Loading...
Agenda 07/08/2014 Item #16A 17/8/2014 16.A.1. EXECUTIVE SUMMARY Recommendation to approve an extension of two years for completion of Site Development Plan (SDP) improvements associated with Tenchitas Convenience Store (SDP AR- 14305) pursuant to Section 10.02.03 H of the Collier County Land Development Code. OBJECTIVE: To have the Board of County Commissioners (Board) approve a one year extension for the completion of Site Development Plan (SDP) improvements associated with Tenchitas Convenience Store. CONSIDERATIONS: On June 4, 2009, the Engineering Services Department approved the Site Development Plan (SDP) Tenchitas Convenience Store and the pre - approval letter was issued which started the developers construction period. The owner never paid the required impact fees; therefore, the approval letter was never issued. The owner has now paid the required impact fees and wishes to begin construction. Section 10.02.03 H of the Land Development Code requires that upon approval, a SDP must be completed within 36 months. The Code also allows for 2, two year extensions which the developer had not requested. Since an additional three year extension has been requested after the expiration date, the Board of County Commissioners must approve the request. The project technically expired on June 4, 2012. FISCAL IMPACT: The County will realize revenues as follows: Fund: Growth Management Fund 131 Agency: County Manager Cost Center: 138327 -- Land Development Services Revenue generated by this project: Total: $300.00 Extension Fees LEGAL CONSIDERATIONS: This item has been approved as to fonn and legality, and requires a majority vote for Board approval. - SAS GROWTH MANAGEMENT IMPACT: There is no growth management impact associated with this Executive Summary. RECOMMENDATIONS: 1. That the Board accepts the applicant's extension request together with the appropriate fees. Approve a three year extension until June 4, 2015 for Tenchitas Convenience Store (SDP AR 14305) so the developer may be in compliance with the time limit requirements of the Land Development Code. 3. The extension approval is subject to the terms and conditions contained in the original approval letter. Prepared by: John Houldsworth, Senior Site Plan Reviewer, Engineering Services, Growth Management Division, Planning and Regulation Attachment: Original Approval Letter Packet Page -398- 7/8/2014 16.A.1. COLLIER COUNTY Board of County Commissioners Item Number: 16.16.A.16.A.1. Item Summary: Recommendation to approve an extension of two years for completion of Site Development Plan (SDP) improvements associated with Tenchitas Convenience Store (SDP AR- 14305) pursuant to Section 10.02.03 H of the Collier County Land Development Code. Meeting Date: 7/8/2014 Prepared By Name: HouldsworthJohn Title: Site Plans Reviewer, Senior, Natural Resources 6/5/2014 2:17:39 PM Approved By Name: PuigJudy Title: Operations Analyst, Community Development & Environmental Services Date: 6/17/2014 10:13:17 AM Name: JohnsonScott Title: Manager - Procurement, Purchasing & General Services Date: 6/17/2014 1:26:21 PM Name: McKennaJack Title: Manager - Engineering Review Services, Natural Resources Date: 6/18/2014 2:30:24 PM Name: MarcellaJeanne Title: Executive Secretary, Transportation Planning Date: 6/19/2014 9:10:05 AM Name: StoneScott Title: Assistant County Attorney, CAO Land Use /Transportation Date: 6/25/2014 11:09:20 AM Name: FinnEd Title: Management/Budget Analyst, Senior, Transportation Engineering & Construction Management Date: 6/25/2014 11:59:08 AM Packet Page -399- Name: KlatzkowJeff Title: County Attorney, Date: 6/26/2014 4:56:54 PM 7/8/2014 16.A.1. Name: IsacksonMark Title: Director -Corp Financial and Mngmt Svs, Office of Management & Budget Date: 6/27/2014 11:03:42 AM Name: OchsLeo Title: County Manager, County Managers Office Date: 6/30/2014 8:23:25 PM Packet Page -400- 7/8/2014 16.A.1. June: 04, 2009 AIIM ENGINEERING 8c SURVEY, 114C L. J. LEWIS 5.500 LEE ISILVD LEHIGH ACRES FL 33971 (239)332 -4569 Re: Final Site Development Plans Approval .5DP -AR. -1430:5, TENCHITAS CON'V'ENIENCE STORE Project: Number: 2:005120021 Dear AIM ENGINEERIN10; ,& SURVEY, INC: THIS IS 'YOUR PERMIT AND MIDST BE POSTED ONSITE! Engineering and Environmental Services Department has reviewed the Final Site Development Plan for the referenced project and has no objection to the construction of water, sewer, paving and drainage aspects of the preject subject to the following stipulations: By receipt and acceptance of this approval, the petitioner acknowledges that a pre - construction meeting is required by, code for this project. If the pre-construction meeting is not held prior lo the beginning of construction, the project will be cited and shut down until the required meeting is held. Please call the Engineering Inspections Supervisor at 2.39- 2:52 -2403 to schedule a pre - construction meeting at a minimum of 48 hours prior to the start of construction. Even with an Earl!