Agenda 07/26/2011 Item #17B7/26/2011 Item 17.B. EXECUTIVE SUMMARY Recommendation to approve a Resolution amending the Collier County Water -Sewer District's Utilities Standards Manual. OBJECTIVE: The public purpose of this Resolution is to provide a technically viable and current Collier County Water -Sewer District Utilities Standards Manual (Manual) that governs the installation of sustainable and safe utilities infrastructure within the county. CONSIDERATIONS: On May 11, 2004, under Agenda Item 8 D, the Board of County Commissioners, as the Ex Officio Governing Board of the Water -Sewer District (Board), concurrently adopted Collier County Ordinance No. 2004 -31, the Collier County Utilities Standards and Procedures Ordinance (Ordinance), and the Collier County Water -Sewer District Utilities Standards Manual (Manual), including all of the Manual's exhibits, as amended. These documents provide county procedures and guidelines for the design and construction of both county constructed and privately constructed utilities systems in Collier County. The Manual, an integral part of the Ordinance, provides engineering and drawing detail sheets for components of utility systems. Public Utilities Division staff coordinated with the Development Services Advisory Committee (DSAC), the Collier Building Industry Association (CBIA), the development community (engineers and contractors), and the Public Utilities Division's water and wastewater operators on the optimal and best value operation and maintenance of utilities infrastructure. These groups, as well as the Public Utilities Division's Planning and Project Management Department and the Growth Management Division's Engineering Services Section, actively participate in monthly utilities discussion group meetings. Over the past year this discussion group, DSAC, and CBIA have reviewed and approved the Manual revisions. The changes to the Manual are listed in the attached Table of Revisions and accompanying sketches. Both are incorporated into the Resolution as Exhibit A. If the Resolution is approved, the effective date of the changes to the Manual will be August 1, 2011, FISCAL IMPACT: A fiscal impact of up to approximately $500 for the advertisement will be paid related to this Executive Summary. LEGAL CONSIDERATIONS: This item is legally sufficient for Board action. Section 134- 51 (c) of the Code of Laws and Ordinances allows the Manual to be amended by Resolution. This item requires a majority vote. - JBW GROWTH MANAGEMENT IMPACT: This project is consistent with and will further the Goals, Objectives, and Policies of the Collier County Growth Management Plan standards to ensure the adequacy and availability of viable public facilities. RECOMMENDATION: That the Board of County Commissioners adopts the attached Resolution amending the Collier County Water -Sewer District Utilities Standards Manual. PREPARED BY: Nathan Beals, Project Manager, Public Utilities Planning and Project Management Department Packet Page -2756- COLLIER COUNTY Board of County Commissioners Item Number: 17.B. 7/26/2011 Item 17.13. Item Summary: Recommendation to approve a Resolution amending the Collier County Water -Sewer District's Utilities Standards Manual. Meeting Date: 7/26/2011 Prepared By Name: Amysue Benker Title: Executive Secretary, 7/8/2011 10:29:50 AM Submitted by Title: Project Manager, Associate,Public Utilities Engine Name: Nathan Beals 7/8/2017 10:29:51 AM Approved By Name: HapkeMargie Title: VALUE MISSING Date: 7/8/2011 2:56:16 PM Name: ChmelikTom Title: Project Manager, Principal, Pubic Utilities Engine Date: 7/11 /2011 8:29:21 AM Name: