Agenda 02/26/2013 Item #16A10 Proposed Agenda Changes
Board of County Commissioners Meeting
February 26,2013
Withdraw Item 6A: Public petition request from Richard Van Deelen requesting that the Board give
direction for an analysis of a Municipal Services Benefit Unit(MSBU) for the La Peninsula Condominium
residents to replace the Sea Wall. (Petitioner's request)
Continue Item 6B to the March 12,2013 BCC Meeting: Public Petition request from Randall J.Cohen
regarding practices and procedures. (Petitioner's request)
Withdraw Item 10A: Appointment of member to the Collier County Planning Commission.
(Commissioner Hiller's request)
Continue Item 16A10 to the March 12, 2013 BCC
Meeting: Recommendation to approve Change
Order No. 5 to Contract # 09-5278 in the amount of
$350,000 and for an additional 413 days (Phase I) with
Stanley Consultants, Inc., for Design & Related
Services for the Intersection Capacity Improvements
to the US 41 and SR/CR 951 Intersection and
Resurfacing, Restoration and Rehabilitation (3R)
roadway improvements to SR 951; project # 60116.
(Staff's request)
Continue Item 16F1 to the March 12,2013 BCC Meeting: Recommendation to authorize amendment#2 for
contract 09-5174 Management of Pelican Bay Services to Dorrill Management Group to increase the number
of hours per month,fees and the contract period to Dorrill Management Group and extend the term for
additional two(2)year term; and authorize the Chairwoman to approve the amendment. (Staff's request)
Move Item 16G2 to Item 14A1: Recommendation to direct the Airport Director to bring back in March a
plan to reduce or eliminate the Annual Fund transfer and to pay back the County loan. (Commissioner
Coyle's request)
Add On Item 16J4: To obtain Board approval for disbursements for the period of February 14,2013
through February 20,2013 and for submission into the official records of the Board. (Clerk of Courts
Finance Department)
2/26/2013 16.A.10.
EXECUTIVE SUMMARY
Recommendation to approve Change Order No. 5 to Contract # 09 -5278 in the amount of
$350,000 and for an additional 413 days (Phase I) with Stanley Consultants, Inc., for
Design & Related Services for the Intersection Capacity Improvements to the US41 and
SR/CR951 Intersection and Resurfacing, Restoration and Rehabilitation (3R) roadway
improvements to SR951; Project # 60116.
OBJECTIVE: This change order is as a result of scope enhancements that could not have been
foreseen during the original scope development and to add funding for post design services.
CONSIDERATIONS: On January 26, 2010, the BCC approved Professional Services
Agreement Contract # 09 -5278 with Stanley Consultants Inc., for design improvements to the
US41 & SR/CR951 intersection and Resurfacing, Restoration and Rehabilitation (3R) of SR951
(Fiddlers Creek Parkway to Tower Road) under project # 60116. The scope changes resulting in
this Change Order No. 5 are as follows:
Modifications to Design Scope of Services for Capacity Improvements to US41 and SR/CR951
Intersection - (Impact Fees Funded)
Affected Scope Tasks: 4.4A, 4.5A, 4.10A, 4.11A, 4.14A, 4.15A, 4.17A, 4.18A, 5.2A,
5.3A, 5.6A, 5.7A, 5.10A, 5.14, 5.15A, 5.22A, 5.23A, 5.26, 6.9A, 6.13A, 6.15A, 6.19A,
6.21A, 6.22A, 20.1A, 20.3A, 20.6A, 20.14A, 20.15A — Roadway Analysis & Plans,
Drainage & Signing and Marking (Bus stop enhancements) - $53,018.00 (Lump Sum).
During the 60% and 90% design review phases the Alternative Transportation Mode
(ATM) Department determined that additional bus stop locations and enhancements were
needed along certain routes. These enhancements included new bus stops concrete pads,
closed shelters and bus pull outs on CR 951 northbound and southbound in the area of
Triangle Boulevard and CR951. These requests were in response to the community's
needs that were identified in ATM's long range transportation plan study and were
anticipated in the original scope of services; but were not able to be quantified until later
in the design.
2. Affected Scope Tasks: 4.4B, 4.5B, 4.1OB, 4.11B, 4. 13, 4.14B, 4.15B, 4.17B, 4.18B, 5.213,
5.313, 5.4, 5.6B, 5.7B, 5.1OB, 5.1513, 5.21, 5.22B, 5.23B, 5.26, 6.7, 6.9B, 6.13B, 6.15B,
6.17, 6.18, 6.19B, 6.21B, 6.22B, 10.5B, 10.7C, 10.8C, 10.10, 10.11C, 10.12C, 10.14C,
10.15C, 18.12 - 18.18,27, 30B, 32.5 — Roadway Analysis, Plans, Drainage, Structures,
Geotechnical, Survey & Noise Study Report (update) — Eagle Creek Noise Wall -
$59,620.00 (Lump Sum). The Eagle Creek Community qualified for a 21 -ft sound barrier
to the north and south of their entrance on SR951. Through various public meetings,
community meetings and surveys, the Eagle Creek Community expressed their
dissatisfaction with a 21 -ft high wall. The Noise Study was reevaluated and the results
revealed that a shorter noise wall (16.8 ft) meeting FHWA criteria could be constructed to
mitigate noise but only for those residents living on the south side of their main entrance.
The community has agreed to a shorter wall to the south of their entrance provided that
the aesthetics met the community's desires. These aesthetic enhancements will require the
Packet Page -1158-
2/26/2013 16.A.10.
design and construction of a gravity wall and earth embankment in front of the noise wall
to give the appearance of being 12 -ft high on the front side (roadway). Since noise
mitigation could not be achieved with a shorter wall for the residents to the north of their
entrance, Eagle Creek has asked the County to design and construct a shorter wall on
their property to provide the same aesthetic continuity to the north of their entrance.
These changes while not specifically identified under the Noise Study section of the
original scope of services are necessary to mitigate the impacts to the community's
quality of life that will be disrupted by the project if not implemented.
3. Affected Scope Tasks: 10.1, 10.3, 10.4, 10.7A, 10.8A, 10.11A, 10.12A, 10.14A, 10.15A
— Structures (Light Pole Foundations) - $15,320.00 (Lump Sum) The FDOT issued a new
design memorandum for light pole foundations that will require the redesign of the entire
lighting system for the project. The FDOT District One who has final design oversight for
this project made the request after the 90% design phase. Light pole foundation design
was part of the original scope of services; however, it was not anticipated that the FDOT
design criteria would change at the 90% phase of the project necessitating this need for 8
additional detail sheets to be added to the construction plans.
4. Affected Scope Tasks: 10.8B, 10.11B, 10.12B, 10. 1413, 10.15B, 18.6, 19.5- 19.10, 19.12,
19.13, 19.14, 19.16, 19.17, 20.1B, 20.313, 20.4, 20.6B, 20.7, 20.8, 20.12, 20.13, 20.1413,
20.15B, 30A — Structures (Cantilever Sign Structures) - $50,994.00 (Lump Sum) At the
90% design review phase the FDOT requested that five (5) new cantilever signs
structures be included in the project. Signage design was part of the original scope of
services; however, it was not anticipated that the FDOT design criteria would change at
the 90% phase of the project necessitating this change to the construction documents.
5. Affected Scope Task: 22.6 - Signalization Analysis and Plans (Interconnection Plans) -
$13,196.00 (Lump Sum) New Collier County ITS CCTV cameras are needed on the
northwest and southwest steel strain poles within in the US41 & SR/CR 951 intersection.
As a result additional conduits and fiber are to be installed. Signalization was included in
the original scope of services; however, these changes became necessary to meet the
current County signalization specifications and criteria.
