Agenda 09/25/2012 Item #16A8 9/25/2012 Item 16.A.8. EXECUTIVE SUMMARY Recommendation to declare Fisher Scientific a sole source vendor and request for authorization to purchase a Dionex Ion Chromatogram Capillary System in the amount of $58,270.53 for the Natural Resources Department. OBJECTIVE: The public purpose of this project is to meet operational needs, stay in compliance with regulatory requirements and to realize cost savings while increasing efficiency in the Natural Resource Laboratory. CONSIDERATIONS: The Laboratory Analytical Section within the Natural Resources Department provides laboratory testing services for drinking, waste and environmental water. Data from the Laboratory Analytical Section is utilized in various programs working toward the goals of compliance with Florida Department of Environmental Protection (FDEP) Water and Wastewater permits; Growth Management Plan requirements; existing South Florida Water Management District (SFWMD) contracts for environmental monitoring, all to ensure the health, safety and well-being of the citizens of Collier County. The current method of analyzing samples is completed with a 20 year old spectrophotometer. This machine, which is considered to be obsolete, is able to test one sample, for one parameter (Phosphates, Sulfates, Nitrates, etc), per machine run. This process is very time consuming because each parameter requires a 1.5 hour machine calibration, mixing of reagents, running of the test, and hand recording of the results. Because of the labor intensive requirements of this machine, an analyst can typically process seven samples per day. The results of these tests are highly affected by the concentration of reagents mixed by the analyst and other contaminates in the water, such as salt or sediment. As noted in the attached Business case, the advantages of the recommended instrument over current practices include greater detection sensitivity and analytical accuracy, reduction of human error in transcribing results, and reduced staff time and operating costs. The staff time saved will be used in other areas of concern within the laboratory. These areas include but are not limited to serving as backup analyst and eliminating the need to hire additional personnel. The instrument that staff recommends purchasing is a Dionex ICS-4000 from Fisher Scientific. This device is the only machine on the market that provides simultaneous, reagent free testing of up to 32 samples, for all parameters, without being affected by impurities in the sample. This machine greatly increases the speed of testing by completely automating the testing and notation process, eliminating the time needed for calibration between parameters, and no mixing of hazardous reagents by staff. With this machine the lab can process 128 results in single day, with our current spectrophotometer; would take 18 working days to process the data set. Staff recommends a sole source waiver for this machine because Dionex is the only manufacturer that provides a reagent free platform. This technology will greatly decrease reagent mixing time, variations of results due to reagent mixing irregularities and hazard to Packet Page -2158- 9/25/2012 Item 16.A.8. Collier County employees caused by reagent handling. Staff has negotiated a price of $58,270.35, which is $6,070.74 off the MSRP of$64,341.27. CERTIFICATION BY THE PURCHASING DIRECTOR: The Purchasing staff has contacted 5 other companies that provide lab equipment and agrees that no other company provides comparable equipment. By approval of this Executive Summary, the Purchasing Director certifies that: 1. The item is the only one available that can properly perform the intended function; and 2. The recommended vendor/contractor is the only one ready, willing and able to meet the County's requirement. FISCAL IMPACT: A Purchase Order will be generated in order to procure the Dionex Ion Chromatogram Capillary System from Fisher Scientific. Funds