Loading...
Agenda 01/26/2016 Item #16E 2 1/26/2016 16.E.2. EXEC('TINE St NIMARV Recommendation to waive competition for a sole source vendor and approve the continued amendment of the [.rase Agreement for a Confined Space Gas Monitoring System with Industrial Scientific. OBJECTIVE; To protect employees who must work within confined spaces from illness, injury or death through the approval of a lease agreement with Industrial Scientific for a Confined Space Gas Monitoring System. CONSIDERATIONS:, The Board entered into a lease agreement with Industrial Scientific fix Confined Space Gas Monitoring and 'Testing Equipment on 9/27/2011 under Agenda Item 16E1. At that time, the Board declared Industrial Scientific a sole source provider for the type of system needed by the County. The Board entered into an agreement upon which the term was to expire on December 31, 2015, unless the extension option was exercised. Staff exercised a one (I ) month extension(until January 31, 2016) so as to complete final negotiations and review by the vendor and staff. The purpose of the system is to allow field employees to detect hazardous atmospheres such as low oxygen, flammable gases and/or combustible gases before conducting work within tanks, lift stations, storm sewers and similar confined spaces. Detection is accomplished through the use of portable monitoring units. The Industrial Scientific system provides redundancy through a centralized monitoring system that constantly monitors the units and warns the appropriate safety and management staff when a unit has not been properly maintained and/or calibrated. These units and the accompanying monitoring system are an invaluable life safety tool for those employees echo must work in confined spaces. Staff believes that Industrial Scientific is a sole source vendor for this type of system due to its monitoring redundancy feature. Therefore, the Risk Management staff, with affirmation from the user Divisions recommends the continued lease of the Industrial Scientific System far the following reasons: I► Industrial Scientific is the only system that offers redundant monitoring capability. Staff is notified by email within 1 minute of any readings outside the Permissible Exposure Limit. The monitoring service also detects calibration and maintenance defects instantly without being dependent upon a program manager who may be checking the system 1-2 times per day. 2) The monitoring service triggers the shipment of new units automatically within 24 hours of a detected defect. 3) The lease program allows the County. to upgrade to new, state of the art product models when they are introduced, w ithout additional financial impact to the County during the contract life. 4) The lease program largely eliminates the need tar departments to order, Install and maintain new parts. This greatly increases efficiency and reduces the amount of time each program manager spends maintaining their gas monitors. 5) The recommended leasing program will result in a S10?39.36 cost savings over the contract life when compared to our current lease. Pursuant to Section 9 of the Board's Procurement Ordinance,the Procurement Services Director believes it is in the best interest of the County to\Salve competition as a sole source vendor due to the safety and redundant features that only this vendor is able to pros ide. FISCAL IMPACT: The total cost of the lease over the 4 year leasing period is $1 17,754.56. The new lease offers a cost sayings of $10,239.36 over the contract life when compared to the expiring lease. Funds are budgeted within the operating budgets of each affected department for this lease. Packet Page - 895 1/26/2016 16.E.2. GROWTH SLL\AGE\IE\T IMPACT:, There is no eroyyth management impact associated with this Executive Summary. I EG_1L CO\SIDERITIONS, This item has been approved as to form and legality' and requires majority rote for approval, —CMG RECOMMENDATION., That the Board of County Commissioners naives formal competition for a sole source vendor and approves the continuation of a lease Agreement for Confined Space Gas Monitor System