Loading...
Links at the StrandDATE: TO: FROM: RE: MEMORANDUM October 25, 2000 Maureen Kenyon, Supervisor, Clerk to Board Shirley Nix, Engineering Technician II ~ Project Plan Review The Links @ The Strand Water and/or Sewer Facilities Acceptance On ' | -~'O'%./,-; , 200 The Board of County Commissioners granted final acceptance of The water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded documents, in order: 1. Utilities Facilities Subordination, Consent and Joinder 2. Bill of Sale 3. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. 10. 11. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Copy of Standby Letter of Credit # 78530105 Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities DER Placement-in-Service letter for sewer facilities 12. Contractor's Final Release of Lien Memorandum to Maureen Kenyon, Supervisor, Clerk to Board October 25, 2000 Page Two 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. Lab results on bacteriological test for water lines Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing Certification of the inflow/infiltration test for the sewer lines by Engineer of Record Coating certification of man holes, wet wells and dry well from manufacturer Copy of video tape test report Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations If you have any questions, please call and advise accordingly. attachments doc:2094-2 Dwight E. Brock Clerk County of Collier CLERK OF THE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301TAMIAMI TRAIL EAST P.O. BOX 4413044 NAPLES, FLORIDA 34101-3044 ORIGINAL BRANCH OFFICES: GOLDEN GATE 4839 GOLDEN GATE PARKWAY GREENTREE SHOPPING CENTER 2386 IMMOKALEE ROAD IMMOKALEE 106 S. FIRST STREET MARCO ISLAND 1040 WINTERBERRY DRIVE EVERGLADES CITY 207 BROADWAY AVENUE OFFICIAL RECEIPT When Validated BY: TONI B DEPUTY CLERK RECEIPT: NAME : PAYOR: REFNC: 330'1885 ENGINEERING REVIEW/S NIX BCC #113-138312-63-6490 LP: 3 DOCUMENTS DOC TYP FILE ID BOOK PAGE SUBORD 2706359 2736 2492 B SALE 2706360 2736 2495 DEED 2706361 2736 2498 DESCRIPTION RECORDING OF LEGAL INSTRUMENT P.R.M.T.F. RECORDING FEE INDEXING DOCUMENTARY STAMPS - 70 DOCUMENTARY STAMPS - 35 INTANGIBLE TAX SALES COPIES MISCELLANEOUS FEES INTANGIBLE PENALTY INTANGIBLE INTEREST AMOUNT 39.00 6.00 .70 DEPT: RECORDING TOTAL DUE: 45.70 Page 01 of 01 Return to: Board of Collier County Commissioners This instrument prepared by: Leo J. Salvatori, Esq. Quarles & Brady LLP 4501 Tamiami Trail North Suite 300 Naples, Florida 34103 2706359 OR: 2736 PG: 2492 IICORDID tn OFFZCXAL IB(:OIDS o~ ~LLZBI COUP, 10/27/2000 at 08:26~ D~IG~ I. BROCK, ~C FIB 15.00 le~n: SHIRLIY NII/B~IIBIR~JG HOUISHOB UTILITY FACILITIES SUBORDINATION, CONSENT AND JOINDER (The Strand - Links at The Strand) THIS SUBORDINATION, CONSENT AND JOINDER given this /Cf day of C~?/,'I~ J/~ ,~ 2000, by and between CREDIT,SUISSE FIRST BOSTON MORTGAGE PITAL, LLC, (hereinafter referred to as "Mortgagee-), in favor of the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER- SEWER DISTRICT, its successors and assigns (hereinafter referred to as "County"). Mortgagee is used as singular or plural, as the context requires. WITNESSETH: WHEREAS, Mortgagee is the owner and holder of the following, which hereafter shall collectively be referred to herein as the "Mortgage": A certain Mortgage from Pelican Strand, Ltd. now held by Credit Suisse First Boston Mortgage Capital, LLC, a Delaware limited liability company, recorded July 6, 1998, in Official Records Book 2437, Page 1791, of the Public Records of Collier County, Florida, as modified. A certain Assignment of Leases and Rents from Pelican Strand, Ltd. in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded in Official Records Book 2437, Page 1834, of the Public Records of Collier County, Florida. A certain UCC-1 Financing Statement from Pelican Strand, Ltd. in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded July 6, 1998 in Official Records Book 2437, Page 1848, of the Public Records of Collier County, Florida. WHEREAS, County has requested and received from the fee simple owner of the Encumbered Property non-exclusive easements for the installation and maintenance of water and sewer utility facilities over and across a portion of the encumbered premises legally described in Exhibit "A" attached hereto and incorporated herein by virtue of this reference, which premises are hereinafter referred to as the "Easement Property". QBNAP\226717.1 OR: 2736 PG: 2493 WHEREAS, County has requested that Mortgagee consent to, join in and subordinate its Mortgage to the interest that County has in the Easement Property to which request Mortgagee has agreed. NOW, THEREFORE, in consideration of TEN ($10.00) DOLLARS and other good and valuable consideration, the receipt of which is hereby acknowledged, the Mortgagee does hereby consent to, join in and subordinate the lien of its Mortgage to the grant of that certain easement described herein over, under, and across the Easement Property and any interest of the County in any water and sewer utility facilities located therein or affixed thereto. Except as subordinated to the easement described herein over, under, and across the Easement Property or any water and sewer utility facilities located therein or affixed thereto, said Mortgage shall remain otherwise in full force and effect. IN WITNESS WHEREOF, the Mortgagee has caused these presents to be executed the date and year first above written. Signed, sealed and delivered in the ~ Witness #1 {Print name below) Witness #2 (Print name below) MORTGAGEE: CREDIT SUISSE FIRST BOSTON MORTGAGE CAPITAL, LLC, a Delaware lim, Lted liability company Title: (J'~ ~,,~i6~'~~ STATE OF NEW YORK o. _~ The