Paul Mattausch Title: Director- Water,Water Date: 7 /11/2011 11:00:39 AM Name: WhiteJennifer Title: Assistant County Attorney,County Attorney Date: 7/11/2011 4:15:49 PM Name: YihnazGeorge Packet Page -2757- Title: Director - Wastewater,Wastewater Date: 7/12/2011 11:17:46 AM Name: KlatzkowJeff Title: County Attorney, Date: 7/12/2011 3:10:30 PM Name: GreenwaldRandy Title: Management/Budget Analyst,Office of Management & B Date: 7/13/2011 11:20:33 AM Name: SheffieldMichael Title: Manager - Business Operations, CMO Date: 7/18/2011 11:54:20 AM Packet Page -2758- 7/26/2011 Item 17.13. 7/26/2011 Item 17.13. RESOLUTION NO. 2011 - A RESOLUTION OF THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS EX- OFFICIO THE GOVERNING BOARD OF THE WATER -SEWER DISTRICT APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER -SEWER DISTRICT'S UTILITIES STANDARDS MANUAL, WHICH IS AN INTEGRAL PART OF COLLIER COUNTY ORDINANCE, NO. 2004 -31, KNOWN AS THE COLLIER COUNTY UTILITIES STANDARDS AND PROCEDURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE CODE OF LAWS AND ORDINANCES; PROVIDING FOR A DELAYED EFFECTIVE DATE OF AUGUST 1, 2011 FOR THE MANUAL WHEREAS, on May 11, 2004, as Item 8 D. the Board of County Commissioners as the Ex Officio Governing Board of the Water -Sewer District (Board) concurrently adopted Collier County Ordinance No. 2004 -31, entitled the Collier County Utilities Standards and Procedures Ordinance (the "Ordinance "), and the Collier County Water -Sewer Distict Utilities Standards Manual," (Manual), including all of the Manual's exhibits, and WHEREAS Ordinance No. 2004 -31 is codified in Chapter 134, Article III of the Code of Laws and Ordinances; and WHEREAS, since the 2004 adoption of the Manual it has become necessary to make updates that reflect current standards in design and preparation of plans and specifications for all utilities construction projects; and WHEREAS, after input from stakeholders Public Utilities staff has recomtnended that the Board adopt this Resolution to approve amendments to the Manual as identified in Exhibit A: and WHEREAS, Section 134 -61 of the Code of Laws and Ordinances requires the Manual to be amended by Resolution of the Board under the scheduled public hearings or the summary agenda section; and WHEREAS, it is in the interest of the health, safety, and welfare that this Resolution be adopted. NOW, THEREFORE, BE IT RESOLVED BY THE BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS EX- OFFICIO THE GOVERNING BOARD OF THE WATER -SEWER DISTRICT, that: Packet Page -2759- 7/26/2011 Item 17.13. The Collier County Water -Sewer District Utilities Standards Manual, as amended, as identified in Exhibit A, is hereby approved and shall take effect on the I" day of August, 2011. This Resolution adopted after motion, second and majority vote, this _ day of July, 2011. ATTEST: BOARD OF COUNTY COMMISSIONERS OF COLLIER DWIGHT E. BR.00K, COUNTY, FLORIDA, AS EX- OFFICIO THE GOVERNING CLERK BOARD OF THE WATER -SEWER DISTRICT By' Deputy Clerk FRED W. COYLE, CHAIRMAN Approval as to form and legal Sufficiency; Jenri B. White Assist it;i County Auorne�, Packet Page -2760- 7/26/2011 Item 17.13. Exhibit A Table of Revisions Packet Page -2761- 7/26/2011 Item 17.B. COLLIER COUNTY UTILITIES STANDARDS MANUAL TABLE OF REVISIONS COLLIER COUNTY PUBLIC UTILITIES PLANNING AND PROJECT MANAGEMENT DEPARTMENT AS OF 07/2011 CHANGES TO UTILITIES Section Sub - Section/ Detail # Revision Summary 1 1.4 Update meter requirements to only require leak detection meters on fire service lines. 3 W -8 Add detail, previously deleted, and update. 3 W -9 Update detail. 