Shores @ Berkshire Lakes Ph 2-AMEMORANDUM DATE: February 26, 2000 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II~/ Project Plan Review RE: Shores @ Berkshire Lakes, Phase 2-A Water and/or Sewer Facilities Acceptance Recording Fee Number 113-138312-649030 On ~/~//. ~ , ~ The Board of County Commissioners granted final acceptance of the water and/or sewer facilities within the above-referenced project· Attached, please find the following recorded, in order: 1. Utilities Facilities Subordination, Consent and Joinder 2. (2) UCC-3's 3. Bill of Sale 4. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. 10. 11. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Certification of pressure testing of sewer lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities Memorandum to Maureen Kenyon, Supervisor, Clerk to Board February 26, 2000 Page Two 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. DER Placement-in-Service letter for sewer facilities Contractor's Final Release of Lien Lab results on bacteriological test for water lines Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division Letter from fire district regarding certification of field fire flow capacity testing Certification of the inflow/infiltration test for the sewer lines by Engineer of Record Coating certification of man holes, wet wells and dry well from manufacturer Electrical Contractor's certification on Pump Station electric service wire sizing and voltage drop, pursuant to National Electrical Code specification Copy of pump station start-up report Copy of video tape test report Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations Memorandum to Maureen Kenyon, Supervisor, Clerk to Board February 26, 2000 Page Three If you have any questions, please call and advise accordingly. attachments doc:2094-2 Dwight E. Brock Clerk County of Collier CLERK OF THE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301 TAMIAMI TRAIL EAST P.O. BOX 413044 NAPLES, FLORIDA 34101-3044 OFFICIAL RECEIPT When Validated BRANCH OFFICES: GOLDEN GATE 4839 GOLDEN GATE PARKWAY GREENTREE SHOPPING CENTER 2386 IMMOKALEE ROAD IMMOKALEE 101 $. FIRST STREET MARCO ISLAND 1040 WINTERBERRY DRIVE EVERGLADES CITY 207 BIROADWAY AVENUE ~ECEIPT: 3166-773 'AYOR: BCC 113 1383i2 649030 !EF: ENGINEERING REVIEW,." S DC: 5 [O~UMENT~ NIX DESCRIPTION AMOUNT DUE RECORDING OF LEGAL INSTRUMEN 57.0C) P.R.M.T.F. RECORDING FEE 9.00 DOCUMENTARY STANPS - 70 .70 iOC TYP FILE ID BOOK PAGE UBORD 2613250 2657 03~,_,' UCC 261~· ~ =~ . iUCC 2613~._~' "S" =6._,~ ==, 033n. : SALE 26t3~._,W ~._, 0332 EED 2613254 ~ ~- ~6._r 0335 ~. 221J29~ OJ/JO/2OOD "BILLED: "70 MW ANT -,,n, EPT: RECORDING TOTAL DUE: ~6.70 2613250 OR: 2657 PG: 0325 BICOI~ID in O]~;IClAL liCOILDS o[ CQLLIBR CQrI~T, FL o~/2o/2ooo ,t o?:5~ ~,~ 1, BM, IIC FII 15.00 SHIILI! Exhibit A - Description of Real Property UTILITY FACILITIES SUBOP~)IN3%TION, CONSENT AND JOINDER THI~q SUBORDINATION, CONSENT AND JOINDER given this /~day of ~t[ ~ D , 1999, by AMSOUTH BANK, formerly known as AMSOUTH BAi~K OF FLORIDA, (hereinafter referred to as "Mortgagee"), in favor of the BOARD OF COUNTY COMMISSIONERS OF COLLIER COU~NTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "County"). Mortgagee is used as singular or plural, as the context requires. W I TNE S SETH : WHEREAS, Mortgagee is the owner and holder of that certain Mortgage, Security Agreement and Assignment of Rents recorded in Official Records Book 2004, pages 1602 through 1622, as modified by Loan Modification Agreement and Notice of Future Advance Receipt recorded in Official Records Book 2345, pages 1087 through 1099, and Second Loan Modification Agreement And Notice Of Future Advance Receipt recorded in Official Records Book 2507, pages 274 through 279, all Public Records of Collier County, Florida (hereinafter referred to as "Mortgage"), encumbering the premises legally described therein, (hereinafter referred to as the "Encumbered Property"), and WHEREAS, Mortgagee is the owner and holder of that certain Assignment of Rents, Leases, Profits and Contracts recorded in Official Records Book 2004, pages 1623 through 1638, Public Records of Collier County, Florida (hereinafter referred to as "Assignment of Rents," and WHEREAS, Mortgagee is the owner and holder of that certain UCC Financing Statement recorded at OR Book 2004, pages 1639 through 1648, Public Records of Collier County, Florida, and that certain UCC Financing Statement filed with the Florida Secretary of State at File No. 94 0000246592 (hereinafter referred to as UCC Statements), which statements encumber non-real estate interests located within the "encumbered property," and WHEREAS, County has received from the fee simple owner of the Encumbered Property non-exclusive easements for the installation and maintenance of utility facilities over and across a portion of the encumbered premises legally described in Exhibit "A" attached hereto and incorporated herein by virtue of this reference, which premises are hereinafter referred to as the "Easement Property," and -1- OR: 2657 PG: 0326 WHEREAS, County has requested that Mortgagee consent to, join in and subordinate its Mortgage, Assignment of Rents, and UCC Statements to The interest that County has in the Easement Property and in the utility facilities located within the Easement Property to which request Mortgagee has agreed. NOW, THEREFORE, in consideration of TEN DOLLARS ($10.00) and other good and valuable consideration, the receipt of which is hereby acknowledged, the Mortgagee does hereby consent to, join in and subordinate the lien of its Mortgage, Assignment of Rents, and UCC Statements (as those liens are identified heretofore in this instrument), to the grant of easement described herein and any interest of the County in any utility facilities located therein or affixed thereto. Except as subordinated to the easement described herein over, under, and across the Easement Property or any utility facilities located therein or affixed thereto, said Mortgage shall remain otherwise in full force and effect. IN WITNESS WHEREOF, the Mortgagee has caused these premises to be executed the date and year first above written. Witnesses: ~RB/~4 B£NNET~ Prin~ Name of Witness Print Name of Witness AMSOUTH B;hNK, F/K/A AMSOUTH BANK OF FLORIDA BY: PrintIts N~/.m~ o f . Officer STATE OF FLORIDA CO~TY OF COLLIER The foregoing instrument was acknowledged before me on the / day of Q-~ , 1999, by ~~ ~ ~'~/ as ~--~.m~ off. SOUTH B~K, F/K/A ~SOUTH BANK OF FLORIDA, on behalf of the Bank. He is ~ personally kno~ to me, or __ has produced as identification. Notary Public Print Name of Notary Public My Co~ission Expires: PREParED BY: Thomas E. Maloney, Esquire Quarles & Brady 4501 Tamiami Trail North, Suite 300 Naples, Florida 34103 .,.~ Bathurst Bennett -2- *** OR: 2657 PG: 0327 *** EXHIBIT A Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book ~, pages /t 0 through O / , Public Records of Collier County, Florida. NOTE: T~is ~s a two-part term. Send both paris to the Department el State for filing. It S copy of this form is needed prior to tiling, make photocopies for your records. · ~_ :', ~ '~ ,'-':~ IMPORTANT' Read instructions on back before filling out form. Scminol~ Form UCC-3 STATE OF FLORIDA UNIFORM COMMERCIAL CODE STATEMENT OF CHANGE FORM UCC-3 (REV. 1993) This Statemenl el Change is presenled to a tiling officer pursuant to the Uniform Comm0rcial Code: 1. Debtor (Last Name First if an Individual) ~ la. Data of Birth or FEI# Coast Communities Corporation 'b'~"~r~port Road South 2. Addi~-k~-~l-b~o{o~; 6~' Trade Name'(i-cat Name First If an Individual) ! 