yvith Industrial Scientific as outlined herein and authorizes the Chair to sign the County Attorney approved agreement. J R PARED BY: Ron Miller. Inv ironmental. l Iealth& Safety Manager, Risk Management Division Attachments: I) Sole Source Letter 2) Agreement- industrial Scientific Packet Page - 896 1/26/2016 16.E.2. COLLIER C'O :_. TTY 4za2rc unr', item Number: 16.16.E.16.E.2. Item Summary: Recommendation to waive competition for a sole source vendor and approve the continued amendment of the Lease Agreement for a Confined Space Gas Monitoring System with Industrial Scientific. Meeting Date: 1/26/2016 Prepared By Name: WalkerJeff Title: Division Director-Risk Management,Risk Management 12/22/2015 10:24:07 AM Submitted by Title:Manager-Environmental Health &Safety, Risk Management Name: MillerRon 12/22/2015 10:24:09 AM Approved By Name: pochopinpat Title: Operations Coordinator, Administrative Services Department Date: 1/6/2016 4:34:33 PM Name: JohnsonScott Title: Manager-Procurement, Procurement Services Date: 1/7/2016 12:40:44 PM Name: MarkiewiczJoanne Title: Division Director-Procurement Services,Procurement Services Date: 1/8/2016 6:43:56 AM Name: PriceLen Title: Department Head-Administrative Svc, Administrative Services Department Date: 1/8/2016 1:15:36 PM Packet Page -897- 1/26/2016 16.E.2. Name: WellsLaura Title: ManagementBudget Analyst, Senior. Office of Management& Budget Date: 1/13/2016 3:32:37 PM Name: KlatzkowJeff Title: County Attorney, Date: 1/15/2016 10:51:42 AM Name: CasalanguidaNick Title: Deputy County Manager, County Managers Office Date: 1/15/2016 12:31:27 PM Packet Page-898- '726/2016 16.7-.7. ! BSc r T r-r P t.sb Ir 205 ?none 41L-785-435: 1-805-DETECTS (335-3257) Fax: 412-788-8353 www.indsci.corn December 11, 2015 Collier County Mr. Ron Miller, Jr. 3311 Tamiami Trail E. Naples, FL 34112 Dear Mr. Miller: RE: iNet Instrument NetworkTM This letter serves to confirm that Industrial Scientific Corporation is the sole source provider of the patented iNet Instrument NetworkTA" (US Patent 6,442,639). Industrial Scientific remotely monitors the condition of your Industrial Scientific instrument fleet and automatically handles any necessary service requirements based on the Exchange Plan that you have selected. In addition, the program also includes iNetTM Control which provides visibility into your gas detection program via the Web. By logging onto a secure website you can review equipment usage, maintenance and alarm events. iNetTM Control tells you when your gas detectors were last calibrated, whether a sensor is about to fail, and which gas detectors went into alarm that day. You can use detailed views to identify the source of potential problems, take action, and save lives. There is no other comparable all-inclusive gas detection program like iNetTM in existence today. Please contact us if we can be of further assistance. Sincerely yours, -tt tl I Garth F. Miller Vice President, Customer Operations OUR MISSION Preserving human life on,above and below the earth Delivering highest quality.best customer service... OHSAS 18081 ISO 9001 ISO 14001 ` Certified Certified Certified Packet Page -899- 1/26/2016 16.E.2, Agent of Amendment Renewat'Equipment Change Collier County 51031 Case Number:20151223-4365r Agreement of Amendment ?tr i,.meriemen. i:., mad: F—,tu.sar, 2C:c]. by anc Detw _, i D _iy OR_PORATION, terms}lvani. corporatio:. '"(7..arnpanT. ami COLLIER CO-T.,7-`'. 1-ioridL County Ciovernmeni ('Customer"). Company and Customer entered into an iNet Usage Agreement dated July 12,2011 (the"Agreement"),under which Company agreed to provide its iNet gas detection services to Customer for an Initial Term that commenced January 1, 2012 through December 31,2015, with automatic month-to-month basis renewals and; Company and Customer desire to extend the Initial Term of the Agreement and to revise the Subscription Fees and the Equipment covered by the Agreement as detailed below. Company and Customer hereby agree to amend the Agreement as follows: I. Except where the context otherwise requires, words and expressions defined in the Agreement shall have the same meanings when used herein;references to sections are to sections of the Agreement. 