6. Affected Scope Tasks: 29.2, 29.3, 29.4, 29.5 & 7.7 - Mapping (Right of Way) -
$47,247.00 (Lump Sum) The County has hired outside Counsel to assist with evaluating
the right -of -way needs for the project and cost reduction. As a result, various right of way
documents need revision and new ones are needed due to some of the parcels being split
into separate parcels. The original scope of services included Right of Way mapping;
however, the number of revisions needed exceed the estimated project scope
requirements.
7. Post Design Services - $100,000.00 (Time and material not to Exceed) At the time the
design contract was negotiated the services for post design were added to the scope.
These tasks included Bidding services, Shop Drawings Reviews, Responses to RFIs and
SFWMD Project Certification. The fee for these tasks were not negotiated as part of the
final design fees due to the fact that this project was being done as a Joint Participation
Agreement with the FDOT and the level of effort required to execute this task could not
be properly quantified at that time. Now that the project has reached a more substantial
level of design, the effort for this task can be properly estimated.
Packet Page -1159-
2/26/2013 16.A.10.
Modifications to Design Scope of Services for Resurfacing, Restoration and Rehabilitation (3R)
Improvements to SR951 Intersection (Gas Taxes Funded)
Affected Scope Tasks: 18.5, 21.5, 21.8, 21.10, 21.11, 21.15, 21.16, 21.18, 21.19, 22.3,
22.4, 22.5, 22.11, 22.17, 22.18 – Structures Miscellaneous (Lighting on Signal Mast
Arms) – $10,605.00 (Lump Sum) At the 30% design phase, a Lighting Justification Study
was completed for this segment of CR 951 and concluded that there was no need for
roadway lighting within the 3R project limits. At the 90% design review phase, the
County's Traffic Operations Department requested that spot lighting be included in the
design at the intersection of Manatee Road and Collier Boulevard to enhance the safety of
the intersection. Lighting design was included in the original scope of services; however,
these enhancements are necessary for public health and safety.
The original professional service agreement negotiated was $13M and the current amount under
contract is $1.978M. This change order represents 17.69% of the current amount.
FISCAL IMPACT: Funds in the amount of $339,395.00 are available within Impact Fees for
the intersection capacity improvements. For the 3R improvements, funds in the amount of
$10,605.00 are available in Gas Taxes.
LEGAL CONSIDERATIONS: This item has been reviewed and approved by the County
Attorney's Office, is legally sufficient for Board action and only requires a majority vote for
approval —SRT.
GROWTH MANAGEMENT IMPACT: The project has been adopted in the CIE and is
consistent with the Long Range Transportation Plan.
RECOMMENDATION: That the Board of County Commissioners approves the Change
Order No. 5 to contract 09 -5278 to Stanley Consultants, Inc. and authorize the necessary budget
amendment.
PREPARED BY: Marlene Messam, P.E., Sr. Project Manager, Transportation Engineering &
Construction Management Department.
Attachments: 1) Change Order#5; 2) Change Order Modification #5; 3) Exhibit A SA #5 Scope of
Services and Fee Proposal
Packet Page -1160-
2/26/2013 16.A.10.
COLLIER COUNTY
Board of County Commissioners
Item Number: 16.16.A.16.A.10.
Item Summary: Recommendation to approve Change Order No. 5 to Contract # 09 -5278
in the amount of $350,000 and for an additional 413 days (Phase 1) with Stanley Consultants,
Inc., for Design & Related Services for the Intersection Capacity Improvements to the US 41 and
SR /CR 951 Intersection and Resurfacing, Restoration and Rehabilitation (3R) roadway
improvements to SR 951; project # 60116.
Meeting Date: 2/26/2013
Prepared By
Name: MessamMarlene
Title: Project Manager, Senior,Transportation Engineering
1/29/2013 5:29:30 PM
Submitted by
Title: Project Manager, Senior,Transportation Engineering
Name: MessamMarlene
1/29/2013 5:29:31 PM
Approved By
Name: KearnsAllison
Date: 2/6/2013 2:33:57 PM
Name: LynchDiane
Title: Administrative Assistant
Date: 2/6/2013 5:23:24 PM
Name: ShueGene
Date: 2/6/2013 6:10:19 PM
Name: AhmadJay
Title: Director - Transportation Engineering,Transportation Engineering & Construction Management
Date: 2/7/2013 7:20:39 AM
Packet Page -1161-
2/26/2013 16.A.10.
Name: TaylorLisa
Title: Management/Budget Analyst,Transportation Administr
Date: 2/7/2013 3:00:35 PM
Name: PutaansuuGary
Title: Project Manager, Principal,Transportation Engineer
Date: 2/8/2013 9:25:23 AM
Name: MarkiewiczJoanne
Title: Manager - Purchasing Acquisition,Purchasing & Gene
Date: 2/9/2013 4:17:09 PM
Name: CummingsRhonda
Title: Contracts Specialist,Purchasing & General Services
Date: 2/12/2013 1:23:09 PM
Name: LynchDiane
Title: Administrative Assistant
Date: 2/13/2013 9:37:15 AM
Name: PuigJudy
Title: Operations Analyst, GMD P &R
Date: 2/13/2013 4:22:16 PM
Name: Jecika Cook
Title: Operations Coordinator,Transportation Engineering
Date: 2/13/2013 4:30:23 PM
Name: PuigJudy
Title: Operations Analyst, GMD P &R
Date: 2/ 14/2013 88:57.22 )VA
Name: CummingsRhonda
Title: Contracts Specialist,Purchasing & General Services
Date: 2/14/2013 11:12:14 AM
Name: CummingsRhonda
Title: Contracts Specialist,Purchasing & General Services
Date: 2/14/2013 11:13:19 AM
Name: MarcellaJeanne
Title: Executive Secretary,Transportation Planning
Date: 2/14/2013 12:57:00 PM
Packet Page -1162-
Name: Joshua Thomas
Title: Grants Support Specialist,
Date: 2/15/2013 11:10:51 AM
Name: TeachScott
Title: Deputy County Attorney,County Attorney
Date: 2/19/2013 4:57:34 PM
Name: KlatzkowJeff
Title: County Attorney
Date: 2/20/2013 8:23:16 AM
Name: UsherSusan
Title: Management/Budget Analyst, Senior,Office of Manage
Date: 2/20/2013 11:39:31 AM
Name: OchsLeo
Title: County Manager
Date: 2/20/2013 1:34:41 PM
Packet Page -1163-
2/26/2013 16.A.10.
2/26/2013 16.A.10.
Supplement #5
Scope Items
02 -05 -2013
US 41 -CR 951 (Phase 1) Supplement (from 60% -100% and Post Design)
SR 951311 (Phase IA) Supplement (Post 90 %)
TASK 4.4A, 4.5A, 4.10A, 4.11A. 4.14A, 4.15A, 4.17A, 4.18A, 5.2A. 53A, 5.6A 5.7A 5.10A 5.14, 5.15A,
5.22A, 5.23A, 5.26, 6.9A, 6.13A, 6.15A, 6.19A, 6.21A, 6.22A, 20.1A 20.3A 20.6A 20.14A 20.15A
BUS STOPS AND PULLOUTS
ORIGINAL SCOPE:
2. PROJECT DESCRIPTION
2.1 Roadway
Plan Type: Plan /Profile
Typical Sections:
Intersection Improvements (Phase 1): Design will be based on the preferred interim at -grade
improvements shown in Appendix B, Conceptual Intersection Improvement Study Report for US 41 and
CR 951, November 2008.
