Loading...
Vista GardensDATE: TO: FROM: RE: MEMORANDUM July 26, 2001 Maureen Kenyon, Supervisor, Clerk to Board Shirley Nix, Engineering Technician II~L/ Project Plan Review Vista Gardens Water and/or Sewer Facilities Acceptance On ~/~ , 200~The Board of County Commissioners granted final acceptance of the water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded documents, in order: 1. Bill of Sale 2. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. 10. 11. 12. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Copy of cashier's check & receipt for maintenance bond Engineer's final payment confirmation Certification of pressure testing of water and sewer lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities DER Placement-in-Service letter for sewer facilities Contractor's Final Release of Lien Lab results on bacteriological test for water lines Memorandum to Maureen Kenyon, Supervisor, Clerk to Board Vista Gardens Page Two 13. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 14. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 15. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 16. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 17. Letter from fire district regarding certification of field fire flow capacity testing 18. Electrical Contractor's certification on Pump Station electric service wire sizing and voltage drop, pursuant to National Electrical Code specification 19. Copy of pump station start-up report 20. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations If you have any questions, please call and advise accordingly. attachments doc:2094-2 Dwight E. Brock Clerk County of Collier CLERK OF THE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301 TAMIAMI TRAIL EAST P.O. BOX 4413044 NAPLES, FLORIDA 34101-3044 ORIGINAL OFFICIAL RECEIPT When Validated BY: LAURA DEPUTY CLERK RECEIPT: 3491425 NAME : PAYOR: REFNC: ENGINEERING REVIEW/S NIX BCC #113-138312-63-649 LP: 2 DOCUMENTS DOC TYP FILE ID B SALE 2837049 DEED 2837050 BOOK PAGE 2870 2192 2870 2193 DESCRIPTION RECORDING OF LEGAL INSTRUMENT P.R.M.T.F. RECORDING FEE INDEXING DOCUMENTARY STAMPS - 70 DOCUMENTARY STAMPS - 35 INTANGIBLE TAX SALES COPIES MISCELLANEOUS FEES INTANGIBLE PENALTY INTANGIBLE INTEREST RECORDING DEPOSITS REFUNDS AMOUNT 10.00 2.00 .70 DEPT: RECORDING TOTAL DUE: 12.70 Page 01 of 01 BILL OF SALE THIS BILL OF SALE, eyidencing the sale, and conveyance of the water and sewer utility facilities described herein is made this c_~9<9- day of ]/~rd,,c( .C7c~ 2000 by d VISTA GARDENS I, LTD, A FLORIDA LIMITED PARTNERSHIP (hereinafter referred to as "Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). W1TNESSETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: RIGHT OF WAY OF RATTLESNAKE HAMMOCK ROAD The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are freee from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. IN WITNESS WHEREOF, SELLER, has caused these presents to be executed that date and year first above written. State of Florida County of COLLIER VISTA GARDENS I, LTD., A FLORIDA LIMITED PARTNERSHIP BY ITS ENTITY GENERAL PARTNER, J.T.M. MANAGEMENT, INC., A FLORIDA CORPORATION ON BEHALF OF THE PARTNERSHIP By: The foregoing instrument Bill of Sale was acknowledged before me by JOHN T. MAGOCS, GENERAL PARTNER , J.T.M. MANAGEMENT, INC., ON BEHALF OF VISTA GARDENS, I, LTD, A FLORIDA LIMITED PARTNERSHIP WITNESS my hand and official seal this ~~day of _,~'~(~'O~ ~, 2000. IxN, l°;~YomP~n~ion' ' Expires 5¢ T. MAGOcs, PRESiDeNTr'/ *** 2837049 OR: 2870 PG: 2192 ** RECORDED in OFFICIAL RECORDS of COLLIER COUNTY, FL 08/03/2001 at 01:27PM DWIGHT E. BROCK, CL~RK R~C FBB 6.00 R~tn: SHIRLBY NIX/BNGINBNRING RBVIBW HORSBSHOB DRIVH BXT 5586 (affix notarial seal) UTILITY FA CILITIES WARRANTY DEED THIS INDENTURE made this c.9~ day of %~?.~, ~000, between VISTA GARDENS I, LTD., A FLORIDA LIMITED PARTNERSHIP, (hereinafter referred to as "grantor"), and the BOARD OF COUNTY COMMISSIONER~ OF COLLIER COUNTY, FLORIDA, AS GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WA TER-SEWER DISTINCT, its successors and assigns, (hereinafter referred to as "GRANTEE"). WI TNESSE TH: That said Grantor, for and in consideration of the sum ofTen Dollars and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land together with appurtenant easement rights for the operation, installation and maintenance of Said facilities, situate, lying and being in COLLIER County, State of FLORIDA, to wit:: RIGHT OF WAY OF RATTLESNAKE HAMMOCK ROAD And said Grantor does hereby fully warrant the title to said utility facilities and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A " Grantor and Grantee are used for singular or plural, as context requires. IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. Printed Name Witadss~nature Printed Name State of Florida County of COLLIER VISTA GARDENS I, LTD., A FLORIDA LIMITED PARTNERSH1PB Y ITS ENTITY GENERAL PARTNER, J.T.M. MANAGEMENT, 1NC., A FLORIDA CORPORATION ON BEHALF OF THE PARTNERSHIP JOHNT MAGOCS PRESIDENT ~ 2837050 OR: 2870 PG: 2193 *** RECORDED in OFFICIAL RECORDS of COLLIER COUNTY, PL 08/03/2001 at 01:277M DWIGHT E. BROCK, CLERK R~C FEE ~.00 DOC-.70 .70 SHIRLEY NIX/ENGINEERING REVIEW HORSESHOE DRIVE EX? 5586 The foregoing Warranty Deed was acknowledged before me by, JOHN T. MAGOCS, PRESIDENT OF J. T. M. MANAGEMENT, INC., GENERAL PARTNER, ON BEHALF OF VISTA GARDENS I, LTD, A FLORIDA LIMITED PARTNERSHIP. WITNESS my hand and official seal this (affix notarial seal) c:~~aY°f ~'~~(-J~'~'2000' /~ My Commission Expires k,~..___.~) Q~ OWNER'S AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLIER On this l0th day of April, 2001, before me personally appeared JOHN T. MAGOCS, on behalf of J.T.M. Management, Inc., a Florida corporation, the General Partner of VISTA GARDENS I, LIMITED PARTNERSHIP, owner of property to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to the plans and specifications, or extra items, used in the construction or repair of Water and Sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made by the Owner by, nor is any suit now pending on behalf of any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant further says that the utility facilities described herein are not included in, encumbered by, or subject to any real property mortgage, chattel mortgage, security agreement, Uniform Commercial Code financing statement, or any other encumbrance. Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of Collier County Water-Sewer District harmless against any lien, claim, or suit by any general contractor, subcontract, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A". WITNESS my hand and seal this 10th day of April, 2000. VISTA GARDENS I, LTD., A FLORIDA LIMITED PARTNERSHIP, BY ITS ENTITY GENERAL PARTNER, J.T.M. MANAGEMENT, 1NC., A FLORIDA CORPORATION ON BEHALF OF THE PARTNERSHIP - ~ohn T. Magoc~; l~re~dent STATE OF FLORIDA COUNTY OF COLLIER The forgoing owner's affidavit was sworn to and subscribed before me this l0th day of April, 2001 by John T. Magocs, as president of, J.T.M. MANAGEMENT, INC., a Florida corporation, on behalf of VISTA GARDENS I, LTD., a Florida Limited Partnership, who is.pprsonally .known tO me or who has produced .... as identification. /~ Commission Expires: [,x-.--/./(~ Notary eu~t'~e: ~l/~atur~e~ (/ This Instrument Prepared by: "~-'/~ ,. ,,k, David J. Szempruch, Esq., Bar fl983616 .].~ gA (._..~ ~,...J(J David J. Szempruch, P.A. Notary Printed Name 4910 Tamiami Trail North, Suit 210 .,,'L%. Naples, Florida 34103 (941) 261-8484 ~.~r %..~"~*"~ Ex,qres Janua~/14,2~ Exhibit "A" The existing right-of-way of Rattlesnake Hammock Rd., Section 16, Twp 50 S, Rng. 26 E., COllier County, Florida. STATE OF FLORIDA COUNTY OF COLLIER ATTORNEY'S AFFIDAVIT Before me, the undersigned authority, personally on this l0th day of April, 2001, appeared David J. Szempruch, who is to me well known, and having been sworn and under oath, deposes and states: My name is David J. Szempruch. I am over the age of twenty-one (21) years, am otherwise sui juris, and gave personal knowledge of the facts contained herein. I am a licensed attorney, Florida Bar #0983616, authorized to practice law, and am practicing law in the State of Florida. My business address is 4910 Tamiami Trail North, Suite 210, Naples, Florida 34103. My business telephone number is (941) 261-8484. My business mailing address is 4910 Tamiami Trail North, Suite 210, Naples, Florida 34103 This affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District to accept the dedication or conveyance of water and sewer utility facilities located within or upon the real property described on the Attached Exhibit "A", and further described as the existing Right-Of-Way of Rattlesnake Hammock Road, which is incorporated herein by reference, said land being located in Collier County, Florida. This Affiant has examined record title information to both the real and personal property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. The record owner of the real and personal property described herein is VISTA GARDENS I, LTD., a Florida Limited Partnership, organized and existing under the laws of the state of Florida on January 6, 1999 (hereinafter "Owner"). The owner acquired record title to the subject property by instrument recorded on December 31, 1998, in Official Records Book 2498, at Page 1091, Public Records of Collier County, Florida. The Affiant has examined the partnership information obtained from the Florida Secretary of State, the jurisdiction under which the entity was created and presently operates. The Owner identified herein is currently active and authorized to do business within the State of Florida. Those persons or entities authorized to execute the instruments on behalf of the Owner in conjunction with the conveyance of the subject real and personal property are identified below: General