk P nny Tayl Chairman Approved as to Form and Legality: Derek D. Perry Assistant County Attorney \/� Agenda 5174 Date /� R e y' /1 ::spray silk [19-EIS-04145/1637733/2] Page 2 of 2 17 , EXHIBIT GG » Table of Contents • Section 1 — Design Criteria, Part 3 "Wastewater Collection and Transmission Systems," Subsection 3.3 "Wastewater Pump Stations" • Section 2—Technical Specifications o Section 330130.16 "Televising and Inspection of Gravity Sewer Systems" o Section 330502 "High Density Polyethylene (HDPE) Pipe and Fittings" • Section 4—Appendices, Appendix D: Utilities Conveyance Checklist 1 7 A Section 1 —Design Criteria, Part 3 "Wastewater Collection and Transmission Systems," Subsection 3.3 "Wastewater Pump Stations" design shall consider the potential for damage or interruption of operation due to flooding. Pump station structures and electrical and mechanical equipment shall be designed to be protected from physical damage by the 100-year flood event. Pump stations shall be designed to remain fully operational and accessible during the 25-year flood event. Pump stations shall be designed to avoid operational problems from the accumulation of grit. Pump stations shall be designed to be readily accessible by maintenance vehicles, including pumper trucks, during all weather conditions. Pump stations shall be designed and located on the site to minimize adverse effects from odors, noise, and lighting. Pump stations shall be located on the site to have a minimum separation of 20 feet from the edge of the CUE for the pump station to edge of a body of water and 15 feet from the edge of the CUE for the pump station to a residential structure (including appurtenances). The effective volume of wet wells shall be based on design average flows and a filling time not to exceed 30 minutes unless the facility is designed to provide flow equalization. The pump manufacturer's duty cycle recommendations shall be utilized in selecting the minimum cycling time. Pump stations requiring a pump motor of twenty horsepower or greater shall operate by a VFD (variable frequency drive) that varies the operating speed of the pump based on wet well water levels. Pump stations shall have a compacted earth berm on three sides with 3:1 slopes to divert liquid toward the ROW. Top of berm shall be 12 inches wide and six inches higher than back of curb (with curb) or edge of pavement (without curb). Minimum berm height shall be six inches. When a pump station has a peak design flow coming into the station greater than 500 gpm, contact Public Utilities Engineering and Project Management Department for specifications. A pump station that is connected connects directly to the a County force main from a subdivision or site development, where multiple pump stations are or will be connected to said force main-(Community Pump Station),and any pump station that receives flow from one or more upstream pump stations or discharges through a force main 12 inches or larger (see FAC 62- 604.400 (2)(a)1) shall have uninterrupted pumping capability (standby diesel pump or generator) with three days of fuel storage (compliant with Technical Specification 263213) and a concrete pad for a future odor control system. Except for grinder pump stations, which require Deviation approval, no new private pump stations are allowed. Grinder pump stations are required to have a standard generator receptacle. All other pump stations shall conform to these standards and shall be conveyed to the Collier County Water-Sewer District in accordance with the utilities conveyance policies and procedures outlined in the Collier County Utilities Standards and Procedures Ordinance (Ord. No. 2004-31 as amended). All pump stations shall have water available to them. Available water means a water main is accessible in the adjacent ROW or CUE. Landscaping is not required, per these standards, to be installed around wastewater pump stations. If landscaping is provided, it shall be maintained by the developer, homeowners association, or land owner and shall NOT be located in the CUE. Landscaping, if provided, shall be located as to not block access or interfere with operations. If plant material dies, it is the responsibility of the landscaping owner to replace it. The landscaping shall be maintained to not block telemetry antenna line of site. COLLIER COUNTY DESIGN RITERIA Page 16 of 19 Words s are deletions; words underlined are additions. C I 7 A Section 2 —Technical Specifications SECTION 330130.16 TELEVISING AND INSPECTION OF GRAVITY SEWER SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION OF WORK A. Work specified herein: 1. Furnish all labor, tools, test equipment and materials, including any and all permits required to televise, inspect, video tape, still photograph and document the gravity wastewater collection systems. 