Loading...
Carlton Lakes Unit 3-ADATE: TO: FROM: RE: MEMORANDUM September 13, 2001 Maureen Kenyon, Supervisor, Clerk to Board Shirley Nix, Engineering Technician II.~ Project Plan Review Carlton Lakes, Unit 3-A Water and/or Sewer Facilities Acceptance On ,~- I t~r~ , 200_ The Board of County Commissioners granted-final acceptance of the water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded documents, in order: 1. Utilities Facilities Subordination, Consent and Joinder 2. Bill of Sale 3. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. 4. Owner's Affidavit 5. Attorney's Affidavit 6. Copy of preliminary approval letter from Engineering Review 7. Engineer's final payment confirmation 8. Certification of pressure testing of water lines by Engineer of Record 9. Bacteriological clearances (DER certification) for water facilities 10. DER Placement-in-Service letter for sewer facilities 11. Contractor's Final Release of Lien 12. Lab results on bacteriological test for water lines Memorandum to Maureen Kenyon, Supervisor, Clerk to Board Carlton Lakes, Unit 3-A Page Two 13. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 14. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 15. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 16. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 17. Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing 18. Certification of the inflow/infiltration test for the sewer lines by Engineer of Record 19. Coating certification of man holes, wet wells and dry well from manufacturer 20. Copy of video tape test report 21. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations If you have any questions, please call and advise accordingly. attachments doc:2094-2 Dwight E. Brock Clerk County of Collier CLERK OF THE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301 TAMIAMI TRAIL EAST P.O. BOX 413044 NAPLES, FLORIDA 34101-3044 ORIGINAL OFFICIAL RECEIPT When Validated BY: PATRICIA KD DEPUTY CLERK RECEIPT: 3524182 NAME : PAYOR: REFNC: SHIRLEY NIX/ENGINEERING BCC (113 138312 63 64903 PD: 3 DOCUMENTS DOC TYP FILE ID BOOK PAGE SUBORD 2861180 2896 3096 B SALE 2861181 2896 3099 DEED 2861182 2896 3102 DESCRIPTION RECORDING OF LEGAL INSTRUMENT P.R.M.T.F. RECORDING FEE INDEXING DOCUMENTARY STAMPS - 70 DOCUMENTARY STAMPS - 35 INTANGIBLE TAX SALES COPIES MISCELLANEOUS FEES INTANGIBLE PENALTY INTANGIBLE INTEREST RECORDING DEPOSITS REFUNDS AMOUNT 39.00 6.00 .7O DEPT: RECORDING TOTAL DUE: 45.70 PaGe 01 of 01 Prepared by and return to: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 2861180 OR: 2896 PG: 3096 RECORDED in OPPICIAL RECORDS of COLLIER COUNTY, 09/24/2001 at 03:04PM DWIGHT E, BROCK, CLERK REC PEE 15,00 Retn: SHIRLEY NIX/ENGINEERING REVIEW HORSESHOE DRIVE UTILITY FACILITIES SUBORDINATION, CONSENT AND JOINDER This Subordination, Consent and Joinder, given this Q-,~:T~ day of ,.Yr~tt~2~r~Y , 2001, by FIRST UNION NATIONAL BANK, N.A. (hereinafter referred to as "Mortgagee"), in favor of the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns (hereinafter referred to as "County"). Mortgagee is used as singular or plural, as the context requires. WITNESSETH: WHEREAS, Mortgagee is the owner and holder of that certain UCC-1 Financing Statement filed with the Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank, N.A., as recorded in Official Records Book 2128, page 1637, and as modified by instruments recorded in Official Records Book 2285, page 1534, Official Records Book 2375, page 2385, Official Records Book 2462, page 1661, and Official Records Book 2631, Page 1356; and UCC-1 Financing Statement recorded in Official Records Book 2128, page 1662; all of the Public Records of Collier County, Florida; (hereinafter referred to as "Mortgage"), encumbering the premises legally described therein (hereinafter referred to as the "Encumbered Property"). WHEREAS, County has requested and received from the fee simple owner of the Encumbered Property non-exclusive easements for the installation and maintenance of utiliW facilities over and across a portion of the encumbered premises legally described in Exhibit "A" attached hereto and incorporated herein by virtue of reference, which premises are hereinafter referred to as the "Easement Property." WHEREAS, County has requested that Mortgagee consent to, join in and subordinate its Mortgage to the interest that County has in the