Loading...
Agenda 05/13/2013 Item #10E5/14/2013 10.E. EXECUTIVE SUMMARY Recommendation to direct the County Attorney to issue the attached Notice of Default to KPK Management, Inc., assignee of Global Manufacturing Technologies, Inc., relating to a Sublease dated August 15, 1999, of the Immokalee Airport Incubator Building, setting forth that if certain lease violations are not rectified within 30 days of the Notice, that the Airport Authority will terminate the Sublease and, if necessary, pursue its legal remedies, and to grant the Airport Executive Director the authority to work with the County Attorney to terminate the Sublease and pursue legal action, including eviction proceedings, if the defaults are not cured. OBJECTIVE: To require KPK Management, Inc., the present subtenant of the Immokalee Airport Incubator Building under a sublease dated August 15, 1999, to clean up the building, remove all safety hazards, and otherwise fulfill its maintenance requirements, failing which to remove them as the Subtenant. Violations currently include compromised ceiling insulation, broken and stained tiles, missing dry wall, metal shavings in primary office carpet requiring the carpet replacement and other issues listed in the Collier County Airport Authority's January 18, 2012 and January 16, 2013 inspection reports outlining all violations. CONSIDERATIONS: The Global Manufacturing Technologies, Inc. sublease was signed in 1999 for a term 29 years, and later assigned to KPK Management, Inc. Under Article VI (Obligations of Subtenant) section G of the lease, Global Manufacturing Technologies, Inc. "accepts the Subleased Premises at such time as tenant takes occupancy as is in their then condition and without expense to Authority or Collier County, will repair and maintain the Subleased Premises and installations thereon and remove or cause to be removed debris from the surrounding ground to the extent Authority may require." Under Article VIII (Maintenance) section B, sub - section 1 the lease agreement states, "Subtenant shall, without cost to Authority, maintain the Subleased Premises, Common Area subject to Article V, Paragraph E and the furniture and equipment described in Exhibit B and every part thereof in good appearance, repair, and safe condition, consistent with good business practice. Subtenant shall repair all damage to the Subleased Premises caused by its employees patrons, invitees, permitees, contractors, labors, suppliers, etc. or its operation thereon; and shall maintain and repair all improvements thereon including drainage installations, paving, curbs, islands, building and all other improvements." The Authority notified Global Manufacturing Technologies, Inc., of lease violations by issuing inspection reports from the Immokalee Airport Manager on behalf of the Airport Authority on February 19, 2012, and February 4, 2013. Corrections to the issues have not yet been completed. Maintaining clean business practices is a priority for both the Authority and for the Board of County Commissioners and such direction is outlined in the Global Manufacturing Technologies, Inc. lease. FISCAL IMPACT: There is no revenue shortfall as a result of keeping the sub - leases. LEGAL CONSIDERATIONS: This item has been reviewed by the County Attorney, is legally sufficient, and requires majority support for approval. -JAK. Packet Page -97- 5/14/2013 10. E. RECOMMENDATION: That the Board of County Commissioner, acting as the Collier County Airport Authority (1) directs the County Attorney to issue the attached Notice of Default to KPK Management, Inc., assignee of Global Manufacturing Technologies, Inc., relating to a Sublease dated August 15, 1999, of the Immokalee Airport Incubator Building, setting forth that if certain lease violations are not rectified within 30 days of the Notice, that the Airport Authority will terminate the Sublease and, if necessary, pursue its legal remedies, and (2) grants the Airport Executive Director the authority to work with the County Attorney to terminate the Sublease and pursue legal action, including eviction proceedings, if the defaults are not cured. Prepared by: Commissioner Tom Henning, District 3 2 Packet Page -98- 5/14/2013 10.E. COLLIER COUNTY Board of County Commissioners Item Number: 10.10.E. Item Summary: Recommendation to direct the County Attorney to issue the attached Notice of Default to KPK Management, Inc., assignee of Global Manufacturing Technologies, Inc., relating to a Sublease dated August 15, 1999, of the Immokalee Airport Incubator Building, setting forth that if certain lease violations are not rectified within 30 days of the Notice, that the Airport Authority will terminate the Sublease and, if necessary, pursue its legal remedies, - and to grant the Airport Executive Director the authority to work with the County Attorney to terminate the Sublease and pursue legal action, including eviction proceedings, if the defaults are not cured. Meeting Date: 5/14/2013 Prepared By Name: SmithCamden Title: Executive Aide to the BCC 5/2/2013 5:49:39 PM Submitted by Title: Executive Aide to the BCC Name: SmithCamden 5/2/2013 5:49:40 PM Approved By Name: SheffieldMichael Title: Manager- Business Operations, CMO Date: 5/6/2013 11:26:21 AM Name: KlatzkowJeff Title: County Attorney Date: 5/6/2013 11:48:00 AM Name: KlatzkowJeff Title: County Attorney Packet Page -99- Date: 5/6/2013 1:48:41 PM Name: OchsLeo Title: County Manager Date: 5/6/2013 4:55:28 PM Packet Page -100- 5/14/2013 10. E. 5/14/2013 10.E. Office of the County Attorney Jeffrey A. Klatzkow Deputy County Attorney • Scott R. Teach Managing Assistant County Attorney • Heidi F. Ashton- Cicko* *Board Certified City. County and Local Government Law Assistant County Attorneys • Colleen M. Greene Ke -,yin L. Noell Emily R. Pepin Jennifer B. White .Jeff E. Wright* By Hand Delivery May 15, 2013 KPK Management, Inc. As assignee from Global Manufacturing Technologies, Inc. Sublease of Manufacturing Incubator Building Immokalee Regional Airport Attn: Lawrence M. Fox Re: Notice of Material Breach of Sublease Agreement Dear Mr. Fox: This letter is in furtherance of action taken by the Collier County Airport Authority on May 14, 2013. In February 2012 and February 2013, KPK Management Inc. (hereinafter "KPK ") representatives were notified of numerous sublease violations following inspections that occurred by Collier County Airport Authority representatives on January 18, 2012 and January 16, 2013 respectively. The violations include the following: compromised ceiling insulation, broken and stained tiles, missing dry wall, metal shavings in the primary office carpet requiring replacement and other issues listed in the inspection reports previously provided to KPK. The Sublease Agreement, dated August 15, 1999, between Global Manufacturing Inc. and Collier County Airport Authority, is clear that the subtenant KPK Management, Inc. has the ongoing duty to maintain and repair the leased facility and premises. Article VI (Obligations of Subtenant) section G of the Sublease Agreement states in pertinent part: "Subtenant accepts the Subleased Premises at such time as tenant takes occupancy "as is" in their then condition and, without expense to Authority or Collier County, will repair and maintain the Subleased Premises and installations thereon..." . Article VIII (Maintenance) section B, sub - section 1 states in pertinent part: "Subtenant shall, without cost to Authority, maintain the Subleased Premises, Common Area subject to Article V, Paragraph E and the furniture and equipment described in Exhibit B and every part thereof in good appearance, repair, and safe condition, consistent with good business practice. Subtenant shall repair all damage to the Subleased Premises caused by its employees, patrons, invitees, permitees, contractors, labors, suppliers, etc. or its operation thereon; and shall 3299 East Tamiami Trail, Suite 800 • Naples Florida 34112 -5749 • (239) 252-8400 • FAX: (239) 774-0225 Packet Page -101- 5/14/2013 10. E. maintain and repair all improvements thereon including drainage installations, paving, curbs, islands, building and all other improvements." Be advised that this correspondence shall serve as formal notice that KPK has failed to comply with material condition(s) of the Sublease Agreement and is therefore in breach of the same. Pursuant to Article XX of the Sublease Agreement, be advised that if said breach shall continue for thirty (30) days from receipt of this written notice, said failure shall constitute a material default of the Sublease Agreement, authorizing the Airport Authority to terminate the Sublease Agreement and, if necessary, pursue any and all legal remedies. Be governed accordingly: Jeffrey A. Klatzkow County Attorney cc: Chris Curry, Executive Director, Collier County Airport Authority Thomas Vergo, Manager, Collier County Airport Authority 3299 East Tamiami Trail, Suite 800 • Naples Florida 34112 -4902 • (239) 252-8400 • FAX: (239) 52-6300 Packet Page -102- 5/14/2013 10. E. Photo Documentation of Immokalee Airport Rental Damage Global Manufacturing Technologies, Inc Facility Damage Full photo documentation is in the Airport Authority's February 4, 2013 Inspection Report Packet Page -103- Examples of Other Damage to Property 5/14/2013 10.E. Above: the must be replaced - damaged Above: Unapproved lock on door Above: fork lift provided by airport is running but damaged and being stored outside Above: bathroom the ruined, must be replaces' Packet Page -104- Ceiling insulation falling down in many bays except bays 2 and 3 5/14/2013 10.E. Additional photos in the FEwo mut r ����r�•.