Backup Documents 02/27/2018 Item #16C 5 ORIGINAL DOCUMENTS CHECKLIST & ROUTING SLIP i b
TO ACCOMPANY ALL ORIGINAL DOCUMENTS SENT TO
THE BOARD OF COUNTY COMMISSIONERS OFFICE FOR SIGNATURE
Print on pink paper. Attach to original document. The completed routing slip and original documents are to be forwarded to the County Attorney Office
at the time the item is placed on the agenda. All completed routing slips and original documents must be received in the County Attorney Office no later
than Monday preceding the Board meeting.
**NEW** ROUTING SLIP %avu-13f— 4-1, l21
Complete routing lines#1 through#2 as appropriate for additional signatures,dates,and/or information needed. If the document is already complete with the
exception of the Chairman's signature,draw a line through routing lines#1 through#2,complete the checklist,and forward to the County Attorney Office.
Route to Addressee(s) (List in routing order) Office Initials Date
1. Jennifer A. Belpedio, Esq., Asst. County Attorney 3,
County Atty. 957/l �
2. BCC Office Board of County -9
Commissioners c I A I�
3. Minutes and Records Clerk of Court's Office ? ck5 V7-.‘
yr/s/ Jz.,ktez,
PRIMARY CONTACT INFORMATION
Normally the primary contact is the person who created/prepared the Executive Summary. Primary contact information is needed in the event one of the
addressees above,may need to contact staff for additional or missing information.
Name of Primary Staff C. Perry Peeples Phone Number 239-252-8073
Contact/Department
Agenda Date Item was February 27,2018 Agenda Item Number 16-C-5
Approved by the BCC
Type of Document Underground Easement, Underground Number of Original
Attached Distribution Facilities Installation Documents Attached 7
Agreement with various attachments
PO number or account 474-173415-649030-59009.1 RECORDING FORM
number if document is ATTACHED
to be recorded
INSTRUCTIONS & CHECKLIST
Initial the Yes column or mark"N/A"in the Not Applicable column,whichever is Yes N/A(Not
appropriate. ) (Initial) Applicable)
1. Does the document require the chairman's original signature? o V CP
615
2. Does the document need to be sent to another agency for addition• signatures? If ye N/A
provide the Contact Information(Name;Agency;Address;Phone)on . .-. a s eet.
3. Original document has been signed/initialed for legal sufficiency. (All documents to be p�
signed by the Chairman,with the exception of most letters,must be reviewed and signed
by the Office of the County Attorney.
4. All handwritten strike-through and revisions have been initialed by the County Attorney's
Office and all other parties except the BCC Chairman and the Clerk to the Board
5. The Chairman's signature line date has been entered as the date of BCC approval of the N/A
document or the final ne otiated contract date whichever is applicable.
6. ••ed on the appropriate pages indicating where the Chairman's CPP
signature and Mitials are equired.
7. In most cases(some contracts are an exception),the original document and this routing slip N/A
should be provided to the County Attorney Office at the time the item is input into SIRE.
Some documents are time sensitive and require forwarding to Tallahassee within a certain
time frame or the BCC's actions are nullified. Be aware of your deadlines!
8. The document was approved by the BCC as stated above and all changes made CPP
during the meeting have been incorporated in the attached document. The County
Attorney's Office has reviewed the changes,if applicable.
9. Initials of attorney verifying that the attached document is the version approved by the
BCC,all changes directed by the BCC have been made, and the document is ready for -
Chairman's signature.
I:Forms/County Forms/BCC Forms/Original Documents Routing Slip WWS Original 9.03.04,Revised 1.26.05,Revised 2.24.05;Revised 11/30/12
16C 5
Memorandum
TO: Minutes & Records Management
FROM: C. Perry Peeples, Real Property Management
DATE: February 27, 2018
RE: North East Recycling Drop-off Center— FPL Easement
On February 27, 2018, the BCC approved Agenda Item 16.C.5, approving the Underground
Easement to FPL and authorizing the Chairman to execute the Easement, Underground
Distribution Facilities Installation Agreement and appurtenant documents.
Attached are the original Underground Easement, Underground Distribution Facilities
Installation Agreement and appurtenant documents for attestation. Please attest to
Commissioner Solis' signature as Chairman on the documents and return a copy of the
attested documents to the email address below.
After attesting to the Chairman's signature on the Underground Easement, please record the
Underground Easement using the recording form attached.
Please contact me if you have any questions or comments at Extension 8073 or
perrypeeples@colliergov.net.
Thank you.
INSTR 5520527 OR 5484 PG 1282
RECORDED 3/712018 10:58 AM PAGES 4
DWIGHT E. BROCK, CLERK OF THE CIRCUIT COURT
COLLIER COUNTY FLORIDA
DOC@.70$0.70 REC$35.50
UNDERGROUND EASEMENT
(BUSINESS)
Work Request No. 5618445 Prepared By:
Sec. 13,Twp 48S, Rge 27E Name: Anna Smith Bradley
Parcel I.D.:00209961005 Co. Name: FP&L Co.
(Maintained by County Appraiser) Address: 1220 5th Ave. N.
Naples, Florida 34102
The undersigned, in consideration of the payment of $1.00 and other good and valuable consideration,
the adequacy and receipt of which is hereby acknowledged, grant and give to Florida Power & Light
Company, its licensees, agents, successors, and assigns ("FPL"), a non-exclusive easement forever for the
construction, operation and maintenance of underground electric utility facilities (including cables,
conduits, appurtenant equipment and appurtenant above ground equipment) to be installed from time to
time;with the right to reconstruct, improve, add to, enlarge, change the voltage, as well as, the size of and
remove such facilities or any of them within an easement described as follows:
See Exhibit"A"("Easement Area")
Together with the right to permit FPL to attach wires to any facilities hereunder and lay cable and conduit
within the easement and to operate the same for FPL's communications purposes; the right of ingress and
egress to the Easement Area at all times; the right to clear the land and keep it cleared of all trees,
undergrowth and other obstructions within the Easement Area; the right to trim and cut and keep trimmed
and cut all dead, weak, leaning or dangerous trees or limbs outside of the Easement Area which might
interfere with or fall upon the lines or systems of communications or power transmission or distribution; and
further grants, to the fullest extent the undersigned has the power to grant, if at all, the rights hereinabove
granted on the Easement Area heretofore described, over, along, under and across the roads, streets or
highways adjoining or through said Easement Area.
