Island Walk, Phase 4BMEMORANDUM
DATE:
TO:
FROM:
RE:
July 11, 2001
Maureen Kenyon, Supervisor, Clerk to Board
Shirley Nix, Engineering Technician II
Project Plan Review
Island Walk, Phase 4B
Water and/or Sewer Facilities Acceptance
On ~~f~ // , 200_~The Board of County Commissioners
granted final acceptance of the water and/or sewer facilities
within the above-referenced project.
Attached, please find the following recorded documents, in order:
1. Bill of Sale
2. Utilities Facilities Warranty Deed
Also, please find attached the following documents for your
files.
10.
Owner's Affidavit
Attorney's Affidavit
Copy of preliminary approval letter from Engineering
Review
Engineer's final payment confirmation
Certification of pressure testing of water lines by
Engineer of Record
Certification of pressure testing of sewer lines by
Engineer of Record
Bacteriological clearances (DER certification) for
water facilities
DER Placement-in-Service letter for sewer facilities
11. Contractor's Final Release of Lien
Memorandum to Maureen Kenyon, Supervisor, Clerk to Board
Island Walk, Phase 4-B
Page Two
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Lab results on bacteriological test for water lines
Verification of final cost (Detailed: quantities,
sizes, unit cost, total cost, etc.)
Letter by Engineer certifying that all water and/or
sewer facilities are located within the public
right-of-way or dedicated easements
Contractual Guarantee for material and workmanship for
a period of at least one year after the Board of County
Commissioners' acceptance 'for both water and sewer
facilities
Payment of water usage, laboratory and administrative
charges for filling, flushing and bacteriologically
certifying water lines from invoice prepared by the
Utilities Division
Letter from fire district regarding certification of
field fire flow capacity testing
Copy of backflow prevention assembly test report
Certification of the inflOW/infiltration test for the
sewer lines by Engineer of Record
Coating certification of man holes, wet wells and dry
well from manufacturer
Electrical Contractor's certification on Pump Station
electric service wire sizing and voltage drop, pursuant
to National Electrical Code specification
Copy of pump station start-up report
Copy of video tape test report
Letter from Compliance Services section certifying that
the final inspection reveals that the Utility
facilities have been constructed in accordance with
County ordinances and regulations
Memorandum to Maureen Kenyon, Supervisor, Clerk to Board
Island Walk, Phase 4-B
Page Three
If you have any questions, please call and advise accordingly.
attachments
doc:2094-2
County of Collier
CLERK OF THE CIRCUIT COURT
COLLIER COUNTY COURTHOUSE
3301 TAMIAMI TRAIL EAST
P.O. BOX 4413044
NAPLES, FLORIDA 34101-3044
Dwight E. Brock
Clerk
By:
DEPUTY '"CLERK
OFFICIAL RECEIPT V#= 2521441
When Validated
REG#: 01 CASH:
CHECK~
CD: BILLED:
AMT PAID:
07/26/200Z
.00
.00
.00
.00
RECEIPT: 3485412
NAME:
PAYOR:
REFNC:
ENGINEERING REVIEW / S N
BCC $113 138312 63 6490
LP: 2 DOCUMENTS
DOC TYP FILE ID BOOK PAGE
B SALE 2833099 2865 3107
DEED 2833100 2865 3110
DESCRIPTION
RECORDING OF LEGAL INSTRUMENT
P.R.M.T.F. RECORDING FEE
RECORDING OF LEGAL INSTRUMENT
DOCUMENTARY STAMPS - 70
DOCUMENTARY STAMPS - 3~
INTANGIBLE TAX SALES
COPIES
MISCELLANEOUS FEES
INTANGIBLE PENALTY
iNTANGIBLE INTEREST
DUE FROM BOARD OF COUNTY COMM
AMOUNT
26.00
4.00
.7O
30.70-
DEPT: RECORDING
TOTAL PAID:
DUPLICATE
Z/Z abed ,~vgg:o~ ~O-E-6n¥ :8008 I~ZZ ~1:'6 ,~0NI080038 N83'10 :~{8 %ues
Prepared by/Return to:
William E. Shannon, Esq.
4500 PGA Boulevard, Suite 400
Palm Beach Gardens, F1 33418
2833099 OR: 2865 PG: 3107
RiCORDID ~n O~ICIA;. R~CORDS of COU. IIR COUN?¥,
07/26/2001 at 09:38~ DWI~Y i. BROCK, CLiIK
~C ~! 15.00
~e~:
IX~ 5586
BILL OF SALE
THIS BILL OF SALE evidencing the sale and conveyance of the
water and sewer~ utility facilities described herein is made this
/5-~ day of /~/'~--~_ 2000, by ISLAND WALK DEVELOPMENT
COMPANY, a Florida corporation (hereinafter referred to as
"Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY,
FLORIDA AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO
THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its
successors and assigns, (hereinafter referred to as "Buyer").
W I TNE S S E TH
That said Seller, for and in consideration of the sum of Ten
Dollars ($10.00) and other good and valuable consideration to the
Seller in hand paid by the Buyer, the receipt whereof is hereby
acknowledged, has granted, bargained, sold, transferred, set over
and delivered, and by these presents does grant, bargain, sell,
transfer, set over and deliver unto the Buyer, and the Buyer's
heirs, successors and assigns forever, all those certain water and
sewer utility facilities lying within the following described land,
together with appurtenant easement rights for the operation,
installation and maintenance of said facilities, situate, lying and
being in Collier County, Florida, to wit:
See attached Exhibit A
The Seller, for itself and its successors, hereby covenants to
and with the Buyer and its successors and assigns that it is the
lawful owner of the said goods and chattels herein referred to as
utility facilities; that said goods and chattels are free from all
liens and encumbrances; that it has good right, title and authority
to sell same, and that it will warrant and defend the same against
the lawful claims and demands of all persons whomsoever. Seller
and Buyer are used for singular or plural, as the context requires.
OR: 2865 PG: 3108
IN WITNESS WHEREOF, Seller has caused these presents to be
executed the date and year first above written.
Witnesses:
ISLAND WALK DEVELOPMENT
COMPANY, a Florida corporation
Harmon D. Smith, V.P.
STATE OF FLORIDA
COUNTY OF PALM BEACH
The foregoing instrument was acknowledged before me this
day of _/t/~J~<~ , 2000 by Harmon D. Smith, as Vice
President of ISLAND WALK DEVELOPMENT COMPANY, a Florida
corporat ion.
Notary Public State of FlorirY'
CHRISTINE SCALAMANDRE
Commission :~ CC742794
Expires 8131/2002
Notary Public
Personally known / OR Produced Identification
Type of Identification Produced
P: ~Counsel ~CS\ ISLANDWK~wat er-sewer\BillSalePh3A, wpd
WilsonMiller
New Directions In Planning, Design & Engineering
2865
PG:
3109
Description of part of Islandwalk Phase Four,
Plat Book 34, Pages 35 through 40, Collier County, Florida.
(Islandwaik Phase Four less Ossabaw Way)
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, being
more particularly described as follows;
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, Less
the following described parcel;
BEGINNING at the Northwest comer of said Islandwalk Phase Four;
thence along the north line of said Islandwalk Phase Four; South 89°56'27" East 96.34 feet to the north XA
comer of Section 33, Township 48 South, Range 26 East, Collier County, Florida;
thence continue along said north line of Islandwalk Phase Four, South 89057'09'' East 358.62 feet;
thence leaving said line South 05°01'41" East 721.10 feet;
thence South 12°57'58" West 642.73 feet;
thence South 13010'59" East 792.79 feet to a point on the southerly line of said Islandwalk Phase Four;
thence along said line South 89°00'00" West 704.19 feet to a point on the west line of said Islandwalk
Phase Four;
thence along said line in the following Three (3) described courses;
1. North 01°00'00'' West 546.65 feet;
2. North 10°45'00" East 847.57 feet;
3. North 00003'33TM East 750.00 feet to the northwest comer of said Islandwalk Phase Four and
the POINT OF BEGINNING of the parcel herein described.
Phase Four containing 116.97 acres more or less.
Parcel Less & Excepted containing 26.19 acres more or less.
Parcel Described containing 90.78 net acres more or less.
Subject to easements and restrictions of record.
Bearings are based on the north line of said Islandwaik Phase Four being South 89057'09'' East.
WilsonMiller, Inc.
Marcus L. Be;~nan, Professional Surveyor & Mapper
Florida Registration No. 5086
Not valid unless embossed with the Professional's seal.
W.O.: N0772-FWO-000-GCS00
REF.: 2L-739
DATE: November 1, 2000
N0772-FWO4)O0-4)
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey £ane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 ~
www. wilsontniller, corn
Wi/$onMlller /nc FL LIC ~ LC-CO00170 CA 43
Prepared By/Return to:
William E. Shannon, Esq.
4500 PGA Boulevard, Suite 400
Palm Beach Gardens, Florida 33418
2833100 OR: 2865 PG: 3110
RBCORDBD in OFFICIAL RBCORD~ of ¢OLLIBR COUNTY, FL
07/26/2001 at 0~:38AK DMIGH? I. BROCK, CLERK
RBC FBB
ReLn:
HORSSSHOB DRIVS
SZT 5586
DOC-.70
15.00
.70
UTILITY FACILITIES WARRANTY DEED
THIS INDENTURE made this /~f~ day of ./~t~ ~~ ~z~- 2000,
between ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation
(hereinafter referred to as "Grantor"), and the BOARD OF COUNTY
COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS THE GOVERNING BODY OF
COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER
COUNTY WATER-SEWER DISTRICT, its successors and assigns,
(hereinafter referred to as "Grantee").