���n Report by the Authority N�+ Packet Page -105- Above: drywall and coping damage Below: fire alarm horn and strobe cracked Above: drywall missing around door Below: electric panel faded / schedules incorrect gE G�yP lupoop� 5/14/2013 10.E. o COLLIER COUNTY AIRPORT AUTHORITY 2005 Mainsail Drive, Suite 1 Naples, Fl, 34114 -8955 (239) 642 -7878 Fax (239) 394 -3515 www.collieraviation.com Created: February 18, 2012 Updated: March 1, 2012 Mr. Larry Fox Global Manufacturing Inc. 160 Airpark Blvd. Immokalee, FL 34142 Mr. Fox, The Management Staff at the Immokalee Regional Airport conducted the annual Compliance and Safety Inspections of your leased building in accordance to the provisions of Article XXXI of your sub -lease agreement on Wednesday, January 18, 2012. In attendance was Leo Rodgers (Immokalee Fire District Fire Marshal), Chris Wiggins (Immokalee Airport Operations), myself, Thomas Vergo (Airport Manger of Immokalee Regional Airport), and you, Larry Fox. The inspection was conducted to assess the overall condition and maintenance of the facility in compliance with Article VIII Sections B1 & B2 of the original sublease dated and executed on August 15, 1999. Your facility is used as a manufacturing incubator support facility with your company leasing the entire facility and sub - leasing individual bays to small manufacturing companies not owned or operated by your company. Your facility also has been furnished with furniture and equipment that has been provided by the Airport for the use of the tenants of the building. The condition of these items was also evaluated during this inspection. During the inspection, Airport Staff and/or Fire Marshal noted the following non - compliance issues as outlined in the approved Airport Rules and Regulations, your signed lease, and /or National Fire Protection Codes. For ease of reporting, the condition reporting and compliance issues have been separated by bay and/or office spaces below. Lobby/Reception Area The overall condition of the lobby area was rated as in good condition. There were cobwebs in many of the windows and the furniture dusty. The carpet seemed in good repair with minor spotting and the entry doors operated smoothly during both the open and closing cycles. The access key located in the Fire Department Key Box on the exterior of the building was verified for operation. The below items were found to need attention/repair: Exit light above front entry door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 —Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above front entry door. Marco Island Executive Airport 2005 Mainsail Drive, Suite 1 Naples, FL 34114 -8955 239.394.3355 239.642.5427 Fax Immokalee Regional Airport 165 Airpark Boulevard Immokalee, FL 34142 239.657.9003 23^ .. . ­1 r-.. Packet Page -107- Everglades Park 650 E.C. Airpark Road Everglades City, FL 34139 239.695.2778 239.695.3558 Fax 5/14/2013 10.E. Inspection Report: Global Manufacturing Technologies, Inc. Page 2 Conference Room The conference room is located directly off the lobby /reception area. It was in good condition overall and have a large conference table with chairs. It appears the conference room was being used for both temporary and long -term storage of miscellaneous items. On the east wall, there is a dry-erase marker board that is rated in good condition. The below items were found to need attention/repair: • The carpeting is rippling in many areas. This can pose a tripping hazard for the occupants and customers who may use the facility. o Recommended Action: Repair the ripples in the carpet to prevent a tripping hazard. • In the north -east corner of the conference room, 2 ceiling tiles are heavily stained from an unknown cause (Identified on previous inspection report from 7/8/2010). o Recommended Action: Verify the reason for the staining and replace the ceiling tiles. Adjoining Office (North of Reception Area) The flooring looked to be in good condition and walls free of marks or holes. Although there were no compliance or safety issues found in this area, it is recommended that the cobwebs in the windows and screens in this area be cleaned. Office ( #104) and Hallway This office area has the ability to be closed off and locked with the door functioning as designed. This space is directly across from the shared men's and women's bathrooms. In the hallway area is a fuse and fire alarm panel. The fire alarm panel is the central panel for the entire building and had been recently serviced and inspected by a fire alarm contractor. The below items were found to need attention/repair: The fire alarm panel was showing a trouble code /signal. The tenant stated to the Fire Marshal that the cause of the code is unknown at this time. o Recommended Action: Verify the reason for the trouble code and have affected component(s) repaired/replaced and operating in accordance with NFPA 72. Tool Room #108 (East of Office #104) The below items were found to need attention/repair: • Ceiling insulation is torn and falling down from ceiling. o Recommended Action: Repair insulation back to original position. If required, replace insulation. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -108- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 3 • insulation over overhead rollup door falling down o Recommended Action: Repair and secure insulation back to its original position • Unprotected penetration in Fire /Smoke Barrier. o Recommended Action: Close penetration in accordance with proper fire codes. Receiving/Storage #111A This room appears to be used for the storage of minor materials. The flooring in this room is in poor condition and will need to be replaced. The below items were found to need attention/repair: Rear exit door lock and bottom threshold have been removed. o Recommended Action: Replace /reinstall door lock and bottom threshold. • Sliding lock/hasp installed on rear exit door not in accordance with NFPA 101. o Recommended Action.: Remove non- approved door hardware from door. • Electrical service panel blocked with boxes and shelves o Recommended Action: Remove boxes and shelving from in front of electrical service panel and maintain a clearance of 3 feet in front of panel. • Vinyl flooring is chipped up and scratched due to items being dragged over flooring and due to the removal of the bottom threshold of the east exterior door. o Replace flooring as needed to make a uniform floor for both aesthetics and safety. Calibration Lair #111 This room is overall in good condition with light wear. All overhead lighting is working and in good order and repair. There is light storage of items and boxes in this room. The below items were found to need attention/repair: • Exit light above entry door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 —Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. Unit A (Bay #1) This bay has numerous large machines operating within. The overall condition of this unit was in good condition. The below items were found to need attention/repair: Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -109- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 4 Emergency light does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency light. Unit B (Bay #2) This bay has extensive electrical cords and outlets installed in an unapproved manner. There are metal shavings accumulating around the machinery. The electrical panel has knockouts missing and spaces without blanks between the breakers. The below items were found to need attention/repair: • Wiring going to various machines is either undersized or not approved for installation in the manner installed. Tenant was present to point our discrepancies at time of inspection and various issues were identified. o Recommended Action: Replace wiring to machines with wire of adequate size and type per the manufacturer's recommendations and local electrical codes. • Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. • Electrical panel has missing blanks between breakers o Recommended Action: Install blanks between breakers in accordance with NFPA 70 National Electrical Code. Unit C (Bay #3) This bay has storage of various items and overall in good, working condition. The below items were found to need attention/repair: • Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. Unit D (Bay #4) The below items were found to need attention/repair: * Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.557.