Easement Property to which request Mortgagee has agreed. NOW, THEREFORE, in consideration of Ten Dollars ($10.00), and other good and valuable consideration, the receipt of which is hereby acknowledged, the Mortgagee does hereby consent to, join in and subordinate the lien of its Mortgage to the grant of that certain easement described herein over, under, and across the Easement Property and any interest of the County in any utility facilities located therein or affixed thereto. Except as subordinated to the easement OR: 2896 PG: 3097 described herein over, under, and across the Easement Property or any utility facilities located therein or affixed thereto, said Mortgage shall remain otherwise in full force and effect. IN WITNESS WHEREOF, the Mortgagee has caused these presents to be executed the date and year first above written. WITNESSES: FIRST UNION NATIONAL BANK, a National Association By: PrintName: P_-.A.~L ~o'. l~Ret7T" Title: v~Ge-- F N~-st tl~w'7- STATE OF FLORIDA COUNTY OF The foregoing instrument was acknowledged before me this,~/~day of ~/~ 2001, by~49r~t__ /¥, ~>/?-~ 77- ,as V/oz t~>f~t~,qT' of First Union Natior~l Bank, a National Association. He/-~e is personally known to me , · ~ (Seal) .ary Public grint Name: My Commission Expires: 15891v1:06967.001 -2- *** OR: 2896 PG: 3098 *** EXHIBIT "A" All of the area designated as "C.U.E." of the Plat of Carlton Lakes Tract "3-A," as recorded in Plat Book 35, page 15, of the Public Records of Collier County, Florida. 15891v1:06967.001 Prepared by and return to: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 2861181 OR: 2896 PG: 3099 RECORDED in OPHCIAL RECORDS of COLLIER COUNTY, FL 09/24/2001 at 03:D~PM DWIGHT E, BROCK, CLERK R~C ~ 15.00 Retn: SHIRLEY NIX/ENGINEERING REVIEW HORSESHOE DRIVE HXT 5586 BILL OF SALE This Bill of Sale evidencing the sale and conveyarF, e~f the water at3d sewer utility facilities described herein is made this e;2.ff~, day o~"-'~'~ff."~~001, by NTC DEVELOPMENT, INC., a Florida limited partn-~(-here~rfferre, d t~o ~.~"_S_eller")and the Bo^m) OF COUNTY COMMISSIONERS OF COLLIER COUNTf, FL_,OffiD^, AS THE GOVERNrNG BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERN]~-BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns (hereinafter referred to as "Buyer"). WITNESSETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00), and other good and valuable consideration, to said Seller in hand paid by the said Buyer, the receipt of whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: See Exhibit "A" attached hereto and incorporated herein by reference. The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. OR: 2896 PG: 3100 IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. WITNESSES: NTC DEVELOPMENT, LTD., a Florida limited partnership Print Na}n~: pa~r ,,,~ By: SW FLORIDA PARTNERS, INC., a Florida corporation, General Partner By: ~~~ Robert G. Claussen, President (Corporate Seal) STATE OF FLO,RID~ . COUNTY OFC/"'~ The foregoing instrument was acknowledged before me this ~,7,~ day 2001, by Robert G. Claussen, as President, of SW Florida Partners, Inc., a Flo/fi'ff~}/corporaffon, General Partner of NTC Development, Ltd., a Florida limited partnership, o(.~behalf of the corporation and the partnership, who is personally known to me or produced as identification. (Seal) My Commls ~..j~lres: C{[eryl Rclb¥ ~'~'~;~ MY COMMISSION # CC695501 EXPIRES ~:~3~.'.'o--~ November 21 2001 >~ ~,~',~ BONDED THRU TI~OY FAIN INSURANCE, JNC 15888v I: 06967.0001 -2- *** OR: 2896 PG: 3101 *** EXHIBIT "A" All of the area designated as "C.U.E." of the Plat of Carlton Lakes Tract "3-A," as recorded in Plat Book 35, page 15, of the Public Records of Collier County, Florida. 15891v1:06967.001 Prepared by and return to: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 2861182 OR: 2896 PG: 3102 RECORDED in OFHCIAL RECORDS of COLLIER COUH?