Loading...
Agenda 12/12/2017 Item #16E 412/12/2017 EXECUTIVE SUMMARY Recommendation to approve a Memorandum of Agreement with the National Park Service for utilization of a Park Service tower for the County’s P25 Radio system OBJECTIVE: To improve radio system coverage and performance, as part of the P25 system upgrade, in the Everglades area. CONSIDERATION: Contract 15-6409 for the P25 radio system implementation, which was approved by the Board on April 14, 2015, Agenda Item 11A, included funds for new communication sites. Collier County currently leases tower space at a commercial tower on Loop Road near the Dade County line to provide coverage in the southeast section of the County. The current location is at the eastern boundary of the County. The Oasis Ranger Station in the Everglades National Park is more centrally located and will improve radio system coverage along the Tamiami Trail corridor. In addition, co-locating with the National Park Service at this tower will facilitate interagency communication critical to public safety response in this area. The term for the arrangement is five years and either party may terminate with 60 days notice to the other. FISCAL IMPACT: Costs associated with relocation of the Loop Road site will not exceed the amount established in contract 15-6409. Costs for equipment maintenance and site operation are budgeted in the 800 MHz Inter-Governmental Communications Program, account number 188-140480. There are no costs associated with utilization of the National Park Service tower or for the required radio equipment space. This relocation will eliminate lease payments for the commercial tower space with an annual savings of approximately $15,000. GROWTH MANAGEMENT: There is no Growth Management Impact associated with this Executive Summary. LEGAL CONSIDERATIONS: This item is approved for form and legality and requires a majority vote for Board action. - JAB RECOMMENDATION: To approve the Memorandum of Agreement with the National Park Service and authorize the Chairman to execute same. Prepared by: John Daly, Telecommunications Manager, Information Technology Division ATTACHMENT(S) 1. Oasis National Park Service Tower Lease (PDF) 12/12/2017 COLLIER COUNTY Board of County Commissioners Item Number: 16.E.4 Doc ID: 4143 Item Summary: Recommendation to approve a Memorandum of Agreement with the National Park Service for utilization of a Park Service tower for the County’s P25 Radio system. Meeting Date: 12/12/2017 Prepared by: Title: Property Management Specialist, Senior – Facilities Management Name: Michael Dowling 11/03/2017 4:31 PM Submitted by: Title: Division Director - Facilities Mgmt – Facilities Management Name: Dennis Linguidi 11/03/2017 4:31 PM Approved By: Review: Administrative Services Department Paula Brethauer Level 1 Division Reviewer Completed 11/03/2017 4:39 PM Information Technology John Daly Additional Reviewer Completed 11/06/2017 7:55 AM Facilities Management Dennis Linguidi Additional Reviewer Completed 11/06/2017 2:45 PM Facilities Management Toni Mott Additional Reviewer Completed 11/07/2017 3:09 PM County Attorney's Office Jennifer Belpedio Level 2 Attorney of Record Review Completed 11/07/2017 4:53 PM Administrative Services Department Len Price Level 2 Division Administrator Review Completed 11/16/2017 12:13 PM Office of Management and Budget Valerie Fleming Level 3 OMB Gatekeeper Review Completed 11/16/2017 1:22 PM Office of Management and Budget Laura Wells Additional Reviewer Completed 11/16/2017 2:15 PM County Attorney's Office Scott Teach Level 3 County Attorney's Office Review Completed 11/17/2017 3:07 PM Public Utilities Operations Support Joseph Bellone Additional Reviewer Completed 11/20/2017 8:54 AM County Manager's Office Leo E. Ochs Level 4 County Manager Review Completed 11/29/2017 12:19 PM Board of County Commissioners MaryJo Brock Meeting Pending 12/12/2017 9:00 AM MEMORADUM OF AGREEMENT C5120170007 Betwecn UNITED STATES DEPARTMENT OF THE INTERIOR NAT10NAL PARK SERVICE BIG CYPRESS NATIONAL PRESERVE and COLLIER COUNTY OF FLORIDA This agreement is cntcrcd mto by and between the National Park Service(hereinafter“NPS''),Unitcd Statcs Department of the lntcrior, acting through the Superintendent of Big Cypress National Preservc (hercinafter “Prcserve'')and C01lier County,a political subdivision ofthe Statc of Florida(herCinafter``County''). ARTICLE I―BACKGROUND AND OBJECTIVES Thc ottcct市 C Of this Agrccmcnt is to establish thc terlns and conditions under which thc County will pro宙 de and insta∥ two antcnnas on a Preserve owned tower located at the Oasis Visitor Centcr, which wiH provide a critical clement ofthe County's radio system and provide long telHI coordination with the National Park Servicc. ARTICLE II―AUTHORITY ● This agreementis entered into underthc authority of 16 U.S.C.