Limits:
Intersection improvements (Phase 1): The project limits are shown in the Interim At -Grade Conceptual
Plan, Appendix B, and Conceptual Intersection Improvement Study Report for US 41 and CR 951,
November 2008; a distance of approximately 1.0 miles.
SR /CR 951 - RRR PROJECT (Phase IA): From Milepost 6.332 to Milepost 9.551— a distance of 3.219 miles.
Design of the RRR project (Phase IA) will be in accordance with the FDOT's PPM, FDOT Design Standard
and the governing Standard Specifications for Road and Bridge Construction. The resurfacing project
shall include conversion of the existing span wire signal system to mast arms at two (2) intersections —at
mile post 8.491 and mile post 8.615.
In addition, striped and signed bike lanes shall be included throughout the project. During the design
phase, all guardrails within the project limits shall be field verified, and the COUNTY shall replace all
guardrails within the project limits deemed necessary by the FDOT. The CONSULTANT shall design any
thrierail connection retrofit at the bridges at Henderson Creek ( #030289 and #030288) as deemed
necessary by the FDOT. Bus stops will be enhanced at Manatee Road (both NB and SB), with bus bays
and waiting pads with shelters. A bus stop at Wal -Mart will be considered an optional service.
4. ROADWAY ANALYSIS
4.4A Horizontal /Vertical Master Design Files
The CONSULTANT shall design the geometrics using the design standards that are most appropriate with
proper consideration given to the design traffic volumes, design speed, capacity and levels of service,
functional classification, adjacent land use, design consistency and driver expectancy, aesthetics,
pedestrian and bicycle concerns, ADA requirements, elder road user policy, access management and
scope of work.
4.5A Cross Section Design Files
The CONSULTANT shall establish and develop cross section design files in accordance with the FDOT
CADD manual.
Packet Page -1164-
2/26/2013 16.A.10.
4.10A Computation Book and Quantities
The CONSULTANT shall prepare the Computation Book per the FDOT Basis of Estimate Manual and pay
item structure, and provide various summaries of quantities sheets. This includes all efforts required to
develop the Computation Book and the supporting documentation, including estimated construction
days when required.
4.11A Cost Estimate
The CONSULTANT shall prepare the Engineer's Estimate of Probable Cost and provide at each submittal
phase. The Engineer's Estimate of Probable Cost shall be adjusted at each submittal to be maintained
until final submittal.
4.14A Technical Meetings
Includes; meetings with the COUNTY or other Agency staff, between disciplines and CONSULTANTS, such
as access management meetings, pavement design meetings, progress review meetings (phase review),
road safety audit and miscellaneous meetings necessary for all elements of the roadway analysis
identified in this scope of work.
4.15A Quality Assurance /Quality Control
The CONSULTANT shall be responsible for the professional quality, technical accuracy and coordination
of all surveys, designs, drawings, specifications and other services furnished by the CONSULTANT under
this contract
4.17A Supervision
Includes all efforts required to supervise all technical design activities.
4.18A Coordination
Includes: efforts to coordinate all elements of the roadway analysis to produce a final set of
construction documents.
S. ROADWAY PLANS
5.2A Summary of Pay Items Sheets (Including Quantity Input)
53A Drainage Map Sheets (Phase I only)
5.6A Summary of Quantities Sheets
5.7A Summary of Drainage Structures Sheets (Phase I only)
5.10A Plan /Profile Sheets (Phase I only)
5.14 Miscellaneous Detail Sheets
5.15A Drainage Structure Sheets (Phase I only)
5.22A Cross Sections (Phase I only)
5.23A Conceptual Traffic Control Plan Sheets (Phase I only)
5.26 Utility Adjustment Sheets
6. DRAINAGE ANALYSIS
6.9A Design of Storm Drains (Phase I only)
Develop drainage maps; determine runoff, inlet locations, and spread. Calculate hydraulic losses
(friction, utility conflict and, if necessary, minor losses). Determine Design Tailwater and, if necessary,
outlets scour protection.
2
Packet Page -1165-
2/26/2013 16.A.10.
6.13A Drainage Design Documentation Report (Phase I only)
Compile drainage design documentation into report format. Include documentation for all the drainage
design tasks and associated meetings and decisions, except the Pond Siting Analysis Report.
6.15A Cost Estimate
The CONSULTANT shall prepare the Engineer's Estimate of Probable Cost and provide with the each
submittal phase. The Engineer's Estimate of Probable Cost shall be adjusted at each submittal to be
maintained until final submittal.
6.19A Quality Assurance /Quality Control
The CONSULTANT shall be responsible for the professional quality, technical accuracy and coordination
of all surveys, designs, drawings, specifications and other services furnished by the CONSULTANT under
this contract.
6.21A Supervision
Includes all efforts required to supervise all technical design activities.
6.22A Coordination
Includes efforts to coordinate all elements of the drainage analysis of the project to produce a final set
of construction documents.
20. SIGNING AND PAVEMENT MARKING PLANS
The CONSULTANT shall prepare a set of Signing and Pavement Marking Plans in accordance with the
Plans Preparation Manual that includes the following.
20.1A Key Sheet
203A Tabulation of Quantities
20.6A Plan Sheets
20.14A Quality Assurance /Quality Control
20.15A Supervision
OUT OF SCOPE REQUEST:
The scope did not include and we did not anticipate providing (1) enhanced bus stop & pull out for the
US41 -CR951 Intersection along the CR951 north leg and providing (1) pull out for the US41 -CR951
Intersection along the CR951 south leg.
Per Marlene Messam' s 2 -1 -2013 email — On CR951 bus pads and pull outs will be constructed on the
northbound (east side) as depicted on the attached that was previously prepared by Stanley. The
exception is that no bus pad is to be included on the southbound (west side) of CR 951 as shown on the
attached. The reason being unavailability of right of way. A pull out will be included for the southbound
(west side) of CR 951.
REQUESTED COMPENSATION: $53,018 (Lump Sum)
3
Packet Page -1166-
2/26/2013 16.A.10.
TASK 10.1 10.3,10.4,10.7A. 10.8A 10.11A, 10.12A. 10.14A, 10.15A
DISTRICT ONE LIGHT POLE POLICY
ORIGINAL SCOPE:
10 STRUCTURES - SUMMARY AND MISCELLANEOUS TASKS AND DRAWINGS
10.1 Index of Drawings
10.3 General Notes and Bid Item Notes
10.4 Incorporate Florida Department of Transportation Standards
103A Computation Book and Quantities
10.8A Cost Estimate
10.11A Technical Meetings
10.12A Quality Assurance /Quality Control
10.14A Supervision
10.15A Coordination
18. STRUCTURES - MISCELLANEOUS
18.19 —18.22
Special Structures (Not applicable for this project)
OUT OF SCOPE REQUEST:
Per FDOT District One Design Practices / Policies Notebook (Updated 2011)
Design Change Memorandum (District One Only) — Foundations for Light Poles
We agreed, as a result of the Production /Operations Workshops, that in District One the foundations for
light poles on urban projects (curb and gutter), would use Spread Footers as the standard foundation
design in lieu of some other type of pre -cast, or cast -in -place foundation.
We also recognized that Spread Footers should be used, when appropriate to avoid conflicts on
suburban projects. The primary reason for the change is to avoid utility conflicts common on these types
of projects.
The scope did not include and we did not anticipate providing spread footer details and notes including
8 special details for the US41 -CR951 Intersection.
REQUESTED COMPENSATION: $15,320 (Lump Sum)
TASK 22.6 INTERCONNECT
ORIGINAL SCOPE:
22. SIGNALIZATION PLANS (Phases I and IA)
22.6 Interconnect Plans (Phase IA only)
OUT OF SCOPE REQUEST:
Item 22.6, the scope did not include and we did not anticipate providing interconnect plans for the
US41 -CR951 Intersection.