IN WITNESS WHEREOF, the undersigned has signed and sealed this instrument on this / day of
IcLruar,� , 2018.
Board of Co ty C.• missioners
Collier Co ty, FI• Ida
By: . A .�
ANDY SOLIS, Chairman
3335 Tamiami Trail East, Suite 101
Naples, Florida 34112
Attest:
Dwight E. Brock, Cierk
By: Alai hiltafiri,, THIS CONVEYANCE ACCEPT Y
THISBOAROFC ED a THE
Print: r _ 144. . , COLLIER C COUNTY COMMISSIONERS,
Deputy Clerk COUNTY, FLORIDA.
Atf- t as to Chairman's bATEDPURSUANT TO ENo TEM NO. �b C• �.
signatureonly.
Approved as to form and legality:
—
Jennifer A. Belpedio, Asigt County Attorney
C)31
OBJ
16C 5
s Li 1 1 , '_ CHLINE SH cri J J
-1,4,,. , ii I
jiT111� PARCEL BO NDA Y I1
- (NO RECORDING FOUND IN PUBLIC; _;
4411111e4'
:: RECORDS OF COLLIER COUNTY)rifilitilek*
0 25 50 100 `. .'♦.•�
(INTENDED DISPLAYSCALE: 1"=100') ,,.4Wit•�. ''.`i,
•ROPUSED FL.'I.• •• ' &
PARCEL No. 00209840003 PARCEL No. 00209961005 LIGHT COM-AN A , NT/
\ / COLLIER COUNTY y
COLLIER COUNTYX (ORB 3328, PG 2428)(ORB 1439, PG 925) l
PROPOSED NE RECYCLING
DROP-OFF CENTER �i
EXR=488.01'
A=88°26'32"
CB=N43 4812 E
C=680.70'
P.0 B. L=753 •' /
1 R=498.01'
A=89°37'53"
N89°.5'513"E 10.11 C=702.02'3 52 W
N8934'41 E 5.20'
N0025'19'W 5.05' L L=779.06'
P.D.C. 11
NORTHEAST CORNER L-II
OF TRACT "Er,
ES WATERWAYS OF NAPLES, �``_- LINE TABLE
N UNIT SEVEN
°° m
(PB 36, PG 72) LINE BEARING DISTANCE
o (Di— L1 NOO'04'07"W 77.98'
zv
PARCEL No. 81216080040 " �u
N WATERWAYS OF NAPLES HOMEOWNERS W I orn L2 SO0'04'07"E 67.75'
ASSOCIATION INC CO
3 (ORB 3976, PG 803) L.. O N PARCEL No. 00209961005 L3 NO0'25'04"W 387.85'
o O W O COLLIER COUNTY
-
o TRACT "B" ? (9) (ORB 3328, PG 2428)
v) WATERWAYS OF NAPLES Q -i L4 SOO'25'04"E 387.85'
UNIT SEVEN CO
I (PB 36, PG 72) W
u
✓
N
I I HEREBY CERTIFY, TO THE BEST OF MY KNOWLEDGE
AND BELIEF, THAT THE LEGAL DESCRIPTION AND NOTES:
ATTACHED SKETCH WERE PREPARED IN ACCORDANCE
O WITH THE APPLICABLE PROVISIONS OF CHAPTER 1. BEARINGS SHOWN HEREON ARE PROJECTED ONTO THE
5J-17.05, FLORIDA ADMINISTRATIVE CODE, PURSUANT FLORIDA STATE PLANE COORDINATE SYSTEM, EAST ZONE
- TO CHAPTER 472, FLORIDA STATUTES. AND BASED ON THE EAST LINE OF TRACT "B", PLAT OF
WATERWAYS OF NAPLES, WHEREIN SAID EAST LINE BEARS
i
S.0025'19"E.
2. THIS SKETCH DOES NOT MAKE ANY REPRESENTATION AS TO
Y ZONING OR DEVELOPMENT RESTRICTIONS ON THE SUBJECT
• BARRY E. SYREN (FOR THE FIRM L.B. 642) PARCEL.
T PROFESSIONAL SURVEYOR AND MAPPER 3. PARCEL CONTAINS 19,716 SQUARE FEET (0.45 ACRES) MORE OR
o FLORIDA CERTIFICATE NO. 5365LESS.
4. P.0 C. = POINT OF COMMENCEMENT
a• DATE SIGNED: 5. P.O.B. = POINT OF BEGINNING
O 6. ORB = OFFICIAL RECORDS BOOK
NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL 7. PB = PLAT BOOK
• RAISED SEAL OF FLORIDA LICENSED SURVEYOR 9. NOT VALID WITHOUT SHEETS 1 THROUGH 3 OF 3.
6 AND MAPPER.
JOH1\O N JOHNSON ENGINEERING, INC. SKETCH TO ACCOMPANY DESCRIPTION
2350 STANFORD COURT SECTION 13,TOWNSHIP 48 SOUTH, RANGE 27 EAST
NAPLES, FLORIDA 34112 COLLIER COUNTY, FLORIDA
PHONE: (239) 434-0333
FAX: (239) 334-3661
ENGINEERING E.B. #642 & L.B. #642 DATE PROJECT NO. FILE NO SCALE SHEET
12-12-17 120149700-117 13-48-27 I 1"=100' 1 OF 3
16 C 5
11- 77-
r
PARCEL No. 00209961005
COLLIER COUNTY
(ORB 3328, PG 2428) \ )
er PROPOSED NE RECYCLING
DROP-OFF CENTER
I1
_
•
„ G
/' 4°50E 181.06' //.