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -110- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 5 • Ceiling insulation is torn and falling down from ceiling (Identified on previous inspection report from 7/8/2010). o Recommended Action: Repair insulation back to original position. If required, replace insulation. • Relocatable power tap outlet improperly wired into building as part of building wiring. o Recommended Action: Remove relocatable power tap from building wiring and only use as designed. • Electrical panel has missing blanks between breakers. o Recommended Action: Install blanks between breakers in accordance with NFPA 70 National Electrical Code. * Thermostat for air conditioning is broken. o Recommended Action: Replace thermostat. Unit D (Bay #5) This bay was in good condition overall with minimal issues. The below items were found to need attention/repair: Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. • Breaker box near ceiling is missing a safety .cover o Recommended Action: Install safety cover on breaker box located near ceiling in accordance with NFPA 70 National Electric Code. • Junction box is missing cover o Recommended Action: Install junction box cover in accordance with NFPA 70 National Electric Code. Unit E (Bay #6) The power to this unit was turned off so overall lighting condition was not able to be checked. Lighting fixtures looked to be in good repair and condition. There is minor damage to the fire wall that needs to be addressed. The below items were found to need attention/repair: • Exit light above door is missing and in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13. o Recommended Action: Replace emergency exit sign above door. Both emergency lights do not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency lights. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -111- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 6 • Electrical panel has missing blanks between breakers. o Recommended Action: Install blanks between breakers in accordance with NFPA 70 National. Electrical Code. • Thermostat for air conditioning broken. o Recommended Action: Replace thermostat. • Sliding lock/hasp installed on rear exit door not in accordance with NFPA 101. o Recommended Action: Remove non - approved door hardware from door. Unit F & G (Bay #7 & #8) This bay was not occupied at the time of inspection but the overhead lighting looks to be in excellent condition. The power was turned off to this unit at the time of inspection so the functionality of the overhead lighting was unable to be verified. The below items were found to need attention/repair: • Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. • Emergency light is missing in Bay #8 and needs to be installed accordance with NFPA 101 14.3 - Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Replace emergency light. • Electrical panel has missing blanks between breakers in both bays. o Recommended Action: Install blanks between breakers in accordance with NFPA 70 National Electrical Code. • Sliding lock/hasp installed on rear exit door not in accordance with NFPA 101. o Recommended Action: Remove non - approved door hardware from door. • Rollup door cover missing (Bay #8) o Recommended Action: Reinstall rollup door cover to operate as designed. Unit H & I (Bay #9 & 410) This bay is subleased to Salazar Machine and Steel. It is a combined bay with 2000 S.F. of continuous space. There is an accumulation of cobwebs in the ceiling but the overhead lighting was in good repair and all worked. The below items were found to need attention/repair: Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1. 14.13. o Recommended Action: Repair /replace emergency exit sign above door. Marco island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -112- 5/14/2013 10.E. Inspection Report: Global Manufacturing Technologies, Inc. Page 7 • Penetrations/holes in Fire /Smoke Harrier. o Recommended Action: Repair damaged sections of the fire walls in accordance with fire and building codes. • Electrical Panel is missing screws o Recommended Action: Install screws to hold panel cover flush with wall. • Ceiling insulation is torn and falling down from ceiling. o Recommended Action: Repair insulation back to original position. If required, replace insulation. • Outlet box is loose and hanging from wall by conduit (Identified on previous inspection report from 7/8/2010). o Recommended Action: Secure outlet box to wall. • Exterior of bay door opening has sheet metal damage from collision with an object or vehicle (Identified on previous inspection report from 7/8/2010). o Recommended Action: Repair or replace the metal as required. • Door handle cut off of exterior door. o Recommended Action: Replace door handle to function as required. Unit J (Bay #I1) This bay is also subleased to Salazar Machine and Steel and is showing signs of overuse. There is wall damage to the western wall of the building that has been left unrepaired. The tenant has installed a shed within the premises that the Fire Marshal wrote up as "work done without a permit." The unit's overhead lighting was in working order with all bulbs and fixtures working as designed. The below items were found to need attention/repair: • Exit light above door does not illuminate on battery power when manually tested in accordance with NFPA 101 14.3 — Emergency lighting must be maintained and tested in accordance to NFPA 1, 14.13 o Recommended Action: Repair /replace emergency exit sign above door. • Penetrations/holes in Fire /Smoke Barrier in multiple locations (Identified on previous inspection report from 7/8/2010). o Recommended Action: Repair damaged sections of the fire walls in accordance with fire and building codes. • Ceiling insulation section is missing from inside unit. o Recommended Action: Repair insulation back to original position. If required, replace insulation. • Electrical panel has missing blanks between breakers. o Recommended Action: Install blanks between breakers in accordance with NFPA 70 National Electrical Code. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -113- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 8 • Thermostat for air conditioning is broken. o Recommended Action: Replace thermostat. Exterior of Building In accordance with the signed and approved lease, the exterior area of the building to include the lighting and pavement is the sole responsibility of the subtenant, Global Manufacturing Technologies, Inc. The general condition of the rear of the building is poor with trash, debris, metal, wood, vegetation, and equipment scattered around. The inspection staff conducted a detailed inspection of the exterior of the building and noted the following items: • Pavement markings such as parking spaces, stop bars, and safety lines are faded and/or missing as shown on building plans. o Recommended Action: schedule parking area to be restriped • Handicap signage is missing and other signage fading o Recommended Action: Replace missing and faded signs as required • At the rear of the building, debris have been allowed to accumulate in the paved common area. There are weeds and vegetation growing inside the dumpster enclosure and inside stacked pallets near the enclosure. o Recommended Action: Remove debris from rear of building to allow landscaping contractor to safely service the property on a weekly basis. • A white, unregistered box truck and red pickup truck with expired registration are being stored behind the building. Airport Rules and Regulations, Section 6.06b: "No vehicle shall remain in any parking facility on the Airport for more than forty -five (45) consecutive days. o Recommended Action: Vehicles need to be removed from the facility or registered or registered and parked within vehicle parking areas. • Vegetation is growing in the rain gutters on the southeast corner of the building. o Recommended Action: Remove vegetation and ensure gutters are clear of debris. • Metal racks and supplies blocking truck pallet lift. o Recommended Action: Remove and relocate items to not impact the truck lift. Lift is a common use item that must remain clear and usable from both directions. • Items are being stored in dumpster enclosure and dumpster is sitting outside of enclosure. on pavement. o Recommended Action: Relocate dumpster back into fenced enclosure. • Rear fire /vehicle lane is being blocked by steel barricades during night and misc. supplies and items are being stored within the 2 -way lane. o Recommended Action: Remove items from within 2 -way fire lane and cease the usage of the steel barricades at night. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -114- 5/14/2013 10. E. Inspection Report: Global Manufacturing Technologies, Inc. Page 9 * Condenser unit enclosures are bent; wiring damaged, and has paint overspray on enclosures. o Recommended Action: Do not allow tenants to use condenser units as work benches and need to have system serviced. Repair the broken electrical fixtures and conduits to meet electrical safety codes. • Front and rear bay doors paint is fading o Recommended Action: Repaint doors and re- number sometime in the future. • Areas of metal panels outside of bay doors in rear are discolored. o Recommended Action: Degrease /clean metal panels Common Use Equipment and Furniture An inspection was conducted on the common use equipment that belongs to the Authority that is positioned over at this particular building. All the office furniture was rated to be in good condition and seemed to be wearing appropriately according to its time in service. The forklift however is currently not working and Airport staff has not seen it in operation for at least the past 8 months. It is believed that the forklift has been out of service for longer than that based off of yearly inventory reports that the County conducts annually. In keeping with the requirements of your lease, you will need. to repair the forklift to operational status. It is a common use item that is required to be maintained and repaired in a timely manner. A follow -up inspection of your leased building is scheduled for Friday, April 20, 2012 between the hours of 9 :00am and 4:00pm. This follow -up inspection will be conducted to verify that the above non - compliance issues have been resolved. You are requested to be in attendance at this follow -up inspection due to the nature of your operation. Airport Management has coordinated with the Immokalee Fire District Fire Marshal, Leo Rodgers to conduct both follow -up inspections at the same time for your continence. The goal of the Airport Management and Staff is to run a safe, efficient, and friendly Airport for all of our customers. If you have any questions or concerns about your inspection results or any other items in the now or in the future, please feel free to contact the Airport at 239 -657 -9003. Sincerely, Thomas Vergo Airport Manager Immokalee Regional Airport Cc: Chris Currv, CCAA Executive .Director Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -115- Friday February 3, 2012 Global Manufacturing 160 AIRPARK BLVD 1 IMMOKALEE, FL 34142 Immokalee Fire Control District 502 E New Market RD IMMOKALEE, P% 34142 Violation Notice R An inspection of your facility on Wednesday January 18, 2012 revealed the violations listed below. ORDER TO COMPLY: Since these conditions are contrary to law, you must correct them upon receipt of this notice. An inspection to determine compliance with this Notice will be conducted on Friday March 2, 2012 at 15:18:13 If you fail to comply with this notice before the reinspection date listed, you may be liable for the penalties provided for by law for such violations. Violation Code Article Division Page Count 433 Fire Alarm not maintained NFPA 72 0 0 Fire Alarm Panel has trouble signal 347 Emergency lighting out of service NFPA 101 14.13 136 0 Emergency Lighting must be maintained and tested in accordance to NFPA 1, 14.13. Exit sign above front door. Lab, Exit Sign Bay 1, Bay 5 445 Penatrations not sealed NFPA 12.7.5.1 78 0 323 Door not equipped Approved exit hardware ----------- -- NFPA 101 0 0 512 Service panel obs-t-ucted NFPA 70 0 0 513 Electrical panel/junction boxes open NFPA 1 11.1.2 51 0 All appliances, fixtures, equipment or wiring shall be installed and maintained in accordance to NFPA 70 National Electric Code. Panel F114 Knock outs missing Knock outs missing in i-box Blanks Missing in Panel 115-208 Bay 5 and 116 Bay 6, Bay 7, Bay 8 and Bayll Dead Front missing on breaker box Bay 5 512.1 Electrical panel not labeled NFPA 1 11.1.2 0 0 1 Bay 11 02103/2012 15:18 Page Packet Page -116- Friday February 3, 2012 Global Manufacturing 160 AIRPARK BLVD 1 im,40KALEE, FL 34142 I=okalee Fire Control District 502 E New Market RD II�RORALEE, FL 34142 violation Notice R U E 515 Building wiring and distribution system unsafe NFPA 70 11.1.3 51 0 Permanent wiring shall be installed and maintained in accordance with NFPA 70, National Electrical Code. J-box and conduit not secured-Salazar Welding 634 Work done without permit 0 0 Shed inside Bay 11 517.1 Improper Use of Relocatable Power Taps NFPA 1 11.1.6 65 0 11.1.6 Relocatable Power Taps. 11.1.6.1 Relocatable power taps shall be of the polarized or grounded type with .)vercurrent, protection and shall be listed. 11.1.6.2 The relocatable power taps shall be directly connected to a permanently installed receptacle. 11.1.6.3 Relocatable power tap cords shall not extend through walls, ceilings, or floors; under doors or floor coverings; or be subject to environmental or physical damage. ------------ 123 Accumulation: Wood, Metal shavings, Dust FFPC 0 0 RODGERS, Inspector 02/103/2012 15:18 Occupant/Owner Packet Page -117- Pace 2 IA A 10%^ A Packet Page -118- 10.E. r IA A lf1%^A n I O. C. Packet Page -119- 14 AInn4 Packet Page -120- 10.E. R11ai,?nl Packet Page -121- 10. E. Packet Page -122- 10. E. �l C C /o1 A /n n,4 Packet Page -123- 10. E. 5/14/2013 10. E. Packet Page -124- I TT %h 5/14/2013 10. E. Packet Page -125- 5/14/2013 10. E. k e5 £ F � u� rz�ea� M k e5 £ u� rz�ea� t • h, 5/14/2013 10.E. Packet Page -127- Packet Page -128- 10. E. Packet Page -129- 10. E. Packet Page -130- 10.E. �ilai ,)nl,i in F Packet Page -131- 5/14/2013 10. E. Packet Page -132- G/-1 A P)f) -1'2 10. E. Packet Page -133- Packet Page -134- 10.E. Packet Page -135- 10.E. r-i1 A1001 '� 10.E. Packet Page -137- r u A 1� ^A Packet Page -138- 10.E. r,11A /')nl'I 10. E. Packet Page -139- MAP% 5/14/201310.E. COLLIER COUNTY AIRPORT AUTHORITY 2005 Mainsail Drive, Suite 1 Naples, FL 34114-8955 C239) 642-7878 Fax (239) 394-3515 www.collieraviation.com March 11. '2' 0 13 Mr. Larry Fox KPK Management, Inc. Z__ 160 Airpark Blvd. Immokalee, FL 34142 Mr. Fox., The Airport Management Staff and Immokalee Fire Marshal attempted to conduct the scheduled follow up inspection of your leased facility at 160 Airpark Blvd. on Wednesday. February 27. 2013 at 1:00pm. We were met by Ronald Gills who notified the inspection team that you were not onsite and that none of the compliance issues had been addressed with the exception of- 0 Improper storage of oil in open 5- gallon pails and unmarked containers. o Majority of improperly stored oil has been disposed of by the tenant but no disposal records were on site and some residual oil still existed in buckets inside/outside rear storage shed. • Clean out located at south end of building broken o Replaced by Airport Staff on 1/29/2013 • Electrical tie-in box located at front of building not on pad (safety issue) o Repaired by Airport Staff on 1,129/2013 To help ensure the remaining, items are completed within a timely manner, you will need to produce a repair schedule dictating how and when you plan to repair each of the indicated discrepancies. This schedule is due within 10 days of receipt of this letter to my office located at the Immokalee Airport General Aviation Building (165 Airpark Blvd). The proposed schedule \Nril] be reviewed by zn - Airport Management and upon approval will be implemented. Follow-up inspections of your leased facility will be scheduled based on your proposed repair schedule. The goal of the Airport Management and Staff is to run a safe, efficient, and friendly Airport for all of our customers. If you have any questions or concerns about this letter or any other items now or in the future, please feel free to contact the Airport at 239-657-9003. Sincere]v. Thomas Vergo Airport Manager C_ Immokalee Regional Airport Cc: Chris Currv. CCAA Executive Director Attachment: 2013 Lease Inspection Results Marco island Executive Airport 2005 Mainsail Drive, Suite I Naples, FL 34114-8955 239.3943355 239.642.5427 Fax Immokalee Regional Airport 165 Airpark Boulevard Immokalee, FL 34142 239.657.9003 Packet Page -140- Everglades Park 650 E.C. Airpark Road Everglades City, FL 34139 239.695.2778 239.695.3558 Fax February 4, 201 Mr, Larry Fox KPK Management. Inc. 160 Airpark Blvd. Immokalee, FL 34142 Mr. Fox, COLLIER COUNTY AIRPORT AUTHORITY 2005 Mainsail Drive, Suite I Naples, FL 34114-8955 (239) 642-7678 Fax (239) 394-3515 5/14/2013 10.E. I tie Management Staff at the Immokalee Regional Airport conducted the annual Compliance and Safety Inspections of your leased building in accordance to the provisions of Article XXXI of your sub-lease agreement on Wednesday. Januai-,y 16. 