Agenda 03/24/2020 Item #16C 2 (FPL Easement - Resource Recovery Park)03/24/2020
EXECUTIVE SUMMARY
Recommendation to approve an Easement to Florida Power & Light Co. for installation of
electrical service for the landfill deep injection well production and operation, at the Collier County
Resource Recovery Park at 3959 City Gate Boulevard North.
OBJECTIVE: To obtain approval of the FPL Easement to provide electrical service to the deep
injection well production and operation.
CONSIDERATIONS: The Public Utilities Department is responsible for the construction, operation,
and maintenance of the Collier County Landfill leachate deep injection well. The Collier County Landfill
is a 310.97-acre Class-I solid waste management facility that accepts incoming solid waste six days per
week. As a result of landfilling waste, leachate is produced and is collected via the landfill leachate
collection system and transferred to a pump station. The leachate is pumped from the pump station to the
sanitary sewer collection system flowing to South County Water Reclamation Facility for treatment. The
leachate volume makes up approximately 100,000 gallons per day of flow (during the wet season) and
contributes to nitrogen concentrations requiring treatment within the waste stream process. Furthermore,
the pipe network in place that transports this leachate volume is located under highway 75 and consists of
aged ductile iron pipe. As a result, the deep injection well was designed to serve as an industry standard,
long term solution for leachate disposal and relieve the wastewater treatment plant of this high volume
and nutrient rich flow. The deep injection well drilling was approved by the Board of County
Commissioners on October 8, 2019.
In order for Florida Power & Light Co. (hereafter “FP&L”) to provide the necessary power for the
installation of the deep injection well, it will be necessary to execute and record the attached Easement
(Business) to FP&L.
The Easement comprises a total of 8,480 square feet or 0.19 acres of land, more or less, as shown and
described on Exhibit “A” of the Easement.
The Easement has been reviewed and approved by Solid & Hazardous Waste Management and the CAO.
FISCAL IMPACT: Recording costs shall not exceed twenty-seven ($27.00) dollars and will be paid
from the Solid Waste Capital Fund (474).
LEGAL CONSIDERATIONS: This item is approved as to form and legality and requires majority vote
for approval. - JAB
GROWTH MANAGEMENT IMPACT: There is no impact to the Collier County Growth
Management Plan.
RECOMMENDATION: That the Board of County Commissioners approves the attached Easement,
authorizes the Chairman to execute the Easement, and directs the County Manager or his designee to
proceed to follow all appropriate closing procedures and to record the Easement in the Public Records of
Collier County, Florida.
PREPARED BY: Deborah Goodaker, Property Acquisition Specialist, Facilities Management Division
16.C.2
Packet Pg. 490
03/24/2020
ATTACHMENT(S)
1. FPL Easement w-LDS (PDF)
16.C.2
Packet Pg. 491
03/24/2020
COLLIER COUNTY
Board of County Commissioners
Item Number: 16.C.2
Doc ID: 11870
Item Summary: Recommendation to approve an Easement to Florida Power & Light Co. for
installation of electrical service for the landfill deep injection well production and operation, at the Collier
County Resource Recovery Park at 3959 City Gate Boulevard North.
Meeting Date: 03/24/2020
Prepared by:
Title: Property Acquisition Specialist – Facilities Management
Name: Deborah Goodaker
03/02/2020 11:42 AM
Submitted by:
Title: Director - Facilities Management – Facilities Management
Name: Damon Grant
03/02/2020 11:42 AM
Approved By:
Review:
Facilities Management Toni Mott Additional Reviewer Completed 03/02/2020 12:01 PM
Public Utilities Operations Support AmiaMarie Curry Additional Reviewer Completed 03/02/2020 1:25 PM
Solid and Hazardous Waste Kari Hodgson Additional Reviewer Completed 03/02/2020 3:39 PM
Solid and Hazardous Waste Dayne Atkinson Additional Reviewer Completed 03/02/2020 3:51 PM
Facilities Management Damon Grant Director - Facilities Completed 03/02/2020 4:08 PM
Public Utilities Department Dan Rodriguez Additional Reviewer Completed 03/02/2020 4:15 PM