S85°16'14"W 1032 r
,& S84°50'29"W 171.25 / S 4°22'41"E 73.63'
N76°31'30"W 116.89' ��1*
°' v N52}°22'4c'W 65,3° d'
_o
o W PROPO ED FLORIDA PO FL& — I ( R=274.OG1' R=264.00'
co I-rn OCO LIGHT [yOMPANY Et. NT — • i'L1=9°39'01" ' A=10°59'19"
04 o a N N J - B'=N4°24'26"E CB=S5°04'35"W
o"m o • — CJ46.Os' C=50.55'
�M o O
Z_ , Z co L7 — L. L='6.1 L=50.63'
o o 1�Li i —
I ' L5 _ ' '
En /�' I
o
n o
N j 0 00
N
01 f-N
o ..lilt IL. ON=O
N8 OO d
DU
m . co ce
4CO ow
U
o I Ll l Z J_J O
-0 IJJ I 0 0C
U
$ is O < O
Q
N
0
3 J. w O
n r
oN 3 3 - I /
PARCEL BOUNDARY
- I I (NO RECORDING FOUND
1 G.
= I I C r, INCOLLIER PUBLIC RECORDS OF
B COUNTY)
ATCH NES U
� 1
o
o V LSI
Qn
LINE TABLE
LINE BEARING DISTANCE
.-:5,
L5 N90°00'00"W 44.80'
Ek A
B L6 S00°00'00"E 20.00' gel2 1
L7 N90°00'00"E 34.65' 11
N
a 0 25 50 100
O 1 ,
o*NOT VALID WITHOUT SHEETS 1 THROUGH 3 OF 3. (INTENDED DISPLAY SCALE: 1"=100')
O HN_
S n JOHNSON ENGINEERING, INC. SKETCH TO ACCOMPANY DESCRIPTION
T A 2350 STANFORD COURT SECTION 13,TOWNSHIP 48 SOUTH, RANGE 27 EAST
J NAPLES, FLORIDA 34112
PHONE: (239) 434-0333 COLLIER COUNTY, FLORIDA
FAX: 334-3661
ENGINEERING E.B. #642642 & L.B. #642 DATE PROJECT NO. FILE NO. SCALE SHEET
12-12-17 20149700-117 13-48-27 1"=100' 2 OF 3
16C 5
DESCRIPTION
A PARCEL OF LAND
LYING IN
SECTION 13, TOWNSHIP 48 SOUTH, RANGE 27 EAST
COLLIER COUNTY, FLORIDA
A TRACT OR PARCEL OF LAND LYING IN SECTION 13, TOWNSHIP 48 SOUTH, RANGE 27 EAST,
COLLIER COUNTY, FLORIDA, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:
COMMENCING AT THE NORTHEAST CORNER OF TRACT "B", WATERWAYS OF NAPLES UNIT 7, AS
RECORDED IN PLAT BOOK 36, PAGE 72, OF THE PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA,
THENCE N.00'25'19"W. ALONG THE NORTH PROLONGATION OF THE EAST LINE OF SAID TRACT "B",
A DISTANCE OF 5.05 FEET; THENCE N.89'34'41"E. DEPARTING SAID NORTH PROLONGATION, A
DISTANCE OF 5.20 FEET TO THE POINT OF BEGINNING.
FROM SAID POINT OF BEGINNING, THENCE N.89'55'53"E., A DISTANCE OF 10.00 FEET; THENCE
S.00'O4'07"E., A DISTANCE OF 67.75 FEET TO A POINT ON A NON-TANGENTIAL CURVE TO THE
LEFT; THENCE ALONG SAID CURVE TO THE LEFT HAVING A RADIUS OF 488.01 FEET (CHORD
BEARING N.43'48'12"E.) (CHORD 680.70 FEET) (DELTA 88'26'32") FOR A DISTANCE OF 753.29
FEET TO THE POINT OF TANGENCY OF SAID CURVE; THENCE N.00'25'O4"W., A DISTANCE OF
387.85 FEET TO A POINT OF CURVATURE TO THE RIGHT; THENCE ALONG SAID CURVE TO THE
RIGHT HAVING A RADIUS OF 274.00 FEET (CHORD BEARING N.04'24'26"E.) (CHORD 46.09 FEET)
(DELTA 09'39'01") FOR A DISTANCE OF 46.15 FEET; THENCE N.54'22'41"W., A DISTANCE OF
65.39 FEET; THENCE N.76'31'3O"W., A DISTANCE OF 116.89 FEET; THENCE S.85'16'14"W., A
DISTANCE OF 103.25 FEET; THENCE S.84'50'29"W., A DISTANCE OF 171.25 FEET; THENCE
S.00'27'49"W., A DISTANCE OF 134.42 FEET; THENCE N.9O'OO'OO"E., A DISTANCE OF 34.65 FEET;
THENCE S.00'OO'OO"E., A DISTANCE OF 20.00 FEET; THENCE N9O'OO'0O"W., A DISTANCE OF 44.80
FEET; THENCE NOO'27'3O"E., A DISTANCE OF 163.56 FEET; THENCE N84'50'35"E., A DISTANCE OF
181.06 FEET; THENCE N.85'16'14"E., A DISTANCE OF 104.18 FEET; THENCE S.76'31'3O"E., A
DISTANCE OF 120.45 FEET; THENCE S.54'22'41"E., A DISTANCE OF 73.63 FEET TO A POINT ON A
NON-TANGENTIAL CURVE TO THE LEFT; THENCE ALONG SAID CURVE TO THE LEFT HAVING A
RADIUS OF 264.00 FEET (CHORD BEARING 5.05'04'35"W.) (CHORD 50.55 FEET) (DELTA 10'59'19")
FOR A DISTANCE OF 50.63 FEET; THENCE 5.00'25'04"E., A DISTANCE OF 387.85 FEET TO A
POINT OF CURVATURE TO THE RIGHT; THENCE ALONG SAID CURVE TO THE RIGHT HAVING A
a
N RADIUS OF 498.01 FEET (CHORD BEARING S.44'23'52"W.) (CHORD 702.02 FEET) (DELTA
89'37'53") FOR A DISTANCE OF 779.06 FEET; THENCE N.00'O4'O7"W., A DISTANCE OF 77.98
0
FEET TO THE POINT OF BEGINNING.
N
CONTAINING 19,716 SQUARE FEET OR 0.45 ACRES, MORE OR LESS.