Partner: J.T.M. MANAGEMENT, INC., a Florida corporation. NOTE: A search of the records of the Florida Secretary of State shows that the above identified General Partner is a valid Florida corporation, and currently authorized to do business in the State of Florida. Page 1 of 2 0 The subject real and personal property is free of liens and unencumbered of record, subject only to the following: (a) Non-Exclusive Easement granted to the present and future residents of Parker's Hammock, recorded in O.R. Book 628, Page 3, Public Records of Collier County, Florida. (b) Non-Exclusive Easement granted for the purpose of road right- of-way recorded in O.R. Book 780, Page 89 through 116, inclusive, Public Records of Collier County, Florida. (c) Non-Exclusive Easements granted to Florida Power and Light for Utility Purposes, and recorded in O.R. Book 2089, Page 217, and O.R. Book 2526, Page 2367, Public Records of Collier County, Florida. (d) Ad valorem taxes for the current year. (e) Notices of Commencement recorded in O.R. Book 2670, at Pages 3084, 3086, 3088, 30090, 3092, 3094, and 3096, Public Records of Collier County, Florida. Affiant further states that the information contained in this Affidavit is true, correct and current as of the date this Affidavit is given. FURTHER AFFIANT SAYETH NAUGHT DATED this l0th day of April, 2001 David J. Szempruch Affiant Typed Name STATE OF FLORIDA COUNTY OF COLLIER The foregoing Attorney's Affidavit was sworn to and subscribed before me this l0th day of April, 2001, by David J. Szempruch, who is personally known to me. My Commission Expires: (Notary Seal) l~r~nted ~ame of Notary Page 2 of 2 Exhibit "A" The existing right-of-way of Rattlesnake Hammock Rd., Section 16, Twp 50 S, Rng. 26 E., COllier County, Florida. COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DMSION ENGINEERING REVIEW SECTION April 17, 2001 PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Terry Kepple Kepple Engineering 3806 Exchange Avenue Naples, FL 34104 Re: Vista Gardens Dear Mr. Kepple This is to inform you that the above referenced project has been granted preliminary approval on April 13, 2001 by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly,yours, _ , Shirley Engineeri'ng~Technician II CC: Paul Mattausch, Water Director Lisa Taylor, Public Works PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us ~'OOO i, BP, 8~,~' ':OP, ?0 i,t, ~,L,~I,: [[' l,O ~,00 ,'OOO ;I, 8& 5&,' ':0 & ?0 ~,1, i, ~, c~: ,' i,O i, O0 r=,~, Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number Date Post Date Payment Slip Nbr 257783 04/13/2001 12:10:54 PM 04/13/2001 MS 84113 JOHN MAGOCS JTM MANAGEMENT VISTA GARDENS Payor: CITIZEN COMM BK/MAGOCS Fee Information Fee Code Description GL Account Amount Waived 12BOND DEPOSITS-COMM DEV (CASH BOND 167000000022011300000 $270.00 12BOND DEPOSITS-COMM DEV (CASH BOND 67000000022011300000 $1414.00 Total $1684.00 Payments r Payment Code Account/Check Number Amount CHECK 12656 $270.00 CHECK 12624 $1414.00 Memo: Total Cash Total Non-Cash Total Paid $0.00t $1684.00 $1684.00~ Cashier/location: FROLOFF_E / 1 User: NIX_S Collier County Board of County Commissioners Printed:04/13/2001 12:12:27 PM CD-Plus for Windows 95/NT 3806 Exchange Avenue · Naples, Florida 34104 · (941) 403-1780 · Fax (941) 403-1787 Shirley Nix Project Plan Review 2800 N. Horseshoe Dr. Naples, FL 34104 April 4, 2001 Re: Vista Gardens Water & forcemain Dear Ms. Nix, Please be advised that this office has been compensated in full on this project. Respectfully, ~--~j~.