2a. Date of Birth or FEI# Higgs, William T., as Trustee and Individually I 2~. Milling Address 2666 Airport Road South i Naples, FL i 34112 ~s~ured Party (Las{ Neme Fi~t' if an individual) AmSouth Bank of Florida 3~-Maillrt~ -A(id~s' i . ...... 4~51 Tam~-amz Trail North I N;~les, FL ~ 34103 4. Additional ,Secured Party (Last Name First If an Individual) ..................... 4b:~it~: Stal~ ................. 4c:Zlp'C0~ This StatemLmt refers to original Financing St~temenl bearing file number: 940000246592 flied on__.~. 2 / 8 / 94 . 7. De~ of cellini ra~s~,d or aealgned, Assignee ~me and ~dress, or a~nd~nt. Use additional shset(s) If n~es~. ~ll ~ater an~ se~e~ £ac~l~ties locate~ ~[th±~ the property deacr~be~ in Exhibit A. RICO .................................. o3t3 AmSouth f/k/~ )uth BY: C~, State. Z'e . Bank of Flor~da~]] IX? 4 Additional S~ ~esent~ 1. P. elum Copy to: N~ Thomas E. Maloney, Esq. I Quarles & Brady LLP [ ~ 4501 Tamiami Trail N., Suite 300 Naples, FL. 34103 This space for use of Filing Officer 1613251 OR: 2657 PG: 0328 i/ZOO0 at 07:58J~ OIl~? !. BROC[, C~IR[ I~C ~g! [0.50 A~roved by Sec, celery of Stale, Stata et Florida FILING OFFICER COPY STANDARD FORM - FORM UCC-3 *** OR: 2657 PG: 0329 *** Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book .~, pages [t (J through O [ , Public Recor~'s of Collier CounW, Florida. NOTE: This is a two-part form. Send both parts to the Department of State lot filing. If a copy of this torm is needed pdor to filing, make photocopies lot your re~ords 0 ~ :2 ~ 7 IMPORTANT: Read instructions on back before filling out form. Seminole Form UCC-3 STATE OF FLORIDA UNIFORM COMMERCIAL CODE STATEMENT OF CHANGE FORM UCC-3 (REV. 1993) This Stalement ol Change is presented to a filing officer ff. Jmuan! Io the Uniform Commercial CoDe: 1. D~31:or (Last Name First i! an Individual) lb. Mailing Address i 1~. ci~:s{a~e ' ' ; ld Z P Code 2666 Airport Road South l Naples, F:L i 34112 ~.--~iil0nal}{iggs ,D~t0~' Wi .]..]_ i ara°r Trade Name?.(Last, asHame TrusteeFIrst ii' an Individual) 2a. Date 0i Birth or FEM ~-~-. M~ I~ I~-A~cl ~'~s~ .......... ~ 2~.. Ci{'y;-~ ......... ' 2d. Zip Code 2666 Airport Road South [ Naples, FL i 34112 3. Secured Party (Last Name First if an Individual) AmSouth Bank of Florida ...........................3a. 14i~ltng Address 3b. CltYl State- ~(:. Zip ~, FL 34103 t Naples, 4851 Tamiami Trail North , [ ..... ),~-Xc~ilt'l~i Se~red'p,i~ (Last Name FI}st ii'~n IndiVidual) Mailing Address ~ ......................................... ~K ~, S~i~ .............. 14c~ zip c~e / 6. A. E~ Continuation- S.:~ Release - C. ~ FulI Assignment- D. [~ Partial Assignment - E. ~1 Amendment- F. [~ Termlnatlo~- This Statement refers to original Financing Statement bearing file number: filed of c~Mteml r~ased or assigned, A~nee na~ and address, or amerKtme~t UM Kk:llUonal sheet(s) If neces~. ~1~ ~atec and se~ec ~ac~l~b~es Zocabe~ v~bh[n Lhe pcope~y described ~n ~xh~b$~ ~. This space for ,JSe Of Filing Officer of Debtor(s): (only If amendmen¥- see Instructions} !613252 OR: 2657 PG: 0330 in OHICIU, [llCO~.~ of C0LLIll C01~111, IL 0/2000 at 07:58~ D~IG~ l, Bl0CI, CLIE[ BC FII 10.50 AmSouth Ba~,//_k/a ........... /~--:_ ?--/ .... ~ -- : p/ 10. Nombe~ Of Addlflona[ Sheets Presented Bank of Florida III 11. Return Copy to: t,~,ne Thomas E Maloney, Esq. . Quarles ~ Brady LLP 'Add,~ 4501 Tamiami Trail North Ad~ Suite 300 Naples, FL. 34103 C~,~me,~ *** OR: 2657 PG: 0331 *** Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to thc. plat thereof recorded in Plat Book ~/~, pages &.0 through ¢] , Public Records of Collier County, Florida. BIL50~ ~A~ THIS BILL OF SALZ evidencing the sale, and conveyan.ce_~f the water ut_llitV, facilities described herein _s made this ~_~ day of . -] ~..~..'P--- ., ig ._9_~_, by CO~-~T COl--!TIES CORPORATrON, A B-LORIDA CORPORATION, (hereinafter referred to as "Seller"], and the BOA/ED OF COI/NTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE .: GOV~R_N!NG BODY OF COLLIER COTJRTY AND ;kS EX-OFFICIO THE GOVER_~ING" BOJ~J~D OF TE]~ COLLIER COtINTY WATER-ST.W~R DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). WI TNt S S£ TH : That said Seller, for and in consideration of the sum of Ten Dolizrs ($10.C0) and oZher good and valuable ¢onslderaticn to said Seller in hand paid by the smid Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant bargain, sell, transfer, set over and deliver unto :he Buyer, and :he Buyer's heirs, successors and sssigr, s forever, all those certain water and sewer ut£lity facili:ies lying wi:hin the following described land, to~ether with ~ppurtgnant easement righ:s for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wi%: (See Exhibit "A" attac~ed hereto and incorporated by reference herean.) The Seller, for itself and its successors, hereby covenan=s ~o and with the Buyer and it~ successors and assigns that it is the lawful o~T. er of the said goods and chattels herein referred to as u~ility facilities; :hat said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that l~ will warrant ~nd defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context req&lres. 2613253 OR: 2657 PG: 0332 llCOIDID in OFFICIAL RICO~S of COLLIBi COmfY, FL 02/30/2000 at 0?:58AN DNIG~Y I. BLOCK, CLBll [lC l~l 15,00 Beth: BNOIIIIIIN$ IIYIl¥ SIIVICI! ~IRLIY NIZ TOTAL PAOE.86 *~ OR: 2657 PG: 0333 IN WITNESS WHEREOF, SELLER has caused these presents to be executed the date and year first above written. Witnesses: Print Name of W~tness GAROL ANN~ANTFELD Print Name of Witness COAST COMMUNITIES CORPORATION A FLORIDA CORPORATION Wiil~na~. Higgs, ~5~sident: STATE OF FLORIDA COUNTY OF COLLIER behalf of the Corporation. or has produced identification. The foregoing instrument was acknowledged before me on the / day of .~~z__ , 1999, by WILLIAM T. HIGGS, PRESIDENT, COAS~CO~'14UNITIES CORPORATION, A FLORIDA CORPORATION, on He is ~ personally known to me, as NOTARY PUBLIC CAROLANI~NTFELD Print Name of Notary Public MY COMMISSION EXPIRES: Prepared by: Thomas E. Maloney, Esquire QUARLES & BRADY 4501 North Tamiami Trail Suite 300 Naples, Florida 34103 OEP\ 183557, -2- *** OR: 2657 PG: 0334 Tract R, Thc Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book fl,?'._, pages G~/9 through ~ / , Public Records of Collier County, Florida. ~ate of FLORIDA C,o~mty of COLLIER., I ~RI~BY CERTIFY .MT corr~t cOpS of:.i ~c~nt rec~d in WIT~SS ~.~ ba~d~ ~efftcial: ~l this ~cpe~F rD No. --~ UTILITY FACILITIES W~-~NTY DEED between CO~T ~O~igJNITIES ~oR-~OP~".IoN, A FLOIRDA COR~OP~%TI~iN, (hereinafter referred to as "Grantor"), and ~he BOARD OF COUNTY COPI~.IiSiONER$ OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO TME GOVERNING BOkRD OF ~ COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). WITNESSE TH : That said Graf. tot, for a~.d in consideration of the su~. of Dollars ($10.00) and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt of which is Grantee, and Grantee's heirs, successors and assi.oT.s forever, all water uu!lity facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and ma!ntenance of said water and sewer facilities, situate, lying and being in Collier County, Florida, to wit: (See Exhibit "A" atzached hereto and incorpora:ed by referehce herein.) . ': ." and said Grantor does hereby fully warrant ~h~ title tc said utility facilities, a-nd will defend the ss~e against the lawful claims cf all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall no~ be deemed to convey any of the lands described in Exhibit "A". Grantor and Grante~ ars used for singular or plural, as context re,aires. 