foregoing instrument was sworn to and subscribed before me this i'0 da of Cred~t~Suisse First Boston Mortgage Capital LLC, Who is personally known to me, or who has produced , as identifica~ My Commission Expires: (Notary Seal) ALICE RUSSELL Not .... ...... ary I~UDIIC Notary Public State et New Yetis, . _ No. 01'RU5081837 tpnn~ name below) Commission No. Oua fled in Kings County Commission Expires July 14, 2001 QBNAP\226717.1 2 *** OR: 2736 PG: 2494 *** Exhibit "A" Tract 12, Links at The Strand, according to the plat thereof recorded in Plat Book 34, Pages 41 and 42, Public Records of Collier County, Florida. Return to: Board of Collier County Commissioners This instrument prepared by: Leo J. Salvatori, Esq. Quarles & Brady LLP 4501 Tamiami Trail North Suite 300 Naples, Florida 34103 2706360 OR: 2736 PG: 249§ RICORDBD ta Ot*~ICIAL itBCORDS of COLLIIII CouFrY, ~L 10/27/2000 at: 08:36AS DIfXGHY B. BROCK, CLllt[ nc FIB 15.00 Retn: SHXRLI! ilXZ/BIIGIHllIIIIG HVlllf HOIiSBSHO! Mt[VI Iff 5586 BILL OF SALE (The Strand - Links at The Strand) THIS BILL OF SALE evidencing the sale and con~veyance, of the water and sewer utility facilities described herein is made this ~day of ~/I/~f~" , 2000, by THE STRAND, LTD., formally known as PELICAN STRAI~IDt, LTD., a Florida limited partnership (hereinafter referred to as "Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns (hereinafter referred to as "Buyer"). WlTNESSETH: That said Seller, for and in consideration of the sum of TEN ($10.00) DOLLARS and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set-over and delivered, and by these presents does grant, bargain, sell, transfer, set-over and deliver unto Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water facilities and sewer facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida to wit: (See Exhibit "A" attached hereto and incorporated by reference herein.) The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. QBNAP\226700.1 OR: 2736 PG: 2496 IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. Signed, sealed and delivered inpat~ presenc..e:,. Witness # 1 (Print name/address below) witnesS% 2 ~ {¢rint name/addross THE STRAND, LTD., a Florida limited partnership (Corporate Seal) THE STRAND DEVELOPMENT CORPORATION OF NAPLES, a Florida corporation,By: ///as Gc-~~al~e~r~% Ro'13ert Paul Hardy, as Vice Presid/~nt ~; 2St;~:adnd Court / Suite One Naples, FL 34110 STATE OF FLORIDA COUNTY OF COLLIER /,'"",~ The foregoing instrument was sworn to and acknowledged before me this-7 ~-~ day of L..Z-~,-~c~.~_. , 2000, by Robert Paul Hardy, as Vice President of THE STRAND DEVELOPMENT CORPORATION OF NAPLES, a Florida corporation, as General of THE STRAND, LTD., a Florida limited partnership, who is personally known to me. My Commission Expires: ~1 ,,,~-~F.~: BETH A. WEBER ~1~?' ~f "~. MY COMMISSION ~ CC 812680 ~ ~1~:~.[~ EXPIRES'. Februa~ 28 2003 I[ .~. .~ , ii,:.,;~;.... BondedThmNota~PublicUnd~ers II NOTARY PUBLIC (SEAL) (~P~ name b.~:)w), · .~,.,, f .;1, Notary Public '~"~1~ Serial # (if any) QBNAP\226700.1 2 *** OR: 2736 PG: 2497 *** Exhibit "A" Tract 12, Links at The Strand, according to the plat thereof recorded in Plat Book 34, Pages 41 and 42, Public Records of Collier County, Florida. Tth. e UtiLity Facilities Public Works. Return to: Board of Collier County Commissioners This instrument prepared by: Leo J. Salvatori, Esq. Quarles & Brady LLP 4501 Tamiami Trail North Suite 300 Naples, Florida 34103 2706361 OR: 2736 PG: 2498 llCOIDID in OFFICIAL RiCOilDS of COLLIBII COlJl~, FL 1o/27/2ooo at 08:36~ D~I~ B. SROCl, CLSli SHIRLJY NII/I#GINBIRIIlG RBVIBIf HORSBSHOB DRIVB DOC-.70 15.00 .70 UTILITY FACILITIES WARRANTY DEED (The Strand - Links at the Strand) THIS INDENTURE made this ___~Nday of ~ ~1/,tt ,~2000,between THE sTRAND,, LTD., formally known as PELICAN STRAND, LTD., a I~lorida limited partnership, (hereinafter "GRANTOR"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY, AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "GRANTEE"). WITNESSETH: That said GRANTOR, for and in consideration of the sum of TEN ($10.00) DOLLARS and other good and valuable consideration to said GRANTOR, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said GRANTEE, and GRANTEE'S heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: (See Exhibit "A" attached hereto and incorporated by reference herein.) and said GRANTOR does hereby fully warrant the title to said facilities, and will defend same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A". GRANTOR and GRANTEE are used for singular or plural, as context requires. QBNAP\226710.1 OR: 2736 PG: 2499 IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. Signed, sealed and delivered i?.~:t[ presenc, c.c.c~.~ Witness ~ 1 (Print name/address below) Witne~ ~ 2~ (Print name/address below) THE STRAND, LTD., a Florida limited partnership (Corporate Seal) THE STRAND DEVELOPMENT CORPORATION OF NAPLES, a Florida corporation, as General Partr~r By:ThesuiteNaples,RObert5692Stran~oneStrandPa~ardY'FL 341Courtl '0 as Vice President STATE OF FLORIDA COUNTY OF COLLIER .,q The foregoing instrument was sworn to and acknowledged before me this'-~/¢~;'~ day o_f_.._~. ~:)~-~ , 2000, by Robert Paul Hardy, as Vice President of THE STRAND u~-VELOPMENT CORPORATION OF NAPLES, a Florida corporation, as General of THE STRAND, LTD., a Florida limited partnership, who is personally known to me. My Commission Expires: ~Jl .t~,'~,~J~;';r', BETH A WEBER -'k~" "~;: ' llt:~] EXPIRES: Februaff 28, 2003 ~ ";JY~"~t~,,;~ gor~d~d Thru Neta~ Public NOTARY PUBLIC (SEAL) (P~ name/J~elow) Notary Public -' ~:~ ~, ~e~%-- SerialS(if any) ~tZ/~ QBNAP\226710.1 *** OR: 2736 PG: 2500 Exhibit "A" Tract 12, Links