W I TNE S S E TH
The Grantor, for and in consideration of the sum of Ten
Dollars ($10.00) and other good and valuable consideration to the
Grantor in hand paid by the Grantee, the receipt whereof is hereby
acknowledged, has granted, bargained and sold, to the Grantee, and
Grantee's heirs, successors and assigns forever, all water and
sewer utility facilities lying within the following described land,
together with appurtenant easement rights for the operation,
installation and maintenance of said facilities, situate, lying and
being in Collier County, Florida, to wit:
See attached Exhibit A
The Grantor does hereby fully warrant the title to the utility
facilities, and will defend the same against the lawful claims of
all persons whomsoever. For the purposes of this conveyance, the
utility facilities conveyed herein shall not be deemed to convey
any of the lands described in Exhibit "A". Grantor and Grantee are
used for singular or plural, as the context requires.
IN WITNESS WHEREOF, Grantor has caused these presents to be
executed the date and year first above written.
OR: 2865 PG: 3111
Witnesses
Name:
ISLAND WALK DEVELOPMENT
COMPANY, a Florida corporation
Harmon D. Smith, V.P.
(CORPORATE SEAL)
State of Florida
County of Palm Beach
The foregoing Utility Facilities ~arrant~ Deed was
acknowledged before me this ,/~Y~-- day of /./~/~~ , 2000
by Harmon D. Smith, Vice President of ISLAND WALK DEVELOPMENT
COMPANY, a Florida corporation.
Notary Public State of Florida
CHRISTINE SCALAMANDRE
Commission #. CC742794
Expires 8 / 31 / 2002
Notary Public
Personally known
OR Produced Identification
Type of Identification Produced
P: \Counsel \CS \ ISLANDWK\wat er- sewer \WarrantyDeedPh3A. wpd
Wil nMiller
New Directions In Planning, Design & Engineering
*** OR: 2865 PG: 3112
Description of part of Islandwalk Phase Four,
Plat Book 34, Pages 35 through 40, Collier County, Florida.
(Islandwalk Phase Four less Ossabaw Way)
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, being
more particularly described as follows;
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, Less
the following described parcel;
BEGINNING at the Northwest comer of said Islandwalk Phase Four;
thence along the north line of said Islandwalk Phase Four; South 89056'27,' East 96.34 feet to the north ¼
comer of Section 33, Township 48 South, Range 26 East, Collier County, Florida;
thence continue along said noah line of Islandwaik Phase Four, South 89057'09'' East 358.62 feet;
thence leaving said line South 05°01 '41" East 721.10 feet;
thence South 12057'58,, West 642.73 feet;
thence South 13°10' 59" East 792.79 feet to a point on the southerly line of said Islandwalk Phase Four;
thence along said line South 89000'00,' West 704.19 feet to a point on the west line of said Islandwalk
Phase Four;
thence along said line in the following Three (3) described courses;
1. Noah 01°00'00'' West 546.65 feet;
2. Noah 10045'00', East 847.57 feet;
3. Noah 00°03'33" East 750.00 feet to the northwest comer of said Islandwalk Phase Four and
the POINT OF BEGINNING of the parcel herein described.
Phase Four containing 116.97 acres more or less.
Parcel Less & Excepted containing 26.19 acres more or less.
Parcel Described containing 90.78 net acres more or less.
Subject to easements and restrictions of record.
Bearings are based on the north line of said Islandwalk Phase Four being South 89057'09', East.
WiisonMiller, Inc.
Marc'us L. Bei~n-aZ ~al ~u~eyor & Mapper
Florida Registration No. 5086
;Notvalid unless embossed with the Professional's seal.
W.O.: N0772-FWO-000-GCS00
REF.: 2L-739
DATE: November 1, 2000
N0772-FWO-000--0
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey Lane, Suite 200 Naples, Florida 34105-8507 941-649-4040 ~ 941-643-5716
www. wilsonmitier, corn
Wd$onMdler, lnc. FL Lic,~ LC-CO00170 CA 43
OWNER'S AFFIDAVIT
STATE OF FLORIDA
COUNTY OF PALM BEACH
BEFORE ME, the undersigned authority, personally appeared
Harmon D. Smith as Vice President of ISLAND WALK DEVELOPMENT
COMPANY, who to me is well known, and having been duly sworn and
under oath, deposes and states:
1. My name is Harmon D. Smith, I am over the age of twenty-
one (21) years, am sui juris, and have personal knowledge of the
facts contained herein.
2. I am the owner of said real property located at Island
Walk, and legally described on Exhibit
3. Ail persons, firms, and corporations, including the
general contractor and all subcontractors, who have furnished
services, labor or materials according to plans and specifications,
or extra items, used in the construction or repair of water and
sewer utility facilities on the real estate hereinafter described,
have been paid in full and that such work has been fully completed
and accepted by the owner.
4. No claims have been made to the Owner by, nor is any suit
now pending on behalf of, any contractor, subcontractor, laborer or
materialman, and further that no chattel mortgages or conditional
bills of sale have been given or are now outstanding as to the
subject utility facilities placed upon or installed in the
aforesaid premises.
5. The utility facilities described herein are not included
in, encumbered by, or subject to any real property mortgage,
chattel mortgage, security agreement, Uniform Commercial Code
financing statement, or any other encumbrance.
6. As and on behalf of the owner of the subject utility
facilities, does for valuable consideration hereby agree and
guarantee, to hold the Board of County Commissioners of Collier
County, Florida, as the governing body of Collier County and as Ex-
Officio the governing Board of the Collier County Water-Sewer
District harmless against any lien, claim or suit by any general
contractor, subcontractor, mechanic or materialman, and against
chattel mortgages, security interests or repair of the subject
utility facilities. Affiant is used as singular or plural, as the
context requires.
The utility facilities referred to herein are located within
the real property described in the attached Exhibit "A".
ISLAND WALK DEVELOPMENT
a Florida corporation
COMPANY,
By: ~ ~ ~7~
Harmon D. Smith, V.P.
AFFIANT
State of Florida
County of Palm Beach
//~ SUBSCRIBED AND SWORN to before me this /~-~/~ d a y o f
~~~/~- , 2000 by Harmon D. Smith, as Vice President of
Island Walk Development Company, a Florida corporation.
Notary Public State of Florida
CHRIS'lINE SCALAMANDRE
Commission :~. CC742794
Expires 8 / 31 / 2002
Notary Public
Personally known ~'f OR Produced Identification
Type of Identification Produced
Prepared By:
William E. Shannon, Esq.
4500 PGA Boulevard, Suite 400
Palm Beach Gardens, Florida 33418
P: \counsel\CS\ I SLANDWK~wat er- sewer\OwnerAf f Ph3A. wpd
Wil nMiller
New Directions In Planning, Design & Engineedng
Description of part of Islandwalk Phase Four,
Plat Book 34, Pages 35 through 40, Collier County, Florida.
(Islandwalk Phase Four less Ossabaw Way)
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, being
more particularly described as follows;
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, Less
the following described parcel;
BEGINNING at the Northwest comer of said Islandwalk Phase Four;
thence along the north line of said Islandwalk Phase Four; South 89°56'27'' East 96.34 feet to the north %
comer of Section 33, Township 48 South, Range 26 East, Collier County, Florida;
thence continue along said north line of Islandwalk Phase Four, South 89057'09" East 358.62 feet;
thence leaving said line South 05°01 '41" East 721.10 feet;
thence South 12°57'58" West 642.73 feet;
thence South 13°10'59" East 792.79 feet to a point on the southerly line of said Islandwalk Phase Four;
thence along said line South 89000'00'' West 704.19 feet to a point on the west line of said Islandwalk
Phase Four;
thence along said line in the following Three (3) described courses;
1. North 01°00'00'' West 546.65 feet;
2. North 10°45'00' East 847.57 feet;
3. North 00°03'33" East 750.00 feet to the northwest comer of said Islandwalk Phase Four and
the PO1NT OF BEGINNING of the parcel herein described.
Phase Four containing 116.97 acres more or less.
Parcel Less & Excepted containing 26.19 acres more or less.
Parcel Described containing 90.78 net acres more or less.
Subject to easements and restrictions of record.
Bearings are based on the north line of said Islandwalk Phase Four being South 89°57'09'' East.
WilsonMiller, Inc.
Marc'us L. Berman, Professional Surveyor & Mapper
Florida Registration No. 5086
Not valid unless embossed with the Professional's seal.
W.O.: N0772-FWO-000-GCS00
REF.: 2L-739
DATE: November 1, 2000
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 :~
www. wilsonmiller, corn
Witso[?Mil/er, lnc fL ~lc ,¢ LC-~?O001?O CA 43
ATTORNEY'S AFFIDAVIT
STATE OF FLORIDA
COUNTY OF PALM BEACH
.BEFORE ME, the undersigned authority, personally on this
/~ day of ~/0~'~~ 2000, appeared WILLIAM E. SHANNON,
who to me is well known, and having been sworn and under oath,
deposes and states:
1. My name is WILLIAM E. SHANNON, I am over the age of
twenty-one (21) years, am otherwise sui juris, and have personal
knowledge of the facts contained herein.
2. I am a licensed attorney, Florida Bar #202363 authorized
to practice law and am practicing law in the State of Florida. My
business address is 4500 PGA Boulevard, Suite 400, Palm Beach
Gardens, Florida 33418. My business telephone number is (561)
627-2112. My business mailing address is 4500 PGA Boulevard, Suite
400, Palm Beach Gardens, Florida 33418.
3. This Affidavit is given as an inducement to the Board of
County Commissioners of Collier County, Florida, as the governing
body of Collier County and as Ex-Officio the Governing Board of the
Collier County Water-Sewer District to accept the dedication or
conveyance of water and sewer utility facilities located within or
upon the real property described in the attached Exhibit UA", which
is incorporated herein by referenced, said land being located in
Collier County, Florida.
4. The Affiant has examined record title information to both
the real and personal property referenced in this affidavit,
including but not limited to, information requested from the
Florida Secretary of State relative to any Uniform Commercial Code
financing statements.