BEARINGS SHOWN HEREON ARE PROJECTED ONTO THE FLORIDA STATE PLANE COORDINATE
SYSTEM, EAST ZONE AND BASED ON THE EAST LINE OF TRACT "B", PLAT OF WATERWAYS OF
NAPLES, WHEREIN SAID EAST LINE BEARS 5.00'25'19"E.
3
a
0
U,
t
N
O
O
O
EXHiI3 '... -
t _ f 3
0
0
a
0
N
d
O
o*NOT VALID WITHOUT SHEETS 1 THROUGH 3 OF 3.
O T T JOHNSON ENGINEERING, DESCRIPTION
J lulN S 0111 2350 STANFORD COURT SECTION 13,TOWNSHIP 48 SOUTH, RANGE 27 EAST
NAPLES, FLORIDA 34112 COLLIER COUNTY, FLORIDA
PHONE: (239) 434-0333
ENGINEERING FAX: (239) 334-3661 DATE PROJECT NO FILE NO. SCALE SHEET
E.B. #642 & L.B. #642
12-12-17 20149700-117 13-48-27 N/A 3 OF 3
16C 5
Wit r, 5618445
R7I9
FPL
Form 360 Res. 1/09/12
UNDERGROUND DISTRIBUTION FACILITIES INSTALLATION AGREEMENT
This Agreement, made this _14-"lay of , 2017, by and between Collier County (hereinafter called the Customer) and
FLORIDA POWER & LIGHT COMPANY, a co ration organized and existing under the laws of the State of Florida (hereinafter
called FPL).
111 I NESSCTII
Whereas,the Customer has applied to fPI for underground distribution facilities hi he installed on Customers property known as t'IFRIX'located on 39th Ave NE in
Collier,Florida.
That for and in consideration of the covenants and agreements herein set forth,the parties hereto covenant and agree as follows
I. The Customer shall pay FPL a Contribution in Aid of Construction of 527.645.60(the Contribution)to cover the differential cost between an underground and an
overhead system. This is based on the currently effective tariff filed with the Florida Public Service Commission by FPl
2 That a credit ofn shall be provided to the Customer for trending.backfilling.installation of Company provided conduit and other work,as shown on Exhibit ll
if applicable,and approved by FPI. If such credit applies,the resulting Contribution cash payment shall be SQ
3 The contribution and credit are subject to adjustment when FPL's tariff is revised by the Florida Public Service Cormisaon and the Customer has requested FPI
to delay FPI.'s scheduled date of installation.Any additional costs caused by a Customer's change in the Customer's plans submitted to FPL on which the
contribution was based shall be paid for by the Customer The contribution does not include the cost of conversion of any existing overhead lines to underground
or the relocation of any existing overhead or underground facilities to serve the property identified above
4 That the Contribution provides for 277/480 V,three phase(120/240 volt,single phase for URD Subdivisions)underground electrical service with facilities
located on private property in easements as required by FPL The contribution is based on employment of rapid production techniques and cooperation to
eliminate conflicts with other utilities Underground service,secondary,and primary conductors are to be of standard FPI design,in conduit,and with above-
grade appurtenances
5 That the payment of the Contribution does not waive any provisions of FPI's Electric Tariff
If the property is subject to an underground ordinance,FPL shall notify the appropriate governmental agency that satisfactory arrangements have been made with
the Customer as specified by FPI.
rifle to and ownership of the facilities installed as a result of this agreement shall at all limes remain the property of FPL
6 That good and sufficient easements,including legal descriptions and survey work to produce such easements,and mortgage subordinations required by FPL for
the installation and maintenance of its electric distribution facilities must be granted or obtained,and recorded,at no cost to FPL,prior to trenching,installation
and/or construction of FPI facilities FPL may require mortgage subordinatuons when the Customer's property,on which FPL will install Its facilities,is
mortgaged and(I)Gere are no provisions in the mortgage that the lien of the mortgage will be subordinate to utility easements,(2)FPL's easement has not been
recorded prior to the recordation of the mortgage,(3)FPL's facilities are or will be used to serve other parcels of property,or(4)other circumstances exist which
FPI.determines would make such a subordination necessary
a) The Customer shall furnish FPL a copy of the deed or other suitable document,which contains a full legal description,and exact name of the legal owner to
be used when an easement is prepared,as required by FPI.
b) The Customer shall furnish drawings satisfactory to FPL,showing the location of existing and proposed structures on the C'ustomer's constniction site,as
required by FPL
e) Should for any reason,except for the sole eror of FPI„FPL's facilities not be constructed within the easement.FPI.may require the customer to grant new
easements and obtain any necessary mortgage subordinatlons to cover Fig.'s installed facilities,at no cast to FPI,and FPL will release the existing
casement. Mortgage subordination,'will be necessary in this context when:
I) the Customer's property out which FPL will install its facilities is mortgaged,
2) there are no provisions in the mortgage for subordination of the lien of the mortgage to utility casements,or
3) FPI's facilities are or will be used to serve other parcels of property.
7 Before FPL can begin its engineering work on the underground electric distribution facilities,the Customer shall provide FPI.with the following
al Paving,grading.and drainage plans showing all surface and subsurface drainage satisfactory to FPL,
b) A construction schedule,
c) An estimate of when electric service will be required,and
d) Copies of the Customer's final construction plans as well as other construction drawings(plot,site,sewage,electrical,etc)requested by FPL plats provided
by the Customer must be either recorded by the circuit clerk or other recording officer or prepared and certified as meeting the requirements for recording
(except approval by the governing body)by a registered land surveyor
16C 5
WR It 5618445
R7I9
FPL
8.Prior to FPL construction pursuant to this agreement,the Customer shall
a) Clear the FPI.easement on the Customer's property of tree stumps all trees,and other obstructions that conflict with construction,including the drainage of
all flooded areas The Customer shall be responsible for clearing,compacting.boulder and large rock removal.stump removal,paving and addressing other
special conditions 'The casement shall be graded to within sic inches of final grade with soil stabilized
hi Pmvide property line and comer stakes,designated by a licensed surveyor,to establish a reference for locating the underground cable trench route in the
easement and additional reference points when required by FPL Also,the Customer shall provide stakes identifying the location,depth,size and type
facility of all non-FPI underground facilities within or near the easement where FPI distribution facilities sill be installed The Customer shall maintain
these stakes,and if any of these stakes are lost,destroyed or moved and FPL requires their use,the Customer shall replace the stakes at no cost to 1'Pl
unless the stakes arc lost,destroyed nr moved by an aeent.employee.contractor or subcontractor of FPI,in which case FPI.will pay the Customer the cost
of replacing the stakes
c) It is further understood and agreed that subsequent relocation or repair of the FPI system,once installed,will be paid by the Customer if said relocation or
repair is a result of a change in the grading by the Customer or any of the('mimic-es contractors or subcontractors from the time the underground facilities
were installed:and,that subsequent repair to FPL's system,once installed,will he paid by the Customer if said repair is a result of damage caused by the
Customer or any of the C'ustomer's contractors or subcontractors.
