Agenda 12/09/2014 Item #16D16 12/9/2014 16.D.16.
EXECUTIVE SUMMARY
Recommendation to approve an Applicant-Installed Facilities Agreement for Underground
Conversions (WR#4188191 & #4188163) with Florida Power & Light Company (FPL) for
phase two and three of the Vanderbilt Beach Municipal Service Taxing Unit (MSTU)
Utility Conversion Project.
OBJECTIVE: To convert the overhead utilities in the MSTU to underground in phase two (2)
and three (3) of the utility conversion project.
CONSIDERATIONS: The Vanderbilt Beach Municipal Service Taxing Unit (MSTU) is
entering phase two (2) and three (3) of a four(4) phase project to convert overhead utility lines to
underground for hurricane preparedness and to promote aesthetics within the MSTU. Phase one
(1) of the project was completed in September 2013. As a prerequisite to commencing the
project, the Board of County Commissioners entered into a Right-of-Way Agreement with FPL
for the conversion of overhead power to underground within the MSTU District.
On July 8, 2014, the Board approved the Underground Facilities Conversion Agreement with a
Government Adjustment Factor Waiver (UFCA). The UFCA is required by the Florida Public
Service Commission Tariff Section 12.1 in order to receive a 25% Government Adjustment
Factor (GAF) cost reduction from FPL. Upon execution of the UFCA, phase two (2) and three
(3) of the project can move forward with conversion to underground distribution facilities.
The MSTU used lessons learned from phase one (1) of the project to improve upon its approach
for the construction of these next two phases. In Phase one (1) FPL supplied the material and
performed all construction activity to bury the electrical system. For phases two (2) and three
(3), however, the MSTU elected to utilize the County bidding process for the construction work;
with the exception of a portion of the work that FPL requires be performed by its personnel.
This approach ensures the lowest cost construction, and places the project timing and quality
control in the hands of the County (MSTU) rather than FPL.
The Applicant-Installed Facilities Agreement for Underground Conversions with FPL describes
the agreed on conditions which govern the County's construction and installation of the
remaining portion of the underground facilities and is required by the Underground Facilities
Conversion Agreement (UFCA)
FISCAL IMPACT: There is no Fiscal Impact associated with this agreement. All expenditures
of funds for this project are done under other contracts, and this agreement applies only to the
method of doing business not the cost.
LEGAL CONSIDERATIONS: This item is approved as to form and legality, and requires
majority vote for Board approval.—SRT
GROWTH MANAGEMENT IMPACT: There is no Growth Management Impact associated
with this Executive Summary.
Packet Page -1715-
12/9/2014 16.D.16.
RECOMMENDATION: Recommendation that the Board of County Commissioners approve
(1) an Applicant-Installed Facilities Agreement for Underground Conversion (WR #4188191 &
#4188163) with Florida Power & Light Company for phase two (2) and three (3) of the
Vanderbilt Beach Municipal Service Taxing Unit Utility Conversion Project and (2) authorize
the Chairman to sign all required documents after final review by the County Attorney's Office.
Prepared By: Harry Sells, Project Manager, Public Transit&Neighborhood Enhancement
Attachments: (1) Applicant-Installed Facilities Agreement for Underground Conversion; (2)
Underground Facilities Conversion Agreement; and (3) Vanderbilt Beach Conversion Phase
Map.
Packet Page -1716-
12/9/2014 16.D.16.
COLLIER COUNTY
Board of County Commissioners
Item Number: 16.16.D.16.D.16.
Item Summary: Recommendation to approve an Applicant-Installed Facilities Agreement
for Underground Conversions (WR#4188191 �) with Florida Power & Light
Company (FPL)for phase two and three of the Vanderbilt Beach Municipal Service Taxing Unit
(MSTU) Utility Conversion Project.
Meeting Date: 12/9/2014
Prepared By
Name: SellsHarry
Title: VALUE MISSING
11/20/2014 4:27:24 PM
Submitted by
Title: VALUE MISSING
Name: SellsHarry
11/20/2014 4:27:26 PM
Approved By
Name: TownsendAmanda
Title: Director-Operations Support,Public Services Division
Date: 11/20/2014 5:06:13 PM
Name: AlonsoHailey
Title: Operations Analyst,Public Services Division
Date: 11/21/2014 9:07:59 AM
Name: SotoCaroline
Title: Management/Budget Analyst, GMD Construction&Maintenance Admin
Date: 11/21/2014 9:56:08 AM
Name: ArnoldMichelle
Title: Director-Alt Transportation Modes, Alternative T
Date: 11/21/2014 11:52:58 AM
Packet Page -1717-
12/9/2014 16.D.16.
Name: TeachScott
Title: Deputy County Attorney, County Attorney
Date: 11/25/2014 3:59:33 PM
Name: Came11Steve
Title: Administrator-Public Services,Public Services Division
Date: 11/25/2014 8:55:20 PM
Name: KlatzkowJeff
Title: County Attorney,
Date: 11/26/2014 9:29:18 AM
Name: IsacksonMark
Title: Director-Corp Financial and Mngmt Svs, Office of Management&Budget
Date: 12/1/2014 8:40:54 AM
Name: KlatzkowJeff
Title: County Attorney,
Date: 12/1/2014 10:58:38 AM
Name: OchsLeo
Title: County Manager, County Managers Office
Date: 12/1/2014 1:22:09 PM
Packet Page-1718-
EXHIBIT A 12/9/2014 16.D.16.
PROJECT PHASING MAP
NOTE: This exhibit is for the purposes of Phase One Project only. Final Boundary for Phases 2, 3, and 4 may
vary due to FPL power configuration requirements after final design plans are produced.
ASS
GN P ' -71r—
liF � .
G i
e `er M` -M
A
,X?
f
I1 W ,
a
q ;!;
11 ! ° C,
t
S
)io
6 :. •—i__
ii
w' _;
�
, :‘,[_ _______
p.
O _1;
U ;
- 11 TH AVENUE- 1
,,,,, „, ,, ,,t, is
I� ,Ii ,, ,I,� , u
LEGEND: 01 , � H wl Till
0 h ♦% 1.. W
V PHASE ONE �0 v I ' r,,' 11'
rt
7 Or ....„000/�� PHASE TWO 111 i I
I.'
I PHASE THREE ; ,, I.ii`C4 AV ,, ■I m
.r
PHASE FOUR iir , '� i7 = W
�,, ' II- �i4_1--k--,-p,, 1 Q
� ��I llllll' ' ICI<
O i� ,.1I , ' " Q
J
7 it I� „I i „ f
ji
II___ d
W�� Ea Vq --
S Ill =-ga_11BI LT ACH RO
DRAWN BY: DARRYL RICHARD, MSTU PR packet Page-1719 CTM DEPARTMENT; DATE: 02-07-11
12/9/2014 16.D.16.
ls'i ORII7A POWER&LIGHT COMPANY Eighth Revised Sheet No,9.725
Cancels Seventh Revised.Sheet No.9.725
UNDERGROUND FACILITIES CONVERSION AGREEMENT—
GOVERNMENTAL ADJUSTMENT FACTOR WAIVER
This Agreement is made and entered into this 2 th day of Ju 1 y , 201 4, by and between
the BOARD OF COMMISSIONERS FOR COLLIER COUNTY ("Local Government Applicant"), a Florida municipal
corporation or county with an address of 3299 Tamiami Trail, Bast, Naples, Florida 34112 and FLORIDA POWER&
LIGHT COMPANY("FPL"),a Florida corporation with an address of P.O.Box 14000, 700 Universe Boulevard,Juno Beach,
FL 33408-0429.
WHEREAS, the Local Government Applicant has requested that FPL convert certain overhead electric distribution facilities
located within the following boundaries(the"Conversion"):
_Phase#3-Along Vanderbilt Dr.between I l 1"'Ave.&Vanderbilt Beach Rd.including Flamingo Ave.,Heron Ave.,Egret Ave.,
Conners Ave.,Seabee Ave.,Germain Ave., Seagull Ave.,Wallet Ave.,Tradewinds Ave.Lagoon Ave.,Bayside Ave.,Pine Ave.,
Oak Ave.;Phase in - 111th Ave. from Gulf Shore Drive to Vanderbilt Dr. and Vanderbilt Beach Rd.from Gulf Shore Dr.to
Vanderbilt Dr. including Commerce St., Center St.N.,--Gulf Shore Ct„ Vanderbilt Gulf Shore Dr. (collectively, the "Existing
Overhead Facilities")(WR it 4188192 &4188168)to underground facilities, including transformers, switch cabinets and other
appurtenant facilities installed above ground as set forth in Attachment A hereof(collectively,the"Underground Facilities")(see
attached drwgs.WR#4188191&4188163).
NOW THEREFORE, in consideration of the foregoing premises and the covenants and agreements set forth herein,and other
consideration the sufficiency of which is hereby acknowledged,the parties intending to be legally bound,hereby covenant and
agree as follows:
1. Governmental Adjustment Factor Waiver("GAF Waiver")Eligibility Criteria.The Local Government Applicant
• represents and warrants that it meets the following eligibility criteria for the Conversion:
a. In order for the Conversion to incorporate a sufficient amount of overhead facilities to provide electrical
continuity,the Conversion must include a minimum of approximately 3 pole line miles or approximately 200
detached dwelling units within contiguous or closely geographic areas(the"Conversion Area"). The
$v y proximate eo
Conversion may be completed in mutually agreed upon phases,with the project size minimums applying to the
aggregate project — provided that any necessary subsequent phase begins within a 1 year period from
completion of the prior phase and the minimums are met within,at most,3 phases;and
b. The Local Government Applicant must require all customers within the Conversion Area who currently have
overhead service directly from the Existing Overhead Facilities to convert their service entrances to
underground within 6 months of completion of the Underground Facilities installation or each phase thereof
and
c. The Local Government Applicant must be willing and able to execute a right of way("ROW")agreement with
FPL if the Local Government Applicant requests that facilities be placed in the ROW;and
d. For any affected laterals,the complete lateral must be converted,including all stages of any multi-stage lateral;
and
e. The Local Government Applicant must demonstrate to the reasonable satisfaction of FPL that the sum of the
GAF Waiver credit plus any federal or state funds that the Local Government Applicant is able to use to support
the Conversion does not exceed the otherwise applicable CIAC as calculated before application of the GAF
Waiver.
Special Circumstances. Conversions which do not meet the project size minimums described in section 1.a are
eligible for the GAF Waiver in the following special circumstances:
i. 100%of the Existing Overhead Facilities within the Local Government Applicant's corporate limits
are to be converted,but are less than the pole line mileage or dwelling unit minimums;or
ii. A single lateral that serves at least one Critical Infrastructure Facility as determined by the
appropriate local agency with the mutual agreement of FPL;or
iii. An island or peninsula where 100%of the Existing Overhead Facilities are to be converted;or
m.e�.oi'ig ,Par nr„ o7161
Issued by S.E.Romig,Director,Rates and Tariffs
Effective: April 6,2010 Packet Page-1720- �, i
12/9/2014 16.D.16.-
Fifth Revised Sheet No.9.726
FLORIDA POWER&LIGET COMPANY Cancels Fourth Revised Sheet No.9.726
(Continued from Sheet No.9.725)
iv. When the aggregate size of the first 3 phases of a project would satisfy the minimum size criteria but,
for mutually engineering or logistical reasons,those phases are non-contiguous;provided that
(a)the next(4th)phase must be adjacent to one or more of the first 3 phases such that the combined
contiguous area meets the minimum size criteria, and (b)this 46 phase begins within 1 year from
completion of the 3'd phase.
2, Contribution-in-Aid-of-Construction (CIAC). The Local Government Applicant shall pay FPL a CIAC as
required by FPL's Electric Tariff and Section 25-6.115 of the Florida Administrative Code with the Otherwise
Applicable CIAC amount reduced by the GAF Waiver.
i. Otherwise Applicable CIAC $_ 2,137,250
ii. GAF Waiver $_1,271,109
iii. CIAC Due $ , 86J41._ (Cust,_Darforrns ALL UG work)
In the event the actual cost of the Conversion exceeds the estimate, the Otherwise Applicable CLAC shall be
adjusted by the lesser of(a)the difference between the actual cost of the Conversion and the estimate,or(b)10%
of the Otherwise Applicable CIAC identified above. The GAF Waiver shall also be adjusted accordingly and the
Local Government Applicant shall pay FPL the resulting difference in the amount of the CIAC Due,
3. Applicant-Installed Facilities. The Local Government Applicant may, upon entering into an applicant-
installed facilities agreement satisfactory to FPL, construct and install all or a portion of the Underground
Facilities. Such work must meet FPL's construction standards and FPL will own and maintain the completed
facilities. The Local Government Applicant agrees to rectify any deficiencies, found by FPL, prior to the
connection of any customers to the Underground Facilities and the removal of the Existing Overhead Facilities.
4. Compliance with Tariff. The Local Government Applicant agrees to comply with and abide by the requirements,
terms,and conditions of FPL's Electric Tariff.
5. Timing of Conversion. Upon compliance by the Local Government Applicant with the requirements,terms,and
conditions of FPL's Electric Tariff,this Agreement and any other applicable agreements, FPL will proceed in a
timely Manner with the Conversion in accordance with the constriction drawings and specifications set forth in
Attachment A hereof.
6. Relocation. In the event that the Underground Facilities are part of,or are for the purposes of,relocation,then this
Agreement shall be an addendum to the relocation agreement between FPL and the Local Government Applicant.
In the event of any conflict between the relocation agreement and this Agreement or the Electric Tariff, this
Agreement and the Electric Tariff shall control.
7. Term. This Agreement shall remain in effect for as long as FPL or any successor or assign owns or operates the
Underground Facilities.
8. GAF Waiver Repayment lithe Local Government Applicant does not satisfy the relevant eligibility criteria,the
Local Government Applicant shall repay the GAF Waiver within 30 days of written notice from FPL of such
failure. Additionally,if at any point within 30 years of completion of the Underground Facilities installation,the
Local Government Applicant elects to have electric service within the Conversion Area supplied by a provider
other than FPL,the Local Government Applicant shall repay FPL a pro-rata share of the GAF Waiver. The pro-
rata share(which shall reflect partial years)shall be determined as follows:
GAF Waiver*[(30—years since the Underground Facilities completion date)/30] •
(Continued on Sheet No.9.727)
Issued by: S.E.Romig,Director,Rates and Tariffs
Effective: April 4,2006
Packet Page -1721-
12/9/2014 16.D.16.
FLORIDA POWER&LIGHT COMPANY
Original Sheet No.9.727
(Continued from Sheet No.9.726)
9. Termination Prior to the Conversion Completion. Failure by the Local Government Applicant to comply with
any of the requirements,terms,or conditions of this Agreement or FPL's Electric Tariff shall result in termination of
this Agreement. The Local Government Applicant may terminate this Agreement at any time prior to the start of the
Conversion and the CIAC paid by the Local Government Applicant will be refunded to the Local Government
Applicant;provided however,that the refund of the CIAC shall be offset by any costs incurred by FPL in performing
under the Agreement up to the date of termination.
10. Assignment_ The Local Government Applicant shall not assign this Agreement without the written consent of FPL.
11. Adoption and Recording. This Agreement shall be adopted by the Local Government Applicant and maintained in
the official records of the Local Government Applicant for the duration of the term of this Agreement. This
Agreement also shall be recorded in the Official Records of the County in which the Underground Facilities are
located,in the place and in the manner in which deeds are typically recorded.
12. Conflict between Terms of Franchise Agreement. In the event of e conflict between the terms of this Agreement
and any permit or franchise agreement entered into by Local Government Applicant and FPL, the terms of this
Agreement shall control.
IN WITNESS WHEREOF,FPL and the Local Government Applicant have executed this Agreement on the date first set
forth above.
BOARD OF COMMISSIOJRERS FLORIDA POWER&LIGHT COMPANY
FOR COI 1" CO y
Sligned / "� Signed
Name TOM HENNING Name e r,�
Title CHP I RMAN Titlecif�f
Signed
Name
Title
Approved as to Terms and Canditions
/
Signed - % 4 :
�e Y,. DW GHTE,BROCK,CLERK
�► Name TOM HENNING
t tt.
Title CHAIRMAN
Deputy Cierk
Approved 's o Fp and2ee al �v' Attest as to Chairman's
,
signature only..
Signed •�
Name - t
Title l '°s ea",
Issued by: S.E.Romig,Director,Rates and Tariffs
Effective: April 4,2006
Packet Page-1722-
rne
12/9/2014 16.D.16.
Overhead to Underground Conversion-Customer Cost Sheet
Project:Collier Cnty.-Vanderbilt Bch.Phs.#2 Date Estimate Provided to Customer: May 29,2014
Cost.Performs All UG Work
Underground Cost
New UG Installation(+) $2,665,418 Cost for FPL to Install new underground facilities
Equivalent OH Installation(-) ($1,384,703) Cost to Install an overhead system at current hardening standards
Existing Overhead Cost
OH Removal&Make Ready Cost (• $556,591 Cost for FPL to remove existing overhead facilities
Existing OH Value(+) $299,944 Net Book Value of existing OH facilities to be removed
Operational Cost Dill (+) $0
Salvage Value() $0 Credit for re-usable items
Subtotal` $2,137,260 Total customer contribution as specified in Tariff 12,2,3
GAF ($1,271,109)
CIAC" $886,141
Engineering Deposit(-) ($35,903) Engineering deposit previously collected
Net Due FPL" $830,238 Total customer contribution owed
Cost Breakdowns for Customer Contributions
Total LaborNehicie Material Direct Engineering,
•
Supervision,and Support
New UG Facilities(+) $2,665,418• $0 $2,009,852 $655,566
Credit for equivalent OH(-) ($1,384,703) ($857,459) ($305,840) ($221,404)
OH Removal Cost (+) ' _ $556,591 $431,634 $25,330 $99,627
Total. $1,837,306 ($425,825) $1,729,342 $533,789
Net Book Value(+) $299,944
Operational Cost Diff (+) $0
Salvage Value(-) $0
Subtotal* $2,137,250
GAF ($1,271,109L
CIAO' $866,141
Engineering Deposit(-) 5,903) Engineering deposit previously collected
•
Net Due FPL' $930,238
Major Material Breakdown
Quantity Item
127,467 Primary UG Cable(feet)
Install 14 UG Switch Cabinet(VISTA)
147 UG Transformer(each)
8 Splice box for UG feeder(each)
62,619 OH Primary Conductor(feet)
Remove 297 Poles(each)
130 OH Transformer(each)
2,613 Primary UG Cable(feet)
Packet Page-1723-
ru
12/9/2014 16.D.16.
APPLICANT-INSTALLED FACILITIES AGREEMENT FOR UNDERGROUND
CONVERSIONS (WR#4188191&4188163)
This Agreement, made and entered into this day of , 2014, by and between
BOARD OF COMMISSIONERS FOR COLLIER COUNTY (the "Applicant"), a Florida
municipal corporation or county with an address 3299 Tamiami Trail, East, Naples, Florida
34112 and FLORIDA POWER & LIGHT COMPANY ("FPL"), a Florida corporation organized
under the laws of the State of Florida, with an address of P.O. Box 14000, 700 Universe
Boulevard, Juno Beach, FL 33408-0429.
WITNESSETH:
WHEREAS, the Applicant has executed the appropriate underground facilities conversion
agreement ("Conversion Agreement") with FPL to convert certain overhead electric distribution
facilities (collectively the "Existing Overhead Facilities") to underground distribution facilities
(collectively the "Underground Facilities"), as described in the aforementioned Conversion
Agreement(hereinafter the"Conversion");
WHEREAS, the Applicant desires to perform itself, or through its Contractors, certain Work as
such term is described in Exhibit A associated with the Conversion;
WHEREAS, FPL is willing, subject to all the terms and conditions set forth below in this
Agreement, to allow the Applicant to perform the Work based on Applicant's assurance that such
Work will be in accordance with FPL's designs, instructions, standards and specifications, and
such Work will not adversely impact FPL or its electric customers;
NOW, THEREFORE, in recognition of the foregoing premises, and in consideration of the
covenants and promises set forth herein below,FPL and Applicant do hereby agree as follows:
1. Compliance with Tariff. Applicant shall comply with and abide by the requirements,
and conditions of this Agreement, the Conversion Agreement, and FPL's electric tariff(the
"Tariff').
2. Conditions for Work to be Performed. Applicant shall, at its own cost and expense,
perform or cause to be performed, all Work, as described in Exhibit A, in accordance with
the terms and conditions of this Agreement and the standards and specifications shown in
Exhibit B. The Applicant shall provide all survey and staking to ensure that all Underground
Facilities are installed as shown in the Conversion Agreement and provide As-Built prints to
FPL within two (2) weeks of installation, signed and certified by a Florida registered
surveyor along with a FPL"Redline"document.
3. Commencement of Work. Applicant shall perform the Work, or any portion of the Work,
only upon receipt of a notice to proceed containing the approved drawings, specifications and
instructions from FPL ("Notice to Proceed"). After receipt of the Notice to Proceed,
Page 1 of 7 (Rev. 10/23/06) G
Packet Page -1724-
12/9/2014 16.D.16.
Applicant shall provide written notice of intent to commence work to FPL at least five (5)
days prior to commencement of such Work. Applicant shall not perform any excavation
work without first notifying Sunshine State One Call for identification and marking of
existing underground utilities and complying with the excavation requirements set forth in
Florida Statute Chapter 556.
4. Materials. All Materials are to be supplied by FPL and shall be picked up by Applicant at
the following address at a mutually
agreed upon time, typically with 5 business days minimum notice, but no more than 15
business days notice, unless mutually agreed upon. Alternatively, FPL will, at Applicant's
expense, have the material delivered to a mutually agreed upon location. Applicant assumes
liability for any materials lost, stolen or damaged once these materials are picked up by, or
delivered to,the Applicant.
5. Contractors. Applicant may enter into a contract with a contractor for the performance of the
Work, or any portion thereof, provided that the contractor has been approved by FPL in
writing prior to execution of such contract. Applicant shall not make any substitution of any
contractor for the performance of Work unless the substitution is approved by FPL in writing.
The Applicant's contractor(s) shall perform ALL work as outlined within Exhibit A &
Exhibit B. No contract or purchase order between Applicant and its contractor(s) shall bind
or purport to bind FPL, but each contractor entering into a contract with Applicant with
respect to the Work shall name FPL as an intended third-party beneficiary and include a
provision permitting its assignment to FPL upon FPL's written request, following default by
Applicant or termination or expiration of this Agreement. Applicant shall provide FPL with
written certification from each of its contractors performing Work that all warranties,
guarantees and obligations of such contractors are equivalent or better than those granted by
such contractor to FPL for similar work and shall require that each such contractor name FPL
as an intended third party beneficiary of such warranties, guarantees and obligations with the
same rights of enforcement as Applicant. Applicant shall assign all representations,
warranties, guaranties, and obligations of all contractors at the request and direction of FPL,
and without recourse to Applicant, to FPL upon default by Applicant or teunination or
expiration of this Agreement; provided, however, that, notwithstanding such assignment,
Applicant shall be entitled to enforce each such representation, warranty, guaranty, and
obligation so long as Applicant has any liability under this Agreement. Applicant hereby
assigns to FPL, effective as of the termination or expiration of this Agreement, all
representations, warranties,guaranties and obligations of all Contractors.
6. Right of Entry. FPL reserves the right, together with its agents or designees to enter the
Jobsite as it may elect for the purpose of inspecting the Work, or constructing or installing
such collateral work as it may desire,or testing,boring or surveying, or any other purpose.
7. Inspection and Correction of Deficiencies.
bJ
Pane 2 of 7 (Rev. 10/23/06)
Packet Page -1725-
12/9/2014 16.D.16.
7.1. All Work shall be properly inspected and tested, if appropriate, by Applicant and
shall at all times be subject to additional inspection by FPL and its designee(s).
7.2. Neither the failure to make such inspection, nor the failure to discover defective
workmanship, materials, or equipment, nor approval of or payment to Applicant
for such Work shall prejudice the rights of FPL thereafter to correct or reject the
same.
7.3. Applicant shall correct any deficiencies found with the Work, including but not
limited to discrepancies that are inconsistent with FPL's design, instructions,
standards or specifications within two (2) business days. If Applicant does not
adequately rectify the identified deficiencies in the required timeframe, FPL may,at
its sole discretion, perform, or have performed by its contractor the required repairs
and Applicant shall pay FPL for any costs incurred. These requirements apply
whether the discovery of deficiencies occurs while Applicant is performing its
Work or while FPL, or its contractor,is performing its portion of the work.
7.4. If any Work or part thereof is covered over contrary to the requirements of this
Agreement or the written request of FPL, it must, if required by FPL, be uncovered
for observation and inspection and covered again at Applicant's sole expense.
7.5. If any Work that FPL has not specifically requested to observe and inspect prior to
being covered has been covered, FPL may request to see such Work or part thereof
and it shall be uncovered by Applicant. If such Work or part thereof is found to be
in accordance with this Agreement, the cost of uncovering and covering again shall
be paid by FPL. If such Work or part thereof fails to meet the requirements of this
Agreement, Applicant shall pay all costs of uncovering, correcting, and covering
again.
7.6. Applicant shall pay FPL for all time spent reviewing and inspecting Applicant's
Work.
7.7. No electric customers shall be connected to the Underground Facilities prior to all
deficiencies being rectified.