3 W -9A Update detail. 3 W -10 Delete detail. 3 W -11 Add detail, previously deleted, and update. 3 W -11A Update detail. 3 W -15 Delete detail. 3 W -16 Add detail, previously deleted, and update. 4 Appendix G Update list. Page 1 of 1 Packet Page -2762- 7/26/2011 Item 17.B. Proposed Revision to Section 1, Design Criteria Proposed additions in text are noted in bold. Proposed deletions in text are noted in strike - through. Section 1, Design Criteria, Page 6, text revisions in 1.4 1.4 Fire Service Systems All private fire service systems for sprinkler systems, wet standpipe systems, and privately - owned or controlled distribution systems shall be metered iNith a Fire 98P.10Ge, long Sized, FRete aad shall be installed with an appropriate back flow prevention device with a leak detection meter. The meter shall be owned and maintained by the private service owner. The COUNTY requires all privately -owned backflow devices to be certified at the time of installation and on an annual basis by a Certified Back Flow Tester (University of Florida, TREEO Center, or equivalent certification program). The results shall be submitted to the County Manager or designee. The County Manager or designee will require all privately owned metering devices to be certified for accuracy at the time of installation. Fire meter devices using a three quarter to two inch ( %" to 2 ") metering device shall be re- calibrated to manufacturer's specifications every five (5) years, replaced every ten (10) years, or replaced immediately upon meter failure. Fire meter devices greater than two inches (2 ") shall be re- calibrated to manufacturer's specifications every five (5) years and replaced immediately upon meter failure. The County Manager or designee will inform the owner by mail prior to the due date. Private owner(s) shall submit certification results to the County Manager or designee within sixty (60) days of the due date. 1.4.1 Fire Service Meters for Residential Systems Residential projects such as, but not limited to, single family, multi - family condominiums, trailer parks, mobile home parks, etc. utilizing a master meter shall pass all fire flow through such meter. The meter shall be sized to pass the domestic coincident draft plus rated fire flow at the AWWA pressure loss specifications. 1.4.2 Fire Service Meters for Commercial and Other Non - residential Systems Commercial projects such as, but not limited to, shopping centers, malls, retail, and industrial buildings shall pass all fire flow through a potable master meter or have a separate fire service connection to the water distribution main. The Fire Service meter and isolation valves shall be extended above final grade as shown in the Utilities Detail Drawings. For meter reading purposes, metering devices shall lie within a County Utility Easement (CUE) that shall be dedicated separately to the Board for the appropriate Water -Sewer District or in conjunction with the easements for any on -site utility system(s). The Owner shall purchase and install an alappeved AMR meter and approved backflow devices with a leak detection meter at no expense to the appmpriaie Water -Sewer District. Packet Page -2763- N CONCRETE FOUNDATION FULL LENGTH OF ASSEMBLY (TYP) 4' WIDE, 6' THICK 6' x 6' 10x10 WELDED WIRE MESH - zl GATE VALVE aI a TO THIS POINT 7/26/2011 Item 17.6. DOUBLE CHECK DETECTOR BACKFLOW PREVENTER ASSEMBLY SUPPLIED RUBBER SEALS. UL/FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14 (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) RISING STEM AND RESIUENT SEAT (TYPICAL 2 PLACES) FLANGED GATE VALVE FL0W SERVICE LINE NOTES: 1. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INUNE GATE VALVE AT THE PROPERTY UNE OR RIGHT -OF -WAY LINE. 2. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INUNE GATE VALVE FROM THE COUNTY'S WATER MAIN. 3. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 4. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 7. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 (e.g., RISK OF CHEMICAL ADDITION, MEDICAL FACILITIES, INDUSTRIAL FACILITIES, PROPERTIES USING RECLAIMED WATER, ETC.), EXIST. m Packet Page -2764- W -8 REVISED: JULY 2011 �7 .�. DUCTILE IRON L JIII 111 i 11 L1 � A,11. I IP► • r. -. �\ \\ was of SERVICE LINE NOTES: 1. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INUNE GATE VALVE AT THE PROPERTY UNE OR RIGHT -OF -WAY LINE. 2. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INUNE GATE VALVE FROM THE COUNTY'S WATER MAIN. 3. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 4. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 7. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 (e.g., RISK OF CHEMICAL ADDITION, MEDICAL FACILITIES, INDUSTRIAL FACILITIES, PROPERTIES USING RECLAIMED WATER, ETC.), EXIST. m Packet Page -2764- W -8 REVISED: JULY 2011 2" REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY SUPPLIED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SIUCONE RUBBER SEALS. UL/FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) PRESSURE GAUGE FIRE PROTECTION METER (SEE COUNTY APPROVED PRODUCT UST, APPENDIX F) UL /FM APPROVED FOR FIRE SERVICE INSTALLATION (FACTORY ASSEMBLED WITH TOP ACCESS STRAINER ONLY)— PRESSURE O� O�pF1 N `MJ 45' OR 90' BEND WITH RETAINER GLANDS MAIN SIZE PER UTILITY PLAN a . 7/26/2011 Item 17.13. OS &Y VALVE CLOSED CURB STOP r12" SPOOL PIECE WITH 2" TAP 2' TEE WITH 3/4' HOSE BIBBS CHECK BACKFLOW PREVENTER Y SUPPLIED WITH AMMONIA BYPASS METER UL/FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) RISING STEM AND RESIDENT SEAT FLANGED GATE VALVE (TYPICALq OF THREE) >!\ 12" SPOOL PIECE \ WITH 2" TAP MAIN SIZE PER UTIUTY PLAN NOTES: 1. ALL ABOVE GROUND PIPE SHALL BE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SH BE STAINLESS STEEL 2. WATER MAIN EXTENSION AND ASSEMBLY IS REQUIRED TO BE FLUSHED, CHLORINATED AND GIVEN BACTERIAL CLEARANCE BY THE WATER DEPARTMENT LAB BEFORE PLACEMENT IN SERVICE. 3. BACKFLOW UNIT AND METER REQUIRES INITIAL CERTIFICATION FOR OPERATION AND ACCURACY WITH RESULTS AND ANNUAL TESTS SUBMITTED TO THE COLLIER COUNTY WATER DEPARTMENT. 4. INSPECTIONS ARE REQUIRED FOR SYSTEM TIE —IN AND ASSEMBLY CONNECTION. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 6. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. S. A REDUCED PRESSURE DEFECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 (e.g., RISK OF CHEMICAL ADDITION, MEDICAL FACILITIES, INDUSTRIAL FACIUTIES, PROPERTIES USING RECLAIMED WATER, ETC.), EXIST. TEMPORARY BACKFLOW PREVENTER AND FIRE PROTECTION METER TIE —IN ASSEMBLY W -9 NTS REVISED: JULY 2011 Packet Page -2765- r 2" TAP (TYPICAL - OF TWO) 2" CURB STOP - (TYPICAL OF TWO) DOUBLE CHECK DETECTOR BACKFLOW PREVENTER UL /FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) SEAT FLANGED GATE VALVE (TYP) °" TAP (TYPICAL OF NOTES: 'ALL INUNE GATE VE AT PROPERTY OR RIGHT -OF -WAY 0 N (2) 2" TEES WITH 'yi HOSE BIBBS VALVE SETTER (SEE COUNTY APPROVED PRODUCT UST, APPENDIX F) 7/26/2011 Item 17.6. 2" REDUCED PRESSURE BACKFLOW PREVENTER ASSEMBLY, SUPPLIED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS UL /FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS REQUIRED BY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) LOCK OS &Y VALVE CLOSED 1. ALL ABOVE GROUND PIPE SHALL BE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SF BE STAINLESS STEEL 2. WATER MAIN EXTENSION AND ASSEMBLY IS REQUIRED TO BE FLUSHED, CHLORINATED AND GIVEN BACTERIAL CLEARANCE BY THE WATER DEPARTMENT LAB BEFORE PLACEMENT IN SERVICE. 