~ Terrance L. Kepple, P.E. Kepple Engineering, Inc. 3806 Exchange Avenue · Naples, Florida 34104 · (941) 403-1780 · Fax (941) 403-1787 Shirley Nix Project Plan Review 2800 N. Horseshoe Dr. Naples, FL 34104 April 4, 2001 Re: Vista Gardens Pressure test Water & forcemain Dear Ms. Nix, A pressure test of the water line and forcemain, for the referenced project, was made on July 21, 2001. The water line was tested to 150 psi for 2 hours. The forcemain was tested to 100 psi for 2 hours. I hereby certify the water line and forcemain as passing the required pressure test. Respectfully, Kepple Engineering, Inc. Department of : Environmental Protection, ~==-~=== ~:: South District Jeb Bush P.O. Box 2549 Governor Fo~ Myers, Florida 33902-2549 David B. Struhs Secretary October 26, 2000 John T. Magocs, General Partner Vista Gardens I 4100 Corporate Square, Suite 105 Naples, FL 34104 Re: Collier County - PW Vista Gardens (Collier County Regional WTP) 169591-001-DSGP Southwest Coast EMA Dear Mr. Magocs: This acknowledges receipt of certification that the subject water distribution system extension has been completed in accordance with the plans and related materials permitted by this agency under Permit Number 169591-001-DSGP dated May 31, 2000. Based on this certification and satisfactory bacteriological results, we are approving these facilities for service. Your continued cooperation in our water supply program is appreciated. Sincerely, Professional Engineer Water Facilities OJO/MFJ/klm cc: Terrance L. Kepple, P.E. Thomas E. Kuck "More Protection, Less Process" Printed on recycled paper. ?"ff-=~;~? ~, Florida Department of ~,nvironmental Regulation Domestic Wastewater Collection/Transmission Systems Certification of.Completion of Constructior~¢¢¢~ INTRUSIONS: This form is to ~ completed and submiRed to the Depa~ment, prior to placing the ~stem mtoo~mtion. A collec- tionltransmission ~stem should not be placed into operation without prior Depa~ent approval. MI information is to be ~ped or printed in ink and all blan~ must be filled. Name of Project: Name of Owner: Name of design engineer and Florida registration number (if different from engineer signing certification): Date(s) of connection to existing system or treatment plant: Treatment plant ser~i_ng project 'Name: ('~//~"~'~ ~/F'~ DE~ identification number (also known as GMS identification number): Substantial deviations from the approved plans and specifications (attach additional sh~ Page 1 ~ 3 FINAL WAIVER AND RELEASE OF LIEN STATE OF FLORIDA COUNTY OF COLLIER THE UNDERSIGNED LIENOR, BEING THE CONTRACTOR ON THAT CERTAIN CONSTRUCTION AGREEMENT COMMONLY KNOWN AS: VISTA GARDENS PHASE I, DO HEREWITH ACKNOWLEDGE THAT I HAVE RECEIVED PAYMENT IN FULL FOR WORK DONE ON SAID PROJECT AND DO HEREBY THIS DOCUMENT SWEAR AND AFFIRM THAT ALL BILLS AND LABOR, MATERIAL OR OTHER CLAIMS OR LIENS INTERESTS INCURRED BY REASON OF MY CONTRACT ON OR PRIOR TO SAID DATE HAVE BEEN PAID IN FULL. OR: KYLE CONSTRUCTION, INC. SUBSCRIBED AND SWORN TO BEFORE ME THIS DAY OF 2000. NOTARY PUBLIC DRINKING WA TER BACTERIOLOGICAL ANAL YSIS DOH#E5575[~ ~ use Rec'.d t 1 a45 TESTED Time: t3z/~5 TO 5¥STEK N~: ADDRESS: Pass ha'd, (5) SYSTEN I.D. NO: SYSTEH P~E ~LLECT~ ~LE SITE (L~atity or S~ivision): DATE ~ TZHE COLLECTED: T?PE Of ~PPLYCCircLe ~): 732.