d) Provide sufficient and tinily advance notice(S,¢days)as required by FPI.,for FPL to install its underground distribution facilities prior to the installation of
paving,landscaping,sodding,sprinkler systems,or other surface obstructions In the absence of sufficient coordination,as determined by FPL,by the
Customer,all additional costs for trenching and backfilling shall be paid by the Customer,and none of the costs of restoring paving,landscaping,grass
sprinkler systems and all other surface obstructions to their original condition,should they be installed prior to f Pl.'s facilities,shall be borne by FPI.
e) Pay for all additional'oats incurred by FPL which may include,but are not limited to,engineering design,administration and relocation expenses,due to
changes made subsequent to this agreement on the subdivision or development layout or grade
f) Provide applicable trenching.backfilling installation of Company provided conduit and other work in accordance with IPL specifications more particularly
described on Exhibit I3 attached hereto At the discretion of FPL.either correct any discrepancies,within two(2)working days,found in the installation that
are inconsistent with the instructions and specifications attached to this agreement or pay the associated cost to correct the installation within thirty(30)days
of receiving the associated hill,and in either case,reimburse FPL for costs associated with lost crew time due to such discrepancies
g) Provide a meter enclosure,downpipe and ell which meet all applicable codes and FPI.specifications and which will accommodate FPL's service cable sire
and design. 'These items must be confirmed with FPL prior to purchase FPL will not be responsible for costs involved in modifying or replacing items
which do not meet the above criteria
9.FPL shall
a) Provide the Customer with a plan showing the location of all FPI,underground facilities,point of delivery,and transformer locations and specifications
required by FPI.and to he adhered to by the Customer
Is) Install,own,and maintain the electric distribution facilities up to the designated point of delivery except when otherwise noted
c) Request the Customer to participate in a pre-construction conference with the Customer's contractors,the FM representatives and other utilities within six
(6)weeks of the start of crostniction At the pre-construction conference,FPL shall provide the Customer with an estimate of the date when service may be
provided.
10. This Agreement is subject to FPL's Electric Tariff.including bin not limited to the General Rules and Regulations for Electric Service and the Rules of the Florida
Public Service Commission,as they arc now written,or as they may be revised,amended or supplemented
1 I. This agreement shall inure to the benefit of,and be binding upon,the successors and assigns of ' Customer and FI'I
The Customer and FPL will coordinate closely in fulfilling obligations in order to avoid delays in p .ing pe • ' nt electric se ' c c of the C'ustomer's receipt of
a ccniflcate of occupancy. /
e /
Aepted s,
Accepted i A / ._ • Z i2"7 tAt •
MrZer" u�'. -Cr- (Date)
July 7.2017
For FPL (Date) �— - -(Date)
Wness ' (petal
r--7-E (•l\-4:\
LfGG
moi:
Pi1CHT E..•aROCK;CI*tk�
4, Approved as to form and legality
r; ; �.i'�.. _ ion 4.64.11,00 -
Attest as to Chairman's
As ant County At curvy ��b A
signature only. .\_,
16C 5
WR rt 5618445
8719
FPL
UNDERGROUND ROAD/PAVEMENT CROSSING AGREEMENT
This Agreement,made this 14:/lay of 14%4 ,2017,by and between Collier County(hereinafter called the Customer)and
Florida Power& Light Company,a corporation rganized and existing under the laws of the State of Florida(hereinafter called FPL)
WHEREAS the Customer has requested the pre-approval of the location and installation of underground distribution facilities to be
located in a described FPI.easement provided by the Customer.
Project Name:NERDC
WITNESSETH
That,for and in consideration of the covenants and agreements herein set forth,the parties hereto covenant and agree as follows:
1.The Customer shall:
a) Install conduit,cable markers,and associated materials provided by FPL.in accordance with the instructions and
specifications attached to this Agreement;
b) be solely responsible for the installation of conduit at the correct location and the correct depth pursuant to the FPL
construction drawings and specifications;
c) assume liability for any delays and/or additional costs to FPL caused by a conduit installation that is not consistent
with the instructions and specifications attached to this Agreement;
d) assume liability for materials lost,stolen,or damaged once the Customer receives the material;
e) provide reasonable notification of the conduit installation date and allow FPL to inspect the conduit installation
prior to backfilling the trench created for the underground distribution facility;
f) at the request of FPL,correct any discrepancies,within two(2)working days,found in the installation that are
inconsistent with the instructions and specifications attached to this Agreement,or pay FPL the associated cost to
correct the installation within thirty(30)days of receiving the associated bill,and in either case,
reimburse FPL for costs associated with lost crew time due to such discrepancies;
g) provide survey control points for FPL to stake the road/pavement crossing;
h) provide"as built"prints within two(2)weeks of final installation,and
i) provide for pick-up of materials.
2. FPL shall:
a) provide instructions and specifications for the installation of FPL-provided conduit;
b) provide conduit,cable markers,and required materials to the Customer for the installation of underground facilities
at the specified road/pavement crossing;
c) provide staking for the Customer at the specified road/pavement crossing;
O
16C 5
WR II 5618445
R719
FPL
d) inspect the underground distribution facilities prior to the backfilling of the trench to insure proper installation of
said facilities;
e) furnish any additional material at the current cost plus applicable loading and delivery charges;
apply a credit in the amount of SO in the event that the Customer has made or has agreed to
make a contrihution in aid of construction for other underground distribution facilities associated with this
Agreement;
g) assume no liability for materials lost,stolen,or damaged once received by the customer;
h) assume no liability for delays caused by delivery deficiency, including,but not limited to,insufficient,lost,stolen.
or damaged material;
i) assume no liability for delays because of misunderstanding of installation drawings or specifications;
j) assume no liability for delays or additional cost caused by an inadequacy of the conduit system installation,and
k) assume no liability for special incidental or consequential damages of any nature.