3. BACKFLOW UNIT AND METER REQUIRES INITIAL CERTIFICATION FOR OPERATION AND ACCURACY WITH RESULTS AND ANNUAL TESTS SUBMITTED TO THE COLLIER COUNTY WATER DEPARTMENT. 4. INSPECTIONS ARE REQUIRED FOR SYSTEM TIE -IN AND ASSEMBLY CONNECTION. 5. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 6. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. 8. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 RISK OF CHEMICAL ADDITION, MEDICAL FACILITIES, INDUSTRIAL FACILITIES, PROPERTIES USING RECLAIMED WATER, ETC.), EXIST. W -9A REVISED: JULY 2011 Packet Page -2766- INSTALL INLNE GATE VALVE AT PROPERTY UNE OR RIGHT -OF -WAY LINE o � CUE FIRE PROTECTION METER (SEE COUNTY APPROVED PRODUCT LIST, APPENDIX F) WITH BYPASS. UL /FM APPROVED FOR FIRE SERVICE INSTALLATION (FACTORY ASSEMBLED) (WITH TOP ACCESS FACTORY APPLIED FUSION BONDED EPDXY COATED STRAINER ONLY)--I AIR RELEASE VALVE (SEE COUNTY APPROVED PRODUCT �= UST, APPENDIX F) p 7 BRASS NIPPLE r 12' SPOOL PIECE /- z3 I 0 NSTALL INLINE GATE � wa� VALVE AT PROPERTY �G/ p z LINE OR RIGHT -OF -WAY F,� air LINE �\n F MAIN SIZE PER--:j�tlVD1^O� D1W1Y� � UTILITY PLAN SUPPORT STANDS MJ 45' OR 90' DL ANCHORED TO PAD BEND WITH MJ RETAINER GLANDS (TYP) NOTES: 1. ALL ABOVE GROUND PIPE WILL HALAN D DUCTILE SHALL BE STAINLESS STEEL. 2. (4) VEHICULAR GUARD POSTjff BE DOCUMENTS SUBMITTED FQd0tEVIEW 7/26/2011 Item 17.13. CONCRETE FOUNDATION (TYP) FULL LENGTH OF METER ASSEMBLY; 4' WIDE, 6' THICK REINFORCED 6 X 6 10/10 WELDED WIRE MESH REDUCED PRESSURE BACKFLOW PR 'ENTER ASSEMBLY SUPPLIED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS. UL /FM APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATION AS RED BY COUNTY ORDINANCE AND AWWA (SEE APPROVED BACKFLOW DEV APPENDIX G) ATE VALVE PIECE 12' MINIMUM ABOVE SLAB MAIN SIZE PER UTILITY PLAN PRESSURE CLASS 350. ALL NUTS AND BOLTS CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION 3. AS THIS UNIT WILL REQUIRE ESTING, F TIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO ENT INTERR S. (SEE W -15) 4. ASSEMBLY W OWNS MAI PROPERTY OWNER, STARTING FROM THE FIRST ISOLATION VALVE PRIOR TO ASSEM 5. COUNTY WILIQUIRE DEDICAT11 OF THE MATERIAL UP TO AND PRIOR TO VALVE ON THE ASSEMBLY FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW UNIT REIqlLSAWAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TWE COUNTY WATER DEPARTMENT. 7. ALL PLANTINGS SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 9. ALL COMPONENTS THAT COME INTO CONTACT WITH DRINKING WATER SHALL CONFORM TO NSF STANDARD 61. 10. REFER TO APPROPRIATE SPECIFICATION IN MANUAL FOR GATE VALVES AND APPURTENANCES. FIRE SYSTEM ASSEMBLY DETAIL W-1 0 NTS REVISED: JANUARY 2009 Packet Page -2767- INSTALL INUNE GATE VALVE AT PROPERTY LINE OR RIGHT -OF -WAY UNEy� Cs O A 91 (N AIR VALVE WITH CORPORATION STOP (SEE— COUNTY APPROVED PRODUCT UST, APPENDIX F) 7/26/2011 Item 173. CONCRETE FOUNDATION (TYP) FULL LENGTH OF METER ASSEMBLY; 4' WIDE, 6" THICK REINFORCED 6 x 6 10/10 WELDED WIRE MESH—, STRAINER (TOP ACCESS FACTORY APPUED WK w FUSION BONDED EPDXY COATED STRAINER PREVENTER ASSEMBLY SUPPLIED WITH METER AND ONLY), UL USTED /FM APPROVED ?13 AIR VALVE WITH CORPORATION STOP II (SEE COUNTY APPROVED PRODUCT o UST, APPENDIX F) w= d Z o� aIK I INSTALL INUNE GATE VALVE AT PROPERTY LINE OR RIGHT -OF -WAY UNE MAIN SIZE PER UTIUTY PLAN - NOTES: BRASS NIPPLE 12' SPOOL PIECE 12' II ABOVE SLAB ADJUSTABLE STAINLESS STEEL PIPE SUPPORT STANDS AS REQUIRED ANCHORED 70 PAD (TYR) MJ 45 OR 90 DEGREE BEND WITH MJ RETAINING GLANDS (TYP) MAIN SIZE PI UTILITY PLAN 1. ALL ABOVE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL 2. (4) VEHICULAR GUARD POSTS 70 BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMITTED FOR REVIEW AND APPROVAL. 