5. The record owner of the real and personal property
described herein is Island Walk Development Company, a Florida
corporation, ("Owner") current and active and authorized to do
business within the State of Florida. The Owner acquired record
title to the subject real property by instrument recorded at
Official Records Book 2331, at Page 2134, of the Public Records of
Collier County, Florida (copy attached hereto as Exhibit "B"
incorporated herein by reference). Persons authorized to execute
instruments on behalf of Island Walk Development Company in
conjunction with the conveyance of the subject property include but
are not limited to; William E. Shannon, President; Harmon D. Smith,
Vice President; and Michael D. Rosen, Vice President.
6. Affiant has examined the Articles of Incorporation of the
Owner and the Certificate of Incorporation issued by the Secretary
of State for the State of Florida. The corporation is current and
active within said State and is currently authorized to do business
in the State of Florida. Harmon D. Smith, as Vice President of
Island Walk Development Company, is authorized to execute the
instruments on behalf of Island Walk Development Company, in
conjunction with the conveyance of any interest in the subject real
and personal property.
o
The subject real and personal property are encumbered by:
NONE
except as specifically noted herein, all of the Public Records of
Collier County, Florida.
8. Affiant further states that the information contained in
this Affidavit is true, correct and current as of the date this
Affidavit is given.
FURT~{ER AFFIANT SAYET~ NAUGHT.
DATED this /~day of /~'~/e~ ~__
, 2000.
William E. Shannon
/~ SUBSCRIBED AND SWORN to before me this /~--~ d a y o f
~g?~~ , 2000 by William E. Shannon, who is personally
known to me.
Notary Public State of Florida
CHRISTINE SCALAMANDRE
Commission ~ CC742794
Expires 8 1 31 1 2002
/Notary Public
Notary Printed Name
Prepared By/Return To:
William E. Shannon, Esq.
4500 PGA Boulevard, Suite 400
Palm Beach Gardens, Florida 33418
P:\Counsel\CS\ISLANDWK\water-sewer\attorneyaffPH3A.wpd
WilsonMiller
New Directions In Planning, Design & Engineering
Description of part of Islandwalk Phase Four,
Plat Book 34, Pages 35 through 40, Collier County, Florida.
(Islandwaik Phase Four less Ossabaw Way)
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, being
more particularly described as follows;
All that part of Islandwalk Phase Four, Plat Book 34, Pages 35 through 40, Collier County, Florida, Less
the following described parcel;
BEGINNING at the Northwest comer of said Islandwalk Phase Four;
thence along the north line of said Islandwalk Phase Four; South 89056'27" East 96.34 feet to the north %
comer of Section 33, Township 48 South, Range 26 East, Collier County, Florida;
thence continue along said north line of Islandwalk Phase Four, South 89057'09" East 358.62 feet;
thence leaving said line South 05°01 '41" East 721.10 feet;
thence South 12°57' 58" West 642.73 feet;
thence South l 3°10'59" East 792.79 feet to a point on the southerly line of said Islandwalk Phase Four;
thence along said line South 89°00'00'' West 704.19 feet to a point on the west line of said Islandwalk
Phase Four;
thence along said line in the following Three (3) described courses;
1. North 01°00'00'' West 546.65 feet;
2. North 10045'00" East 847.57 feet;
3. North 00°03'33" East 750.00 feet to the northwest corner of said Islandwalk Phase Four and
the POINT OF BEGINNING of the parcel herein described.
Phase Four containing 116.97 acres more or less.
Parcel Less & Excepted containing 26.19 acres more or less.
Parcel Described containing 90.78 net acres more or less.
Subject to easements and restrictions of record.
Bearings are based on the north line of said Islandwalk Phase Four being South 89°57'09" East.
WilsonMiller, Inc.
Marcus L. Berman, Professional Surveyor & Mapper
Florida Regislratien No. 5086
Not valid unless embossed with the Professional's seal.
W.O.: N0772-FWO-000-GCS00
REF.: 2L-739
DATE: November 1, 2000
Naples Fort Myers Sarasota Bradenton Tampa
3200 Ba/tey Lane, Suite200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716
www. wilsonmiller, cam
~is Instrument Prepared By
.(r.0 ,~t~ and Please Return To:
P'- '~ ~-' /~::')~'!~, ~ JO HN F..STEWART
'-~ - v'\ ~/0~o~-, SHEPPARD, BRETT, STEWART
,¢ ~ & HERSCH, P.A.
uC
2121 West First Sffeet
P. O. Drawer 400
Fort Myers, Florida 33902
2205889 OR: 2331 PG: 2134
RECORDED in OFFICIAL RECORDS of COLLIER COUNTY,
07'/16/97 at ll:29AM DWIGHT E. BROCK, CLERK
CONS 699689§.00
NC FEB 15.00
DOC-.70 48~78.30
HHBPPARD BRBTT BT AL
P O DRAWER 400
FI MYERS FL 33902
Grantee(s) S.S.
THIS WARRANTY DEED, madethis 1,~ ~ dayof ~"",-,..; ~;
1997, between Harvey Bros. Farms, Inc., a Maryland Corpdration /
whose post office address is: 900 N. Logan Blvd.
Naples, Florida 33999
hereinafter called the grantor, to Island Walk Development Company, a Florida Corporation
whose post office address is: 4500 PGA BlVd. Suite 400
Palm Beach Gardens, Florida 33418
hereinafter called the grantee:
(Wherever used herein the terms "grantor" and "grantee" include all the parties to
this instrument and the heirs, legal representatives and assigns of individuals, and
the successors and assigns of corporations)
WlTNESSETH, that the grantor, for and in consideration of the sum of $10.00 and other
valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells,
aliens, remises, releases, conveys and confirms unto the grantee all that certain land situate in
Collier County, State of Florida, viz:
SEE SCHEDULE "A" ATTACHED
Subject to easements, restrictions and reservations of record, if any, and oil, gas and/or
mineral rights set forth in Deed Book 3 0, Page 91 and Deed Book 34, Page 260 of the Public
Records of Collier County, Florida, and taxes for 1997 and subsequent years.
Property Appraiser's Parcel Identification Nun-tber: a portion of Strap #203200005
TOGETHER, with all the tenements, hereditaments and appurtenances thereto
OR: 2331 PG: 2135
TO HAVE AND TO HOLD, the same in fee simple forever.
AND the grantor hereby covenants with sm.'d grant, e.e th~at,the.,g ..ra.n. :t:o,.~r~.!~;.!a,,.wf~_l}y Seivz~d of
said land in fee simple; that the grantor has good right ana tawrut aumonty to sen ana con y
said land, and hereby warrants the title to said land and will defend the same against the lawful
claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes
accruing subsequent to December 31, 1996.
IN WITNESS WltEREOF, the said grantor has signed and sealed these presents the day
and year first above written.
Signed, Sealed and Delivered
in Our Presence:
~Vitn~ss ~i~¢attire
SHERRY L. NORRIS
ame of Witness
Harvey Bros. Farms, Inc., a Maryland
Corporation
Fred R. Harvey, Presid~_)
Printed Name of Witness
STATE OF FLORIDA
COUNTY OF [ftC,-
The foregoing instrument was acknowledged before me this i.d..m`. day of ,
,1997, by FRED R. HARVEY, President of Harvey Bros. Farms, Inc., a
Maryland Corporation who is personally known to me or who has produced
to ~t'v as identification.
(Seal)
t, / , 'l~;,r.-'-'-4 .... '-
'"l~ootary Public(/
Printed Notary Signature
J -- --II,
PI. ANN S,
SCHEDULE "A"
~ I. ! 1: '..:' (: y(~'l~. 5::, " lAGERS
Description of part of Section 33,
Township 48 South, Range 26 East, Collier County, Florida.
(173.11 +/- Acre Parcel)
Ail that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly
described as follows;
COMMENCING at the southwest comer of said Section 33;
thence along the west line of said Section 33, North 01023'36'' West 170.13 feet to a point on the north right of
way line of Vanderbilt Beach Road (C.IC 862) and the POINT OF BEGINNING of the parcel herein described;
thence continue along said west line North 01023'36'' West 2587.71 feet;
thence leaving said west line South 89007'32" East 2914.97 feet;
thence South 00046'57" West 1404.85 feet; ,
thence South 06o30'53" East 444.52 feet;
thence South 03o07'54'' West 277.90 feet;
thence southerly, southeasterly and easterly, 461.18 feet along the arc of a circular curve concave
northeasterly, having a radius 286.50 feet, through a central angle of 92013'48" and being subtended by a
chord which bears South 42°59'01" East 412.98 feet;
thence South 89°05'55" East 38.62 feet;
thence South 47°46'33" East 114.31 feet;
thence South 00o54'05" West 90.00 feet to a point on the north right of way line of Vanderbilt Beach Road
(C.R. 862);
thence along said line North 89°05'55" West 620.01 feet;
thence continue along said line North 89o06'26'' West 1322.86 feet;
thence continue North 89006'49'' West 1328.72 feet to a point on the west line of said Section 33 and the
POINT OF BEGINNRqG of the parcel herein described.
Containing 173.11 acres more or less.
Subject Co easements and restrictions of record.
Beaxifigs are assumed and based,on the west line of said Section 33 being North 01°23'36'' West.
WIDSON, MI_[ J.ER, BARTON & P~ iNC.
Fl~d~Registrafi0n No. 3516 C,/Q/--
Not valid Unless embossed with the Professional's seal.
W.O.: N-0772-011-00 I-PSCAL
REF.: 4L-1401
DATE: April 16, 1997
Revised May 2, 1997
Revised May 16, 1997
Revised June 4, 1997
Revised June 13, 1997
6/I 3/97~07720001.mlb
WILSON, MILLEI~., B/',I('FON ,~ PEEK, INC.
3200 Bailey l.nne, Suite 200, Nnplcs, Florida .34105-8507 ' Ph 941-649-4040 Fx 941-643-5716
~VcI~ Site: ww~'.wilsoumillcr.com E-mail: nnplcs~wilsonmillcr.co*n
00 ,¥0 This Instrument Prepared By
~%,v ,~,oand Please Return To:
qq ?' JOHN F. STEWART
SHEPPARD, BRETT, STEWART
& HERSCH, P.A.