2. Section 1,"Subscription," is amended to provide that the Term of the Agreement will be renewed"Renewal Term"for one month under the Initial Term and then extend for a period of forty-eight(48)months, such that the Term shall commence February 1, 2016 and expire on January 31, 2020 (the"Amended Term"). The definition of the word"Term" as defined in Section 1 of the Agreement is also amended to include the Amended Term and Renewal Term, 3. Section 2,"Subscription Fee and Costs," is amended to provide that the one additional month under the existing Term will be billed at $2,453.22 and the total cost of the Subscription for the additional forty-eight (48)-month Amended Term is $117,754.56, billed to Customer as follows: forty-eight(48)invoices for monthly installment payments of$2,453.22. 4. As Customer desires to change the Equipment provided by Company during the Initial Term, Schedule B will be replaced by the attached Schedule B. During the Amended Term, Company will provide to Customer the Equipment identified on the attached amended Schedule B. 5. All other terms and conditions of the Agreement shall remain unchanged and in full force and effect except where modified by this Agreement of Amendment. The parties hereto have executed this Agreement of Amendment effective as of the date and year first above written. INDUSTRIAL SCIENTIFIC CORPORATION COLLIER COUNTY By: By: Name: Name: Title: Title: DWIGHT E.BROCK,CLERK OF COURT Approved as t fo if e!. ' i1 By: By Ihiai! A Deputy Cletk Jeffrey A.7 at .. aunty Attorney 1 Packet Page -900- r oilier Coup;:, 5103: ase Number.2(C. 1 2123 3e511 1 121.,11-1_ T l- ompany will ship the following equipment: Qty Part Number IDescription 13 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4, 3 inlet ports,2 iGas readers, North America power cord 3 18109331-131 DSXi Cloud-Connected Docking Station for GasBadge Pro,3 inlet ports,2 iGas readers,North America power cord The following Equipment is onsite and will remain onsite: Qty Part Number Description 13 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor, LEL(Pentane), CO, H2S, 02, Lithium-ion Extended Range Battery, Desktop Charger,Pump, High-Visibility Orange,UL/CSA, Soft Case,English 1 18100060-6 11GasBadge Pro-Ammonia(NH3) 2 18100060-7 GasBadge Pro-Chlorine(Cl2) 10 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 1 18105858 iGas Regulator w/Pressure Switch for 650L Cylinders 10 17124348 Wall Mounted Gas Cylinder Holder 3 18105924 5-Port Gas Regulator Manifold 13 18101386 Stainless Steel Probe(6 ft Extendable) Customer will return the following Equipment: Qty Part Number 11 Description -13 18108918 iNet DS Docking Station for Ventis MX4 -3 18108915 iNet DS Docking Station for GasBadge Pro Monthly Fee Breakdown Amount Wastewater Collections 8579.52 Risk Management $304.80 South Rater $394.82 North\N'ater $304.80 \Water Distribution 8144.88 Well fields $144.88 South\wasterwater 8289.76 North Wastewater $289.76 $2,453.22 7 Packet Page -901- 1/26/2016 16.E.2. Agmt of Amendment Renewal Equipment Change Collier County 51031 Case Number:20151223-436587 .a t. caiick;: Location#1 —Wastewater Collections 3027 Shirley St Naples.FL 34100 ,Qty Part Number Description 4 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor, LEL(Pentane), CO, H2S, 02, Lithium-ion Extended Range Battery, Desktop Charger, Pump, High-Visibility Orange, UL/CSA, Soft Case, English 4 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports, 2 iGas readers, North America power cord 1 18105858 iGas Regulator w/Pressure Switch for 650L Cylinders 1 18105924 5-Port Gas Regulator Manifold 4 18101386 Stainless Steel Probe(6 ft Extendable) Location#2—Risk Management 3311 East Tamiami Trail Naples,FL 34112 Qty Part Number Description 1 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor, LEL(Pentane),CO, H2S,02, Lithium-ion Extended Range Battery, Desktop Charger, Pump, High-Visibility Orange, UL/CSA, Soft Case, English 1 18100060-6 GasBadge Pro-Ammonia(NH3) 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports,2 