2013. In attendance was Leo Rodgers (Immokalee Fire District Fire Nlarshal). Chris Wiggins (Immokalee Airport Operations). myself. Thomas Vergo (Airport Manger of Immokalee Regional Airport), Chris Curry (Executive Director - Collier County Airport Authority) and your designee. Ronald Gills. The inspection was conducted to assess the overall condition and maintenance of the facility, in compliance with Article VIII Sections A, 131.. & B-1 of the original sublease dated and executed on August 15, 1999. Urpon arrival at 9:30arri at your facility to conduct your scheduled inspection. the inspection team was notified by Ron Gills that you were not onsite and the building was not ready for Inspection. I.JDon contact with you itv,.,as requested that the Inspection Team come back a few hours later to inspect the premises. All parties involved agreed. and your inspection time was moved to approx. 1:00pm the same day. Your facility is used as a manufacturing incubator support facility with your company leasing the entire facility and sub-leasing individual bays to small manufacturing companies not owned or operated by your company. Your facility also has been furnished w=ith furniture and equipment that has been provided by the Airport for the use of the tenants of the building. The condition of these items was also evaluated during this inspection. The last inspection of this facility took place Wednesday, January 18. 2-0121 and you were given a year to brinL, the building into full compliance as the amount of non-compliant and maintenance items ryas substantial and assurance was given to Airport Management that repairs would be gradually completed. To date, some repairs have not been completed from the past inspection. During the inspection. Airport Staff andior Fire Marshal noted the following non - compliance issues as outlined in the approved Airport Rules and Regulations. your sigL_ ned lease. andJor National Fire - Protection Codes. For ease of reporting- the condition reporting and compliance issues have been separated by bay andlor office spaces beloA-. Marco island Executive Airport 2005 Mainsail Drive. Suite 1 Naples, Fl. 34114-9955 239.394.3355 239,642.5427 Fax tmmokale,e Regional Airport 165 Airpark Boulevard Immokalee, FL 34142 239.657.9003 239,657.9191 Fax Packet Page -141- Everglades Park 650 E.C. Airpark Road Everglades City, Fl, 34139 239,695.2778 239,695-4558 Fax 5/14/2013 10.E. Inspection Report: KPK Management Inc. Page 2 Front Entrance — Exterior The front entrance overall was in good condition with clean and clear windows, fully operating doors, and no physical issues. The night prior to the inspection, an Airport representative noted that many of the front exterior lights were not working. Their locations were as follows: I light over 'I v door -411. 1 light over door #9. 1 light over 43. 1 light over door 41, -3 lights over front entrance sign. The entrance door. and 1 116, out at the Immokalee Manufacturing and Technology Center area is covered in brick pavers and they are showing signs of mildew growth so the recommendation would be to have them cleaned. Lobby/Reception Area The overall condition of the lobby area was rated as in good condition. The carpet seemed in fair repair with minor spotting, rippling and a fair amount of wear. It appear-, that the lessee had the carpets cleaned during the previous year. it is recommended that the carpet be replaced prior to the next yearly compliance inspection due to its age enu re verified for proper ,e and wear. The -y doors we operation and operated smoothly during both open and closing cycles. The access key located in the Fire Department Key Box on the exterior of the building was verified for operation, The below items were found to need attention/repair: Conference Room The conference room is located directly off the lobby/reception area. it was in good condition overall and have a large conference table with chairs. On the east wall, there is a dry-erase marker board that is rated in good condition. The below items were found to need attention!repair: The carpeting rippling; cc s 1 ing in many areas, This can pose a tripping hazard for the o upant. and customers who may use the facility. o Recommended Action: Replace rippling carpet when lobby carpet is replaced, • The walls in the conference room have many nicks and scratches as part of normal wear and scar of conference room. o Recommended Action: Paint any affected walls as part of normal maintenance. Business Services Office (North of Reception Area) The flooring looked w) be in good condition and walls free of marks or holes. The lighting was bright and operational. The cabinets and countertops are in good condition. The below items were found to need atientionfrepair: 2 ceiling tiles have comers missini, o Recommended Action: Replace ceiling tiles with comparable replacements. Marco island Executive Airport immokalee Regional Airport 20D5 Mainsail Drive, Suite 1 165 Airpark Boulevard Naples, FL 341!4-8955 immokalee, FL 34142 239.657.9003 239.642.5427 Fax 239.657,9191 Fax Everglades Park 650 E.C. Airpark Road Everglades City, FL 34139 239.695.2779 239.695.3559 Fax Packet Page -142- 5/14/2013 10.E. inspection Report: KPK Management Inc. Page 3 Office (#104) and Hallway This office area has the ability to be closed off and locked with the door functioning as designed. This space is directly across from the shared men's and women's bathrooms. In the hallway area is a fuse and fire alarm panel. The fire alarTri panel is the central panel for the entire building and had been recently serviced and inspected by a fire alarm contractor. The below items were found to need attention,1'repair: 0 Office has metal shavings covering carpet o Recommended Action: Clean metal shavings from carpet as part of normal routine maintenance of space. The breaker lock for the building's fire alarm panel is missing inside breaker panel next to fire alarm panel, o Recommended Action: Install breaker lock in accordance with NFPA 7/2. 0 Ceilina the falling down near air conditioner register in Men's Bathroom o Recommended Action: Support air conditioner register and replace ceiling tile (it* necessam1 to prevent the from failing in the future. • Ceilinu tile is stained and faucet is not working, in women*s bathroom. c, Recommended Action- Replace the ceiling the with a comparable replacement and service sink faucet to work as designed. • W'ater lountain sprays a 2 foot stream cif water and soaks the adjoining wall during use. o Recommended Action: Adjust water pressure to prevent water from spraying on,%vall and ensure that fountain is operating as designed. Tool Room #108 The below items were found to need attention /repair: Ceilinu. insulation is tom and falling down from ceiling (Identified on previous inspection report from, 3/1.,2012). o Recommended Action- Repair insulation back to original position and installation. If required. replace insulation. • Insulation over overhead rollup door failing down (Identified on previous inspection report frorn 3/1:'21112). o Recommended Action: Repair and secure insulation back to its original position, If required. replace insulation. Marco island Executive Airport Immokalee Regional Airport Everglades Park 1005 Mainsail Drive, Suitf, 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 Immokalee, FL 34142 Everglades City, FL 34139 239,394.3355 239.657.9003 239.695.2778 239,642.5427 Fax 239:657.9191 Fax 239.695-3558 Fax Packet Page -143- 5/14/2013 10. E. inspection Report: KPK management Inc. Page 4 0 Tape around fresh air intake for air conditioner is not attached- o Recommended Action: Reattach tape to seal around fresh air intake pipe. • Tile floor and shower are stained and dirty o Recommended Action: Shower and bathroom floor need to be cleaned and maintained as part of regular maintenance. 