at The Strand, according to the plat thereof recorded in Plat Book 34, Pages 41 and 42, Public Records of Collier County, Florida. The Utility Facilities csn be found ~ p'~ans ;ocated i~ f;~es in Public Works. OWNER'S AFFIDAVIT (The Strand - Links at The Strand) STATE OF FLORIDA COUNTY OF COLLIER On this _~day of J/~ I~J ~, 2000, before me personally appeared Robert Paul Hardy, as Vice l~esident of THE STRAND DEVELOPMENT CORPORATION OF NAPLES, a Florida corporation, as General Partner of THE STRAND, LTD., a Florida corporation, owner of property to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of water and sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to the Owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant further says that utility facilities described herein are not included in, encumbered by, or subject to any real property mortgage, chattel mortgage, security agreement, Uniform Commercial Code financing statement, or any other encumbrance except the following: A certain Mortgage from Pelican Strand, Ltd. now held by Credit Suisse First Boston Mortgage Capital, LLC, a Delaware limited liability company, recorded July 6, 1998, in Official Records Book 2437, Page 1791, of the Public Records of Collier County, Florida, as modified. w A certain Assignment of Leases and Rents from Pelican Strand, Ltd. in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded in Official Records Book 2437, Page 1834, of the Public Records of Collier County, Florida. A certain UCC-1 Financing Statement from Pelican Strand, Ltd. in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded July 6, 1998 in Official Records Book 2437, Page 1848, of the Public Records of Collier County, Florida. Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. QBNAP\226727.1 The utility facilities referred to herein are located within the real property described in the attached Exhibit "A". THE STRAND, LTD,, a Florida limited partnership, (Corporate Seal) THE STRAND DEVELOPMENT CORPORATION OF NAPLES, a Florida corporation, as Genii Partner /? J / By: Rol~'e t aul Hardy, as Vice President STATE OF FLORIDA COUNTY OF COLLIER /~ The foregoing instrument was sworn to and subscribed before me this'~L~ day of ~O~-~..,-_...~L~ , 2000, by Robert Paul Hardy, as Vice President of THE STRAND DEVEL~)PMENT CORPORATION OF NAPLES, a Florida corporation, as General Partner of THE STRAND, LTD., a Florida limited partnership, who is personally known to me. NOTARY PUBLIC (SEAL) My Commission Expires: (Print name below) Notary Public Serial # (if any) Cd gl ,,)_ (,,~ ~ QBNAP\226727.1 2 ATTORNEY'S AFFIDAVIT (The Strand - Links at The Strand) STATE OF FLORIDA COUNTY OF COLLIER BEFORE ME, the undersigned authority, personally on this 2p ~ day of appeared LEO J. SALVATORI, who to me is well known, and having been sworn oath, desposes and states: a~n d~u'nde r My name is LEO J. SALVATORI. I am over the age of twenty-one (21) years, and otherwise suijuris, and have personal knowledge of the facts contained herein. I am a licensed attorney, Florida Bar //303100, authorized to practice in the State of Florida. My business address is: 4501 North Tamiami Trail, //300, Naples, Florida 34103. My business telephone number is: (941) 262-5959. My business mailing address is: 4501 North Tamiami Trail, Suite 300, Naples, Florida 34103. o This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, to accept water and sewer utility facilities located upon the real property described in the attached Exhibit "A", which is incorporated herein by this reference, said land being located in Collier County, Florida. The Affiant has examined record title information to the real property referenced in this affidavit through June 26, 2000, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. The record owner of some of the real property described herein is THE STRAND, LTD., a Florida limited partnership, formerly known as PELICAN STRAND, LTD. (hereinafter "Owner"). The Owner acquired record title to the subject real property by instruments recorded at Official Records Book 2117, Pages 654 and 657, of the Public Records of Collier County, Florida, attached hereto as Exhibit The record owner of the balance of the real property is THE LINKS AT THE STRAND DEVELOPMENT CORPORATION, a Florida corporation ("The Links"). Copies of recorded deeds to The Links are attached hereto as Exhibit "B-1 ." The Affiant has examined the partnership information for THE STRAND, LTD., a Florida limited partnership, and is of the opinion that the same is current and active within the State of Florida, and is currently authorized to do business in the State of Florida. The sole general partner of THE STRAND, LTD. is The Strand Development Corporation of Naples, a Florida corporation, formerly known as PELICAN STRAND DEVELOPMENT CORPORATION. The undersigned has reviewed corporate information for said corporation, and is of the opinion that it is duly organized under the laws of the State of Florida, and is authorized to execute documents on behalf of the partnership. QBNAP\224635.1 10. 11. 12. 