2613254 OR: 2657 PG: 0335 UCO~ID in OFFICIAL ~CODS of ~LLI~I 03/30/2000 at 07:58~ D¥IG~ I. BROCK, CLK~ ~C ~1 15.00 ~C-,?0 .?0 Retn: KI~I~BilRG ~VIB¥ ~K~ICBS S~I~LI! ~II -1- OR: 2657 PG: 0336 IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. Witnesses: Print Name of Witness CARO~ ANN ~LD Print Name of Witness COAST COMMUNITIES CORPORATION A FLORIDA CORPORATION . " 'Willia~/~. Higgs, P~e~ident STATE OF FLORIDA COb-NTY OF COLLIER The yfOrego~ng instrumentof Q~.~_~ was acknowledged before me on the / da , 1999, by WILLIAM T. HIGGS, PRESIDENT, COAST~COMMITNITIES CORPORATION, A FLORIDA CORPORATION, on behalf of the Corporation. He is -~- personally known to me, or has produced as identification. Prepared by: ~' ~'~%~l°&~:i'-~ '~ NOTARY PUB~Ic ~*~ -.- }*~ Print Name of Notary Public ~.% ~cc~s ;~ MY CO~ISSION EXPIRES: Thomas E. Maloney, Esquire QU~LES & B~Y 4501 North Tamiami Trail, Suite 300 Naples, Florida 34103 QB~IAP% 183556, -2- *** OR: 2657 PG: 0337 *** Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book .32, pages (a 0.. through O I , Public Recorda of Collier County, Florida. ~xhibi: A - Legal Description Of Proper~y Form 6 - Rev. 4/28/99 (owner's Affidav~t) Utilitie~ Acce9~ance-Doc #320 STATE OF FLORIDA OWNER ' S AFFIDAVIT , 1999, befor~ me personally appeared William T. Higgs. President. Coast CDm3~unities ~orpcratio~ Florida coruoration, owner cf property to me personally kno'wn (hereinafter "Affian="), who, being duly sworn cn his oath, did say =hat all of the persons, rims, and corporations, including the general contractor and all subcontractors, who have furnished servlces, labor or material according to plans and specifications, or extra i~ems, used in the construction or repair of water and sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the Affian~ further says that no claims have been made to the Owner by, nor is any auit now pending on behalf of, any contractor, ~ubcontractcr, ia~orer or materialman, and further that no chattel mortgages or conJiticnal bills of sale have been given or are now outstanding as to the subject utility faci!itiem placed upon or installed in the ~foresaid premises. Affiant further says that the utility facilities described herein are no~ included in, encumbered by, or subjeci to any real proper~y morUgage, chattel mor5gage, security agreement, Uniform Com~.ercial Code financing statement, cr any other encumbrance, except as follows: a) Mortgage, Security Agreement and Assig~.~ent of Rents in favor of AmSouth Bank of Florida in the original principal amount of $4,100,000.00 and recorded in Official Records Book 2004, pages 1602 through 1622, as modified by Loan ~odification Agreemen5 and Notice of Future Advance Receip% recorded in official Records ~ook 2345, pages 1087 through 1099, and Second Loan ~odification Agreement and Notice of Future Advance Receipt recorded in Official Records Book 2507, pages 274 through 279, all Public Records of Collier County, Florida, and Assignment of ~ents, Leases, Profius and Contracts =o AmSouth Bank Of Florida recorded in Official Records Book 2004, pages 1623 through 1638, Public Records of Collier County, Florida. c) UCC FLnancing Statement in favor of Am$outh Bank of Florida recorded at OR Book 2004, pages 1639 through 1648, Public Records of Collier County, Florida and UCC Financing Statement filed with the State of Florida Secretary of State filed at #940000246592 on November 22, 1994. Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A". Print Name of Witness - ~ L;AI~OL ANN ANT~ELD Print Name of Witness COAST COMMUNITIES CORPOP~ATION A FLORIDA CORPORATION By: Wil~am T. ~ ident _ Subscribed and sworn to before me on the ! day of ~¢~ , 1999, by WILLIAM T. HIGGS, PRESIDENT, COAST CO[~MUNITIES CORPORATION, A FLORIDA CORPORATION, on behalf of the Corporation. He is ~~' personally known to me, or has produced as identification. NOTARY PUBLIC CAROL AI~ANTFEtn Print Name of Notary Public MY COMMISSION EXPIRES: Prepared by: QBNAP\183559.1 Thomas E. Maloney, Esquire QUARLES & BRADY 4501 North Tamiami Trail Suite 300 Naples, Florida 34103 -2- Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book ,..3~, pages ~ through Ia t , Public Records of Collier County, Florida. Form ~ - R~v. 4/25/89 Utill=~ A~fidav!=) Exhibi~ A - Description cf Real PrcperSy Exhibit B - Deed ATTORNEY'S AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLIER appeared .~Sb~s E. Ma!oney , a licensed a=torney authorized to practice in the Sta=e of Florida, to me personally known, whose current business address and telephone number is 4501Nor=h Tamiami Trail, Suite 300, Naples, Florida 34103-3060, phone # (941) 262- 5959 (hereinaf=er "Affiant"!, who being duly sworn on his oath, does say: Thts Affidavit is given as an inducement to the Board of County Commissioners cf Collier County, Florida, as the governing bo~y of Collier County and as Ex-Officlo =he Governing Board of the Collier County Water-Sewer District to accept the dedication or ccnveyanc~ of water and sewer utility facilities icca~ed within or upon the real property described in =he attached E~hibit "A", wkich is incorporated herein by reference, said land being located in Collier County, Florida. The Affiant has examined record ~£tle info~a~Sion to both the real arid personal property referenced in this affidavit, including but not limited ~o, inforr~ation requested from the Florida Secretary of State relative to any 'Uniform Commercial Code financing sta~ement~. The record owner of the real and personal property described herein is C~oast_ Co.mmunities Corporation, a Florida corporation, herelnaf~er "Owner"). The Owner acquired record title to tha s"ubJect real property by insSrument recorded at Official Records 3ook 1T99, at Page 2191, Public Records of Collier County, Florida (a copy of which is hereby marked Exhibit "B" and incorporated by reference herein). The Affiant has examined corporate information obtained from the State of Florida and such information indicates that the o Owner is current and active within Florida and is authorized to do business in Florida, and that William T. Higgs, as President of Coast Communities Corporation, A Florida corporation, is authorized to execute instruments on behalf of the Owner in conjunction with the conveyance of the subject real and personal property. The real and personal property involved in the dedication or conveyance described in Paragraph 1 of this Affidavit is not encumbered of record, nor is it the subject of any financing statements filed in the Public Records of Collier County, Florida, or the records of the Secretary of State of the State of Florida, except as follows: a) Mortgage, Security Agreement and Assignment of Rents in favor of AmSouth Bank of Florida in the original principal amount of $4,100,000.00 and recorded in Official Records Book 2004, pages 1602 through 1622, as modified by Loan Modification Agreement and Notice of Future Advance Receipt recorded in Official Records Book 2345, pages 1087 through 1099, and Second Loan Modification Agreement and Notice of Future Advance Receipt recorded in Official Records Book 2507, pages 274 through 279, all Public Records of Collier County, Florida, and b) Assignment of Rents, Leases, Profits and Contracts to AmSouth Bank of Florida recorded in Official Records Book 2004, pages 1623 through 1638, Public Records of Collier County, Florida. c) UCC Financing Statement in favor of AmSouth Bank of Florida recorded at OR Book 2004, pages 1639 through 1648, Public Records of Collier County, Florida and UCC Financing Statement filed with the State of Florida Secretary of State filed at #940000246592 on November 22, 1994. Affiant further states that the information contained in this Affidavit is true, correct and current as of .