Loading...
Exhibit EEE 24 Pump Site Plan4116663EXISTING TAMIAMI TRAIL (US-41, SR 45) (PUBLIC - 120' R.O.W.)RACETRAC MARKET5,928 SF RETAILMAX. HEIGHT = 35' (1 STORY)(SEE DETAIL 8, SHEET SD2)DUMPSTER & STORAGE ENCLOSUREEXISTI N G P A L M ST R EET ( P U BLI C - 60' R. O. W.)HANDICAP SPACE (TYP.)(SEE DETAIL 8, SHEET SD2)10'PUMP ISLAND (TYP.)(SEE DETAIL 1, SHEET SD3)S52°01'49"E 496.37'N00°39'49" W 215.21'S89°23'16"W 378.00'N00°39'49" W 135.00'18'40.7'15'67.7'64.8'50'36.3'45'15'30'36'36'50'36.3'45'37.6'37.6'PROPERTY BOUNDARYDETENTION AREA #2S89°23'16"W110.00'6' MASONRY WALLR1-120' UTILIT Y EASE M E NT 18'18'12'10'8'18'10'18'10'ROLLOVER CURB (TYP.)(SEE DETAIL 4, SHEET SD1)6' HIGH VISIBILITYCROSSWALKBIKE RACK10.3'6'9'LIGHT BOLLARD (TYP.)(SEE DETAIL 5, SHEET SD3)E.S.O.S.7.8'6' CONC.SIDEWALK36'10'18'R1-124" WHITESTOP BARR3'R15'R3'R3'R3'R3'R15'R3'R3'R15'R3'R3'R30'R20'R25'R20'R13.5'R18.5'R3'R6'R17'R15'R18'R3'40'104'SEE SHEET SD3 - DETAIL 4 FOR PUMP LAYOUT DETAIL236.2'N00°39'49" W 429.32'PROPERTY BOUNDARYDETENTION AREA #115' C.C.U.E.DETENTIONAREA #3R.O.W.DEDICATION12' R.O.W.DEDICATION135'50'64.6'24" WHITE STOP BAREXISTING FRE D RICK ST REET (PU BLI C - 30' R. O. W.)EXISTING ALLEY (PUBLIC - 20')124.9'EXISTING OFFICELOADING SPACE1' WIDE, NON-VEHICULARACCESS EASEMENTPHASE LINEPHASE 2PHASE 130'BOLLARD (TYP.)(SEE DETAIL 8, SHEET SD2)GROUND SIGN(8' MAX. HEIGHT, 60 S.F. MAX.)AIR/VAC SERVICE STAND(SEE DETAIL 3, SHEET SD2)60'U.E./D.E.WIDTH VARIES3124756811910121513141619171820232122247PLAN REVISIONSDATE DESCRIPTIONTownship:County, State:Part of Section(s):Project Number:Status:Sheet Number:Drawn By:Checked By:Project Manager:FOR PERMITTING PURPOSES ONLY NOT FOR CONSTRUCTIONNOT VALID WITHOUT SEAL, SIGNATURE AND DATE.1605 Hendry StreetFort Myers, FL 33901239-418-0691 239-418-0692 faxFlorida Certificate of Authorization:Engineering LB #: 26978ADFGWSADF2129325 ECOLLIER COUNTY, FLPlanning - Engineering - Project Management11Range:50 SPROJECT:OWNER / DEVELOPER:4/4/2014 1:02 PMK:\21293 - RACETRACE PALM STREET\DO PLANS\PLAN SET\21293-07-SITE-LAYOUT.DWG#PALM STREET(EPN #XXXX)3225 CUMBERLAND BLVD. SUITE 100ATLANTA, GA 30339(770) 431-7600RACETRAC PETROLEUM, INC.NEWS30015 60PROPOSED ASPHALTPAVEMENTPROPOSED CONCRETESIDEWALKPROPOSED LIGHT POLESPROPOSED BOLLARDLEGENDROLLOVER CURBRACETRAC STANDARDPARKING COUNT8LANDSCAPE BUFFER REQUIREMENTSNORTH (TAMIAMI TRL.) 25'EAST (PALM ST.)WEST (FREDRICK ST.)SOUTH (ALLEY)25'25'10'PROPERTY LINEWIDTHPARKING SUMMARYUSERATIOREQUIRED5,928 SF @ 1 SP PER 250 SF24PROVIDED36(2)NOTE: "(#)" REPRESENTS THE NUMBER OF HANDICAP SPACESINCLUDED IN THE TOTAL SPACES.1. ALL SIGNING AND PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE F.D.O.T.STANDARDS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION, THE F.D.O.T.ROADWAY AND TRAFFIC DESIGN STANDARDS, LATEST EDITION, THE MANUAL ONUNIFORM TRAFFIC CONTROL DEVICES AND PUBLISHED STANDARDS.2. PAVEMENT MARKINGS SHALL BE PERMANENT REFLECTIVE TRAFFIC PAINT WITH GLASSBEADS IN ACCORDANCE WITH F.D.O.T. STANDARD SPECIFICATIONS SECTION 710.3. ALL STOP SIGN LOCATIONS SHALL INCLUDE A 24" PAINTED WHITE STOP BAR UNLESSNOTED OTHERWISE.4. ALL SIGNING, PAVEMENT MARKINGS, STREET NAME SIGNS, ETC. ARE TO BE INCLUDEDIN THE LUMP SUM PRICE FOR SIGNING AND MARKING.5. THE CONTRACTOR SHALL COMPLY WITH THE "STATE OF FLORIDA MANUAL OF TRAFFICCONTROL AND SAFE PRACTICES FOR STREET AND HIGHWAY CONSTRUCTION,MAINTENANCE, AND UTILITY OPERATIONS" AND WITH THE MANUAL ON UNIFORMTRAFFIC CONTROL DEVICES".5,928 S.F. OF COMMERCIAL RETAILx5,928 S.F. x 3.12 / 1,000 S.F. = 18.5 C.Y. / MONTH (4.6 C.Y. / WEEK)x1 PICK UP / WEEK = 4.6 C.Y. / PICK UPx4.6 C.Y. / 8 C.Y. PER DUMPSTER = 1 DUMPSTER REQUIREDSIGNING AND MARKING NOTES:SOLID WASTE DISPOSAL REQUIREMENTS:1. ALL CONTRACTORS AND SUB-CONTRACTORS SHALL MAINTAIN THEIR WORK AND THESITE RELATIVE TO THEIR WORK IN ACCORDANCE WITH THE STORMWATER POLLUTIONPREVENTION PLAN AND ALL REQUIREMENTS OF THE PROJECT N.P.D.E.S. PERMIT.2. THE CONTRACTOR SHALL BE RESPONSIBLE TO DEWATER IN COMPLIANCE WITH ALLLOCAL, STATE AND FEDERAL PERMITTING REQUIREMENTS.3. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE COLLIER COUNTY CODE.4. THE CONTRACTOR SHALL RETAIN ON THE WORK SITE AT ALL TIMES COPIES OF ALLPERMITS NECESSARY FOR ANY CONSTRUCTION.5. THE CONTRACTOR SHALL NOTIFY THE OWNER AND CONTACT ALL UTILITY COMPANIESFOR LOCATIONS OF EXISTING UTILITIES IN THE AREA 72 HOURS (MINIMUM) PRIOR TOCOMMENCING CONSTRUCTION.6. THE LOCATION OF EXISTING UTILITIES, SIDEWALKS, PAVEMENT, VEGETATION ANDMISCELLANEOUS IMPROVEMENTS ARE APPROXIMATE. THE EXACT FIELD LOCATIONSSHALL BE VERIFIED BY THE CONTRACTOR IN THE FIELD PRIOR TO COMMENCING ANYCONSTRUCTION.7. THE NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988 IS THE BENCHMARK DATUMFOR THIS PROJECT.8. ANY PUBLIC LAND CORNER WITHIN LIMITS OF CONSTRUCTION IS TO BE PROTECTED.ANY LAND CORNER MONUMENT IN DANGER OF BEING DESTROYED MUST BE PROPERLYREFERENCED BY THE CONTRACTOR.9. EXISTING IMPROVEMENTS SHALL BE RESTORED TO A CONDITION EQUIVALENT TO THATWHICH EXISTED PRIOR TO COMMENCING CONSTRUCTION, AT NO ADDITIONAL COST TOTHE OWNER.10. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ELEVATIONS PRIOR TOCOMMENCEMENT OF CONSTRUCTION. ANY DEVIATION IN PLAN INFORMATION SHALL BEREPORTED TO THE ENGINEER AND OWNER'S REPRESENTATIVE IMMEDIATELY.11. CONTRACTOR IS REQUIRED TO OBTAIN FROM THE ENGINEER WRITTEN APPROVAL FORANY DEVIATIONS FROM THE PLANS AND/OR SPECIFICATIONS.12. UNDERGROUND CONTRACTOR SHALL MINIMIZE THE WORK AREA AND WIDTH OF ALLTRENCHES TO AVOID DISTURBANCES OF NATURAL VEGETATION. SPOIL FROMTRENCHES SHALL BE PLACED ONLY ON PREVIOUSLY CLEARED AREAS OR AS DIRECTEDBY THE OWNER. CONTRACTOR SHALL NO REMOVE OR DISTURB ANY TREES AND/ORSHRUBS WITHOUT PRIOR APPROVAL OF THE OWNER.13. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING TRAFFIC AND USAGE OF THEEXISTING STREETS ADJACENT TO THE PROJECT. ALL TRAFFIC MAINTENANCE CONTROLSHALL BE IN ACCORDANCE WITH FLORIDA MANUAL OF TRAFFIC CONTROL AND SAFEPRACTICES FOR STREET CONSTRUCTION, MAINTENANCE, AND UTILITY OPERATIONS.TRAFFIC CONTROL OPERATION PROCEDURES SHALL BE SUBMITTED TO THE OWNERFOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUCTION.14. EASEMENTS DEPICTED ON PLANS ARE PROPOSED UNLESS OTHERWISE NOTED.15. THE APPROVAL OF THESE CONSTRUCTION PLANS DOES NOT AUTHORIZECONSTRUCTION OF REQUIRED IMPROVEMENTS WHICH ARE INCONSISTANT WITHEASEMENTS OF RECORD.GENERAL DEVELOPMENT NOTES: BUILDINGSITE LAYOUT, SIGNING,MARKING AND ZONINGDATA PLANLAND USE SUMMARYCATEGORYAREABUILDING / ROOFSIDEWALK / PARKINGPERCENTAGE7.3%62.0%0.31 AC.2.63 AC.CURRENT PHASEOPEN SPACE 17.7%0.75 AC.DRY DETENTION TOP 13.0%0.55 AC.TOTAL 4.24 AC.SITE DEVELOPMENT REGULATIONS (LDC 5.05.05MINIMUM LOT AREA (SQ. FT.) 30,000MINIMUM LOT WIDTH (FT.)MINIMUM LOT DEPTH (FT.)SEPARATION FROM ADJACENT AUTOMOBILE SERVICE STATIONS (FT.) 150180500DEVELOPMENT STANDARDSREQUIREDPROVIDED(BASED ON ON DISTANCE BETWEEN NEAREST POINTS)MINIMUM SETBACKS, ALL STRUCTURES:FRONT YARD (TAMIAMI TRAIL EAST) (FT.)SIDE YARD (FT.)REAR YARD (FT.)504040184,804378.0215.2143.764.864.667.7NOTES:1. GAS STATION WAIVER IS BEING APPLIED FOR CONCURRENT WITH THIS APPLICATION.1 SPACE FOR 5,000-10,000 SF 1 1LOADING SPACE5% OF REQUIRED SPACES22BICYCLE PARKING(2 SPACE MIN.)COMMERCIAL BUILDING PARAMETERSUNITS PER BUILDING 1TOTAL UNITSSITE ACREAGENUMBER OF STORIES14.24 AC.1 (27 FEET)BUILDINGS 1GROSS FLOOR AREATYPE OF CONSTRUCTIONOCCUPANCY USE5,928 SFV-BMERCHANTILE (M)FIRE SPRINKLERS YESWEST (EX. OFFICE)SOUTH (EX. OFFICE)5'5'NOTES:1. PER LDC SECTION 5.05.05.D.12. PER LDC SECTION 4.02.16.E.2.9REQUIRED FIRE FLOW 2,000 GPMAVAILABLE FIRE FLOW 2,962 GPMNOTES:1. CONSTRUCTION TYPE PROVIDED BY ARCHITECT.2. REQUIRED FIRE FLOW DETERMINED FROM 2010 NFPA 1, TABLE 18.4.5.1.23. AVAILABLE FIRE FLOW FROM FIRE FLOW TEST DATED 3/14/2014.PHASE LINE123FOR AUTOMOBILESERVICE STATION111222100.0%1