/ Work .Authorization a pre - construction meeting is required. General Conditions ]. CHANGES IN USE. ANC11OR DESIGN OF THESE SITE AND ACHITECTURAL PLANS ARE NOT' AU'rHOR:IZED WITHOUT WRITTEN APPROVAL BY THE COUNTY. CHANGES SHALL REQUIRE RE— REVIEW IN ACCORDANCE INITH ALL CURRENT COUNTY CODES INCLUDING PARKING FACILITIES, UTILITIES, TRANSPORTATION, ENVIRONMENTAL REQUIREMENTS AND THE LIEGE. 1. A preliminary inspection and approval of the infrastructure for multi- family residential must be done by Engineer Inspections prior to any Certificate of Occuparncy being granted. 1 Permits from other agencies hawing jurisdiction over this project shall be obtained prior to start of construction. 1 Please call 10r. Rudy Mass at (239) 25.2 -2391 to schedule a pre-- construction meeting a minimum of 48 hours prior to start of construction,. ]_ This Final Slite Development Plan is approved due to the issuance of a Certificate of Public Facilifiy Adequacy # < > with respect to Collier County Ordinance 93 -82. —'Packet Page -401- 7/8/2014 16.A.1. executed by the Owner with respect to Collier County Ordinance No. 93 -82 for Adequate Public Facilities. Be advised that building permits cannot be issued for this property until a Concurrenc ' Certifir„ate; is issued. 1 All construction activities permitted by this latter shall only occur during the following times: 6:30 A.M. to 7:00 P.M., Monday throUgih Saturday; no work is permitted on Sundays and the following holidays: New 'Year's Day, hAemorial Day, 4th of July, Labor Day, Thanksgiving Day, Christmas Gay 1 The review and approval of these improvement plans does riot authorize the construction of required improvements, which are inconsistent with easement of record. 1 Upon completion of the infrastructure: improvements associated with a site development plan„ and prior to the issuance of a certificate of oc:c:upancy., the engineer shall provide a completion certificate: as to the improvements, together with all applicable items referenced in Section 10.02..04 of this code including electronic, disk,. Upon a satisfactory inspection of the improverents, a certificate of occupancy may' then be issued. Zonin Conditions 1 SIGNAGE IRE:STRICTIIQhIS: Please Ible advised that any permanent sign (wall, ground, monument, directorj, etc.) requires a separate building permit and must meet the provisions Of the Collier County Land Development Code, Section 51.06, and /or the applicable provisions of the governing Planned Unit Development (PUD) (10CUITlent, regardless of any sign placement, dimensions or color depicted on the site and /or architectural plans approved by this letter. 1 All PUD related stipulations shall apply to this projiect. U_tilit _Conditions 1 See attached Exhibit "A" 1 Written confirmation ifrorn < > that the water /sewer facilities have been accepted and placed in service must be provided prior to issuance of a Certificate of (occupancy. z "APPROVAL OF THESE:: PLANS DOES NOT CONSTITUTE APPROVAL OF THE METER SIZ IE. SIZING OF THE METER; SHALL BE CONE WITH THE APPROVAL. OF PUBLIC UTILITIES ENGINEERING DIRECTOR OR, HIS DESIGNEE, BASED ON DOCUMENTATION RECEIVED FROM THE ENGINEERING OF RECORD. THE METER DETAIL SHALL. BE SUBMITTED TO ENGINEERING REVIEW SERVICE FOR APPROVAL PRIOR; TO INSATLLATION ". 1 No waiver or' sewer utility construction shall commence until proper DEP permits have been obtained. Subdivision Conditions Packet Page -402- 7/8/2014 16.A.1. All work shall be in accordance with applicable (,ollier rlounty ordinances and rules and regulations of other entities having jurisdiction over the project. Envir- onriont,aConditions 1 Site clearing is conditioned to the stipulations contained on the approved plans. 1 Required permits for listed species relocation must be provided to staff at the pre - construction meeting. 