13. The Vice President of The Strand Development Corporation of Naples is Robert Paul Hardy, who possesses due power and authority to execute documents on behalf of said corporation. In said capacity, Robert Paul Hardy also has the power and authority to execute documents on behalf of The Strand Development Corporation of Naples, in its capacity as general partner for THE STRAND, LTD. The undersigned reviewed corporate information for THE LINKS AT THE STRAND DEVELOPMENT CORPORATION, and is of the opinion that it is duly organized under the laws of the State of Florida. The President of The Links at the Strand Development Corporation is John Globetti, who possesses due power and authority to execute documents on behalf of said corporation. The subject real property is encumbered of record by the following: a) A certain Mortgage from The Strand, Ltd., f/k/a Pelican Strand, Ltd., now held by Credit Suisse First Boston Mortgage Capital, LLC, a Delaware limited liability company, recorded July 6, 1998, in Official Records Book 2437, Page 1791, of the Public Records of Collier County, Florida, as modified; b) A certain Assignment of Leases and Rents from The Strand, Ltd., f/k/a Pelican Strand, Ltd., in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded in Official Records Book 2437, Page 1834, of the Public Records of Collier County, Florida; c) A certain UCC-1 Financing Statement from The Strand, Ltd., f/k/a Pelican Strand, Ltd., in favor of Credit Suisse First Boston Mortgage Capital, LLC, recorded July 6, 1998 in Official Records Book 2437, Page 1848, of the Public Records of Collier County, Florida. d) A certain Mortgage from The Links at the Strand Development Corporation in favor of AmSouth Bank, recorded October 9, 1996 in Official Records Book 2239, Page 662, of the Public Records of Collier County, Florida. Said mortgage does not encumber any sewer facilities or water facilities located therein. Affiant best of Title is further states that the informati, p~.contained in this Affidavit is, to the his knowledge, true, correct .end current as of the date this Affidavit of given, except as otherwiseASrovided herein. .' / // i /,y'/ (/ ~'~. $~lvat0h, Esquire --~l~i~cl~ Bar Nur~ber: 303100 QBNAP\224635.1 STATE OF FLORIDA COUNTY OF COLLIER/'~ SUBSCRIBED AND SWORN to before me this ~ ~ day of Ju',y,-2000, by Leo J. Salvatori, who is personally known to me. : Notary Public (SEAL) My Commission Expires: Prepared by: Leo J. Salvatori, Esquire QUARLES & BRADY LLP 4501 North Tamiami Trail, #300 Naples, Florida 34103 fi Nancy C. Jarvi ~ Notary Publi~;. State of Florida ~]]]L_MY Comm. E~r~ires Sep_ .24, 2000 Bonded Thru: Off'' ::~ N,~t~ary ,S. ervica QBNAP\224635.1 Exhibit "A" Tract 12, Links at The Strand, according to the plat thereof recorded in Plat Book 34, Pages 41 and 42, Public Records of Collier County, Florida. EXHIBI' This in.,;tmment prepared by :md after recording return Leo J. S;tlvatori, Esq. Quartes& Brady, LLP 4501 Tamiama Trail Nor'ill. Suite 300 Naples. Florida 3a103 2639967 OR: 2679 PG: 0809 ~CORO~ l~ OHICIA~ R~COR~ of ¢OLSI~R CO~?~, ?~ ¢0~S R]C ~] 10.50 IlOlIIWG 1.00 DOC-.70 553,00 Retn: 3838 T~I~I TR ! t402 SPECIAL WARRANTY D~S [,r. 34103 This Indenture, made this,--, 4-*- ~ i' '-day ofi~,[ 6Lc..~-' , 2O00, between TIlE STRAND. LTD., f/~a PELICAN ~f~ND, LTD., a FIorida'J limited partnership, G~NTOR, THE LINKS AT THE STRAND DEVELOPMENT CORPO~TION, a Florida co~oradon, whose tax identification number is , and whose post office address is 5675 Straml Court, Naples, FL 34110, G~NTEE. Wimesseth that said Grantor, for and in consideration of the sum of TEN DOLLARS, and other good and valuable consideration, to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknow;edgcd, have granted, bargained and sold to the said Grantee and Grantees heirs and assigns forever, the foUowing described land, situate, lying and being in Collier County, Florida. Lot 6. Tract 12, Links at the Strand, according to the plat thereof recorded in Plat Book 34, Pages 4.1 and 42, of the Public Records of Collier County, Florida. Subject to oil, gas and mineral rights of record; and real estate taxes for the year 2000, and all subsequent years, being a portion of the property bearing Property Identification Number 66679'717108. Further subject to the Declaration of Covenants, Conditions, Restrictions and Easements for Pelican Strand, recorded in Official Record Book 2292, Page 1637, of the Public Records of Collier County, Florida: together with the Articles of Incorporation, By-Laws and Rules and Regulations of Pelican Strand Master Property Owner's Association, Inc., as set forth therein. Further subject to the terms and provisions of the Agreement Establishing Easements, Maintenance Responsibilities, and Sharings of Costs recorded in Official Record Book 2292, Page 1802; and the Water Management System Shared Cost and Maintenance Agreement recorded in Official Record Book 2292, Page 18 ti, o~ the Public Records o~ Collier County, Florida. as the santo may be amended from time to time. /Further subject to the Declaration of Neighborhood Covenants recorded in Official Record Book 2631. Page 3251, of the Public Records of Collier County, Florida. This Deed is an absolute conveyance and said Grantor will warrant and defend the property hereby conveyed against the lawful claims and demands of al! Fcrsons clz, iming by, through, or under said Grantor, but against none other. RE. cORD & RETURN TO: MC, RRiSON & cONRO¥ 3838 TAMIAMI TRAIL NORTH, ST5 402, NAPL(iS, Fi. 34103 OR: 2679 PG: 0810 *** In Witness Whereof, the Grantor has hereunto set Grantors hand and seal the day and year first above written. Signed, sealed and delivered in our presence: BY: THE STRAND, LTD., f/k/a PELICAN STIL-\ND, LTD., a Florida limited parmership THE STRAND DEVELOPMENT CORPORATION OF NAPLES, f/k/a PELICAN STRAND DEVELOPMENT CORPORATION, a Florida corporation, as Lts's~e ge, neral,,.part~ner) ROBER]4 PAUL HARDY, as Vice-Pre~ident 564.5 Strand Boulevard Naples, FL 34110 STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was acknowledged before me this /~TP-'/~day of ~/},"~ ~t , 2000, by ROBERT PAUL HARDY, as Vice-President of THE STRAND DE,,/ELCJPMENT CORPORATION OF NAPLES, ffk]a PELICAN STRAND DEVELOPMENT CORPORATION, a Florida corporation, ~S sole general parmer of THE STRAND, LTD., f/kIa PELICAN STRAND, LTD., a F{orida linfiteds!a, rmership, who is personally known to me. My Commission Expires: ~_.TA~Y PUBLIC, , , (SEAl.) ......... ' ~,4.,,~--, tq. [X~:'.L~'~ . ~'. ,'-"~".:,} :.