3 This agreement is subject to FPL's General Rules and Regulations for Electric Service and the Rules of the Florida Public Service
Commission,
5. hjeci' 4-r) 44,e 1,.,n-at',cNst set re,f4t-• , Sec va -76,46 Q.% , 4=1 �. da
4.Customer agrees to protect,defend, indemnify and hold FPL,its officers,directors,employees,and agents(FPL Entities)free and'>} Jt,
unharmed from and against any and all claims,liabilities,loss,costs,or damages whatsoever,related to any claim made by tenants, • r.
invites,guests,any other or third parties,including court costs and attorney's fees,whether or not due to or caused in whole or part by
the negligence of FPL Entities,resulting from or in connection with the performance of this Agreement by either party hereto,
afpltc. re
IN WITNESS WHEREOF the parties hereto have caused the Agreement to be duly executed to be effective as of the day and year
first written above:
APPLICANT: FPL:
CL"
SIGNEDSIGNED
Andy Solis
NAME_ __ NAME_ _ Anna Smith Bradley
Chairman
'TITLE TTILE Associate Engineer
Approved as to form and legality i s i iT E. t3. OL i, C;lEri<
Aant County t ncy Attest as to Chairman's
3 c‘ signature only. _ ci co,
5/2618
2r
16C 5
WR n 5618445
R719
FPL
NOTIFICATION OF FPL FACILITIES
Customer/Agency:Collier County Date of Meeting/Contact:July 7.2017
Developer/Contractor Name:Sue Zimmerman Project Number/Name:NERDC
I.ocation of Project:39th Ave NE City:CollierPhone:239-947-7374
FPI.Representative:Anna Smith Bradley Phone:239-947-7374
Developer/Contractor Representative:Sue Zimmerman FPL Work Request 8/Work Order 4:5618445
FPI.calls your attention to the fact that there may he energized,high voltage electric lines,both overhead and underground.located in the area of this
project. It is imperative that you visually survey the area and that you also take the necessary steps to identify all overhead and underground facilities
prior to commencing construction to determine whether the construction of any proposed improvements will bring any person. tool. machinery.
equipment or object closer to FPI's power lines than the OSIIA-prescribed limits. If it will,you must either re-design your project to allow it to he built
safely given the pre-existing power line location, or make arrangements with FPL. to either deenergi,e and ground our facilities. or relocate them,
possibly at your expense. You must do this before allowing any construction near the power lines. It is impossible for FPI to know or predict
whether or not the contractors or subcontractors,and their employees,will operate or use cranes,digging apparatus or other mobile equipment,or handle
materials or tools,in dangerous proximity to such power lines during the course of construction,and,if so.when and where. Therefore,if it becomes
necessary for any contractor or subcontractor,or their employees,to operate or handle cranes,digging apparatus.draglines.mobile equipment,or any
other equipment,tools or materials in such a manna that they might come closer to underground or overhead power lines than is permitted by local.state
or federal regulations,you and any such contractor or subcontractor must notify FPI.in writing of such planned operation prior to the commencement
thereof and make all necessary arrangements with FPL in order to carry out the work in a safe manner. Any work in the vicinity of the electric lines
should be suspended until these arrangements are finalized and Implemented.
The National Electrical Safety Code("NES('") prescribes minimum clearances that must be maintained If you build your structure so that those
clearances cannot be maintained,you may he required to compensate FPI.for the relocation of our facilities to comply with those clearances. As such.
you should contact FPL prior to commencing construction near pre-existing underground or overhead power lines to make sure that your proposed
improvement does not impinge upon the NESC clearances.
It is your responsibility and the responsibility of your contractors and subcontractors on this project to diligently fulfill the following obligations:
I. Make absolutely certain that all persons responsible for operating or handling cranes,digging apparatus,draglines,mobile equipment or any
equipment,tool,or material capable of contacting a power line.are in compliance with all applicable state and federal regulations,including
but not limited to U.S.Department of Labor OSI1A Regulations,while performing their work.
2. Make sure that all cranes,digging apparatus,draglines.mobile equipment,and all other equipment or materials capable of contacting a
power line have attached to them any warning signs required by U.S.Department of Labor OSHA Regulations.
3 Post and maintain proper warning signs and advise all employees,new and old alike,of their obligation to keep themselves,their tools,
materials and equipment away from power lines per the following OSTIA minimum approach distances(refer to OSI IA regulations for
restrictions):
*Power Line Voltages "Personnel and Et:Moment Cranes and Derricks Travel under or near Power Lines(on construction sites.no load)
(29 CFR 1910.333 and 1926.600) (29 CFR 1926.1407,140R) (29 CFR 1926.600—Equipment)(1926.1411—Cranes and Derricks)
0-750 volts 10 Feet 10 Feet 4 Feet 4 Feet
751-50,000 volts 10 Feet 10 Feet 4 Feet 6 Feet
69,000 volts 11 Feet 15 Feet 10 Feet 10 Feet
115,000 volts 13 Feet 15 Feet 10 Feet 10 Feet
138,000 volts 13 Feet 15 Fat 10 Feet 10 Feet
230,000 volts 16 Feet 20 Feet 10 Feet 10 Feet
500,000 volts 25 Feet 25 Feet 16 Feet 16 Feet
*When uncertain of the voltage,maintain a distance of 20 feet for voltages up to 350,000 volts and SO feet for voltages greater than 350,000 volts.
"For personnel approaching Insulated secondary conductors less than 750 volts,avoid contact(Maintain 10 Feet to bare energised conductors less than 750 volts).For
qualified personnel and insulated serial lift equipment meeting requirements of 29 CFR 1910 333,distances may be reduced to those shown in 29CFR 1910.333 table S-5
4. All excavators are required to contact the Sunshine State One Call of Florida,phone number 1-800-432-4770 or 811 a minimum of two
working days(excluding weekends)in advance of commencement of excavation to ensure facilities arc located accurately.