1.2 QUALITY ASSURANCE A. Utilize services of competent personnel in the field of TV/video inspection of wastewater collection systems. B. Schedule all work with ENGINEER. C. Equipment used shall be in good working order and provide continuous operation during TV/video tape inspection. D. VHS videotapes or DVDVideo recording media shall be of good visual quality capable of slow motion and pausing without significant reduction of visual quality. 1.3 SUBMITTALS A. Submit to the County Manager or designee a list of equipment and materials to be used on the project, including all permits obtained prior to commencing with the Work. B. Engineer of Record shall certify and Ssubmit to the County Manager or designee a copy of all television inspection log sheets and VHS videotapes or DVDvideo recording media completed. PART 2 MATERIALS 2.1 GENERAL A. Equipment used shall be designed for use in gravity wastewater collection systems. CONTRACTOR has the option of a County approved equal device or other material than that which is specified. Submittals are required prior to commencement of work. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 1 of 6 Words stricken are deletions; words underlined are additions. 17A 2.2 TELEVISION CAMERA A. Camera used shall be 360ee360-degree COLOR RVC camera. Camera shall be operative in 100% relative humidity and be specifically designed for the environment. Camera shall have an integral lighting system capable of producing clearly focused, well-defined images of the entire periphery of the pipe. Camera shall have an integral depth measurement device capable of clearly showing the depth of vertical dips. The quality of video picture and definition provided shall be to the satisfaction of the ENGINEER and, if unsatisfactory, equipment shall be removed and replaced with satisfactory equipment. 2.3 MONITOR A. A--I4High resolution TV monitor screenvideo shall be used. Quality of monitor video shall be to the satisfaction of the County Manager or designee. 2.4 VIDEO TAPE VERIFICATION EQUIPMENT A. Furnish videotape equipment to provide a visual and audio recording of all areas in the pipe. Videotape system at the site shall be capable of rewind, play back, slow motion and stop motion. The videotape shall be 1/2 inch color VHS,equipped with an audio channel for clearly recording the camera locations and operator observations (cracks, leaks, service connections, etc.). The system shall continuously indicate distance, in feet, from manhole to manhole and the manhole-to-manhole run numbers on the video recording. 2.5 WINCHES A. Furnish variable speed powered remote controlled winches for upstream and downstream manhole locations to control two-way movement of the camera. If a self-propelled camera is used, winches are not necessary. 2.6 POWER SUPPLY A. Power supply shall be continuous. If night operations occur, supply all labor, power and lighting equipment for operations, traffic safety, permits, etc. PART 3 EXECUTION 3.1 GENERAL A. All sanitary sewer gravity lines shall be televiewed televised at the CONTRACTOR's expense_; and a A videotape of the subject mains shall be provided prior to preliminary final acceptance and at the 1 year warranty Televiewing may only occur after the stabilized subgrade has been installed and satisfactory density tests have been submitted to Collier County Utilities. The sewer video inspection shall include rotating the camera lens to inspect the interior of each sewer lateral. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 2 of 6 Words stricken are deletions; words underlined are additions. CAO 17A B. Demonstrate the ability of the TV/video equipment (camera/light/video tape/audio/ photograph system) to the satisfaction of the County Manager or designee. Distance meter shall be furnished on the video tape recording. Meter shall be checked using distances between manholes. Meter distances and actual distances shall be consistent. Depth measurement device shall be visible in the video recording during movement of the camera in the pipe. 3.2 TELEVISING/INSPECTION A. Inspection shall be done one manhole section at a time. Stop flow into the section being inspected prior to video inspection, unless otherwise approved in writing by the County Manager or designee. B. Locate video vehicle on upstream side of manhole. Video tape in the downstream direction such that camera movement is with the flow. C. Insert the camera in the upstream manhole after flow restrictions required have been accomplished. Flow into the system being inspected shall be stopped, with the exception of service laterals into the system being inspected. Move camera through the pipe line pipelines at a moderate speed not exceeding 30 feet per minute. Stop camera at locations where one or more of the following conditions is observed: 1. Infiltration/inflow sources. 