- EZ558 11 coca, unity water system ''#oncomaunity water system #ontransient - noncmmunity water system pri~ate'we['t--' ~aiaming pool aotZt~ uacer Limit~ Use TYPE OF ~4PLECCircte ~): C~lia~e Re.et Rep&ac~nt WeLL O~her (Check gex) ~ [ ~ Distri~tion [ [ ] Rau ... to c~ty ~btic health TO SE c;OKPLETI~D pY COLLECTOR o.r SAKT)LE TO ~BE CCKNP~i~TEO BY LA9 ANALYSIS HETHO0: (.HF.~." ' MTF HMO-MUG PA COLL. SM4PLE POINT CL NON COiF IRH CONF IR/R gO. (Specific Address) RE$'D pH COLIFORI4 *TOTAL TOTAL FECAL E. COLI SANPLE NUMBER ResuLts in this coL~ are presumptive. TotaL coliform and fecal coliform or L. coL~ confirmatia~ wiLL foLLo~ in 2~-~ h~s, P - Cotifor~ are present C - C~ft~t gr~th TA - Turbid, A~e of gas or acid A ,~oliforms are a~ent TgTC ' T~r~s to co~t IN~I~ ~DRESS ((f different chin ~reis ~[~): [NTERPRETATI~S-RE~S BY. PR~R~ REVIE~R AND MAILING ADORESS OF PERSON/FII~ TO RECEIVE REPORT REVIEUI#6 OFF/CIAL: TITLE: SATISFACTORY INCO#PLETE COLLECTION INFORMATION REPEAT SAL4PLES REPLACEI~NT SJU4PLES . scare of FLorida Office of' Liborit~Y S4rvices Tadq~, UeGt Piti bach DRINKING WATER BACTERIOLOGICAL ANALYSIS FDOH#E~ST~R [Aa USE ONLY Rec' d ! [ t00 TE6TEP Time: 11r45 TO t2:30 Press half. (5) copies - - ~. Col'tier County 61e~ot~ Dept 5i14069 /J,c-. ..... SYSTEH I.D. NO: SYSTEH V I'3TA GARDENE. ~LE SIIE (L~atity or S~ivisi~): DATE ~D TINE COLLECTED: 1~--~ TYPE OF SUppLYcCirc[e or~e): C~nity uater syst..e~, t~ortc0mltrmi%y ~ater syst~ N~tr~nsient ~tty uater systm "pr~"a~t'¥ ~;mi~ ~L Bott[~ water kimit~ Use syst~ · .~ ~e[ [ surv~ Other TYPE OF ~,.E(Circ[e one)= C~[fa~e Re.at R~[ac~n~. ~' ~In c[eara~e . (Ch~k Box) [ ] Check here if p~t ~ [ ] Oistrt~tim to c~ty ~Lic heaLth mit 'fO BE COI4PLETED BY COLLECTOR OF SANPL,~ . ANALys]i HETH~: / HE ~ HTF WO*W~ PA COLL. S~LE PEIN1 C[ - ~ ~%RN ~O. (S~cific A~re$~) RES'D pH COLIF~ ~TOTAL TOTAL ~i 20 +20 F. H~ ~. ~. 5 B. 7~ ~ 0010 -05~ p · Cotiform are preset C - C~fi~nt gr~th TA - Turbid, A~e of 9a; or acid A .* Colifor~ ar~ absent TNT; - T~ ~reus to ~o~[ iNTEKPRETATI~S-R~RES BY. PEC~ KEVIE~R [~tCE ~RESS (if d~ffer~t thru ~ress EU~E AI~ ItA%LING ~DDRES$ OF PERSON/FII~I TI) REC~iVE REPORT REV[EgI~G oFFIC%AL~ TITLE: ( ) ( ) SAT%SFACTORY ( ) INCO#PLETE COLLECTION $NFOItl4ATION ( ) REPEAT SA/,IPLES ( ) REPLACEMENT ~d~PLES 3806 Exchange Avenue Naples, Florida 34104 · Vista Gardens Final Cost April 9, 2001 (941) 403-1780 · Fax (941) 403-1787 ltem Description 1. 3" PVC forcemain 2. Lift station 3. 8" Fire line 4. Hydrant (complete) 5. Backfiow 6. Hot-tap (water) 7, Hot-tap (sewer) TOTAL Quantity 220 If Lump sum 380 If 2 each 1 each 1 each 1 each Unit Cost $5.00 $4,500.00 $8.00 $750.00 $4,500.00 $1,200.00 $1 ~.000.00 Cost $1,100.00 $4,500.00 $3,040.00 $1,500.00 $4,500.00 $1,200.00 $1 ~.000.00 $16,840.00 3806 Exchange Avenue · Naples, Florida 34104 · (941) 403-1780 · Fax (941) 403-1787 Shirley Nix Project Plan Review 2800 N. Horseshoe Dr. Naples, FL 34104 April 4, 2001 Re: Vista Gardens Water & forcemain Dear Ms. Nix, Please be advised that all County accepted utility facilities are located