¥, ~L 09/24/2001 at 03:04PM DWIGHT E, BROCK, CLERK REC ~BE Retn: SHIRLEY NIX/ENGINEERING REVIEW HORSESHOE DRIVN EXT 5585 DOC-,70 15,00 .70 UTILITY FACILITIES WARRANTY DEED THIS INDENTURE, granted this ~/~ day ~ / ,2001, between INC., a Florida limited pg.q~sh~ (hereinafter referred to as Dy, xVELOPMENT, Grantor ), and the BOARD OF COUNTY COMMISSIO~~z'COLLIERtJ~ COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). WITNESSETH: That said Grantor, for and in consideration of the sum of Ten Dollars ($10.00), and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to-wit: See attached Exhibit "A," which is incorporated herein by reference; and said Grantor hereby fully warrants the title to said utility facilities and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A." Grantor and Grantee are used for singular or plural, as context requires. OR: 2896 PG: 3103 IN WITNESS WHEREOF, the said Grantor has caused these presents to be executed the day and year first above written. WITNESSES: NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW FLORIDA PARTNERS, INC., a Florida corporation, General Partner Robert G. Claussen, President (Corporate Seal) STATE OF FJ~ ~/~. '_ ,. COUNTY ~ The foregoing instrument was acknowledged before me this ,~..~ day 2001, by Robert G. Claussen, as President of SW Florida Partners, Inc., a Florisk~9~ration~s Sole General Partner of NTC Development, Ltd., a Florida limited partnership{'w_~4 is pcrs0d/ally. known to me or produced as id~ltification. (Seal) ~v~iyn~od&~on~E~ 15889vl: 06967.001 Chewl Raby MY COMMISSION ,f CC693501 EXPIRES November 21, 2001 BONDED THRU TI~OY FAIN INSURANCE, INC. -2- *** OR: 2896 PG: 3104 *** EXHIBIT "A" All of the area designated as "C.U.E." of the Plat of Carlton Lakes Tract "3-A," as recorded in Plat Book 35, page 15, of the Public Records of Collier County, Florida. 15891v1:06967.001 This instrument prepared by: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 OWNER'S AFFIDAVIT STATE OF/J~ ~.A COUNTY~F~y~-~ On this ~ day o~ , 2001, before me personally appeared ROBERT G. C~--~-SSEN,/~s President of ~ Florida Partners, Inc., a Florida corporation, as Sole General Partner of N~.,D~VELOPMENT, LTD., a Florida limited partnership, owner of property, to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of water and sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to the owner by, or is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant further says that the utility facilities described herein are encumbered by, or subject to a UCC-1 Financing Statement filed with the Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank, N.A., recorded in Official Records Book 2128, page 1637; as modified in Official Records Book 2285, page 1534, Official Records Book 2375, page 2385, Official Records Book 2462, Page 1661, and Official Records Book 2631, page 1356; and UCC-1 Financing Statement recorded in Official Records Book 2128, page 1662; all of the Public Records of Collier County, Florida; Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee to hold the Board of County Commissioners of Collier County, Florida as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District, harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A." NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW FLORIDA PARTNERS, INC., a Florida corporation, General Partner Robert G. Claussen, President (Corporate Seal) STATE OF FLO~"~.~,/7.. .' COUNTY OF The foregoing Owner's Affidavit was sworn to and subscribed before me by Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporation, General Parmer of NTC Development, Ltd., a Florida limited partnership, on behalf of the corporation and the parmership, who is personally known to me or produced as identification. (Seal) WITNESS my hand and official seal this ~ day of ~~.~_o4.J.~", 2001. ~otar~ Pub~ - ~-- ~ Printed Name: t3~ m'tat~/' My Commission Expires: I 15886v1:06967.001 .,,,;..:... g%.,~;~ ,~, Cheryl Raby .~.:;"~I~'~:.~ MYCOMMISSION# CC693501 EXPIRES ~#,.~ November 21, 2001 -2- EXHIBIT "A" All of the area designated as "C.U.E." of the Plat of Carlton Lakes Tract "3-A," as recorded in Plat Book 35, page 15, of the Public Records of Collier County, Florida. I~csted ~n flies in 15891v1:06967.001 This instrument prepared by: C. Perry Peeples, Esq. Garlick, Stetler & Peeples, LLP 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 59%7088 ATTORNEY'S AFFIDAVIT STATE OF FLORIDA ) COUNTY OF COLLIER ) On this /t--/~day of {~/10, t'~ , 2001, before me personally appeared C. Perry Peeples, a licensed attorney authorized to practice in the State of Florida, to me personally known, whose current business address and telephone number are Garlick, Stetler & Peeples, LLP, 8889 Pelican Bay Blvd., Suite 300, Naples, Florida 34108, (941) 597-7088 (hereinafter "Affiant") who, being duly sworn on his oath, does say: 1. This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District, to accept the dedication or conveyance of water and sewer utility facilities located within or upon the real property described in the attached Exhibit "A," which is incorporated herein by reference, said land being located in Collier County, Florida. 