2. Service Laterals. 3. Structural defects including broken pipe; collapsed or collapsing pipe, cracks, deterioration, punctures, etc. 4. Abnormal joint conditions such as misalignments, open joints and joints not sealed. 5. Unusual conditions such as root intrusion, protruding pipes, in-line pipe size changes, mineral deposits, grease and obstructions. D. Stop camera long enough for a thorough visual inspection of the conditions. All such conditions as specified above shall be audio recorded on videotape and the inspection log sheet. Move the camera and rotate to obtain optimum view of the conditions. If requested by the County Manager or designee, view problem areas in the opposite direction by pulling the video camera from the opposite direction at no additional cost to the COUNTY. E. While the camera is stopped at each service connection, rotate the camera so as to be able to view the service connection for a length of time that enables a good visual inspection of the service connection for damage and infiltration. Be Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 3of6 Words stricken are deletions; words underlined are additions. 174 responsible for measurements such as service lateral locations, if used for subsequent rehabilitation work. F. When, during the inspection operation, the television camera will not pass through the entire manhole-to-manhole section, set up equipment so that the inspection can be performed from the opposite manhole at no additional cost to the COUNTY. G. Prior to the end of the one year warranty periodfinal acceptance, all manholes will shall be televised and inspected. The complete interior of each manhole shall be inspected and video recorded after the interior coating has been completed. Manhole identification numbers shall be displayed on the video recording, and the recording shall accompany the submittal of the gravity lines inspection. Any deficiencies shall be corrected prior to acceptance by the County. 3.3 DOCUMENTATION A. Furnish a detailed report and videotapes of the system inspected. The minimum information supplied shall be the following: 1. Name and address of CONTRACTOR and the ENGINEER. 2. Name of OWNER, system(s) inspected, and OWNER's representative involved. 3. Log reports: a. Log sheet for each section of pipe b. Separate line for each deficiency and location c. Corresponding videotapes and location of each section of pipe and deficiencies on taevideo. 4. Video tapes shall be labeled with the following information: a. System that is video taped recorded (street name and manhole to manhole numbers) and log report number corresponding to video tape b. Date video was tapedrecorded c. CONTRACTOR's name and representative d. OWNER's name B. All tapes videos shall be rendered unable to be taped over after they are completed. Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 4 of 6 Words stricken are deletions; words underlined are additions. 17A 3.4 MAINTENANCE OF TRAFFIC A. Be responsible for all maintenance of traffic around work site. CONTRACTOR shall maintain traffic in accordance to all federal, state and local regulations. At no additional cost to the COUNTY, submit a Maintenance of Traffic Plan, for review and approval by Collier County DOT as necessary, prior to commencing work. Obtain all necessary permits prior to commencing work, at no additional cost to the COUNTY. B. MOT shall also include construction and maintenance of any necessary detour facilities, furnishings, installing and maintaining of traffic control and safety devices during construction, control of dust, and any other special requirements for safe and expeditious movement of traffic around or through the work site. C. Be responsible for coordination with all affected agencies when roadways will be closed or traffic will be detoured. No detours or roadway closings shall be permitted unless specifically approved in writing by the County Manager or designee or ENGINEER. END OF SECTION Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 5 of 6 Words stricken are deletions; words underlined are additions. 