5. Conduct all locations and excavations in accordance with the Florida Statute 556 of the Underground Facilities Damage Prevention&Safety
Act and all local city and county ordinances that may apply.
6. When an excavation is to take place within a tolerance zone,an excavator shall use increased caution to protect underground facilities.
The protection requires hand digging.pot holing,soft digging.vacuum methods,or similar procedures to identify underground facilities.
A copy of this notification must be provided by you to each contractor and subcontractor on this project, to be shared with their supervision and
employees prior to commencing work on this project.
AT1N:Sue Zimmerman.Collier County 14700 immokalec Road.Naples.FL 34120
14700 Immokalee Road.Naples.FL.34120 Address
Means by which thi tification was provided to customer and/or
co tactor Address
/ 1' ,i July Z2017
•'.A.— ��. _ Date
FPI.Repr., . "gnature 1 a \D.-1\V .
Date
Cust�rer eveloper/('ontractorRepresentative if
Approved as to � r��c1 legality r•-i T: ( qr
DWIGHT E. B CK, C1ork �y {
Assistant County •(114;.nv'y C1C i \—\W By aS Ch8f A 1C S
. b C
WR 4 5618445
* R719
FPL
SPECIFICATIONS FOR PRECAST TRANSFORMER LOCATION
WORK REQUEST: 5618445 DATE:July 7,2017
NAME`.OF CUSTOMER:Sue Zimmerman,Collier County
PROJECT:NERDC
ADDRESS: 14700 Immokalee Road,Naples,FL 34120
FPL REPRESENTATIVE:Anna Smith Bradley TELEPHONE:239-947-7374
SECONDARY DELIVERY VOLTAGE:277/480 V,three phase
CUSTOMER AGREES TO:
1.GENERAL:
1.I Provide a suitable location,compacted and level to 3"below final grade,for FPL transformer pad and install
secondary/service from pad to building as specified on the attached Exhibit"A"and as outlined below.
1.2 It is further understood and agreed that subsequent relocation or repair of the FPL system,once installed,will be paid by the
customer if said relocation or repair is a result of a change in the layout or grading by the customer or any of the customer's
contractors or subcontractors from the time the underground facilities were installed;and that subsequent repair to FPL's
system,once installed,will be paid by the customer if said repair is a result of damage caused by the customer or any of the
customer's contractors or subcontractors.
1.3 Notify general contractor,electrical contractor and appliance suppliers of the service voltage to be supplied by FPL.
2 EASEMENTS:
Provide FPL with good and sufficient recorded easements,including legal descriptions and survey work to produce such
easements,for the installation and maintenance of its electric distribution facilities must be granted or obtained,at no cost to
FPL,prior to FPL's energizing its facilities.
3. SITE REQUIREMENTS:
3.1 GRADE:within the easement,fill or cut to within 6"of final grade,provide grade stakes and clear easement of trees,
stumps,construction material,and other obstacles before and during construction by FPI.or FPL.contractors.
3.2 COMPACTION;after FPL or its contractor has backfilled the trench using rough-grading techniques,the customer is
responsible for providing compacting or other special backfill.FPL will not be responsible for settling of the trench route.
3.3 PLANS:provide FPI.with location and depth information and/or drawings of all existing or proposed underground facilities
on the customer's property.Locate or expose underground facilities when requested by FPL.
3.4 NOTIFICATION:provide FPL with at least three(3)weeks notice prior to the commencement of paving,landscaping,
sodding,sprinkler systems and other surface work.Customer will bear the cost of restoring these obstructions to their
original condition if above notice is not provided.
4. TRANSFORMER PAD LOCATION:
4.1 LOCATION:pad will be installed at grade level and located at NERDC.See Exhibit"A"for exact location of precast
concrete pads,handholes,and conduit trenches.
4.2 CLEARANCES;a minimum clearance of three(3)feet must be maintained at side and rear of transformer pad and eight(8)
feet in front of transformer pad as shown on the attached drawing DCS UN-2I.This clearance applies to all types of
obstructions including landscaping and fences.
4.3 PROTECTION:provide and install curbs and/or protective barriers,when required,as detailed on DCS UN-21,after the
installation of concrete pads and transformers.Curbs and/or barriers must be in place prior to FPL energizing the service.
1 C 5
�I'_►* WR#5618445
R719
FPL
5 CT METERING:
When metering current transformers(CT's)are required,they will be located as specified on the attached Exhibit"A"and
installed by FPL.The customer will provide and install a I-1/2 inch galvanized conduit from the meter cabinet to the
location of the CT's.Conduit run is not to exceed 10 feet in length between CI's and meter with no more that two(2)90
degree bends unless pre-approved by FPI..Conduit pull outlet boxes(LB's)are not to be used.
6. SSDR METERING:
If solid state date receiving(SSDR)metering is required,the customer will provide and install facilities for the SSDR
metering equipment as detailed on the attached"Customer Requirements for SSDR Metering Equipment"sheet.
7. CUSTOMER SERVICE ENTRANCE:
7.1 GENERAL:provide and install secondary/service to padmounted transformer from electrical equipment/meter room.
7.2 CONDUITS:the maximum cross sectional area to be occupied by the customer's service conduits is limited to the arca given
in the attached Exhibit"A".Terminate conduits in pad at three(3)inches above final grade.All conduits for future services
must be installed at this time.
7.3 CONDUCTOR:the service conductors are to be limited to a maximum of eight(8)per phase at each transformer.Provide
ten(10)feet of cable beyond conduits for connection to FPI.facilities in transformer compartment.Maximum size of
conductor is 750 MCM AL or 600MCM CU.
FPL AGREES TO:
1. Provide conduit(except under buildings),handholes,concrete pads,padmounted transformers,and primary and secondary cable.