8. Indemnity/Liability of Applicant.
8.1. Subject to the provisions of Florida Statute 768.28, Applicant shall protect, defend,
indemnify and hold FPL free and unharmed from and against any liabilities
whatsoever resulting from or in connection with this Agreement, the Conversion
or in connection with the performance of the Work by the Applicant, its
employees, Contractors or Contractor employees; including but not limited to
payment disputes between contractor and Applicant. Nothing herein shall be
(6;22\
Pare 3 of 7
(Rev_ 10/23/06)
Packet Page -1726-
12/9/2014 16.D.16.
construed as a waiver of sovereign immunity as provided in Florida Statute
768.28.
8.2. Applicant shall assume full responsibility for all damages and all restoration arising
in connection with the Work.
9. Design Work. FPL shall provide all design, instruction, standards and specifications
necessary to perform the Conversion.
10. Completion of Work and Ownership. Applicant shall complete the Work by
, 2014 and notify FPL when said Work is complete. Upon FPL's
final written approval of the completion of the Work ("Acceptance"), Applicant
acknowledges that all rights, title and interest, free and clear of all liens, in and to the Work
shall vest in FPL. If requested by FPL, Applicant shall provide FPL, in a form acceptable to
FPL, an affidavit of Applicant certifying payment of all indebtedness to all Contractors and a
written release of liens from Applicant and each Contractor.
11. No Liability by FPL. FPL assumes no liability due to any damage, misunderstanding of
installation drawings or specifications, or any actions due to Applicant or its Contractor.
12. Suspension for Cause:
12.1. FPL may at its sole discretion, by Notice, temporarily suspend the Work, or any
portion thereof, under this Agreement when the performance by Applicant or its
contractor is unsatisfactory by FPL to obtain the results required by this
Agreement. If FPL invokes the right to suspend, it agrees not to unreasonably
deny the Applicant from continuing to work on other unaffected portions of the
project whenever possible.
12.2. The methods by which Applicant performs its Work are entirely the responsibility
of Applicant. FPL's right to suspend Work is intended solely to verify that the
Work being performed by Applicant and its Contractor conforms to the design,
instruction, standards and specifications and shall not obligate FPL to review the
efficiency, adequacy or safety of Applicant's or its Contractors methods or means
of operation or construction.
12.3. Any additional costs incurred by Applicant resulting from such suspension shall be
borne solely by Applicant.
12.4. If Applicant immediately corrects the unsatisfactory condition FPL shall authorize
resumption of the Work. Applicant's failure to immediately effect correction of
the unsatisfactory conditions shall be cause for termination of this Agreement.
13. Termination for Cause:
13.1. FPL may, upon Notice to Applicant, and without prejudice to any remedy
available to FPL under law, in equity or under this Agreement,terminate the whole
Noe 4 of'7 (I2ev. 10r23/06)
Packet Page -1727-
12/9/2014 16.D.16.
or any part of this Agreement for cause and take possession of the Work without
termination charge, penalty or obligation in the event Applicant fails to perform a
material obligation under this Agreement and fails to cure such material obligation
default within a reasonable period of time, but in no event more than ten (10)
business days, after Notice from FPL specifying the nature of such default (any
such termination referred to as a"Termination for Cause").
13.2. In the event of Termination for Cause by FPL, Applicant shall:
a. Unless instructed otherwise in the Notice, immediately stop all Work
hereunder;
b. Issue no further contracts except with the prior written consent of FPL;
c. Assign to FPL, to the extent requested by FPL, all rights of Applicant
under contracts outstanding;
d. Terminate,to the extent requested by FPL, outstanding contracts;
e. Fully cooperate and refrain from hindering or interfering in any manner
with any other persons or parties currently or prospectively performing
the Work; and
f. Take any other action toward termination, or toward preservation of the
Work,that FPL may direct.
13.3. Upon a Termination for Cause, all obligations of FPL hereunder shall terminate
effective immediately. Upon such Termination for Cause, FPL may either rework
or take over the terminated Work and proceed to provide such materials, supplies,
equipment and labor of both FPL and FPL contractors, as may be reasonably
necessary to complete said Work. FPL may have any partially fabricated portion
of the Work removed from Applicant's or contractor's facilities upon Notice to
Applicant. Applicant shall be liable for any increase of FPL's costs, including
rework costs, incurred by FPL as a result of FPL's termination of the contract for
cause.
13.4. In the event of Termination for Cause, FPL shall have no liability to Applicant for
costs incurred by Applicant as a result of such termination.
14. Termination Prior to Construction. Applicant may terminate this Agreement at any time
prior to the start of construction. If Applicant elects to still complete the Conversion,then the
Contribution-In-Aid-of-Construction (CIAC) amount provided in the Conversion Agreement
shall be revised accordingly. The revised Conversion Agreement must be executed and any
additional CIAC due received by FPL prior to the start of construction.
PaQe 5 of 7 (Rev. 10123/06)
Packet Page-1728-
12/9/2014 16.D.16.
15. Assignment. This Agreement is not assignable.
16. Applicant's Payments to FPL. Any monies that are owed by Applicant to FPL under this
Agreement shall be paid to FPL within thirty(30) days of FPL producing an invoice.
17. Notice. As used herein, the term "Notice" shall mean any formal written correspondence
providing notice of action, purpose, intent or the like given under the provisions of this
Agreement. Unless otherwise provided in this Agreement, Notice shall be delivered in
person, by courier or by certified mail and shall be effective when received. General
correspondence is not categorized as Notice.
J
Pw¢e 6 of 7 (Rev. 10123/06)
Packet Page -1729-
12/9/2014 16.D.16.
IN WITNESS WHEREOF, FPL and Applicant have executed this Agreement for the provision
of Applicant-Installed facilities to be effective as of the date first above written.
ATTEST For BOARD OF COMMISSIONERS FOR COLLIER COUNTY:
DWIGHT E. BROCK, CLERK
BY
By:
(signature)
Name:
(print or type)
Title:
(print or type)
Approved as to form and legality
By:
Scott It Teach,Deputy County Atto (signature)
Name:
(print or type)
Title:
(print or type)
Approved as to Terms and Conditions:
(signature/title)
Approved as to Form and Legal Sufficiency:
(signature/title)
For FLORIDA POWER& LIGHT COMPANY:
By:
(signature)
Name:
(print or type)
Title:
(print or type)
P...n'7 n£7
(Rev. 10123/06)
Packet Page -1730-
12/9/2014 16.D.16.
Exhibit A
WR#4188191 &4188163
Work to be Performed:
Applicant shall:
• Install all conduit and concrete products based on the attached
specifications and in the locations as indicated on the attached
drawings.
• Install cable,transformers and switch pads including the primary
and secondary cable terminations and connections. FPL will be
responsible for energizing the new underground circuit(s)to the
existing FPL electrical system.
Packet Page-1731-
12/9/2014 16.D.16.
Material Summary 1/110-4) 1 -ti3
WR#: 4188191
10#: D99000106059 512312014
Unit
of
Property Est Qty Act Qty Asb Qty Req Qty
162122027-PAD,CONCRETE FOUNDATION UX-122,0.0 Y 6.00 0.00 0.00 0.00
459615021 -TRANSFORMER, 1 PH PAD OF 13X23KV 50KVI Y 2.00 0.00 0.00 0.00
162246001-PAD,CONCRETE FOUNDATION UX-115 Y 3.00 0.00 0.00 0.00
162246800-PAD,CONCRETE FOUNDATION UX-114 Y 1.00 0,00 0.00 0.00
162248004-PAD,CONCRETE FOUNDATION UX-117 Y 137.00 0.00 0.00 0.00
162251005-PAD,CONCRETE,FOUNDATION,UX-108 Y 1.00 0.00 0.00 0.00
162690790-BOX,URD PAD AND CHAMBER FOR PM DF VI Y 6.00 0.00 0.00 0.00
223388001-CAP-BANK,URD,25KV,1200KVAR,FIXED/SWIT• Y 1.00 0.00 0.00 0.00
279209050-SW,VAC,PM DF SS,25KV 3PH,600A 422 VISTF Y 4.00 0.00 0.00 0.00
279211050-SW,VAC,PM DF-SS,25KV 431 VISTA,3FDRITA Y 2.00 0.00 0.00 0.00
•
459460051 -TRANSFORMER,PD,DF,3PH,13X23KV,150KVA Y 1.00 0.00 0.00 0.00 •
459605025-TRANSFORMER,1PH PAD 13X23KV 50KVA S.' Y 23.00 0.00 0.00 0.00
459607524-TRANSFORMER, 1 PH PAD 13X23KV 75KVA S: Y 67.00 0.00 0.00 0,00
459610029-TX,PD,100KVA,13 X 23 KVAC PR1,1PH,DF,SS Y 27.00 0.00 0,00 0.00
162240003-BOX,SPLICE FOR URD FEEDERS Y 5.00 0.00 0.00 0.00
010000002-Dummy Item N 42.00 0.00 0.00 0.00
010000003-*Dummy Purchase Item N 0.03 0.00 0.00 0.00
030028001 -CRANE RNT,SET H POLE N 11.00 0.00 0,00 0.00
100245001-CABLE,ALUM.,600 V,HM/HD POLY N 77.25 0.00 0.00 0.00
100253004-CABLE,ALUM 600V 4/0 3C TPLX HM/HD POLY N 24,944.54 0.00 0.00 0.00
100261007-CABLE,AL,25KV,2/C#1/0,3 PARALLELED N 7.21 0.00 0.00 0.00
100290007-CABLE,ALUM,25KV,21C#1/0 N 57,035.22 0.00 0.00 0.00
100298008-CABLE,AL,25KV,2/C 1000 KCMIL.. N 24,571.68 0.00 0.00 0.00
100302005-CABLE,ALUMINUM,1000V,2/C#6,SL UNDERGI N 4,699.89 0.00 0.00 0.00
103070211-CON,AL,CMPR,H-TAP,I2STR-650L TO 6-2STR N 40.00 0.00 0.00 0.00
103805016-CON,STUD MULTITAP,FOR TX,600V N 270.00 0.00 0.00 0.00
103805030-CPLR,MULTITAP TRANSFORMER,1",STUD,AL N 9.00 0.00 0.00 0.00
103805040-CON,ELCT,TRMNL,STUD MULTITAP,Z BAR,R N 78.00 0.00 0.00 0.00
103805045-CVR,CLR,SLIP ON,RIGHT HANDED,WITH-ivy N 78.00 0.00 0.00 0.00
103806500-CON,ELCT,TRMNL,Z STYLE,4 PORT,MULTITA N 8.00 0.00 0,00 0.00
112302005-WIRE,C SDB#18 SOL N 90.00 0.00 0.00 0.00
112308003-WIRE,TIE,#6,315'SPL,SOL,SDB,CU N 434.00 0.00 0.00 0.00
112309000-WIRE,TIE,#4,198'SPL,SOL,SDB,CU N 1,012.00 0.00 0.00 0.00
112332010-WIRE/CABLE,BARELEC,7 STRAND SD,2AWG N 36.00 0.00 0.00 0.00
112338010-WIRE/CABLE,7 STRAND 30,4/0 AWG,50'COIL N 18.00 0.00 0.00 0.00
120036106-CLMP,GRD,WIRE TO ROD,5/8" N 127.00 0.00 0.00 0.00
120064002-CLMP,HOT LINE,#8-#210C TAP#8-#I/OC N 9.00 0.00 0.00 0.00
120100500-CON,ELCT,LUG WITH SHEAR BOLTS,500-1001 N 9.00 0.00 0.00 0.00
120111001 -CON,CU,CMPR,H-TYPE,#8-4 CU TO#8-4 CU N 187.00 0.00 0.00 0.00
120112007-CON,CU,CMPR,H-TYPE,#6-4 CU TO#6-4 CU N 310.00 0.00 0.00 0.00
120115006-CON,CU,CMPR,H-TYPE,#6-4 CU TO#2-1/0 CU N 12.00 0.00 0.00 0.00
120135007-CON,CU,CMPR,C-TYPE,#6-4 TO#2 N 45.00 0.00 0.00 0.00
120169009-CON,C CMPR HYL#1 N 18.00 0.00 0,00 0.00
120174002-CON,C CMPR HYL300MCM N 18.00 0.00 0.00 0.00
120338005-CON,BNZ GRD TX TANK TO#6-#2 CU N 3.00 0.00 0,00 0.00
120868004-CON,CMPR,TERMINAL LUG,#1/0 CU N 3.00 0.00 0.00 0.00
122650006-STUD,BRZ GRD N 9.00 0.00 0.00 0.00 •
Packet Page -1732-
12/9/2014 16.D.16.
Material Summary
WR#: 4188191
10#: D99000106059 5123/2014
Unit
of
Property Est Qty Act Qty Asb Qty Req Qty
130405104-ROD,GRD,BRZ,COUPLING N 893.00 0.00 0.00 0.00
130613009-ROD,GRD.5/8",5'LG,THREADLESS,COPPER-C N 976.00 0.00 0.00 0.00
130614005-ROD,GRD,10'X518",THREADLESS,COPPER-Ct N 24.00 0.00 0.00 0.00
140515557-BOLT,MA,SS,1/2"X1-112",HEX HD W/NUT N 72.00 0.00 0.00 0.00
140519005-BOLT,MA STAINLESS STEEL 1/2"-13 X 2-1/2" N 86.00 0.00 0,00 0.00
140560005-BOLT,MACH,GALV,1/2"X1",W/NUT N 9.00 0.00 0.00 0.00
140562008-BOLT,MA,STL,1/2"X 2",W/NUT N 18.00 0.00 0.00 0.00
140562075-BOLT,MA,ZINC-COAT, 1/2"X 2" N 6.00 0.00 0.00 0.00
140592004-BLT,MA,5/8"X 14" N 6.00 0.00 0.00 0.00
141463003-CLIP,BOND,CU#4 SOL(1/4"DIA)FOR 1/4"BOLT N 282.00 0.00 0.00 0.00
142631007-NAIL,GROOVED 2-1/2 N 0.12 0.00 0.00 0.00
142703008-NUT,112",HEX,SS 13UNC AISI 304 F-594C N 86.00 0.00 0.00 0.00
142703009-SHEAR NUT,1/2",HEX,SS 13UNC N 18.00 0.00 0.00 0.00
144293001-SCR,LAG,318"DIA,3"LG,GALV N 1.00 0.00 0.00 0.00
•
145293100-WSHR,BELLEVILLE,SPRG,SS(17-7PH),1/2"BL1 N 86.00 0.00 0.00 0.00
145294010-WSHR,LCK,SPRG,304SS,1/2"BLT N 72.00 0.00 0.00 0.00
145355001-WASHER,STAINLESS STEEL 1/2 BOLT.078 N 136.00 0.00 0.00 0.00
145359006-WASHER,STEEL ROUND 3/8 BOLT N 33.00 0.00 0.00 0.00
145359073-WASHER,ROUND,ZINC-COAT,3/8"BLT N 28.00 0.00 0.00 0.00
145361001 -WASHER RD,1-3/8"X 7/64"FOR 1/2"BOLT N 18.00 0.00 0.00 0.00
145361078-WASHER,ZINC-COAT,1-3/8 X 7/64,1/2" N 6.00 0.00 0.00 0.00
145374005-WASHER,SPRING,5/8"BOLT N 12.00 0.00 0.00 0.00
145381001 -WASHER,SPRING,LOCK, 1/2"BOLT N 18.00 0.00 0.00 0.00
145381079-WASHER,SPRING,LOCK,ZINC-COAT,1/2" N 6,00 0.00 D.00 0.00
145395002-WASHER,SQ,2-114"X 3/16",WITH 13/16 HOL N 6.00 0.00 0.00 0.00
160308000-SPRT,CBL INS SINGLE SPOOL,1-1/8"-3-1/2" N 10.00 0.00 0.00 0.00
160310000-SPRT,CABLE BRKTASSI3LY,2.5"-3",STAINLES: N 72,00 0.00 0.00 0.00
161410002-BRKT,FRAMING MATL,90DANGLE,2 HOLES,L N 14.00 0.00 0.00 0.00
161450004-NUT,FRAMING MATERIAL,HEX,3/8" N 14.00 0.00 0.00 0.00
161463000-NUT,W/SPRG,SS,FOR 112"-13 BOLT UNISTRU' N 72.00 0.00 0.00 0.00
161479002-HOLT,CAP SCREW,HEX HEAD 3/8"-16 X 1-1/2" N 14.00 0.00 0.00 0.00
161486009-BOLT,CAP SCREW,HEX HEAD,1/2"-13 X 1-1/2" N 284.00 0.00 0.00 0.00
161507006-BRKT,FRAMING MATERIAL,U SUPPORT,SLOT N 9.00 0.00 0.00 0.00
161524008-WASHER,UNS LOCK 3/8 GALV N 14.00 0.00 0.00 0.00
161536006-WASHER,UNS SQ FLAT 1/2"GALV N 284.00 0.00 0.00 0.00
162100007-HH,POLY CNC,RECT,17"X 30"X 18"DEEP N 123.00 0.00 0.00 0.00
162120008-HH,POLY CNC,RECT,13"X 24"X 18"DEEP N 1.00 0.00 0.00 0.00
162122892-HANDHOLE,PRECAST CONCRETE,RECTANG N 8.00 0.00 0.00 0.00
163000001-K1T,SPL,HEAT SHRINK SEALING,1/0-1K AUCU N 18.00 0.00 0.00 0.00
163022000-CAP,INSULATED BUSHING,25KV 200A N 6.00 0.00 0.00 0.00
163066008-CON,ELCT,TRMNL,4 PORT MULTITAP,#6-#4/0/ N 345.00 0.00 0.00 0.00
163066009-CON,ELCT,TRMNL,5 PORT MULTITAP,#6-#4/0/ N 33.00 0.00 0.00 0.00
163079001-KIT,SPL,URD,1/OAWG COMP STR,AL,15/25KV N 18.00 0.00 0.00 0.00
163250002-BUSHING,ROTATABLE FEEDTHRU,25KV 200P N 3.00 0.00 0.00 0.00
163297009-INDICATOR,FAULT CURRENT,3 PH UG,800AN N 14.00 0.00 0.00 0.00
163474008-BRACKET,EXTENSION,POTHEAD MTG,GAL N 3.00 0.00 0.00 0.00
163502001-ELBOW,200 AMP,25KV,1/0,LOADBREAK N 247.00 0.00 0.00 0.00
•
Packet Page -1733-
12/9/2014 16.D.16.
Material Summary
WR#: 4188191
IO#: D99000106059 5/23/2014
Unit
of
Property Est Qty Act Qty Asb Qty Reg Qty
163510004-TERMINATOR,COLD-SHRINK, 15 OR 25KV, 1/C N 3.00 0.00 0.00 0.00
163511001-TERMINATOR,COLD SHRINK,15/25KV,1000KC N 9.00 0.00 0.00 0.00
163573006-ELBOW,200 AMP,25KV,1/0,INJECTION, N 30.00 0.00 0.00 0.00
163639101-KIT,25KV 600A DEADBREAK ELBOW N 42.00 0.00 0.00 0.00
163639104-CONN,COPPER TOP SHEAR BOLT,500-1K N 42.00 0.00 0.00 0.00
163639161-ADP,CBL,1K AL POLYAND 1K CU EPR,25 KV N 42.00 0.00 0.00 0.00
163645007-CAP,INSULATED BUSHING,I SKV/25KV 600A N 6.00 0.00 0.00 0.00
163864001-BSH,STANDOFF,LOADBREAK,25KV N 274.00 0.00 0.00 0.00
164131007-SWEEP,CONDUIT 6"PVC 22.5 DEG 12'6"RA N 64.00 0.00 0.00 0.00
164231001-BEND,CONDUIT,1"PVC 90D 6"R N 1.00 0.00 0.00 0.00
164238006-BEND,CONDUIT,2"PVC 90D 24R N 4.00 0.00 0.00 0.00
164239002-BEND,CONDUIT,2"PVC,45D 24R N 18.00 0.00 0.00 0.00
164239011 -BEND,CONDUIT,2"PVC 90D 36R N 826.00 0.00 0.00 0.00
164239452-BEND,CONDUIT,2"PVC,45D 36R N 300.00 0.00 0.00 0.00
164251002-BEND,CONDUIT,6"PVC 90D 48R N 6.00 0.00 0.00 0.00
164252009-BEND,CONDUIT,5"PVC 90D 48R N 1.00 0.00 0.00 0.00
164275009-CNDT,1"PVC,SCHEDULE 40,20'LENGTHS N 5.15 0.00 0.00 0.00
164331006-CNDT,2"RIGID PVC,SCH 40,20'LENGTHS N 77.25 0.00 0.00 0.00
164449007-COUPLING,CONDUIT,5"PVC,STRAIGHT N 1.00 0.00 0.00 0.00
164450005-COUPLING,CONDUIT,6"PVC,STRAIGHT N 16.00 0.00 0.00 0.00
164470006-CPL,CONDUIT,2"PVC,EXTRA LONG N 877.00 0.00 0.00 0.00
164660000-RSR,2"SCH 40 PVC OR HDPE U-GUARD N 60.00 0.00 0.00 0.00
164662002-RSR,U-GUARD BACKPLATE,2"SCH 40 X 10'L N 20.00 0.00 0.00 0.00
164663009-BOOT,RISERADAPTER,2",SCH 40 PVC OR HE N 20.00 0.00 0.00 0.00
164665109-RSR,U-GUARD,5"SCH 40 X 10'LG,PVC/HDPE N 16.00 0.00 0.00 0.00
164667101 -RSR,U-GUARD BACKPLATE,5"SCH 40 X 10'L N 4.00 0.00 0.00 0.00
164668108-BOOT,RISERADAPTER,5",SCH 40 PVC OR HE N 4.00 0.00 0.00 0.00
164762007-CNDT,FLEX,COILABLE,POLY,2"SDR 13.5,HDP N 76,485.74 0.00 0.00 0.00
164763208-CNDT,FLEX,COILABLE,POLY,6"SDR 11,HDPE N 7,796.07 0.00 0.00 0.00
229000150-CNTLR:CAPACITOR CONTROLLER ONE WAY N 1.00 0.00 0.00 0.00
334015005-ARRESTER,ELBOW,SURGE,15KV RTE N 51.00 0.00 0.00 0.00
334016001-ARRESTER,PARKING STAND,18 KV N 9.00 0.00 0.00 0.00
334228556-ARR,SURGE,DIST,RISER,18KV,FOR 23KV SY: N 9.00 0.00 0.00 0.00
334551004-BRACKET,LIGHTING ARRESTER N 3.00 0.00 0.00 0.00
500100006-SCR,MASONRY,1/4"X 1-3/4"LONG,HEXHEAD N 384.00 0.00 0.00 0.00
501558006-SCR,CAP 1/2"DIA,1-1/4"LG,HEX HD,HDG N 48.00 0.00 0.00 0.00
522116002-COM,CABLE PULLING,5 GAL PAIL N 98.55 0.00 0.00 0.00
522141007-CEMENT,PVC CONDUIT,PINT CAN N 0.24 0.00 0.00 0.00
522142000-WWW-ADHESIVE,CONDUITKIT,BONDUIT N 45.12 0.00 0.00 0.00
530114005-CLAMP,EMT 114 STL N 3.00 0.00 0.00 0.00
531220003-FUSE,OVERLOAD,8A,BYNT N 92.00 0.00 0.00 0.00
531223002-FUSE,OVERLOAD,15A,7620V,13.2KV,BYNT N 27.00 0.00 0.00 0.00
531334009-WWW-FUSE,PWR 80E 23KV N 24.00 0.00 0.00 0.00
532130016-TAPE,LINERLESS,SELF-FUSING,RUB,1-1/2"N N 62.10 0.00 0.00 0.00
532269006-TAPE,BLACK,V!NYL,3/4"X 60'X 7MIL N 3.60 0.00 0.00 0.00
546246011 -LOCK,BRONZE,PADMTTX&SWITCHGEAR N 121.00 0.00 0.00 0.00
548507009-DECAL,"DANGER-HV",3-1/2"X 5" N 130.00 0.00 0.00 0.00
Packet Page -1734-
12/9/2014 16.D.16.
Material Summary
WR#: 4188191
10#: D99000106059 5/23/2014
Unit
of
Property Est Qty Act Qty Asb Qty Reg Qty
548548007-DECAL,"CAUTION-OP.WYE-OP.DELTA" N 6.00 0.00 0.00 0.00
548560104-DECAL,WARNING,7'X10",ELECTRIC EQUIPMt N 15.00 0.00 0.00 0.00
548800083-IDENTIFICATION,CARRIER FOR TLM NUMBEF N 119.00 0.00 0.00 0.00
549378008-TAG,BLANK WHITE,2.5"X 2.5,UVEX W/FLAP N 220.00 0.00 0.00 0.00
549378009-TAG,SVC CABLE ID,2.5"X 2.5",UVEX W/FLAP N 668.00 0.00 0.00 0.00
549501004-MRKR,LIQUID,PERMANENT BLACK,NYLON TI N 8.88 0.00 0.00 0.00
•
•
Packet Page-1735-
12/9/2014 16.D.16.