iGas readers, North America power cord 1 18109331-131 DSXi Cloud-Connected Docking Station for GasBadge Pro, 3 inlet ports,2 iGas readers, North America power cord 2 18105841 iGas Regulator w/Pressure Switch for 581103L Cylinders 1 17124348 Wall Mounted Gas Cylinder Holder 1 18101386 Stainless Steel Probe(6 ft Extendable) Location#3—South Water 3851 Utility Dr Naples,FL 34117 Qty Part Number Description 1 VTS-K1232111111 Ventis MX4 Multi-Gas Monitor, LEL(Pentane), CO, H2S, 02, Lithium-ion Extended Range Battery, Desktop Charger, Pump, High-Visibility Orange, ULICSA, Soft Case, English 1 18100060-7 GasBadge Pro Single-Gas Monitor-Chlorine(Cl2)—Initial Supply of Battery Only. Replacement batteries must be purchased by customer 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports, 2 iGas readers, North America power cord 1 18109331-131 DSXi Cloud-Connected Docking Station for GasBadge Pro, 3 inlet ports,2 iGas readers, North America power cord 2 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 2 17124348 Wall Mounted Gas Cylinder Holder 1 18101386 Stainless Steel Probe(6 ft Extendable) 3 Packet Page -902- R r- rt `/26/201 1 6.`.%. CoiiierCount 5103t a ;e Numnc, 5ril';1?2=-`3r= 'r{7 R ,t9C2L 7r r- tdF °T.C761- t ` __..--- Ci iE Ea a 1C' „3.,� .. elTI u.. _- — 1lBatter ✓esiio, Cnarge r 1pn-visioili Orange. Sot. Case, EngiiSr, 1[18 100u5 . lloasBadg e Pro-Chlorine (CL 2) li 1 ( 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports. 2 iGas readers North America power cord 1 18109331-131 DSXi Cloud-Connected Docking Station for GasBadge Pro, 3 inlet ports,2 iGas readers, North America power cord 2 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 2 17124348 Wall Mounted Gas Cylinder Holder 1 18101386 Stainless Steel Probe(6 ft Extendable) Location#5—Water Distribution 4370 Mercantile Ave Naples,FL 34104 Qty Part Number Description 1 VTS-K1232111111 I Ventis MX4 Multi-Gas Monitor,LEL(Pentane),CO, H2S,02, Lithium-ion Extended Range I I I Battery, Desktop Charger, Pump, High-Visibility Orange, UL/CSA, Soft Case, English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports,2 iGas readers, North America power cord 1 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 1 17124348 Wall Mounted Gas Cylinder Holder 1 18101386 Stainless Steel Probe(6 ft Extendable) Location#6—Wellfields 4370 Mercantile Ave Naples,FL 34104 Qty Part Number Description 1 I VTS-K1232111111 Ventis MX4 Multi-Gas Monitor, LEL(Pentane), CO, H2S, 02, Lithium-ion Extended Range I II Battery,Desktop Charger, Pump, High-Visibility Orange, UL/CSA,Soft Case, English 1 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports,2 iGas readers, North America power cord 1 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 1 17124348 Wall Mounted Gas Cylinder Holder 1 _118101386 Stainless Steel Probe(6 ft Extendable) Location#7—South Wastewater 5600 Warren St Naples,FL 34113 ,Qty Part Number Description 2 IVTS-K1232111111 Ventis MX4 Multi-Gas Monitor,LEL(Pentane), CO, H2S, 02, Lithium-ion Extended Range Battery, Desktop Charger, Pump, High-Visibility Orange, UL/CSA, Soft Case, English 2 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4,3 inlet ports, 2 iGas readers, North America power cord 1 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 1 17124348 Wall Mounted Gas Cylinder Holder 1 18105924 5-Port Gas Regulator Manifold 2 18101386 Stainless Steel Probe(6 ft Extendable) 4 Packet Page -903- /20 E6 1'i.E 2, aui.o_Amendment Aenewal Ecru/mu-nr C11(1171!: Coiner Count 510_i _' !_c�. � Lam.._._ fr �. L..� r�.. • ..� .c � - �t., i Numbe. ilDescrimior, VTS 3 i �V'entls M X4 kilulli vas Moons: (Pentane,. fniu :ori E i u;Ci �c Bate IDesl:top Charger. Pump High-Visibility Orange. U_/CS4,. Soft Case English �I 2 ' 18109327-131 DSXi Cloud-Connected Docking Station for Ventis MX4. 3 inlet ports, 2 iGas readers, North America power cord 1 18105841 iGas Regulator w/Pressure Switch for 58/103L Cylinders 1 17124348 Wall Mounted Gas Cylinder Holder 1 18105924 5-Port Gas Regulator Manifold 2 18101386 Stainless Steel Probe(6 ft Extendable) 5 Packet Page-904-