§lb(5). ARTICLE HI‐STATEⅣIENT OF WORK A.Thc Prcscrvc shall: 1. Providc thc ncccssary space on the Preserve owncd guyed tower located at 52105 Tamiami Trail East, Ochopee,FL 34141,to accommodate and support the County's antenna system,which is a critical element ofthe County's radio system. 2.Provide the necessary space in thc Preserve owned faciHty,attaCent to the tower,that will housc thc equipment necessary to supportthe County's antcnna system. B The County: 1. Based on the deterlnination of the attached structural analysis, the to、vcr can support the County's proposed loading,two 2 Db 812 antcnnas,with nlinor:nodiflcations. The modiflcations would entail replacemcnt ofthc cxisting guy wires and structural bracing to the tower at the location ofthe County's antennas.These modiflcations、vill bring the tower into compliance with the curcnt building code and are basic tower inaintenancc activitics. 2.Ate対 sting facility,the County wiH occupy interior space necessary to accommodatetwo communication equipment racks and an unintcrruptiblc power supply(UPS).The county win complete any required facility modiflcations to accommOdate County usc of the site which may include electrical, environmental,or grounding systems. 3. All instaHation and site modincation plans wiH be subnlitted to the Big Cypress National Park for approval prior to cominencement ofany、vork. ③ 4 The County wi∥be responsible for aH costs associated with any improvcments to thc to、vcr and thc facility. ARTICLE IV―TERM OF AGREEMENT This agreement sha∥bc cffective for a period of flve years'om the date of flnal signaturc,unless it is tcrrninated earlier by onc ofthe parties pursuant to Article IX that fb∥ows: ARTICLE V―KEY OFFICIALS A. Forthe NPS: Nikita Carty Big Cypress National Preserve 33100 Tamiami Trail E Ochopee, FL34141 239-695-tt26 B. Collier County Real Property Management 3335 East TamiamiTrail, Suite l0l Naples, FL34l12 Attn: Leasing Specialist With a mandatory copy sent to: Office of the Collier County Attorney 3299 East Tamiami Trail Naples, FL34112 Attn.: County Attorney Collier County Information Technology 3299 East Tamiami Trail- Suite 600 Naples, FL 34112 Attn. : Telecommunications Manager ARTICLE VI - PRIOR APPROVAL Not applicable ARTICLE VII _ REPORT AND/OR OTHER DELIVERABLES Upon request and to the full extent permitted by applicable law, the parties shall share with each other final reports of incidents involving both parties. ARTICLE VIII _ PROPERTY UTILIZATION Unless otherwise agreed to in writing by both parties, any properfy furnished by one party to the other shall remain the property ofthe furnishing party. ③ ARTICLE IX - MODIFICATION AND TERMINATION A. This agreement may be modified only by a written instrument executed by both parties. B. Either parry may terminate this agreement for reasons other than unsatisfactory performance of the other party, provided that they notify the other party with sixfy (60) days advance written notice. In the event that one party provides the other party with notice of its intention to terminate, the parties shall meet promptly to discuss the reasons for the notice and to try to resolve their differences amicable. The parties commit to using every reasonable means available, including the use of a neutral mediator if necessary, to try to avoid terminating this agreement. ARTICLE X _ STANDARD CLAUSES A. Civil Rights During the performance of this agreement, the participants agree to abide by the terms of the USDI-Civil Rights Assurance Certification, non-discrimination, and will not discriminate against any person because of race, color, religion, sex or national origin. The participants will take affirmative action to unsure that applicants are employed without regard to their race, color, religion, national origin, disabilities, age or sex. B. Promotions The Commission shall not publicize or otherwise circulate promotional material (such as advertisements, sales brochures, press releases, speeches, still and motion pictures, articles, manuscripts or other publications) which states or implies Governmental, Departmental, Bureau or Government employee endorsement of a product, service, or position which the (parfy) represents. No release of information relating to this agreement may state or imply that Government approves of the Commission's work product