Material Summary j/ '°,`1) --()71"1-7-
WR#: 4188163
10#: D99000106056 5123120/4
Unit
of
Property Est Qty Act Qty Asb Qty Req Qty
162122027-PAD,CONCRETE FOUNDATION UX-122.0,0 Y 9.00 0.00 0,00 0.00
459615021-TRANSFORMER,1PH PAD OF 13X23KV 50KVr Y 2.00 0.00 0.00 0.00
162246001-PAD,CONCRETE FOUNDATION UX-115 Y 6.00 0.00 0.00 0.00
162246800-PAD,CONCRETE FOUNDATION UX-114 Y 3.00 0.00 0.00 0,00
162248004-PAD,CONCRETE FOUNDATION UX-117 Y 10.00 0.00 0.00 0.00
162251005-PAD,CONCRETE,FOUNDATION,UX-108 Y 1.00 0.00 0.00 0.00
162690790-BOX,URD PAD AND CHAMBER FOR PM DF VI Y 8.00 0.00 0.00 0.00
223388001-CAP-BANK,URD,25KV,1200KVAR,FIXED/SWIT• Y 1.00 0.00 0.00 0.00
270682050-SWITCHGEAR,PAD MOUNT,25KV,200A,PME-' Y 1.00 0.00 0.00 0.00
279209050-SW,VAC,PM OF SS,25KV 3PH,600A 422 VIST1 Y 7.00 0.00 0.00 0.00
279211050-SW,VAC,PM DF-SS,25KV 431 VISTA,3FDR1TA Y 1.00 0.00 0.00 0.00
459460051-TRANSFORMER,PD,DF,3PH,13X23KV,150KVA Y 2.00 0.00 0.00 0.00
459462053-TRANSFORMER,PD,DF,3PH,13X23KV,300KVP Y 1.00 0.00 0.00 0.00
459481008-TRANSFORMER, 1PH,PAD, 13X23KV,50 KVA Y 1.00 0.00 0.00 0.00
459518106-TRANSFORMER,IPH,PD,13X23KV,100KVA,DF Y 1.00 0.00 0.00 0.00
459519005-TX,PD,167KVA,1PH,13 X 23KV,DF Y 3.00 0.00 0.00 0.00
459605025-TRANSFORMER, 1PH PAD 13X23KV 50KVA S: Y 12.00 0.00 0.00 0.00
459607524-TRANSFORMER, 1 PH PAD 13X23KV 75KVA S: Y 1.00 0.00 0.00 0.00 •
459610029-TX,PD,100KVA,13 X 23 KVAC PRI,1 PH,DF,SS Y 4.00 0.00 0.00 0.00
162240003-BOX,SPLICE FOR URD FEEDERS Y 3.00 0.00 0.00 0.00
010000002-Dummy Item N 60.00 0.00 0.00 0.00
010000003-*Dummy Purchase Item N 5.00 0.00 0.00 0.00
010000013-*Linear Dummy Purchase Item N 45.00 0.00 0.00 0.00
022199004-MISC.PURCHASE-1$ N 1,500.00 0.00 0.00 0.00
030028001-CRANE RNTSET H POLE N 11.00 0.00 0.00 0.00
100245001-CABLE,ALUM.,600 V,HM/HD POLY N 92.70 0.00 0.00 0.00
100253004-CABLE,ALUM 600V 4/0 3C TPLX HM/HD POLY N 1,657.27 0.00 0.00 0.00
100261007-CABLE,AL,25KV,2/C#1/0,3 PARALLELED N 721 0.00 0.00 0.00
100290007-CABLE,ALUM,25KV,2/C#1/0 N 26,789.27 0.00 0.00 0.00
100298008-CABLE,AL,25KV,2/C 1000 KCMIL.. N 21,818.49 0.00 0.00 0.00
102800002-CON,PARALLEL CLMP,CTR BOLT,CU-CU,#8-2/ N 1.00 0.00 0.00 0.00
103805016-CON,STUD MULTITAP,FOR TX,600V N 51.00 0.00 0,00 0.00
103805030-CPLR,MULTITAP TRANSFORMER,1",STUD,AL N 18.00 0.00 0.00 0.00
103505040-CON,ELCT,TRMNL,STUD MULTITAP,Z BAR,R N 21.00 0.00 0.00 0.00
103805045-CVR,CLR,SLIP ON,RIGHT HANDED,WITH TW N 21.00 0.00 0.00 0.00
103506500-CON,ELCT,TRMNL,Z STYLE,4 PORT,MULTITA N 24.00 0.00 0.00 0.00
112302005-WIRE,C SOB#18 SOL N 240.00 0.00 0.00 0.00
112308003-WIRE,TIE,#6,315'SPL,SOL,SDB,CU N 338.00 0.00 0.00 0.00
112309000-WIRE,TIE,#4,198'SPL,SOL,SDB,CU N 346.00 0.00 0.00 0.00
112332010-WIRE/CABLE,BARELEC,7 STRAND SD,2AWG N 36.00 0.00 0.00 0.00
112338010-WIREICABLE,7 STRAND SD,4/0 AWG,50'COIL N 24.00 0.00 0.00 0.00
120036106-CLMP,GRD,WIRE TO ROD,5/8" N 34.00 0.00 0.00 0.00
120064002-CLMP,HOT LINE,#8-#2/0C TAP#8-#1/0C N 12.00 0.00 0,00 0.00
120100500-CON,ELCT,LUG WITH SHEAR BOLTS,500-100t N 12.00 0.00 0.00 0.00
120111001-CON,CU,CMPR,H-TYPE,#8-4 CU TO#8-4 CU N 122.00 0,00 0.00 0.00
120112007-CON,CU,CMPR,H-TYPE,#6-4 CU TO#6-4 CU N 158.00 0.00 0.00 0.00
120115006-CON,CU,CMPR,H-TYPE,#6-4 CU TO#2-1/0 CU N 4.00 0,00 0.00 0.00
Packet Page -1736-
12/9/2014 16.D.16.
Material Summary
WR#: 4188163
10#: D99000106056 5/23/2014
Unit
of
Property Est Qty Act Qty Asb Qty Req Qty
120133004-CON,CU,CMPR,C-TYPE,#6-4 TO#4 N 4.00 0.00 0.00 0.00
120135007-CON,CU,CMPR,C-TYPE,#6-4 TO#2 N 63.00 0.00 0.00 0.00
120169009-CON,C CMPR HYL#1 N 48.00 0.00 0.00 0.00
120174002-CON,C CMPR HYL300MCM N 48,00 0.00 0.00 0.00
120338005-CON,BNZ GRD TX TANK TO#6-#2 CU N 4.00 0.00 0,00 0.00
120864009-CON,TRM,COMP,CU,ST,1HP,#4SOLT0,1/2" N 2.00 0.00 0.00 0.00
122650006-STUD,BRZ GRD N 12.00 0.00 0.00 0.00
130405104-ROD,GRD,BRZ,COUPLING N 290.00 0.00 0.00 0.00
130613009-ROD,GRD.5/8",51G,THREADLESS,COPPER-C N 272.00 0.00 0.00 0.00
130614005-ROD,GRD,10'X5/B",THREADLESS,COPPER-Cl N 32.00 0.00 0.00 0,00
140515557-BOLT,MA,SS,112"X1-1/2",HEX HD W/NUT N 105.00 0.00 0.00 0.00
140519005-BOLT,MA STAINLESS STEEL 1/2"-13 X 2-1/2" N 192.00 0.00 0.00 0.00
140560005-BOLT,MACH,GALV,1/2"X1",W/NUT N 12.00 0.00 0.00 0.00
140562008-BOLT,MA,STL,1/2"X 2",W/NUT N 24.00 0.00 0.00 0.00
140591008-BLT,MA,5/8"X 12" N 8.00 0.00 0.00 0.00
141463003-CLIP,BOND,CU#4 SOL(1/4"DIA)FOR 1/4"BOLT N 46.00 0.00 0.00 0.00
142631007-NAIL,GROOVED 2-1/2 N 0.16 0.00 0.00 0.00
142703008-NUT,1/2",HEX,SS 13UNC AISI 304 F-594C N 192.00 0.00 0.00 0.00
142703009-SHEAR NUT,1/2",HEX,SS 13UNC N 24.00 0.00 0.00 0.00
145293100-WSHR,BELLEVILLE,SPRG,SS(17-7PH),1/2"BL1 N 192.00 0.00 0.00 0.00
145294010-WSHR,LCK,SPRG,304SS,112"BLT N 105.00 0.00 0.00 0.00
145355001-WASHER,STAINLESS STEEL.1/2 BOLT.078 N 312.00 0.00 0.00 0.00
145359073-WASHER,ROUND,ZINC-COAT,3/8"BLT N 34.00 0.00 0.00 0.00
145361001 -WASHER RD,1-318"X 7/64"FOR 1/2"BOLT N 24.00 0.00 0.00 0.00
145381001 -WASHER,SPRING,LOCK,1/2"BOLT N 24.00 0.00 0.00 0.00
145395002-WASHER,SQ,2-114"X 3116",WITH 13116 HOL N 8.00 0.00 0.00 0.00
160308000-SPRT,CBL INS SINGLE SPOOL,1-118"-3-112" N 12.00 0.00 0.00 0.00
160310000-SPRT,CABLE BRKTASSBLY,2.5"-3",STAINLES: N 105.00 0.00 0.00 0.00
161410002-BRKT,FRAMING MATL,9ODANGLE,2 HOLES,L N 17.00 0.00 0.00 0.00
161450004-NUT,FRAMING MATERIAL,HEX,318" N 17.00 0.00 0.00 0,00
161463000-NUT,W/SPRG,SS,FOR 1/2"-13 BOLT,UNISTRU" N 105.00 0.00 0.00 0.00
161479002-BOLT,CAP SCREW,HEX HEAD 3/8"-16 X 1-1/2" N 17.00 0.00 0.00 0.00
161486009-BOLT,CAP SCREW,HEX HEAD,1/2"-13 X 1-1/2" N 44.00 0.00 0,00 0.00
161507006-BRKT,FRAMING MATERIAL,U SUPPORT,SLOT N 12.00 0.00 0.00 0.00
161524008-WASHER,UNS LOCK 3/8 GALV N 17.00 0.00 0.00 0.00
161536006-WASHER,UNS SQ FLAT 1/2"GALV N 40.00 0.00 0.00 0.00
162100007-HH,POLY CNC,RECT,17"X 30"X 18"DEEP N 2.00 0.00 0.00 0.00
162122892-HANDHOLE,PRECAST CONCRETE,RECTANG N 18.00 0.00 0.00 0.00
163000001-KIT,SPL,HEAT SHRINK SEALING,1/0-1KAUCU N 48.00 0.00 0.00 0.00
163022000-CAP,INSULATED BUSHING,25KV 200A N 9.00 0.00 0.00 0.00
163066008-CON,ELCT,TRMNL,4 PORT MULTITAP,#6-#4/0/ N 6.00 0.00 0.00 0.00
163066009-CON,ELCT,TRMNL,5 PORT MULTITAP,#6-#4/0/ N 3.00 0.00 0.00 0.00
163079001-KIT,SPL,URD,1/OAWG COMP STR,AL,15/25KV N 48.00 0.00 0.00 0.00
163250002-BUSHING,ROTATABLE FEEDTHRU,25KV 200P N 3.00 0.00 0.00 0.00
163297009-INDICATOR,FAULT CURRENT,3 PH UG,800AN N 17.00 0.00 0.00 0.00
163474008-BRACKET,EXTENSION,POTHEAD MTG,GAL' N 4.00 0.00 0.00 0.00
163502001-ELBOW,200 AMP,25KV, 1/0,LOADBREAK N 73.00 0.00 0.00 0.00
Packet Page -1737- •
12/9/2014 16.D.16.
Material Summary
WR#: 4188163
10#: D99000106056 5/23/2014
Unit
of
Property Est Qty Act Qty Asti Qty Reg Qty
163511001-TERMINATOR,COLD SHRINK,15/25KV,1000KC N 12.00 0.00 0.00 0.00
163573006-ELBOW,200 AMP,25KV,1/0,INJECTION, N 52.00 0.00 0.00 0.00
163639101-KIT,25KV 600A DEADBREAK ELBOW N 60.00 0.00 0.00 0,00
163639104-CONN,COPPER TOP SHEAR BOLT,500-1K N 60.00 0.00 0.00 0.00
163639161 -ADP,CBL,1K AL POLY AND 1K CU EPR,25 KV N 60.00 0.00 0.00 0.00
163864001-BSH,STANDOFF,LOADBREAK,25KV N 121.00 0.00 0.00 0.00
164131007-SWEEP,CONDUIT 6"PVC 22.5 DEG 12'6"RA N 76.00 0.00 0.00 0.00
164231001-BEND,CONDUIT,1"PVC 90D 6"R N 1.00 0.00 0.00 0.00
164239011-BEND,CONDUIT,2"PVC 90D 36R N 216.00 0.00 0.00 0.00
164239452-BEND,CONDUIT,2"PVC,45D 36R N 76.00 0.00 0.00 0.00
164251002-BEND,CONDUIT,6"PVC 90D 48R N 16.00 0.00 0.00 0.00
164275009-CNDT,1"PVC,SCHEDULE 40,20'LENGTHS N 5.15 0.00 0.00 0.00
164331006-CNDT,2"RIGID PVC,SCH 40,20'LENGTHS N 87.55 0.00 0.00 0.00
164450005-COUPLING,CONDUIT,6"PVC,STRAIGHT N 20.00 0.00 0.00 0.00
164470006-CPL,CONDUIT,2"PVC,EXTRA LONG N 217.00 0.00 0.00 0.00
164665109-RSR,U-GUARD,5"SCH 40 X 10'LG,PVC/HDPE N 16.00 0.00 0.00 0.00
164667101-RSR,U-GUARD BACKPLATE,5"SCH 40 X 10'L N 4.00 0.00 0.00 0.00
164668108-BOOT,RISER ADAPTER,5",SCH 40 PVC OR Ht N 4.00 0.00 0.00 0.00
164762007-CNDT,FLEX,COILABLE,POLY,2"SDR 13.5,HDP N 25,450.27 0.00 0.00 0.00
164763208-CNDT,FLEX,COILABLE,POLY,6"SDR 11,HDPE N 7260.47 0.00 0.00 0.00
229000150-CNTLR:CAPACITOR CONTROLLER ONE WAY N 1.00 0.00 0.00 0.00
334015005-ARRESTER,ELBOW,SURGE,15KV RTE N 69.00 0.00 0.00 0.00
334016001 -ARRESTER,PARKING STAND,18 KV N 9.00 0.00 0.00 0.00
334228556-ARR,SURGE,DIST,RISER,18KV,FOR 23KV SY. N 12.00 0.00 0.00 0.00
334551004-BRACKET,LIGHTING ARRESTER N 4.00 0.00 0.00 0.00
500100006-SCR,MASONRY,1/4"X 1-3/4"LONG,HEXHEAD N 72.00 0.00 0.00 0.00
501558006-SCR,CAP,1/2"DIA,1-1/4"LG,HEX HD,HDG N 68.00 0.00 0.00 0.00
501809009-SHIELD,LEAD EXPANSION FOR 1/2"SCREW N 4.00 0.00 0.00 0.00
522116002-COM,CABLE PULLING,5 GAL PAIL N 40.42 0.00 0.00 0.00
522141007-CEMENT,PVC CONDUIT,PINT CAN N 0.27 0.00 0.00 0.00
522142000-WWW-ADHESIVE,CONDUIT,KIT,BQNDUIT N 12.97 0.00 0.00 0.00
530114005-CLAMP,EMT 1/4 STL N 4.00 0.00 0.00 0,00
531220003-FUSE,OVERLOAD,8A,BYNT N 19.00 0.00 .0.00 0.00
531223002-FUSE,OVERLOAD,15A,7620V,13.2KV,BYNT N 11.00 0.00 0.00 0.00
531331000-WWW-FUSE,PWR 40E 23KV N 1.00 0.00 0.00 0.00
531334009-WWW-FUSE,PWR 80E 23KV N 45.00 0.00 0.00 0.00
531563105-WWW-FUSE,HOLDER SME-4Z 25KV 200 AMP, N 3.00 0.00 0.00 0.00
532130016-TAPE,LINERLESS,SELF-FUSING,RUB,1-1/2"to N 1.80 0.00 0.00 0.00
532269006-TAPE,BLACK,VINYL,3/4"X 60'X MIL N 9.60 0.00 0.00 0.00
546246011 -LOCK,BRONZE,PADMTTX&SWITCHGEAR N 36.00 0.00 0.00 0.00
548507009-DECAL,"DANGER-HV",3.1!2"X 5" N 44.00 0.00 0.00 0.00
548548007-DECAL,"CAUTION-OP.WYE-OP.DELTA" N 12.00 0.00 0,00 0.00
548560104-DECAL,WARNING,7"X10",ELECTRIC EQUIPMI N 21.00 0.00 0.00 0.00
548800083-IDENTIFICATION,CARRIER FOR TLM NUMBEF N 22.00 0.00 0.00 0.00
549378008-TAG,BLANK WHITE,2.5"X 2.5",UVEX W/FLAP NI 215.00 0.00 0.00 0.00
549378009-TAG,SVC CABLE ID,2.5"X 2.5",UVEX W/FLAP N 18.00 0.00 0.00 0.00
549501004-MRKR,LIQUID,PERMANENT BLACK,NYLON TI N 2.33 0.00 0.00 0.00
Packet Page -1738-
12/9/2014 16.D.16."
Exhibit B
Standards and Specifications
Packet Page -1739-
12/9/2014 16.D.16.
•
•
•
•
SPECJ] ICATICNS FOR UNDERGROUND CCNDIJIT INSTALLATION
1. Conduit,handhole, and transformerpadplacement shall be in the easement provided and in accordance with the design drawings
and'field staling.
•
2. Use only FPI:supplied conduit with FPL supplied beads. (Figure 1)
3. Glue.all'joints securely with FPL supplied glue. (Appendix A)
4. FPL conduit markers must be placed at all conduit ends. (Figure 1)
S. Primary conduit is to have a rainimuu of 36 inches of cover.Secondary conduit is to have a minimum of 24 inches of cover.
•(Figure I).Secondary conduit may be placed at 36"depth when in the same trench as primary conduit.
6. All service and street light conduit is to have 24.—30 inches of cover at property line. All future service stub-outs at transformer
locations to be installed with 90's..Where primary,secondary, or street light conduit runs tun horizontally,36 inch radius 90
• degree bends are to be used.
'7. Cap all ends of the conduit with FPL supplied end caps. Denote termination point of each conduit run on the capped end,
(Appendix B).All conduit ends are to be terminated 1—2 feet above final grade except at transformer locations where conduit
ends are.to be,terminated 3 inches above final grade. (Figure 3)
8. Install 1#12 copper locate wire supplied by FPL in each trench per attached specs(Figure 4). All ends of the##12.copper locate
wire.must be exposed above grade, and secured with a tie wrap to a piece of stubbed up conduit for future Iocates.(Figure 4)
9. Conduits terminated at transformer locations to be installed with templates supplied by FPL per Figure 3A,3B, or 3C according to
. the type of transformer being installed. (Consult your Service Planner).
•
•
Packet Page -1740-
12/9/2014 16.D.16.
10.Concrete transformer slabs provided by FPL are to be installed level on compacted fill at final grade and oriented as shown on the
FPL design drawing(s)(Figure 3)
11.Conduits terminated at future secondary handhole locations to be installed per Figure 2.If secondary handholes are being installed
at the time of conduit installation,install 45 degree bends as shown in Figure 1.
• 12.Primary splice handhole to be installed with electronic cable marker. (Figure 2A) .
13.Install a continuous length of pull string in all conduit runs.
14.Backfill,operations are to be done carefully with special attention given to utilizing clean fill,thereby assuring,the elimination of
rock and other scrap material to insure that the conduit will not be damaged or marking devices moved and proper compaction is
achieved.
TESTING AND ACCEPTANCE GUIDELINES
wallowing notification of completed installation of underground conduits by a developer/contractor FPL will:
1_ Randomly spot check the installation depth of conduits below grade at a minimum of 2 points between each primary
termination point, (transformers,splice boxes&risers)noting the measured depth on the record drawing.
2. After confirming the correct routing and integrity of a conduit run,verify that the cable markers were installed and exposed
conduit ends are plugged.
.3. •Corrfi--m that a continuous length of pull string has been installed in all conduit runs and verify that all conduits runs
terminate in the correct locations.
4. The final acceptance of the conduit installation will occur when FPL pulls the conductor and occupies the conduit.
•
•
Packet Page -1741-
12/9/2014 16.D.16.
FIGURE 1
& 0 0
\ FUTURE SERVICE NH �'
• SECONDARY SECONDARY
C--C—^--C-•0— .,1- — ..E.. — —I– _ FUTURE SERVICE c
FIJI TRANSFORUER �---C- C.-� C—C--C—�
it T-7' FUTURE PRIUARY
"PLAN VIEW• t i
•
•
L e� LOT
ATRENCH N D cI
LOT
�STAKES��'� 1;ifi TX i2-IT FORE16it ..•�CDER I
STAKES
Al
•■- 1•f_• uTS RTES
•
1. L, i _
".! "+ 5 SECONDARY 4 'n 7o
n
• •-•—» • J.� , PRiI kYJSECONNtRY
t PR/MARY CONTINUES
. 3'-B 3•-rl PRIIAARY
"`PROFILE VIEW*
EASEMENT EASEMENT •
' '•�,.. 6., PAD & CONDUIT DETAILS
•
s ��� �.b •� SINGLE PHASE Law STYLE
ava
PAOMDUNr TRNJSFORGER
r vre r.m?�q ■ z"nom'•p I SERVICE aR
'�� 11\ K+� r rro �'' S
.an® r+c "r"w' an'I .,�c1 CONCRETE TX. PAD 5" 1JA%. SECONDARY CONDUITS
Nit 21'MD an•MOWS tts nswl ALL rnxmx s OT. 2"TOPS OF ' • � .
ORE DT OF THE NMDOOL.SoM'ME M An 30. -ALL CONDUITS +DOC 3„
IWSINOuts-ct,E WON A mot--to B1ACE M.
COROV;1s AT THE END QV TEE HANOHO B".Tilts 6•' t -.Y
Al1DM$711E 09WVCiOR TO Of 11/Rb LUE OK Ty. A •• `•I LMiOH AM AOBK THE MOWN^COkiKfLrys ABOVE Y� ���(//,
-
FRONT ELEVATION OF PAD ' TPP,U,IARY CONDUrrs
PAD CONDUIT OPENING
FPL
•
Note -Transformer location to be per specific design drawing, and
may split lot lines in some cases.
Packet Page -1742-
12/9/2014 16.D.16.
24"
24"handhole •
1
_r M1L3J{w r � I
* •
Aq service M Sweetheart/gel ports• •1
'\4 1
Y fO ,VW 5-2°conduits max. I : � ...,,,„:.,-,.., -e• - .oN e.iit,.. - LI-■ 7 r..1.„ ,
' ' .p . y-' if{.f�b
i service ry i .S��"`fy�
' e u��` 4•:'y�.F!t r0.4 FINISHED PRODUCT
G••
WHEN INSTALLING 2' CONDUITS UP TO 5 MAY BE I -- """`' ';`' •' "'
PLACED IN A 24'HANDHCLE,Please Install all conduits
within 10"of one end of the handhole.This allows cables to
drape across to the other end of handhole where the
• terminations will be placed such as sweetheart connectors or 's- �' .+ 1;.
gel port connectors.When the wires are raised out of the
handhole this.will allow approximately 18°of wire above
ground level making it easier for employees to work on in
future situations. '. ° +_. i ; { ` ht
Packet Page -1743-
12/9/2014 16.D.16.
1-"15. .4 STARING INFORMATION [ }�--15.��
TRANVORuER PAD. HAHDIt4LE &„yfABKER RTAKINR
I TRANSFORMERS, PATS AND MARKERS ARE MOST OFTEN POSITIONED AT OR NEAR THE TRENCH CENTERLINE.AS A RESULT THE
STAKES ARE USUALLY DUG UP DURING TRENCHING.OFFSET'OR FACE STAKES ARE USEFUL TO THE CONSTRUCTION FORCES
TO RE-ESTABLISH THE LOCATION OF THE FACILITIES ARM TRENCHING STAKE CENTER LINE or FNNDHOLE 44 MARKERS,
THE FOLLOWING SKETCHES ARE EXAMPLES OF FACE STAKING ANO OFFSET REFERENCE STAKING.'FACE STAKING TS PREFERRED,
PARTICULARLY FOR TRANSFORMER PADS, BUT OFFSET REFERENCE STAKES MAY BE NEEDED AT TLLIES IF TREES OR OTHER
ODSTROCTIONS T'REVENT THE USE QF FACE STAKES. ADOIRCU4L STAKE s SUCH AS CORNER STAKES MAY BE USED TO SUIT
LOCAL CONDITIONS,
2. WHERE GRADE STAKES ARE REQUIRED, INSTALL AFTER TRENCH(!•LC AT PAD OR HANDHOLE.
TRANSFORMER PAL}IANONOLT: M RIMP ,& MANHOLE STARIF
1. THE FOLLOWONG TABLE GIVES THE OIM NSIONS OF THE CONCRETE TRANSFORMER PADS TO AID IN ACCURATE STAKING.
PAD TYPE W L. APPLICATION
UX-115 6'-8” 0'-O" 30 LF FLt w/SECT.
UX-116 6'-O" .5'-0- Sio &20 W/4 SECT. & Zat OF Si/SECT.