for this purchase were allocated in Fiscal Year 12 in Water Pollution Control Fund 114. The capital cost of the instrument is $58,270.53. The attached Business Case indicates that the recommended instrument will pay for itself in two years and provide an annual cost savings of more than $71,000 by year five. This estimate includes a service contract in the amount of $6,000 after year one from the time of purchase. All maintenance cost shall be included in the service contract. The vendor indicates the useful life of this instrument is ten years. LEGAL CONSIDERATIONS: This item has been reviewed and approved by the County Attorney's Office, is legally sufficient for Board action and only requires a majority vote for °', approval—SRT. GROWTH MANAGEMENT IMPACT: The approval of this purchase is consistent with and furthers the goals, objectives and policies of the Collier County Growth Management Plan. RECOMMENDATION: That the Board of County Commissioners find this vendor as a sole source and approve the purchase and installation of the Dionex Ion Chromatogram Capillary system in the amount of$58,270.53 through the issuance of a County Purchase Order. PREPARED BY: Nosbel Perez, Laboratory Supervisor,Natural Resources Department Attachments: Business Case Fisher Scientific Quote Fisher Scientific Waiver Packet Page-2159- 9/25/2012 Item 16.A.8. COLLIER COUNTY Board of County Commissioners Item Number: 16.A.8. Item Summary: Recommendation to declare Fisher Scientific a sole source vendor and request for authorization to purchase a Dionex Ion Chromatogram Capillary System in the amount of$58,270.53 for the Natural Resources Department. Meeting Date: 9/25/2012 Prepared By Name: PerezNosbel Title: Supervisor-Laboratory,Pollution Control 9/13/2012 8:51:19 AM Submitted by Title: Supervisor-Laboratory,Pollution Control Name: PerezNosbel 9/13/2012 8:51:21 AM Approved By Name: KovenskyKenneth Title: Management/Budget Analyst, Senior,Operations&Regulatory Management Date: 9/13/2012 9:16:14 AM Name: LorenzWilliam Title: Director-CDES Engineering Services,Comprehensive Date: 9/13/2012 9:49:06 AM Name: PuigJudy Title: Operations Analyst, GMD P&R Date: 9/13/2012 10:18:18 AM Name: NorthrupAdam Title: Procurement Strategist,Purchasing Date: 9/13/2012 2:11:59 PM Packet Page-2160- 9/25/2012 Item 16.A.8. Name: MarkiewiczJoanne Title: Manager-Purchasing Acquisition,Purchasing& Gene Date: 9/13/2012 2:34:45 PM Name: WardKelsey Title: Manager-Contracts Administration,Purchasing&Ge Date: 9/14/2012 4:50:34 PM Name: TeachScott Title: Deputy County Attorney,County Attorney Date: 9/17/2012 9:11:01 AM Name: MarcellaJeanne Title: Executive Secretary,Transportation Planning Date: 9/17/2012 10:37:12 AM Name: KlatzkowJeff Title: County Attorney Date: 9/17/2012 10:57:47 AM Name: GreenwaldRandy Title: Management/Budget Analyst,Office of Management&B Date: 9/17/2012 1:14:31 PM Amok Name: OchsLeo Title: County Manager Date: 9/17/2012 2:09:25 PM Amok Packet Page-2161- 9/25/2012 Item 16.A.8. Growth Management Division Natural Resources Department Laboratory Analytical Services Business Case for the Purchase of a Dionex Ion Chromatogram Capillary System in the amount of$58,270.53 Project Background: The parameters that will be analyzed with this instrument are Nitrite, Ortho-Phosphorus, Sulfate, and Fluoride. These parameters are essential in: determining the health of a water body and establishing long term trends; identifying potential sources of pollution; and determining compliance with state drinking water standards and surface and ground water quality criteria. Some of these parameters can produce a wide variety of adverse water quality effects including serious risk to public health and aquatic ecosystems. The current method of analyzing these parameters is through traditional bench chemistry using a spectrophotometer. Bench chemistry is very time consuming as it requires the analyst to mix and handle chemicals directly; attend to each sample