174 NO TEXT FOR THIS PAGE Section 330130.16 COLLIER COUNTY TELEVISING AND INSPECTION OF TECHNICAL SPECIFICATIONS GRAVITY SEWER SYSTEMS Page 6 of 6 Words stricken are deletions; words underlined are additions. CAc➢ 17 A SECTION 330502 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required to install High Density Polyethylene (HDPE) pressure pipe, fittings, and appurtenances as shown on the Drawings and specified in the Contract Documents. B. High Density Polyethylene (HDPE) — Collier County Utilities has the option of approving the use of HDPE for pipeline crossings of roadways, ditches, canals, and environmentally sensitive lands. HDPE mains shall have the same equivalent internal diameter and equivalent pressure class rating as the corresponding PVC pipe, unless otherwise approved by the County Manager or designee. For all roadway crossings requiring casing pipe, a steel or DR 11 HDPE casing pipe must be provided. The Department of Transportation having jurisdiction of said road and right-of-way must grant specific approval. 1.2 REFERENCED STANDARDS A. All standard specifications, i.e., Federal, ANSI, ASTM, etc., made a portion of these Specifications by reference, shall be the latest edition and revision thereof. 1.3 QUALIFICATIONS A. Furnish all HDPE pipe, fittings, and appurtenances by a single manufacturer who is fully experienced, reputable and qualified in the manufacture of the items to be furnished. B. Installer Certification is required for the CONTRACTOR installing thermally butt- fused HDPE pipe. 1.4 SUBMITTALS A. Submit to the ENGINEER, a list of materials to be furnished, the names of the suppliers, and the appropriate shop drawings for all HDPE pipe and fittings. B. Submit the pipe manufacturer's certification of compliance with the applicable sections of the Specifications. C. Submit shop drawings showing installation method and the proposed method and specialized equipment to be used. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 1 of 9 Words stricken are deletions; words underlined are additions. 17A 1.5 INSPECTIONS AND TESTS A. All work shall be inspected by the County Manager or designee who shall have the authority to halt construction if, in his opinion, these specifications or standard construction practices are not being followed. Whenever any portion of these specifications is violated, the County Manager or designee, may order further construction to cease until all deficiencies are corrected. 1.6 WARRANTY AND ACCEPTANCE A. Warrant all work to be free from defects in workmanship and materials for a period of one year from the date of completion of all construction and final utility acceptance. If work meets these specifications, a letter of acceptance, subject to the erne-one-year warranty period, shall be given at the time of completion. A final • n upon final inspect•^^ t the end ^f the-ear " warranty period, provided the work still complies with these specifications. In the event deficiencies are discovered during the warranty period, the CONTRACTOR shall correct them without additional charge to the COUNTY before final acceptance, or the COUNTY willmay otherwise correct them an4by drawing upon the Utilities Performance Security for reimbursement of costs. During the warranty period, the ENGINEER COUNTY will determine if warranty repairs or replacement work shall be peed by the CONTRACTORis needed. The decision of the ENGINEER COUNTY shall be binding upon the CONTRACTOROWNER. pipe. PART 2 PRODUCTS 2.1 POLYETHYLENE PIPE AND FITTINGS A. Provide polyethylene pressure pipe manufactured from PE3408 polyethylene meeting AWWA C906 standards. When specified by the ENGINEER on the construction drawings, as an alternate to PVC, HDPE (ductile iron pipe sized) piping can be used for buried applications. Iron pipe sized (IPS) HDPE piping can be used for below-ground applications as determined by the ENGINEER. B. The diameter of DR 11 HDPE casing pipe provided for roadway crossings or other purposes shall conform to the following. For HDPE pressure carrier pipes, casing spacers are not required when HDPE DR11 (or DR17 for 42" to 54" or DR21 for 63") casing is used. The casing inside diameter shall be a minimum of two inches larger than the carrier pipe's outside diameter. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 2 of 9 Words stricken are deletions; words underlined are additions. 