UX-Z 17 4'-O"'4'�7' AU. 10
ux-110 4'-I0°'FO-S" PADuOUNTEO AUTOTRANSFORMER
. UN-IB , 10' 5' FEEDER SPLICE DOX
LENGTH AND WIDTH OF CONCRETE PADS .
FACE STAKE— l
FACE STAKE;
I N- lx 20' 0/S
BASEMENT LINE lx PpA
10
TO' r TK pADO* O/S
OFFSET REFERENCE STAKES---
10 PAD EASEMENT ',NC
C FPI.IRENCH 5»`351,,1
• iirii� t
STAKE T PAD!ARMED 12` i0`
PROPOSED PAD STAKE MARKED
I ■ Tx PAD
10' Il�.�1
ppm
FACE STAKE `• R
TO I N FPL. TRENCH
FIGURE'3 - FRONT LOT URD CONSTRUCTION BiOURE R- FRONT LOT URD CONSTRUCTION
FACE STAKRG a OFFSET ST RD c
EASEMENT UN£
PROPOSED-PAD . ,
FPL TRENCH-.. PROPOSED EPA.
TRANSFORMER PAD"FLAGS
113
'CORNER"CORNER QR Tx PAU" sTaxEs
TRENCH,fig}:+NO FIGURE 5 -FRONT LOT URD CONSTRUCTION
FACE STAKING-
CENTER UNE OF TRENCH STAKES SHOULD BE APPROXIMATELY SD'APART EXCEPT ON CURVES, wilERE 2S'OR so'SEPARATION
SHOULD EE=MD.ON SHALL,RADIUS CURVE THERE SHALL BE A LLNIILDA OF 4 STARES(PC,PT&?ONURE)TO AMC LOTTING THE CORDER:'
DIFFERENT METHODS OP STAKING,SUCH As A STARE PER LOT.NAY GE USED IF LOCAL CONOITIONS REQUIRE THErd.
OF P L
OR & UG DISTRIBUTION SYSTRIA STANDARDS
ORCGINATORi PRE DRAW sr. RAs
• 1 9/ON/Of UPDATE RAYING(Lind AND TTxp) two JE5 ,pi
0 B/09/51 CHANGE PAGE FORD&T Ai* RAs ,IMF_ S/ /98 APPROV5O: J.J.AICRVD? NO SC
„110. ' DAME REVISION OPJG. ORAWN APPN. SUPER PORT OH/US PRODUCT
w.,. SUP RWCES
Packet Page -1744-
12/9/2014 16.D.16.
r
D-1 5.0.3 STAKING INFORMATION D-15.0.3
(EXh ISIT "Al L
POLE AND ANOHQ1 SLAKING
t, AN ANCHOR STAKE LOCATION (REPRESENTS THE LOCATION QF THE EYE DF ME ANCHOR ROD,
2. WOOD all CONCRETE POLES THAT ARE TO BE SET 6' IN RIGHT-.OF-WAY AND WOOD POLES THAT ARE TO BE SET 1' IN
PROPERTY WA,L BE POLE CENTER STAKED, POLES SHOULD ALSO 8F CENTER STAKED WHEN IT IS NOT NECESSARY TO
HAVE AN EXTRET,IELY ACCURATE POLE SETTING. Q
POLE LOCATION 1
CENTER STAKED
•
iso EXISTING POLE LINE
Li, 0 25p' 250'* ?SO' 250''±
-' o ® ® ® ® ® sc--- xT
•
• FIGURE I POLES 0-0 ARE CENTER STAKE°
,3 WHERE MORE ACCURATE POLE SETTING Is REQUIRED, SUCH AS AT THE RIGHT-OF-WAY LINE OR THREE INCHES BACK
OF THE CORL9. THE POLE WAY BE FACE STAKED. A STRING PULLED BETWEEN TWO ADJACENT STAKES.WARRED AS FOLLOWS,
DETERMINES THE SPECIFUED FAGS LOCATION, WHERE NECESSARY THESE MARKINGS NAY BE A8$REYIATEO DR SPELLED OUI.
F,F. OR FIELD PACE S.F. OR STREET FACE.
A TaIML1U1 OF THREE POINTS SHOULD BE &IARIC£D. TM) OF THESE MUST PETERIAINE ME LINE THAT THE SPECIFIED
FACE OF THE POLE WILL BE AGAINST.THE THIRD 1155 THE POLE DOWN AS TO ITS LATERAL POSITION BETWEEN THE
FIRST Two. ,
... - •sTAKEs•
/ i 'e?;C
S' FdIN'
VARIES
weft or CURD, A • D
PROPERTY LINE DIMENSION (MAY BE"0'ZERO)°R RF}sY •
f
/
•
A dl 8'ARE MARKED (AS IN `STAKE MARKINGS") TQ INDICATE WHAT FACE Or THE POLE:15 70 Be DETERMINED
BY THEIR LOCATION_A MIL WILL BE DRIVEN INTO EACH HOB, HOLES WILL At DRILLED AND MARKED ON ■
- CONCRETE. AND HAIL AND DISCS WILL BE USED ON ASPHALT TO AID IN ALIGNFAENT "C" IS MARKED .
MOW"A"TO '13, POLE LOCATIONENUTASERS ON THE slurEHAYLBE PRESENT TO AID INEIDEN IPICATION,iJNE
OH & UG DISTRIBUTION SYSTEM STANDARDS
• CantrAVR: PI4 DRAWN BY: RAs
f 0/04/0I UPDATE SFU.W iS TIT LE AND TEICO DPU JE$ &U
,U 0/09/55 CHANGE PALE FORMAT Plug Has 4A T lu'1tt8/O9/96 APPROVED: JwE_Mayor NO SSE
DATE REVISION OAI� DRAM AAFR, SLf SUPPORT t atce$ttaOVCT
Packet Page -1745-
12/9/2014 16.D.16.
•
DI-15.0.1 STAKING INFORMATION D-15.0.1
(EXFnXPIT "A")
agia
NORMALLY ON A IVC OR WIRE STAFF', ARE USER IF FIELD CONDITIONS ALLOW CLEAR SIGHT OF THE FLAGS.
NOT TO SE USED WHEN FACE STAKING. FLAGS SHALL SE A MINIMUM OP +c x 5" WLTi-1 A 21" WIRE.
PI AS:iaAITK O
DIE APPROFINATE PRE 2N ED TYPE RAY RE USED IF SEW CORDITIQNS PLLO'6. SAS STMT.BE PINE LWITtS DN Y41-D(E FUO AND RENEWED AS FOLT9ws:
PROPOSED FPL POLE, PROPOSED FPL ANCHOR, PROPOSED FPL TRANsYOR(ER FAD, PROPOSED t,FN.TRENCH,
PROPOSED FPL ELECTRONIC CABLE MARKER, PROPOSED FPL HAND HOLE Q
STAKEBt
STAKES NORMALLY.ARE 24"TO 4$" ONE BY TWO'S DEPENDING ON LOCAL PRACUCES AND AVAILABILf1Y. B"TNJD BY TWOS,CALLED
HUBS",ARE USED WHERE EXTRA STABILITY IS NEEDED, SUCH AS COW PASYURES, UNPAVED DRNANG AREAS. ETC.AND ARE
USUALLY DRIVEN FLUSH W1YH THE GROUND.
$TAKEJIARKIII05
DEPENDING ON SURFACE CONDITIONS AT THE WORK LOCATION,DIFFERENT LIETHOOS OF STAKING MAY BE USED IN FIRTH, STAKES
OR HUBS will 9E USED. NAILS, DISCS AND PAINT WILL BE USED IN PAVEMENT OF'ASPHALTIC COMPOSITION,AND CONCRETE WILL.
BE ALL HAVE NAILS DRIVEN INTO THEM. NAPS AO ND p SCS WILL SHE USED ON ASPHALT. AND ONCRETE WILL DE LIRl EO STAKING,
PAINTED TO INDICATE THOSE POINTS,
REOARDLESS OF THE LOCATION'S CONDI1ON, OR OF THE IjEI1IOD OF STARING USED, CERTAIN MARKINDS MAY BE USED SY THE
SURVEY CREW TO INDICATE TO THE APPROPRIATE WORKING CREW WHAT EACH STAKED LOCATION REPRE$ENTSI,THE FOLLOWING IS
A LIST OF THE MOST OOMIAONLY USED 1JARKINGS. ON SHE STAKES. THESE MARKING WILL BE ON THE.2 SIDES. ON PAVED
SURFACES, THESE iUARKINCS WILL BE PAINTED.
I_ ANC' — INDICATES LOCATION OF THE EYE OF'THE ANCHOR ROD.
•
2. C" - INDICATES LOCATION OF THE EYE OF THE ANCHOR ROD_
"FpL"— INDICATES MARKINGS ON PAVEMENT (IF EXISTING) PERFEND1CU1A1i AND IN CLOSE PROXIMITY TO THE POLE LOCATION.
4. POLE CENTER STAKING SYMBOLS — APA ONE OF THE FOLLOWING DETERMINES LOCATION OF THE CENTER OF THE POLE.
A.) "CTR. POLE" OR `TOLE"MARKED ON A STAKE.
B.) "Q"OR O"WITH "POLE" IN THE CENTER, ON PAVED SURFACES OR SIOEWALK. (A NAIL do DISK MDII R88ON
MARKED "POLE' MAY ALSO BE USED.)
S. "Ck TRENCH" OR"i1 FPL TRENCH" — INDICATES CENTER LINE ALONG WHICH A TRENCH I-TO RE DUG.
S. IX Ll"DIE "CTR TIC PAD` .. INDICATES THE LOCATION OF THE CENVeR OF A TRANSFORMER PAD.
7. '10' 0/S ' TK PAD" & "20' 0/5 i TX PAD" - OFFSET REFERENCE STAKE 10' & 20'FROM THE CENTER OF
TRANSFORMER PAD, ALONG ITS EENTER LINE PERPENOTCW.AR TO TRENCH,
8_ "GTR HANDHOLE" — LOCATION qF CENTER OF HANOI1OLE.
5. "10` 0/5 CE H.ANDHOL E' & "20' DJS HANDHOLE" OFY'$ET REFERENCE STAKE :Cr& 20' FROM THE CENTER OF T-HE
THE HANDHOLE ALONG HE CENTERLINE PERPENDICULAR 70 TRENCH.
ID. "GTR MARKB2' - LOCATION OF THE CENTER THE MARKER.
11. *To'O/S MARKER" &"20' 0/S IE MARKER"
— OFFSET REFERENCE STAKE TD"& 20' FROM CENTER OF I.JARIIER PERPENDICULAR TO TRENCH.
12. " ` — GRADE AT DOTER OF PIED OR HANDHOLE.A NOTATION INDICATING NUMERLCALLY HOW MUCH 70
CUT OR FILL MAY OE PRESENT WHERE NECESSARY.
13. " " — OFFSET REFERENCE FAINT MARK ON PAVEMENT IF EXISTNG) PERPENDICULAR AND IN CLOSE PROXIMITY TO
THE HAND HOLE. CAN BE USED FOR OFFSET PURPOSES.
•
14. 412" OFFSET' REFERENCE PAINT MARK ON PAVEMENT OF EXISTING} PERPENDICULAR AND IN CLOSE PROXIMITY TO
THE LIA.RXER, CAN SE USED FOR OFFSET PURPOSES.
P L
U & UM DISTRIBUTION SYSTEM STANDARDS
OASCIHATO$: mrc mutt RAs
4/OS/CE UPDATED ORAWiMII (TITLE dt TEXT) DPIJ JES .AIM
0/09/95 cnii eE PALE FOc= PMG FiA3 jau TITLE:: Ei09/96 AAPROVEO: J.J.UCO10Y NO SCALE
mot • , RULSTD�i OfiG, t7F?Ait7u APPR.. SU SVIN CCR SHR/VICES OtwCT
Packet Page -1746-
12/9/2014 16.D.16.
-FIGS 2
•
TYPICAL SERVICE HAND ROLE XN$TALLATJON
CAPS-®- -
. A ,
FINAL GRADE
s j ECM M&S#590.61510-4
1 FM leifie<TA PER TO. PV c
Hrr
e, ......._ ALL CONDUITS
INSTALLED ON
ONE END WWI
•
.....�.■ _ ■,.•11,.1
•
2"-90 DEG(24"R-'TYPE)BEND M&S#164-23800.6
FIGURE 2A
48" PRIMARY SPLICE HAND HOLE
M&S#161-1210X3-4
FINAL GRADE ;y
EC
// S#59m61Q-4 .
r1'L uNG EYE MUST / PULLI CI PPULLINCI
BE INSIDE TL E f frf
•
2"45 DEG(IV R)BEND - - ---
I+Q I64-23945-2
•
•
Packet Page -1747-
12/9/2014 16.D.16.
FIG-URE 3 PAD & coNDurr DETAILS
SINGLE PHASE LO*STYLE
PADMOUNT TRANSFORMER
*174
e•
•
CONCRETE TRANSFORMER PAD
MG:S#162-U800-4
29:
T oro MAX
•
ft4a"atz.,""" 3"
I .1 •
S SEnVICE OR
SECONDARY
P=PRIMARY
FAD CONDUIT OPENING
3" 'al TOP OF
ALL CONDUITS
FINAL cRADE 6rJECi •
FRONT ELEVATION OF PAD
•
•
Packet Page-1748-
12/9/2014 16.D.16.
FIGURE 3A
ONE LOW STYLE & ONE REGULAR STYLE TRANSFORMER
80" ►►} .
.--i----
SINGLE PHASE SINGLE PHASE
LOW STYLE REGULAR STYLE
POWER TX LIGHTING TX
• 60"
SECOND RY CABLE TO LIGHTING TX CUSTOMER CONDUIT AREA
F C •28 112"PRIMARY 28 112" �i
PRIMARY 18.5" O 10"
PRIMARY SECONDARY
SECONDARY J,
6„
00 �,M� �
7'DA ''S.'MAX 7"
CL 112" it . . ,
(FRONT OF PAD)
•
•
Packet Page -1749-
12/9/2014 16.D.16.
FIGURE 3B
. SINGLE PHASE LOW STYLE TRANSFORMER
k • 48" • H
SECONDARY PR[MARY
���, CONDUITS • CONDUITS
I.
If-- 29" .
0000 L
13"
+ 9112"
3"MAX '�"8 {
•
• (FRONT OF PAD)
•
FIGURE 3
TWO LOW STYLE TRANSFORMERS
80" )►{
T. SINGLE PHASE SINGLE PHASE
LOW STYLE LOW STYLE
POWER TX LIGHTING TX
60"
FPL SECONDARY CABLE TO LIGHTING TX SEC/CUST.CONDUITS
•
Fd 28 i!2 ----�I 281(2" �i
PRIMARY 'O 88,8F-4
13" SECONDARY SECONDARY PRIMARY-
o^Mnx • 00
•
rYA�„ +8"-.1 4-8'144 t'''MAX 7,
rL 9..
(FRONT OF PAD)
Packet Page -1750-
12/9/2014 16.D.16.
FIGURE 4
1 -#12c INSTALLATION •
When installing conduit only(cable to be Milled later),a single #12 copper
insulated wire is to be direct buried in every trench at the same depth as the
conduits. The end of the wire are to be terminated above ground at the conduit
ends as mown. This wire waif avow empty plastic conduits to be located with
electronic equipment.
This method is not intended for cases where conduit is installed strictly for
road crossings only. In these cases ECM markers should be used to mark the
conduit ends.
c.p_s_ 1 .012c
NYLON-11E I- ,Nsuurfl WtAF
40121 M?,S I1S-ossm'+-a
GRADE .� I
PVC CONO:AT
WHERE TO INSTALL 112C WIRE
FLIT PR!(YES) RJT HH Fur SEC(NO) FUT SVC(YESJ
`rA{
}
II �l:AST 1 9 1-FUI SEC;
FUT
=M! TO HEAT TX
FLIT SEC(Y=S) ECM
Dill E2FUTSVC(NO) ECM
Packet Page-1751-
•
12/9/2014 16.D.16.
•
DRAWING SYMBOLS
CUSTOMER INSTALLED
40 CAP
. MAX.
A\ .4 PAD MOUNTED
SWITCH
—FPL INSTALLED
ffsz.
FPL POLE
I 3" •
• GRADE:
N■Av v imirimmiummem ow"
CUSTOMER INSTALLED
2" PVC RENO so',
36" RADIUS
mom.
CUIuMER NSIP I FO FPL INSTALLED
2" PVC BEND 45% 36" r COnDUIT
RAOWS GAP END.
TYPICAL PVC coNouiT BEND TYPICAL CONDUIT ENTRAtICES
AT RISER POLE INSTALLATION TO PAD MOUNTED SWITCH
$Y14,90L5
•k I ••• EXISTING PRO.PQs.ED
FPL OWNED, IN coNDult, WITH CONDUCTOR SIZE, METAL. FRC-- -- ---PN:---I-
RATE} VOLTAGE INSJLATIOt4 AND NEUTRAL INDICATED.
coNDUcTqgs - sEcoDARy - sTpall_upleg
FPL OWNED. IN CONDOR,. MTH CONDUCTOR SIZE. METAL 1/04 4/(14
1
AND NSULAT1 0 N INDICATED (HM/H3 IRK SHOW.). 11 —1-14- 7.1
liTaLcIE_ILIEJIAL$
THREE-WIRE SECONDARY SER1XE, FL OWNED IN CONDUIT 3-2C RN 1/OA TPX
WITH CONDUCTOR SZE, METAL. INSULATION A\D jACKET II
IKDICATECI.
EMPTY CCINDUIT C---
PAD M nuNTED TRANSFORVERS
PADNIDuNTED TRANTsFoRtiER. WITH kVA RATING ;11;11 13 $ 0 15
OR TERMINA1. CHAMBER, IS SMALL RECTANGLE
AT RICHT END OF SYMBOL. PRIMARY PRASE IND.CATED)
M.MEPORMER sreLE SHOWN AS FOLLOWS: (RS) - pEcLK,Ap
SIZE - 42" 4 TI:c3H, (DF) - DEAD FROM. - 32 "
HIGH. (1.2) - LOW STY.E. - 24" ÷ HIGH.
alIVELBIRL$
ri.ECTRONIG CABLE VARIKETT AND OR SPLICE PIT (BURIED)
SEIZVCE H.ANDHO LE C!)'
• .F p
1_I
Packet Page -1752-
12/9/2014 16.D.16.
APPENDIX A
RECOMMENDED PRACTICES FOR FIELD JOINING 27.0.0
OF PVC CONDUIT (USING reLL'Ali SOLVENT
CEMENT) AND PVC CONDUIT INSTALLATION
1. EXAMINE EACH LENGTH OF CONOUIT Atio ENSURE THERE ARE ND INTERICR u EXTERIOR IMPERFECTIONS,
CRAcY.S. ETC. Ri.M.OmE ALL FOREIGN MATERIAL FROM INSIDE CONDUTT.
2. usiNa A ttAcm:.Avr. FINE TOOTH WOW) SAW, OR NYLON STRING. CUT PIPE SQUARE OF REQUIRED).
RE.MovE ANY FRIRRz AND BEvEL ANY SHARP E.DGES. WIPE DRY WITH A ctRAN, URY CLOTN.
3. APPLY CEIWNT (M k S f522-1410D-7) UNIFORMLY ON INSIDE or BELL OR FITTING. APPLY LINIFORI1 COAT
OF crmrNr (Iwo CONDUIT END. D NOT POUR, SELASH, OR GLOB cEME-IFT ONI
4. 0,41,IEDIA1ELY INULIC THE CON[xirT INTO THE DE11. END OF FITTING ALL THE WAY TO THE INSIDE
---1FOULDER. ENSURE SNUG FTT AND TURN coNouir 3/4 TlIaN TO DISTRIBUTE_ t:TMENT EVENLY.
HOLD JOINT FOR AMOXIMATELY ONE MINUTE 70 ALLOW CEMEN1 TO LIC(;IN SF I TRIO. WIPE OFF
EXCESS CEMENT,
(VOTL: MANUFACTURER RECOMMENDATIONS Art 70 ALLOW FOR A MINIMUM OF 10 MINUTES
OF DRYING TIME PRIOR TO ANY BACKFILLINO. WI4iLII cONDFIoNS MAY VARY TICS SETTING TImE.)
1. EIELII_IINZALUTICeJ
LAY csos,4)..111 SN ROO TRENFL 03 NOT IOCK. IROY',' OR SLAM IT NI
7. •SUREOUN:Itlti FLENCII ilACKFILL M.'S' DE I RLL Of RUE OR SHARP R04 , CINDERS OR OTHER DEDRIS
WHICH WILL -2AMAGE CONDLIIIS DURING DACKFILL OPERATION OR SUDSEOUENI COMPACTION.
3. IN CORAL ROCK AREA'S, IT IS RECOMMENDED THAT Imo BASKFILLING =OR THE FID:4 3 10 & 7Nof1,75.
PE:R:3Ftuit).
4. INS-ALL P 'JC U UNE FIELLS ON ALL VACANT DL:TS, AS REQUIRED,
b. THE FINIS'HE'D CONDUIT q.UN SHALL BE FiDDDLI) IN AN AltFIZCIVED MA4NFR (I.E. WINCIt L/NF., MANDREL, ETC.)
TO ./ERITY CONTINUITY AND CLEANLINESS. (,4,Q,U: NU CONODIT 11',1N SHALL BE ACCLPIED AS
PROPERLY INSTALLED Lorit_rzs rP.r.E PASSAGE IS OBTAINED AND V,ERIFIED BY YPL SurrRvisioN.)
FPL
OE & ITC DISTRIBUTION SYSThM STANDARDS
asmor F;
wu 9-30--9 4 AFFROVE): 1t4 .J! ' Ho s:::ALE
suroqmcw4.
) LATE I Th LIN — 7RIL". DRisiVN;AS`f* SUPPORT STWIlt U
Packet Page -1753-
12/9/2014 16.0.16.
. ,
APPENDIX B
UV— 1 2.0.0 IDENTIFICATION OF UNDERGROUND
UV—1 2.0 0
CABLES AND VA CANT CONDUITS
GENERAL AI.1 UNDIBGROU11/ CIRCLATS SHOULD BE IUENTIFIED WHERE APPLI>BLE A.' TOLLOWS:-
I U DER NUMBER .
SVfliCli NUMBER
PHkiE.
CONDUCTOR SIZE, METAL. TYPE INSULADON AND VOLTALI RATE (IF NOT SAW AS OPERAINC, VOLlAc,E)
SOURCE OR DIRECTION OF EEC°
owNi30_1111.13
AUCCESS OF BUILDING SE-AVED
MA NumIglit
HATE of FAfilittE 011 SECTION OF CABLE (DIRECT DURILD ONLY)
' A?if 11NUSuAL CONDITIONS, I.E. cADLE ,IN cONDuiT, PARTIALLY IN CaNDufT, DIRECT MAUD, nu,
ALL c114:0S AND VAZANT coNours sHo,./..D i3E APPROPRIATELY DENTIFIED AT CACI4 TERMINAL OR SWITCONG
POlNi AND ALL INTErahrEDAATE LocATioNS sucH AS vAuLls, mAKHOLLS., PAO MOUNT'0 hltANSIORIAFIRS, DU
IIANDNo_LS. WHU4 THE CiRCLIIT OR WC ANT CONDUIT IS OWNED BY (YD4FR IRAN FLORIIIA rowt.ri & 1JE;1 ET
COWAN Y. s•ow "CUSF" ON APPROPRIATE 7&c. 1F NEcis,..;ARy ProPwATI0N CANNOT SE SHOWN ON 014E TAG,
1.,:if: AOOMONAL 1A7s,
IP4FONA4710•■ MI BE PLACED PA AppRoVen TAGS SHOWN a[1 0',V IN THE PANNIN LK:A:BIDED 1011 TIIr, FARM:ULM?
COND1103, , --
W' H31,ES 0 '1
o- ■
----(■/:.:"0.--- i I 1/ " POI ES-, .0104{{
USE INDEIffIll
WHITE..
0 0 2.•
-,.. LiARKING 1 EN
, 2'
ONLY
'------ PLAETIC TAG
ROUND ° . . DAkS e.,-Isi-Placa-81 501403-41
i----,1 ... „..
146:S ps4D-3433o-i USE MARIONE; ITN
3"
Este,5 O- (7:tig)-4} —--
AU-N414" lAGS 11---- -EkTIC;U:
(USE S/EEt. S7E1(1-) 1.44!s f 549-3413.1-7
t-d.3101.E OWNERsfir TAGS
MACE, 1N.;IDE i/E11.1.! C . L/7E DE W1-1.k TO ATTACH TAG TO c-INDUCTOCS, lieu ADF,9LSS USCG wARK1NG PEN (1&S 1545-53100-4)
I c n 1 1 1/4" I ial 1.-Ni 1
0 o I ..
r.. FPI. CWNEO I Et''.310K-Tt
OWNED
PLASM; If..; 7" I
I
37
I S DD
i ADDRESS 1 ADDRESS 1
S.