Public Utilities Department Drew Cody Level 1 Division Reviewer Completed 03/03/2020 9:30 AM
Public Utilities Department George Yilmaz Level 2 Division Administrator Review Completed 03/03/2020 11:57 AM
County Attorney's Office Jennifer Belpedio Level 2 Attorney of Record Review Completed 03/03/2020 1:45 PM
County Attorney's Office Jeffrey A. Klatzkow Level 3 County Attorney's Office Review Completed 03/03/2020 1:48 PM
Office of Management and Budget Debra Windsor Level 3 OMB Gatekeeper Review Completed 03/03/2020 2:51 PM
Office of Management and Budget Susan Usher Additional Reviewer Completed 03/04/2020 7:51 AM
Budget and Management Office Ed Finn Additional Reviewer Completed 03/04/2020 11:32 AM
County Manager's Office Nick Casalanguida Level 4 County Manager Review Completed 03/14/2020 2:53 PM
Board of County Commissioners MaryJo Brock Meeting Pending 03/24/2020 9:00 AM
16.C.2
Packet Pg. 492
EASEMENT
(BUSTNESS)
Work Request No. 9095396
Sec. 25 & 36, Iwp. 49 S., Ronge 26 E
Porcel LD.: 00289720004
(Mointoined by County Approiser)
Fo(m 3722 (Stocked) Rev 6/ I I
Approved os lo form ond legolily:
This Form Approved by FPL & CAO
Nome: Potrick Riley
Compony: Florido Power & tight
Address: 4 I 05 I sth Ave S, Noples FL 341 I 6
Ihe undersigned. in considerotion of lhe poyment of $1.00 ond other good ond voluoble considerotion, the
odequocy ond receipt of which is hereby ocknowledged, gront ond give to Florido Power & Lighl Compony,
ils offilioles, licensees, ogents, successors, ond ossigns ("FPL"), o perpetuol, non-exclusive eosement for the
construction, operotion ond mointenonce of overheod ond underground electric utility focilities (including
wires, poles,guys, cobles, conduits, ond oppurtenonl equipmeni) 1o be instolled from lime lo time; with the
right to reconstruct, improve, odd to, enlorge, chonge lhe voltoge. os wellos the size of, ond remove such
focilities or ony of them within on eosement described os follows:
See Exhlbll "A" ("Eoremenl Areo")
Together with the right to permit ony other person, firm or corporotion 1o oltoch wires lo ony focilities
hereunder ond loy coble ond conduit within the eosement ond lo operote the some for communicotions
purposes; the right of ingress ond egress to lhe eosement oreo of oll limes; the right lo cleor the lond ond
keep it cleored of oll trees, undergrowlh ond olher obstructions within the Eosemenl Areo; to trim ond cul ond
keep trimmed ond cut oll deod, weok. leoning or dongerous trees or limbs oulside of the eosement oreo
which might interfere with or foll upon the lines or systems of communicolions or power lronsmission or
distribuiion; ond further gronls, lo the fullest extenl the undersigned hos the power to gronl, if ot oll, lhe rights
hereinobove gronted on lhe Eosement Areo heretofore described, over, olong, under ond ocross lhe roods,
streels or highwoys odjoining or lhrough soid Eosement Areo.
lN WITNESS WHEREOF, the undersigned hos signed ond seoled lhis instrument on this _ doy of
,20n,
Boord of County Commissioners
Collier County, Florido
By:
BURT L. SAUNDERS, Choirmon
3299 TomiomiTroil E. #303
Noples. Florido 341 l2-57 46
Attest:
CrystolK. Kinzel. Clerk
By
Print Nome
Deputy Clerk
3299 TomiomiTroil E, 4t Flr
Noples, Florido 34112
Jennifer A. Eelpedio, Assistonf Covnf Attomey ,d
@
16.C.2.a
Packet Pg. 493 Attachment: FPL Easement w-LDS (11870 : FPL DIW Easement)
EXHIBIT IIAII
N
200 0 100 200
SCALE: 1" = 200'
400
COLLIER COUNry
(o.R. BOOK2628, PAGE 1174)
N88"43'09"E
10.03'
PROPOSED 1O' WIDE FLORIDA
POWER AND LIGHT EASEMENT
(8,480 SQAURE FEET)N02"51'35"E
55.49's02"51'35"W
55.59'N04"15'35"W
117.70',
s00"11'07"E
14.50',
POINT OF BEGINNING
POINT OF COMMENCEIVIENT
N88'36'04"E
57.90'
s04'15'35"E
117.68',
SOUTHEAST CORNER OF SECTION 25,
TOWNSHIP 49 SOUTH, RANGE 26 EAST,
COLLIER COUNTY FLORIDA.N89'56'21"E 50'PROPOSED 1O'WIDE FLORIDA POWER
tNo1'23'56"WJ
10.00'
s88'36'04"W
63.1 0'
s89"56'21"W 10'N89"51'00"W 2414.57',
1'07"W
10.47',
s89"49'53"W
10.00'
s00"1 1'07"E
5.94'SOUTH LINE OF SECTION 25, TOWNSHIP 49 SOUTH,
RANGE 26 EAST, COLLIER COUNTY, FLORIDA
COLLIER COUNry
(o.R. BOOK 5063, PAGE2207)COLLIER COUNTY
(o.R. BOOK 601, PAGE 806)
"1. l: l',,/
SKETCH OF DESCRIPTION
NOT A SURVEY
N INC.