~y CO,V, UISS;ON * Cc 8'~,~r~o : ...... ~ ' - ..... (Print name/address) COLLIER COUNTY GOVERNMENT C_OMMUNITY DEVF~LOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 October 16, 2000 Ms. Cindy Yanosik, P.E. Community Engineering Services, Inc. 9200 Bonita Beach Road Bonita Springs, FL. 34134 Re: Links at the Strand Dear Ms. Yanosik: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very t~uly yours,/ John R. Hou~d~worth Senior Engineer cc: shirley Nix PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION October 17, 2000 PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Cynthia G. Yanosik, P.E. Community Engineering Services 9200 Bonita Beach Road Bonita Springs, FL 34134 Re: The Links ~ The Strand Dear Ms. Yanosik: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, /' / Shirley Nix'-~ Engineering Technician II CC: Joe Cheatham, Wastewater Director Paul Mattausch, Water Director Lisa Taylor, Public Works John Houldsworth, Engineering Review PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us AmSouth Bank Post Office Box 11007 Birmingham, Alabama 35288 (800) 284-4100 Telex: 6823023 S.W.I.F.T.: AMSBUS44 USA International Division DATE: JULY 21, 2000 RE: IRREVOCABLE STANDBY LETTER OF CREDIT NO.: 78530105 BENEFICIARY: THE BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY, FLORIDA GOVERNMENT COMPLEX NAPLES, FLORIDA 34103 APPLICANT: A.R.B.C. CORPORATION 5675 STRAND COURT, NAPLES, FL 34110 AT THE REQUEST OF AND FOR THE ACCOUNT OF A.R.B.C. CORPORATION (THE "APPLICANT"), WE HEREBY ESTABLISH THIS IRREVOCABLE LETTER OF CREDIT IN THE AMOUNT OF $10,707.03 (TEN THOUSAND SEVEN HUNDRED SEVEN AND 03/100 U.S. DOLLARS), IN FAVOR OF THE BOARD OF COUNTY COMMISSIONERS, COLLIER COUNTY, FLORIDA 33962 ("BENEFICIARY"). IN ACCORDANCE WITH THE TERMS AND CONDITIONS HEREINAFTER SET FORTH. 1. THIS LETTER OF CREDIT AUTOMATICALLY EXPIRES AT THE CLOSE OF BUSINESS ON THE EARLIER OF: (A). JULY 20,2001 (B) THIS CREDIT SHALL BE VALID UNTIL JULY 20, 2001, AND IS A CONDITION OF THIS CREDIT THAT IT SHALL BE DEEMED AUTOMATICALLY EXTEND WITHOUT AMENDMENT FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE PRESENT OR ANY FUTURE EXPIRATION DATE UNLESS AT LEAST SIXTY (60) DAYS PRIOR TO ANY SUCH EXPIRATION DATE WE SHALL NOTIFY YOU IN WRITING BY REGISTERED MAIL, RETURN RECEIPT REQUESTED, OR COURIER SERVICE, THAT AmSouth Bank Post Office Box 11007 Birmingham, Alabama 35288 (800) 284-4100 Telex: 6823023 S.W.I.F.T.: AMSBUS44 USA International Division PAGE 2 IRREVOCABLE STANDBY LETTER OF CREDIT NO.: 78530105 WE ELECT NOT TO EXTEND THIS LETTER OF CREDIT FOR ANY SUCH ADDITIONAL PERIOD. 2. MAXIMUM CREDIT. THE MAXIMUM AGGREGATE CREDIT AVAILABLE UNDER THIS LETTER OF CREDIT SHALL BE USD 10,707.03 (THE "MAXIMUM CREDIT"). 3. DRAWING. THE DRAWING IN RESPECT OF PAYMENT HEREUNDER HONORED BY US SHALL NOT EXCEED THE MAXIMUM CREDIT. 4. DOCUMENT TO BE PRESENTED. FUNDS UNDER THIS LETTER OF CREDIT ARE AVAILABLE TO YOU AGAINST: (A). YOUR SIGHT DRAFT STATING ON ITS FACE "DRAWN UNDER AMSOUTH BANK IRREVOCABLE LETTER OF CREDIT NUMBER 79530105", AND (B). A CERTIFICATE SIGNED BY THE COUNTY MANAGER, CERTIFYING.: "A.R.B.C. CORPORATION HAS FAILED TO CONSTRUCT AND/OR MAINTAIN THE UTILITIES/INTRASTRUCTURE IMPROVEMENTS AS SHOWN ON THE PLANS FOR FOR THE LINKS OF THE STRAND OR A FINAL INSPECTION SATISFACTORY TO COLLIER COUNTY, PURSUANT TO COLLIER COUNTY ORDiNANCE NO. 97-17, AS AMENDED, HAS NOT BEEN PERFORMED PRIOR TO THE DATE OF EXPIRY, AND SATISFACTORY ALTERNATIVE PERFORMANCE SECURITY HAS NOT BEEN PROVIDED TO AND FORMALLY ACCEPTED BY THE BENEFICIARY". 5. METHOD AND NOTICE OF PRESENTMENT. THE DOCUMENTS REQUIRED BY PARAGRAPH 4 FOR DEMAND FOR PAYMENT UNDER THIS LETTER OF CREDIT (THE "DEMAND FOR PAYMENT") MAY BE DELIVERED TO US IN PERSON, BY MAIL OR BY AN EXPRESS DELIVERY SERVICE. DEMAND FOR PAYMENT SHALL BE PRESENTED iN OUR OFFICE, AmSouth Bank Post Office Box 11007 Birmingham, Alabama 35288 USA (800) 284-4100 Telex: 6823023 S.W.I.F.T.: AMSBUS44 International Division PAGE NO.: 3 IRREVOCABLE STANDBY LETTER OF CREDIT NO,.: 78530105 ON A BUSINESS DAY LOCATED AT 1900 FIFTH AVENUE NORTH, BIRMINGHAM, ALABAMA 35203.. THIS DEMAND FOR PAYMENT SHALL BE DEEMED TO HAVE PRESENTED ON THE DATE ACTUALLY RECEIVED BY US. "BUSINESS DAY" MEANS ANY DAY OTHER THAN A SATURDAY, SUNDAY OR LEGAL HOLIDAY ON WHICH BANKING INSTITUTIONS IN THE STATE OF FLORIDA ARE AUTHORIZED OR REQUIRED BY LAW TO CLOSE. THE ORIGINAL LETER OF CREDIT AND ALL AMENDMENTS IF ANY MUST BE pRESENTED FOR PROPER ENDORSEMENT. 6. TIME AND METHOD FOR PAYMENT. (A). IF DEMAND FOR PAYMENT IS MADE IN STRICT CONFORMITY WITH THE TERMS AND CONDITIONS HEREOF, PAYMENT SHALL BE MADE TO YOU ON THE NEXT SUCCEEDING BUSINESS DAY. (B). PAYMENT UNDER THIS LETTER OF CREDIT SHALL BE MADE IN IMMEDIATELY AVAILABLE FUNDS IN ACCORDANCE WITH THE PAYMENT INSTRUCTION SET FORTH IN THE DRAWING CERTIFICATE. 7. GOVERNING LAW AND CUSTOMS. THIS LETTER OF CREDIT, IS SUBJECT TO THE UNIFORM CUSTOMS AND PRACTICE FOR DOCUMENTARY CREDITS (1993 REVISION)INTERNATIONAL CHAMBER OF COMMERCE PUBLICATIONS NO. 500. 8. IRREVOCABILITY. THIS LETTER IF CREDIT IS IRREVOCABLE. 