UNDERGROUND DUCT & MAN:10[1 SYSTLMS
USE Al_OMINIOM TAGS, AFFIXED TO CABLES V.411-i !,Irl 2C-1SY ON Alt CIRCUITS IN UNDFRCRCUND SY:7,-TF_ThE, SUCH AS SUBWAY VAULTS'• MAN-
Housn, I.1.1;34 KILLS, LIG, ROU1D ALL54:NIFM TAGS ARE FOR FEEDER NUIABLP AND 'N14.7..E 1U4101r1RON, Ri-C7ANGUL4R OLUIANUI:. TAGS
ARE ',ISM 120R ALL OTHT-R IDENTIriCATIDN PURPOSES ruri LxAvp:t ON Iso;ATED UEM'RAL CONDUMRS Cr PILL cA.BLL.s, ET,:.-..
DIRECT UWED AND CABLE IN CONDUIT SYSTEMS
USE ALLITANULI TAGS FOR CUSTOMER ED, AS INDICATED ARNE FOR I°LAI IONS THAT w11.1 u1 SIJUJECTIO TO SNIICHT. USE PLASTIC TA..7.5
EOR LIIID CARE TERMINATION 1 AGSING AID AT OTHER' LOCATIONS SUEII AS FkIMUUNIED IRANSFORMaZS AND ht,VDBOLES. Al IN 10
ELoot.os ma.iTm'ili DRR'A timt TO PREVENT Si:CARING. 14\51'D PLA7.TIC Thc; TO 04I31 l'. WWI r1.-RAP (letS #534-250;}:)-1).
2..-/i.ti,felE cg" 1.1, r,ING SICONDARY CABLES
11 TO ; 3020 ICI K.11 U RE. sy
,, 51 LT.] (STRFET ADORES:0 !
ST. L:, TO N.84W •Y,P)- -, -1 \ CM i
-, LptiTs
51
,,,,:, cr. _ 1., 1..:A1J \
[T2
- It,
,,
1 *1___ EZ:1171r10:./OI-- ADDRESS NUIAER
1 I ,,r_.. -.1 .1;.-
1 0 Ili ON EAC--1 IV INSIDE IX.
7 ',!1 1::ZA ic: ST WEST 1 LWZST 1
It.,_-_--...,=.......---
1370 H0(:SE ADD:IESS IiUM[3ER
3 MITE I.ILII IC-A? COMECTORS
•,...., J.,_ ,:.:7-V-7:7 ,-3 J....iN'.1■IFIN ,. ./
TO I TV,L.1
1,A1,110K tie Fii '.r.9.14.7.:1 632,LI/J.:j ..i.:"IST:
, .._=...._--_____,____
1" !: U }, I
L TOr 2,11
I L--: ' . W.771% .
TIM 1:AS11 0'..1 4-1.GLE ES 1W-12,3,G LAST RE'VISED Di. .3-15-91
'ARJ■T LE _„_....
10 IL,-1
.'?-•SI.,„ 4 STREET ADDRIZS
P , NUMBCR ON EACH F
A-PA-LE' P L
SE:WI CE
OH & UG DISTRIBUTION SYSTEM STANDARDS
ottionimm no r.,F.A.kw E-f: 14,1
C4.94GET, PA3E FOROT AND
.53-54 ?Pefil'Sr): f',..L SAIE.C.N. NO :,.."...Z
0 5-.33-s4.fir%Ism rryir.s MO Di MLNSIONr; , WO a:: rzn .V.PERvIsaFt, Duz-r-
PO. LATE RCOSttni 4.1K.C, umeet 15i( SUPPORT SE-W.5
__....
Packet Page-1754-
_
• i . **** NOTICE**** 12/9/2014 16.D.16.
....
- CALL SUNSHINE 1-800-432-4770 48HOURS BEFORE YOU DIG FOR UNDERGROUND LOCATIONS.;
I ,
- NOTIFY FPL REP. FOR INSPECTION OF TRENCH DEPTH & PVC INSTALLATION PRIOR TO
1
I BACKFILLING TRENCH.
POLE— Th
(CONC. /VMOOD)/ MAK . FPL CONCRETE-------
A 3'
+ se' FINAL GRADE TRANSFORMER PAD 4 ------. -
so
, r
36" MIN. COVER 900 BEND--\\A
Mk' •
FROM FINAL 36"RADIUS 4`
•-■;;:_,--.-- -
$"MIN. GRADE TO TOP (,,--- FPL 5" PVC
OF
CONDUIT
T
CONDUIT
fl L-------"
..
IF REQUIRED:
I BENDS AT RISER POLE TO BE ,"
ENCASED IN CONCRETE WITH f
---- - .
/ 12' MIN, SEPARATION
4-80LB. BAGS OF SAKRETE. !,,4,7
FROM FPL CONDUIT TO
FORM CONCRE1 E ADJACENT FOREIGN UTILITY WITH
10 POLE AND AT SURFACE. WELL TAMPED EARTH
GRADE---_-44,
• w./7/./Ay,X,'/./.:,<+7, ,'.!,
USE -.BL_NI) SE
GMENTTO 20
FOREIGN UTILITY— ff, - I
7 PASS UNDER ELECI RONIC 1.7.X.
OR OBSTRUCT ION
i OBSTRUCTION IF
RUQUIRED MARKER----,k 1
T
1--S.;-:-..-•.)'-- 1
L___ -----,-,,-
-------u, _ i t i --1,1------i AS REQUIRFD
I —
...._.
12" MIN SEPARATION OF WELL TAMPED EARTH
.1 —END PLUG
FPL CONDUIT CROSSING UNDERA_FOREIGN UTILrTY
NOTES: DUCT END MARKING
• BACK I-11 L WITHIN 4"OF THE CONDUIT 10 BE FREH (IF REQUIRED)
OF MATERIAL THAT MAY DAMAGE CONDUIT
SYSTEM (BOARDS, ROOKS LARGER TI IAN 1"IN
DIAME I ER, DEBRIS, El C.)
• IF COMPACTON OF I RENCH ROUTE IS REQUIRED
FOR PAVING, ETC. BEGIN MACHINE COMPACTION I
:-!".:///'2Y, -%-..%;
6" MINIMUM An:NE CONDUIT
• VVIIERE 36' OF COVER CANNOT BE MAINTAINED i, I \•
30"OF C.:0'1ER WILL BE ALLOWED WTI H `3" oF E I 1 -2'MINIMUM
.--= -.= i –1-10R1ZONTAL
CONCPr.lE ENCASEMENT AROUND THE GONDUI ,rE:T 8 ,..:.,-;;I'_-: SEPARATION
(N.E S.C. RJLE, OR PRIMARY VOLTAGES)
,-
• INSTALL A CONTI1',ILJOUS LEN 31-F I OF PM I SIRING r I r DR
IN ALL CONDUIT RUNS. FPL in : Fa_ \..,FOREIGN
...ed"''' UTILITY
• MATERIAL LIST_ 5" PVC SCI-I 40 CONDUIT CODUIT—--7
20' LENGTH (BELLED LND) 164- 3800-1 INSTALLATION OF FPL CONDUIT
PC° BEND :35" RADA1:-; 164-25250-5 PARALLEL WITH -OR -IN A SHARED TRENCH
90' BEND 98" RADUS 164-25200-9 WITH A FOREIGN UTILITY.
45° BEND 48" RADIUS 164-61400-8
5) BEND SEGMENT 164-56100-1
5"SWEEP 121-C" RADIUS 169-13000-1 ,
ZAIGHT COUPLING 164-44900-7
REPAIR SLEEVE 6' LONG 164-47530-0 I I FPI_ SUPPLIED 5" PVC_CONDUIT r
i
END PLUG 164-53500-1 I TYPICAL CUSTOMER INSTALLATION DETAILS
I, E ECTRONIC 59C-6160 -5
(DORTICNS OF UN-6, UN-15,CONC g PAD DETAILS)
Packet Page -1755-
i----- **** NOTICE**** 12/9/2014 16.D.16.
1
- CALL SUNSHINE 1-800-432-4770 48HOURS BEFORE YOU DIG FOR UNDERGROUND LOCATIONS.1
- NOTIFY FPL REP. FOR INSPECTION OF TRENCH DEPTH & PVC INSTALLATION PRIOR TO
BACKFILLING TRENCH.
POLE
(CONC./WOOD)7
FR.CONCRETE--
• 3.MAX_
+ -'-- FINAL GRADE , TRANSFORMER PAD -.F.■ _ ,
.. ----
7 /p-/ Pr ,./ ,,/,/ /,// /- „,/, 47, /70771
-,:,- //:,-, ,./ , ,,./ /7., ./././..///// // .4
, ::';'',N:-. • • 36" MIN, COVER 2-45°BENDS
FROM FINAL 36" RADIUS s')Ik
AtZ;t: 36''MIN- GRADE TO TOP
FPL 2" PVC .
OF CONDUIT r
I
CONDUIT
r,--------11-1-
IF REQUIRED:
)
BENDS AT RISER POLE TO BE--)
I 12' MIN. SEPARATION
ENCASED IN CONCRETE WITH 'n''
1 • FROM FPL CONDUIT TO
4-8C/Lii BAGS OF SAKRETE.
1 FORM CONCRETE ADJACENT FOREIGN UTILITY WITH
1 TO POLE AND AT SURFACE. WELL TAMPED EARTH
1 GR,ADE---A
/. FLEX PIPE TO PASS UNDER
FOREIGN UTILE!YL,,- *"447,..‘9 OBSTRUCTION IF REQUIRED. ELECTRONIC
__OR OBSTRUCTION
---------.'-'--- __________-_-___-___-. MARKER ---,k I r
----..,---...,_ '4, __------ y
--,_,---_,
--- _
AS REQUIRED-
i
17 MIN. SEPAR);TION CF WELL TAMPED PARTH _ •
_...__
FPL CONDUIT CROSSING UNDEF.A FOREIGN UTILITY ---END PLUG
DUCT END MARKING
I N O_TE Si (IF REQUIRED)
• BACK-FILL Wi;1 IN 4" OF THE CONDUIT TO BE FREE
OF MATERIAL THAT MAY DAMAGE CONDUIT
SYSTEM (E1OARDS, ROCKS LARGER THAN 1" IN
i DIAMETER DEBRIS, ETC.) i
i * IF COMPACTION OF TRENCH ROUTE IS REQUIRED
i ,POR PAVING, ETC, BEGIN MACHINE COMPACTION %.,---1
;; :127/1
if;;'Z°'". '. i V'' ''''/ ;".%--;-•
C://
,'///',/,.;-:•._,>'',.."::-;:,
I 6" MINIMUM ABOVE CONDUIT. i
I • WHERE 36" OF COVER CANNOT BE MAINTAINED, z Fiii I , 1 ."2-MINIMUM
■ - HORIZONTAL
--1.1 ! 1-
30" OF COVER WIL I.BE ALLOWED WITH 3'OF ::, ..V
,,,.,,r, .9 1le I I ,1 f.1.4_\ .EARATION
CONCRETE ENCASEMENT AROUND THE CONDUIT.
, .
1 (N.E.S C. RULE FOR PRIMARY VOLTAGES) I
• INSTALL A CONTINUOUS LENGTI-4.OF PULL S-FoiG . ..FOREIGN
FPL I, / •,`, 2 Nor --
IN ALL CONDUIT RUNS. UTILITY
CONDUIT-----
I . - INSTALLATION OF FPL CONDUIT
MATERIAL UT 2" PVC SCJ-1_40 CONDUIT • PARALLEL WITH -OR-IN A SHARED TRENCH
20 LENGTH (BE] LED END) 164-33100-6 WITH A FOREIGN UTILITY.
90° BEND 24" RADIUS 164-23300-6
45° BEND 36" RADIUS 164-23.945-2
45° BEND 24" RADIUS 154-23900-2
STRAIGHT COUPLING 164-47000-6
REPAIR SLEEVE 4''LONG 164-47520-2 . FPL SUPPLIED 2" PVC CONDUIT
END PLUG 164-54500-5 / TYPICAL CUSTOMER INSTALLATION DETAILS•
ELECTRONIC MAKER F.:.)-615o....5 1 ,D( TintIS OF UN-5, UN-15, C;ONC & PAD DETAILS)
I --- Packet Page -1756- —
. 12/9/2014 16 D 16
18.0.0 UN- 18.0.0
FEEDER SPLICE BOX
— .
EYE BOLT FOR LIFTING
1" WA HOLE FOR ALTERNATE WHU.I EYE SO E
NATURAL GRADE LT IS
FOR SPUCING USE, PLAC
SEE DC S IJE-1 S.O CI, LIDS N. SEE NOTE 4 THE ORA-SS PLUG-IN
- .--------
0 444". / ....ar--- POSITION.
51';‘: ,,)V;•1 \ I / Y
i ----,>
--,----..--.
ii III 1 1 \
6." ID PVC
1 I
,,\.\\,,,,,,‘_
-.-___:,,-
,,.--' 6" iD PVC
ALTERNATE METHOD ---..„, END BELLS
--
OF CON ST RUCTION .4,,I F ill '..-.-.74111.• '
„ - r /
, ,
/ PU LL-1,4—IRO NS
--\--
....,--7. c., "4-----___ TYPE I GROUNDING
STEP RACK MT H 8" STE, -"INSTALL COP?ERWELD GROUND ROD
ANO 2-4" INSULATORS St'a G-17,0.0 FOR ? ROUNDING SPLICES.
TYPICAL WALL SECTION
— , .00111111111 ,
1
1 I I
3* 1 i 1 i
1 I
i L tiT I
• 0 I
En,
_
END VIEW SE VIEW
I
TOP VIEW TYPICAL FEEDER SPLICE BOX
m
[ s III RER DESCRIPTION t
..._____ ____
152-240-003 CONCRETE FEEDER SPLICE BOX & U . l
r
COI/CRETE FEEDER SPLICE BDX & LIDS COMES WITH SvECIAL BRUSHED
162-241-0D0
SIDEWALK FINISH UDS AND FLUSH IN/SERTS stnTABLE FOP PEDESTRIAN TRAFFIC.
POLYMER CONCRETE FEEDER SPLICE BOX. 70 BE INSTALLED ONLY IN NON ACCESSIBLE AREAS, NOT TO pH:.
1 152-242-203 '..;LIDJECTFT) IC ANY VEHICULAR TRAFFIC SUCH AS STREETS. PARKIIN-3, LOIS OR DRIVEWAYS.
•,,lollT,,,3: _______
. LEAVE SUITICIENT EXPOSED t3ROW11 ROD TO INSTALL 5 5.1:"1-1 44/2-0 C010.4ECiORS #3.5:S i",20-115-005.
2. DRDWID ALL sPLicEs PER DEORIBUTIoN sTANoArio o-17,10,,
3. GROUND ow,E RAC-,..S.
4. EACH &PIK:5 FOX is SraPP LEG. IT,TH 7-I" Mk NaLE rci!,,, ALTERNATF &:mut/a RCM LO'.-:Ar,cri. MANE ALL GiwuRcia: ratJe,-.7LioN5 GIsIt,'E T-!F B:Dx. p-...
FnENT AmouNT OF 4J0 TO LIAKE CONNECTION To ALT. :MOUND WW1 LEICATIut.L RESLAL 1' ERA -LOU WM ArIJILEAL
5,. DISIX9,,,Muil SPLICE pay.AND LIDS ARC F.A7.SIGHED FOP N-20 VEHICA LOAIENG. (ruLt.Tfm,Fil; ,..0ADN,ID)
6. WEIGHT Or SEIJQE BOX (W/0 005) ..0700 LDS. DIMENSIONS WE 10' X 5' X 41 LEP
7. wFJ,-.;KT OF EACH LID=1400 LBS.TWO 005 REOtARED. MI At S t)J FOR 00 ONLY 152-240-01 I.
R. 09? FEEDER CAL IE SPENCE& ILUET BE 5.050,F_Ei 70 DR1531 uNuUNDs.
B. REFER TO UE-19,1,1 44 ME-19U.2 FOP SPLICE .2. alln.Y. A WATER TIGHT srAL RUST BE AWL'S WHERE WV:Aim
10. CONDUCTORS CONNECT TO SysTEm NEUTRAL SEC (3-17.0 o
11. 1H MAXIMUM It39 LtssluLt. 0.1Proacci 70 SYSTEU HflITRAL FOR A DRIVE CP.OUNO 0 '25 OHMS,
:2. AS sRoWri ABOVE, THE PVC HAY ENTER uNo.a:NEA:1-1 THE!TLiDE Kix BY USING A 45 0-OPEC SWEEP. _.-1744. cDNID'Llif WITH 0001 SEA-
13. IN AREAS SUEL:ICT TO WATER IFr7RUSIDR, IM3TAL.1, A SUFRIEIENT S10UN1 OF PEA.RocK 1/4--3/4" SE'' PUCE TO AU OW FOR TI-IC FENcolAWNI OF THE
14, I. FEWER SPLICE ROX IS TO FE. [N5TALLED IN A SIDEWALK. A SEER/MON WILL FE NEEDED
BE,-FWEEN THE coNvtac AND THE 1105.
15, REFER 10 UX-213.0-1 la"F P L U
I G
OH gz U DISTRIBUTION SYSTEM STANDARDS N
I OWIRATCR: RAP I:AMR Ern 1. SHOUP,
0 F5,•'16/05 •ORIGINAL DRAVANG Rio E Jai DATE'0/27/99 A,51-5.10VE2: J. MeEVOY ND SCALE
— SUPERVIson', C4-14'UG PKWCT
NHET ET,---.; REWSI') VuG IgI.AwN APP R SIPIVRT s-,E•vic -;
Packet Page -1757- ,
,
12/9/2014 16.D.16.
..,....„
J-4.0 2 TYPICAL INSTALLATION OF 25 ICV J-4.0.2
S & C DEAD FRONT SWITCHGEAR AND
TIIREE PHASE PAD—MOUNTED CAPACITOR F3ANK
N.P.ms!
1. INSTALL 9P2' X 92' PRCCAZT PO 01 t. Z 1Ga-estoo-ro
a IIR1VE GROLCM WAS & ATTACH Q CU aRcum Ta GRIKNDIt& LUGS.
1 INS`TALL lJkD CAPACITIR i!,,NI‹ Of & S 223-39600-V UN PAIL
4. it,tzroAl. ROTA-WU FEED-THRL4 EASIIING Z'SkV (14 & Z 163-7-zaao-e) tyq rAcli Busii:Pc.
5, 1t4smii ?oo AK, ELEWS 1D4 PLITATA3LE rin-Thig LI Bustax.ss.
et,. IRTTALL :FEN/ ELBEIW iturvIESTEP,:, 'CM 1. Z 3:14-0t500-57; U.: ROTATALS FTID-P-RU $0S1INCS.
___.......,
. i.
• 1 I
•
I
tIn
, , J
k'ACIT3-1 CAENLI Z1.4r1C44 CAIIINET
1' la grO ■ I t-ft ' ItioN. ,-
[ ± i
IVILair
1 iiiiA.. .. 4 — 1 ' Mal f"."I rigaig10;11MtriPe.
= ti
---
g t4 if. I \ #
"'"V ,lif/
I j ____*1 '',..,,,,,t:!\\:„,.,,, ..,,,y
.---;--f '
—01
i -----;;5:---1-1-1'.1 'ANI\ 4-.. ,L...
' ---7,----------Ps ___:. ',--"-- -- l ;,' ,..., ;.,...„,,,, Zt.,,,,.„ ‘,..t......,;,,
.' ..i- ,,:.:5'' '''..)-",-
,.. --c----7.---1
,,,,.... ...„ • •-• , .....,•,
II I
'• I 1 .1
, ....---- _
II - ..,
[I
li
ti
_IL ?WO AL :P rsi,ILE.r,:
:+4 1-4• CONDO r
fit.Y.IN-A ar 1Z2 rtrr aF P L
• OH & UG DiSTRIKUTION SYSTEM STANDARDS
°wow-L.:Rt. IN ryklaili
1
1
1 1 mit r7/Pciot Arriara.t4 J.!, 4JCZ\tnY NO '-',70,..E
,----. - SixPum.-NOT.,-.01/113 eRarmcl
tin twTF. I 14 EMS IC IN I ORM 1 DRUM kr1■1-t, S:IPPOIC 5ERO.:ES
Packet Page -1758-
•
12/9/2014 16.D.16.
UX- 108 coNcRETE_FouNDATIoN UX-108
URD_CAPACITOR_BANK
7.:_ __ 1
..._
....,. 2. I
_......_ ---pl
,..„
. 1 _, 0 . . -.......„
\ .
u
A I
1 \
rp,c NtSERYS(4)
:Ft SIMI.•,,k•
i Al
'\
Vo o
0 0
/
I
ill
I•
1.1 _
\ •
\(\\\\.,
. '
./../17
L j
—
. ._....„,,,
I t __ B"
10,14LWall.14EftS IKatlEFICA1104,
— 4:' ".........-l'IC/".-** WAR Er Na441.11WITURE rIc Irl.
I OA&3 N.D.162-21,1W-fi
-'*---) 1:.:01 1.77:SrvjoiliP_:::: SiAID071-.! P1 AUG. 'IA
MAX A.I I VW 1E vARIATION IN P':-..10111 DE ZWt rk
, ANY tt KAM ON-315 fkIfirACT LS
) tr TO C
prg, git-LP/kW in%) 3. MAW1.11■4■CAIRT73 IUERVICMIGN, n Af I 0414D-
FACTJPE di M._ co. U tIO, 12-2.51 0 S-f, T0 IX
t'.AT IN 'In.'NiNF tXE OF P.O 1.4Ei+R 1..f-JV kJ< ( Kt-
,•5+ ,..,, ODP11..0 WI IL,1 PREC..43.1)
4•.,'' I tt $. SUPERIOR R 1,SLARLD in5rF1„ hietr $4;III IR lig,
/ 1 1..;1.r.;(In--W=14.'1D. 4 REQM‘ED,
,.,.
,
1-o-I ...•I 5 REIM 1.1,C1NG PODS TO RE V_..DVD M
A._=.1____ 1 AI 1,1 I Littlf taiotei
''''= r I Fl -----T-7\i'-1 —1
wE[arr 32 5•Z '-O
1 ! 1
i 1 I 1 I I 1 t. Fr.
CLI
„ W.:(LORZA 20DC LS
I VC _f I
[..._ _. _ ____ ;_____ _. .,
11 1 1 1 ? I,
&4014 14r7-4”
4t.15.," 31.5-5"
F
I
1-7 F :240',C 4.X1.-Ci
—
q;
. I 1 ill -. 4P-------
I 7
144- 4
t,---
I
i• /
c
4 .,—7 i 4 1
il /
16-1M-2
Ot 1
r r,
--
,t r.,
1 i 1 -- 1.:
ii*Z; •— ---=-- - - "----.:_. --r- --- "-,--, --'-,-------=''''
F 1) L
0H & JIG DISTRIBUTION SI-Silk' STANDARDS
CX-..74A":0;7:11L'S SENN
- DAIT..:12/ '07 ApPliovt: J.J. MCC:VC:11
, / . DRAWN Sr;r:0101-1LM,10
51D !CA11:
SLIHROISOR, 03 VLIO VADDLiCT
rill DATE ' RE11S1OI I OR16 ORM% AoPP1. StIPPOIZT 5:MVICI3
Packet Page-1759-
TYPICAL INSTALLATION OF 25KV S8c.0 VISTA 12/9/2014 16.D.16.
C-46.0.0
1 11/1 A/12 LOOP SAE ZA
NO SCALE
aT11,,,RmEnpEc„,17.07PHASE SWITCH FOR USE IN 13KV OR 231(V I
BELOW GRADE AND PAD MOUNTED APPLICAA.Tt.I40 NS
TYPICAL HUSHING PO,m,SvITIOLLNs 01,4‘44'10SDIT07A..:5St.iii.,91/TuC1H MODEL SHOWN
F,-FEEDER L=LATERAL
7-1/2- B f
i 2-S/4" 1- 4_1/2.•
1 1/2-13 NTT
—PNSERT Vg/ 16114iT C
-5"
—I I-
I FITEISt I' (4X)
Ii
_ — ,1„...*' •
...
•
*
-
F1 1 ,, - •
I ,.... _
Tott%11 6131Te`"----.--°-------- I r
WA (41(T2.'s,,,,,.. 37 --I
(t-: t•gi-XT1>", PAO/MI/4°31M BOLT I
s" "--.,
, DOWN INSERT
''''''..--4•.... LOCATION (41()
I / SEE 14016 17
'''‘.-•?.. A% .._ . ,, e--__ _—_
• 1 L
L ._. ..tt ,„-c°--
. -----11 7-1/4"
A
,-
' L4 14 L4 L3 L3 Ls rf.:. P2 P2 Fl r 1 Fl r
.... ..g
i*7„ ' ----1."""""7 7:7"--' ..----r=-717---- 23-1/2"
-E". FEELER CoNOLST i
72-1/2 DEaREE SWEEP
PNEIERRED =MON
EE NOTE 1G *i ID(1-. (1 t
ail* ... fr_ixi"----___Anstx;urcz frnmcv,E1
FM iticxeln cAstls
-,-
..,--
,-
GL ROND ROD —1' • 6,. 3/21.__ ________j
FREFENkrIT LOVCTION ..*--7.-.''' —a-rmstota
\-41-1/4' OUTLINE
1022.1.1Y Or..re't &NT CI-21.1,5m
13
Lir."P LOC", i ELDER FEEDER
;2,13:_rs CAE.E'S C.A!LES - CABLE'S
1 N.rkki F2 f140.4 Fl
1 1 I
l'ALI FiD1 I 130V144,,,, f j76-1/7* 1 ,..L _______ _ ..... PAI. ODLT D•01NN
sEc wilt 1,
1 2
% 1 --Tri
LT ____, , ..