individually and hand record results. In addition, the spectrometer can only take one reading at a time while the analyst manually adjusts the machine. Furthermore, the spectrometer can exhibit less sensitivity to background interference such as salt water. The Capillary Ion Chromatograph (IC) instrument is the industry standard for analyzing these parameters because of its ease-of-use and high end performance. This instrument uses patented technology that increases the sensitivity allowing the parameters to be detected at much lower levels. It also eliminates interference from other constituents, such as salt water, which increases the precision of the result. This instrument is also fully automated and can analyze up to 32 samples simultaneously for Nitrite, Ortho- Phosphate, Sulfates and Fluorides providing 128 results in a work day. Currently, an analyst would spend approximately 3 work days on 20 samples of Nitrite, Ortho- Phosphorus, Sulfate and Fluorides. Based on this, the analyst will save approximately 60% of his/her time by using an Ion Chromatograph. This is partly due to the significant decrease in Quality Control samples that would be required by the methodology. Also, results are automatically recorded by the instrument and stored by computer software, thus removing the chance of any Page 1 of 4 Packet Page -2162- 9/25/2012 Item 16.A.8. transcription errors. In addition to saving staff time, this automated process is expected to Alok provide a cost savings of approximately$4,000 a year in just consumables. A five-year cost analysis was performed and is summarized in Table 1. The equipment costs $58,300 and will require a $6,000 per year service contract. We have estimated the fully burdened Personal Services cost of a chemist to perform the analyses at $17,920 per year with annual supplies costing $8,440. This is the Capillary IC alternative. We then compared this to the cost of the current bench chemistry alternative having estimated annual costs of$44,820 for Personal Services and$12,240 for Supplies. Table 1. End of Year: 0 1 2 3 4 5 IC Alternative Equipment Purchase 58,300 0 0 0 0 0 Service Contract 0 0 6,000 6,000 6,000 6,000 Personnel Services 0 17,920 17,920 17,920 17,920 17,920 Supplies 0 8,440 8,440 8,440 8,440 8,440 Total 58,300 26,360 32,360 32,360 32,360 32,360 Cumulative 58,300 84,660 117,020 149,380 181,740 214,100 Bench Chemistry Alternative Alosik Personnel Services 0 44,820 44,820 44,820 44,820 44,820 Supplies 0 12,240 12,240 12,240 12,240 12,240 Total 0 57,060 57,060 57,060 57,060 57,060 Cumulative 0 57,060 114,120 171,180 228,240 285,300 Figure 1. Cost Analysis of purchasing Capillary Ion Chromatograph vs. Current method. Break Even Analysis for Capillary IC Acquisition 300000 IC Alternative F, 250000 c ( Bench Chemistry 200000 _ ..... as 150000 3 E 100000 50000 0 End of 0 1 2 3 4 5 Year Page 2 of 4 Packet Page-2163- 9/25/2012 Item 16.A.8. This investment will have paid for itself in two years and provided a $71,500 cost savings by year 5. (See Figure 1) This compares very favorably with the manufacturer's useful life estimate of 10 years. This instrument is a sole source item due to the patented Chemical Suppression and Membrane Technology(U.S. patents 4,474,664; 4,999,098; 5,248,426; and 5,352,360). Action: To ensure samples are analyzed in a cost effective and efficient manner while continuing to meet the objectives of the Growth Management Plan, contractual obligations to South Florida Water Management District and to stay in compliance with The NELAC Institute (TNI) regulations it is recommended that the Pollution Control Laboratory purchase an Ion Chromatograph. Benefit: • For the clients, this means quicker turn-around times, lower method detection limits, more precise results (CAT Scan vs. X-Ray), and ultimately lower costs. • Replacing out-dated instrumentation with newer and more precise instrumentation. • Increase efficiency of laboratory by reducing the number of