9. COMPLETE AGREEMENT. THIS LETTER OF CREDIT INCLUDING THE EXHIBIT HERETO, SETS FORTH IN FULL THE TERMS OF OUR UNDERTAKING. REFERENCE IN THIS LETTER OF CREDIT TO OTHER DOCUMENTS OR INSTRUMENTS IS FOR IDENTIFICATION PURPOSES ONLY' AND SUCH REFERENCE SHALL NOT MODIFY OR AFFECT THE TERMS HEREOF OR CAUSE SUCH DOCUMENTS OR INSTRUMENTS TO BE DEEMED INCORPORATED HEREIN. AmSouth Bank Post Office Box 11007 Birmingham, Alabama 35288 (800) 284-4100 Telex: 6823023 S.W.I.F.T.: AMSBUS44 USA International Division PAGE NO.: 4 IKREVOCABLE STANDBY LETTER OF CREDIT NO.: 78530105 HEREBY AGREE WITH YOU THAT DRAFT(S) AND DOCUMENTS DRAWN UNDER AND IN COMPLIANCE WITH THE TERMS AND CONDITIONS OF THIS LETTER OF CREDIT WILL BE DULY HONORED UPON PRESENTATION AT AMSOUTH BANK, 1900 FIFTH AVENUE NORTH, .BIRMINGHAM, ALABAMA 35203. AMSOUTH BANK /A"U~HORIZED' SIGNATURE COMMUNITY ENGINEERING SERVICES, INC. ('ivil En!tineerin,q · P;urveyin,q · l)ro, iecl 31ana.qement July 20, 2000 Collier County Government Community Development Services Division 2800 North Horseshoe Drive Naples, Florida 33942 The Links at The Strand Engineer's Final Payment Confirmation To Whom It May Concern: Pursuant to Collier County Ordinance 97-17, this will certify that all professional fees associated with the above reference project have been paid in full. Sincerely, COMMUNITY ENGINEERING SERVICES, INC. Mark D. McCleary, P.E. President FL License No. 44052 MDM/cgy Cc: John Globetti S 5eng~PELICAN~GOI.F_COM~IMPROVEMhIract 12\Turnover~Engr Payment Ceil.doc 9200 Bonita Beach Road * Sui0c o , ,, 1 ,] · Bonita Springs, IL 34135 ~ , (941) 495-0009 · fitx (941~ 49~ -7934 3MMUNITY ENGINEERING SERVICES, NC. Civil En!lineerin!t · Nurve!ting * Project July 20, 2000 Collier County Government Community Development Services Division 2800 North Horseshoe Drive Naples, Florida 33942 The Links at The Strand Water Main Testing To Whom It May Concern: A representative of our firm has witnessed a successful two (2) hour pressure test of the potable water main constructed as part of this project. An average test pressure of 150 psi was maintained throughout the test for the potable water main in accordance with Collier County specifications. Sincerely, COMMUNITY ENGINEERING SERVICES, INC. Cyn'~hia G. Yanosik, P.E. FL License No. 45250 Cc: John Globetti S:~ng~PELICANXGOLF_COM~IMPROVEIvBtractl 2\Turnover\Water Main Test Cert. doc 9200 Bonita Bc:tch Road · Suite o ~ q L 34135 ,.., ,. * Bonita Si)rings, F ' ~ (941) 495-0009 · fi~ (941) 495-7934 Department of Environmental Protection South District Jeb Bush P.O. Box 2549 Governor Fort Myers, Florida 33902-2549 David B. Struhs Secretary Cynthia G. Yanosik, P.E., Authorized Agent Community Engin~ring Services, Inc. 9200 Bonita Boach Road, Suite 213 Bonita Springs, FL 34135 August 14, 2000 Collier County_ - PW The Links at Thc Strand (Collier County Regional WTP ) 167426-002-DSGP Southwest Coast EMA Dear Ms. Yanosik: This acknowledges receipt of certification that thc subject water distribution system extension has been completed in accordance with thc plans and related materials permitted by this agency under Permit Number 167426-002-DSGP dated April 26, 2000. Based on this certification and satisfactory bacteriological results, wc arc approving these facilities for service. Your continued cooperation in our water supply program is appreciated. Sincerely, O. James Oni Professional Engineer Water Facilities OJO/MFJ cc: Thomas E. Kuck, P.E. "More Protection, Less Process" Pr/hied on recycled paper. 88/82/2888 03:13 9414957934 ¢OMMUNII¥ ENGINEERIN P~GE 02 Florida Department of Environmental ProteCtion Twin Towers Offlce Bids., 2600 Bleir Stoae Road, T~lthe~e, Ftorid~ 32399-2400 DOMESTIC WASTBWATEP- COLLF_.CTIONfrgANSMISSION SYSTEMS CERTIFICATION Of COMPLETION OF CONSTRUCTION I~S'I1ttjCI'ION~: T~ to~ i~ ~c be completed ~nd ~obe ty~ or~ Permit ]No. :_ ~l-~O~PW~ ,. m RECEIVED WAIVER OF LIEN KNOW ALL MEN BY THESE PRESENTS, that Ken Raban, as Operations Manager, of Port of the Islands Construction, Inc., for and in consideration of Fifty Four Thousand Two Hundred One Dollar and gg/100 Ceres ($54,201 .gg) and other good and valuable considerations, lawful money of the United States of America, to me in hand paid, the receipt wbereofis hereby acknowledged, does hereby waive, release, remiss, and relinquish any and all right to claim any lien or liens for work performed or material furnished, or any kind or class of lien whatsoever on the following described property: THE LINKS AT THE STRAND - A portion of land located in Section 19, Township 45S, Range 26E, Collier County, Florida, specifically outlined below herein: Sanitary Sewer Facilities on Fairway Court at The Links at the Strand. Port of the Islands Construction, Inc. 4500 Executive Drive, Suite 300 Naples, Florida 34119 Name and Address of Firm or Corporation A~i'horized ~6p~esentative STATE OF ~/Or't~.rl_ ) ) SS: COUNTY OF ~O//,~'r ) The foregoing instrument was signed and acknowledged before me this /r~r~/~ day of ~-"{l/'~ ,2000 by er /;e4J A:~ ~:~o,r) who has produced X 'n ;uJ, as identification, and who (did) (did not) take an oath. Notary Public Signat~e (NOTARY SEAL) Notary Commission Number State of FLorida Department of HeaLth Office of Laboratory Services JacksonviLLe, Miami, Per~acola Tang)a, West PaLm Beech DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY Press hard, (5) copies SYSTEM NAME: SYSTEM I .D. NO: SYSTEM PHONE #: ~)DRESS: COUNTY: D ! STR I CT: COLLECTOR: COLLECTOR PHONE #: SAMPLE SITE (LocaLity or Subdivision): DATE ANO TIME COLLECTED: TYPE OF SUPPLY(Circle one): ~CJ~jl)B.U_Q,i~w__a,a~£~¥s~em *~Noncommunity water system Nontransient - noncommunity water system Private we[[ Swimming pool BottLed water Limited Use system TYPE OF SAHPLE(Circ[e one): CompLiance Repeat Replacement :i Hain c[earap~,~ We[[ survey Other (Check Box) [ [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO-~ COMPLETED BY LAB ANALYSIS METHOD: * MF,;, MTF MMO-MUG PA COLL. SAMPLE POINT CI NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * ResuLts