2. The Affiant has examined record title information to both the real and personal property referenced in this Affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 3. The record owner of the real and personal property described herein is NTC Development, Ltd., a Florida limited partnership (hereinafter "Owner"). The Owner acquired record title to the subject real property by instrument recorded at Official Records Book 2106, page 321, Public Records, Collier County, Florida (copy attached). 4. Affiant has examined-partnership and corporate information obtained from the Secretary of State. The Owner is current and active within said state, and is currently authorized to do business in the State of Florida. Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporation, as Sole General Partner of NTC Development, Ltd., a Florida limited partnership, is authorized to execute the instruments on behalf of the partnership in conjunction with the conveyance of the subject real and personal property. 5. The subject real and personal property is encumbered of record, or is the subject of financing statements filed in the Public Records of Collier County, Florida, or the Office of the Secretary of State as follows: UCC-1 Financing Statement filed with the Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank, N.A. recorded in Official Records Book 2128, page 1637; as modified by instruments recorded in Official Records Book 2285, Page 1534, Official Records Book 2375, Page 2385, Official Records Book 2462, page 1661, and Official Records Book 2631, page 1356; and UCC-1 Financing Statement recorded in Official Records Book 2128, Page 1662; all of the Public Records of Collier County, Florida. o Affiant further states that the information contained in this Affidavit is true, correct and current as of the date this Affidavit is,~given. C. PERRY/PEEPLES STATE OF FLORIDA COUNTY OF COLLIER The foregoing Attorney's Affidavit was sworn to and subscribed before me by C. Perry Peeples, who is personally known to me. WITNESS my hand and official seal this Iq H4day of /T/('~_f(~!h ,2001. (Seal) Notary Public/ ' - ' Printed Name: My Commission Expires: NSClients\NTC Der LTD_0204~Attomey's Affidavit-Carlton Lakes. DOC -2- EXHIBIT "A" All of the area designated as "C.U.E." of the Plat of Carlton Lakes Tract "3-A," as recorded in Plat Book 35, page 15, of the Public Records of Collier County, Florida. COLLIER COUNTY GOVERNMENT COMMUNITY DEVF, I,OPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 June 19, 2001 Mr. Jim Carr, P.E. Agnoli, Barber & Brundage, Inc. 7400 Tamiami Trail North Naples, FL. 34108 Re: Carlton Lakes Unit 3-A Dear Mr. Carr: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, John R. Houldsworth Senior Engineer cc: Daryl Hughes, Engineer II Shirley Nix, Engineering Technician PHONE ~ 941 ) 403-2400 FAX (941 ) 643-6968 www. co.collier, fl.us COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION June 21, 2001 June Miller Agnoli, Barber & Brundage, Inc. 7400 Tamiami Trail N., #200 Naples, FL 34108 Re: Carlton Lakes, Unit 3-A PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Dear Mr. Carr: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, Engineering Technician II CC: Joe Cheatham, Wastewater Director Paul Mattausch, Water Director Lisa Taylor, Public Works John Houldsworth, Engineering Review June Miller, ABB PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us Illlll~ lmmml,~, l~lXlUl~l mmmmmkT~ IIIIII!.~ · IIIIIII61'~ IIIIIII1-~. ~ ~ lmmmmmmmJ..)