4
Packet Page -1167-
2/26/2013 16.A.10.
In addition per Collier County 60% Comments #122 and #123:
Comment #122:
Install ITS CCTV cameras on northwest and southeast steel strain pole according to the Collier County
Technical Special Provisions, dated January, 2012.
Comment #123
The new controller assembly will require an ITS managed field Ethernet switch for communications.
And per Rick Bossert's 11/12/2012 email:
Please Make these Changes to the Documentation on the Plans for Project # 60116:
Replace Pay item 686 -101 (CCTV) with the ITS Pay item 782 -1 -11 (CCTV). There will be two PTZ cameras
at the intersection, and the correct locations are marked on the 90% plans.
Please add the following ITS Pay items to the 90% Plans or these can be considered the notes for the
100% plans.
Add the Following Pay Items:
a. 783 -1 -121 will be 12 strand SM fiber optic cables. ( LF= as the measured distance of splice box to
signal cabinet plus 50 feet slack)
b. 783 -1 -122 will be 48 strand SM fiber optic cables. ( LF= as measured on plan plus Pull Boxes are to
have 100 feet of Slack, and each Splice Box is to have 100 feet of slack on each side of splice creating
200 feet of slack to be placed in splice box.)
c. 783 -2 -31 Fiber Optic Splices (60 x 1 EA) 12 for signal cabinet splicing and 48 for the splice enclosure.
d. 783 -3 -11 Splice Enclosure (1 EA)
e. 783 -3 -14 Buffer Tube Fan out kit (1 EA)
f. 783 -3 -15 Fiber Patch Panel (1 EA)
g. 784 -1 -1 ITS Managed Field Ethernet Switch (1 EA)
Please add a second Fiber Optic Conduit Labeled "CCIT" along Fiber Optic Backbone path as discussed.
(CCIT= Collier County Information Technology Department)
As agreed CCTO will be remain represented as "Interconnect ". (CCTO= Collier County Traffic Operations
Department)
I would like these plans to be updated to reflect our current Traffic Technical Special Provisions as of July
2012 instead of the January 2012: As far as I can see it would not affect any of the signalization designs,
but it would better represent Collier County and FDOT during the installation of the equipment.
o Please put in a General note saying:
All Fiber Optic communication work will conform to Collier County's Signalization Technical
Special Provisions Dated: July, 2012. Contact Randy Ensell or Rick Bossert at the TMC (239 -252-
5000) for specific details and requirements pertaining to the proposed ITS communications
network improvements. These provisions are available for the public at
http://www.colliergov.net/index.aspx?page=2186
REQUESTED COMPENSATION: $13,196 (Lump Sum)
TASK 18.5.21.5, 21.8, 21.10, 21.11, 21.15, 21.16, 21.18.21.19 22 .3, 22 .4, 22 .5, 22 11 22 17 22.18
MANATEE — SR 951 LIGHTING
ORIGINAL SCOPE:
18. STRUCTURES -MISCELLANEOUS
Packet Page -1168-
2/26/2013 16.A.10.
18.5 Mast Arms
The CONSULTANT shall prepare plans for Signalization Mast Arms (s) at the location(s) specified in
Section 2.7
21. SIGNALIZATION ANALYSIS
21.5 Reference and Master Signalization Design File
The CONSULTANT shall prepare the Signalization Design file to include all necessary design elements and
all associated reference files.
For each signal location CONSULTANT shall include Opticom (infrared system) for pre - emption.
21.8 Pole Elevation Analysis
21.10 Quantities
Includes all work required to determine the quantities of each plan sheet.
21.11 Cost Estimate
The CONSULTANT shall prepare the Engineer's Estimate of Probable Cost and provide with first
submittal. The Engineer's Estimate of Probable Cost shall be adjusted at each submittal to be maintained
until final submittal.
21.15B Technical Meetings
Includes meetings with the COUNTY and other Agency staff, between disciplines, and CONSULTANT,
such as progress review meetings (phase review), and miscellaneous meetings necessary for all
elements of the signalization analysis.
21.16 Quality Assurance /Quality Control
The CONSULTANT shall be responsible for the professional quality, technical accuracy and coordination
of all surveys, designs, drawings, specifications and other services furnished by the CONSULTANT under
this contract.
21.18 Supervision
Includes all efforts required to supervise all technical design activities.
21.19 Coordination
Includes all efforts to coordinate with all elements of the signalization analysis of the project to produce
a final set of construction documents.
22. SIGNALIZATION PLANS (Phases I and IA)
22.3
Tabulation of Quantities
22.4
General Notes /Pay Item Notes
22.5
Plan Sheet
22.11
Mast Arm Tabulation Sheet
22.17
Quality Assurance /Quality Control
22.18
Supervision
OUT OF SCOPE REQUEST:
0
Packet Page -1169-
2/26/2013 16.A.10.
Our approved lighting justification report concluded lighting was not necessary for the SR 951 project.
Per Marlene Messam's 11 -19 -2012 email:
Although the lighting justification report done at 30% phase precluded the need for lighting on this
segment of the project; the County would like to have luminaries installed with the three (3) signal mast
arms at the intersection of Manatee Road and Collier Boulevard. Please review the lighting needs with
John Miller in our Traffic Operations Department before finalizing the 100% plans.
The scope did not include and we did not anticipate providing lighting on mast arms at the Manatee /
SR 951 intersection for the SR951 3R project.
REQUESTED COMPENSATION: $10,605 (Lump Sum)
TASK 29.2, 29.3.29.4.29.5 R/W AND LEGALS & SKETCHES
ORIGINAL SCOPE:
29. MAPPING
The CONSULTANT will be responsible for the preparation of right of way maps, maintenance maps,
sketches and legal descriptions as required for this project in accordance with all applicable Manuals,
Procedures, Handbooks, and Florida Statutes. All maps, surveys and legal descriptions will be prepared
under the direction of a Florida Professional Surveyor and Mapper (PSM) to Collier County size and
format requirements utilizing approved software, and will be designed to provide a high degree of
uniformity and maximum readability. The CONSULTANT will submit maps, legal descriptions, quality
assurance check prints, checklists, electronic media files and any other documents as required for this
project to the COUNTY for review at stages of completion as negotiated.
OUT OF SCOPE REQUEST:
29.2 Sketch and Description
Due to changes in the proposed footprint of the new Roadway, the Right of Way needs increased
significantly. The original Fee was based on the estimation of preparing of eight (8) legal descriptions
and sketches per the intersection study. Based on the 1 -28 -2013 meeting with FPL, (2) additional legal
descriptions and sketches are required. The total number of sSketches that are needed totals 57; this
includes revising previously submitted sketches and the creation of new ones.
29.3 Right -of -Way Mapping
The complexity, amount of annotation, increased number of parcels also necessitates major changes
and additional sheets to the Right of Way maps.
29.4 Coordination and 29.5 Plan Revisions
CONSULTANT to respond to questions and comments from the County Right of Way Department. This
also results in modifying the roadway design to aid in right of way mitigation costs at the southwest
quadrant of the intersection adjacent to Walgreens.
We did not anticipate providing additional legals and sketches and the additional efforts required to
complete the Right of Way maps and plans.
7
Packet Page -1170-
2/26/2013 16.A.10.