in this column are presumptive. Total coliform and fecaL coLiform or E. coLi confirmation wiLL foLLow in 24-48 hours. P - CoLiforms are present C - ConfLuent growth A - CoLiforms are absent TNTC - Too numerous to coupt INVOICE ADDRESS (if different than address below): TA - Turbid, Absence of gas or acid INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of FLorida Department of HeaLth Office of Laboratory Services JacksonviLLe, Miami, PensacoLa Tampa, West PaLm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY Press hard, (5) copies SYSTEM NAME.' SYSTEM I.D. NO: SYSTEM PHONE #: ADDRESS: COUNTY: D I STR I CT: COLLECTOR: , ~ ~i ,;~ COLLECTOR PHONE #: SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: . ~ TYPE OF SUPPLY(Circle one): ~o;nmunity water sy[t.em~%Noncornmunity water system Nontransient - noncommunity water system p~e-'~-6~'-'-*-~wimming pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement ; Main clearance ~ Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COHPLETED BY COLLECTOR OF SAMPLE TO,~6~ COMPLETED BY LAB ANALYSIS ME THO0: C~1~~ ~To~ MMO-MUG PA COLL. SAMPLE POI NT C l NON RM F ! RM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * Results in this column are presumptive. Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND HAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOHPLETE COLLECTION INFORHATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: The Links at the Strand DATE: June 7, 2000 SANITARY SEWER SYSTEM Item Des~ Size ~ Unit Unit Total Price Price 1 PVC 3034 Sewer Main, 0'-6' Cut 8" 742 LF $12.38 $9185.96 2 PVC 3034 Sewer Main, 6'-8' Cut 8" 220 LF $14.59 $3209.80 3 PVC 3034 Sewer Main, 8'-10' Cut 8" 573 LF $19.90 $11402.70 6" 1600 LF $10.00 $16000.00 4 PVC 3034 Sewer Lateral 6" 56 EA $116.84 $6543.04 5 PVC Cleanout 6 Manhole, 0'-6' Cut 2 EA $1346.29 $2692.58 7 Manhole, 6'-8' Cut 2 EA $1616.60 $3233.20 8 Manhole, 8'-10' Cut I EA $1934.60 $1934.60 TOTAL SANITARY SEWER SYSTEM $54201.88 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OF MATERIALS, QUANTITIES OF MATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRAWINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN, AS OF THIS DATE. Personally Known, Sworn To & Subscribed Before Me This [g-Hq Day Of~ 2000 (Notary Public Nan~e &Se~l)'6 Certifying: K~'~Raban Operations Manager Port of the Islands Construction, Inc. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: The Links at the Strand DATE: June 7, 2000 WATER DISTRIBUTION SYSTEM Item Desc~ Size ~ unit 1670 1 1 PVC C-900, DR18 Water Main 10" LF 2 Gate Valve & Box 10" EA 3 90 Degree Bend, MJ 10" 2 EA 4 45 Degree Bend, MJ 10" 10 EA 5 22 1/2 Degree Bend, MJ 10" 7 EA 6 Fire Hydrant Assembly 6" 3 EA 7 Flushing Fire Hydrant Assembly 6" 1 EA 8 Permanent Bacterial Sample Point I EA 9 Air Release Valve 1 EA TOTAL WATER DISTRIBUTION SYSTEM Unit Total Price Price $20.73 $34619.10 $1032.20 $1032.20 $366.20 $732.40 $332.60 $3326.00 $332.00 $2324.00 $2065.85 $6197.55 $2765.85 $2765.85 $832.10 $832.10 $1039.20 $1039.20 $52868.40 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OF MATERIALS, QUANTITIES OF MATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRAWINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN, AS OF THIS DATE. Personally Known, Sworn To & Subscribed Before Me This Day Of'3- Id , 2_000 (Notaxy re, bile Na~ &Seah Q~ Certifying: j(e~/Raban ' ~ Operations Manager Port of the Islands Construction, Inc. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: The Links at the Strand DATE: June 7, 2000 SANITARY SEWER SYSTEM Item Description Size Quantity Unit Unit Total Price Price 1 PVC 3034 Sewer Main, 0'-6' Cut 8" 742 LF $12.38 $9185.96 2 PVC 3034 Sewer Main, 6'-8' Cut 8" 220 LF $14.59 $3209.80 3 PVC 3034 Sewer Main, 8'-10' Cut 8" 573 LF $19.90 $11402.70 4 PVC 3034 Sewer Lateral 6" 1600 LF $10.00 $16000.00 5 PVC Cleanout 6" 56 EA $116.84 $6543.04 6 Manhole, 0'-6' Cut 2 EA $1346.29 $2692.58 7 Manhole, 6'-8' Cut 2 EA $1616.60 $3233.20 8 Manhole, 8'-10' Cut 1 EA $1934.60 $1934.60 TOTAL SANITARY SEWER SYSTEM $54201.88 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OF MATERIALS, QUANTITIES OF MATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRAWINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN, AS OF THIS DATE. Personally Known, Sworn To & Subscribed Before Me This Day Of ~.~/_~ 2000 Certifying: KOfC~taban Operations Manager Port of the Islands Construction, Inc. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: The Links at the Strand DATE: June 7, 2000 WATER DISTRIBUTION SYSTEM Item Descri tp_3j_q~ Size ~ Unit I PVC C-900, DR18 Water Main 10" 1670 LF 2 Gate Valve & Box 10" I EA 3 90 Degree Bend, MJ 10" 2 EA 4 45 Degree Bend, MJ 10" 10 EA 5 22 1/2 Degree Bend, MJ 10" 7 EA 6 Fire Hydrant Assembly 6" 3 EA 7 Flushing Fire Hydrant Assembly 6" 1 EA 8 Permanent Bacterial Sample Point 1 EA 9 Air Release Valve 1 EA TOTAL WATER DISTRIBUTION SYSTEM Unit Total Price Price $20.73 $34619.10 $1032.20 $1032.20 $366.20 $732.40 $332.60 $3326.00 $332.00 $2324.00 $2065.85 $6197.55 $2765.85 $2765.85 $832.10 $832.10 $1039.20 $1039.20 $52868.40 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OF MATERIALS, QUANTITIES OF MATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRAWINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN, AS OF THIS DATE. Personally Known, Sworn To & Subscribed Before Me This Day Of~J-t.i Iq ,)000 Public ~qa~ & s~) Q~ Certifying: Ken/Raban Operations Manager Port of the Islands Construction, Inc. L O MMU'NI TY ENGINEERING SERVICES, NC. (~ivil Engineerin,q * ,~;urveym, t · l'rq]ect Mam~qemenl July 20, 2000 Collier County Government Community Development Services Division 2800 North