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACIUTIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INLINE GATE VALVE AT THE PROPERTY LINE OR RIGHT -OF -WAY LINE. 5. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INLINE GATE VALVE FROM THE FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 10. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 RISK OF CHEMICAL ADDITION, M DI L 71 T LAIMED WATER, ETC.), EXIST. NTS W-1 1 REVISED: JULY 2011 Packet Page -2768- DOUBLE CHECK DETECTOR BACKFLOW 3 4' BYPASS / PREVENTER ASSEMBLY SUPPLIED WITH METER AND AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS. BACKFLOW UL /FM APPROVED FOR FIRE SERVICE DEVICE INSTALLATION. INSTALLATION AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) FLANGED GATE VALVE WITH RISING STEM AND RESILENT SEAT (TYP) 12' SPOOL PIECE MAIN SIZE PI UTILITY PLAN 1. ALL ABOVE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL 2. (4) VEHICULAR GUARD POSTS 70 BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMITTED FOR REVIEW AND APPROVAL. 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACIUTIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INLINE GATE VALVE AT THE PROPERTY LINE OR RIGHT -OF -WAY LINE. 5. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INLINE GATE VALVE FROM THE FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 10. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 RISK OF CHEMICAL ADDITION, M DI L 71 T LAIMED WATER, ETC.), EXIST. NTS W-1 1 REVISED: JULY 2011 Packet Page -2768- DOUBLE CHECK DETECTOR BACKFLOW PREVENTER — ASSEMBLY SUPPUED WITH AMMONIA AND CHLORINE RESISTANT SEATS AND SILICONE RUBBER SEALS. UL /FA APPROVED FOR FIRE SERVICE INSTALLATION. INSTALLATI AS REQUIRED BY COUNTY ORDINANCE AND AWWA M -14. (SEE APPROVED BACKFLOW DEVICES, APPENDIX G) FLANGED GATE VALVE WITH RISING STEM AND I RESILIENT SEAT (TYP) I I �Iw VEHICULAR GUARD POST (TYP)� OI� Y �3 I w O aOM 1i - INSTALL INLINE GATE VALVE AT PROPERTY LINE OR RIGHT —OF —WAY LINE CONCRETE FOUNDATION (TY 4' WIDE x 5' LONG, 6' TH REINFORCED 6 x 6 10/10 WIRE MESH CJ 7/26/2011 Item 17.6. i�O�1 11w. �k VALVE SETTER (SEE COUNTY APPROVED —� NOTES. PRODUCT LIST, APPENDIX F) 1. ALL ABOVE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL 2. (4) VEHICULAR GUARD POSTS TO BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMITTED FOR REVIEW AND APPROVAL. 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACIUTIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INUNE GATE VALVE AT THE PROPERTY LINE OR RIGHT —OF —WAY UNE. 5. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INUNE GATE VALVE FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 10. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 (e.g.. RISK OF CHEMICAL ADDITION, MEDIC R, ETC.), IXIST. DETECTOR CHECK ASSEMBLY DETAIL NTS REVISED: JULY 2011 Packet Page -2769- -1 k --I,I� VALVE SETTER (SEE COUNTY APPROVED —� NOTES. PRODUCT LIST, APPENDIX F) 1. ALL ABOVE GROUND PIPE WILL HAVE FLANGED END DUCTILE IRON PIPE, PRESSURE CLASS 350. ALL NUTS AND BOLTS SHALL BE STAINLESS STEEL 2. (4) VEHICULAR GUARD POSTS TO BE INSTALLED AROUND ASSEMBLY. CONFIGURATION TO BE ILLUSTRATED ON CONSTRUCTION DOCUMENTS SUBMITTED FOR REVIEW AND APPROVAL. 