REQUESTED COMPENSATION: $45,167 (Lump Sum)
TASK 10.86 10.118 10.128 10.146 10.158 18.6,19.5-19.10,19.12,19.13,19.14,19.16,19.17, 20.18
20.36, 20.4.20.66, 20.7, 20.8.20.12, 20.13, 20.14B, 20.15B
CANTILEVER SIGNS
ORIGINAL SCOPE:
10. STRUCTURES — SUMMARY AND MISC. TASKS AND DRAWINGS
10.86 Cost Estimate
10.11B Technical Meetings
10.12B Quality Assurance /Quality Control
10.14B Supervision
10.15B Coordination
18. STRUCTURES - MISCELLANEOUS
18.6 Overhead /Cantilever Sign Structure (Not applicable for this project)
19. SIGNING AND PAVEMENT MARKING ANALYSIS
19.5 Sign Panel Design Analysis
Establish sign layout, letter size and series for non - standard signs.
19.6 Sign Lighting /Electrical Calculations
Includes the verification of photometric on lighted signs, load center and voltage drop calculations.
19.7 Quantities
Includes all work required to determine the quantities of each plan sheet.
19.8 Computation Book
The CONSULTANT shall prepare the Computation Book. This includes all efforts required to develop the
Computation Book and the supporting documentation.
19.9 Cost Estimates
The CONSULTANT shall prepare the Engineer's Estimate of Probable Cost and provide with first
submittal. The Engineer's Estimate of Probable Cost shall be adjusted at each submittal to be maintained
until final submittal.
19.10 Technical Special Provisions
The CONSULTANT shall provide Technical Special Provisions for all items of work not covered by the
FDOT Standard Specifications for Road and Bridge Construction and recurring special provisions.
Standard Specifications, recurring special provisions and supplemental specifications should not be
modified unless absolutely necessary to control project specific requirements. The first nine sections of
the standard specifications, recurring special provisions and supplemental specifications shall not be -
8
Packet Page -1171-
2/26/2013 16.A.10.
modified without written approval of the COUNTY. All modifications to other sections must be justified
to the Project Manager to be included in the project's specifications package as Technical Special
Provisions.
The Technical Special Provisions shall provide a description of work, materials, equipment and specific
requirements, method of measurement and basis of payment. These provisions shall be submitted on 8-
1/2 "x11" sheets and shall not have holes punched or be bound in any way that would create a problem
for high volume reproduction.
19.12 Field Reviews
Includes all trips required to obtain necessary data for all elements of the signing and pavement marking
analysis.
19.13 Technical Meetings
Includes meetings with the COUNTY and other Agency staff, between disciplines, and CONSULTANT,
such as access management meetings, pavement design meetings, progress review meetings (phase
review), and miscellaneous meetings necessary for all elements of the signing and pavement marking
analysis.
19.14 Quality Assurance /Quality Control
The CONSULTANT shall be responsible for the professional quality, technical accuracy and coordination
of all surveys, designs, drawings, specifications and other services furnished by the CONSULTANT under
this contract.
19.16 Supervision includes all efforts required to supervise all technical design activities.
19.17 Coordination
Includes efforts to coordinate all elements of the Signing and Pavement Marking analysis of the project
to produce a final set of construction documents.
20. SIGNING AND PAVEMENT MARKING PLANS
The CONSULTANT shall prepare a set of Signing and Pavement Marking Plans in accordance with the
Plans Preparation Manual that includes the following.
20.113
Key Sheet
20.313
Tabulation of Quantities
20.4
General Notes /Pay Item Notes
20.613
Plan Sheets
20.7
Typical Details
20.8
Guide Sign Work Sheet(s)
20.12
Special Details
20.13
Interim Standards
20.14B
Quality Assurance /Quality Control
20.15B
Supervision
9
Packet Page -1172-
2/26/2013 16.A.10.
30A. GEOTECHNICAL
OUT OF SCOPE REQUEST:
Includes the design of 5 new cantilever signs per FDOT 90% comments.
Includes geotechnical services:
1. Execute a program of subsurface exploration consisting of subsurface sampling and field testing. We
will drill 1 Standard Penetration Test (SPT) borings to a depth of 40 feet at each overhead sign structure
location (5 total borings). The SPT borings will be performed with nearly continuous sampling for the
first 10 feet of depth and sampling every 5 feet thereafter.
2. Record groundwater levels during drilling.
3. Visually classify representative soil samples in the laboratory using the Unified Soil Classification
System. Identify soil conditions at each boring location and form an opinion of the site soil
stratigraphy. Perform limited laboratory testing on selected samples to assist in the classification.
4. Complete 1 FDOT Environmental Corrosion Series test on the most predominate soil stratum found
in each SPT boring.
5. Provide geotechnical engineering design criteria for the design of the drilled shaft foundations. Our
conclusions, and the information on which they are based, will be summarized in a written report
prepared by a professional engineer.
Per Marlene Messam's 1 -30 -2013 email —
We concur with FDOT's comments and believe the overhead cantilever signs are in the County's best
interest.
Dale A. Bathon, P.E.
Principal Project Manager
Signal & Lighting Operations and Maintenance Section
Capital Construction and Maintenance Section
Growth Management Division
239 - 252 -5827; Fax 239 - 252 -5868
Related FDOT 90% Comments and Responses:
31. A new overhead cantilever needs to be installed at station 1028 +00 in place of the advanced street
name sign.
The message for this overhead panel can be similar to one being removed sheet S -14. The advance
street name sign can be removed.
Reference: S -13
10
Packet Page -1173-
2/26/2013 16.A.10.
DAVID DOWLING
1/25/2013
CONSULTANT PM In lieu of a new cantilever sign for the interim condition of this intersection, we
recommend removing the existing cantilever sign structure (at Station 1030 +80 Rt.) and replacing it
1. With a ground mounted junction sign at Station 1026 +50 Rt.
2. And with a ground mounted destination sign at Station 1028 +50 Rt.
3. And with ground mounted trail blazer signs at Station 1030 +46 Rt. (for US41 NB) and at Station
1034 +86 Rt. (for US41 SB) per MUTCD Figure 2D -6.
In addition, Collier County prefers using the proposed advanced street name sign at Station 1028 +00
right.
BOB BRASWELL
REVIEWER An overhead structure would best facilitate this intersection and would give the best visibility
for motorist traveling this three lane section. In addition, it would also help eliminate lane switching.
With the volume of traffic expected at this intersection ground mounted sign would get blocked and not
be visible to traveling motorist. An overhead structure is also required by the 2013 Plans Preparation
Manual where there are three or more lanes (PPM Section 7.2.3) being utilized.
39. Remove sign number three. Remove the R6 -1R panel from the top of the R5 -1 assembly at Triangle
Boulevard.
Add R6 -1R and R6 -11- panels to the top of the stop assembly.
Reference: S -18
DAVID DOWLING
1/25/2013
CONSULTANT PM Collier County prefers using the proposed advanced street name sign (Sign #3).
We will remove the R6 -1R panel from the top of the R5 -1 assembly at Triangle Boulevard and add R6 -1R
and R6 -1L panels to the top of the stop assembly.
BOB BRASWELL
1/28/2013
REVIEWER I approved the correction mentioned. I reject with leaving in Sign number 3. This could be
signed more effectively with overhead sign as mention in comment 31.
40. Install a new overhead cantilever structure at station 1059 +60.00.
Reference: S -19
DAVID DOWLING
1/25/2013
CONSULTANT PM In lieu of a new cantilever sign for the interim condition of this intersection, we
recommend adding
1. A ground mounted junction sign at Station 1057 +50 Lt.
2. and a ground mounted destination sign at Station 1059 +50 Lt. and keeping the proposed ground
mounted trail blazer signs at Station 1053 +44 Lt. (for US41 NB) and at Station 1040 +76 Lt. (for US41 SB)
per MUTCD Figure 2D -6.