~-~- ~ WITNESSES: QBNAPl\l18812. t 2 Print Name of Witness CAROL ANN ANT, F~LD Print Name of Witness THOMAS E. MALONEY  s~cribed and sworn to before me on the / day of ...... · - , 1999, by THOMAS E. MA_LONEY, who is personally kn~n to me. NOTARY PUBliC CAROL ANN ANTFELD Print Name of Notary Public MY COM}4ISSION EXPIRES: Prepared by: Thomas E. Maloney, Esq. QUARLES & BRADY 4501 N. Tamiami Trail, Suite 300 Naples, Florida 34103 QBNAPl\l18812.1 3 EXHIBIT A Tract R, The Shores at Berkshire Lakes, Phase Two-A, according to the plat thereof recorded in Plat Book ~'~, pages OO through ~e! , Public Records of Collier County, Florida. Exhibit B - page 1 235I' ;0 OR: 2445 PG: 1698 RSCORDID in 0~EICIAL ElC01tDS of COLLISR C0U#?Y, EL 01/28/99 aL 12:I0~M D¥ISH? ]. MOC[, CLIH D0C-.?0 . 5,00 Retn: QUARLBS & BRADY 4501 TAHXAH! TR M MAPLES IL 34103 3060 This instrument prepared by an~ r~tum to: Thomas E. Maloney, Esquire { QUARLES & BRADY 4501 N. Tamiami Trail, Suite 300 Naples, Florida 34103-3060 Grantee S,S. No. Name: Coast Conununkies Corporation Property Appraiser's Parcel Idcntificat/on No. 00296080009 CORRECTIVE DEED WARRANTY DEED (STATUTORY FORM - SECTION 689.02, F.S.) THIS INDENTURE, made [his ,~' day of ...7~ I. ~' , 1998, between WILLIAM T. HIGGS, INDIVIDUALLY AND AS TRUSTEE, whose post office address is 2666 Airport Road Sou[h,,Naples, Florida 34112, Grantor*, and COAST COMMUNITIES CORPORATION, A FLORIDA CORPORATION, whose post office address is 2666 Airport Road Sou[h, Naples, Florida 34112, Grantee*, WITNESSETH that said grantor, for and in consideration of the sum of TEN AND NO/100's ($10.00) DOLLARS, and other good and valuable consideration to said grantor paid by said grantee, [he receipt whereof is hereby acknowledged, has granted, bargained and sold to the said grantee, and grantee's heirs and assigns forever, the following described real property, situate, lying and being in Collier County, Florida, to-wit: SEE ATTACHED EXHIBIT A GRANTOR HEREBY REPRESENTS AND WARRANTS THAT THE HEREINDESCRIBED PROPERTY IS UNIMPROVED PROPERTY AND IS NOT THE HOMESTEAD OF THE GRANTOR, AND THAT HE RESIDES AT 411 HENLEY DRIVE, NAPLES, FLORIDA 34104. THIS IS A CORRECTIVE DEED WHICH CORRECTS THE LEGAL DESCRIPTION CONTAINED IN THAT CERTAIN DEED DATED JUNE 22, 1998 AND RECORDED IN OR BOOK 2440, PAGES 2675 THROUGH 2677, PUBLIC RECORDS OF COLLIER COUNTY, FLORIDA. THE AFORESAID DEED (OR BOOK 2440, PAGES 2675 THROUGH 2677) ERRONEOUSLY DESCRIBED THE PROPERTY THAT WAS BEING CONVEYED AS PROPERTY DESCRIBED IN THE DEED TO WILLIAM T. HIGGS, TRUSTEE AND RECORDED IN OR BOOK 1147, PAGE 61. THE REFERENCE TO OR BOOK 1147, PAGE 61 WAS ERRONEOUS, AND THE PROPERTY DESCRIBED IN THE OR BOOK 1147, PAGE 61 DEED IS NO LONGER O¥%?ffED BY WILLIAM T. HIGG$, TRUSTEE, NOR WAS iT OWNED BY HIM ON JUNE 22, 1998. THE CORRECT LEGAL DESCRIPTION OF THE PROPERTY THAT WAS INTENDED TO BE CONVEYED IS THE PROPERTY DESCRIBED IN THE INSTANT DEED. and said grantor does hereby fully warrant the title to said land, and will defend the same against the lawful claims of all persons whomsoever. OR: 2445 PG: 1699 Exhibit B - page 2 ' IN WITNESS WHEREOF, Grantor has hereunto set grantor's hand and seal the day and year first above written. Signed, sealed and delivered in our presence: Witness gl Prat Name of..Witness # 1 Witness//2 Print Name of Witness STATE OF FLO~DA COUNTY OF COLLIER Willian~. Higgs, Individ~'l~ And/As Trustee THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME ON THE .2 ~ __ DAY OF ~e.~d~f,f ,1998, BY WILLIAM T. HIGGS, INDIVIDUALLY AND AS TRUSTEE, WHO ISTPERSONALLY KNOWN TO ME. NOTARY PUBLIC " Print Name of Notary Public MY COMMISSION EXPIRES: QBNAP\15343~.2 - 2 - Exhibit B - page 3 OR: 2445 PG: 1700 EXHIBIT A That certain 149.20 acre parcel described in Exhibit A, pages 2 and 3, which are attached hereto and incorporated by reference herein, being the same property conveyed to William T. Higgs, Trustee, by deed recorded in OR Book 1081, pages 969 through 972, Public Records of Collier County, Florida. LESS AND EXCEPT THE FOLLOWING PORTIONS THEREOF: That 38.17 acre parcel platted as Berkshire Pines, Phase 1, per plat recorded in Plat Book 29, pages 47 and 48, Public Records of Collier County, Florida. That 1.043 acre property conveyed to Collier County in that Deed recorded in OR Book 2069, page 1465, Public Records of Collier County, Florida Exhibit A - page 1 QBNAP\156753. i Exhibit B - page 4 276 lilLSON, ~ILLER. 8AR~ON. SOLL~ & PEEK.' INC. Description of 1/2 of Section 33, Township 49 South, (Ordered Co~flcifl9 a~ ~e 8ou~es~ corner of Section 33~ T~nsni~ ~u:h, ~ge 26 ZaS:, Co~%ler County, Florida; ' Section of ~o said flor~ ~Aence ~r~ 0'-07'-53' 2364.93 ~ ~ ~g[e ~gh;~[~ay O~ ~dio P~ad; %hence SO~ ~7'~43'-59' ~es: along ~e ~aid north Riqh:~-~ay, 2i00.04 fee% tO the Point of Seg[nninw 49 SOU~, ~e 26 ~S=, Collier Co~y, Con~i~9 %36.f10 acres of land ~re or ~eso. . ~naXd ~e P*L*S. t39S5 ~ce, ~u~y 6, W,O. 2~637 L_ ~xhibit A ? page 2 .Exhibit B - page 5 ' . 49 S~U~, ~e 26 EaSC, Co~ier Co~y, ~lorida and ~einy ~aid Section ~3, · distance o~ 50,04'.~eec: ~flCS conc~fluing 61onq udi~ east Ri~ac-qf-Way NotCh ' 333. ~3 ~ence c~t~uing 41on9 sa~d ~y No~ 17'-54'-5S' ease, 171~.47 ~eec: · c~e SOU~ 670- 43'-~9' ~iC, ]057.17 ~ee: ~o 49 Sou~, ~nge 26 ~at, CoI%A~c County. Subjec: ~0 eaze~nca &n~ r~::~Cti~ O~ ~cord: Con~Lqg 13.~04 acres of L~ ~:e or less, ~ce: 3u~y 11, ~.o.. 2xg~? · ' ,/* E~hib~t A - page 3 COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 ENGINEERING REVIEW SECTION September 13, 1999 Mr. Shane Parker, E.I. McAnly Engineering and Design, Inc. 5435 Park Central Court Naples, FL. 34109 Re: The Shores at Berkshire Lake, Two ~ A / a.k.a. Berkshire Pines Phase Two - A Dear Shane: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, Joh . Houldsworth Senior Engineer cc: Shirley Nix Phone (941) 403-2400 Fax (941) 643-6968 www.co.coHier.fl.us COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION January 28, 2000 Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 Shane Parker McAnly Engineering 5435 Park Central Court Naples, FL 34109 Re: Shores ~ Berkshire Lakes, Phase 2-A Dear Mr. Parker This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very~/~u/~ y~our) -- r Shirley Nix ~ Engineering ~tmician II cc~ Joe Cheatham, Wastewater Director Paul Mattausch, Water Director Diane Deoss, Public Works John Houldsworth, Engineering Review Phone (941) 403-2400 Fax (941) 643.6968 www. co.collier, fl.us McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE July 28, 1999 Ms. Shirley Nix Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 Re: The Shores at Berkshire Lakes, Phase Two-A Engineers Confirmation of Payment Dear Ms. Nix: I hereby certify that the Owners of The Shores at Berkshire Lakes, Phase Two-A have paid in full the engineering and surveying fees submitted to them by our firm. Please call me if you have any questions or require additional information. With Bes~t2Regards, McAafly]Engineering & Design, Inc. //~eilliam C. McAnly, .P.E. nior Project Engineer 5435 PARK CENTRAL COURT, NAPLES, FLORIDA 34109 MAILING ADDRESS: P.O. BOX 11717, NAPLES, FLORIDA 34101-1717 (941) 593-3299 FAX (941) 593-3298 McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE Project: HYDROSTATIC TESTING The Shore at Berkshire Lakes Project Number: 960906 Date of Test: '7/9/99 Test Pressure: 158 psi Thos~Present: Jeff Newman, Florida State Underground Shane Parker, Thomas, McAnly Engineering & Desiqn, Inc., Bob Randy Cassey, Collier County Compliance Services Description ofLineTested: 8" water main from = sta 60 + 30 to z sta 62 + 70 and 8" water main down Meridian Court CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: Power Corporation (Length of pipe) x (diameter of pipe) x SQR(test pressure) / 133200 ( 895 ii) x ( 8 in) x SQR ( 158 ( fi) x ( in) x SQR ( RESULTS OF TEST: Length of Test 2 hfs Pressure at Beginning of test: Pressure at End of test: Amount of water require to bring pressure up to beginning pressure: Test meets project specifications: Engine~ ~C. McAnly, P.E. McAnly Engineering & Design, Inc. psi) / 133200 = 0.68 psi) / 133200 = Total = 0.68 gal gal gal Allowable Leakage 1.35 gal '7: 30 am 158 psi 151 psi X YES NO Date 5/8 gal 5435 PARK CENTRAL COURT, NAPLES, FLORIDA 34109 MAILING ADDRESS: RO. BOX 11717, NAPLES, FLORIDA 34101-1717 (941) 593-3299 FAX (941) 593-3298 McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE HYDROSTATIC TESTING Project: THE SHORES AT BERKSHIRE LAKES, PHASE TWO-A Project Number: 960906.2SF Date of Test: 4/26/99 Test Pressure: 153 psi Those Present: SHANE PARKER--McANLY ENGINEERING AND DESIGN, INC. JEFF NEWMAN--FLORIDA STATE UNDERGROUND Description ofLineTested: 4350 LF 8" PVC WATER MAIN CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: (Length of pipe) x (diameter of pipe) x SQR(test pressure) / 133200 ( 4350 t%) x ( 8 in) x SQR ( ( It) x ( in) x SQR ( RESULTS OF TEST: Length of Test 2 HOURS Pressure at Beginning of test: Pressure at End of test: Amount of water require to bring pressure up to beginning pressure: Test meets project specifications: Engineer: _/~ W,i~liam C. McAnly, P.E. MeAnly Engineering & Design, Inc. 153 psi) / 133200 = 3.23 gal psi) / 133200 = 0.00 gal Total = 3.23 gal Allowable Leakage 6.46 153 gal psi ] 53 psi 0 . gal XX YES NO Date ' 5435 PARK CENTRAL COURT, NAPLES, FLORIDA 34109 MAILING ADDRESS: P.O. BOX 11717, NAPLES, FLORIDA 34101-1717 (941) 593-3299 FAX (941) 593-3298 Ic--ANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPEARCHITECTURE HYDROSTATIC TESTING Project: The Shores At BErkshire Lakes, Phase Two-A Project Number: 960906 · 2SF DateofTest: 4/26/99 TestPressure: 104 psi Tho~Prc~nt: Shane Parker-- McAnly Enqineerinq & Desiqn, Inc. Jeff Newman--Florida State Underground Description of Line Tested: 1030 LF 6" Pvc Force Main CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: (Lcngth of Pipe) x (Diamclcr of pipe) x SQR(Tcstprcssure) / 133200 1030 ft) x ( 6 in) x SQR( 104 psi) / 133200 = 0.47 ( ( fi) x ( in) x SQR( ( fl) x ( in) x SQR( ( ft ) x ( in ) x SQR( RESULTS OF TEST: Length of Test 2 Hours Pressure at Beginning of test: Pressure at End of test: psi) / 133200 = 0.00 psi) / 133200 = 0.00 psi) / 133200 = 0.00 Total 0.4 7 Allowable Leakage 0.95 104 104 gal gal gal gal gal gal psi psi Amount of water required to bring pressure up to beginning pressure: Enginccr: , . . -~)ate /'' MeAnly Engineering and Design, Inc. gal 5101 TAMIAMI TRAIL EAST, SUITE 202, NAPLES, FLORIDA 34113 (941) 775-0723 FAX (941) 775-9236 Jeb Bush Governor Department of Environmental Protection South District P.O. Box 2549 Fort Myers, Florida 33902-2549 David B. Struhs Secretary August 9, 1999 William T. Higgs, President Coast Communities Corporation 2666 South Airport Road Naples, Florida 34114 Re: Collier Coun _ty - PW Berkshire Pines Phase Two, aka The Shores at Berkshire Lakes, Phase Two Phase Two - A Completion (Collier County Regional WTP) 148774-001-DSGP Dear Mr. Higgs: This acknowledges receipt of certification that the subject water distribution system extension has been partially completed in accordance w~th the plans and related materials permitted by this agency under Permit Number 148774-001-DSGP dated December 15, 1998. Based on this certification and satisfactory bacteriological results, we are approving these facilities for service under the following conditions: If the bacteriological samples were collected prior to replacement of the temporary backflow preventer or temporary construction meter with a final connection, then additional bacteriological sampling is required. Upon completion of the final connection, collect a bacteriological sample immediately downstream of the connection and submit the bacteriological results to the Department. Immediate service can be provided if a precautionary boil water notice is issued for areas down stream of the connection, until one day of satisfactory bacteriological results have been obtained (Two consecutive days of satisfactory bacteriological results are required following any unsatisfactory result). Your continued cooperation in our water supply program is appreciated. Sincerely, Professional Engineer Water Resource Management CRD/MFJ/skw CCi William C. McAnly, P.E. Thomas E. Kuck, P.E.c...-~''' "More Protection, Less Process" Printed on recycled paper. Florida De]gartnzent of l~nvironmental 1~egulation' 'l%¥sll 'l~.)wc:rS O(fiC¢ i11(.114 e 2(~()(1131;;1~¢ Slon¢ I(oud ~ Tlll;~h3.~s¢c, Florid;~ .~2:~99.2400 Domestic Wastewater Collection/Transmission bys ems Certification of Completion of Constructio 13 ,.SOUth IX trlct INSTRUCT'IONS: This form is to be completed and submkted to the Department, prior to placing the system into operation. A collec- tion/transmtssion system should not be placed into operation without prior Department approval. All informabon is to be typed or prirated in ink and all blanks must be filled. Construction Permit No.: 52258-036-DNC Dated: 1-22-99 Name of Project: The Shores at, Berksh±re Takes (a.k.a Berksh'ire Pines, Phase 2) Name of Owner: Coast Communitites Corporation Name of design engineer and Florida registration number (if different from engineer s, gning certification): Date(s) of connection to ex~sting system or treatment plant: 4/29/99 Treatment plant serving project · Name: South Co11'ier Reg'ional WWTP County: Collier City: N'apies DER identification number (also known as GMS identilication number): Substantial deviations from the approved plans and specifications (attach additional sheets if required): Phase Two - A is 43% of the entire phase Phase Two - A consists of a qravity sewer system contain: and manhole Mlq ~34 throuqh MH ~57. This gravity system is located on sheets 10 of 18, 11 of 18, 12 of 18, 14 of f 18 3 WAIVER AND RELEASE OF LIEN UPON FINAL PAYMENT The undersigned lienor, in consideration of the final paymem in the amount of $ 1 0.0 0 , hereby received, waives and releases its lien and fight to claim a lien for labor, services or materials furnished paid by COAST COM[MUIfflTIES, CORP., Owner of the following described property: THE SHORES AT BERK~HIRE LAKES