, , . • .
_1 ‘, ______ --___.
__
• v .
„..,L, 103T6 6--.--------- -1 -11 111 '
_ _ ,
. .„
, . •
To Nan KAL ROND--- • • )
pair, co Lets hi 12-336-606 ' ”' i 00 00
-..-,........,........ .
,,,,...„0"......**
—
-----1*--- * 6-2- LOOP CONNAT ' ' ; * . -
. . 4.6 5E.76EL SENO • •
,
6S" . . . . .L ,
2-6- FEWER CC NOLNT-ji E-----—
22-1/7 DEG E SWEE -7..
SECT1014 A-Ac ErPsa vriN Dr. rAD
INSTALL DUCT SEAL F.:_•-P. /
UN-24,0 6 AND ClIAPIFi
._c N3Tr. 3 LicrvaLfgt FO3 CvLIE Tfft ASNIATIONS SW3c-1 Sax
14a, DATE
.1
RopsE7: cRi . OF Packet OH & UG DISTRIBUTION SYs-rEm STANDARDS
nikicurtATryt: A. F'AINTOORn
LE* SU°I-rtSr'S01?. US SF_RVDR:E714 BY E. SC1114-1,1141
vacKet Page -1760--
12/9/2014 16.D.16.
C-46.0. 1 I TYPICAL INSTALLATION OF 25KV S&C VISTA —4-6.0. 1
THREE. PHASE SWITCH FOR USE IN 13KV OR 23ICV1
BELOW GRADE AND PAD MOUNTED APPLICATIONS
TYPICAL VISTA SWITCH MODEL 422 SHOWN
Top VIEW OPERATION SIDE
±%1 FEATURES IN THIS ASSEMBLY
c
o :a------ IC) A. OVERCURRENT CONTROL
B. GAS FILL PORT
C. PRESSURE GAUGE
.
D. WINDOW FOR VIEWING OPEN GAP AND
GROUNDED POSITION or LOAD-INTERRUPTER
SWITCH OR FAULT INTERRUPTER
. 1 I — •
--------0.)
E. 200-AMPERE Bus HiNG-WELLS FOR
E7
FAULT-INTERRUPTER
I F. 600-AMPERE BUSHINGS FOR
LOAD-INTERRUPTER SWITCH
G. TWO-HOLE GROUND PAD
H. GOD-AMPERE THREE-POLE
LOAD-INTERRUPTER SWITCH WITH GROUND
I LI WU POSITION
TOP VIEW TERMINATION SIDE L OPERATING MECHANISM
J. MANUAL OPERATING HANDLE
K. NAMEPLATE
L. SUBMERSIBLE SF6-INSULATED TANK
' 1-SEE NOTE n 61. 600-AMPERE ALUMINUM BUS
N. BASE 9P.ACKET
1
--oi.67_47)".6:eA,6 ir.yet.7.11..vapj
TERMINATION SIDE
FRONT VIEW TERMINATION SIDEI ■
1 I)
j
I .
1
A--------' .
._,
___.----- -:::----7:-'—.-..--- -"-,- 7
1VD
i (Th K--'1\"---•
OPERATION SIDE
1 - ,-
_ 01 ,
li
D.t CoNNE c,7104 [7 :.'Av,
I I;-----,
`".ii t, ,
li
— \
2B-3/4 ,
of
i
L 11 ) \ --. )SEE NOTE 10 & 20
SECTION A-P..: FEEDER SWITCH OF P L
,
OH & UG DISTRIBUTION SYSTEM STANDARDS
OR ICINATOR: A. PANITOURES DRAWN By E. SCHLLItsK;
_1......11 .-46.0.2 10 C-W0.1 JGV ELS WM DATE 7/27/02 APPROVED: Ai NO SCALE
N3.• DATE 1 inIGION OT.G. DRAWN APPR, LEWD 57.1PMV.SOR, UG SERVECES
4 _
Packet Page -1761-
1
TYPICAL INSTALLATION OF 25KV S84C VISTA - - -
C—46' '0 2 12/9/2014 16.D.16.
THREE PHASE SWITCH FOR USE IN 13KV OR 23K.112"9"2014
DELOW GRADE AND PAD MOUNTED APPLICATIONS
TYPICAL BUSHING POSITION ON VISTA SWITCH MODEL 431 SHOWN '
F.,FEEDEP 1_- LATCRAL
[ 7-1/2" fl
......, •
1/2-13 NC
34-1/2" -- --INSERT W/ LIrTIND C
li
/ (4X) .
.10.
ii:'''''„'''>''' ' •
TANN
<-------- •
_.s,. _
DOWN (4 ) '---,,,,,,,,,,,,.. 37 _ ___ ___ _I r(F ''.. ,.. F'AD/ENTENSIoN BoLT
, DaWN 1112ER?
.s' ,,__ I[ ''- .." LOCATION (4X)
,,," SEE NOTE 17 I
44 "``. 17.------- A I i'
A - ' 1 ----7"----
II
._
A
1 1 ,
!...4 LA 14 F3 F.3 F3 ,I-2 F2 F2 F1 F1 F1
i I 1
nZ . MIN—_ — 0 ' 231/2.
3-6 FEEDI anuli ...
1
22-1/2 PER WE SWF_EP ,I
PREFD LOCATION
SEE 1101E 1 Et 1 rieFlYCX00) I
i
1 _Ii 17_t/4. ------A0DortuRSTAcABLjtaDcAoRACILE<ETs
I-
.,'
-'
I___,---
GROUND ROD I
E2 :1/2" \ CHAMBER
PREFERRED LOCA1 ION I --N-'" ' -EXTEN131,1
L ' -1J4' 79• OUTLINE
—
TOP VIEW 0,?..PAD AND r..11AMFER
rail:7R FEEDER FEEDER
LODE CABLES CAEIL. CA91_g_S
CABLES FRU F3 FROM r-2 FROM Fl
1
n-i/2 I i ' —r,AD BOLT DOWN
PAD DOLT 1.0111N-, •-• _ ..------- 111T NOTE 17
SEE NMI_ 17 • 62' I I ______
111
,
__.....
'''..,.:.^111 I
1
----.........
I " ' ------: --- .."-g----- 1 411 i.seille' ",' 2,1-- , .. - . .-' ' ' • - -- -
. . , .■ ,
,
1 .• " . 2 '_
Mild
VII ' ' i ■ -.1,
. '
• PS
1 -
1 ._ • i
1
1 -----
II 0 0"4'04°Jif TO NE UTP.11. (JUNO--- ' `
#.1/o CO I.1,6S ?I 12-336-033 ' v1P.711110:01110±-40.111111,4111040464...,
0...00 di-re' 4•00."-- . .
.....„..„„00:..0 ,. .111111111 , . ,
.. ,
. . '
• . . ' cse• — • --\\ . N•. - ---,
'a., .............
l'..1. 10 rv" cot 4o,ri-\
68" ' • - •
FEEDER CONDUIT / o •./
.....
22-1/2 DEGREE SW!: 7„.
SECTICEt.:_-_qnrs1. 1t5LQF P4D
INSTA LL DUCT SEAL ER
UN-1'5.0,0 AND CHAMAFP
EE NOTE 3 cia-....E TERM NATIONS SWITCH SIDE
GROUND ROD O 11 I,
PREFERRED F
LOTION 0I1 & UG DISTR,IDUTION SYSTEM STANDARDS
DRIONATOR: .1. ITALDES DRAWN 9Y: E. SCH1LUNC;
1 11/14/12 NEW PAGE DF C--l& ...IOV ELS WM DATE:1'VIE/2312 APPROVrtu WII„`I.,W. 110171.111 NO SCALE
143. Elin Rar.slar,t OR1' DR- - ---- LLAD SUPERVI33R, U. .5,---waLs
Packet Page -1762-
TYPICAL INSTALLATION OF 25KV S&C VISTA 12/9/2014 16D.16.
Ci -46.0.3
• • THREE PHASE SWITCH FOR USE IN 13KV OR 23KV
BELOW GRADE AND PAD MOUNTED APPLICATIONS
-.... 77-112
PAD •socry •
II
I D DM
, .
..,----,___----... •-'.'.,- _ C
it
.a.milicl.
.- •.--.: :.:,-- u ,i.
-... 1 \__ 1/2" DIA
(3OLT TO
SEE NOTE c- - 1... 7 --I RETAIN LIFT
CO SLING (4X)
.. ... „ •., _..
' ' •••;".• •
.. , .
. .
'• . . . ■
. .
•" ':':'''-;
. •.. • •-..•
.... . .. '•
• ':::*I,::::.•4;'t•:..: I ' "'s. - -,'...' .
. . . . .
. . - -..- - _ • .. . . •,. •• '..'. - •'.- ,.. -, -• * .• '• -■ .: ,
7,- • ' ' 55-1/4 ' . • ' . ., ,. -.. -. .. , . .
STOTIOU_I-J,
A. t..E.,p___AJD_SagA,U2
. ,
, .
. ........_,
......41.4.1....wo~wirix
=. : . .,_-___.--- ll* , ---•••-
• ,...
•• I
L.,
. .
• S.
IT,I
tl 1
L..1
! .1.
43
_ . _
i
L. 73 '!. ril •
SWITCH Eqc.,..,_ouRi-z.• stz vim .
1 01.
„II'
4:4)1/2* S'S BOLT AN CH
-1-t,....,— ............ .4. .
,,,,, WASH ER \.,. BRACKET i
gy 5-,&c . Euct_osuRr_
L. \ 1 ---1
,a111OFT LIMOS LIRE TOP Vit.*/
....:
t`...-1 MIN.--i \\,,.....
- FC.I., CON CR7E1
PACT
f„N
CLOSURE AN CHOR_11 Firrk
F P L L
OH & UG DISTRIBUTION SYSTEM STANDARDS
2faGNA7ort A. PANTOURIS DRAWN EY: E, SONILIM
1 11114112 CHAR3E C-4f.i.O,1 TO C.:-,W.0.3 ...r-V . Ias WM (Alt;7/27109 APPROVED: Ai LIVA NO SCALE
NO, DATE IiEwston ORIG. D . LEAD SUPEINISOR, LO SEFMCES
Packet Page -1763-•
TYPICAL INSTALLATION OF . 25KV SlicC VISTA Th 12/9/2014 16.D.16.
C-46.0.4 PIIASE SWITCH FOR USE IN 13KV OR 23KV BELOW ' `-' '''-" '.
GIZAI/E AND PAD MOUNTED APPLICATIONS
MATERIAL LIST
ITEM DESCRIPTION I OUANTFIY !Atli.z"-NUMBER 1
W4S CU
VISTA 422 (4 'WAYS', 2-THREE PHASE FEEDER GANG ! 1
I
SWITCHES AND Two.-11 I REE PHASE, INDIVIDUALLY 279--200-050 SW-VISTA-422-PAD
PROTECTED LOAD TAPS, WITH A STAINLESS STEEL
ENCLOSURE 1 ...
VISTA 431 (4 "WAYS', 3-THREE PHASE FEEDER GANG
. . SWITCHES AND ONE--7I IF:FE PHASE, INDIVIDUALLY 279-211-05D SW-VISTA-431-PAD
PROTECTED LOAD TAPS, WITH A STAINLESS STEEL
ENCLOSURE .
PAO AND CIIAMHER FOR PM DF VISTA SWITCH
• 2
(77" 79'X 40" DEEP)
1 162- 690.-790 PO-SW-W/W-vLsTA
X '
3 1600 AMP T-RODY EWOW ---05KV) VARIES 163-.-630--007 11.1-PDF-600-1K
....... ._
4 200 AMP HUSIIINGS (25l4V) • VARIES 1637804-001 SW-PD-SSH
5 ,200 AMF LOADEIREAK ELBOWS (25v) VARIES 163.-602-001 TM-RDF.---1/0
6 I PRGTEcTIVE CAP (15KV ONLY) VAR1FS i 63--02.2-000 TM-PDF-GC
_
7 ,El EiOW SURGE ARRESTERS (251,0/ ONLY) vArzirs 434-315-505 TM-POE-LA
.., _
8 GROUN:1 ROD CONNEC10R, CLAMP 'TYPE I 120-.0;i6-106 00-cLp-5/8
9 ..1 GROUND RODS, AS NEEDED VARIES- 1.ior-614-005 DO-PKG-.5/8
10 GRDON0 ROD COLIPLINGs• ViRIES 136L:405-104 DG-O-5/8
11 #4 COPPER WIRE. SOB 6 112-,300-00o
. ,
12 .4/0 CU CABI.E.:, 600v - 27 110-101-169 SW-PMD-GC
_____
___13 #4/0_RADII: CONNECTORS
14[COPPER 10 COPPER BOLTED CONNECTORS
- -- ------
ISTANDARD LOCKS
16 CABLE M Du NTIN 0 BRACKFT, STAIN!E' S
17 ROI:IS, SS, 1/2"X 1-1/2' FOR CABLE BRACKET
6 1.120.7E7i-005' (Oty - 1)
22 102-800-002
2 1 546,-245-011 SW-PMD-LOCI< 1
1163-31C-003
i 14O-515-557 sv; A LIT }14,,
12 - - -
1N,5?aitiq, NUTS S_S_, FOR 1 2 ROLT FOR CABLE 8RACKy1
19 I I 0Cr. Vq...SHER, 1/2 . FOR Cia_F: FIR4CI-CF7
201801 -AMP 1Ai-.IIJ INDICATOR VAPF'
21 ROVATAU EE
LE PD1 FIRLI DEVICE, 200AMP, 25KV
161-4E3-000
145-294-01D•
S 103-2.i"7-0091 P-CL-FC1-800
G 103-253-002) SW-V:STA-42_2-PAD!
hi I 163-253-302----SW-VISTA-4.31-PAD I
NOTES:
1. Pik INITRRUINIIT2S MUST' LIE PRE-SET 13y THE ERC, PRIOR TO BEING ISSUED 10 friL JOB. CALL 6,63-4.9.21 OR 663-4900 TO TAME
MiKANGEMEI‘II S. '
2, TIE PAIl r.400N11-.b ViSTA SWII C:t I MAY BE INSTALLED IN AREAS 511HJFT-1 TO rLooD[Nc
,l. SEAL THE INCOMING DUCTS Pi:R UN-29.0.0.
4. THE SIC1 CH AND ITS ENO OSURE MUST BE BOLTED TO THE PAD.
5, MIR 10 DGS 1111--41.0.1 FOR PROPER INSTALLATION OF 600 AMP I-BODY LLODWS.
6. FIO1.-1 THE 1 IEDER CABLES AND LOOP SIDE GABLES ARE TO BF RAcKED THROUGH THE CABLE SUPPORT BRACKETS INSTALLED ON THF
UNiSTPLF; IN THE CABLE 0liAmE4,7 .
I, CADL.:7; 1-AuZ,'T NOT TIE IN CONTACT WITH THE: CABLE CIIAMDER OR PAD TOP.
U. ',LUPO; 'Alf i ciLNI LENGTH OF CONCENTRIC NCLTRAL TO 'CACI I GROUNDING LIARS AND PLRI,II I THE FREE MOVEMENT OF PIE ELHO',./G,
S. MAKE Cii--RTAIN 01- r.:Af.-)..Es LAKATicirz OEM,---E URI\fru-, GROUND RODS, .
'0, APPLY CAULNING COMPOUND TO THE SEAM B;r3WEL-11 TH: EMLOSIIRE AND T",IE PAD TOP.
11, OUST o,,•,,r13 USED FOR cov1Rit,;;; DusiNGs AND EuSIIING WELLS DoRrNG sHIPmEN r PI in; Di 14OVR; PWOR TO ENEPCIZING THE
.C",W172.1-t.
2. UHLISED IOAII TAPS MUST HAVE BUSHINGS AND PROTECTIVE CAPS PISTA !'71
''.3 HOUSED FEFDER POSi1I013 1,ILIS;T HAVE DUO AVP pRomxmvt: CAPS INMAN II] (M&S E.1 G3-645-037).
14. Al ICR TIC :-WITCH ENCLOSURE H:3 BEEN INSIALLED. THE LIFTING IIKACKLIS 0 C.,',.;T DE F.:EMOVED AND STORED INSIDE THE 7NC-I OF;IJRC
FOR FUTURE. USE,
15. DISI IRE THAT THE WARN8F3 LAB-2.. (M&S #548-56o-lo4) 17. INSTALLED IN FiOTH TEIE• CABLE COAPARTMENE AND THE OPERATOR UT/ES
OF TUE ENcLDSur,E_
1 INSTALL EFEDER CoND LW'S AS 3HOW 1Z IN c-46.0 U /,',..9 C 4C.3.2 ON LOFT ANii/OR REAR SIDE (IF CABLE CHAMBER 13 ALLOW FOR
UENDINC RADIUS OF CABLE..
17. DOM FOR SECURING PAD TO CHAMBER FIE IN !_tr)ED FROM VENOOR, 1.1 irfer ARE 4 DDLTING LOCATIONS AS SH0,11,11.4 ON DRAvittic,s
18. INSTA11. 800 AMP 31, [AULT INUCATORS. ON EACH EFT OF FEEDER CABLES. :E-..E 1IV-14.0.3, UV-14.0.7, & LIV-14.8.2.
10. FUR PAD MOUNTED APPLICATIONS, THE BASE Bkikr-Kgs (TEET''), '"1.40 AS yierviN IN :''.-46.0.1 ARE REQUIR:i.:).
20. 'ME BASE BRACKETS ARE: NOT REQUIRED FOR BELOW GRADE C:UNDER-COVER") APPLISATIDNS, 8U1 SHOULD BE FEPT WITH THE s1I!T:3H
IN TI IE POSSIBLE EVENT OF FUTURE RC-USE, IN A PAD MOUNTED' APPLICATION.
21. INSTALL ROTATAIILE FEED-TitRU DEVICE ON THE LOAD Six OF THE VISTA SWITCH (14&S #1G3-250-3c2)
°F P L
OH & UG DISTRIBUTION SYSTEM STANDARDS
UPDATE NOTES 16 ,AND I 9 ADD ORIGINATOR: A. PAntc:II3iS DRAWN BY E. SCrELINC:
2 1 I/;4/12 NOTE 21 AND IT-J 1 21 .IGV El S WM
_
1 9/2/1D UPDATE iTELI 16
-—- -IP ac k et Page -1764-- APPMFD: AI ND SCN C
—
,ND. PATE Fr-DASION OHIO. x,,-1,,,.-1 LrAo. sUPERVSOR, tIC '...114,1CIS
.
Y'
--- 12/9/2014 16.D.16.
a tl
b
Gi
h
cl
cn
d•
H Li
1 �`f 1 ij 5
: 1 j .
p
w a7
t r
U m]y 4 d•Y�
• . ,./:)
; r-ga - -
Cr
N
Z 41 Q` A
n r-
riG7 T1
xj'll to
3 z.-4 f7
NritP.' \
4.
. l.•
, 1—''''
1
s___.1
,,,..
EL
@
MI
III! I
a,w E 'j . U) 1 rn c c+C] _� O p —I ur �H !T T a cos ri
.H
;,a' �� �
er'1,
-t-'
,:j . 1 J---- +
ril ��� is -�
�.
a r O O�?..,.._„" a6.7.....r.....77,..„... , , )g tL2fJY 0 . r_____::--I ....,_
_eo o
x As 1'C) z j
�
ci. -1-----
C ,.,.., tc3z il I 1 ,•-3 munktdio 2
ms 's, fir. D �l1 off a
ow n G '
n
c . , -
Packet Page -1765-
1-68.0. 1 OPEN WYE-OPEN DELTA TRANSFORMER BANK 12/9/2014 16.D.16.
USING SINGLE PHASE
PADMOUNT TRANSFORMERS
NOTES:
1 . POWER TRANSFORMER MUST HAVE AN INSULATED NEUTRAL BUSHING.
THE EXTERNAL GROUND STRAP TO THE CASE MUST BE REMOVED AND
THE BUSHING SHALL BE INSULATED WITH SELF BONDING TAPE dt ONE
HALF LAPPED LAYER OF VINYL TO CONFINE BONDING TAPE.
2. BOND TRANSFORMER CASES TOGETHER WITH #4 BARE COPPER WIRE DIRECT BURIED.
3. SERVICE CABLES FURNISHED AND INSTALLED BY CUSTOMER TO BE IN DUCT,
4. A DECAL WITH THE FOLLOWING NOTE SHALL BE LOCATED IN A CONSPICUOUS
PLACE INSIDE BOTH TRANSFORMERS. CAUTION: OPEN WYE—OPEN DELTA TRANSFORMER
CONNECTION; THIS TRANSFORMER CAN BE ENERGIZED FROM ADJACENT TRANSFORMER
(M&S #548-54800-7). REFER TO 2-35.0.0 FOR LOCATION.
5. SEE UV-12.0.0 FOR MARKING UNDERGROUND CABLES.
I
6. THIS STANDARD IS FOR TRANSFORMERS 167 KVA AND SMALLER.
7, LOOP SYSTEM SHOWN. RADIAL SYSTEM MAY BE USED,
8. DEAD END PLUG (M&S #163-10100-7) IS REQUIRED WHEN INSTALLATION IS
PERMANENTLY RADIALLY FED. INSULATED CAP ASSEMBLY (M&S #163-01800-2,
OR M&S #153-02200-0) REQUIRED AT LOOP OPEN POINT (13kV AREAS) OR
WHEN LOOP WILL BE EXTENDED IN FUTURE.
9. LIGHTING TRANSFORMER SHALL BE DEAD FRONT (36" HIGH) OR
LOW STYLE (24" HIGH) WITH HORIZONTAL TYPE SECONDARY SPADES.
MAXIMUM SECONDARY CABLE SIZE FOR LOW STYLE TRANSFORMER IS #4/0.
10. REFER TO 1-60, C-12, 1-52 AND 1-65 FOR MATERIAL DESCRIPTIONS.
11. ALL SINGLE PHASE 7620 VOLT TRANSFORMERS 167 KVA AND SMALLER ARE
ADDITIVE POLARITY, ALL 23 KV AND DUAL VOLTAGE TRANSFORMERS ARE
SUBTRACTIVE POLARITY. CONNECTIONS MUST BE MADE AS SHOWN IN DIAGRAM,
12. IF C.T. METERING AT TRANSFORMER IS REQUIRED, REFER TO K-26.
LEAVE PULL STRING IN METERING CONDUIT. 0.2
13, MAKE CERTAIN OF CABLE LOCATION BEFORE INSTALLING GROUND RODS
TO AVOID DRIVING THE GROUND ROD THROUGH ANY EXISTING CABLES.
14. FOR DUAL VOLTAGE OR 23kV NORMALLY OPEN POINTS USE 18kV RATED ELBOW
ARRESTERS. (RATING IS FOR PHASE TO GROUND VOLTAGE). REFER TO 1-52.0.0
AND I-65.1.1.
15. WHEN CONNECTING MORE THAN ONE CUSTOMER CABLE TO POWER LEG USE
HANDHOLE MULTITAP (M&S #163-06600-7).
16. THE NESC REQUIRES A MINIMUM OF 6 FEET SPACING BETWEEN RODS. IF ADDITIONAL
RODS ARE REQUIRED, REFER TO G-2.0.2.
1119
F P L
OH & UG DISTRIBUTION SYSTEM STANDARDS
4 I 8/01/01 URDATZD DRAwiNG ( -=1:1;EN.:ES) cJP JES &
3 g/4/1a9 MATED BRAI (TT) W DLW JAI CRIONATOR, J.V. DRAW BY: J.R,F.
2 W25/90 REED NO7E 114 LKO Aritip 107 FT6 .N HO RKC
gatixD mon its No I Gym DATE 1/1/90 AFPRC Fl C1ELO NO SCALE
SUPERvISOR. 041/LIG PRODUCT
NO. 1 DATE REYSION OR M. DRJ - SUPPORT SERVICES
Packet Page -1766-
1 ,
12/9/2014 16.D.16.
I-68.0.2 OPEN WYE—OPEN DELTA TRANSFORMER BANK USING SINGLE
I i PHASE PADMOUNT TRANSFORMERS
LIGHTING TRANSFORMER
POWER TRANsfoRletER
..,---0---- CD 1=3 X3 XI SEE NOTE 11
a 9
0
x3
,
g
-,. / ,=,;(=1. 4 HI. • 2 HI- •H2
SEE CONDUIT LOCATION IN IA 00i:c It SE,E
LOW STYLE TX. PAD OPENING — 1p //'X2 NOIL 1 '4 Z
1 % . POYFER TX. LIGHTING TX
i -.1 '
0 e"..----, it% e xz, • •X1 X3* 111-X1
SPLICE X2 x mit
1 li
SEE NOTE
FPL ti 15
GROUND ROD 7 lik 1 ip ': 1 1
ALTERNATE LOCATION - - ii" -.: z - ,
eitwoortair-twti'ar4Hrirt Tair
SEE NOTE #16 mr-- is li-k- fim
1,1 1 f4C SEE R-26
!! .'"'"" BARE ay* MR JI
i III -24:7 7 FPL
I t GROUND ROD
36- al ALTERNATE LOCATION
FPL srcoNDARY CABLE 1111111111111111111111111111 ENV 4' SEE NOTE 116
I (SEE TABLE BELOW) ji. mig a w -®Ash_ .....„ .