1 7 A C. HDPE to HDPE pipe connections shall be by thermal butt fusion. Thermal fusion shall be accomplished in accordance with the pipe manufacturer and fusion equipment supplier specifications. The CONTRACTOR installing thermal butt fused HDPE pipe shall be certified in this type of work and have a minimum of five years experience performing this type of work. The CONTRACTOR shall provide certification to the Engineer of Record, who will provide the Engineering Review Services Department with the certification. D. Qualification of Manufacturer: The Manufacturer shall have manufacturing and quality control facilities capable of producing and assuring the quality of the pipe and fittings required by these specifications. The Manufacturer's production facilities shall be open for inspection by the County Manager or designee. Qualified manufacturers shall be approved by the County Manager or designee. E. See the County Approved Product List, Appendix F, for manufacturers that are qualified. Products from other manufacturers proposed for the work must receive approval from the County Manager or designee prior to ordering. F. Materials: Materials used for the manufacture of polyethylene pipe and fittings shall be PE3408 high density polyethylene meeting cell classification 345434C or 345434E per ASTM D3350; and meeting Type III, Class B or Class C, Category 5, Grade P34 per ASTM D1248; and shall be listed in the name of the pipe and fitting manufacturer in PPI (Plastics Pipe Institute) TR-4, Recommended Hydrostatic Strengths and Design Stresses for Thermoplastic Pipe and Fittings Compounds, with a standard grade rating of 1600 psi at 73°F. The Manufacturer shall certify that the materials used to manufacture pipe and fittings meet these requirements. G. Polyethylene Pipe: Polyethylene pipe shall be manufactured in accordance with ASTM F714, Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter or ASTM D3035, Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter and shall be so marked. Each production lot of pipe shall be tested for (from material or pipe) melt index, density, % carbon, (from pipe) dimensions and either quick burst or ring tensile strength (equipment permitting). H. Color Identification: HDPE must have at least three equally spaced horizontal colored marking stripes. Permanent identification of piping service shall be provided by adhering to the following colors. Blue — potable water (Underground HDPE pipe shall be one of the following: a. Solid-wall blue pipe; b. Co-extruded blue external skin; or Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 3 of 9 Words stricken are deletions; words underlined are additions. 1 7 A c. White or black pipe with blue stripes incorporated into, or applied to, the pipe wall. White — raw water Green —wastewater, sewage Pantone Purple— non-potable irrigation, reclaimed or reuse water Polyethylene Fittings and Custom Fabrications: Polyethylene fittings and custom fabrications shall be molded or fabricated by the pipe manufacturer. Butt fusion outlets shall be made to the same outside diameter, wall thickness, and tolerances as the mating pipe. All fittings and custom fabrications shall be fully rated for the same internal pressure as the mating pipe. Pressure de-rated fabricated fittings are prohibited. J. Molded Fittings: Molded fittings shall be manufactured in accordance with ASTM D3261, Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing, and shall be so marked. Each production lot of molded fittings shall be subjected to the tests required under ASTM D3261. K. X-Ray Inspection: The Manufacturer shall submit samples from each molded fittings production lot to x-ray inspection for voids,- and shall certify that voids were not found. L. Fabricated Fittings: Fabricated fittings shall be made by heat fusion joining specially machined shapes cut from pipe, polyethylene sheet stock, or molded fittings. Fabricated fittings shall be rated for internal pressure service equivalent to the full service pressure rating of the mating pipe. Directional fittings 16" IPS and larger such as elbows, tees, crosses, etc., shall have a plain end inlet for butt fusion and flanged directional outlets. Part drawings shall be submitted for the approval of the ENGINEER. M. Polyethylene Flange Adapters: Flange adapters shall be made with sufficient through-bore length to be clamped in a butt fusion joining machine without the use of a stub-end holder. The sealing surface of the flange adapter shall be machined with a series of small v-shaped grooves to provide gasketless sealing, or to restrain the gasket against blow-out. N. Back-up Rings and Flange Bolts: Flange adapters shall be fitted with lap joint flanges pressure rated equal to or greater than the mating pipe. The lap joint flange bore shall be chamfered or radiused to provide clearance to the flange adapter radius. Flange bolts and nuts shall be Grade 2 or higher. 