0 Electrical panel circuit schedule is faded and needs updated circuit listing. o Recommended Action: Reprint, update, and replace faded panel circuit schedule in accordance with NFPA 70. 0 Flooring in front of rear roll up door is damaged C� o Recommended Action: Replace damaged flooring with comparable replacement flooring tiles. Receiving/Storage #111 A This room appears to be used for the storage of minor materials. The flooring in this room is in Poor condition and will need to be replaced. The below items were found to need attention; o repair: • Rear exit door bottom threshold has been removed. o Recommended Action: Replace/reinstall bottom threshold as originally designed. Vin-0 flooring is chipped up and scratched due to items being dragged over flooring and due to the removal of the bottom threshold of the east exterior door. o Recommended Action: Replace damaged flooring with comparable replacement flooring tiles as needed to make a uniform floor for both aesthetics and safety. • Door edge located on door going into the Calibration Lab has a bent edge. o Recommended Action: Repair bent door edge to original condition. Calibration Lab 4111 This room is overall in good condition with light wear. There is light storage of items and boxes in this room to include Christmas decorations, a weights, and various file cabinets. The below items were found to need attention repair: 0 4 fluorescent lighting fixtures inoperative. o Recommended Action: Repair inoperative fixtures to operate as originally installed and designed. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.695.2778 239.6415427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -144- 5/14/2013 10. E. inspection Report: KPK Management Inc. Page 5 Unit A and B (92 & #3) — Global Manufacturing This bay- has numerous large machines operating within. The overall condition of this unit was in fair condition. The bay is a combination of 2 bays to form one 2.000 S.F. working space. This space has 2 small offices located near the front entrance of the space. The below items were found to need attention. repair: • Penetrations/holes in fireismoke barrier. o Recommended Action: Repair damage to fire wall in accordance with NFPA 101. * Wall box blank cover missing in front off-ice o Recommended Action: Install blank cover over opening. • Walls in both offices are dirty, scratched, and in need of repair and painting. Northern office has holes in wall and need to be patched. o Recommended Action: Repair ckralls and repaint as needed in accordance with NFPA 101. * Electrical panel circuit schedule is not accurate. o Recommended Action: Reprint and replace current panel circuit schedule with an updated schedule in accordance with NFPA 70. 0 Fire strobeliorn is broke o Recommended Action: Replace broken strobe horn in accordance with NFPA 72. • Wires coming out of electrical panel in Unit B not properly hung or protected. o Recommended Action: Protect and rerun wiring in accordance with NFPA 70. • Some overhead florescent fixtures inoperative. o Recommended Action: Repair inoperative fixtures to operate as originally installed and designed. Unit C (Bay #4) — Gulf Connectors This ba% hassioraLe of various items and overall in good.. working condition. The belo,%v Items Were found to need attention,, I repair: • Ceiling, insulation is torn, and falling down from ceiling (identified on previous imspection report fro in 3 )/1 !1) 0 1 2). o Recommended Action: Repair insulation back to original position and installation, If required, replace insulation. Marco island Executive Airport immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 immokaiee, FL 34142 Everglades City, FL 34139 239,394,3355 239.657.9003 239-695.2779 239.642,5427 Fax 239.657,9191 Fax 239.695.3558 Fax Packet Page -145- 5/14/2013 10. E. inspection Report: KPK Management Inc. Page 6 • Insulation missing on wall to the right of the rear overhead door and holes in metal paneling a Recommended Action: Replace missing insulation with comparable replacement and seal all openings in metal paneling. • 2 fluorescent lighting fixtures inoperative. r, Recommended Action: Repair inoperative fixtures to operate as originally installed and designed. • Thermostat for air conditioning is broken. c Recommended Action: Replace thermostat. • utility sink is missing faucet and the wall is damaged directly behind sink. o Recommended Action: Replace missing faucet on utility sink and repair firetsmoke barrier behind utility sink in accordance with NFPA 101. Emit 11 (Ray #5) — Gulf Connectors The below items were found to need attention /repair: • Ceiling insulation is torn and falling down from ceiling, (ldentifiecf on previous inspection report from 31 /2012). o Recommended Action: Repair insulation back to original position and installation. If required. replace insulation. • Thennostat for air conditioning is broken. o Recommended Action: Replace thermostat. • Penetrations/holes in north and south fire /smoke barriers. o Recommended Action: Repair damaged sections of the fire w=alls in accordance with NFPA 101. • llev<ated disconnect located near center of space is missing cover (Identified on previous inspection report from 3/1,'2012). o Recommended Action: Install a suitable cover over disconnect per NFPA 70. .1 -Box with fire alarm duct detector Wiring, is missing a cover and wires are hanging out o Recommended Action: Fire Alarm wiring needs to be properly secured N-, thin the j- box by an approved fire alarm contractor and a blank cover needs to be installed in :accordance ,vith NFPA 72. • Insulation missing* on both sides of the rear overhead door. o Recommended Action: Replace missing insulation with comparable replacement. Marco island Executive Airport Immokaiee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114 -8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394.3355 239.657.9003 239.69S.2778 239:642.5427 Fax 239.657.9191 Fax 239.695_3558 Fax Packet Page -146- 5/14/2013 10.E. Inspection Report: KPK Management Inc. Page 7 L,� nit rear exit door has unapproved sliding pin hardware installed that prevents the proper operation of the door. c Recommended Action: Remove unapproved exit hardware and maintain exit door in accordance \kith NFPA 101. There is an accumulation of metal shavings from metal working machines. o Recommended Action: Maintain a clean and safe work-place and properly dispose of metal shavings in accordance with FFPC. Unit E (Bay #6) - Storage This bav was in good condition overall with minimal issues. The lessee's representative stated that I repair, the space is ccurrently heing used for storage. The below items were found to n eed attentiory Exit sign over rear exit door is missing/not installed, -- Recommended Action: Install an approved exit sign in accordance with NFIIA 101. Electrical panel circuit schedule is not accurate. o Recommended Action: Reprint and replace current panel circuit schedule with an updated schedule in accordance with NFPA 70. 