2121 West First Street
P. O. Drawer 400
Fort Myers, Florida 33902
23 i 54 OR: 2441 PG: 2776
RECORDgD in OFFICIAL RECORDS of COLLIER COUNTY, FL
07/I~/98 at 0~:23PM DWIGHT E. BROCK, CLERK
Retn:
HHBPPARD BRHT BT AL
P 0 DRAWBR 400
FY MYBRS FL 33902
CONS 7612050,00
RBC HB 15.00
DOC-.70 53281,70
Grantee(s) S.S. #65-0663645
THIS WARRANTY DEED, made this c~O~ day of
1998, between Harvey Bros. Farms, Inc., a Maryland corporation
whose post office address is: 7373 Vanderbilt Beach Road ExtenSion
Naples, Florida 34119
hereinafter called the grantor, to Island Walk Development Company, a Florida corporation
whose post office address is: 4500 PGA Blvd. Suite 400
Palm Beach GardenS, Florida 33418
hereinafter called the grantee:
(Wherever used herein the terms "grantor" and "grantee" include all the parties to
this instrument 'and the heirs, legal representatives and assigns of individuals, and
the successors and assigns of corporationS)
WlTNESSETH, that the grantor, for and in consideration of the sum of $10.00 and other
valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells,
aliens, remises, releases, conveys and confirms unto the grantee all that certain land situate in
Collier County, State of Florida, viz:
SEE SCHEDULE "A" ATTACHED
Subject to easements, restrictions and reservations of record, if any, and oil, gas and/or
mineral rights set forth in Deed Book 30, Page 91 and Deed Book 34, Page 260 of the Public
Records of Collier County, Florida, and taxes for 1998 and subsequent years.
Property Appraiser's Parcel Identification Number: a portion of Strap #00203200005
TOGETHER, with all the tenements, hereditaments and appurtenances thereto
belonging or in anywise appertaining.
PAGE . . PAGES
Signed, Sealed and Delivered
TO HAVE AND TO HOLD, the same in fee simple forever.
AND the grantor hereby covenants with said grantee that the grantor is lawfully seized of
said land in fee simple; that the grantor has good right and lawful authority to sell and convey
said land, and hereby warrants the title to said land and will defend the same against the lawful
claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes
accruing subsequent to December 31, 1997.
IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day
and year first above written.
Harvey Bros. Farms, Inc., a Maryland
corporation
Printed ame of Witness
e/
~ ~' John F. Stevc0rt
Printed Name of Wimess
Fred R. Harvey, PreSident
STATE OF FLORIDA
COUNTY OF ~
The foregoing instnm~ent was acknowledged before me this ~_ day of
~"~cc/ ,1998, by FRED R. HARVEY, President of Harvey Bros. Farms, Inc., a.,
Marylanc~ corporation who is personally known to me .or who has produced
t,3/A as identification.
Notary Public l~
(Seal)
SHERRY L, NORRIS
Printed Notary Signature
PAGE
O
COLLIER COUNTY GOVERNMENT
COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DMSION
ENGINEERING REVIEW SECTION
January 22, 2001
PLANNING SERVICES DEPARTMENT
2800 NORTH HORSESHOE DRIVE
NAPLES, FL 34104
Mr. Scot Morrison, E.I.
WilsonMiller
3200 Bailey Lane
Naples, FL. 34105
Re: Island Walk Phase 4B
Dear Scot:
This is to inform you that the above referenced project has been
granted preliminary approval by Engineering Review in compliance
with Collier County Land Development Code, Section 3.2.6.5.2.
All water and sewer facilities approved and accepted and required
to be maintained by Collier County shall be conveyed to the
County pursuant to the provisions set forth in Collier County
Ordinance No. 97-17, as amended.
You are reminded that it is your responsibility to petition the
Development Services Director for final approval of the
improvements upon the expiration of the minimum one (1) year
maintenance period. After satisfactory completion of all final
inspections, the Board of County Commissioners shall adopt a
resolution giving final approval of the'required improvements,
acknowledging the dedication(s) of the final subdivision plat and
establishing County responsibility for maintenance of the
required improvements if it is the Board's desire to accept and
maintain the facilities.
If you should have any questions or if we may be of assistance,
please advise.
Very truly youls,
Senior Engineer
cc: Daryl Hughes, Engineer II
Shirley Nix, Engineering Technician
PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us
COLLIER COUNTY GOVERNMENT
COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION
ENGINEERING REVIEW SECTION
March 20, 2001
PLANNING SERVICES DEPARTMENT
2800 NORTH HORSESHOE DRIVE
NAPLES, FL 34104
Scott Morrison
Wilson, Miller, Barton & Peek, Inc.
3200 Bailey Lane, #200
Naples, FL 34105
Re: Island Walk, Phase 4-B
Dear Mr. Mordson:
This is to inform you that the above referenced project has been granted preliminary approval by
Engineering Review on August 15, 2000 in compliance with Collier County Land Development
Code, Section 3. All water and/or sewer facilities approved, accepted and required to be
maintained by Collier County shall be conveyed to the County pursuant to the provisions set
forth in Collier County Ordinance No. 97-17, as amended.
You are reminded that it is your responsibility to petition the Development Services Director for
final approval of the improvements upon the expiration of the minimum one (1) year
maintenance period. After satisfactory completion of all final inspections., the Board of County
Commissioners shall grant final approval of the required improvements establishing County
responsibility for maintenance of the required improvements if it is the Board's desire to accept
and maintain the facilities.
If you should have any questions or if we may be of assistance, please advise.
Very tru~l~, yours,
Shirley Nix
Engineering Technician II
CCi
Joe Cheatham, Wastewater Director
Paul Mattausch, Water Director
Lisa Taylor, Public Works
John Houldsworth, Engineering Review
PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us
WilspnMiller
New Directions In Planning, Design & Engineering
November 27, 2000
Mr. Thomas Kuck, P.E.
Project Plan Review
Collier County Development Services Center
2800 North Horseshoe Ddve
Naples, FL 34104
SUBJECT: IslandWalk Phase 4-B
Utility Dedication
Engineer's Payment Confirmation
Collier County Conveyance Document Checklist, Legal Document Item 16
Dear Mr. Kuck:
Wilson Miller confirms receiving payment for our services to date on the subject project. As of this
date, no monies are outstanding from the owner/client.
Sincerely,
WILSONMILLER, INC.
Steve Means, P.E.
Project Manager
12/4/(:~87780 Ver: 01T-SMORRISO
#43
N 0772~)24~00-ECOR- 2512~
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716
www. wilsonmiller, corn
WdsonMiller, lnc. FL L/c# LC-CO001?O
WilsOnMiller
New Directions In Planning, Design & Engineering
November 27, 2000
Ms. Shirley Nix
Collier County Engineering Review Services
2800 North Horseshoe Drive
Naples, FL 34104
SUBJECT: IslandWalk Phase 4-B
Utility Testing Results
Dear Ms. Nix:
The following attached tests for the subject project are in our professional judgment and to the
best of our knowledge and belief representative of actual field conditions on the date performed:
1. 8" Watermain pressure test, dated 10/4/00;
2. Inflow/Infiltration Test, dated 11/30/00;
3. 8" Sewer Forcemain pressure test, dated 11/2/00.
If you should have any questions, please do not hesitate to contact our office.
Sincerely,
WILSONMILLER, INC.
Steve Means, P.E.
Project Manager
Enclosures
Engineer's Sig,nature and Seal
12/4/0087780 Ver: OI!-SMORRISO
CA #43
N0772q324 ~OO- ECOR- 25126
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey Lane, Suite 200 Nap/es, Florida 34105-8507 941-649-4040 ~ 941-643-5716
www. wilsonmiller, com
WilsonMiller, lnc FL Lic.# LC C000170
HYDROSTATZC TEST REPORT
Type of Main:
PIN:
Plan File:
Supt.:
Field Rep.: ~,~,,ry'~.~m--- ~..~
Date of Test:
The computed allowable leakage for the test section is (calculations attached)
~, -~ Gal. Hr.
The maintained test pressure for the test duration was
psi.
The measured leakage during the test was
gallons.
The duration of the test was
The measured leakage was
gallons per hour.
The method of measurement was: Meter:
Calibrated Drum
The hydrostatic test for this section meets ~" does not meet
allowable leakage.
the
WilsonMiller, :[nc.
Field Representative
Date:
~60~22 V~:. 011~l&x~beC
The
HYDROSTATTC TEST REPORT
Type of Main: ~'// ~d~-cC ~,~, iA}
PIN:
Plan File:
Field Rep.:.
Date of Test:
_.
computed allowable leakage for the test section is (calculations attached)
r~-' ~ 0 Gal. Hr.
The maintained test pressure for the test duration 'was
psi.
The measured leakage during the test was
gallons.
The duration of the test was
The measured leakage was-.
gallons per hour.
The method of measurement was: Meter:
Calibrated Drum:
The hydrostatic test for this section meets
allowable leakage.
does not meet
the
WilsonMiller, [nc.
leld RepresentativJ
Date:
Department of
...... Environmental Protecti
~~~--~"----~-~ - South District
Jeb Bush P.O. Box 2549
Governor Fo~ Myers, Florida 33902-2549
David B. Struhs
Secretary
Michael D. Rosen, Vice President
Sunco Building Corporation
6005 Vanderbilt Beach Road
Naples, FL 34119
Re:
January l7,2001
Collier Coun _ty - PW
IslandWalk Phase 4
Final Completion
(Collier County Regional WTP)
166174-001-DSGP
Southwest Coast EMA
EOEIVED
Dear Mr. Rosen:
This acknowledges receipt of certification that the subject water distribution system extension has
been completed in accordance with the plans and related materials permitted by this agency under
Permit Number 166174-001-DSGP dated March 10, 2000.
Based on this certification and satisfactory bacteriological results, we are approving these
facilities for service. Your continued cooperation in our water supply program is appreciated.
O. James Oni
Professional Engineer
Water Facilities
OJO/MFJ
cc: Steve Means, P.E.
Thomas E. Kuck, P.E.