3. AS THIS UNIT WILL REQUIRE PERIODIC TESTING, FACIUTIES REQUIRING CONTINUOUS WATER SERVICE MAY WISH TO INSTALL PARALLEL UNITS TO PREVENT SERVICE INTERRUPTIONS. 4. ASSEMBLY WILL BE OWNED AND MAINTAINED BY PROPERTY OWNER, STARTING AFTER THE INUNE GATE VALVE AT THE PROPERTY LINE OR RIGHT —OF —WAY UNE. 5. COUNTY WILL REQUIRE DEDICATION OF MATERIAL UP TO AND INCLUDING THE INUNE GATE VALVE FROM THE COUNTY'S WATER MAIN. 6. BACKFLOW DEVICE REQUIRES INITIAL CERTIFICATION BY AN APPROVED CERTIFIED TESTER WITH RESULTS AND ANNUAL TEST RESULTS SUBMITTED TO THE COUNTY WATER DEPARTMENT. 7. ALL PLANTING SHALL BE A MINIMUM OF 1.5' FROM THE EDGE OF SLAB, AND SHALL PROVIDE A 3' ACCESS OPENING. 8. THIS ASSEMBLY SHALL BE PAINTED WITH RED EPDXY PAINT. 10. A REDUCED PRESSURE DETECTOR BACKFLOW ASSEMBLY SHALL BE USED WHEN HIGH HAZARDS, AS DEFINED BY AWWA M -14 (e.g.. RISK OF CHEMICAL ADDITION, MEDIC R, ETC.), IXIST. DETECTOR CHECK ASSEMBLY DETAIL NTS REVISED: JULY 2011 Packet Page -2769- 7/26/2011 Item W.B. Packet Page -2770- N m�p w J < O i Z° w a N 3 aa W� O 0 Z S 7 rr aZa Z�+ i d d W a O O U F tow 3 N W O W i 0 Q (zWJ Q w N w -° z N z �ma� K ¢g ¢�JaQw3 Q 0 ¢y� a w o�W° ° O m 00 ° z o - 3x Z� ° Z N 0 w ° W Y 3 W ° Q W W Z O OU J° Z Ma O o Z O ~ J Z � . °S ��iZ� W Y zn UQ Npd'O dW w d 3 U Ome O IyN-j KZd W pda, >U Q�J OOW �p<Y< Q~ W Wpbs WK a ° yNZO mFQF--ENV NO0 a0 m J Z Z 0 0 SW0 ¢ O 0 3 % ZW O M W O'�0(/) 0 N S K 2 U W Nr-fS J Z } �- N 0 F Z W Z Z OUJbb N U Z W _H W W }> O Z ? d 3 i Q O > Or wp� a3oUmz Qj m W y fn wwrnwwa ° �c m� 0 NWN UJNNwQ Jam_II w K O W 0 Z E x v Wn^ W <a z d 0 w o ° � o ono , W w ri rm 3m U w�� o 3 N za Z as z _ w M o Z} O N H J W m i mg w aJ Oz WO E 2 :2 C O m a Q O C UQ ¢ p zb Q � 'NIA Q oaa .Zt °� o- n oo zQ w 0 3N O W F¢ >w az W 0 Q N W H W 1� Z = Y dj QL 0UN Z Z " - O r �3 O J W W �d aun ¢z N W Q M • • C U Q N v N r ro Qfkf / o 'NI N W Ll w 0 ¢ �+ Z W =� 2. > O mg Wm 30 O } W •-- W UQ O Kw `r Oy Op ap W > ZN O r QU O as a O O 0 W Z �'mZ W0 �W mM F- 0 z ma zN NO za 3 ,.3 ,iw j¢W zo) 3 �3 NW m 0 10 W� z O m° -, Z Q o z N <?z > �a �m¢� ° > jw WD�OD o"6� W w aO SUN ~OHO\ �< iR' °W Z °li� �W Npp U W J fJ� yo 3i[I N0Z° W W ' N w WM a 0 W°- z Li ? wwza ° w �= ,W ow e z�3 soar a zw az �o O0w ml< zymjl o Smarm r gy wd� O ?KEW 5 wa 0�W 0 a_z zQOa w w O r �z W �w3 Sao ?Mo CiWW J z J >NUI W N ° c'gap W } zao= 0 0 �SZw W r�W3 Q H �° O m N mMJ Q D wc?G J U S mZ0 z j? O W Z > Z m y2j K a Q a �n �� 0 vI o o 3NIl I.VM- 30- 1HOI2i 0 ` - 80 3NIl ua3doad Z � n rj W -15 REVISED: JANUARY 2009 Packet Page -2770- 7/26/2011 Item 17.B. lloz J,-inr :03SIA3N z °a— izA- ��'zuZi �? 7/26/2011 Item 17.B. Approved Backflow Devices VENDOR I SIZE I MODEL NO. I TYPE I USE Ames / Watts 3/4" - 2" 4006/919 RP Residential or commercial potable 2" 4000B -FP DCDA water locations Watts 3/4" - 2" 909 -009 Series RP Residential or commercial potable 2" - 3" 007 DCDA water locations Wilkins 3/4" - 2" 975 RP Residential or commercial potable 2.5 " -12" 350 DCDA water locations Ames / Watts 2.5" - 10" C -400 / 957 RP Large size meter - potable water for 2" 4000B -FP DCDA commercial or residential applications Watts 2.5" - 10" 909 RP Large size meter - potable water for 2" - 3" 007 DCDA commercial or residential applications Wilkins 2.5" - 10" 375 RP Large size meter - potable water for 2.5 " -12" 350 DCDA commercial or residential applications Ames 3/4" - 2" 40006 -LBV RP Combo services: fire and domestic 2" 4000B -FP DCDA lines Watts 3/4" - 2" 009LF RP Combo services: fire and domestic 2" - 3" 007 DCDA lines Wilkins 3/4" - 2" 975XL (w /OS &Y only) RP Combo services: fire and domestic 2.5 " -12" 350 DCDA lines Ames Colt 2.5" - 10" C -400 (w /OS &Y only) RP Combo services: fire and domestic 2" 3000B DCDA lines Watts 2.5" - 10" 909 (w /OS &Y only) RP Combo services: fire and domestic 2" - 3" 007 DCDA lines Wilkins 2.5" - 10" 375 RP Combo services: fire and domestic 2.5 " -12" 350 DCDA lines Ames Fire Lines - Standard 2" 3000B DCDA Watts Fire Lines - Standard 2" - 3" 007 DCDA Wilkins 2" 950XLTDAF DCDA Fire Lines - Standard Ames Fire Lines - Standard 2.5 " -10" C300 /M300 DCDA Watts Fire Lines - Standard 3" - 10" 709 DCDA Wilkins Fire Lines - Standard 2.5 " -12" 350 DCDA Wilkins q" _ 10" 450 (N- Shape) DCDA Fire Lines - Standard Note: All fire line Backflow Devices shall be UL or FM approved for fire service installation. Above is a small list, others may be used if requirements are met and information is provided Appendix G Packet Page -2772- Rev. 07/2011 7/26/2011 Item 17.13. 68 a Thursday, July 140 2011 • Naples Daily News e e , , ' �, s NOTICE OF INTENT TO CONSIDER RESOLUTION Notice is will hold a publicghearinhgaT esday, July 26, 2011 In the Boardroom, Ind Collier , Ad- ministration Building, Collier County Government Center, 3299 Tamiami Trail East, Naples, Florida' The meeting will begin at 9:00 A.M. The title of the proposed Resolution is as The . , FLORIDAASEX -OFFICIO BOARD THE GOVERNING BOARD OF ITHE RS OF COLLIER COUNTY DIISTR APPROVING AMENDMENTS TO THE COLLIER COUNTY WATER -SEWER DISTRICT'S UTILITIES- STANDARDS MANUAL, WHICH 15 AN INTEGRAL PART. OF COLLIER COUW TY ORDINANCE NO. 200431, KNOWN AS' THE COLLIER COUNT UTILITIES STANDARDS AND PROLE- ' DURES ORDINANCE, WHICH IS CODIFIED IN CHAPTER 134, ARTICLE III OF THE'CODE OF LAWS AND ORDINANCES; PROVIDING FOR A DELAYED EFFECTIVE DATE OF AU- GUST 1, 2011 FOR THE MANUAL Copies of the proposed Resolution are on file With the Clerk to the Boats and are available for inspection. All interested parties are invited to attend and be heard. NOTE: All Persons wishing to speak on any agenda item must - register with the .County administrator prior to presentation of the agenda hem to be addressed. he dividual speakers will be limited to 3 minutes on any item. fie to be A r se indi- vidual to speak on behalf of an organization or group is encouraged. If recognized by the Chairman, a. spokesperson tOF a group or organization maybe allotted 10 minutes to speak on an item. Persons wishing to have written or graphic materials included in the Board agedda packets must submit said material a minimum of 3 weeks' prior to the respe jve public hearing. In any case, written materials intended to - beconsidered yb the Board shall be submitted to the appropriate County staff minimum of seven days prior to the public hearing. All material used in presentations before the Board will become a permanent part of the record Any person who decides to appeal a decision of the Board will need a record of the Proceedings pertaining thereto and therefore, may need to ensure that a verbatim recor of d the proceedings is made, which record includes the testimony and evi- dence upon which the appeal is based. H you are a person with a disability who needs any accommodation in order to par- ticipate in this proceeding; you are entitled, at no cost to you, to the provision of certain assistance. Please contact the .Collier County Facilities Management Depart- ment, located at 3335 Tamiami Trail East, Building W, Naples; Florida 34112, (239) 252 -8380. Assisted listening devices for the hearing impaired are available In the County Commissioners' Office BOARD OF COUNT COMMISSIONERS COLUER COUNT, FLORIDA. _ FRED COYLE, CHAIRMAN DWIGHT E. BROCK, CLERK - By: Ann lennejohn, Deputy Clerk (SEAL) July 14 2n11 N Packet Page -2773-