11 Drvxvall around front entrance door is damage and there is a large hole located near the floor that appears to be made by a small animal or rodent. o Recommended Action: Repair all penetrations in the smoke/fire barrier per NFPA 101, and ensure that there are no nuisance animals living in building. Unit F and G (Bay #7 & #8) — Green Secure The Airport Management does not have record of approving this company's sublease as required in the approved and signed lease between the building lessee and the Authority. Lighting fixtures looked to be in good repair and condition. There is minor damage to the fire wall that needs to be addressed. The F elow items were found to need attention/repair: Emergency light located on South wall does not illuminate on battery power when manually tested ( Identified on previous inspection report from 3!1/2012). o Recommended Action: Repair/replace emergency light in accordance with NFPA I W. 0 Thermostat for air conditioning broken, c) Recommended Action: Replace thermostat. • Rollup door cover missing (Identified on previous inspection report from3!1 '20121. o Recommended Action: Reinstall rollup door cover to operate as designed. Marco Island Executive Airport immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 Immokalee, FL 34142 Everglades City, FL 34139 239.394,3355 239.657.900 239,695.2779 239.642.5427 Fax 239.657,9191 Fax 239.6953558 Fax Packet Page -147- 5/14/2013 10. E. inspection Report: KPK Management Inc. Page 8 Insulation missing on both sides of the rear overhead door. o Recommended Action: Replace missing insulation with comparable replacement. a Electrical panel circuit schedule is not accurate. o Recommended Action: Reprint and replace current panel circuit schedule with an updated schedule in accordance with NFPA 70. Penetrations./holes in south firefsmoke barriers. o Recommended Action: Repair damaged sections of the fire wall in accordance with. NFPA 101. Fire alarm pull station is missing "local monitored placard." o Recommended Action: Contact fire alarm contractor and secure the proper placard to area above fire alarm pull station in accordance writh INHA 72. « Fire/smoke barrier missing required '-fire wall" placards o Recommended Action: Install approved fire wall placards on all affected walls in accordance with NFPA 101. E- mergency light is missing in Bay #S c Recommended Action: Install and maintain emergency light in accordance with NFPA 101 (Identified on previous inspection report from 1/l/2012). t Receptacle cover missing from receptacle under electrical panel o Recommended Action: Install an approved receptacle cover in accordance with NFPA 70. Unit H & I (Bay #9 & #10) - Salazar Machine and Steel This bav is subleased to Salazar Machine and Steel. It is a combined bay with 2000 S.F. of continuous space. There is an accumulation of cobwebs in the ceiling but the overhead lighting was in good repair and all worked. At the time of the inspection, the sub - tenant was in the prowess of vacating the units. The below items were found to need anention/repair: & Penetrationslholes in Fire /Smoke Barrier. o Recommended Action: Repair damaged sections of the fire %walls in accordance with NFPA 101. « l "lectrical Panel is missing: screws (Identified on previous inspection report from 3/1/2012). o Recommended Action: Install screws to hold panel cover flush with wall. Marco Island Executive Airport immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Atrpark Road Naples. FL 34114 -8955 Immokalee, FL 34142 Everglades City, F! 34139 239.394.3355 239.657.9003 239.695.2778 239.6425427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -148- 5/14/2013 10. E. Inspection Report: KPK Management Inc. Page 9 0 Ceilino r, insulation is torn and falling down from ceiling (Identified on previous inspection report from 3/l/201-1). o Recommended Action: Repair insulation back to original position. If required. replace insulation. • Electrical panel circuit schedule is not accurate. o Recommended Action: Reprint and replace current panel circuit schedule with an updated schedule in accordance with NFPA 70. 0 Exterior of bay door opening has sheet metal damage from collision with an object or vehicle (Identified on previous inspection report from 3 3/1,12012). o Recommended Action: Repair or replace the metal as required. • Insulation missing on both sides of the rear man and overhead door. o Recommended Action: Replace missing insulation with a comparable replacement. • Insulation failing down around roof vent c Recommended Action: Reattach insulation around roof vend with proper tape and hardware to prevent future failure. Unit J (Bay #11) This bav is also subleased to Salazar Machine and Steel and is showing signs of overuse. There is wall damage to the western wall of the building that has been left unrepaired. The tenant has installed a Shed within the premises that the Fire Marshal wrote up as "work done without a permit." The unit's overhead lighting was in working order with some bulbs and fixtures not workine as designed. The below items were found to need attention,/repair: • Ceiling insulation is torn and falling down from ceiling (Identified on previous inspection report from 3/112012). o Recommended Action: Repair insulation back to original position. if required. replace insulation. * Electrical panel circuit schedule is not accurate. o Recommended Action: Reprint and replace current panel circuit schedule with an updated schedule in accordance with NFPA 70. • Thermostat for air conditioning system is broken (Identified on previous inspection report fro n 1 ,11.'20112 ). o Recommended Action: Replace thermostat. Marco island Executive Airport immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevaro 650 E.C. Airpark Road Naples, FL 34114-8955 Immokalee, FL 34142 Everglades City, FL 34139 239-394.3355 239.657.9003 239.69S.2778 239.642.5427 Fax 239.6573191 Fax 239.695.3558 Fax Packet Page -149- 5/14/2013 10.E. inspection Report: KPK Management Inc. Page 10 b 2 fluorescent lighting fixtures inoperative and missing bulb guards- o Recommended Action: Repair inoperative fixtures and add guards to Operate as originally installed and designed. 9 Penetrations/holes in Fire/Smoke Barrier. o Recommended Action: Repair damaged sections Of the fire walls in accordance with NFPA 101. Exterior of Building In accordance with the signed and approved lease, the exterior area of the building to include the lighting. building. and pavement is the sole responsibility of the lessee. The general condition of the rear of the building is littered with trash, debris, metal. wood. vegetation. and equipment scattered around. While the tenant has cleaned up some portion-, of the building*s rear area, this has not been maintained in accordance with the approved lease. The inspection staff conducted a detailed inspection of the exterior of the building and noted the following items: • Pavement markings such as parking spaces. stop bars- and safety lines are faded and /car missing as shown on building plans (Identified on previous inspection report from 31 /2012). o Recommended Action: schedule parking area to be restriped Pavement is in need of seal coat to preserve integfitNY pavement. o Recommended Action: Schedule pavement to be resealed and restriped to preserve pavement and extend useful life. At the rear of the building, trash and debris have been allowed to accumulate in the paved common area. There are weeds and vegetation growing inside the dumpster enclosure and inside stacked pallets near the enclosure (Identified on previous inspection report from 3/1/2'01'_'). o Recommended Action: Remove debris from rear of building in accordance With lease to allow landscaping contractor to safely service the property on a weekly basis. Metal racks and supplies blocking truck pallet lift (Identified on previous inspection report from 3/1:'2012). o Recommended Action- Remove and relocate items to not impact the truck lift. Lift is a common use item that must remain clear and usable from both directions. 0 Rear fire/vehicle lane is being blocked by steel barricades during night and misc. supplies and items are being, stored within the 2-way lane (Identified on previous inspection report from 3/12012). Marco Island Executive Airport immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 Immokalee, FL 34142 Everglades City, FL 34139 239.3943355 239.657.9003 239.6951779 239.642.5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -150- 5/14/2013 10. E. inspection Report: KPK Management Inc, Page 11 o Recommended Action: Remove items from within 2-way fire lane and cease the usaue of the steel barricades at night. In accordance with approved lease. items should not be allowed to accumulate outside the building. rs ra r • Condenser unit enclosures are bent: wiring damaged. 