-----
33kii-ADDITIVE FOLARITY
SECONDARY CABLE SIZE GOVERNED ITEM QUANTITY IESCRIPTION (SEE NOTE 10) 618cS NUMBER
I
BY KVA OF POWER TRANSFORMER 1 2 . PAD MOUNTED TX. SEE NOTE 9
POWER
TRANSFORMER ALUMINUM C Lett
SECoNDARY SIZE 2 VARIES 1 ELBOW TERMINATOR: 15kV ELBOW 163-58700-7
KVA 25kV ELBOW 163-50200-1
25 1/0 TPX * 3 VARIES 1 COLD SHRINK TERMINATOR-SEE UH-34 163-51000-4
37-1/2 & 50 I 4/0 TPX • j PAD TX, (SEE UY-115) 162-24600-1
75 350 kontii 5 VARIES CONDUIT (FURNISHED dc INSTALLED
I VARIES
BY CUSTOMER)
i 100 2-350 kcrnii
• DISCARD NEUTRAL CONDUCTOR
LIGHTING TRANSFORMER
POVvER TRANSFORMER 0 -.... I= r1 1 x H1
(-4 . ____ ,,
xi 4,. ,
®----- mil i ti
x H I .H2 -H2
POWER TX. LIGHTING TX
CD CD
i
Xi- - •y,3 X1 VI x3
:
-
(D---eam....._-. 1 ` e—SEE
-- if ' NOTE 11 ,
FPL E::0 \ t : SPLICE
SEE NOTE C.T.'S If REDD.
GROUNU ROD rf I -'\.
' ,..• 0 i I•
. i 5
ALTERNATE LOGATiON , 't 1. SCE R-2
SEE NOTE 1;16 - xm,_. - I _ ' — . 1 . .1.-41
-' , l'PEC, 1 intAi ,SECONDARY
'sr-
ii 4 C
1 ' _
eg
/BARE BOND WIRE I 747.FRI, GROUND ROD :
1 ,H ALTERNATE
' 38 • -„:L°CATION
11=1.0iMEM. EL 14•
x
I Ahlinsim .._c)
. SEE NOTE it:6
; 28-1/2" PRIMARY
CONDUITS
. r 3 10 LOW sras TX
PA* P KING
23kV OR DUAL VOLTAGE SUPERSEDES I-€&0.2 LAST REVISED ON 9-25-90
SUBTRACTIVE POLARITY
NOTES: SEE 1-65.0.1 F P L
OH & VG DISTRIBUTEON SYSTEM STANDARDS
1
8/01/01 RE1.13vE REFERENCES TO DELETED SHEET WI JES IA
oRiciwrOR: RJD DRAIN 01 JED
REVISED CHART MR ITEM 13
1 9/3D/94 TO COLD-SHRINK TERMIMATOR NO JED I R..IS
0 1 9/25/90 ORIGINAL DRAWING wo 40 Rs DATE:9/30194 APPROvED: RA SALESKY NO SC.ALE
suPERvIsOR. 54/UG PRODuCt
No. I DATE nons.mx ORM. cer--1 tf,"• SUPPORT SZRVICES
Packet Page-1767-
CONCRETE FOUNDATION
12/9/2014 16.D.16.
UX- 1 15.0.0 OPEN WYE OPEN DELTA
TRANSFORMER HANK USING
SING-LE PHASE PAD MOUNT TRANSFORMERS
NIANIFACTUREWS IDENTWICATION.
YEAR ofr MANUFACTURE, & FPL
. CO. M&S NLVEIER 162-24600—I
...,"
. 1111110.411141111111‘40: <
1...t." 3'-4" 11117," 111111‘ "
,
3' 11.5' 11,5" 11.5" . 11 .5" 3 2-1/2"
_.-2....L.,, '--r
......,?...
1 1 I V
.,01"..11111111111.1:
!--"j--
S4O 4-i L - ; 74
'''----,,,,,,,e,:„.•;4
SylE" X f-SA"
ROLE PR Pi.A.,s*CIVARY
:
? :.,,, il II 540t1 g I I (NT raR rrripitow
M z
OND TV F GROUND
0
trt
1
j MITXL I
-A- I (i
I i 22- 1
78-1/2" 1 213-1/2' 1
7 "... •
I -
-
I 1
1`• CAtohfirON .orit SLOGS OF PAD.
wEIGHT: :B5D
L
CUBIC FEET:
. ”A.,
"A, L... LF:tt I .., es4 LUCA n EN OF INSERTS
,..
1
".. ,.r,1 ' ra -1-- ,. a i 1 ...._m_. .._,1 ,--,- : CUBIC YARDS; D52
I I
PLAN S4006
----.4.
/1M
P4 RE-BAR
/
, ., ...
4_
k.- •
- T 1;...:71] •-v-,:v.t
•...f
_
1" CHAP.:ER
SEET1ON "A—A"
NOTES:
1., TOP SURFACE SHIAU. DE A !....}4.0271I PLANE.. ThE MAXMLIM ALIOwABLE DETAIL - "A"
VARIATION IN HEIGLIT DETWEEN ANY TWO POINTS ON 11-HS SUR:ACE
IS D.125 INCHES (1175 rrirn).
Z. TIND INCH MINIMUM CONCRETE OVER REQUIRED OVER STEEL ON
SIDES AND AROUND OPENINGS OT FOUNDATION. A ciworac.,1,4 STEEL
3. "'ODD LEI, TEST CONDRE1E.
54053 —
4. DAYTON SUPERIOR TEREAUED INSt,--.RT, 1/2", WiTH PLUG, ELEGTRO— S40,19 — 9 REQ'D
CALVANIZED. EIGHT (F) REDUIRED. S4036 — 4 REQ'D
5. 1,1AWFACTURER'S IDENTIFICATION. YEAR OF MANUFACTURE
AND FPL CO. M&S NUMDER TO SE CAST IN TCP SUREK:IE O-F
ptz NEAR CENTER cw PAD. (714:5 IS REQUIRED MAIN .".•.,
.,
PRECAST.) F P L
REINFORCING ROOS TO BE VIELEED Psi' ALL INTERSECTIZINS,
MI & ITC DISTRIBIMON SYSTErvi STANDARDS
CRENATOR. RC? DUVFN FY.
2 I 513a/02 UPPL41E GarEWSIONS RAP ::ES •1•04
TE
L ovieroi UPDA TEXT JIM ailEYSIONS
PAP _CS Will I NTE` APPROVEC't .11. w.:-.Evor
SLIFERVEGR. OiluC, POD,IC'll
$ ORI .
0°,1 C: ()Packet Page -1768-
N3. DATE ' RD41 51.PRO,R1 SE UM'
CONDUIT LOCATIONS FOR OPEN WYE-OPEN 12/9/2014 16.D.16.
UX- i. 15. 0. 1 DELTA USING A SINGLE PHASE LOW STYLE UX- 1 10.1). 1
PAD MOUNTED TRANSFORMER AND A 10
P.EGULAR STYLE PAD MOUNTED TRANSFORMER
•
80"
. 11 SINGLE PHASE SINGLE PHASE
SLOW STYLE REGULAR STYLE
POWER TYPE LIGHTING
TRANSFORMER TRANSFORMER
SECONDARY CONDUIT TO LIGHTING TX
28 1/2" 28 1/2' I
LID t I
SECONDARY CONDUIT
—: i 0--*- TO POWER TRANSFORMER
SECONDARY! PRIMARY PRIMARY I
T !
' I
• 0 0--1 SEC 7„
I___ ...-.......
3"M AX 6.
' T.. 3„IV AY 'co
3 1/2"--
3"M AX , 11
I
(FRONT OF PAD)
NOTES:
1) REFERENCEI-68.0.2 OF THE DCS,
2) PAD M&S 162-24600-1.
3) ALL CONDUITS TO EXTEND 3"14,AX ABOVE GROUND LEVEL.
4) ALL SECONDARY /CUSTOMER CONDUITS MUST FIT WITHIN THE 10513”
AREA INDICATED_
5) ALL CONDUIT RELATED DIMENSIONS ARE TO THE CENTER OF THE DUCT
UNLESS OTHERWISE INDICATED,
6) MAINTAIN 81 CLEARANCE FROM FRONT AND 31 CLEARANCE
FROM SIDES AND BACK OF TRANSFORMER PAD.
..51-
1' P L
011 & UG DISTRIBUTION SYSTEM STANDARDS
: CFNGINIQCM: SIAS ElfauVN Ert: BILL
IDATE: APPR3VED: 1,1! t.C.:EVOY NO
SL4POrdi%:Ift, ON/L4 PRODUC1
NCI. MIT RIVIVON 5fila OR.■Packet Page -1769- suPPowr SE01111ES
UX- i1 5.0.2 CONDUIT LOCATIONS FOR OPEN WYE—OPEN 12/9/2014 16.D.16.
v..,is. X L %./. •Na
DELTA USING TWO SINGLE PHASE LOW i..1
STYLE PAD MOUNTED TRANSFORMERS
80"
h------ ..--
SINGLE PHASE
TRANSFORMER SINGLE PHASE
IOW STYLE
LOW STYLE
POWER LI GHTING
IRANSFORMER
SECONDARY CONDUT TO LIGHTING TX-----
\
,28 1/2" SECONDARY/CUSTOMER CONOU:1-5
28 1/2"
S I I- I i -
____ ,-----.., ,
0 0002 6"L'AX
a. I ,,..,,
t SECONDARY' PRIMARY 1 LA...73t....1—
w)
I ; i iPRIMARYI
i CP
I 8" i
I 3"MAX c 3"MAX r 0)
(FRONT or FAD)
NOTES:
1) PAD M&S 182-246D0-1.
2) At 1 CONDUITS TO EXTEND :5"MAX ArtOVE CROUND LEVEI .
3) ALL CONDUIT PELATED DIMENSIONS ARE 7.0 THE C7NTER
Or THE DUCT JNLESS OTHERWISE INIKATED.
4) MAINTAIN 8' CLEARANCE FROM FRONT AND 3' CLEARANCE
FROM SIDES AND EAC OF TRA,NSI-OM7R PAD.
F P L L
On & UG DISTRIBUTION SYSTEM STANDARDS
Oft:•1 NATOR: SUS DRAWN EY E ILL
DA I F.: APPROVED: J.J. MCEVOY !40 $4WE
SuFERv;EDR, oh/u PP=ocT
HO. I DAT: REmslcm.4 oRic, DRAVN APPR SUPPORT SEAS
Packet Page -1770-
INSTALLATION OF S&C TYPE ?ME-4 DEAD FR( '
C-39.0. 1 THREE PHASE PAD MOUNTED FOIE CABINE1 12/9/2014 16.D.16.
FOR 1.3 AND 23 KV MAXIMUM FUSE 200 AMP i
NEW DESIGN-SIX BUSHINGS ON LINE SIDE)
- ',....--- 4U" • .4.1 4
I
lie -:_71'_,,,,, 1 0
1---___
ft &An
U „,. T r
....., 4,1_, lit 4.., .. Ej _
6
1-- . ----- I mig •
_
2 ____
illegal
1 ,
C
# 1 k,, f
,
A
t4S 0 Ili\ It A
i it1111111111111 _ 1
Mal to
.., to 1
, 1 .p.4.D
.1,
1 Isi 4
. I -----1—
/---F 1 i---
' 1 ;
g I
7-::-
UNE SIDE SIDE VIEW ;
;
• 26'
52*
• MINIMUM
•LaAD SIDE I
vt,,,e,12,, 2. • ,SEE NOTE 2
-1:. ,,L6: 1,
01,.. 107 117::
1 !I: 111- rp. os. o,.., 3-2w FVC BY
‘,......„ ....., ,.,.. CUSIOMER WITH
ti, /.t, A1
I . 1 ) it
1
1 1 ,
I
170 T---- ___ . _`......7...''.. -11111,
1 '',.....'',...4''`..-.1.--",....' ''''',... 24- MINIMUM .-
,..., _..„.... 6. R.ki All'US 90 BENDS ...11
.... ......„,....., i ...„
-.. :.,',.:..,,,. .-.. 4‘...,,,...
-....„...1,-;‘,...
--.. .... ,......,,. ,.„
.,$
Ai a: 1 a it I Ili' I. 6'.r___40._,I
an '..k 0''..■.4::).N
•.■.•-^,.....-^-II
I a,
I I // Iii041r
CONC RO PA
/ M U : 3 TRANSFORMED
LOAD IDE 2- R
PVC (S1101'471) CR 5-2" PVC 70 s Ern. SEE IIX- I E.1.1
oursim PM) AS SPECIFIED BY FPL fi
LOAD MEE . CONCRETE I-,AD &' CUSTOMER
s FO N Pk( -4 rzE CAIINE,1` ,s
compiplEl 2
ri
is
LIES. DEE LIX-124.0.0 9.0
SEE -C-3 .2 FOR MATERIAL LIST AND NOTES
IViUG41:1 20D
7
covWNEF le P L
LINE SIDE '
OH & UG DISTRIBUTION SYSTEM STANDARDS
ill
,.,
2 4A/0S UPDATE NOTES CEA as IJM DRIGINAToR1 mota DRAWN 9Y.: RAS _
UPDATE DRAW TO NEW SIX
1 I/31/03 BUSHING ON UNE SIDE DESM; ct-A JES JdLi CATE: 6/09/96 44PPROVFO: J.J. MCEVOY 1,70 VA-E
SURERYI5/3R, 014/1.19 PRODUCT
Nil. cAlE REVISt01,7 Orr.Packet Page -1771- SLIPPIIIRT SERVICES'
I-70 0 1 TYPICAL CONNECTIONS 3 PHASE DEAD FRONT 12/9/2014 16 ID 16
..
SECTIONALIZING PADMOUNT TRANSFORMER - - - - -
J
7620/13200Y, 13200/22860Y AND DUAL VOLTAGE
USE CUP PRCA6GED BY
FUSE HOLD:R NANJKALIVRER D 1 S/B'
NOTE. .51JIAE
}V .... ,/ 0R WASIr 3 IcS klell- }5co-Ei
_1,1 ..im,/-
• • ,,,D, I V----,,,,-:7.--...ii 1--- f
,3 I 11,1 U 1 .,:..:S 1 7:.g'.•.:` r•r=--u-,,,j
..__, .
7 U 41 e
ti
nu I— 14
1 ,
N
OE 3- r
wri \D
... denDOWNIWIO
; 6 EIN1
I s fre
l• I
\
I ...,.1•1 II tiow AA N...:-.1111 la*.;:i.: N37 B..-----
I I■ :■"I '5...7.4 V ' \' c.v.,';,
.,
INSTALL All.
7----0.,.......1.... , '
CABLES IN ' ,7rvr-- virw
iP Q1-1 FRONT VIEW CONOLI1T 9
11-----G INCORRECT
FPL GROUND (IUD
/P°5511°4 IgTE8HO:ILDER WAY BE 7
-2" 1
up V_IFTERIZA4 400ATI ON
/ 1 DAMAG-71 BY IJD IN
NOORRE01- /,---:- ....-'---- THIS POSTION ___is . V
ri—i 1
POSNIUN I i ='i
. i
■ i ... CORRECT
-',..,,, : de"'POSMON Ffi
PRMAARY .... EEC,
: .
•
Fv,
NOIE #7 er,'
j
-,...
1 _ FI.ISE FM, GROUND ROD
4-- vtatn--R
-
f. L ,,E., ,,,,,. .,,,...4
SEE NO1E 6 — CON ORETE PAD - Pt AN 1•1E1N
c
'ITili QUANTITY I
1 - DEsorturrroN I
1 Mits No.
. _
I IFITININAL LUQ, N.INSER, SZt7 AN METAL 1 wpm
DETAIL IIA" Da; VNI OF F-tr- I 1,./ARtoUS
1-10I.1>EN EE NOTE ii) _________2 I ____- ,,Sr•IV• '-'•14-11-ES —
1,1BOW TERMINATO
1
2SkV WOW 1E3R,PSATOIt , 163-50*-Om
4 AS REO. CO*14ERWELD OROUND ROD AND DONNi.CTOR
4, ROOUIRET1.) FUR STD C;--2 I I • I
S 1 Cr:A NrOTOR CON PREIINCIN, KEARNIV I 120-111-001
#4 TO #5 E URN VY 120-12-000
6 6 CONNECTOR 0'0/AMES-SION, KEARNEY 120-112-0-57
- -_
I-C.R FY-1A L CON NFL C(IONS ? O CS #4 TO #4 %ail Dy 120-133-004
ST:E I-71 0 0 --
7 1 2 TRANSF ORMER TANK GROJND CONNECTOR 120-33b-UD5
I 12 0..t. weitc 6.-4c. (TARE - 112-309-MR
9 , : [PAD. 111ANSFORMER - ..P TO 500KVA 1G2-247-00B
----- I PAD, TR ANsron WM - 750KVA 277/42D5 I 1E-2-/tin-2.77
-- --- ____-..------
' 1 A EJ, TRANSFORMER - 750tiVA 120/2051: :6?-750-170 '
: 1 'I'M), 11 .) fORMEF 2 - 100.7K VA _
I 1112-1I10-0110
. ■PAC TP.A.NSFERNER - 2.5C.Cf.:VA 162 250-025
ON 3W 100P Ire.TILLATioNS .
USE I. 1-TvC CONDUIT WITH ID 1 3, (ND-r z) NEU-47n C:AP AS.liateLY -;CETAIL A;
1/0 F I,:i MANY TPX CAPIt I_
11 1 7 FT. 'WPF p:-.., BARE 117- 30N-GO3
1 ME-SSL,Itt RI raj DEtx_Lts 4/D-tr.12-00: '
:3 I 3 15 KY PARKFRC. STAND AESTE I 3:14-016-DRI
14 I 6 1113.S.-1 INS 1/IT t15,AcI 14.%-1161-O01
;75kV) 16-3-564-331
15 I 3 I 25kV FEED 7-.. 01.1'ai DEAC 1ED-OE 1-02 ,
15_1 r, ",, 18kY ELBOW ARRFr_STIR 334-0:5-e35
FURNISHED W.TH TIMSFORMI.R.
,.-
JFJO Ar 61 t.-D DRAWI:,, & ArJr .,
ED IstU... ; -,p-
F P L
5 I 9/2-1/35 NUMXR FOR Tx PRECAST' COW:RFT RAE
IS Rj° EIS '1'34 OH & IJG DISTRIBUTION SYSTEM STANDARDS
.----4. '3/7_2%04 UPDATE OR47.S.NC (1,aT) I LPY ELS FEU
3 _7/21/01 UPDATE DRAW NG (TEX') I RAP ,J ES &IA ; ;
2 11C/25/99 -tAT-'1) AS PiR S2E.0 7-2 l'-i; '5 1 WC DIAY J.AI 1 DR1 NAVA; WV DRAWN BY: RAS _
1 I 9/3c/94 rti.V.SEZ Dl1EK5,14 TD S1) t1Fli I kW RAS ..1JIV
C 1 112.9/62 OR 01¼'L DR NC 1 MI i Res JA; I RATE 6/9296 APPIRCV17C' .I_J 1,12EVOY _ , NO SCALE
St.IDEPvSOR Oh/E0 RI:)[;OCT
ND. [ DATE ‘11.7iP.3". — I CR.1: ![PR-A114'N AP"PR , S.Poara SERVICES
Packet Page -1772-
CONDUIT LOCATIONS FOR 3 PHASE
UX— 14.0. 1 DEAD FRONT PAD MOUNTED TRANSFORM-FRS 12/9/2014 16.D.16.
WITH SECTIONALIVNG (CABLE THEM UP TO I
15001CVA USING 2-5 DUCTS FOE? PRIMARY CABLES
BC)"
35" 19"
60" H 4-1
PRIMARY SEC
"c"1
0 0 CONDUIT
1 (Fr REQUi RED)
5"
MAX
13" 14"
(FRONT OF PAD)
NOTES:
,IFffrERENCE 1-70.0.1 OE THE DCS
2)PAD WES 152-24680—
3)ALL CONDUITS TO EXTEND 3"MAX A9 CRDUND LEVEL
4),ALL SECONDARY /CUSTC1EF CONDUITS MUST FIT WITHIN THE 19"X131"
AA INDICATED. WILL HOLD 5—4. CONDUITS MAX.
5)ALL CONDUIT RELATED D:MENalONS PRE TO HE CENTER DF THE DUCT
6)M A!NTA I N S' CLEARANCE FROM FRONT AND 3' CLEARANCE
FROM SIDES AND REAR OF TRANSFORMER PAD
F P L
011 & UG DISTRIBUTION SYSTEM STANDARDS
Dm.m.Nocrt, sus
I CI+17.Z t."1.2 uptsATE (RAmv5 ;Notc 4) 1 VAP -ICC LSI
AprsOVEM fiCC1/4f3tr C.") .-', "SLE
.SU--7PE1 UG PKKLICT
Mo. CIA7F t!CoiSION cric Packet Page -1773- SLIPP3R1' SERVIZS
t F
UX- 117.0. 1 CONDUIT LOCATIONS FOR SINGLE T rcr i n
PHASE LOW STYLE PAD MOUNTED 12/9/2014 16.D.16.
TRANSFORMERS
48"
SECONDARY PRIMARY
CONDUflS CONDUITS I
29"
0000 6"MAX
0000
13- 1
9 1/2"
3"MAX
(FRONT Or PAD)
NOTES;
1)RFEERENCE 1-65A OF HE DOS
2N?l,r) mals 162-24F00-4
.3)ALL CONDUITS TO EXTEND 3"MAX ABOVE GROUND LEVEL
ft)Alt CONDUI RELATED DIMENSIONS ARE TO THE CENTER OF 7-1E DUCT
UNLESS OTHERW.SE IND2C,:ATED
5)4.!AINT4.IN .9 CLEARANCE FROM FRONT AND 3 CLEARANCE
FROM SIDES AND BACK OF TRINS-ORLIER RAD.
1 P
OH 64 UG DISTRIBUTION SYSTEM STANDARDS
OfROINNTEFt SMS MAWR Ef Era
APPRWED: 1 MCEVOY
SCA,E
SUPERVISOR, PRM,E,T
RD. DAVE RSV:StON I ORG. Oft'."" `""-- SOPPORt Enot-m
Packet Page -1774-
1-65. 1 . 1 TYPICAL CONNECTIONS FOR 25-100 KVA. - -
10 LOW STYLE PADIAOUNT TX.'S 12/9/2014 16.D.16.
7620/13200Y OR 13200/22860Y VOLT
7—SEC. COND497S
SEE NCrTE 1
PRESSURE REUEF vALvE SEE NOTE 8 E
FUSE HOLDER
R3TE 1 0 1 O---- / . .
.
SEE OMR. "3 I, 0 .
, , .,.
.: ..1... . 3-
-.r./ WALL STREET
EA -- ..„„„
---. UGHT CARL! Z.M11157 • ••
...I
iis"--- \ 43
29 RI_ corcuirs
:.--.411411;.- 10 LOW STYLE TX PAD OPENING
coNcEtemc ma:■;:...-41411114. * cRouNo sTwx.P ;,,;•31.tta.01 CABLES
1•CIYIRAL5 0....,„ "gi.'41•6_41tii--+%.z,_•' ---:../ (DD POT REN3vE)
P4DTE 4 t
firAtIL.C'l P °
e
' t ,1 1.,.. '''' ,-.:, , •... . ...- ' .?
.. '.. I ZO . • , ...
. ,..... . ,.. ......r. Tr 0 I . t -.
-•-..:'. f D E 9 1 0 'II:'6
_.
". •' ... 1 .....4.• " '-. • . ...-r 0 .
-..---
II I ill ; () :: 0'.. Z I tt
.--SEE CONDUIT LOCATOR-
OW STTLE TX.
(4.9 4',..„ i I I 1 .'• Z IN L
i 510E,VLELV
•Z pAo OPENING uja
GROUND RCO 6., ,4
ALTERNATE LOCATOR •• 1••1
SU NOTE 6 TRENCH vtl
VI REM 3LIA4 TITY DESCRIPTION I u & S NO.
FRONT VIEW 1 3 uLL.T4TAP TERTANN. 23 - >5 l(Wi 103-50501-
100 KVA TOT-SC503-0
Ida. 2 — 1SERvICE CABLES VARIOUS
•0:70.4"1-g...1. .
3 2 -is KV ELBOW TERMINATOR
25 ry ELBOW TERaiNATOR 163-86700-7
163-50200-1
'4,51-rir,orr‘.11) s' cOPPERREW C.ROUND POD AND
45."0' 124:3 4 AS REM) coNNECTION-AS REO'D 130-61700-4 OR
•.,,,,- 4i6 iltN5__ ,e-,Q,, 130-61600-8
II
v. ,., PER STANDARDS 0-2
*
,\ ',..., CONNECTOR, COMPRESSION REARIIET 120-11200-7
ck, LA + ",.. 5 2
.- \ ,t-, \ ,,,, ,1 TO /4 MANDY 120-11300-4
LA i a 5- i cONNEGToR. TRANsFoRuER 120-33800-6
•
OT IEIL of:3A
IL....