samples analyzed by time consuming bench chemistry. • Increased efficiency will allow current staff to increase sample throughput. • Increased efficiency will allow current staff more time to train on other analyses. This will provide bench strength for each analysis allowing the ability to rotate chemists and create a more flexible laboratory schedule for clients. . • Reduces the number of chemicals, calibration standards and other consumables used for analysis, increasing cost effectiveness while maintaining compliance with TNI (The NELAC Institute). Consequence of Not Funding This Item: • Unable to capitalize on greater efficiency and cost savings. • Unable to provide new proven technology that eliminates many problems associated with saline waters. • The potential for increasing workload is jeopardized if this instrument is not funded. If this instrument is not funded, taking on additional monitoring programs or clients will be jeopardized. • This instrument is already 5 years passed its 15 year shelf life. If it breaks down, analyses cannot be completed risking non- compliance existing contracts and loss of data(See Figure 2). Page 3 of 4 Packet Page -2164- 9/25/2012 Item 16.A.8. � cs y ms s. 3 A Figure 2 Page 4 of 4 Packet Page -2165- 9/25/2012 Item 16.A.8. Sales Quotation Fisher Scientific Quote Nbr Creation Date Due Date Page Part of Thermo Fisher Scientific 2212-0154-91 07/30/2012 1 of 3 Payment Terms Delivery Terms FISHER SCIENTIFIC COMPANY LLC 4500 TURNBERRY DRIVE NET 30 DAYS DEST HANOVER PARK IL 60133-5491 Valid To Prepared By 08/29/2012 VIRDEN, ROGER Customer Reference Sales Representative RFQ IC CAPILLARY SYSTEM ROGER VIRDEN W/AUTOSAMPLER PLEASE REFER TO THE QUOTE NUMBER ON ALL CORRESPONDENCE To place an order Ph: 800-766-7000 Fx: 800-926-1166 Submitted To: Customer Account: 158663-003 THANK YOU FOR YOUR INTEREST IN FISHER NOSBEL PEREZ COLLIER COUNTY POLLUTION SCIENTIFIC COMPANY LLC NOSBELPEREZ @COLLIERGOV.NET CONTROL&PREVENTION 3339 TAMIAMI TRL E FOR COMPLETE TERMS AND CONDITIONS VISIT 239-304-4252 STE 304 OUR WEBSITE AT NAPLES FL 34112-5361 www.fishersci.com/salesterms ATTN: NOSBEL PEREZ Nbr Qty UN Catalog Number Description Unit Extended Price Price 1 1 EA NON-CATALOG AS-AP AUTOSAMPLER,BASE CONFIG 13,455.00 13,455.00 Vendor Catalog#074921 COLLIER List Price: 14,950.00 CDC:051 3 EA NON-CATALOG AS-AP 10ML VIAL TRAY 184.50 553.50 Vendor Catalog#074938 COLLIER List Price:205.00 CDC: 051 3 1 PK DX074228 PS VIAL KIT 10ML WCAP BL 100PK 112.50 112.50 Kit,Vial;Thermo Scientific; Dionex; For use with AS-AP Autosamplers; Polystyrene; 10mL;With caps and blue septa Vendor Catalog#074228 This item is being sold as 100 each per pack Original Catalog Number 074228 List Price: 131.25 CDC: 013 4 1 EA NON-CATALOG CHROMELEON 7'WSOW/DESKTOP IC 5,670.00 5,670.00 Vendor Catalog#071800 COLLIER List Price:6,300.00 CDC: 051 5 1 EA NC0316710 ADDITIONAL NEW LICENSE .01 .01 Vendor Catalog#071704 Original Catalog Number 071704 List Price: .01 CDC: 999 6 1 EA NON-CATALOG HP P3005D LASER PRINTER 450.00 450.00 Vendor Catalog#071661 COLLIER Packet Page-2166- 9/25/2012 Item 16.A.8. Sales Quotation Fisher Scientific Part of Thermo Fisher Scientific Quote Nbr Customer Reference Page Lk 2212-0154-91 RFQ IC CAPILLARY SYSTEM 2 of 3 :_- W/AUTOSAMPLER Nbr Qty UN Catalog Number Description Unit Extended Price Price List Price: 500.00 CDC: 051 7 1 EA NON-CATALOG PRINTER INTERFACE CABLE 27.00 27.00 Vendor Catalog#960759 COLLIER List Price: 30.00 CDC: 051 8 1 EA NON-CATALOG dONPAC AS19 CAP COLMN .4X250MM 828.00 828.00 Vendor Catalog#072064 COLLIER List Price:920.00 CDC:051 9 1 EA NON-CATALOG IONPAC AG19 CAP GUARD COLMN 270.00 270.00 Vendor Catalog#072065 COLLIER List Price: 300.00 CDC: 051 10 1 EA NON-CATALOG PROD,CONS,ANION RFIC-EG BUNDLE 3,478.50 3,478.50 Vendor Catalog#072257 COLLIER List Price: 3,865.00 CDC: 051 11 1 EA NON-CATALOG PURIFIED WATER,ION CHROMAT 1L 135.00 135.00 Vendor Catalog#080157 COLLIER List Price: 150.00 CDC: 051 12 1 