"More Protection, Less Process"
Printed on recycled paper.
F OLDtzR #
DOMESTIC WASTEWATER COLLECTION/TRANSMISSIONSYST~S
CERTIFICATION OF COMPLETION OF CONSTRUCTION
Florida Department of Env~~'Otecti~n
Twin Towers Office Bldg., 2600 Blair Stone R~~'llhOC~,k~i~ 32399-240o~_
INSTRUCTIONS: This form is to be completed and submitted to the Department, prior to placing the system into operation. A
collection/transmission system should not be placed into operation without prior Department approval. All information is to be typed or
printed in ink and all blanks must be filled.
Construction Permit No.: 50581-202-DWC/CM
Dated: 3/1/00
Name of Project: - IslandWalk Phase Four-B
Name of Owner: Sunco Buildin~ Corp. c/o Michael D. Rosen
Name of design engineer and Florida registration number (if different fi.om engineer signing certification):
Stephen A. Means, P.E. FL#36844
Date(s) connection to existing system or treatment plant: March 2001
Treatment plant serving project
Name: North Naples Regional WWTP
County: Collier City: N/A
DEP Identification Number (also known as WAFR or GMS Identification Number):
Substantial deviations fi.om the approved plans and specifications
N/A
FLS014139
'required):
~9555 Vet: OI!-SMORRISO
FINAL RELEASE OF LIEN
KNOW ALL MEN BY THESE PRESENTS:
That the undersigned, for and in consideration of the payment of the sum ofTEN
DOLLARS (10.00) paid by, DIVOSTA & COMPANY, receipt of which is hereby
acknowledged, hereby releases and quit claims to the said, DIVOSTA & COMPANY Owner,
its successors and assigns, all liens, lien rights, claims or demands of any kind whatsoever, which
the undersigned now has or might have against the building on premises legally described as:
ISLAND WALK PHASE-4B
A PORTION OF LAND LYING IN
SECTION 33, TOWNSHIP 48S, RANGE 26E
COLLIER COUNTY, FLORIDA
on account of labor performed and/or material furnished for the construction of any improvements
thereon. That all labor and materials used by the undersigned in the erection of said improvemems
have been fully paid.
IN WITNESS WHEREOF, I have hereunto set my hand and sepl/~J~s 28th day of
November, 2000 ,// ~ - --
WITNESSES: _ FLORIDA STATEJJI~DERGROUND, INC.
ent
STATE OF FLORIDA
COUNTY OF COLLIER
Thomas P~McKimm, on b~a~ofthe
take a~l oa~?/ /~
The foregoing instrument was acknowledged before me this 28th day of November, 2000
company who is personally known to me and did not
My Commission Expires:
CATHYE VANKERSCHAEVER
Notary Public ~ State of Florida
My comm. expires Sept 19, 2001
Comm. No. CC670403
State of Florida
Dep~rtmnt of Health
Office.~ Lab~ratory Services
dltCksonvi[te, Miami, Pensacola
Tmnpa, West Palm Beach
DRINKING WATER
BACTERIOLOGICAL ANALYSIS
LAB USE ONLY
SYSTEM NAME:
ADDRESS:
COLLECTOR:
Press hard, (5) copies
SAMPLE SITE (Locality or Subdivision):
DATE AND TIME COLLECTED:
TYPE OF SUPPLY(Circle one):
TYPE OF SAMPLE(Circle one):
SYSTEM I.D. NO: SYSTEM PHONE #:
COUNTY: DISTRICT:
COLLECTOR PHONE #:
Communj_ty water system Noncommunity water system Nontransient - noncommunity water system
Private well Swimming pool Bottled water Limited Use system
Compliance Repeat Replacement Main clearance Well survey Other
(Check Box) [ ] Check here if payment made
[ ] Distribution to county public health uni
[ ] Raw
TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB
ANALYSIS METH~: ~Fi MTF MMO-MUG PA
COLL. SAMPLE POINT cl NON CONFIRM CONFIRM
NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER
* Results in this column are presumptive. Total coliform and fecal coliform or E. coli :onfirmation will follow in ours.
p - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid
A - Co[iforms are absent TNTC - Too numerous to count
INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER
NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT
REVIEWING OFFICIAL:
TITLE:
( )
( ) SATISFACTORY
( ) INCOMPLETE COLLECTION INFORMATION
( ) REPEAT SAMPLES
( ) REPLACEMENT SAMPLES
State of Florida
Department of Health
O~fic~[f Laboratory Services
~j~ks~lv~ile, Miami, Pensacola
Tampa, Uest Palm Beach
DRINKING WATER
BACTERIOLOGICAL ANALYSIS
FOR LAB USE ONLY
Press hard, (5) copies
SYSTEM NAME:
ADDRESS:
COLLECTOR:
SAMPLE SITE (Locality or Subdivision):
DATE AND TINE COLLECTED:
TYPE OF SUPPLY(Circle one):
TYPE OF SAMPLE(Circle one):
SYSTEM I.D. NO: SYSTEM PHONE #:
COUNTY: DISTRICT:
COLLECTOR PHONE #:
Community water system Noncommunity water system Nontransient - noncommunity water system
Private well Swimming pool Bottled water Limited Use system
Compliance Repeat Replacement Main clearance We[[ survey Other
(Check Box)
[ ] Distribution [ ] Check here if payment made
[ ] Raw to county public health uni
TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB
ANALYSIS METHOD: MF MTF MMO-M~G PA
COLL. SAMPLE POINT Cl NON CONFIRM CONFIRM
NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER
i
* Results in this column are presumptive. Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours.
P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid
A - Coliforms are absent TNTC - Too numerous to count
INVOICE ADDRESS (if different than address below):
INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER
NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT
REVIEWING OFFICIAL
TITLE:
( )
( ) SATISFACTORY
( ) INCOMPLETE COLLECTION INFORMATION
( ) REPEAT SAMPLES
( ) REPLACEMENT SAMPLES
S~ate of FLorid~
~ * O~rtmnt of Health
Uffice of Lab~ratory Services
Jacksonville° N~mi, Pensacola
Tampa, West Palm Beach
DRINKING WATER
BACTERIOLOGICAL ANALYSIS
FOR LAB USE ONLY
SYSTEM NAME:
ADDRESS:
COLLECTOR:
Press hard, (5) copies
SYSTEM I.D. NO:
COUNTY:
SYSTEM PHONE #:
DISTRICT:
COLLECTOR PHONE #:
DATE AND TIME COLLECTED:
TYPE OF SUPPLY(Circle one):
SAMPLE SITE (Locality or Subdivision):
TYPE OF SAMPLE(Circle one):
Community water system Noncommunity water system
Private well Swimming pool Bottled water
Repeat Replacement
Compliance
(Check Box)
[ ] Distribution
[ ] Raw
TO BE COMPLETED BY COLLECTOR OF SAMPLE
COLL. SAMPLE POINT Cl
NO. (Specific Address) RES'D pH
* Results in this column are presumptive.
p - Coliforms are present
A - Coliforms are absent
Nontransient - noncommunity water system Limited Use system
Main clearance Well survey Other
[ ] Check here if payment made
to county public health unit
TO BE COMPLETED BY LAB
ANALYSIS METHOD: MF MTF MMO-MUG
PA
NON
COLIFORM
*TOTAL
CONFIRM
TOTAL
CONFIRM
FECAL E. COLI
SAMPLE NUMBER
Total coliform and fecal coliform or E. cell confirmation will follow in 24-48 hours.
C - Confluent growth TA - Turbid, Absence of gas or acid
TNTC - Too numerous to count
INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY, PROGRAM REVIEWER
NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT
REVIEWING OFFICIAL:
TITLE:
( )
( ) SATISFACTORY
( ) INCOMPLETE COLLECTION INFORMATION
( ) REPEAT SAMPLES
( ) REPLACEMENT SAMPLES
State of Florida
, *~l)~partment of Health
~ Office of Laboratory Services
Jacksonville, Miami, Pensacola
Taal~a, West Pate Beach
DRINKING WATER
BACTERIOLOGICAL ANALYSIS
FOR LAB USE ONLY
Press hard, (5) copies
SYSTEM NAME:
ADDRESS:
COLLECTOR:
SA~4PLE SiTE (Locality or Subdivision):
DATE AND TIME COLLECTED:
TYPE OF SUPPLY(Circle one):
TYPE OF SAMPLE(Circle one):
SYSTEM I.D. NO: SYSTEM PHONE #:
COUNTY: DISTRICT:
COLLECTOR PHONE #:
Community water system .Noncommunity water system Nontransient - noncommunity water system
Private we[[ Swimming pool Bottled water Limited Use system
Compliance Repeat Replacement Main clearance Well survey Other
(Check Box)
[ ] Distribution [ ] Check here if payment made
[ ] Raw to county public heaLth unit
TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB
ANALYSIS METHOD: MF MTF MMO-MUG PA
COLL. SAMPLE POINT CL NON CONFIRM CONFIRM
NO. (Specific Address) RESID pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER
Results in this column are presumptive. Total coliform and fecal coliform or E. coLi confirmatior will follow in 24-48 hours.
P - Co[iforms are present C - Confluent growth TA - Turbid, Absence of gas or acid
A - CoLiforms are absent TNTC - Too numerous to count
INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY, PROGRAM REVIEWER
NAM AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT
REVIEWING OFFICIAL:
TITLE:
( )
( ) SATISFACTORY
( ) INCOMPLETE COLLECTION INFORMATION
( ) REPEAT SAMPLES
( ) REPLACEMENT SAMPLES
FLORIDA STATE UNDERGROUND, INC.
CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS
SYSTEM NAME: ISLAND WALK PHASE 4B
DATE: November 22, 2000
THIS IS A: WATER SYSTEM X SEWER SYSTEM
ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST
AIR RELEASE VALVE 10 EA 1,300.00 13,000.00
PVC C-900 CL 150 6" 6619 LF 8.55 56, 592.45
PVC C-900 CL200 6" 252 LF 10.10 2,545.20
PVC C-900 CL150 8" 3515 LF 12.18 42,812.70
PVC C-900 CL200 8" 160 LF 13.55 2,168.00
DOUBLE SERVICE 1" 94 EA 392.00 36,848.00
SINGLE SERVICE 3/4" 59 EA 270.00 15,930.00
FIRE HYDRANT 19 EA 1,805.00 34,295.00
GATE VALVE W/BOX 6" 8 EA 460.00 3,680.00
GATE VALVE W/BOX 8" 4 EA 630.00 2,520.00
PBSP 4 EA 795.00 3,180.00
TOTAL 213,571.35
I DO HEREBY CERTIFY THE ABOFE DESCRIBED LIST OFMATERIALS, QUANTITIES OF MATERIALS, KINDS OF
MATERIALS, INCLUDING INSTALLA TION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TR UE AND
ACCURATE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS
CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD
DRA WINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN, AS OF THIS DATE.
PERSONALLY KNOWN, SWORN TO CERTIFYING:
& SUBSCRIBED BEFORE ME THIS -..~_~___~
,'/"~ -'~/--; ~// ?' i FLORIDA ~ UNDERGROUND, INC.
~.~'d'_~f~ f ~~a I (SEAL)
(NTTA~a~I~~]~Stf~rl°rida l
/ ay ~o~. ~×pi~ scp~ ~, ~oo~ i
| Comm. 40. CCC~040~
FLORIDA STATE UNDERGROUND, INC.
CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS
SYSTEM NAME: ISLAND WALK PHASE 4B
DATE: November 22, 2000
THIS IS A: WATER SYSTEM SEWER SYSTEM X
ITEM DESCRIPTION SIZE QUANTIFY UNIT COST TOTAL COST
p, vc SDR26 0-6 8" 4048 LF 14.45 58,493.60
PVC SDR26 6-8 8" 1680 LF 21.82 36,657.60
PVC SDR26 8-10 8" 1680 LF 27.60 46,368.00
PVC SDR26 10-12 8" 493 LF 67.80 33,425.40
PVC SDR26 t2-I4 8" I80 LF 87.10 15,678.00
MANHOLE 0-6 19 EA 1,141.35 21,685.65
MANHOLE 6-8 11 EA t~450.15 15,951.65
MANHOLE 8-10 6 EA ., 1,619.00 9,714.00
MANHOLE 10-12 2 EA 1,980.00 3z960.00
MANHOLE 12-14 3 EA 2,38Z00 7,146~00
SINGLE SERVICE 29 EA 365.00 10,585.00
DOUBLE SERVICE 106 EA 400.00 42,400:00
PVC F.M. C-900 CL100 8N 4265 LF 9.45 40,304.25
PLrMP STATION #5 & 6 2 EA 58,300.00 116,600.00
PUMP STATION 87 I EA 63,640.00 63,640.00
PLUG VALVE 8'° 3 EA 1,041.75 3,125.25
;.._...~; ...... ; .................... TOTAL 525,734.40
I DO HEREBY CERII/qr THE ABOVE DESCRIBED LIST OFAJA TERIALS, QUANTITIES OFMATERIALS, KINDS OF
MA TERIALS, INCLUDING INSTALLA TION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND
ACCURATE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEAJENTS OF (B~R FROM) THIS
CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CJi~IFIED RECORD
DRAWINGS OF THIS SYSTF2vlAS DESCRIBED BY NAME SHOWN, AS OF THIS DATE.//
PERSONALLY KNOWN, SWORN TO CERTIFYING:
~.~I~ kY ~2000 TI~JI2/MA'~"I~~VlM, PRESIDENT
' FL
Z4.~ Z/ ~ /'/ ORIDA ST4~ UNDERGROUND, INC.
~;~t~7~ / z~o,~/~/~ (SEAL)
~' Nowxy Publie- Stat~ of Florida
My corem, enptr~a S~I0t 19, 2001
Comm, No, CC670403
Wilsp. nMiller
New Directions in Planning, Design & Engineering
November27,2000
Mr. Thomas Kuck, P.E.
Project Plan Review
Collier County Development Services Center
2800 North Horseshoe Drive
Naples, FL 34104
SUBJECT:
IslandWalk Phase 4-B
Utility Dedication Engineer's Certification
Dear Mr. Kuck:
Please accept this letter as representation that in our professional judgment and to the best of our
knowledge and belief the potable water distribution and sanitary sewer collection systems as listed
below for IslandWalk Phase 4-B have been completed in substantial accordance with the plans
(WM FILE NO. D-0772-22) and specifications approved by Collier County Engineering Review
Services.
Furthermore, to the best of our knowledge and belief the subject water and sewer facilities have
been constructed by the contractor within the public right-of-way and/or dedicated easements.
Please contact me should you have any questions regarding this matter.
Sincerely,
WlLSONMILLER, INC.
Steve Means, P.E.
Project Manager
Engineer's signature and seal
Naples Fort Myers Sarasota Bradenton Tampa
3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716
www. wil$onmil/er, cum
12/4/00-87780 Ver: Ol!-SMORRISO
CA#43 WJ/sonMJ/ler, lnc. -- FL tic# LC-CO00170
N0772~}244~00- £COR -25126
November 22, 2000
Board of Collier County Commissioners
3301 Tamiami Trail East
Naples, FL. 34112
RE: WATER DISTRIBUTION SYSTEM
"ISLAND WALK PHASE4B"
Section 33, Township 48S, Range 26E,
Island Walk Subdivision
AS RECORDED N.O.C. 2599933, OR: 2646,PG: 1647 & 0648
Collier County, Florida.
Commissioners:
This letter is to certify the completion of the WATER DISTRIBUTION SYSTEM
located within the above referenced property. Florida State Underground, Inc. furnishes
at least a one (1) year guarantee of material and workmanship on the system, upon
acceptance by the Colli~unty Board of Commissioners.
//
S ,ly,
President
TPM/mkt
73 COMMERICAL BOULEVARD * NAPLES, FLORIDA 34104 * 643-6449 * FAX: 643-6891
November 22, 2000
Board of Collier County Commissioners
3301 Tamiami Trail East
Naples, FL. 34112
RE: SEWER DISTRIBUTION SYSTEM
"ISLAND WALK PHASE-4B"
Section 33, Township 48S, Range 26E,
Island Walk Subdivision
AS RECORDED N.O.C. 2599933, OR: 2646,PG: 1647 & 0648
Collier County, Florida.
Commissioners:
This letter is to certify the completion of the SEWER DISTRIBUTION SYSTEM
located within the above referenced property. Florida State Underground, Inc. furnishes
at least a one (1) year guarantee of material and workmanship on the system, upon
acceptance by the Collier County Board of Commissioners.
~_~~s P.~Kimm ~ President
TPM/mkt
73 COMMERICAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891
Official Receipt - Collier County Board of County Commissioners
CDPR1103 - Official Receipt
I Trans Number i Date l Post Date
1239829 12/28/2000 10:05:12 AM 12/28/2000
FLORIDA STATE UNDERGROUND, INC.
GUADELOUPE WAY/ISLAND WALK
tPayment Slip Nbr
u~~ 7-~___
Payor · FL STATE UNDERGROUND INC
Fee Code_~D~scription
t42~Y1~ -r c-o~-~-INvoicEs
Fee Information
._ ~GL Account
[~0800000011510000000
Total
Amount I Waived
_ $3_92.90~
~P_ayment Code ~ Account/Check Number
~C-H~--- ~ 1419
Payments
Amount
Memo:
Total Cash
Total Non-Cash
Total Paid
J $392.90~
_ _ $o~o-O~
__~ $39~.90~
$392.90~
DOR1240, W/O # 034035, Unrestrained joint separation during tie-in of new line by contractor. This joint installed
by the same contractor, valved down. Bacteriological testing after flush.