TANK GRouND
1 \ --- 67 ,r, 92F7. . MIE. /4E, BAK i'2-30400-0 1
S.D6C.B.7 j """Cr. v -I a I Nu:), TRANS tR tit LE
FORT/ . S 0 162-24800-4
, iNsuLATED Cu,
NOTE 9 9 1(NOTE. 2) AssELIBLY (DETAIL-A) i2=1 14.1-17?`,`0:,!,
NMI. VOLTAGE: OR 23KV NSIKA.4 LOPFN FONT ID 1 CONNECTan, COMPRESSION KEARNEY 120-i I Too-I
14 TO 16 f3URNDY 120-13200-8
LOW STYLE IRANSFQkm5R —
WITiLELDOW RRESTEF .
12 I, PRESSURE RELIEF vALVE 473-83200-1
AS
13 3 FT.(NOTE 2) 112 1W COPPER wRE, will( 115-09300-8
14 I(NOTE 2) DEAD END PLUG (D(TAIL A) 163-10100-7
1, VENT PREsSuRE RELIEF DEvICE TO ELNJALIZE PRESSuRE iNsLOE is 2 IS x v
ELISHINE iNsERT 2N,.., 163-88100-1
TANK BEroRE REL0ANG 1-13 . REFER TO EL.1-M00 GE SURE THAT 153-86400-1
FUSE TS FULLY INSERTED wroi HOOK SToK RING LATCHED AND 16 2 FT. wn f6C emc f I I 2-30E100-1
POINTED TO THE LEFT, EEC DETAIL "B". 1 17 3 121txv FEED -{RV DENPOE -
2. USE CEAD ENO PLUG wNEN THE PithrARY ciR:UIT ENDS AT THE 1 1SO-00103-2
TRANsFORNEN. IF THE CIRCUIT IS A TEMPORARY CABLE END LEE I - r
AN INSULATED CAP. CAPS AND FLOCS WILL FIT ON ANY 28 2 I IliKv ELBOW ARRESTER 1 134-91s00-5
wustuFAcT0Rs DU5PIING. DEAD END PLUG AND INSULATED CAP trust BE
li4ONEED TO SYSIEU NEVTRA•L• (SEE DETAIL ''Al. •NCAlkALLY FURNISHED TWIN TRANSFORMER
3. PRILIARv CARLE SHOULD HAVE A nrGHT VOW" IN 'mat.
AssEmELED POSITIoN CALITION:
4. A,,.LOrr suFF101ONT LENGTH or NEURAL TO PERNG FREE uovELCKT 11)0 INCORRECT FUSE HOLDER
ro ELBOWS AND ELB3W ARRESTEPS. TEST WITH HOT sinc 11111#0 POsGroN MAY BE
PEfORE EN ER03:3,40. - \ DAuAGEO OY
/'• LTO IIII THIS
I 5. TrGHTEN SECO:MY BOLT ANT) LLANE SURE PADLOCK IS LOCI-SO. i., . POSITION
3
' ‘. .5_,Nc...N8 CORRECT '7. .' I, -:- -
G. MAKE CER7AJN Or CARLE LOCILTON iMeCRE RiSTAuING OROLIND 6-s,/ ! PosinoN I. NOM Zi4:T
RODS 70 AVE) OWNING THE GROUND ROD THROUGH ARV EKISTING 1.-.... NI,20;
C.ADLES. t"4711
SEE NCIE 2
7, FoR ()Luc, voLTAGE oR 2.3Kv NaNuALLY OPEN POIms usE 15AV
RATED Eteow ARRESTERS. (RATKvG IS FOR PHASE TO GROUND HOOK
V)LT04 0. 'Ng FICK RIND 4 t
B. NOT ',ORE THAN 8 SECONCARY / sERvICE CENDuCToRS PLL's t 5 TREET
LTC HT OR TEL/PORART SEANCE =RCMP:JCR ARE TO BE CONsECTED. DETAIL,:1," ruse , r'vn "If2d-rE
BOLDER ' FOqF IDLDE.5I1
9. BEND LODI" IN GROUND MIRE TO FORM ATTACHmENT KM FOR
TEIAPORART GROUND CUTAIPS. DETAIL:Eis-:
F P L
- 011 UG DISTRIBUTION SYSTEM STANDARDS
6 12/24/03 CHANCE ITEu I TO nv:WDE TOO KVA TX IA ELS I JAI 8:
5 113/01/01 plucro DRAWING TITLE & MINOR UPDATES CJ P _JES I IA
SifOil/In RELINE
DOOR & CHANCE CHAT wPC JES 1 Sad ORIGINATOR: PO Mow BY- ../N
- -
3/01/B9 ADDED LOOP (NOTE 9) c%13
2 1/04/88 LocADoN OF GROUND ROD CVS
DA 1/2/97 TE: APPROvED. JOSE R. DR1
I 1/02/8T 1 IT 4 REFERENCED 0-2 • -RO No wAi-E
suiPERVISOR ON InTRODuCT
NO. 1 DATE REVISION -CFFC, DRAWN APPR. suPPORY SERVICES
Packet Page -1775-
c.,.........____
1-65 1 2 CONNECTION OF MULTIPLE 12/9/2014 16.D.16.
. .
SECONDARY CABLES TO SINGLE I -
PHASE LOW STYLE PAD MOUNTED TRANSFORMERS
SEE CONDUIT LOCATION IN
LOW STYLE TX, PAD OPENING
PRESSURE RELIEF BELOW
VALVE
CLASS II FUSE
/ SEE NOTE 8, 1-65.1.1
1 1
C• 1 geel SMALL STREET
Lii- Ap • i Lo-rr CABLE 14MOM
.1-1-1- -3-4.,
ry-ri--.01
I
rb:1101 - Iran SERVICE
NOTE 9, ,r ,-,'--,- .-. _IC GROUND STRAP
• f„,,-„r.p , .,,,,e----(Do NOT REMOVE) -.''' e.PAD
I
,
If V'1 v1. * -,... .74.•4•• VS, z4 :4:zrltr.14.-4.m.7:1.4.. F ,...$) ,i1147.14:.t.•."lc:0:::A,'4 tiAr' „4.154-.:.i.:41.:2/4.4icikti.6'..:1
.1 I. ,7 ' 41.W.4z2fr-
11:11:-R95,,,A.A , • - I, 112E 4..151 -4
11 11
le "Ii • i -, , 'X..; • 2: 4. . 4 '4' - .. .A
. 1 '., - FR_ 1 1,
) .-. -.----475 GROUND ROD I.!. 0.. -
( 1 II '''
III .
LOCATION i
i
) - i -•• SEE NOTE 6 12:17 1/2=.1
.-,--TRENCH -- SEcONOAIRY 5..IDE VIEW
i ) crree__________!'CONE11JITS
FRONT VIEW -F,
— PRIMARY
o CONDUITS
I
—1-16 d 6131.0.(
1----29----jj .
10 LOW STYLE TX PAD OPENING
-: tiAC
No if
(e)., 16 ALLEN WRENV-I
7- US #594-94525-1
GROUND
* Ak.
WIS ON
TRANSFOW RE #6*
ER GROUND1
muLTITAR TERMINAL N,
(m.scs V03-80501-6)
THREADED Ill ...„- E" SET SCREv4
... TRANSFORMER
---. NIT 9
.... STUD lie\ ,--- o_v\.--
-.•;.•. PLAN VIEW OF FPL
. .. GROUND ROD
... NEUTRAL CONNECTIONS ALTERNATE
STREET LIGHT
-.•• N'NN-T611 \''---) (!:) LOCATION
.... CABLE OUTLET
..
. . -...
...•----- (SEE NOTE 6,
•V*■
... '1t-:E CONNEC,TION
iNsuLATiON
....;.' OUTLETS SEE NOTE 8. 1-65.1.1
. ,..
. ..,
eF P L
OH & UG DISTRIBUTION SYSTEM STANDARD
2 5/31/01 CHANGED DILE AND MINOR UPDATES GJP JES M MGM= PJC1 OaAwN er: CO
1 7/26/99 REMOVE DOOR WPC JES I am
0 6/30/9,3 GROWN. DRAWNO R..10 --— - —-1.3 APPROWD R.,' SALES-Kr NO SCALE
-Packet Page-1776- suPERviSCR, off PRilDir‘n
KO. DATE REvISON ORIG. ungwrdi moya.c.1 S1JPPORT SRVI
ECES
. I
- ,
_
TYPICAL CONNECTIONS SINGLE PHASE 12/9/2014 16.D 16
1-62.0.0 DEAD FRONT, 36" HIGH, PADMOUNT a
TRANSFORMER 7620/13200, 13200/22860Y
VOLT, AND DUAL VOLTAGE
u7 mg.mown Trr
..'TV (.17 V WAMa•C111.390.11 UR 1-o/A-
Aolt 1 / so *Ascii(1161-33doo-e)
la a
.1'.....1'',4•7:,it :e
1
c: 1 ® '...i ',.. c) I
., ,
1 moto WO 4:
wort A ,, ,,, : Aort I %FAIL
.. AbO T1 3
Acrt 3 1 ', Ot ICk.
.,...
.,
4
0 ...
, 11. -- '
■ . /
: ., : •"-yr , 0 -.
.. If
."-- ^'71. _...- irg ,.., , ,.-:.:.., ..t.„
..:.1 iv
' ,-v,,..,. c:6,..s.v.:1/1 " t,',:fic.s.•
, . .
--SCUM/14.1 CA&ZS I la CC:KW-••••••-•''.".''"--"---''''' \
:■-••-- .. .0 6 o
..; / , clues3PA
, /rm.clam woo
tr\ strAwArt u3auto4 0 rust Haw? wAx eE '
el ii■t(Wirt II
FriNT VIDI ......,.......1..'› ' C'E. YEW TATIAL3E0 Fir TX Di
'MS P2511170.1
--,... ..r. ,...,..fikk, it
44coRgtECI>
F.1')!:41.0;44 •0, ,..■....,
Pielt I ':'-efr iktk s e'e ' ''.•--- ,,
,
'
ili: '''', III 0 e . H a::0
....,
'‘kt., .... t‘c CORRECT rq... ..c.....
iv... p...... .,....,...
I II ram. I A 6;f 4 416 ill .
1 l'EXptil
II .
\ - .
III
MO Mr Or i'
IgISI.L.DS: 2.ILSLY0I-TACt faL2511...t1tta oPFPi MET Ftra HOUMA
SIX DOzt 11
Kat-FRONT IIMEEEZEILEJLEIDLELP2w ARREsnoS
-Dal QUisiir r1 Wee f .
—,-.
_....,:i ... ILL '..3.30, NUMBER, SIZE NO LEW- AS RECUIR ED. YASTOu5
t(2) 1 -- 1 SERtACE CAKES VARIOUS •
1• .)
1 1
2 WO* TERIPPIATCIZS 15 KIP 10-2700-7
25 13/ 1E3-50700-1 FAOrts:
1 I ;. toCHT PeEW,JRE ttotr 00ACE to EOLIALZC PreZS..SUR tHS3DE
,,D 1.As "intim cor...,--ERwaa OA.1) RC .0■0 CONNECTC 4 AS 133-ci 300-9 1 TANz BEFORE REw0Tok; 3-..TSE lank io LU-10.0.0 BE
REOLJFE0 PER 5WitA.Rti C-7 0 2 :a.,4 E eta First IS FY iwsERTED ww4 HOOK 5T1CK INC
LATC14EO AO KutiTat TO SHE TOT SEE DEJA% B.
A:EARNEw 1 1 2:3-1 I too-1 i
5) 1 0010TOR ECLIPREGSIEK /4 TO • mik..4.Dy 1120_13:v1_5, 2. LSE DEAD NV PU V.11141,IN DC AMORY [Avant'm ENDS AI twr
leues.TOPue& 1r TFt o r A.nu IS Tr aatory rev r two
0 1 2 CONWEGTOR CCUPRESSEM, f 4 TO /-.1 Kt.AF3.11V I 120-11200-7
VON DY 1 120-1 - CSC AN IKSAArEt1 CAP. CAPS AND PACs WEL FIT CAN AM
bLINACT(Or'S B.79404, DM DM Pm Apo INS1.1,..rEt) CAP
uuST BE EC...Ca 10 $17.TER PUP..
2
(72?)1 9 Fcci wilA.cYSF143:11,ER9AnTARK GROUND CONRCCTOR
I 120-35,00-5 3, pokuRt ca C SP Wa
RXRC rue< A fer BM.tA4 PHA.
1 112-30900-D Asaw13.133 POS■704.
4.rtilir SurMEArr lItC114 or AztutrAw. 10 PERIM FREE
(g, i 1 FAB, IRM.ISFORIA ER, SulOtE 1,,HASE„ LA-117 1 t E-.,2-2 4800-4 movg,:wEATT TO ELEM.
Cr) 1 ..I (NoTE 2) "
T5 KV y ;1 1leE33--M022O00 O 2 F sisza
. Cf CMAN Fg.took 6 1,00k-0,
or cAaLF itcATRIK Elesaizec •istr.:324c GAID(I AAD
RODS TO A/MO FiRre..4 THE ORURO R00 DROKADI AMY
1 ,(.I i) j I (NOTE 2) REA.DENC PLUS (DETRI. ''...') !103-101D.3-7 ExiSTIRD WILES.
1 0 1 2 BUG:gING AISFAT 15 K.I I 113-86100-1 7. ."..,AL OR PLUG AU auCTS, 11CrEe lo UN-22.0.13.
23 KY i T93-59400-1 & FOR W.O. vet TACE C 23Fv KOFIKALLT OPEx POW LSE
■jo 1 1 IPPESSURE WIIEY '6.C!..FE MIPPLIFI) ISIT1- Tp-nunt;'73Riir-R; 1 470- 0200-1 "Ini RASIO 11.-"ITS NIKIARS, ("TeG r-5 FOP.' la'REX I'll'AZ.
,-=.‘----- to VitOUwO...30,4C)
t;.4)I 1 ;STRKG.I..15 PAD:OEY., SLIAL.1. 1 54E- 4 500-3 9, Mwt sztorT too.In twouwo Ann TO tow Art.k...7-OsE147 PUNT
FOR TEL.POuRY GFroc.o.0 otAucs
13 fl CIRDTE 2) I:2 Twr CaPPER, whill 113-M300-,'
E;) 2 FEET 1 eTAE 16C, BARE ,112-3,z330_3 10. SEE M-11.0.0 FOR WRAC LKOEFOROUVO GAMES. .
ei) , z5 I FEED 13-IRU WPM
LEO 2 18 KV ELBOW ARR ESTL-0 334-315C0-5'
SUPERSEDES I-6 2.3.O .AST W.:MED CiN
F P L
OH & UG DISTRIBUTION SYSTEM STANDARDS
I .
oRicuvroR, .N DTuM BY. 1-1E1./1:10
Tam/DT., Urx'ACEtt w3tES TO seAti i's i Gin JES Pg. .
41N)194 ORARGE'D F4-. T 1 RAS i FMS KIS
c.
1 J., t 47.,L. F..„; rATF:0f30/04 APPROVEll RX, CIELO lis.7 SCALE
0 9/30/04. MG WA), DRAWN; t '" SUPETAFTSOR, 0.i/L1G g-NODUCT
No, DATE i REVIP 1 OR:G. MAW" ,411;21 5°,14 3A.1 surocts •
._.., •
Packet Page -1777-
13.X— 1 1 7.0.2
coNDurr LOCATION'S FOR SINGLE
PHASE REGULAR STYLE PAD MOUNTED
TRANSFORMERS 12-19/2014 76.1).-161.
...--- ,.. .
--I - - —
29"
L.-- -----....
55"
19" PRIMARY
EC. :
H3 I
i Il
• 0 0 9 1/2"
I
I
3 i/2" iiI"
.._
"MAX
(FRONT OF PAD)
NOTES:
1)RETERE N C'E I-62.0.0 01 THE DOS
2.)PAD 1,4&S 162-24800- 4
3)ALL CONDUITS TO EXTEND 3"MAX ABOVE GROUND LEVEL
4)ALL SECONDARY/CUSTOMER CONDUITS MUST FIT WITHIN 'THE 10"X13"
AREA INDICATED,
5)ALL CONDUIT 'ELA 1 CD DIMENSIONS ARE TO 1HE CENTER OF THE DUCT
6)MAINTAIN 8' CLEARANCE FROM FRONT AND 3 CLEAR ANCF
FROM 'SDES AND BACK OF TRANSFORMER PAD.
°F P L
on & I1G DISTRIBUTION SYSTEM STANDARDS
I
ORCINkTCE: Skr,..-., MANN t NJ
RIO SCALE
APPROVED; J.J. kliceray
..-—
Packet Page -1778-
SUPERVISOR, OP4,AKi PROCAJC7
Kn.. r.471: P,CVMIN ORM, ingioN *PPR.I SUPPORT SLItACEZ
MUL'IITAP CONNECTORS IN i
UN- 19.0.0 HANDHOLE (30"X48"X35") 1 12/9/2014 16.D.16.
FOR CONNECTING 2 TO 5 SERVICES
AND 1/0 PRIMARY SPLICE BOX
Y.P7.41/441'11i0'
MULTITAPS
\
A --‘ 48"
winommil*,
\••• '. , '1' 111111111111111111114 -.4"-- -4"- \-. \\ • r ....,
7 10°
ri -41111L--
.41=in A SECONOARY ----- appv. _ SERADE .
amommill IIMMII ■
MMON.4 - PIOMMEMO — ., ,—--:=....;T"."*" 7-r-7--._„. Sarifi .
mils. D=Pli..dog ----->-- --,---
--- esm.1
-
ift 4, FUSE HOLDER, FUSE
, lk,1%4„, & SEAL FOR STREET
•-...„, _ , 4,
- - .....-,__,
I-6 6,07, '`'..ty, 4. ,cc., RtOUIRED (DC'S 11-7.13.1)
•‘`-
NOT : KNOCKOUTS
WILL ACCOMMODATE FOR EASE OF INSTALLATIONS TRAIN THE CABLES
5" PVC 2 KNOCKOUTS ABOVE GRADE, INSTALL 11-1E MULTITAP CONNECTORS,
EACH SIDE THEN INSTALL INSIDE HANDHOLE
HANDHOLE ELEVATION CONNECTION DIAGRAM
(EXPANDED)
HANDHOLE USED FOR
SECONDARY SERVICE
//,----„,
\\// FP
(NYLON SUNG
LIFTING EYE /
pii.NIIIIIIIIIIIIIIIIIIk, ....-Arof.4., ./Ne
aIMIMIIIIIIIIIIIIIIIBk, '" :\° e''' v /..tivirtit .41a,6*
NOTE: FOR SPLICE
ir-t/O SPLICE DENIS SEE DM
36" I cci4 ,.TIL, g,, UE-19.1.1 & uE-i .1.2
,....,- pLuo--,,,...de,
\\\'-'---- LIFTING DETAIL
HANOHOLE MAY DE LIFTED WITH
- OR WITHOUT COVER IN PLACE
b......J hANDHDLE E_EVATON git NOTES:
I, MAXIMUM 1 SECONDARY COVIDULT VIIETH 2 TO 5 SERVCES,
FiANI)H0a." USED AS A 1/3 FRIMARY SPLICE BOX 2. MAXIMUM 3 SPLICES,
3, AlicA1IDE GROUNDING ;OR ANY RUN GREATER 71-CAN 1150 FT.
4„ 6-POR[ MULTITAP CONNECTOR V! & S *1E3-017-502
WILL A3COIMODATE CAB.-E FROM 1/0 TO 750 Ni044.
COPPER OR ALUYINLIV.
FgAMPLE: 5. WEIGITT:
•
FOR 753 SEAL 2 PIECE U3 --= 82 -SS. EACH
1 M1K11ECjff BODY --,- 190 LBS.
1BES1) HERE 6, LIFTIND:
I COVER MAY BE LIFTED WITH THE HANoiloLE I HD 1}FTFR
,.(1-ioolc) TOOL M&S #593-9,3D-021
,...r-Trgil
7. wOMDLETE YIANDickr, INCLUD:$ Dan hi&S b152-121-004
--
8. REP LACEF.I ENT COVER M&S #102-121-012
ii
9. HANDHOLE SHOULD NOT BE EXPOSED TO VEHICULAR
TRAFFIC, SUCH AS yiRaTs, PARKIN LTS„ OR DRVEdAyS.
13. FOR ca%Tv/AY LOONS IIANDHOLE '2-)' "X36" DEEP,
--TAPERED INSIX USE 1 f 162-127-892 (A-732.070)
APPROXIMATE WWII 2_663 LE:".„
MULTITAP CONNECTOR M&S 163-017-502
FLOOD SEAL SUPERSEDES UN-19,0.0 LAST REVISED ON 9-3044
F P L L a
U
OH 8: LTG DISTRIBUTION SYSTEM STANDARDS N
5 5/16/65 UPC.AE.,T NOTES RIO ELS
4 11/ aim UPDATE NOTES RJO EU J.,IM
/16/01 UPDATE DRAWING (NOTES) RAP JES LOW CRIMNATO. SUS CR 8v: 5-MS
2 9/27/$) UPDATE DRAMS (NOTES) RAP JES LIJM
CA 8/3:)/94 A.PPirieTh- J 4 1..11.,--VOY '
1 8/19/D6 ADDED EMS & N3TES 6., 1D, & 11 WS RAS .k114
5U.1..V1=:. fOlif.JG PRD0U"...T 1 '
NO. DATE RE4Ti0)N CRIG, DRAWN APPR. 51.1 P ram' sERVICES'
...-J ,
Packet Page -1779- ,
12/9/2014 16.D.16.
PROTECTIVE BARRIER AND PLANTING
UN-21 .0.0 CLEARANCES FOR PAD MOUNT i IJN-21.0.0
TRANSFORMERS AND SWITCHES
[
<(
LAJ .,,,,-- FIXED BARRIER
( ,...--CONCREFE PAD
1 7 i
A ALL FRONT
BARRIERS REMOVABLE
/7...r CONCRETE PAD
..-.
..f 7 ALL REAR
.74BARRIERS FIXED
/ trQ_ CONCRETE PAD
<z 3''-0" * 2. <z
5 MAX. TX. 3: c -.1 Tx.
------
0< 0 ..‹ -n TX.
z a. OR 13_
z ' Fa- ?:ii OR (51 OR L--' ..,
SWITCH y. cc L A z ,,_,-.c 1 r•
Le rr -.1
,t 0 SWITCH L_1
- 4. 0 SAI0 H
\\‘‘
\ FRaNT
...,/,
INSTALL ADDITIONAL
\\--REMOVABLE BARRIER BARRIERS AS REQUIRE.) I
DRILL 1/2" THRU Pt-AN,
HOLE FOR I IFTING 4" STD. C.F. PIPE WITH THREADED at. nu_ 4'. STD. C.I. PIPE WITH
CAP. (THREADS MAY DE SPRAYED WITH .....---
. CONCU.TE. LEAVE CROWN OE
10.. M&S #5D4-14,I 5D-4-.) ..„: CONCRETE
I PAINT PIPE TO MATCH -:
3'-(3" AN ----ir-thN SFORMER
,,, PAIN!'" PIPE TO M
3`-6" MIN. -.:. TRANSFORMER ATCH
3" /5" SM. C.I. PIPE SLEEVE
-- SLOPE CONCRETE FOR
i / .--SLOPE_ CONCRETE FOR WATER SHED .: -- WATER SHED
•
..
11 15 I 12
1"- :.
1
3'-3" '' 'I.% 2 -0" -.- . ...
, .
MAC 2.-0"
1). DOIJ
----; WELL TAMPED E..AX I H
X 8
1........_16" , _GALVANIZED 15"
WELL TAMPLD EARTH
REMOVABLE BARRIER
ELE D BAERIER
, 7-. './. -7;7; .---:T--,.. , - .
----) SECTION
..,..,..:....„-: „....._.,. .-.t., . , :1--i
........... _ ,..._._._ , „ ..,,........ ,....,
- 1
3' M
, N I SEE NOTE 1
..1 , .
\ CONCRETE' . ---, 1 - PADWUNTED fAVITL'HES REC.;RE 8.
PAQ
L, .
f, ,,-,
,-.. . ._______.
TX. -... ,
. ,
. .
-.^- M lq. CLEARANCE FRDN1 AND REAR.
2. "ELECTRIC EQUIPMENT-KEEP OUT" DECAL
1.1,11
* , OR
SWiTC:Ir I •
-;'.
, -,1 THAr SHOWS THE MINIMUM SEPARATION DISTANCES
L.
FOR BUSHLS /ROM TRANSI ORMERS IS M & S #5,8-5[3010 4
k ''.." 3` MIN. L,FRoNr 3' MINE
f
1 r
1 t,-Kel
,,
r 3' IMIN. 8' MIN t1,4
.. .
I, ..
t.
_,L.,•,,.1„,.."....._:;,:,,,,,,:.
.,--, •
• ...:. .----1.-, , ,,..,_. ,
-..2,..._,...•......_J .,,p• II
FOR F P I.., iLl
I-IOT STICK, OH & UG DISTRIBUTION SYSTEM STANDARDS I
1 i
---
2 7/1E)/0: UPDA:rE DRAWING (NOTES) L r i ,rES ,k6.41 CRI.:;14.42eVR: t.:114 t:RAWN EY: F1-1
' ..
1 B/271,,ig UPDATE DRAWING (NOTES) ; RA 1 ,is I J.IM
0 giliVE14 ORICANAL DRWING T UM i°Packet Page -1780
DRE,CIDR, =RUM■3N f_NMNE. It,
Na rIAT RTI1SMN I ORIC. 'ORAN APF',1 ANS ZibtRAIPONS SERViCES