2.2 MANUFACTURER'S QUALITY CONTROL A. The pipe and fitting manufacturer shall have an established quality control program responsible for inspecting incoming and outgoing materials. Incoming polyethylene materials shall be inspected for density, melt flow rate, and Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 4 of 9 Words stricken are deletions; words underlined are additions. CAO 17A contamination. The cell classification properties of the material shall be certified by the supplier; and verified by Manufacturer's Quality Control. Incoming materials shall be approved by Quality Control before processing into finished goods. Outgoing materials shall be checked for: 1. Outside diameter, wall thickness, and eccentricity as per ASTM D2122 at a frequency of at least once/hour or once/coil, whichever is less frequent. 2. Out of Roundness at frequency of at least once/hour or once/coil, whichever is less frequent. 3. Straightness, inside and outside surface finish, markings and end cuts shall be visually inspected as per ASTM F714 on every length of pipe. B. Quality Control shall verify production checks and test for: 1. Density as per ASTM D1505 at a frequency of at least once per extrusion lot. 2. Melt Index as per ASTM D1238 at a frequency of at least once per extrusion lot. 3. Carbon content as per ASTM D1603 at a frequency of at least once per day per extrusion line. 4. Quick burst pressure (sizes thru 4-inch) as per ASTM D1599 at a frequency of at least once per day per line. 5. Ring Tensile Strength (sizes above 4-inch equipment permitting) as per ASTM D2290 at a frequency of at least once per day per line. 6. ESCR (size permitting) as per ASTM F1248 at a frequency of at least once per extrusion lot. C. X-ray inspection shall be used to inspect molded fittings for voids, and knit line strength shall be tested. All fabricated fittings shall be inspected for joint quality and alignment. 2.3 COMPLIANCE TESTS A. In case of conflict with Manufacturer's certifications, the CONTRACTOR, ENGINEER, or County Manager or designee may request re-testing by the manufacturer or have re-tests performed by an outside testing service. All re- testing shall be at the requestor's expense,- and shall be performed in accordance with the Specifications. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 5 of 9 Words strickenstfiekenr are deletions; words underlined are additions. S 17 * B. Installation shall be in accordance with Manufacturer's recommendations and this specification. All necessary precautions shall be taken to ensure a safe working environment in accordance with the applicable codes and standards. PART 3 EXECUTION 3.1 INSTALLATION OF HIGH HIGH-DENSITY POLYETHYLENE PRESSURE PIPE AND FITTINGS A. Install all high high-density polyethylene (HDPE) pressure pipe by direct bury, directional bore, or a method approved by the COUNTY or ENGINEER prior to construction. If directional bore is used, or if directed by the County Manager or designee or ENGINEER, surround the entire area of construction by silt barriers. Install all high high-density polyethylene pressure pipe and fittings in accordance with Manufacturer's recommendations, and this specification. Take all necessary precautions to ensure a safe working environment in accordance with the applicable codes and standards. 3.2 HEAT FUSION JOINING A. Make joints between plain end pipes and fittings by butt fusion, and joints between the main and saddle branch fittings by using saddle fusion using only procedures that are recommended by the pipe and fitting Manufacturer. Ensure that persons making heat fusion joints have received training and certification for heat fusion in the Manufacturer's recommended procedure. Maintain records of trained personnel, and shall certify that training was received not more than 12 months before commencing construction. External and internal beads shall not be removed. 