PHASE TWO 'a" BERKSHIRE LAKES, PARCEL "E' SECTION 33, TOWNSHIP 49S, RANGE 26E. COLLIER COUNTY, FLORIDA only DATED on 7128199 Lienor's Name: FLORIDA STATE UNDERGROUND, INC. By ,~ -'/"~ ~ Printed Name."' R. T. Bart Title: Assistant Secretary STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was acknowledged before me this 28 tli~ay of by R .T. Bart not take an oath. CATHYE vANKERscHAEVER Notary Public - State of Florida My comm. expires Sept 19, 2001 Comm. No. CC670403 July ,19SP , on behalf of the company who is personally known to me and did ~o~Public, State]of Florida NOTE: This is a statutory form prescribed by Section 713.20, Florida Statutes (1996). Effective October 1, 1996, a person may not require a lienor to furnish a waiver or release of lien that is different from the statutory form. COLLIER COUNTY GOVEILNMENT PUBLIC WORKS DIVISION 3301 F~ TAMIAMI TRAIL NAPLES, FLORIDA 34112 (941) 732-2575 FAX: (941) 732-2526 July 16, 1999 Florida State Underground 73 Commercial Blvd. Naples, Florida 34119 Re: Bacteriological Analysis Results - Main Clearance Attached please find the analytical results on the following water main clearance project: Shores at Berkshire Lakes Phase 2A. These results were found to be acceptable by Collier County Laboratory, #55261. Should you have any further questions regarding this matter, please contact me at (941) 352-7004. Sincerely, Howard B. Brogdon Laboratory Supervisor State of Florida Department of HeaLth Office of Laboratory Services JacksonviLle, NiamJ, Per~acole TahOe, Weat PaLm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS DHRS~ 5526~RLABUSEONLY Rec'd 13:05 7-13-99 TESTED Date: 7-13-99 By:GJG Time: 14:25 TO 15:00 CONFIRMED SYSTEM NAME: ADDRESS: Press hard, (5) copies Collier County Water Dept 5114069 732-2558 SYSTEN I.D. NO: SYSTEN PHONE #: 3301 Tamiami Trai l, Naples, FL COUNTY: Col 1 ier DISTRICT: i 1 COLLECTOR: ~_ FGI~ARNFF~ COLLECTOR PHONE #: 352-7007 SHORES I~ BERKSHIRE LAKES SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: 7-- 1 ~--qq 171c) '..~F~ TF) 1 t71 ,_ ?,171 TYPE OF SUPPLY(Circle one):~ommunity water syste~ Noncon~nunity water system Private welt Swinmning pool Bottled water Nontransient - noncommunity water system Limited Use system TYPE OF SAMPLE(Circle one): Cc~npliance Repeat Replacement ~_~in clearanc~ Well survey Other (Check Box) [ ] Distribution [ ] Check here if pay~t ~e [ ] Raw to county ptYo[ic health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE T_Q-BE COMPLETED BY LAB ANALYSIS METHO0:i~ MF~ MTF HMO-HUG PA ~'I~))~F I RM CONFIRM COLL. SAMPLE POINT C[ NON NO. (S~cific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER 1 0+00 3. 5 8. 56 ~ 990-7-302 ~ bJ .-~ J. 5 8.51 9907--303 3 60+50 3. 5 8. 51 ~ 9907--304 4 4+30 PSP 3. 5 8. 5~ /~ 9907-305 5 1+10 3. 5 8. 5.~ '~ 9907-306 6 6+20 PSP 3. 5 8. 4~ 9907-307 7 73+00 3.5 8.5~ 9907-308 I // ~ Results in this column are pres~m~otive. Total coliform and fecal coliform or E. coil confirmation will follow in 24-48 hours. p - Co[iforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): REMARKS: DAY ONE INTERPRETATIONS-REMARKS BY. PROGRAM REVIEtaER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of FLorida Department of HeaLth Office of Laboratory Services JacksonviLLe, Hi&mi, PensacoLa Tampa, West P&Lm Seach DRINKING WA TER BACTERIOLOGICAL ANALYSIS DHRS~ 55~6TORLABUSEONLY Rec'd 13:05 07-13-99 TESTED Date: 07-13-99 By:GJG 'Time: 14:25 TO 15:00 CONFIRMED SYSTEM NAME: ADDRESS: Press hard, (5) copies Collier County Water Dept 5114069 732-2558 SYSTEM I.D. NO: SYSTEM PHONE if/: 3301 Tamiami Trai I, Naples, FL COUNTY: Col 1 ier DISTRICT: 11 SHORES L~ BERKSHIRE LAKES COLLECTOR: GJ GRABNER SAMPLE SITE (LocaLity or Subdivision): COLLECTOR PHONE #: 352-7007 DATE AND TIME COLLECTED: 07- ] ~--q9 1 ~: 3~ TN 1 1 : ~% TYPE OF SUPPLY(CircLe one): <~unity water syste~ Noncon~unity water system Nontransient - noncommunity water system Private wek[ Swimming pool BottLed water Limited Use system TYPE OF SAMPLE(CircLe one): CompLiance Repeat RepLacement ~ We[[ survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE ~ COMPLETED BY LAB ANALYSIS METHOD: ~ MF~ -- ~- MMO-MUG PA COLL. SAMPLE POINT CL NON '[13N F I RM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER 8 71+50 3.5 S. 44 /~ 9907-309 9 1+30 .~. 5 8. 26 9907-310 10 9+20 PSP 3.5 6. 39 /~ 990-7-311 11 2+50 PSF' 3. 5 8. 30 /~ 9907-312 ResuLts in this coLum~ are presumptive. Total coliform and fecal coliform or E. coLi confirmation wiLL foLLow in 24-48 hours. P - CoLiforms are present C - ConfLuent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): REMARKS: DAY ONE INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of FLorida Department of Health Office of Laboratory Services Jecksonviile, Miami, Pensacota Tampa, West Pa'tm Beech DRINKING WA TER BACTERIOLOGICAL ANALYSIS DHRS~ 5526~RLABUSEONLY Rec'd 12:02 7-14-99 TESTED Date: 7-14-99 By:GJG Time: 14:35 TO 15:05 CONFIRMED Press ha~d, (5) copies Collier County Water Dept 5114069 SYSTEM NAME: SYSTEM I.D. NO: SYSTEM PHONE #: ADDRESS: 3301 Tamiami Trai i, Naples, FL COUNTY: Col i ier DISTRICT: 732-2558 11 COLLECTOR: R. RRARNFR SHORES I~ BERKSHIRE SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: 7-14-99 1 ~: ~ TR 1 ~ ~ ~A TYPE OF SUPPLY(Circle one):~nity water syst~ Noncontmunity water system Private wetL swimming pool Bottled water LAKES COLLECTOR PHONE #: Nontransient - noncommunity water system Limited Use system TYPE OF SAMPLE(Circle one): CcxnpLiance Repeat Replacement ~~ Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE CC~4PLETED BY COLLECTOR OF SAMPLE TO_BE CC~4PLETED BY LAB ANALYSIS METHO0:~'~MF~i MTF MMO-MUG PA COLL. SAMPLE POINT Cl. NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER 1 0+00 3.5 8.4c~ //Z~ 9907-329 b: b~ ,--.J ~. 5 8. 4~ 9907-330 3 60+50 3.5 8. 41 /~ 9907-331 4 4+30 F'SP 3. 5 8.4~ /~ 9907-~,-'~ .... ' 5 1+10 3.5 8. 47 /~ 9907-333 6 6+20 PSP 3. 5 8. 4~ ~ 9907-334 7 73+00 3. 5 8. 4~ ~l , 9907-335 // I Results in this column are presumptive. Total coliform and fecal coliform or E. coti confirmation will follow in 24-48 hours. P - Co[iforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Cotiforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): REMARKS: DAY TWO INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER .uZ NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: SATISFACTORY INCO~IPLETE COLLECTION INFORHATION REPEAT SAMPLES REPLACEMENT SAHPLES State of Florida Department of Hearth Office of Laboratory Services JacksonviLLe, Miami, Pensacola Tmepa, Uest Pete Beach DRINKING WATER BACTERIOLOGICAL ANAL YSIS DHRS~ 5526f°RLABusE°NLY Rec'd 12:02 07-14-99 TESTED Date: 07-14-99 By:GJG Time: 14:35 TO 15:05 CONFIRMED Press hard, (5) copies Collier County Water Dept 5114069 SYSTEM NAME: SYSTEM I.D. NO: ADDRESS: 3301 Tamiami TraL i, Naples, FL COUNTY: Col 1 ier COLLECTOR: GJ GRA~-HE R SAMPLE SITE (Locality or Subdivision): SHORES I~ BERKSHIRE LAKES DATE AND TIME COLLECTED: 07_i/:_99 19:/:~ TO !~:5~ TYPE OF SUPPLY(Circle one): L--'~oirmuni_ty water s~ Nonc~nity water system Private welt Sw~ing pool Bottled water TYPE OF SAMPLECCircle one): Compt iance Repeat 732-2558 SYSTEM PHONE #: 11 DISTRICT: COLLECTOR PHONE #: Nontransient - noncommunJty water system Limited Use system Replacement ~"~n cLearan~ Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE _TO.,rI~E COMPLETED BY LAB ANALYSIS METHO0:'~MF~ MTF MMO-MUG PA COLL. SAMPLE POINT Ct NON '-t'Olq'F ! RM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI S/I.MPLE NUMBER += . //~ 9907-336 8 71 .