In addition we recommend using this approach for the east and west leg of US41 in lieu of new
cantilever signs for the interim condition of this intersection.
11
Packet Page -1174-
2/26/2013 16.A.10.
BOB BRASWELL
1/28/2013
REVIEWER See comment 31.
47. Install sign number 4 at station 2466 +80.
Reference: S -28
DAVID DOWLING
1/25/2013
CONSULTANT PM Sign #4 will not fit along the north side of US41 due to the limits of the canal and r/w
line.
BOB BRASWELL
1/28/2013
REVIEWER a mast arm similar to the existing will have to be installing to facilitate this sign at this
location.
REQUESTED COMPENSATION: $50,994 (Lump Sum)
TASK 4.4B, 4.513, 4.106, 4.116, 4.13, 4.1413, 4.156, 4.17B, 4.1813, 5.213, 5.36, 5.4 5.66 5.76 5.106
5.1513, 5.21, 5.2213, 5.236, 5.26, 6.7, 6.913, 6.1313, 6.1513, 6.17, 6.18, 6.196 6.218 6.228 10.513, 10.7C,
10.8C, 10.10, 10.11C, 10.12C, 10.14C, 10.15C, 18.12, 18.13, 18.14, 18.15, 18.16, 18.18 27 306 32.5
EAGLE CREEK NOISE AND PRIVACY WALLS
ORIGINAL SCOPE:
Change Order No. 3 for Contract No. 09 -5278; Sept. 13, 2011
The scope included structural design of sound barriers adjacent to the Eagle Creek subdivision since the
noise analysis indicated that sound barrier walls are required. A 21 foot high sound barrier wall was
designed north and south of Eagle Creek's entrance. The length of the south wall was 400 feet and the
length of the north wall was 400 foot.
10. STRUCTURES — SUMMARY AND MISC. TASKS AND DRAWINGS
10.5 Incorporate Report of Core Borings
10.7 Computation Book and Quantities
10.8 Cost Estimate
10.10 Field Reviews
10.11 Technical Meetings
10.12 Quality Assurance /Quality Control
10.14 Supervision
10.15 Coordination
18. STRUCTURES — MISC.
18.12 -18.18 SOUND BARRIER WALLS (GROUND MOUNT)
18.12 Horizontal Wall Geometry
18.13 Vertical Wall Geometry
18.14 Summary of Quantities — Aesthetics Requirements
12
Packet Page -1175-
2/26/2013 16.A.10.
18.15 Control Drawings
18.16 Design for Wall Height Covered by Standards
18.18 Aesthetics Details
Task 30 GEOTECHNICAL
Structural design of the sound barrier wall(s) are required adjacent to the Eagle Creek subdivision since
noise analysis indicates that a sound barrier wall(s) is required.
This will also require additional geotechnical exploration.
The purpose of this soils exploration is to determine the generalized soil and groundwater conditions in
the tested areas in order to provide foundation and overall site preparation recommendations.
This will be accomplished by the following:
1. Execute a program of subsurface exploration consisting of subsurface sampling and field testing.
Perform 3 Standard Penetration Test (SPT) borings to a depth of 30 feet. The SPT borings will be
performed with nearly continuous sampling for the first 10 feet of depth and sampling every 5 feet
thereafter.
2. Record groundwater levels during drilling.
3. Visually classify representative soil samples in the laboratory using the Unified Soil Classification
System. Identify soil conditions at each boring location and form an opinion of the site soil stratigraphy.
Perform limited laboratory testing on selected samples to assist in the classification.
4. Provide geotechnical recommendations for the sound wall foundations (i.e. bearing capacity and
estimated settlements) and site preparation. Summarize the conclusions, and the information on which
they are based, in a written report prepared by a professional engineer.
Task 32 NOISE IMPACT DESIGN ASSESSMENT
32.5 Noise Study Report
The CONSULTANT shall prepare a Reevaluation Noise Study Report as normally prepared during a PD &E
Study.
The CONSULTANT shall prepare a technical addendum to the Final Noise Study report due to the
anticipated public involvement required to finalize the design and placement of the noise walls. This is
required to allow the Reevaluation Noise Study Report to be finalized and sent to FHWA to obtain
approval and begin the final design and right of way acquisition phases. This technical addendum will
document the design and public involvement to reach the decision to design or not design the noise
walls. Contents may include the noise wall preliminary design sheets, aesthetic concepts, landscape
concepts and public coordination summary.
Following the public workshop, Stanley Consultants revised the design to include a 14 foot high sound
barrier wall on the south side only. No additional fee requested due to revising to a 14 foot.
OUT OF SCOPE REQUEST:
13
Packet Page -1176-
2/26/2013 16.A.10.
Stanley Consultants will redesign the north wall of approximately 400 feet at a new location to be
located on Eagle Creek's property. The wall height will be no more than 12 feet of exposed height and
placed on the existing berm where an existing 6 foot high wall currently is located. Engineering services
required include coordination (with Eagle Creek HOA, Architect, Residents, FDOT, and County), civil,
structural, quantity revisions, survey, field reviews, permitting, and geotechnical.
Stanley Consultants will add a gravity wall in front of the currently designed south wall and modify the
drainage and permits so that no more than a 12 foot high wall will be exposed. Engineering services
required include coordination (with Eagle Creek HOA, Architect, Residents, FDOT, and County), civil,
permitting, quantity revisions, field reviews, and drainage.
Stanley Consultants will update the noise study to include the results of the additional survey as directed
by FDOT.
4. ROADWAY ANALYSIS
4.4C Horizontal /Vertical Master Design Files
4.5B Cross Section Design Files
4.10B Computation Book and Quantities
4.118 Cost Estimate
4.13 Field Reviews
4.14C Technical Meetings
4.15C Quality Assurance /Quality Control
4.17C Supervision
4.18C Coordination
S. ROADWAY PLANS
5.2B Summary of Pay Items Sheets (Including Quantity Input)
5.3B Drainage Map Sheets
5.4 Typical Section Sheets
5.613 Summary of Quantities Sheets
5.7B Summary of Drainage Structures Sheets
5.10C Plan /Profile Sheets
5.15B Drainage Structure Sheets
5.21 Roadway Soil Sheets
5.22B Cross Sections
5.23B Conceptual Traffic Control Plan Sheets
5.26 Utility Adjustment Sheets
6. DRAINAGE ANALYSIS
6.7 Design of Stormwater Management Facility
6.913 Design of Storm Drains
6.138 Drainage Design Documentation Report
6.15B Cost Estimate
6.17 Field Reviews
6.18 Technical Meetings
6.19B Quality Assurance /Quality Control
6.21B Supervision
6.22B Coordination
14
Packet Page -1177-
2/26/2013 16.A.10.
10. STRUCTURES — SUMMARY AND MISC. TASKS AND DRAWINGS
10.5B Incorporate Report of Core Borings
103C Computation Book and Quantities
10.8C Cost Estimate
10.10 Field Reviews
10.11C Technical Meetings
10.12C Quality Assurance /Quality Control
10.14C Supervision
10.15C Coordination
18. STRUCTURES — MISC.
18.12 -18.18 SOUND BARRIER WALLS (GROUND MOUNT)
18.12 Horizontal Wall Geometry
18.13 Vertical Wall Geometry
18.14 Summary of Quantities — Aesthetics Requirements
18.15 Control Drawings
18.16 Design for Wall Height Covered by Standards
18.18 Aesthetics Details
27. SURVEY
Includes a supplemental survey of the new north wall location.