Cashier/location: SORIANO V / 3
User: AVILES L -
Collier County Board of County Commissioners
CD-Plus for Windows 95/NT
Printed:01/23/2001 9:55:39 AM
Official Receipt - Collier County Board of County Commissioners
CDPR1103 - Official Receipt
Trans Number Date Post Date Payment Slip Nbr
250914 03/06/2001 12:54:52 PM 03/06/2001 UT 82627
FLORIDA STATE UNDERGROUND
ISLAND WALK/ISLAND WALK PHASE 4 B
Payor' FLORIDA STAT UNGROUND
Fee Information
lFee Code
42CYIN
Description
COUNTY INVOICES
GL Account
40800000011510000000
Total
Amount Waived
$1161.60
$1161.60
Payments
Payment Code Account/Check Number AmountI
CHECK 1772 $1161.60 i
Memo:
DOR# 1301
$1161.60
Florida State Underground
73 Commercial Blvd
Naples, FL 34104
Total Cash
Total Non-Cash
Total Paid
$0.00 t
$1161.60
$1161.601
Cashier/location: FOGLE C / 3
User: PITERA D
Collier County Board of County Commissioners
CD-Plus for Windows 95/NT
Printed:03/12/2001 8:22:45 AM
GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT
4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-6901
(941) 455-2121 · FAX (941) 455-7917
March 15, 2001
Mr. Richard Regan
Divosta Building Corporation
6005 Vanderbilt Beach Road
Naples, Florida 34119
Dear Mr. Regan
Subject: Hydrant Flow Tests/Islandwalk
On March 14, 2001, the Golden Gate Fire Control & Rescue District did a flow test on eighteen- (18) fire
hydrants at Islandwalk. The results are:
1. Hydrant 33482681 - 4406 Prescott Lane
76 Static PSI
38 Residual PSI
27 Pitot Flow PSI
1075 at 20 PSI Residual
2. Hydrant 33482682 - Hvd. #2 - Prescott Lane
76 Static PSI
38 Residual PSI
24 Pitot Flow PSI
1013 GPM at 20 PSI Residual
3. Hydrant 33482683 - Hyd. #3 - Prescott Lane
76 Static PSI
38 Residual PSI
25 Pitot Flow PSI
1034 GPM at 20 PSI Residual
4. Hydrant 33482684 - Hyd #4 - Prescott Lane
76 Static PSI
38 Residual PSI
22 Pitot Flow PSI
970 GPM at 20 PSI Residual
5. Hydrant 33482685 - Islandwalk Circle & Queen Elizabeth Lane
76 Static PSI
38 Residual PSI
32 Pitot Flow PSI
1170 GPM at 20 PSI Residual
Mr. Richard Regan
Divosta Building Corporation
Page 2
March 15, 2001
6. Hydrant 33482686 - Hyd. #2 - Queen Elizabeth Lane
76 Static PSI
38 Residual PSI
28 Pitot Flow PSI
1095 GPM at 20 PSI Residual
7. Hydrant 33482687 - Hyd. #3 - Queen Elizabeth Lane
76 Static PSI
28 Residual PSI
20 Pitot Flow PSI
815 GPM at 20 PSI Residual
8. Hydrant 33482688 - Islandwalk Circle & Redonda Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
9. Hydrant 33482689 - Hyd #2 - Redonda Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
10. Hydrant 33482690 - Hyd. #3 - Redonda Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
11. Hydrant 33482691 - Hyd. #4 - Redonda Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
12. Hydrant 33482692 - Hyd. #1 - Saint George Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
13. Hydrant 33482693 - Hyd. #2 - Saint George Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
Mr. Richard Regan
Divosta Building Corporation
Page 3
March 15, 2001
14. Hydrant 33482694 - Hyd. #1 - Tabago Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
15. Hydrant 33482695 -Hyd. #2 -Tabago Lane
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
16. Hydrant 33482696 - Islandwalk Circle & Trinidad Wag
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
17. Hydrant 33482697 - Hyd. #2 - Trinidad Way
76 Static PSI
38 Residual PSI
30 Pitot Flow PSI
1133 GPM at 20 PSI Residual
18. Hydrant 33482698 -Hyd. #3 -Trinidad Way
76 Static PSI
38 Residual PSI
20 Pitot Flow PSI
925 GPM at 20 PSI Residual
Before completion of the project, the hydrants need to be painted OSHA safety yellow. The caps on
hydrants #33482684, #33482687, and #33482698 need to be painted OSHA safety orange. The rest of the
hydrant caps need to be painted OSHA safety green. Also, blue road reflectors need to be installed to show
location of all hydrants.
This Fire District does not accept ownership nor does it maintain fire hydrants after their installation.
Total due the Golden Gate Fire District for the eighteen- (18) flow tests is $630.00.
Sincerely,
Donald R. Peterson
Fire Chief
DRP/pm
Enclosures
Golden Gate Fire Department
Hydrant Flow Test By Hydrant
Hydr ID Between "33482681 "And "33482698
,!
33482681 4406 PRESCOTT LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 27 0 872 1075 1175 1268
10 Nelson Corey, J
Min: 872 1075 1175 1268
Subtotal Flow Tests: i
Max: 872 1075 1175 1268
Avg: 872 1075 1175 1268
33482682 HYD #2 PRESCOTT LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 24 0 822 1013 1107 1195
10 Nelson Corey, J
Min: 822 1013 1107 1195
Subtotal Flow Tests: I
Max: 822 1013 1107 1195
Avg: 822 1013 1107 1195
33482683 HYD #3 PRESCOTT LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 25 0 839 1034 1130 1220
10 Nelson Corey, J
Min: 839 1034 1130 1220
Subtotal Flow Tests: i
Max: 839 1034 1130 1220
Avg: 839 1034 1130 1220
33482684 HXD #4 PRESCOTT LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 22 0 787 970 1060 1144
10 Nelson Corey, J
Min: 787 970 1060 1144
Subtotal Flow Tests: I
Max: 787 970 1060 1144
Avg.' 787 970 1060 1144
03/15/2001 07:50
* Scheduled Flow Test
Page 1
Golden Gate Fire Department
Hydrant Flow Test By Hydrant
Hydr ID Between "33482681 "And "33482698
,,
33482685 ISLAND HALK CIR & QUEEN ELIZABETH LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 32 0 949 1170 1279 1380
10 Nelson Corey, J
Min: 949 1170 1279 1380
Subtotal Flow Tests: I
Max: 949 1170 1279 1380
Avg: 949 1170 1279 1380
33482686 HYD #2 QUEEN ELIZABETH LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 28 0 888 1095 1196 1291
10 Nelson Corey, J
Min:
Subtotal Flow Tests: i
Max:
Avg:
888 1095 1196 1291
888 1095 1196 1291
888 1095 1196 1291
33482687 HXD #3 QUEEN ELIZABETH LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 28 20 0 750 815 891 961
10 Nelson Corey, J
Min: 750 815 891
Subtotal Flow Tests: I
Max: 750 815 891
Avg: 750 815 891
961
961
961
33482688 ISLAND WALK CIR & REDONDA LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min: 919 1133 1238 1336
Subtotal Flow Tests: I
Max: 919 1133 1238 1336
Avg: 919 1133 1238 1336
03/15/2001 07:50
* Scheduled Flow Test
Page 2
Golden Gate Fire Department
Hydrant Flow Test By Hydrant
Hydr ID Between "33482681 "And "33482698
,,
33482689 HYD #2 REDONDA LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min .' 919
Subtotal Flow Tests: I
Max: 919
Avg: 919
1133 1238 1336
1133 1238 1336
1133 1238 1336
33482690 HYD #3 REDONDA LN MUELL~R
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min: 919 1133 1238 1336
Subtotal Flow Tests: I
Max: 919 1133 1238 1336
Avg: 919 1133 1238 1336
33482691 HYD #4 REDONDA LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min:
Subtotal Flow Tests: i
Max:
Avg:
919 1133 1238 1336
919 1133 1238 1336
919 1133 1238 1336
33482692 HYD #1 SAINT GEORG~ LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Subtotal Flow Tests: i
Min: 919 1133 1238 1336
Max: 919 1133 1238 1336
Avg: 919 1133 1238 1336
03/15/2001 07:50
* Scheduled Flow Test
Page 3
Golden Gate Fire Department
Hydrant Flow Test By Hydrant
Hydr ID Between "33482681 "And "33482698
33482693 HYD #2 SAINT GEORGE LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30
10 Nelson Corey, J
Min:
Subtotal Flow Tests: I
Max:
Avg:
0 919 1133 1238 1336
919 1133 1238 1336
919 1133 1238 1336
919 1133 1238 1336
33482694 HYD #1 TABAGO LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min: 919 1133 1238 1336
Subtotal Flow Tests: I
Max: 919 1133 1238 1336
Avg: 919 1133 1238 1336
33482695 HXD #2 TABAGO LN MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0 919 1133 1238 1336
10 Nelson Corey, J
Min: 919 1133 1238 1336
Subtotal Flow Tests: i
Max: 919 1133 1238 1336
Avg: 919 1133 1238 1336
33482696 ISLAND WALK CIR & TRINADAD WAY MUELLER
Date Static Residual Pitot Pitot 2 GPM 20 PSI 10 PSI 0 PSI
03/14/2001 76 38 30 0
10 Nelson Corey, J
Min:
Subtotal Flow Tests: i
Max:
Avg:
919 1133 1238 1336
919 1133 1238 1336
919 1133 1238 1336
919 1133 1238 1336
03/15/2001 07:50
* Scheduled Flow Test
Page 4
Feb 26 O1
COLLIER COUNTY CROSS CONNECTION CONTROL
Test And Maintenance Report
Customer I~ I-.~1~ LO 1:~1 I~__~
Street Address O'P t.O srgE~__T__=_'l'g~qP. Mailing Address
Location of Assembly '/'~'/"/~, -- tO, ~', C~_o~O~ ~/e2
Type Of Assembly RP {~ DC [ I PVB [ ]
Fire Line [] Potable
Manufacturer ~ I I, ~1~O~. Model
Test Guage Manufacturer /c//DI~-7'
Gauge Serial No.
Size~
Serial No. I I.___~Z S~
t,4t Ts?
Meter No. 9~_43~104 Date Tested ~~ 0~__
RELIEF VALVE CHECK VALVE #2 PRES. VACUUM BREAK'R.R
[ ] leaked opened at: 4'P--. PSI [ ] leaked air inlet opened at ~PSI
[~lrclosed tight [41~ closed tight did not open [ ]
gauge pressure did not open [ ] gauge pressure check valve:
across check
across check leaked [ ]
valve q' .% PSI valve ~. Z- _ PSI held at PSI
[ ] clcaned only [ ] cleaned only [ ] cleaned only [ ] clcaned only
, replaced: replaced: replaced: replaced:
rubber k/t [ ] rubber kit [ ] rubber 'kit [ ] rubber kit [ ]
CV assembly [ ] RV assembly [ ] CV assembly [ ] CV assembly [ ]
or or or disc, air in [
disc [ ] disc [ ] disc [ ] disc, CV [ ]
o-rings [ ] diaphragm(s) [ ] o-rings [] spring, air [
seat [] seat [ ] seat [] spring, CV [
si>ring [ ] spring [ ] spring [ ] retainer [ ]
stern/guide [ ] guide [ ] stem/guide [] guide []
retainer [ ] o-rings [ ] retainer [ ] o-ring [ ]
lock nuts [ ] other [ ] lock nuts [ ] other [ ]
other [ ] other [ ]
gauge pressure relief valve gauge pressure air inlet PSI
across check opened at across c}xcck --
valve PSI __PSi valve_ _PSI chk. valve PSI
Note: Al/repairs shall be completed within ten (10) days.
Remarks. "01~.5 ~ ..
I hereby certify that this data is accurate and reflects the proper operation and maintenance of the assembly.
Tester ~_,~/o jO~
Cert. No. ~ I O 5~
Date ~/lg /ol____
SANZTARY SEWER SYSTEM
ZN FTLTRAT'rON REPORT
Project:
Date:
Criteria'
*50 gallons per inch of internal pipe diameter per mile per
day including manholes or as required by the
specifications.