'ed. and has paint ove p y on enclosures (Identified on previous inspection report from 31'1/2012).. o Recommended Action: Do not allow tenants to use condenser units as work, benches and need to have system serviced. Repair the broken electrical fixtures and conduits to meet electrical safety codes. • Front and rear bay doors paint is faded. (Identified on previous inspection report from 3!11'2012). Lessee has painted the exterior of some of the rear doors but has not finished painting the inside of rear doors and the door frames. o Recommended Action: Repaint front doors. re-number, and finish painting rear doors and frames. • Areas of metal panels outside of bay doors in rear are discolored (identified on previous inspection report from 1/1 /2012), o Recommended Degreas Action: g seiclean metal panels • Traffic signs are faded. missing. and need to be replaced (discussed with lessee last year during follow up inspection). o Recommended Action: Replace all faded or missing traffic signs in accordance with approved plans for building. • Oil/Water Separator needs servicing and cleanout records retained for future inspections. Lessee*s representative is not aware of system ever being serviced. o Recommended Action: Have building oil./water separator serviced. • Improper storage of oil in open -5- gallon pails and unmarked containers. o Recommended Action: All oil needs to he stored in accordance with MET requirements including storage in. Lessee needs to maintain records of proper disposal of oil and hazardous liquids. • Exposed building .virinp located at the rear of the building between Units #3 &,414. at A!C units between Units 47 and 98. and at A/C Pad between Ujnits Or9 & #10. n Recommended Action: Repair all damaged electrical conduit and remove exposed wiring that is no longer in use. 0 Directional slanage such as building name and delivery directional sionage has mildew t!rowim, on surfaces. o Recommended Action; Clean all affected signage. Marco Island Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive, Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 Immokalee, FL 34142 Everglades CO, FL 34139 2393943355 239,657.9003 239.695.2778 239,642,5427 Fax 239.657.9191 Fax 239.695.3558 Fax Packet Page -151- 5/14/2013 10. E. Inspection Report: KPK Management Inc. Page 12 All bav floor drains need debris cleaned out of drainage surfaces o r Recommended Action: Clean out floor drains and flush regularly as part of normal building maintenance. Common Use Equipment and Furniture An inspection was conducted on the common use equipment that belongs to the Authority that is positioned over at this , particular building, All the office furniture was rated to be in good condition to its time in service. The forklift is Showing and seemed to be wearing appropriately according signs of wear and needs to be continually maintained as part of this agreement. The seat of the forklift is damaged beyond repair and needs to be replaced. The body of the forklift has severe rust Y issues and needs to be prepped and repainted. In keeping you with the requirements ol'your lease. will need to repair the forklift and maintain it in an operational status. It is a common use item that is required to be maintained and repaired in a timely manner. Sub-Leasing Bays During the inspection of your facility, it was noted that there were tenants moved in and conducting business inside Your facility without having an sub-lease reviewed by the Authority. In accordance with Article IX Assignment and Subletting. sublease ag reements should he approved by the Authority prior to businesses taking occupancy of a facility within the leased building. T Follow I.Jp Inspection A follow-up inspection of your leased building is scheduled for Wednesday. February 27. 2013 y be conducted to verify between the hours of 9:00am and 4:00pm, This follow-up inspection will I that the above non-compliance issues have been resolved and that a maintenance plan has been implemented for any unfinished items. You are requested to be in attendance at this follow-up inspection. Airport 1anagement has coordinated with the Immokalee Fire District Fire Marshal. 1,,eo Rodgers to conduct both follow-up inspections at the same time for your convenience. L_ The goal ofthe Airport Management and Staff is to run a sale. efficient, and friendly Airport for all of our customers. If you have any questions or concerns about your inspection results or any other items in the now or in the future, please feel free to contact the Airport at 2319-657-9003, Sincer-h- A Thomas 'ergo Airport Manager Immok-alee Regional Airport ('c: Chris Curry. CCAA Executive Director Marro Wand Executive Airport Immokalee Regional Airport Everglades Park 2005 Mainsail Drive. Suite 1 165 Airpark Boulevard 650 E.C. Airpark Road Naples, FL 34114-8955 immokalee, FL 34142 Everglades City, FL 3 »139 239.394.3355 239.657.9003 239.695.2778 739.642.5427 Fax 239.657.9191 Fax 239.6953558 Fax Packet Page -152- --'--'- 5/14/2013 10.E. Ceiling Tile Damaged At A/C Vent Location: Men's Bathroom In Office Stained Ceiling Tile Location: Women's Bathroom In Office Packet Page -153- 5/14/2013 10. E. Metal Shavings On Office Carpet Location: Main Office Insulation Failing Dow Location: Tool Room i Roof Insulation Overhead Door Insulation 2 Packet Page -154- 5/14/2013 10. E. J Packet Page -155- 5/14/2013 10. E. Panel Listing Faded /Not Accurate Location(s): Throughout Building Packet Page -156- .4 r �N �91Y 4 l Packet Page -156- 5/14/2013 10. E. Packet Page -157- 5/14/2013 10. E. Packet Page -158- x k , Packet Page -158- -'-'--'- 5/14/2013 1O.E. 'Fire Alarm Horn/Strobe Brok 7 Packet Page -159- 5/14/2013 10. E. Unsealed Pipe and Missing Insulation Location: Unit 4 Packet Page -160- 5/14/2013 10. E. Sink Missing Faucet and Wall Cracked -agempm 1 'w Lew 9 Packet Page -161- 5/14/2013 10. E. 10 Packet Page -162- 5/14/2013 10. E. 11 Packet Page -163- i 5/14/2013 10. E. Packet Page -164- • 12 W-j 5/14/2013 10. E. EE-mergency Light Missing Location: Unit 8 Packet Page -165- 5/14/2013 10.E. Insulation Failing Off Around Vent Location: Unit 9 & 10 14 Packet Page -166- K01 5/14/2013 10. E. Insulation Falling Dow 4 Location: Unit 9 & 10i KOK Packet Page -167- 5/14/2013 10.E. Oils and Liquids Improperly Stored Location: Rear of Building (Inside Shed) OIL ISSUE RESOLVED according to Authority email 5/3/13 to Commissioner Henning (see email next page) 16 Packet Page -168- 5/14/2013 10.E. E1MIL SUPPORT OE 3NSPECIATION PAGE "15 - OILS AND LIQUIDS ISSUE ":RESOLVED From: CurryChris Sent: Friday, May 03, 2013 9:52 AM To: SmithCamden Cc: VergoThomas Subject: RE: 2013 KPK Lease Inspection Photos - Immokalee Airport - Email #1 Camden, The oil storage issue has been resolved based on the post inspection letter from Thomas Vergo dated March 11, 2013 Chris Curry, C.M. Executive Director Collier County Airport Authority (W)239- 642 -7878 x35 (C) 239 - 269 -3353 - - - -- Original Message---- - From: SmithCamden Sent: Friday, May 03, 2013 9:05 AM To: VergoThomas Cc: CurryChris Subject: RE: 2013 KPK Lease Inspection Photos - Immokalee Airport - Email #1 Do the oil storage issue still exist? Respectfully, Camden Smith, MPA Executive Coordinator to Commissioner Henning Board of County Commissioners Ph: (239) 252 -8605 Email: CamdenSmith @colliergov.net Notice to recipients: All emails and attachments received or sent regarding county business and /or BCC agenda items are public record in compliance with the State of Florida's Sunshine Law. - - - -- Original Message---- - From: VergoThomas Sent: Thursday, May 02, 2013 9:33 PM To: SmithCamden Cc: CurryChris Packet Page -169- 5/14/2013 10.E. Subject: 2013 KPK Lease Inspection Photos - Immokalee Airport - Email #1 Attached are photos from the inspection of 2013 lease compliance inspection of KPK (Larry Fox). Thomas Vergo, C.M. Airport Manager Immokalee Regional Airport Collier County Airport Authority 239 - 657 -9003 Office 239 - 465 -9983 Cell 239 - 657 -9191 Fax Under Florida Law, e -mail addresses are public records. If you do not want your e -mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Under Florida Law, e -mail addresses are public records. If you do not want your e -mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Under Florida Law, e -mail addresses are public records. If you do not want your e -mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Packet Page -170- 5/14/2013 10. E. EMST-41WISIS KGr Aaiag7r w in k.e.ase 17 Packet Page -171- 5/14/2013 10. E. Parking Let Lines Faded and Asphalt In Need of Seal Coat • m Packet Page -172- 5/14/2013 10. E. Unapproved Light Location: Flag Pole ,g Packet Page -173- 5/14/2013 10. E. OF'SUB- LEASES AS REQUIRED BY.LEASE A( From: CurryChris Sent: Thursday, May 02, 2013 2:06 PM To: SmithCamden Subject: FW: Subleases with Tenants FYI Chris Curry, C.M. Executive Director Collier County Airport Authority (W)239- 642 -7878 x35 (C) 239 - 269 -3353 From: CurryChris Sent: Tuesday, April 16, 2013 10:04 AM To: 'globalmfg3 @aol.com' Cc: VergoThomas; Klatzkow3eff Subject: Subleases with Tenants Mr. Fox, I would like to request copies of all the leases that you have with tenants that reside in your facility at the Immokalee Regional Airport. Please let me know when they will be available to pickup or copy. Thanks Chris Curry, C.M. Executive Director Collier County Airport Authority (W)239- 642 -7878 x35 (C) 239 - 269 -3353 Finder Florida Law, e -mail addresses are public records. If you do not want your e -mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by telephone or in writing. Packet Page -174-