Horseshoe Drive Naples, Florida 33942 The Links at The Strand Utilities Within Easements To Whom It May Concern: After reviewing the as-built plans and information provided by the surveyor, we hereby certify that all public water and sewer easements. Sincerely, COMMUNITY ENGINEERING SERVICES, INC. Cyn~a~a G. Yanosik, ~ FL License No. 45250 Cc: John Globetti contractor, developer and facilities fall within dedicated S 5engXPELICANXGOLF_COIVFxlMPROVEM\tract 12\Turnover\Utility Easement Cert.doc 9200 Bonita Beach Road · Suite 211~ · Boniin Sprixkgs, FL 34135 (92t, 1) ~95-0009 ,, fi~x (921· l) 495-79S4 WARRANTY The Undersigned, Port of the Islands Construction, Inc., does hereby warranty and/or guarantee the Sanitary Sewer facilities of The Links at the Strand, to be free from defects in material and workmanship for a period of one (1) year from the date of acceptance by the Collier County Board of County Commissioners. The undersigned party further agrees that they will, at their own expense, repair and replace all such defective work and all other work damaged by said defective work under this Warranty- Guaranty. It is further understood that the consideration for the giving of this warranty and/or guarantee is required by the General Conditions and Specifications under which the contract was let. DATE: June 7, 2000 Port of the Islands Construction, lnc. 'Kend~dban ' Operations Manager NOTARY PUBLIC STATE OF FLORIDA COUNTY OF COLLIER Sworn and subscribed to before me this ]t~,/4~ day of '~-'-/Z~t/ .... 2000. I My commission expires NOTARY PUBLIC Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt ITrans Number Date Post Date I Payment Slip Nbr ] 228042 10/17/00 9: 59:54 AM 10/17/00 UT 77099 PORT OF THE ISLANDS CONSTRUCTION THE LINKS/FAIRWAY CT @ THE STRAND Payor' PORT OF THE ISL. CONST IFee Code [ Description 42CYIN COUNTY INVOICES Fee Information GL Account 40800000011510000000 Amount Waived $188.89 Total $188.89 IPayment Code CHECK Account/Check Number 13751 Memo: DOR1086, W/O #029091/25156, + BACT Payments Amount $188.89 Total Cash Total Non-Cash Total Paid $0.001 $188.89 $188.89J Cashiedlocation: FOGLE_C / 3 User:. AVILES_L Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed: 10/17/00 10:00:49 AM S~P-28--~ ~9: 12 A~ P. 01 FIRE PREVENTIOH BUREAU 1780 tmmokalee Road · Naples, Florida 34110 (941) 597-9227 · Fax [941) 597-3522 Rescue August 28, 2000 Community Engineering Services 9200 Bonita Beach Road Suite 2 ~ 3 Bonita Springs, FL 34135 Re: Fire Hydrant Acceptance for Links at the Strand, 6011,6043, 6075, 6103 and 6107 Fairways Court Dear sir, The North Naples Fire Control and Rescue District has inspected for ownership and maintenance on the above hydrants. We have received payment for the above hydrant(s) and now accept ownership and maintenance. $125.00 per hydrant times number of hydrants 5 $23.00 per thrust block times number of hydrants 5 one flow charge at time of acceptance $35.00 Following are the results of the flow test: = $ 625. O0 = $115.00 = $ 35.00 Total: $775.00 Static: 80 Resid: 66 Flow: 1256 Pitot: 56 × 1 if you have any questions, please do not hesitate to give me a call at 597-9227. Sincerely, Karl K. Reynolds, Fire Marshal Fire Prevention Bureau Pd By CK#: 1006 COMMUNITY ENGINEERING SERVICES, INC. (!it, il Ett~littr'erin~.l * ,qttrt,<'!lit~.q * l'r~!ject M~tt~t.qem('ttt July 21, 2000 Collier County Government Community Development Services Division 2800 North Horseshoe Drive Naples, Florida 33942 The Links at The Strand Sewer Line Testing and Inspection To Whom It May Concern: Based on our review of the sewer videotapes, video reports, field inspections and lamping, the sanitary sewer system has been found to be in accordance with Collier County Land Development requirements. The sanitary sewer system for this phase of construction has been lamped and found to be in acceptable condition. Infiltration tests have been performed and found to be acceptable. No further testing was deemed necessary. Sincerely, COMMUNITY ENGINEERING SERVICES, INC. ,Cynthia G. Yanosik, P.E. Cc: John Globetti S:kengXPELICANr~GOLF_COMklMPROVEMktract 12\TurnoverXSewer Test and Inspect Cert.doc (94 1) q9500()9 * thx (941) 94199766~5~-~AINTS&COATINGS ~ 049 P03 JUN 06 ~00 11:56 Finest in Wasrewarer Structure Rehabilitation!" To Whom Ir .¥1ay Concern: inside, with Sher~. Willin.nzs brand (:oal Tar epoz? (:-ZOO. an acceptable bituminous or epo~ry ~e:der. 14ol l.l~)t).J ' ')41-'i*)"-<m45 ' '~41-0~1."'-7117 Ft.'( DATE OF REVIEW: PROJECT NAME: COLLIER COUNTY UTILITIES PROJECT VIDEO REVIEW 7-24-00 The Links at The Strand (North) ENGINEER OF RECORD~ CONSTRUCTION CONTRACTOR: VIDEO CONTRACTOR: Sewer Viewer COMMENTS: Lines and services acceptable RECOMMENDATIONS: ~ACCEPTABLE: ~--~ REVIEW NUMBERED COMMENTS IN ONE YEAR: ~ NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) ~OTHERRECOMMENDATIONS: COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION August 2, 2000 Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 Mr. Mark McCleary Community Engineering Services 9200 Bonita Beach Rd., Ste. 213 Bonita Springs, FL 34134 RE: The Links ~ Pelican Strand, Water & Sewer Dear Mr. McCleary: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on July 31, 2000. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418. Sincerely, Randy Casey Engineering Inspector DN/ts/fSInspection form Water Sewer cc: Diane Deoss, Engineering Technician, Public Works Joe Cheathan, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Don Nobles,Engineering Inspections Supervisor Randy Casey, Engineering Inspector Shirley Nix, Engineering Tech. H, Engineering Review Section File Phone (941) 403-2400 Fax (941) 643-6968 www. co.collier, fl.us