to be superior to other products or services. C. Public Information Release The Commission must obtain prior Government approval from the Superintendent of Big Cypress National Preserve for any public information release which refers to the Department of the Interior, any bureau, park unit, or employee (by name or title), or to this agreement. The specific text, layout, photographs, etc. of the proposed release must be submitted with the request for approval. D. Liability Provision Each party to this agreement will indemni$, save and hold harmless, and defend each other against all fines, claims, damages, losses, judgments, and expenses arising out of or fiom, any omission or activiry of such person organization, its representatives, or employees. {1n i S g.o .t', s\ czv- i s Swb' yec-t t-- -Ll^e- lin r;-lq-+; r-.-r o+ Se-+."r.', *-tco tr'eBr Flo./,d o S+*-1-^--tS - ARTICLE XI - SIGNATURES IN WITNESS WHEREOF, the parties hereto have executed this agreement on the date(s) set forth below. FOR THE NATIONAL PARK SERVICE: Name: TamaraWhittington Title; Superintendent Big Cypress National Preserve FOR THE COLLIER COUNTY:OF COUNTY COMMISSIONERS, COLINTY, FLORIDA PENNY TAYLOR, Chairman Attest: DWIGHT E. BROCK, Clerk By: Deputy Clerk Approved as to Form & Legality: ギT置 だ°■ メロ STRUCTURAL ANALYS:S REPORT OASIS SITE 220'GUYED TOWER COLLIER COUNTY,FLORIDA Prepared for Communications lnternational Tampa, FL 33634 Apn1 21,2017 KCI」0: 021603700C KCI 4505 Fa∥s of Neuse Road,Suite 400 Raleigh,North Caro∥na 27609-5210 (919)783-9214 Florida License Number:EB0004898 E「c S KohIFL License No 56545 Structural Analysis Report Oasis Tower A. B. c. D. E. KCI TECHNOLOGIES, INC,Employee-Osred Since I988 WWW KCICOM EXECUTTVE SUMMARY KCI rechnologies, lnc. has completed a feasibility structural analysis of the oasis tower. communications lntemational is proposing to add appurtenances to the tower. KCI sfudied a single loading case whlch consisted of the existing and proposed appurtenances with a 158-mph wind speed (uftimate $second gust) per the 2Oj4 Flodda Building Code for Collier County, Florirla with Exposure Category C, Topographic category 1 and Risk category ll. lce was not considered in this analysis. This analysis assumes that communications lntemational shall stack their propo$d transmission lines in a back lo back configuration on the Nortrwest tower face, such that one new line is exposed to wind. The resuhs indicate that with modifications, none of the struc{ural components of the tou,er will exceed the nominal loads established by the ANSI/T|A-222$ standa(dfor the poposed appurtenance configuration at the specified loadings. This rcport assumes modifications have been completed in accordance with the KCI Modification Drawings, dated 21 Apnl2017. Quality Tower completed the stuctural mapping of the tower and in the prccess discovered a few items that required maintenance. Please refer to Recommendations Section for further details. These are incorporated into the modification design as well for convenience. Structunal Analysis Report Oasis Tower The purpose of this report is to assess the feasibility of adding antennas and transmission lines to the existing struc,tur€, including whether or not structural modifications are required. Any modifications recommended herein are conceptual only. This is not a construction document. This report may not be suitable for bidding and definitely is not a substitute for completo and properly engineered plandspecifications required to accomplish any r€commended modifications. KCI Technologies, lnc. assumes no liability for use of this r€port for any other purpos€ than that for which it was intended. XoIa3 truu!t KCI TECHNOLOGIES, INC,Employce-OurEd Sincc l9tt WWW KCICOM Structu ral Analysis Report Oasis Tower A. PURPOSE / BACKGROUND Pursuant to the request of Mr. Rick Rewiskiwith Communications lnternational, KCI Technologies, lnc. was retained to conduct a structural analysis of the Oasis Tower. Communications lnternational is proposing to add appurtenances to the tower. Communications lnternational provided the following information for this analysis: - Proposed appurtenance information. KCI contracted Quality Towers to complete a structural mapping of the tower and to verify the general condition of the tower. - Geotechnical Evaluation Report by BJ Rock, BJR 17-128,14 April 2017.