3.3 MECHANICAL JOINING A. HDPE pipe and fittings shall be fused together by heat welding when possible. HDPE pipe and fittings may be joined together or to other materials by means of flanged connections with back-up rings, by mechanical joint adapter with glands, or mechanical couplings designed for joining HDPE pipe or for joining HDPE pipe to another material. A stainless stainless-steel sleeve insert shall be used with a mechanical coupling. Mechanical couplings shall be fully pressure rated and fully thrust restrained such that when installed in accordance with manufacturer's recommendations, a longitudinal load applied to the mechanical coupling will cause the pipe to yield before the mechanical coupling disjoins. 3.4 BRANCH CONNECTIONS A. Make branch connections to the main with saddle fittings or tees. Saddle fuse polyethylene saddle fittings to the main pipe. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 6of9 Words stricken are deletions; words underlined are additions. 17A 3.5 EXCAVATION A. Excavate trenches in conformance to this specification, the plans and drawings, or as authorized in writing by the County Manager or designee, and in accordance with all applicable codes. Remove excess groundwater. Where necessary, shore or reinforce trench walls. 3.6 LARGE DIAMETER FABRICATED FITTINGS A. Butt fuse fabricated directional fittings 16" IPS and larger to the end of a pipe. Make up the flanged directional outlet connections in the trench. 3.7 MECHANCIAL JOINT AND FLANGE INSTALLATION A. Install mechanical joints and flange connections in accordance with the Manufacturer's recommended procedure. Center and align flange faces to each other before assembling and tightening bolts. Do not use the flange bolts to draw the flanges into alignment. Lubricate bolt threads, and fit flat washers under the flange nuts. Tighten bolts evenly according to the tightening pattern and torque step recommendations of the Manufacturer. At least one hour after initial assembly, re-tighten flange connections following the tightening pattern and torque step recommendations of the Manufacturer. The final tightening torque shall be 100 ft-lbs or less as recommended by the Manufacturer. 3.8 FOUNDATION AND BEDDING A. Lay pipe on grade and on a stable foundation. Remove unstable or mucky trench bottom soils, and install a 6-inch foundation or bedding of compacted Class I material to pipe bottom grade. Remove excess groundwater from the trench before laying the foundation or bedding and the pipe. A trench cut in rock or stony soil shall be excavated to 6 inches below pipe bottom grade; and brought back to grade with compacted Class I bedding. Remove all ledge rock, boulders, and large stones. 3.9 PIPE HANDLING A. When lifting with slings, use only wide fabric choker slings to lift, move, or lower pipe and fittings. Do not use wire rope or chain. Slings shall be of sufficient capacity for the load; and shall be inspected before use. Do not use worn or defective equipment. 3.10 TESTING A. Hydrostatic Pressure Testing: Pressure test and flush HDPE pipes after swabbing in accordance with Section 022501 and 025400. Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 7 of 9 Words s# ieken are deletions; words underlined are additions. cto 17A END OF SECTION Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 8 of 9 Words strickcn are deletions; words underlined are additions. 17A NO TEXT FOR THIS PAGE Section 330502 COLLIER COUNTY HIGH DENSITY POLYETHYLENE TECHNICAL SPECIFICATIONS (HDPE) PIPE AND FITTINGS Page 9 of 9 Words strieken are deletions; words underlined are additions. Section 4—Appendices, Appendix D: Utilities Conveyance Checklist 1 7 A Utilities Conveyance Checklist POTABLE WATER, NON-POTABLE IRRIGATION WATER AND WASTEWATER FACILITIES ACCEPTANCE Today's Date: Project Name: Original Utility Project No. PL#: (AR/PL): Submittal Requirements N/A review acce Itempted Item Needed Notes 1, ❑ ❑ ❑ Final Utility Conveyance Acceptance Application 2. ❑ ❑ ❑ Addressing Checklist (ID number or Folio number of Property) Legal Documents In Item Item Needed Notes N/A review accepted 1. ❑ ❑ ❑ Attorney's Affidavit 2. ❑ ❑ ❑ Owner's Affidavit 3. ❑ ❑ ❑ Warranty Deed/Bill of Sale with Exhibit B per Utilities Standards and Procedures Ordinance Section 134-60(b)(4), Code of Laws and Ordinances10.2.6 4. ❑ El ❑ Utilities Facilities Securities Subordination (required when any security interest in the utility facilities/systems is involved). UCC-1(s)can be subordinated by a Subordination or by use of UCC-3(s)if not released by Subordination. 