~u r~ k)tk~,J~, ~c. ENGINEER'S FINAL PAYMENT CONFIRMATION The undersigned engineer of record of the project known as Carlton Lakes 3A hereby confirms that the firm of Agnoli, Barber & Brundage, Inc. has been paid in full by NTC Development Ltd. for labor, services or materials furnished in the design, permitting, and construction of the water and sewer utility facilities within this project. This confirmation of payment is not a release for any future right to claim a lien for work performed in connection with the property. James A. Ca_rr, P.E. Printed Name STATE OF FLORIDA COUNTY OF COLLIER On this ~?h day of ~'g'~e. tY~,~)t ,2001, personally James A. Carr, whom I know personally and acknowledged that he executed the same. 1-764j 1 .cert Public Printed Name: June A. Miller lllllk~ Ii1111 Illlllk'l'~ i!111111'~ PRESSURE TEST REPORT PROJECT Carlton Lakes Tract 3A, PN 6696-3A/X002 DATE 1/23/01 WITNESSED BY Jim Bailey / Randy Casey TYPE OF LINE: FORCEMAIN X POTABLE IRRIGATION FIRE DIAMETER 8 INCHES, D LENGTH 1875 FEET, S TEST PRESSURE 150 PSI TEST: START 157 PSI ~ 10:00 a.m. STOP 157 PSI ~ 12:00 noon AMOUNT USED Zero GAL AVERAGE PSI 157 ALLOWABLE LEAKAGE: L = SD>P/133,200 GAL/HR = 1.38 GAL/HR X2= 2.76 GAL/2HR PASSED Yes ~~ Department of '"" I P ti Environmenta rotec on ~~~--~_--2:-::-2~:~- Sou~ District Jeb Bush P.O. Box 2549 Governor Fo~ Hyers, Florida 33902-2549 March 8, 2001 David B. Struhs 200~Secretary REC£~v£D Robert G. Claussen, Managing Parmer NTC Development Limited 6025 Carlton Lakes Blvd. Naples, FL 34110 Re: Collier County - PW... Carlton Lakes Unit 3A Water Distribution System (Collier County Regional WTP) 145371-004-DS Southwest Coast EMA Dear Mr. Claussen: This acknowledges receipt of certification that the subject water distribution system extension has been completed in accordance with the plans and related materials permitted by this agency under Permit Number 145371-004-DS dated October 27, 2000. Based on this certification and satisfactory bacteriological results, we are approving these facilities for service. Your continued cooperation in our water supply program is appreciated. Sinc.erely, O. James Oni Professional Engineer Water Facilities OJO/MFJ/klm cc: James A. Carr, P.E. Thomas E. Kuck, P.E. "More Protecdon, Less Process" Printed on recycled paper. Florida Department of Environmental ~Y Twin Towers Office Bldg., 2600 Blair Stone Road, TallahaSSee, Florida 3~-~2~00 * ' '~'Ot~_ DOMESTIC WASTEWATER COLLECTION/TRANSMISSION SYS"I'E'~,~, CERTIFICATION OF COMPLETION OF CONSTRUCTION INSTRUCrIONS: This form is to be completed and submitted to the Department, prior to placing the system into operation. A collection/transmission system should not be placed into operation without prior Department approval. All information is to be typed or printed in ink and all blanks must be filled. Construction Permit No.: 50581 Dated: 10/06/00 Name of Project: CARLTON LAKES UNIT 3A Name of Owner: NTC DEVELOP[IENT L£MITED Name of design engineer and Florida registration number (if different from the engineer signing certification): SAME Date(s) connection to existing system or treatment plant: Treatment plant serving project Name: NORTH COUNTY REGIONAL WATER RECLAMATION FACILITY County: COLLIER DEP Identification Number (also known as WAFR or GMS Substantial deviations from the approved plans and specifications NONE City: NAPLES Number): FLA 01.~139 if required): DEP Form 62-604.300(7Xb) Fl[cc'live June 1,1992 Page 1 of 3 WAIVER OF LIEN KNOW ALL MEN BY THESE PRESENTS~ that Timothy C. Mitchell, Sr., as President, of Haleakala Construction. Inc. for and in consideration of ONE HUNDRED FOURTYTWO THOUSAND FIVE HUNDRED SEVENTYFIVE DOLLARS and FIFTY CENTS ( $142,575.50 ) and other good and valuable considerations, lawful money of the United States of America, to me in hand paid, the reciept whereof is hereby acknowledged, does hereby waive, release, remiss, and relinquish any and all right to claim any lien or liens for work performed or material furnished, or any kind or class of lein whatsoever on the following described property.: ( Please provide full name and location of development and a description of the utility system constructed ) All the Potable Water and Sanitary Sewer system for Carlton Lakes Unit 3-A as depicted on the construction drawings prepared by Agnoli Barber and Brundage Engineers. By' Haleakala Construction, Inc. 5758 Taylor Road .tclOrida 34109-1856 hell, Sr., President STATE OF FLORIDA ) ) COUNTY OF COLLIER ) SS: The foregoing instrument was signed and acknowledged before me this 22 nd day of January, 2001 .... rsonally known to me and who did not take an oath. B~enda K Mercham CC 732239 7/1/96 11-3 State of Florida Department of #ea[th Office of Laboratory Services Jacksonville, Miami, Pensacola Tan~a, West PaLm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS Press hard, (5) copies FOR LAB USE ONLY SYSTEM NAME: SYSTEM I.D. NO: ADDRESS: COUNTY: COLLECTOR: SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: ._ .:; . TYPE OF SUPPLY(Circle one): Community water system~ Noncommunity water system Private well SWin~ing pool Bottled water SYSTEM PHONE #: DISTRICT: COLLECTOR PHONE #: Nontransient - noncommunity water system Limited Use system TYPE OF SAMPLE(Circle one): Compliance (Check Box) [ ] Distribution [ ] Raw Repeat Replacement Main clearance TO BE COMPLETED BY COLLECTOR OF SAMPLE COLL. NO. SAMPLE POINT (Specific Address) * Results in :his column are presumptive. P - Coliforms are present A - Coliforms are absent Cl RES'D pH Well survey Other [ ] Check here if payment made to county public health unit TO BE COMPLETED BY LAB ANALYSIS METHOD: MF MTF MMO-MUG PA *TOTAL NON COLIFORM Total coliform and fecal coliform or E. coli C - Confluent growth TNTC - Too numerous to count CONFIRM TOTAL CONFIRM FECAL E. COLI SAMPLE NUMBER :onfirmation will follow in 24-48 hours. TA - Turbid, Absence of gas or acid INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: SATISFACTORY INCOMPLETE COLLECTION INFORMATION REPEAT SAMPLES REPLACEMENT SAMPLES State of FLorida Department of Health Office of Laboratory Services Jacksonvi[[e, #iami, Pensacola Tampa, Uest PaLm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY Press hard, (5) copies SYSTEM NAME: ADDRESS: COLLECTOR: SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: TYPE OF SUPPLY(Circle one): TYPE OF SAMPLE(Circle one): SYSTEM I.D. NO: COUNTY: SYSTEM PHONE #: DISTRICT: COLLECTOR PHONE #: Community water system Noncommunity water system Nontransient - nonco~munity water system Private well Swimming pool Bottled water Limited Use system Compliance Repeat Replacement Main clearance Well survey Other (Check Box) [ ] Distribution [ ] Check hero if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE T,D BE COMPLETED BY LAB ANALYSIS METHOD: ME MTF__ MMDz,,MUG PA COLL. SAMPLE POINT C[ NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * Results in this column are presumptive. Total coliform and fecal coliform or E. coti :onfirmation will follow in 24-48 hours. P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Co[iforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REV[EWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of Ftorida Department of Hearth Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS :FOR LAB USE ONLY Press hard, (5) copies SYSTEM NAME: ADDRESS: COLLECTOR: : SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: TYPE OF SUPPLY(Circle one): TYPE OF SAMPLE(Circle one): SYSTEM I.D. NO: COUNTY: SYSTEM PHONE #: DISTRICT: COLLECTOR PHONE #: Co,unity water system Noncommunity water system Nontransient - noncommunity water system Private well Swir~ning pool Bottled water Limited Use system Compliance (Check Box) [ ] Distribution [ ] Raw Repeat Replacement Main clearance Well survey Other [ ] Check here if payment made to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED~.QY LAB _ ANALYSIS METHOD: MF MTF MMO-MUG PA COLL. SAMPLE POINT Cl NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * Results in this column are presumptive. Total coliform and fecal coliform or E_= ~oli :onfirmation will follow in 24-48 hours. p - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of Florida Department of Health Office of LaDoratocy Services Jack$~vit~e, Ni~mi, Pensacola T~ West Palm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY SYSTEM NAME: ADDRESS: COLLECTOR: Press hard, (5) copies SYSTEM I.D. NO: COUNTY: SYSTEM PHONE #: DISTRICT: SAMPLE SITE (Locality or Subdivision): COLLECTOR PHONE #: DATE AND TIME COLLECTED: TYPE OF SUPPLY(Circle one): TYPE OF SAMPLE(Circle one): Community water system Noncommunity water system Nontransient - noncommunity water system Private well Swimming pool Bottled water Limited Use system Compliance Repeat Replacement Main clearance Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB ANALYSIS METHOD: MF~ MTF MMO-MUG PA COLL. SAMPLE POINT CI NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * Results in this column are presumptive. P - Co[iforms are present A - Coliforms are absent Total coliform and fecal coliform or E. call confirmation will follow in 24-48 hours. C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REV%EWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES CERTIFICATION OF CONTRIBUTORY ASSETS PROJECT NAME LOCATION: CARLTON LAKES UNIT 3-A