2. Provide and install ground rods at transformer.
3. Provide electronic markers for customer's installation when required.
4. Connect customer's service cables to FPL facilities in transformer compartment.
5. Provide and install metering wiring between meter cabinet and CT's where applicable.
6. Maintain all equipment and material installed by FPL.
IMPORTANT:
This specification is based on the customer's submitted plans and any changes in these plans may result in additional costs,
which the customer agrees to pay. When required,the customer agrees to pay a contribution for the differential cost between
overhead and underground service.The agreement and requirements as outlined in this specification,Exhibit"A",and all
attachments MUST be adhered to.Any non-conformance or changes may result in delays until these specifications are met.
Any changes or variations from these specifications must be submitted to and approved by FPL in writing.
0
16C 5
WR#5618445
R719
FPL
ACCEPTANCE OF SPECIFICATIONS:
I hereby certify that I am authorized to accept these specifications on behalf of the customer and that I will deliver a copy of
these specifications to the customer and all affected contractors:
REPRESENTING THE CUSTOMER:
Andy Solis
NAME:
DATE: a I a""i NIS
Chairman
TITLE:
TELEPHONE NUMBER. ) 55• - G "/
SIGNATURE:
I hereby certify that I am authorized to accept these specifications on behalf of FPL:
REPRESENTING FPL:
NAME:Anna Smith Bradley
DATE:July 7.2017
TITLE:Associate Engineer
TELEPHONE NUMBER:239-947- 374
SIGNATURE: _
Approved as to form and legality
: : TE. t3ROOK, E;lta
Assistant County Atte ey
_gI cj. \�
Attest as to Chairman's a\�
signature only.
c(t
0
16C 5
WR 4 5618445
8719
FPL
TRANSFORMER PAD LOCATION AND SPECIFICATION
PROJECT: NERDC DATE: July 7,2017
ADDRESS: 14700 Immokalee Road Naples,FI.,34120
CUSTOMER AGREES TO:
Provide recorded casement far all FPI.facilities on Customer's property PPL will not start construction until these casements are cleared by the
customer of all conflicts preventing construction. Should paving.grass,landscaping or sprinkler systems be installed prior to construction of the
underground distribution facilities,the customer will hear the cost of restoring same to their original condition.
Provide location and depth information for all underground facilities and fill or cut to within 6 inches of final grade within the casement. (Sec
attached referenced prints.)
Notify FPI.representative two weeks in advance of paving schedule so that FPI can install ducts if required
Make arrangements for location of FM.pads es shown on location sketch. Provide and install secondary service to padmount transformer. Use a
maximum of 8 cables per leg. (See pad detail for entrance space availability for customer service cable) Terminate conduits 3 inches above final
grade and provide 7 feet of cable per leg beyond the conduit ends for connection to transformer terminals
Compact and level 3 inches below final grade an area sufficient for the concrete pad Provide clear space of 8 feet at the front and 4 feet at sides and
rear of the transformer pad to allow for a safe working area.
Keep area above transformer pad clear to allow setting transformer with a crane. If current transformers are required,provide and install 11/2 inch
rigid conduit from CTs to meter location. Maximum horizontal distance from pad to meter is NA feet.
Provide a clear space 36 inches in front of meters. If built up meter centers arc to be used,provide FM,representative with shop drawings of centers
and layout sketch of meter room for FPL approval prior to purchase
FPL AGREES TO:
Provide pad and install the padmount transformer.
Provide and install primary ducts and/or cable from FM.facilities to the padmounted transformer.
Provide and install ground rods at the transformer.
Connect customer's service cables to FPL facilities in transformer compartment
Provide meter wiring when current transformers arc required.
Provide 277/480 V,three phase service.
REPRESENTING CUSTOMER:
I hereby certify th ant au ized to accept fications on behalf of the customer and that I have delivered a copy of these specifications to
the customer an II affec contractors.
NAM DATE: a \ 411«
(signature)
Andy Solis
NAME:
(print or type)
TITLE: Chairman TELEPHONE#: . 3 9— a5 a - 8(00 a
REPRESENTING FPL:
I hereby certify that I am authorized to accept these specifications on behalf of Florida Power and light Company.
NAME:GLAAvio•-•____Spa;,k ATE:July 7,2017 �`'..\\t'
Approved as to form and legality � y an
'T E..!3 '!'Q• v1( Crxr:,. 1
�- . _ Assistant County Attt.Y \�
Attest as to Chal an ,C
16C 5
WR It 5618445
R7I9
FPL
Florida Power&Light Company
ATTN:Anna Smith Bradley
1220 5th Ave N
Naples.FL 34102
Re: Installation of Underground Electric Distribution Facilities
Project: NERDC
Florida Power&Light Company Work Request a 5618445
Dear Anna Smith Bradley:
This is to notify you that the site at the aforementioned project is ready for the installation of your underground electric distribution facilities:
1. The underground cable route has been cleared of trees stumps and all obstructions.
2. The cable route has been filled or cut to within 6"of final grade.
3 Grade stakes have been set along the cable route marked to indicate final grade.
4. Lot lines and corners have been staked as you requested for reference to locate the cable route.
5. Any grade or reference stakes found missing will he replaced by our surveyors at your request.
6. All flooded areas have been drained.
7. All underground facilities have been staked within 2 feet of their location along the cable mute.Stakes are marked with depth.
sine and type of facility.
8. The FPL transformer pads,splice boxes,and handholes have been installed at final grade,that they do not sit in drainage or swale
areas and are equal to or above road grades.
9. 2"conduit has been installed with 36"minimum cover,and 6"conduit at 42"minimum.Minimum clearances of 36"from gas
and 12"from all other utilities have been maintained. String has been pulled from end to end and labeled accordingly
10. Customer conduit(secondary)has been installed in the secondary window of the transformer pads
I I. It is agreed that FPI.Company will not be held responsible for the removal from the job site of any excavated rock that cannot he
used for backfill during the trench restoration process. It is further agreed that suitable fill will be made available at no cost to
FPL Company at the job site for trench restoration should the amount of removed rock require it
12. Landscaping is(and will)adhere to the guidelines set by UN-2I.
13. Th. : ove conditio .e aintained throughout the construction of Florida Power&Light Company's facilities.
Al(A.
Si r . .r Owner/Devel..er : {Y Z.. .43ROCl{, C':v1(