within the existing R/W of Rattlesnake Hammock Rd. Only the private portion of the utilities are located on the property. Terrance L. Kepple, P.E. Kepple Engineering, Inc. KYLE CONSTRUCTION, INC. 3656 Pro~e~t ~v~ GUARANTEE OF MATERIALS & WORKMANSHIP To: JTM MANAGEMENT 4100 CORPORATE SQUARE STE 116 NAPLES, FL 34104 Job: VISTA GARDENS Services rendered are warranted by KYLE CONSTRUCTION, INC. to be free from defects in material and workmanship under normal use for a period of one (1) year from the completion & acceptance date of the job. ACKNOWLEDGEMENT By: KYLE CONSTRUCTION, INC. L~,~b~:a-h~n, Pr~si~lenf Job Completion Date: APRIl A. 90~1 Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt iTrans Number ' Date Post Date Payment Slip Nbr 239506 12/22/2000 2:37:03 PM 12/22/2000 UT 79932 KYLE CONSTRUCTION, INC. 6265 VISTA GARDENS WAY OFF IMMOKALEE RD/VISTA GARDENS Payor: KYLE CONST Fee Information Fee Code Description GL Account Amount Waived 142CYIN COUNTY INVOICES 40800000011510000000 $337.18 Total $337.18 Payments IPayment Code Account/Check Number Amount CHECK 8161 $337.18 Total Cash Total Non-Cash Total Paid Memo: DOR1162, W/O #030827/028574~25193, RE-FLUSH NEW LINE $0.001 $337.18 $337.18~ Cashiedlocation: FOGLE C / 3 User: CALLIS P Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:04/06/2001 9:29:44 AM GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-6901 (941) 455-2121 ° FAX (941) 455-7917 March 27, 2001 John Magocs JTM Management, Inc. 4100 Corporate Square #116 Naples, Florida 34104 Dear Mr. Magocs: Subject: Hydrant Flow Tests - Vista Gardens On March 23, 2001, the Golden Gate Fire Control & Rescue District did a flow test on two (2) fire hydrants at Vista Gardens. The results are: Hydrant 16502627 - 6275 Vista Garden Way 68 Static PSI 52 Residual PSI 40 Pitot Flow PSI 1920 at 20 PSI Residual Hydrant 16502628 - 6265VistaGardenWay 68 Static PSI 52 Residual PSI 40 Pitot Flow PSI 1920 GPM at 20 PSI Residual Before completion of the project, thc hydrants need to be painted OSHA safety yellow. Thc caps need to be painted OSHA safety light blue. Also, blue road reflectors need to be installed to show location of all hydrants. This Fire District does not accept ownership nor does it maintain fire hydrants after their installation. Total due the Golden Gate Fire Control District for the two (2) flow tests is $70.00. DJA/pm Enclosure Golden Gate Fire Department Hydrant Flow Test By Hydrant Hydr ID In "16502627 ","16502628 1650262'! 6275 VISTA GARDEN WAY Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI 03/23/2001 68 52 40 0 1061 1920 2127 2318 13 Lowe Michael, J Subtotal Flow Tests: 1 )tin: 1061 1920 2127 2318 Max: 1061 1920 2127 2318 Avg: 1061 1920 2127 2318 16502628 6265 VISTA GARDEN WAY Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI 03/23/2001 68 52 40 0 1061 1920 2127 2318 13 Lowe Michael,J Subtotal Flow Tests: Total Flc,w Tests: 1 Min: 1061 1920 2127 2318 Max: 1061 1920 2127 2318 Avg: 1061 1920 2127 2318 03/26/2001 13:13 * Scheduled Flow Test Page t PO BOX 8115 NAPLES, FL 34101 Phone: FA~ 94~-6S9-~3~6 I I Date: April 12, 2001 Collier County Planning Review Engineering Dept. Attn: Shirley Nix Reference: Bista Gardens 1 LTD 6265 Parkers-Hammock Rd. Naples, Florida JDC Electric, Inc. Certifies that electrical wiring for Lift Station at above address meets National Electrical Codes and the Electrical wiring is sized above National Electrical Code for this Installation. John D. Comperatore JDC Electric, Inc. President -- A company in the Cardo Group Shipping: ABa Pumps Inc. 949 Shadick Drive Orange City, FL 32763 (904) 775-6353. FAX (904) 775-3272 Mail: ABa Pumps Inc. P.O. Box 741087 Orange City, FL 32774-1087 PRODUCT START-UP REPORT Customer: Job Site: Engineer: -. . / Model No.: ?