NO. LB 2464
J
PROFESSIONAL SU AND MAPPER
SEE PAGE 2 FOR LEGAL
DESCRIPTION
FLORIDA CERTIFICATE NO. 5295
NOT VALID WITHOUT THE SIGNATURE AND
THE ORIGINAL RAISED SEAL OF A FLORIDA
LICENSED SURVEYOR AND MAPPER
DATEOFSIGNATURE: Z - ZE . Zoz,- o
COASTAL AND iilARlNE ENGINEERING
ENVIRONMENTAL AND GEOLOGICAL SERVICES
LAND AND IVARINE SURVEY AND MAPPING
PHONE: (239)M3-2324
FAX: (239)643-1 143ww coastalengineenng.mm
E-irail: info@@cifl.@m
ENGINEERING
CONSULTANTS
tNc.
ACECIRNPMPN
SeMng Florida Sine 1977
3106 SOUTH HORSESHOE DRIVE
NAPLES, FLORIDA 34104
SKETCH OF DESCRIPTION oFA pRoposEDrEN (10,) FoorwDE FLoRIDA powERAND
LIGHT EASEMENT LYING IN SECTION 25 AND 36, TOWNSHIP 49 SOUTH, RANGE 26 EAST, COLLIER COUNry
FLORIDA
REVIS ON DESCR PTION
a
49S
20.074 NO DATE BY
DAVIDSON ENGINEERING
I
.i\
16.C.2.a
Packet Pg. 494 Attachment: FPL Easement w-LDS (11870 : FPL DIW Easement)
EXHIBIT IIAII
PROPOSED TEN (10) FOOT W|DE FLORTDA POWER AND LtcHT (FpL)
EASEMENT
LEGAL DESCRIPTION
A TEN (10) FOOT WIDE STRIP OF LAND LYING IN THAT PART OF SECTIONS 25 AND 36,
TOWNSHIP 49 SOUTH, RANGE 26 EAST, COLLIER COUNTY FLORIDA, BEING
DESCRIBED AS FOLLOWS.
COMMENCING AT THE SOUTHEAST CORNER OF SAID SECTION 25,
RUN N89"51'OO''WALONG THE SOUTH LINE OF SAID SECTION FOR A DISTANCE
2,414,57 FEET TO THE POINT OF BEGINNING;
THENCE LEAVING SAID LINE SOO"1,1'07''E FOR A DISTANCE 5.94 FEET;
THENCE S89"48'53''W FOR A DISTANCE 1O.OO FEET;
THENCE NOO'11'07"W FOR A DISTANCE 10.47 FEET;
THENCE 589"56'21''W FOR A DISTANCE 591.10 FEET;
THENCE S88'36'04"W FOR A DISTANCE 63.10 FEET;
THENCE NO1'23'56"W FOR A DISTANCE ,1O.OO FEET;
THENCE N88"36'04''E FOR A DISTANCE 57.90 FEET;
THENCE N04"15'35''W FOR A DISTANCE 117.70 FEET;
THENCE NO2'51'35"E FOR A DISTANCE 55.49 FEET;
THENCE N88"43'08"E FOR A DISTANCE 10.03 FEET;
THENCE 502"51'35"!A/ FOR A DISTANCE 55.59 FEET;
THENCE SO4'15'35"E FOR A DISTANCE 117.68 FEET;
THENCE N89'56'21"E FOR A DISTANCE 596.50 FEET;
THENCE SOO"11'07''E FOR A DISTANCE 14.50 FEET TO THE POINT OF BEGINNING
THE ABOVE DESCRIBES AN AREA OF APPROXIMATELY 8,480 SQUARE FEET OR 0.19
ACRES OF LAND
DAVIDSON ENGINEERING
RJE
25&49S
NO
I:
o
COASTAL AND MARINE ENGINEERING
ENVI RONMENTAL AND GEOLOGICAL SERVICES
LAND AND MARINE SURVEY AND MAPPING
PHONE: (239)643-2324
FAX (239)643-1143
M.COaStalengtneenng @m
E-Mail: info@ecm.6m
A CECI GROUP COMPNY
SeNing Florida Sine 1977
ENGINEERING
CONSULTANTS
tNc.
3106 SOUTH HORSESHOE DRIVE
NAPLES, FLORIDA 34104
SKETCH OF DESCRIPTION oFApRoposEDrEN(10)FoorwDEFLoRIDApowERAND
LIGHT EASEMENT LYING IN SECTION 25 AND 36, TOWNSHIP 49 SOUTH, RANGE 26 EAST, COLLIER COUNTY,
FLORIDA
TITLE:
20,074 SKETCH NO DATE BY REVISION DESCRIPTION
16.C.2.a
Packet Pg. 495 Attachment: FPL Easement w-LDS (11870 : FPL DIW Easement)