3013. GEOTECHNICAL
1. Execute a program of subsurface exploration consisting of subsurface sampling and field testing.
Perform 3 Standard Penetration Test (SPT) borings to a depth of 30 feet. The SPT borings will be
performed with nearly continuous sampling for the first 10 feet of depth and sampling every 5 feet
thereafter.
2. Record groundwater levels during drilling.
3. Visually classify representative soil samples in the laboratory using the Unified Soil Classification
System. Identify soil conditions at each boring location and form an opinion of the site soil stratigraphy.
Perform limited laboratory testing on selected samples to assist in the classification.
4. Provide geotechnical recommendations for the sound wall foundations (i.e. bearing capacity and
estimated settlements) and site preparation. Summarize the conclusions, and the information on which
they are based, in a written report prepared by a professional engineer.
32. NOISE IMPACT DESIGN ASSESSMENT
32.5 Noise Study Report
REQUESTED COMPENSATION: $59,620 (Lump Sum)
TASK 7.7 FPL / WATER MAIN ADJUSTMENTS
ORIGINAL SCOPE:
15
Packet Page -1178-
2/26/2013 16.A.10.
7. UTILITIES
7.7 Collect and Review Plans and Data from UAO(s)
CONSULTANT shall make determinations (Compensable Interest, Easements, Coordinate, and
Analyze); ensure information (utility type, material and size) is sent to the designer for inclusion
in the plans; and coordinate programming of funds.
• Collier County Utility Relocation Design
The CONSULTANT shall prepare engineering plan sheets that depict relocation of existing Collier
County Utilities as required, consistent with other sections of this scope. The plans will include
plan and profiles of proposed Collier County Utility lines, existing utilities, proposed roadway
and drainage improvements, standard details and be consistent with the maintenance of traffic.
Utility drawings will be reviewed by Collier County Utility staff prior to submittal for FDEP
permits.
OUT OF SCOPE REQUEST:
Attend meeting with FPL and Collier County to discuss the utility easement FPL desires at Triangle Blvd.
Adjust water main in plans, adjust tabulation of quantities, and update cost estimate.
REQUESTED COMPENSATION: $2,080 (Lump Sum)
TASK POST DESIGN SERVICES
ORIGINAL SCOPE:
3. POST DESIGN SERVICES
3.1 Bidding Services
• Participate in Pre -Bid Meetings
• Respond to bidder inquiries (if necessary)
• Provide Necessary plan revisions (if necessary)
• Time and Materials not to Exceed
3.2 Construction Services
• Participate in Construction Meetings
• Participate in Field Reviews
• Respond to Requests for Information (RFI)
• Evaluate proposed revisions
• Review Shop Drawings
• Coordinate with adjacent Development
• Revise plan drawings
• SFWMD Certification
• Time and Materials not to Exceed
i
Packet Page -1179-
3.3 Expenses
2/26/2013 16.A.10.
Copies, Mailing, shipping and delivery, Time and Materials not to Exceed
OUT OF SCOPE REQUEST:
Fee from the original contract did not include Post Design Services.
Post design may include final signed and sealed submittal package for bidding.
REQUESTED COMPENSATION: $100,000 (T &M NTE)
17
Packet Page -1180-
U
U
U
F
`u
U
0
0
u
Packet Page -1181-
2/26/2013 16.A.10.
= o
O
O u
c
�
u
_
°u a
«-
O
M
tr)
M
O
r-
O
G,
tr)
z z
Ou
O
.�
vi
69
•--�
64
.-�
EA
.�
69
-�T
if3
W)
bf3
vi
69
M
b9
W O
" �
c
E
a
a
o
4
V2'i S
p
C
E
$
�
E
3
V t
O
�
2
�
CL
-
C
z
0
�
�
N
m
O
d
O
Q
U'
m
4
n
S
ry
c
=
=
a
3
BOO
?
v
O
am
t
CL
a
N
c
W
e
z
No
M
Q
e
m
IA
p
O
S
V
a
Cn
m
O
m
b
N
l0
O
e
N
<
O1
r
16
O
N
m
e
V
0
o
E
L
-
e
I
o
-
O
^
16
V
r
16
d
$
z
N
N
O
w
g
a
m
d
N
z
v
ry
F
d
O
Q
c
C
N
m
CL
CL
m m $
Z
0
m
Q
o
vm
r
v
4
o
3
V
N
•'�
m W
v
c
�
Nf
r
ti W
ZQ
a
O
E
'
ry
p
m
* m
z
mm
e�
=
e
o
a
�
ry
m
e
Vt
T
�
V1
G
N N
N
CI
v C
Y1
N
00
O
tL
V
i
6
Y
NO
H
N
Q
L
E
Y
Y
Y
a
Y
Y
a
Y
Y
Y
o
1-
C
i
o
<
a
a
I
u
.a
O
O
O
O
O
O
O
O
dq
O
Packet Page -1181-
2/26/2013 16.A.10.
CHANGE ORDER
CHANGE NO. 5
TO: Ton Ahlschwede. Operations Manager
Stanley Consultants. Inc.
27300 Riverview Center Blvd.. STE 101
Bonita Springs. FL 34134
DATE: January 29. 2013
2/26/2013 16.A.10.
CONTRACT NO. 09-5278
BCC Date: 1/2612010
Agenda Item: 10B
PROJECT NAME: Design & Related Services for the Intersection Capacity Improvements to US41 &
SR/CR951 and 3R Roadway Improvements to SR951
PROJECT NO.: 60116
Under our AGREEMENT dated January 26, 2010
You hereby are authorized and directed to make the following change(s) in accordance with
terms and conditions of the Agreement: See Exhibit A - Supplemental Agreement #5
FOR THE (Additive) Sum of: $350.000.00 (Three Hundred and Fifty Thousand Dollars)
Original Agreement Amount
Sum of Previous Changes
This Change Order add
Present Agreement Amount
$1,700,000.00
$278.200.00
$350,000.00
$2.328.200.00
( � e a 's Phase I; calendar d due to this Chan
The time for completion shall be increased by 413 g
Order. Accordingly, the Contract Time is now 1,915 days calendar days. The substantial completion
date is April 9, 2015 and the final completion date is May 9, 2015. Your acceptance of this Change
Order shall constitute a modification to our Agreement and will be performed subject to all the same
terms and conditions as contained in our Agreement indicated above, as fully as if the same were
repeated in this acceptance. The adjustment, if any, to the Agreement shall constitute a full and final
settlement of any and all claims of the Contractor arising out of or related to the change set forth
herein, including claims for impact and delay costs.
IN WITNESS WHEREOF, the Contractor and the County have each, respectively, by an authorized person or
agent, hereunder set their hands and seals on the date(s) indicated below.
Accepted: , 20_
ATTEST: OWNER:
BOARD OF COUNTY COMMISSIONERS
COLLIER COUNTY, FLORIDA
Packet Page -1182-
Dwight E. Brock, Clerk
CONTRACTOR:
Stanley Consultants, Jnc.
I: �'1�17)l1/H%tf/itlll'i1/1,i11�-
Jon AhlicliweUe, Operations Manager
\J
Approved as to form and
Legal sufficiency:
Deputy County Attorney
Name
2/26/2013 16.A.10.
By:
Creorgia A. Hiller, -Esq., Chairwoman
By:'' ' ,C}.�Q.Qiyft_
Marlene Mess ,6' P.E., Project Manager
i
DEPARTMENT DIRECTOR
By:
Jay Ahmad .E.,
DIVISION DMINIST TOR
By:
Nfjck Casalanguida
Packet Page -1183-
aer COHYMY
AdminisUatrve Services Dvision
Ourchasing
® Contract Change Request
2/26/2013 16.A.10.