~, ~5~/~ ~, v~ IMP: Voltage: ~- '~' ~ ,' Design Condition: I ~ ~ ~ O/ FLA. ~. ~ Date of Start-Up: ~- 2 ~ - O ~ Date Shipped: ~ i -' ,- S.O. No.: ~5-1 ~ PumpS/N: ~Oo/~l/Oo 1. General condition of pump(s) at start-up Pump(s) were stored~months-lndoors ~ Outdoors Wer3 pump cable ends properly protected? Yes/¥' No If not, explain 2. Check for proper installation of: Uppgr guide rail bracket(s) bolted securely Power & lifting cables properly secured Guide rail base(s) properly secured 3. Control Panel: Genera~ condition at start-up O, ~'. Man Jfacturer ~,~ f}~?L: ~-~ /~ 7(: ~ ManufacturerlDNo. ~/I 5/'z) ~7 ~t t~'~ ~'-~ 4. Volta,ge Check: A. Incoming Line to Line L1 x2 L2x3 L1 x3 L3xG B. Line to Ground: L1 xG L2xG C. Voltage to Control Breaker D. Voltage out from Control Trans: / 2 I // , _~. '._ L~ning Arrestor on Normal Line Side _~_~h~sca~enM~;;~ "Wild" Leg Properly Installed _L~_ ps-Megger-Check Closure on Thermals ._.~umps Properly Wired .._v._ Rotation Correct / Float switches tested per instructions in manual: v/ DRAW DOWN TES~--'~, Wet Well Die 36"// 48" Gal./Inch 4.42 7.8~ 1 60" 72" 84" 96" 108" 120" 2.17 17.82 23.98 31.32 39.64 48.93 Pump 1 Pump ,~ Start ~, ¥, c~ ~I ' ~ Finish ,~,c~ ,, ,~ ~,, ,, Draw Down ~ ' ~ ,, Time &~' ~-: , ~ 0 ~ ,~. Flow Rate '~'t ¢ I%,,~ ~,~, ~ p ~ Disc. Pressure Gauge Corr. ~ ~ TDH Check for current balance: Pump 1 Pump 2 T1 = ~' amps(S) T1 = '. ¥ amps(S) T2 = ~' ~ {"- amps(R) T2 = ./,.. ~' amps(R) T3 = ~, ~ amps(C) T3 = ~-7, ~'~ amps(C) 8. NOTES: 9. Personnel associated with job: Present at start-up: Name Yes No Customer Contractor 1~,,~1 ~ t; ~' c> ~.~T'. Engineer ~ Representative 12, ./-~ [/_~ ~s'/'~ The equipment has been inspected and is ready for permanent operation. Started by: ' Customer Appro I:v~~. Date: .~""' .~-~--~' COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION April 16, 2001 PLANNING SERVICES DEPARTMENT 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Mr. Terrance L. Kepple, P.E. Kepple Engineering 3806 Exchange Avenue Naples, Florida 34104 941-403-1780 Re: Vista Gardens, Water and Sewer Dear Mr. Kepple: A final inspection was conducted on the above referenced project by Dick Roll of the Engineering Review Section of the Planning Services Department, effective April 12, 2001. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Dick Roll at (941) 403-2410 or Don Nobles at (941) 403-2391. Sincerely, Dick Roll, Engineer II H:Engineedng-lnspections Letters/Inspections Water & Sewer/ts/RR C: Lisa Taylor, Engineering Technician, Public Works Joe Cheatham, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Diane Deoss, D.O.R. Billing Supervisor Don Nobles, Engineering Inspections Supervisor R,a.ndy Casey, Engineering Inspector S~ N~, :EHg~ng Tech. II, Engineering Review Section File PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us