~0 3.5 8 41 9 1+30 3. 5 8. 44 /~ 990*7-33/ 3. 5 8. 29 //~ 9907-338 10 9+20 F'SF' 11 2+50 F-'SP 3. 5 8.00 //~ ~' 9907-339 I Results in this column are presumptive. Total coliform and fecal coliform or E. cole confirmation will follow in 24-48 hours. p - Co[iforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC- Too nu~rous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REDLa. RKS BY. PROGRAM REVIEWER REMARKS: DAY TWO NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES REVIEWING OFFICIAL: TITLE: State of Florida Department of Health Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY SYSTEM NAME: ADDRESS: COLLECTOR: Press hard, (5) copies SAMPLE SITE (Locality or Subdi%jsion): DATE AND TIME COLLECTED: TYPE OF SUPPLY(Circle one): TYPE OF SAMPLE(Circle one): SYSTEM I.D. NO: SYSTEM PHONE #: COUNTY: DISTRICT: COLLECTOR PHONE #: · Co~mmunity water system :, Noncommunity water system Nontransient - noncommunity water system Private well Swimming pool Bottled water Limited Use system Compliance Repeat Replacement Main c~eara.nce' Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE T,O.~E, COMPLETED BY LAB I ) ANALYSIS METHOD: <~F~.? MTF MMO-MUG PA COLL.I SAMPLE POINT~ CI NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER / * Results in this column are presumptive. P - Coliforms are present A - Coliforms are absent Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER o~ NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORFLATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES FLORIDA STATE UNDERGROUND, INC. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: THE SHORES AT BERKSHIRES LAKES PHASE 2-A DATE: JULY 19, 1999 THIS IS A: WATER SYSTEM XX SEWER SYSTEM ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST PVC CL150 8" 4819 LF 8.30 39,997.70 PVC CL200 8" 257 LF 10.15 2,608.55 PVC CL200 6" 104 LF 8.20 852.80 GATE VALVE 8" 15 EA 621.50 9,322.50 GATE VALVE 6" 9 EA 467.90 4,211.10 TEE 8" 5 EA 426.50 2,132.50 TEE 8"X 6" 5 EA 341.70 1,708.50 BENDS 8" 86 EA 325.60 28,001.60 BENDS 6" 5 EA 295.00 1,475.00 REDUCER 10" X 8" 2 EA 275.00 550.00 REDUCER 8" X 6" 4 EA 191.25 765.00 FIRE HYDRANT 9 EA 1,196.50 10,768.50 PERM SAMPLE POINTS 4 EA 730.25 2,921.00 BLOW OFF/VALVE & CAP 8" 1 EA 1,200.35 1,200.35 AIR RELEASE VALVE 5 EA 962.25 4,811.25 DROP CONFLICT 8" 2 EA 1,726.65 3,453.30 TOTAL 114,779.65 I DO HEREBY CERTIFY THEABOVE DESCRIBED LIST OFMATERIALS QUANTITIES OFMATERIALS, KINDS OF 3.~4 TERIALS, INCLUDING INSTALLA TION AND ALL COSTS AS INSTALLED, TO BE COMrPLETE, TRUE AND A CCURA TE AS PER FINAL PA Y ESTIM_A TE AND/OR ALL INVOICES OR STA TEiklENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRA WINGS OF THIS SY~TK3/I A S DESCRIBED BY NAME SHOWN, AS OF THIS DATE. PERSONALLY KNOWN, SWORN TO & SUBSCRIBED BEFORE ME THIS /__~.DAY OF -~1,~ ,1999 ~ /IEATHYE VANKERSCHAEVER Notary Public - State of Florida My comm. expires Sept 19, 2001 Comm. No. CC670403 CERTIFYING: j ~, PRESIDENT (SEAL) INC. FLORIDA STATE UNDERGROUND, 1NC. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: THE SHORES AT BERKSHIRE LAKES PHASE 2-A DATE: JULY 19, 1999 THIS IS A: WATER SYSTEM SEWER SYSTEM XX ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST MANHOLE 0-6 8 EA 1,058.70 8,469.60 MANHOLE 6-8 5 EA 1,257.10 6,285.50 MANHOLE 8-10 2 EA 1,567.60 3,135.20 MANHOLE 10-12 4 EA 1,969.00 7,876.00 CLEAN OUT ASSEMBLY 114 EA 88.40 10,077.60 PVC LATERAL 6" 3764 LF 9.45 35,569.80 WYE 8" X 6" 107 EA 45.20 4,836.40 SERVICE CONNECT/PLUG 107 EA 27.65 2,958,55 PVC 0-6 8" 2039 LF 13.50 27,526.50 PVC 6-8 8" 681 LF 16.00 10,896.00 PVC 8-10 8" 733 LF 23.00 16,859.00 PVC 10-12 8" 83 LF 27.00 2,241.00 PVC F/MAIN CL150 6" 972 LF 9.40 9,136.80 PVC F/MAIN CL200 6" 89 LF 10.90 970.10 BENDS 6" 10 EA 261.50 2,615.00 LIFT STATION 1 EA 44,300.00 44,300.00 AIR RELEASE VALVE 1 EA 1,175.00 1,175.00 TOTAL 194,928.05 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OFMATERIALS, QUANTITIES OFMATERIALS, KINDS OF MATERIALS, INCLUDING LVSTALLA TION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFTING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERT~IFIED RECORD DRAWINGS OF THIS SYSTEMAS DESCRIBED BY NAfl4E SHOWN, AS OF THIS DATE. PERSONALLY KNOWN, SWORN TO CERTIFYING: & SUBSCRIBED BEFORE ME THIS /J~ DAy OF ~/ ,1999 "'//'_/~,// ~7/ ~ /' FLORIDA ST~UNDERGROUND, INC. (NOTA~ PUBLIC NA1QIE & SEAL) CATHYE VANKERSCHAEVER Notary Public - State of Florida My comm. expires Sept 19, 2001 Comm. No. CC670403 McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE July 28, 1999 Mr. Tom Kuck, P.E. Senior Project Manager Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 Re: The Shores at Berkshire Lakes, Phase Two-A Water and Sewer Utilities Acceptance Dear Mr. Kuck: The purpose of this letter is to certify that all water and sewer facilities required for acceptance of the above development are located within the dedicated Right-of-Way or dedicated utility easements. With Best Regards, McAnl~,i~,ee~j~ & Design, Inc. / illiam C. McAnly, P.E. Senior Project Engineer 5435 PARK CENTRAL COURT, NAPLES, FLORIDA 34109 MAILING ADDRESS: P.O. BOX 11717, NAPLES, FLORIDA 34101-1717 (941) 593-3299 FAX (941) 593-3298 July 19, 1999 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 34112 WATER DISTRIBUTION SYSTEM "THE SHORES ~ BERKSHIRE LAKES PHASE 2-A" Parcel "E" Section 33, Township 49 South, Range 26 East Collier County, Florida. Commissioners: This letter is to certif, y the completion of the WATER DISTRIBUTION SYSTEM located within the above referenced property. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier County Board of Commissioners. Sincerely, President TPM/mkm 73 COMMERICAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891 July 19, 1999 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 34112 SEWER DISTRIBUTION SYSTEM "THE SHORES ~ BERKSHIRE LAKES PHASE 2-A" Parcel "E" Section 33, Township 49 South, Range 26 East Collier County, Florida. Commissioners: This letter is to certify the completion of the SEWER DISTRIBUTION SYSTEM located within the above referenced property. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier Count); Board of Commissioners. Sincerely, ~ Tl~oma-g~P:- Mc/Kt~ President ~ 73 COMMERICAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891 Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt ITrans Number I Date 158053 i 10/0471999 1:08:14 PM ~ 1010411999 Pmt Slip # Status UT-60372 POSTED FLORIDA STATE UNDERGROUND BROOKSHIRE PINES UNDERGROUND WO 18170, DOR 498 Payor · FLORIDA STATE UNDERGROUND INC Fee Information Fee Code / Description l GL Account Amount Waived 42CYIN ~ COUNTY INVOICES ~ 40800000011510000000 $560.12 Total $560.12 Payment Code CHECK Payments Account/Check Number ~220~ ...... Memo: FLORIDA STATE UNDERGROUND 73 COMMERCIAL BLVD NAPLES, FL 34104 $560.12 j Total Cash Total Non-Cash $0.00] $560.12 $560.121 Total Paid Cashier/location: TERILLA J / 1 User: FOGLE C Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:02/16/2000 11:09:22 AM Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt [ Trans Number Date i ipoS~I Date I 1_~8_054 ...... 