An infiltration and/or flow observation was made on the subject project.
The results are as follows:
*gal.
~,,~LF x ~" in. Dia. x 50 day x I
5280 LF in. Dia. 24 hr. x 60 gal.
MI day min.
gal.
min.
From
To
Gallons per Minute
Measured
GPM
Gallons per Minute
Allowable
GPM
Pre pa red by'
Revised 6/99
6/g/99-605113 Vet: (ll~-CHornbac
Oldcastle Precast Ino,
www.oldcastle-precast.com
2140 Pondella Rd. · North Fort Myers, FL 33903-5194
Phone (941) 574-8896
Fax (941) 574-1419
September 12, 2000
Florida State Underground
73 Commercial Blvd.
Naples, FL 34104
Re~
Manhole Coating Certification
Sanitary Sewer System
Collier County
Island Walk Phase 4
Gentlemen:
This letter is to certify the coating on the manholes located at Island Walk Phase 4. Oldcastle Precast, Inc.
certifies that the coating has been applied in a minimum thickness of 18 mils on the exterior surface and a
minimum of 36 mils, in two coats, on the interior surface of the manhole. Oldcastle Precast, Inc. certifies
that the coating is Coal Tar Epoxy C-200, and approved epoxy bituminous sealant.
Sincerely
Michael McDonnell
Regional Sales Manager
MM/dat
md Ui ir': u~p
DEC-- 9--0~ ~9-'2~ ;~
Bsy Electric of Collier County, lac.
DAT~'
P 0,~,
Feb 13 O1 12:03p
~--1~--88 ~ :2~ AM BAY ELECYRIC OF COLLIER
p.3
Bay Electric of Collier County, Inc.
410~ Arnold ~, * N~ ~ ~I~
V(3tTA(~ labor) ~ IN ~,~ AS l~t )~A33ONA~ ~'~C CODE
I
Feb 13 01 12: 03p
I~EC-i ~--OO Be =25 AM ~y I[LI:CT,~IC, OF COLLIER
P.~i~
Bay Electric of Collier County, Inc.
~106 Arnold Aw, · N~I~, FL ~IO~
MANUfACIURTR'S REPRESENTAI'IVE
WATER AN0 WASTE WATER TREATMENT EQUIPMENT
SERVICE DIVISION START-UP REPORT
JOB NAME ISLAND WALK PH 4 LS #5 OPERATOR
LOCATION OF INSTALLATION Naples, FL
CONTRACTORFlorida State Undergroun~ESI~N CONDITIONS: GPM__
PUMP MODEL CP3140 H.P. 15 IMPELLER 481: VOLTAGE 230 PHASE
SERIAL NUMBER ~1 180-0020110 #2 180-0020111
#3
MANUFACTURER OF CONTROL
OVERLOAD HEATER % B-79
ALTERNATOR TESTED YES
COMMENTS:
Collier County
TDH
3
#4
QCI SERIAL ~ 03-00-02
L/A CONNECTED YES GROUND CONNECTED
YES
MEGGER CHECK #1 INF RED INF BLACK INF WHITE
#2 INF RED INF BLACK INF WHITE
#3 RED BLACK WHITE
#4 RED BLACK WHITE
VOLTAGE CHECK:
TO GROUND
27
CONTROL CIRCUIT PRIMARY 127 SECONDARY
A to B 252 B to C 244 A to C 253
A to G 127 B to G 216 A to G 127
AMPERAGE CHECK: #1 36 A 33 B 34 C PHASE
#2 36 A 33 B 34 C PHASE
~3 A B C PHASE
PUMPS SEATED PROPERLY YES OPERATOR HAS RECEIVED INSTRUCTION MANUAL YES
FIELD TEST PERFORMANCE TEST:
~1751 GPM 50 TDH #2. 744 GPM 50 TDH/OTH //GPM
~3 GPM TDH #4 GPM ,/.~_ TD/~O~GPM
I certify this report to be accurate:
Official Start-Up Date: 2/5/01
TDH
TDH
5771 COUNTRY LAKES ORIVE · fORT MYERS. EtORIOA 33905 · 941-693-5228 - tAX 941 693-1485
APOPKA f I MYERS RIVIERA BEACH SAVANNAH
MANUI:AC~URER'$ REPRESENIA~'IVE
WAIER AND WAS'If WAIER TREATMENT EGUIPMENT
JOB NAME
LOCATION OF INSTALLATION Naples, FL
CONTRACTOR Florida S.tate Undergroun~ESIGN CONDITIONS: GPM__
PUMP MODEL Cp3140 H.P. 15 IMPELLER 4'81 VOLTAGE 230 PHASE
SERIAL NUMBER ~1 180-0010031 #2 180-0020047
SERVICE DIVISION START-UP REPORT
ISLAND WALK PH 4 LS #6 OPERATOR Collier County
~3
MANUFACTURER OF CONTROL
OVERLOAD HEATER # B-79
ALTERNATOR TESTED YES
COMMENTS:
TDH
3
fl4
QCI SERIAL fi 03-00-24
L/A CONNECTED YES GROUND CONNECTED
YES
MEGGER CHECK #1 INF RED INF BLACK INF WHITE
#2 INF RED INF BLACK INF WHITE
~3 RED BLACK WHITE
~4 RED BLACK WHITE
VOLTAGE CHECK:
CONTROL CIRCUIT PRIF~RY 125
A to B 243 B to C 249
A to G 125 B to G 209
AMPERAGE CHECK: #1 35 A 33 B 36
#2 34 A 31 B 35
#3 A B
PUMPS SEATED PROPERLY YES
FIELD TEST PERFORMANCE TEST:
TO GROUND
SECONDARY
A to C 250
A to G 125
C PHASE
C PHASE
C PHASE
26
OPERATOR HAS RECEIVED INSTRUCTION MANUAL
fi l 744 GPM 50 TDH fi2 744 .GPM 50 TDH/OTH//////GPM
I certify this report to be .... accurate:
Official Start-Up Date: 2/5/01
YES
TDH
TDH
5771 COUNTRY LAKES DRIVE - fORT MYERS. TLORIDA 33905 · 941.693-5228 - [AX 941.693.1485
APOPK A f T MYERS fllVl[ fl A BEACH SAVANNAH
MANUfACIURER'S REPRESENTATIVE
WATER ANO WASIE WATER IREAIIdENI EQUIPMENT
SERVICE DIVISION START-UP REPORT
JOB NAME ISLAND WALK PH 4 LS #7 OPERATOR Collier County
LOCATION OF INSTALLATION Naples, FL
CONTRACTOR Florida State Undergrou~ESICN CONDITIONS: GPM TDH
PUMP MODEL CP3152 H.P. 23 IMPELLER 454~ VOLTAGE 230 PHASE 3
SERIAL NUMBER #1 180-0020119 ~2 180-0020120
#3
MANUFACTURER OF CONTROL
OVERLOAD HEATER # CC 94.0
ALTERNATOR TESTED YES
COMMENTS:
QCI SERIAL # 2-00-73
L/A CONNECTED YES GROUND CONNECTED
YES
MEGGER CHECK #1 INF RED INF BLACK INF WHITE
#2 INF RED INF BLACK INF WHITE
~3 RED BLACK WHITE
#4 RED BLACK WHITE
VOLTAGE CHECK:
CONTROL CIRCUIT PRIF~RY
A to B 251 B to C
A to G 125 B to G
AMPERAGE CHECK: #1 49 A 54
#2 49 A 54
~3 A
PUMPS SEATED PROPERLY YES
FIELD TEST PERFORMANCE TEST:
#1 877 GPM 60 TDH ~2 869 GPM
~3 GPM TDH #4 GPM
I certify this report to be accurate:
Official Start-Up Date: 2/5/01
TO GROUND
248
219
B
B
B
125 SECONDARY
A to C 251
A to G 125
48 C PHASE
48 C PHASE
C PHASE
26
OPERATOR HAS RECEIVED INSTRUCTION MANUAL
YES
TDH
TDH
5771 COUNTRY LAKES ORIVE · FORT MYERS. t'LORIOA 33905 · 941-693-5228 I'AX 941.693-1485
APOPKA F T MYE R S RIVIERA BEACH SAVANNAH
COLLIER COUNTY UTILITIES
WASTEWATER DEPARTMENT
PROJECT VIDEO REVIEW
9-25-00
DATE OF REVIEW:
PROJECT NAME: Island Walk, Phase 4-B (North)
ENGINEER OF RECORD:
CONSTRUCTION CONTRACTOR:
VIDEO CONTRACTOR: Sewer Viewer
Lines and Services Acceptable
COMMENTS:
RECOMMENDATIONS:
~ ACCEPTABLE:
~ REVIEW NUMBERED COMMENTS IN ONE YEAR:
i t NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE)
~ OTHER RECOMMENDATIONS:
COLLIER COUNTY GOVERNMENT
COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION
ENGINEERING REVIEW SECTION
February 8, 2001
PLANNING SERVICES DEPARTMENT
2800 NORTH HORSESHOE DRIVE
NAPLES, FL 34104
Mr. Scot Morrison
WilsonMiller
3200 Bailey Lane
Naples, FL 34105
941-649-4040
RE: Island Walk Phase 4, Water & Sewer
Dear Mr. Morrison:
A preliminary inspection of the referenced project was conducted by Randy Casey of
the Engineering Review Section of the Planning Services Department on February 8,
2001. Conditions were found to be acceptable, and appear to meet County standards.
If you should have any questions, please do not hesitate to call Randy Casey at (941)
403-2418.
Engineering Inspector
cc:
Lisa Taylor, Engineering Technician, Public Works
Joe Cheatham, Wastewater Director, Utilities
Paul Mattausch, Water Director, Utilities
Diane Deoss, D.O.R. Billing Supervisor
Don Nobles, Engineering Inspections Supervisor
~n_gineering Inspector
· ' ' tion
File
PHONE (941) 403-2400 FAX (941) 643-6968 www. co.collier, fl.us