CARLTON LAKES SUBDMSION NAME AND ADDRESS OF OWNER: NTC DEVELOPMENT 2405 PIPER BLVD. NAPLES. FLORIDA 34110 TYPE UTILITY SYSTEM: POTABLE WATER SYSTEM DESCRIPTION AND COST OF MATERIAL. LABOR. AND SERVICES POTABLE WATER ASHWOOD LANE CONNECT TO EXISTING 6" WATER 8" PVC DR-18 WATER 8" GATE VALVE FIRE HYDRANT 3" WATER SLEEVE 4" PVC CONDUIT FITTINGS CHLORINATE & TEST ELECTRONIC LOCATORS MANCHESTER PLACE 3" WATER SLEEVE Sub Total 2 EA $1,000.00 $2,000.00 1900 LF $13.90 $26,410.00 I EA $800.00 $800.00 3 EA $2,100.00 $6,300.00 450 LF $5.70 $2,565.00 360 LF $6.00 $2,160.00 I LS $6,100.00 $6,100.00 I EA $1,000.00 $1,000.00 22 EA $20.00 $440.00 640 LF $5.70 $3,648.00 $51,423.00 (If more space is reqmred, use additional page(s). Number each page and include the name of the project. 7/1/96 11-5 CERTll*ICATION OF CONTRIBUTORY ASSETS PROJECT NAME LOCATION: CARLTON LAKES UNIT 3-A CARLTON LAKES SUBDIVISION NAME AND ADDRESS OF OWNER: NTC DEVELOPMENT 2405 PIPER BLVD. NAPLES. FLORIDA 34110 TYPE UTILITY SYSTEM: SANITARY SEWER SYSTEM DESCRIPTION AND COST OF MATERIAL, LABOR. AND SERVICES SANITARY SEWER ASHWOOD LANE CONNECT TO EXISTING 8" SEWER 8"PVC SDR-26 SEWER 0-6'CUT 8" PVC SDR-26 SEWER 6-8' CU']' 4'DIA MANHOLE 0-6'CUT 4'DIA MANHOLE 6-8'CUT 6" PVC LATERAL 6" SINGLE CLEAN-OUT 6" DOUBLE CLEAN-OUT T.V. VIDEO SEWER MANCHESTER PLACE CONNECT TO EXISTING 8" SEWER 8" PVC SDR-26 SEWER 0-6' CUT 4'DIA MANHOLE 0-6'CUT 6" PVC LATERAL 6" SINGLE CLEAN-OUT 6" DOUBLE CLEAN-OUT T.V. VIDEO SEWER Sub Total 2 EA $1,500.00 $3,000.00 1219 LF $22.00 $26,818.00 310 LF $26.00 $8,060.00 6 EA $1,400.00 $8,400.00 1 EA $1,750.00 $1,750.00 740 LF $10.50 $7,770.00 2 EA $200.00 $400.00 19 EA $225.00 $4,275.00 1 EA $2,050.00 $2,050.00 1 EA $1,500.00 $1,500.00 546 LF $22.00 $12,012.00 3 EA $1,450.00 $4,350.00 585 LF $10.50 $6,142.50 2 EA $200.00 $400.00 i 3 EA $225.00 $2,925.00 i EA $1,300.00 $1,300.00 $91,152.50 (If more space is required, use additional page(s). Number each page and include the name of the project. 7/1/96 I1 -5 mmmmF~ lb~U~l mmmmm&n mmmmmm mmmmm).~AELBER& mmmlmmk'l-~ iliiIi1~ ..... lmmmmmf. J_;~U~U~u~,XN~. January29,2001 Collier County Board of Commissioners 3301 Tamiami Trail East Naples, FL 34112 Re: Carlton Lakes Unit 3A Honorable Commissioners: The purpose of this letter is to certify that to the best of my knowledge, information and belief and in accordance with commonly accepted procedures consistent with applicable standards of practice, the water and sewer facilities to be dedicated at the above-referenced project have been constructed within Tract R of the plat of Carlton Lakes Unit No. 3A, as recorded in Plat Book 35, pages 16 - 18 of the Public Records of Collier County, Florida. This is not a guaranty or warranty, either expressed or implied. Sincerely, James A. Carr, P.E. JAC/jam 1-765j l.,2erl WARRANTY The undersigned parties do hereby warrant and/or guaranty all work executed by the contractor on the water and/or sewer ~stems of (Developer) CARLTON LAKES UNIT 3-A to be free from defects in material and workmanship for a period of at least one ( I ) year from the date of acceptance by the Collier County Board of County Commissioners. The undersigned parties further agree that they will, at their own expense, repair and replace all such defective work and all other work damaged by said defective work under this Warranty - Guaranty. It is furthermore understood that the consideration for the giving of this Warranty and/or Guaranty is the requirement by the General Conditions and Specifications under which the contract was let that such Warranty and/or Guaranty would be given. Haleakala Construction, Inc. STATE OF FLORIDA ) ) COUNTY OF COLLIER ) SS: The foregoing instrument was signed and acknowledged before me this _22 nd day of January, 2001 by Timothy C. Mitchell, St, who is personally known to me and who did not take an oath. CC 732239 7/1/96 11-2 Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number 252056 Date Post Date 03113/2001 12:26:17 PM 03/13/2001 Payment Slip Nbr UT 82861 HALEAKALA CONSTRUCTION, INC. HIGHWOOD PARK LN/CARLTON LAKES UNIT 3 A Payor · HALEAKALA CONSTRUCTION Fee Code 42CYIN Fee Information Description COUNTY INVOICES GL Account 40800000011510000000 Total Amount $277.88 $277.88 Waived Payments Payment Code Account/Check Number Amount CHECK 027892 $277.88 Memo: DOR1380, W/O ~034204/032603, + BACT Total Cash / $0.00 