1 Silt fencing must be installed prior to any mechanical clearing. 1 Exotic: vegetation roust be removed prior to preliminary acceptance as required on the approved pllans. Water Management: Conditions 1 All work shall be in accordanice with applicable State or Federal rules and regulations. 1 Work area shall be properly barricaded with hay bales andi'or silt screens during the entire time of construction, to prevent any siltation during construction. 1 Separate excavation permit must be obtained. 1 The engineer of record, prior to issuance of a Certificate of Occupancy, shall provide documentation from the stormwater maintenance entity that it has been provided information on how the stormwater system works and their responsibility to maintain the systerrr. 1 This project: was /.c > was riot permitted by SF"'10D. 1 Whether or not this project was permitted by SFWPvI[l, dewatering shall not occur without a devMtering permit from the South Florida Water Management. District" Addressi ng_Conditions Pursuant Ito Ordinance No. 01 -62, no proposed subdivision„ street, building, condominium or development may utilize: the! same narne or a similar sounding name as any existing sjbdivision, street, building, condominium or development, except that the major street within a sjbdivision may utiliZe the name of the subdivision. Any changes to the project name shall be reviewed and approved by Community Development and Environmental Services Addressing Section.. Lands ing _Zonlditions At the time of F'relirnin.ary Acce;p.tance the (Landscape Architect shall certify that he landscaping h,-3s been installed in substantial accordance with the ,approved plans and specifications. The certification shall be in a form approved by the County Manager or his designee. Packet Page -403- 7/8/2014 16.A.1. Fire Protection Conditions 1 Please! note: that prior to the accumulation of c,Dmbustible building materials on site, proposed fine hydrants muist be operable with the minimum recluiired fire floss and improved stabilized emergency ,apparatus access ways (mien,. 20' wide) roust be available to within 100' Di the structures. 1 No fire appliances shall be obstructed, visually or functionally„ by vegetation. ,Add itional 2Anditaons; DEV REV CURRENT PLANNING I. On. site plan, s110IN location of proposed ground or pole SIGNI( "S) & FLAG:POLF(S) with setbacks & note on plan that these aTe to be approved separately review 1, 6/5/09 note as <<pplicable., DEV REV ENGIt H2O NIGVTVIT Stipulations for Approval Letter Right. of Way permit shell be submitted :prior to pre-constsucti.on meeting;. DEV R1EV ENGR UT:I:LITIE:S Stipulations for approval letter. 4121/09 This approval does not constitute appoval by Ininaolcalee Water & Sewer District. A letter of approval from IWSD must be- sribrnitted prior to scheduling the pre-construction rn.eetin;g. See attached inspection checklist for E0P improvements < > (< : >) sets of approved plans, < > (< >) sets of architectural plans and < > (< >) spats of landscape plans are beiing returned herewith for y,Dur uses. TWO copies of approved SDP shall be attached to each set of building plans submitted. i'wo co iie.s of the sared approved _�rr_hLecicxrsl _Plans _shall be submitted witch the Etuildin _FE ,,rrnii_ ARplic- ation_ It this it a_ si.rreultaneous submittal it is the applic:ant's resoonsibiii'hp to,inseiI the appraved architec_tu,rarrlans into the ,�uilciinp department permit set. Be advised that this approval automatically eXpiires thirty -six. (aG) nnoinths from the date of this letter pursuant to Collier County Land Development (erode Section 10.02.101:3. Please call me if you have any questions or need any additional information. >inf .erely, Packet Page -404- 7/8/2014 16.A.1. Stan Chrzainomfski, P.E. Engineering Review and Inspections Manager County Engineer cc; Property Appraiser (w /attach.) lE ngineering Inspections Supeaviscor (,w /attach.) Zoning Planning Tech. Mitch Riley, P.E., Principal Project Manager ASHLEY CA,SERTA, Pro *ect Planner Clustomer Services/Addressing (w/attach.) Engineering Technician D.O.R. Operation.,; Analys,t., Public Utilities Engineering (w /attach.) Engineering Utility Reviewer Building Review & (Permitting (12 plans Simultaneous Review) Fire Review > Outside Utilities SDP-AR- 14305, (w1attac:h.) Engineering Reading File Packet Page -405-