- Tower Study Foundation Report by BJ Rock, BJR 17-128, 13 April 2017 . KCI did not visit the site for this analysis. B. CONDITIONS INVESTIGATED The 220-ft guyed tower was originally designed and manufactured by Rohn. KCI could not obtain the original tower design loading. The tower is located on US Highway 41, Monroe Station, Collier County, Florida. KCI analyzed the self-supported tower using GuyMaster software by Weisman Consultants, lnc. KCI examined a single loading case including the existing and proposed appurtenances. *- Conversion based on 2014 Florida Building Code, Section 1609.1.1 Determination of wind loads, Exception 5. Loading Case Code Wind Speed and lce Loading1 ANSI/TIA-222-G& 2014 Florida Bu∥ding Code for Collier County,Flo百 da 158 mph (ultimate 3 second gust), No ice*122 mph (nominal 3 second gust), No ice KCI TECHNOLOGIES,INC Employee-Owned Since 1988 WWW KCICOM Structural Analysis Report Oasis Tower Existing Appurtenances (Base Elevations Shown): Proposed Appurtenances (in addition to the Existing/Future Appurtenances): C. APPLICABLE CODES AND PROVISIONS OF ANALYSIS KCI utilized the following codes and criteria to conduct the structural analysis: Nominal strengths used to evaluate the integrity ofthe structure were also in accordance with the above standard. Num ber Elevation Carrier Mount Antenna lnformation Transmission Lines1 220'Unknown Side Arm (1)- 20-ft 4 Bay Dipole antenna (1)- 7t8"2191'Unknown Leg (1)- 20-ft 4 Bay Dipole antenna (1)- 1t2',3187'Unknown Side Arm (1)- 40-ft Dipole antenna (1)-7/8"4156',Unknown Side Arm (1)- 20-ft 4 Bay Dipole antenna (1)- 7ti',5134'Unknown Leg ( 1)- 3-ft Standard microwave antenna (1)- 7t8"6109',Unknown Side Arm (1)- 20-ft Omni antenna (1)-7/8"745'Unknown Leg ( 1)- Empty Microwave mount N/A8 Unknown Leg (1)- Small Yaoi antenna (1)-1ノ 2・ Number Elevation Carrier Mount Antenna lnformation Transmission Lines9 220', Cnmrnr rninalinnc Leg /つ ヽ_月 KCnO^,r_nCo△40「0^l (1)- 1 5/8" & (1)- 7tg',lnternational Omni antennas Standard Title Date ANSVTIA-222-C-2005 Structural Standards for Steel Antenna Towers and SupDortino Structures August 2005 ANSVTIA-222-G-1-2007 Structural Standards for Steel Antenna Towers and Supporting Structures - Addendum 1 April 2007 ANSI′TIA-222-G-2-2009 Structural Standards for Steel Antenna Towers and Supporting Structures - Addendum 2 December 2009 KCI TECHNOLOGIES, INC. Employee-O*fled Since 1988 WWW KCICOM Structural Analysis Report Oasis Tower The following assumptions were made in the analysis: 1. The tower has been properly maintained. 2. The structural integrity of the tower has not been compromised. 3. All connections and fasteners are in accordance with AISC LRFD specifications.4. Communications lnternational shall stack their proposed transmission lines in a back to back configuration on the Northwest tower face, such that one new line is exposed to wind. 5. All information provided by Communications lnternational is accurate and correct. D. RESULTS The results indicate that with modifications, none of the structural components of the tower will exceed the nominal loads established by the ANSI/T|A-222-G standard for the proposed appurtenance configuration at the specified loadings. Su perstructu re Summary: !tem Results Elevation % Capacity (Maximum)Modifications Legs OK AII 77.6 None Diagonal Bracinq OK A∥95.0 None Horizontal Bracinq OK A∥67.2 None Leq Bolts OK A∥16.1 None Guy Wires OK A∥90.9 None Mast Foundation OK N/A * 44.9 None Guy Anchors OK N/A * 31.3 None*- Based on the foundation and soils information per BJ Rock reports. 4 KCI TECHNOLOGIES. INC.Employee-Owned Since I 988 WWW KCICOM Structural Analysis Report Oasis Tower E. RECOMMENDATIONS The results indicate that with modifications, none of the structural components of the tower will exceed the nominal loads established by the ANSI/TIA-222-G standard for the proposed appurtenance configuration at the specified loadings. This analysis assumes that Communications lnternational shallstack their proposed transmission lines in a back to back configuration on the Northwest tower face, such that one new line is exposed to wind. Quality Tower completed the structural mapping of the tower and in the process discovered a few items that required maintenance. These include the following and have also been included in the modification drawings: 1 . Re-tension the guy wires lo 10% of the breaking strength. All measured lower than a llowed per AN S lff I A-222-G standa rds. 2. There was significant corrosion on the tower base plate. This should be wire brushed and repainted. 3. The guy anchors have significant buildup of brush and other obstructions. These should be cleared away so that there is a clear path around each of the anchors. KCI TECHNOLOGIES. INC.Employee-Owned Since I 988 WWW KCICOM