Total Non-Cash ~ $277.88 Total Paid L $277.88 Cashier/location: CROMEENES_A / 3 User: AVILES_L Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:09/13/2001 11:58:41 AM May-Il-01 ~:~.PM~, Inc. of Naples 435-9082 P.02 FIRE PREVENTION BUREAU 1780 Irnmokalee Road · Naples, Florida 34110 (941 ) 597-9227 · Fax (941) 597-3522 May 11, 2001 PMS 2335 9th St. N., Suite/I.408 Naples, FL 34103 RE: Hydrant Flow for Carlton Lakes- 6254, 6219, 6171 Ashwood Lane Dear Sir, The North Naples Fire Control and Rescue District has conducted a flow test at the above location. This also will serve as an invoice of $3500 to cover the cost of the test Please make your check payable to North Naples Fire Department, and you must reference the name of the job on the check. Following are the results of the flow test: Static: 70 Resid: 38 Flow: 787 Pitot: 22 If you have any questions, please do not hesitate to give me a call at 597-9227. SinTrely, Karl K. Reynolds, Fire Marshal Norlh Naples Fire Prevention Bureau KKR/dw I"l'~)li2hhi(~llJ.] ¢ll~iltc',.'{"-,, 1',]31111¢1"-,. '~tl{", CV(>I'h ~-~ SDP-2001 -A R-683 JaSmine Pointe Project # · 2001030064 Date. '1/17/01 GRAVITY SEWER INFILTRATION TEST REPORT PROJECT Carlton Lakes 3-A Manchester Place PN 6696-3A TN X002 WITNESSED BY Jim Bailey PROCEDURE: TIME DATE MEASUREMENT 10:30 a.m. 3/27/01 N/A MEASUREMENT 10:30 a.m. 3/28/01 N/A INFILTRATION Zero GPD VERTICAL DISTANCE LID TO WATER Line was plugged at existing SMH. ALLOWABLE LEAKAGE: SEWER SIZE 8 INCHES, D TOTAL LENGTH 555 FT/5280 = 0.10 MI, L ALLOWABLE LEAKAGE 50 GPD/MI/INCH DIA AL = (50XDXL) = 40 GPD PASSED Yes APR 0 2 2001 l.cc'(;OtllltV: 1(>23 {Icu,h" $~. ,~,~lil~' II)1 t',,~ ,\l\,.'t".,1 h,tid.~ ?,.:;'>(> <141 ~S4 117S t:,kX: ',94l)334 1175 GRAVITY SEWER INFILTRATION TEST REPORT PROJECT Carlton Lakes 3-A Ashwood Lane PN 6696-3A TN X002 WITNESSED BY Jim Bailey PROCEDURE: TIME DATE MEASUREMENT 10:45 a.m. 3/27/01 N/A MEASUREMENT 10:45 a.m. 3/28/01 N/A INFILTRATION Zero GPD VERTICAL DISTANCE LID TO WATER Line was plugged at existing SMH. ALLOWABLE LEAKAGE: SEWER SIZE 8 INCHES, D TOTAL LENGTH 740 FT/5280 = 0.14 MI, L ALLOWABLE LEAKAGE 50 GPD/MI/INCH DIA AL = (50XDXL) = 56 GPD PASSED Yes APR 0 2 200'i ,,,m.,mmy,,~ lmmmm~/.~ ,~ ~,~ T I IIIII1~ T~ o Illlllk'l'~ mmmmmml.J..Jt~u IN LJJ¥,~J~, inc. SDP'2001-AR.683 Jasmine Poir~te Project ~7 · 2001030064 Date · 4/17/01 GRAVITY SEWER INFILTRATION TEST REPORT PROJECT Carlton Lakes 3-A Ashwood Lane PN 6696-3A TN X002 WITNESSED BY Jim Bailey PROCEDURE: TIME DATE MEASUREMENT 10:50 a.m. 3/27/01 N/A MEASUREMENT 10: 50 a.m. 3/28/01 N/A INFILTRATION Zero GPD VERTICAL DISTANCE LID TO WATER ALLOWABLE LEAKAGE: SEWER SIZE 8 INCHES, D TOTAL LENGTH 800 FT/5280 = 0.15 MI, L ALLOWABLE LEAKAGE 50 GPD/MI/INCH DIA AL = (50XDXL) = 60 GPD PASSED Yes James A. Cart, P.E.#51318 APR 0 2 2001 Main ¢)fticc: 740{! ['..l~i..!li'll'aiIN,~4.ilc20(L N:?Ics. t'!,,li~i;3tl<~l c941 597 3111 FAX: 941)566-2203 ?~5 P02 $~N 25 ~01 16:5~ 9~19976645.~INTS&COATINGS "Tke Rehabi~itadon! To ~om ~t M~'¥ Concertt: supplied tO,~n the ZO0. 3n ac~ptable bituminotss or se:tier. C;ari A. Laquidar~ p~sident / COLLIER COUNTY UTILITIES WASTEWATER DEPARTMENT PROJECT VIDEO REVIEW DATE OF REVIEW: PROJECT NAME: ENGINEER OF RECORD: 3/9/2001 Carlton Lakes Tract 3A County (North) CONSTRUCTION CONTRACTOR: Haleakala VIDEO CONTRACTOR: Sewer Viewer COMMENTS: Lines and services acceptable RECOMMENDATIONS: ACCEPTABLE: REVIEW NUMBERED COMMENTS IN ONE YEAR: NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE): OTHER RECOMMENDATIONS: Signature: David Fitts COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION April 2, 2001 PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Mr. Jim Carr Agnoli, Barber & Brundage, Inc. 7400 Tamiami Trail N. Suite 200 Naples, Florida 34108 941-597-3111 RE: Carlton Lakes 3-A, Water & Sewer Dear Mr. Carr: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on April 2, 2001. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418. Sincerely' ,~z~// Randy Casey Engineering Inspector cc: Lisa Taylor, Engineering Technician, Public Works Joe Cheatham, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Diane Deoss, D.O.R. Billing Supervisor Don Nobles, Engineering Inspections Supervisor Randy Casey, Engineering Inspector Shirley Nix, Engineering Tech. II, Engineering Review Section File PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us