Purchasing Department
Change Modification Form
❑ Work Order Modification
Contract #:09-
Change #: 5
PO/Work Order #: 45-
Project Name:US41 & SR/CR 951
5278
$ 1,978;200=
00115819
Intersection and SR951 3R Im rov.
Project #: 60116
Project Manager:
Department: Transportation
Contractor /Firm Name: Stanley
Dollar Amount of this Change
Marlene Messam
Engineering
Consultants, Inc.
Original Contract/Work Order Amount
$ 1-,70G,;000.00
112612010
Original BCC Approval Date; Agenda Item #10E
Current BCC Approved Amount
$ 1,978;200=
9/1312011
Last BCC Approval Date; Agenda Item #16.A.1,
Current Contract/Work Order Amount
$ 1,°978,200.00
=W, 15
SAP Contract Expiration Date (Master)
Dollar Amount of this Change
$350,000:00
136.95%
Total Change from Original Amount
Revised Contract/Work Order Total
$2,328,200.00
17.697
Change from Current BCC Approved Amount
Cumulative Changes
$628,200.00
17.69%
Change from Current Amount
Completion Date, Description of the Task(s) Change, and Rationale for the Change
Original completion date: 2/8/2014
(Phase 1)
Last approved completion date:
March 22, 2014 (PH 1)
Revised completion date (includes this
change): May 9, 2015 (PH 1)
Number of days added : 413 -f,c
PkusC- I t-01 /
Each step on the contract modification checklist form has been reviewed prior to me
submitting for approval M.M. (this box must be initialed by Project Manager)
® Add new task(s)
® Change task(s)
❑ Delete task(s) ❑ Other (specify):
Revised: 5/16/12
1
Packet Page -1184-
L Provide a detailed and specific explanation of the requested change(s) to the task(s 2/26/2013 16.A.10.
days aaaea:
a. Task 4.4A, 4.5A,4.I OA, 4.1 1 A, 4.14A to 4.18A;5.2A to 5.10A to 5.14A, 5.22A- 5.26;6.9A,6.13A to
6.22A;,20.1A to 20.15A — Roadway Analysis & Plans, Drainage & Signing& marking (Bus stop,
enhancements) - $53,018.00 (Lump Sum)
During the 60% and 90% design review phase the Alternative Transportation Mode (ATM) Department
requested bus stop enhancements to be included in the design. The original scope of services did not
include future bus stops within the intersection segment of the project. These enhancements included new
bus stops concrete pads and bus pull outs locations on US41 eastbound and westbound and on CR 951
northbound and south bound. Long Range Transportation Plan, the ATM department determined that bus
services in these areas were necessary. These bus stop locations will have bus pull outs for safety and
closed bus shelters.
b. Task 4.4 to 4.18;5.2 - 5.26;6.7 - 6.22;10.5- 10.15;18.12 to 18.18; 27,30 & 32 — Roadway Analysis,
Plans, Structures, Geotechnical, Survey & Noise Study Report (update) — Eagle Creek Noise Wall -
$59,620.00 (Lump Sum)
The Eagle Creek Community qualified for a 21 -ft sound barrier to the north and south of their entrance on
SR951; however, this height of was unacceptable to the community. In attempting to provide a noise
barrier that met the FHWA criteria, it was discovered that only to the south of their entrance could a
shorter wall be constructed. The community has agreed to a shorter wall to the south of their entrance
provided that the aesthetics met the community's desires. These aesthetic enhancements will require the
design construction of a gravity wall and earth embankment in front of the noise wall. To provide the same
aesthetic continuity to the north of their entrance, the Community Eagle Creek asked that the County
design and construct a shorter wall on their property.
c. Task 10.1 to 10.4,10.7A to10.15A & 18.19 -18.22 — Structures (Light Pole Foundations) - $15,320.00
(Lump Sum)
The FDOT issued a new design memorandum for light pole foundations that will require the redesign of
the entire lighting system for the project. The FDOT District One who has final design oversight for this
project made the request during the 90% design phase. This could not have been anticipated in the original
scope of services and resulted in 8 additional detail sheets that need to be produced for the project.
d. Task 10.8B to 10.15B;18.6;19.5 to 19.17;20.1B to 20.15B;30A — Structures (Cantilever Sign
Structures) - $50,994.00 (Lump Sum)
At the 90% design review phase the FDOT requested that five (5) new cantilever signs structures to the
project.
e. Task 22.6 & 22.8 - Signalization Analysis and Plans (Interconnection Plans) - $13,196.00 (Lump
Sum)
New ITS CCTV cameras are needed on the northwest and southwest steel strain poles within in the US41
& SR/CR 951 intersection. As a result additional conduits and fiber are to be installed.
f. Task 29.1 to 29.3 Mapping (Right of Way) - $47,247.00 (Lump Sum)
Additional right of way documents are needed due to changes in the proposed project footprint. These right
of way documents include 47 additional sketched and legal descriptions; and, additional map sheets.
g. Post Design Services - $100,000.00 (Time and material not to Exceed)
At the time the design contract was negotiated the services normally included in the post design tasks such
as Bid Package, Shop Drawings, RFIs and SFWMD Project Certification were added to the scope of
services; however, the fee was not negotiated as part of the final design fees. This was due to the fact that
this nroiect was beins done as a Joint Participation Aereement with the FDOT and the level of effort ,-
Revised: 5/16/12
2
Packet Page -1185-
required to execute this task could not be quantified. Now that the project has reacl 2/26/2013 16.A.10.
level of design the effort for this task can be properly estimated.
Additional Design Scope of Services for Resurfacing, Restoration and Rehabilitation Improvements to SR951
Tntersection (Gas Taxes Funded)
Task 18.5;, 21.5- 21.19; 22.3 -22.17 – Structures Miscellaneous (Lighting on Signal Mast Arms) –
$10,605.00 (Lump Sum)
a. At the 30% design phase, a Lighting Justification Study was completed for this segment of CR 951
and concluded that there was no need for roadway lighting within the project limits. At the 90%
design review phase, the County's Traffic Operations Department requested that spot lighting be
included in the design at the intersection of Manatee Road and Collier Boulevard to enhance the
safety of the intersection. This work is considered beyond the original scope of services for this
segment of the roadway.
2. Provide detailed rationale for the requested change:
These changes are necessary design enhancements that were as a result of the County and FDOT staff review and
evaluation of the project.
3. Provide explanation why change was not anticipated in original scope of work:
The nature of these scope changes make it impossible for these changed to have been captured at the time of the
original scope of services development. Changes in state policies could not have been anticipated. The FDOT
provided original criteria for the design and they have final design oversight for this project. Also, some of the
changes were as a result of community public involvement.
4. Describe the impact if this change is not processed:
The Project needs Federal and State approval or risk losing funding. Also, by DCA the County has a commitment to
develop this project and not approving these changes would violate this commitment.
Type of Change / Modification
❑ 1. Planned / Elective
® 2. Unforeseen conditions /circumstance
❑ 3. Quantity or price adjustment
4. Correction of errors
® 5. Value added
I ❑ 6. Schedule adjustment
Change Requested By
Contractor /Consultant
Owner I ET—Using Department
❑ Desi n Professional
Qj Regulatory Agency (specify): I LJ Other 'specify):
Purchasing Profes16nal Participated4in Negotiation of Change / Modification: ❑ Yes No
Approve y:
Date:
aZ_jd'. i
Name and-Titlet Marlene Me 1-1 m, Sr.�,Project Manager
,
Reviewed b
Date:
Procurement ra gi s Name: on a Cummings
Revised: 5/16/12
3
Packet Page -1186-