EA NON-CATALOG BOTTLE CAP ADAPTER 38MM-GL45 72.00 • 72.00 Vendor Catalog#078723 COLLIER List Price: 80.00 CDC: 051 13 1 EA DX056933 SEVEN ANION STANDARD 150ML 99.00 99.00 Standard;Thermo Scientific Dionex; Combined Seven Anion Standard I; For routine anion determinations; Contains: Fluoride,20mg/L; Chloride, 30mg/L; Nitrite, 100mg/L; Bromide, 100mg/L; Nitrate, 100mg/L; Phosphate, 150mg/L;Sulfate, 150mg/L Vendor Catalog#056933 This item is being sold as 1 per each Original Catalog Number 056933 List Price: 110.00 CDC:087 14 1 EA NON-CATALOG ICS-4000 CAPILLARY HPIC SYSTEM 33,120.00 33,120.00 Vendor Catalog#075130 COLLIER List Price: 36,800.00 CDC: 051 15 2 EA NCO266869 POWER CORD US .01 .02 Vendor Catalog#960708 Packet Page -2167- 9/25/2012 Item 16.A.8. Sales Quotation Fisher Scientific Part of Thermo Fisher Scientific Quote Nbr Customer Reference Page 2212-0154-91 RFQ IC CAPILLARY SYSTEM 3 of 3 W/AUTOSAMPLER Nbr Qty UN Catalog Number Description Unit Extended Price Price Original Catalog Number 960708 List Price: .01 CDC: 050 MERCHANDISE TOTAL 58,270.53 NOTES: Returns are subject to manufacturer terms and conditions. We now offer highly competitive financing with low monthly payments. Please contact your local sales representative for more information. Tell us about your recent customer service experience by completing a short survey.This should take no longer than three minutes. Enter the link into your browser and enter the passcode: USA-PGH-CS2 http://survey.medailia.com/fishersci • Packet Page -2168- 9/25/2012 Item 16.A.8. C oti6 ler County Collier County 1,4710Administrative Services Waiver Request Purchasing Instructions Completed waiver requests must be submitted to the department's procurement professional for any amount above $3,000. Purchases above$3000 require three quotes or formal competition. The department must provide justification to Purchase to request consideration to waive the competitive purchasing process and purchase from a single vendor. Waivers of greater than $50,000 will require approval by the Board of County Commissioners 'To:qualify for a waiver select a waiver category, provide an explanation of the-research conducted and the supporting rationale,and acquire the approval signature from your director.Send-the waiver waiver request any research information and contract materials to your purchasing professional in Purchasing: Requester Name: Nosbel Perez Vendor Name: Fisher Scientific Department: Natural Resources Department Item/Service: Dionex ICS-4000 Requisition #(if applicable): Anticipated Cost: $58,270.35 Emergency: Describe the public health or safety issues that requires the immediate product or service(i.e.,The supply of vaccination was completely depleted within hours of delivery to the employee health center;the current vendor will not receive another shipment for 2 weeks). Compatibility/Proprietary(One of a Kind or No Substitute Available): Describe the research completed to determine that there is only one product or service capable of meeting the County's existing conditions and that no other vendor can provide a product,component,or replacement part that may be substituted. Fisher Scientific is the only manufacturer that provides a Reagent Free Ion Chromatography system. Authorized Distributor: Describe the research completed to find similar features and operability,and a letter from the manufacturer naming the single source authorized distributor(s)in the southwest Florida region. A representative from Purchasing and myself contacted 5 different manufacturers of Ion Chromatography systems, none of which provide a Reagent Free Platform. Fisher Scientific is the only distributor of the Dionex ICS-4000. It is a felony to knowingly circumvent a competitive process for commodities or services by fraudulently specifying sole source. Florida Statute 83822(2). Requested by: Date: S/Q 1 f(� - 9 /o ,Z Department Director: > Date: Procurement Professio al Date Packet Page -2169-