5. ❑ ❑ ❑ Deed of Utility Easement- Copy of last Deed that conveyed title of the Associated Real Property and Copy of all Utility Easements then being conveyed to the County, including legal description with Surveyor's Sketch of Easement. (Utility easements are not required provided all utility facilities then being conveyed are in public right-of way, are in then existing utility easements, or are in CUEs) ❑ ❑ ❑ Utilities Performance Security (UPS) per Utilities Standards and Procedures Ordinance Section 134-58(e), Code of Laws and Ordinances10% Of Total Cost Final Obligations cash bond of not less than $1,000 (AR 5930&above) 7. ❑ ❑ ❑ Final Release of Lien from Utility Contractor for the system(s) or portion(s) thereof constructed Page 1 of 3 Rev. 7/20182/2021 Words stricken are deletions; words underlined are additions. 0 CHECKLIST 1 WATER & SEWER FACILITIES ACCEPTANCE COUNTY ORDINANCE 97-17, AS AMENDED Page 2 . ❑ ❑ ❑ Facilities Lease (when applicable) . U U 0 Facilities Lease (including Sub Developer) use Form 10.1 . ❑ ❑ ❑ Final Attorney's Affidavit (provide upon recording legal documents) ests, Certifications and Supplemental Documents N/A In Item Notes review accepted Item Needed 1. ❑ ❑ ❑ Sewer Video of constructed gravity sewer (Sewer Report & Master Utility Sheet) 2. ❑ ❑ ❑ Certification of pressure testing of wastewater force mains by Engineer of Record 3. ❑ ❑ ❑ Certification of the infiltration/exfiltration tests for the sewer lines by Engineer of Record 4. ❑ ❑ ❑ Coating certification from the manufacturer or a professional testing laboratory for all manholes, wet wells and valve vault. 5. ❑ ❑ ❑ Lift station(s) start up report(s) 6. ❑ ❑ ❑ Electrical Contractor's certification of Lift Station electric service wire sizing and voltage drop pursuant to National Electrical Code Specifications 7. ❑ ❑ ❑ Start-up and successful testing of Data Flow telemetry equipment (AR-7936&above) 8. ❑ ❑ ❑ Certification of pressure testing of water and non-potable irrigation mains by Engineer of Record 9. ❑ ❑ ❑ Letter by Engineer certifying that: • All water, non-potable irrigation and/or sewer facilities are located within the public right-of-way or dedicated easements • All the utilities system(s), or portion(s) thereof, has been constructed in accordance with County Ordinances and Regulations, including the required color for piping 10. ❑ ❑ ❑ One year (1) Warranty on work performed and system(s) or portion(s) thereof installed by Utilities Contractor 11. ❑ ❑ ❑ Engineer's Final Payment Confirmation 12. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for WATER facilities (including interim facilities, if applicable); 13. ❑ ❑ ❑ DEP WATER Certification approval to be forwarded when received Page 2 of 3 I Rev.07/20182/2021 Words stricken are deletions; words underlined are additions. CHECKLIST / !�"� A WATER& SEWER FACILITIES ACCEPTANCE COUNTY ORDINANCE 97-17, AS AMENDED Page 3 14. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for SEWER facilities (including interim facilities, if applicable); 15. ❑ ❑ ❑ DEP SEWER Certification approval to be forwarded when received 16. ❑ ❑ ❑ DEP Certification Form and copy of General Permit for (RECLAIMED) NON-POTABLE IRRIGATION WATER facilities (including interim facilities, if applicable); In-service Letter to be forwarded when received 17. ❑ ❑ ❑ Lab results on bacteriological tests for potable water mains 18. ❑ ❑ ❑ Satisfactory Test Reports and Certification of backflow device by Certified Laboratory. 19. ❑ ❑ ❑ Verification of Final Cost (Include materials and labor, misc.) Cost breakdown —Contributory Assets for County/Private Materials (materials only) (i.e.detailed quantities,sizes, unit cost,total cost,etc) 20 ❑ ❑ ❑ Letter from the Fire District regarding ownership and maintenance of fire hydrants 21. ❑ ❑ ❑ Signed copy of field fire flow testing by the applicable Fire Control District Engineering Documents N/A in item review accepted Item Needed Notes 1. ❑ ❑ ❑ One (1) complete set of Record Drawings to include all utilities and all related underground work signed and sealed by the Engineer of Record for potable water, non-potable irrigation water and / or wastewater system(s) or portion(s) thereof 2. ❑ ❑ ❑ One (1) computer-generated disk of Record Drawings in CAD and PDF format per Utilities Standards and Procedures Ordinance Section 134-58(e), Code of Laws and Ordinancesin accordance with Section 10.4: Record Drawings of the Utilities Standards and Procedures Ordinance 3. ❑ ❑ ❑ Longitude and latitude shall appear on detail sheet. (AR-7936&above) Office Use Only below this line ❑W ❑W/S ❑S ❑IRR Page 3 of 3 Rev.07/20182/2021 Words stricken are deletions; words underlined are additions.