10/04/1_9~9 __'1_: 0_8_ :~4 P_~ .... ~10/04/1999 Pmt Slip # Status UT-60377 POSTED FLORIDA ST. UNDERGROUND THE SHORES 2 BERSHIRE LAKES DOR 541, WO19052 Payor · FLORIDA STATE UNDERGROUND INC Fee Information tFee Code Description 42CYIN 40800000011510000000 Amount COUNTY INVOICES $60.79 Total $60.79 Waived Payments PaymentCHECK Code Account/Check Number Amount 22297 $60.79 Memo: FLORIDA ST. UNDERGROUND 73 COMMERCIAL BLVD NAPLES, FL 34104 Total Cash $0.00 Total Non-Cash $60.79 Total Paid I $60.79 i Cashier/location: TERILLA_J / 1 User: FOGLE C Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:02/16/2000 11:09:34 AM GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-6901 (941) 455-2121 · FAX (941) 455-7917 July 27, 1999 Mr. Shane Parker McAnly Engineering and Design, Inc. P.O. Box 11717 Naples, Florida 34101 - 1717 Dear Mr. Parker: Subject: Shores at Berkshire Lakes Phase IIA Please accept this as notification that the Golden Gate Fire District will not accept ownership or maintain the fire hydrants after their installation in the Shores at Berkshire Lakes development. Sincerely, Donald R. Peterson Fire Chief DRP/pm RECEIVED Jill 29~999 McANLY ENGINEERING AND DESIGN, INC. 1111111111 ~p. 10 19c3~ 08:4o_~1F~ GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-690'1 (941) 455-2121 ,, FAX (941) 485-7917 September 8, !999 MeAnly Engineering And Desi~ Inc. P.O. Box 11717 Naples, Florida 34101-1717 Dear Mr. Parker Subject: I-[_vdrant Flow Tests - '['be Shores. On ~ber 3, 1999 the Golden Gate Fire Control & Rescue Di~ricl did a flow test on (9) hydrants in Thc Shores, Phase IIA projeeL The results are: Hydrant 33492653 - Lot 4 72 Static PSI 56 Residual PSI 54 Pilot Flow PSI 2330 GPM at 20 PSI Residual Hydrant 33492654 - Lot 29. Wexford Dr. 72 Static PS1 56 Resid~ PSI 50 Pilot Flow PSI 2241 OPM at 20 PSI Residual ~vdrant 3:M~655 72 Statio PSI 56 Residual PSI 50 Pitot Flow PSI 2241 GPM at 20 PSI Residual 09-10-1~39 0~: 3BAM 1111111111 P. 02 : 1111111111 ~ep. 10 1999 0B:491~ F3 Shan¢ Parker MeAnly Engineering And Design, Inc. Page 3 September 8, 1999 Hydrant 33492661 - Santa Barbara Blvd. & Berk,~hire Pines_ PI. 72 $'ta~¢ PSI 62 R~idual PSI 58 Pitot Flow PSI 3113 GPM at 20 PSI Resid~ Before completion of the projec% thc hydrants necd to be painted OSHA safety yellow. The caps need to be painted OSHA safety Ught blue. Also, blue road rejectors need to be installed to show location of all hydrauts. This Fire District does not accept ownership nor does it mi~in fire hyd.mms aP, er their installation. Total due the Oolden Gate Fire Control District for the nine (9) flow tests is $315.00. Sincerely, Donald IL Petctson Fire Chief DRP/pm Ertclosures 09-10-1999 ~:~g~l 1111111111 FROM : "= PHONE NO. : 1111111111 S~p. 10 1999 08:5~AM P4 Golden Gate Fire Department Hydrant Flow Tests by Hydrant Number Hydrant Number equal to "33492653" LOT 41 EECESTER CT 33492653 AM DARUNG AWWA Date/Staff Static Reaid .. Pitot ,Pitot 2 GPM ~.20 psi . ~10 psi ~ 0 psi 09/03/1999 72 56 54 0 1233 2330 2562 2778 j..q .................. .N..aJ..~..n., _g.~.e.y..J!.~.R. !..~,.,, .P~ N_ .G! _N..E_ ~B. ........................................................................ Subtotal Tests: I Max: ¶233 2330 2562 2778 Min: 1233 2330 2562 2778 A~I: 1233 2330 2662 2778 Total Row Te~ts: I 09/0711999 12:55 Page 1 ~9-10-1999 08:3~)AM 1111111111 P.04 Fl:~. : "= PHONE HQ. : 1111111111 ,Sep. 10 Golden Gate Rre Department Hydrant Flow Tests by Hydrant Number Hydrant Number equal to '33492654 LOT 29 WEXFORD DR 334926B4 AM DARLING AWWA Date/Staff Static Resid ,Pitot Pitot 2 GPM g~20 prd ~10 psi ~ 0 ps{ 09/0'3/1999 72 56 50 0 1186 2241 2465 2672 .~..o. ................ N**e.!.s.o**n.,.._.Cf~.**.y. J/O**R.!..V~.....R~***N..~!.Ng_E. R ....................................................................... Subtotal Tests: I Max: 1186 2241 2466 2672 Min: 118~ 2241 24&B 2672 Avg: 1186 2241 2A6~ 2~72 Total Flow Tests: 1 09/07/1999 13:29 0~- 10-19c3~ ~:3C~M 1111111111 P.~5 ~OM : .= ~I~ MO. : 1111111111 Golden Gate Fire Department Hydrartt Flow Tests by Hydrant Number Hydrant Number' equal to "33492661 SANTA BARBARA BLVD & BERKSHIRE PINES 334-.9266 t AM DARUNG AWWA I~;dS[a;; I~L ~___;~J'_C Resid Pitot Pitot 2 GPM ~20 psi . ~;0 psi , ~ 0 psi Subtotal Tests: I Max: 1278 3113 3423 3711 Mtn: 1278 3113 3423 3711 Avg: 1276 3113 3423 3711 Total Flow Tests: I 0910711999 13:41 Page ~9-10-1999 08:5~AM 1111111111 P.06 ',AN LY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE Project: The Shores EXF ~ILTRATION TESTING at Berkshire Lakes, 2A Project Number: 9 6 0 9 0 6 Dat~ of Test: Those Present: 6/24/99 R. Shane Parker, E.I., McAnly Enqineerinq and Desiqn Willard Henderson, McAnly Engineering and Design John Henderson, McAnly Enqineerinq and Design DescfiptionofL~eTest~: Gravity sewer system consistinq at manholes: MH % 34 through MH ~ 51 CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: (Length of pipe) x (diameter of pipe) x SQR(test pressure) / 133200 (( 3169 It)/ 5280it) x ( 8 in) x 50 (( 2597 It)/ 5280 It) x ( 6 in) x 50 (( It)/ 5280it) x ( in) x 50 RESULTS OF TEST: Length of Test 24 hours Calculation of Actual Infiltration: Allowable Leakage gal/day = 2 4 0.1 gal/day = 14 7.6 gal/day = Total = 3 8 7.7 387.7 67.7 gal gal/day gal/day gal/day gal/day gal Test meets project spccifications: X YES McAnly Engineering & Design, Inc. Date NO 5435 PARK CENTRAL COURT, NAPLES, FLORIDA 34109 MAltING ADDRESS: P.O. BOX 11717, NAPLES, FLORIDA 34101-1717 (941) 593-3299 FAX (941) 593-3298 FROM : FLORIDA STATE ~OLIqD INC. PHONE NO. ' 941 ~43 6891 Jun. ~4 1999 07:3~AM P2 Tlle Finest irt Wastewater St,wcture Rei~bilitation!'~~d~ .._~._,. ~.ckmbJe, c'o~c-"d, on the ~,.tt~. with Carl A. L~lui~l~ra ~ ! ~6-24-1999 W?:L:~ 941 643 6891 P.02 FROM : FLORIDA STATE UNDE~GRO~--'INC. PHONE NO. : 941 643 6891 '-~ Jun. iS i999 iO:52AM P2 BAY ELECTRIC OF COLLIER, INC', OQMPLET~. ~ZRVlI~[ & IldiTAU. ATK)N 5/99 VOLTAGE FULL LOiDt ~20/34o VOLTAGE DIOF~ 0 VOL?AGE DROP WITH ~a 52 AS PER NATIONAL ELECTRZ~ CODK 06-15-1999 10:45AM 941 643 6891 P.02 DIVISION OF ELLIS K. PHELPS & CO. [] 2152 SPRINT BLVD. APOPKA, FL 32703 (407) 886-3131 5661 DIVISION DRIVE FORT MYERS, FL 33905 (941) 693-5226 RESPOND TO: [] 1100 53RD COURTSOUTH MANGONIA PARK WEST PALM BEACH, FL 33407 (561) 848-2299 PUMP STATION START-UP REPORT [] 124 AIRPORT PARK DR. SAVANNAH, GA 31408 (912) 966-1866 Collier County JOB NAME THE SHORES @ BERKSHIRE LAKES OPERATOR LOCATION OF INSTALLATION __Naples, FL CONTRACTOR FLORIDA STATE UNDERGROUNDESIGN CONDITIONS: GPM TDH PUMP MODEL CP3102 H.P. 4 IMPELLER~ 436 VOLTAGE 230 PHASE ~ SERIAL NUMBER #1 180-9910406 #2 180-9910532 ~3 ~4 MANUFACTURER OF CONTROL QCI SERIAL # 12-98-24 OVERLOAD HEATER # B-25 L/A CONNECTED YES GROUND CONNECTED ALTERNATOR TESTED YES YES COMMENTS: MEGGER CHECK #1 INF %2 INF %3 %4 RED INF BLACK INF WHITE RED INF BLACK INF WHITE RED BLACK WHITE RED BLACK WHITE TO GROUND VOLTAGE CHECK: CONTROL CIRCUIT PRIK~RY 125 A to B 249 B to C XX A to G 125 B to G 125 AMPERAGE CHECK: ~1 15 A 15 B XX %2 17 A 17 B XX ~ A B PUMPS SEATED PROPERLY YES SECONDARY A to C XX A to G XX C PHASE C PHASE C PHASE 26 FIELD TEST PERFORMANCE TEST: 91 313 GPM 33 TDH #2 ~3 GPM TDH ~4 I certify this report to Official Start-Up Date: OPERATOR HAS RECEIVED INSTRUCTION MANUAL YE___~_S 330 GPM 30 .TD~BOTH //,~M____-----TDH be accurate :,~~/~' '~~//~ 6/15/99 DATE OF REVIEW: PROJECT NAME: COLLIER COUNTY UTILITIES W~STE~ATER DEP~RTMENT PROJECT VIDEO REVIEW 6-1-99 Shores @ Berkshire Pines, Phase Two (South) ENGINEER OF RECORD: CONSTRUCTION CONTRACTOR: VIDEO CONTRACTOR: Sewer Viewer COMMENTS: Lines and services acceptable. RECOMMENDATIONS: ~---~-~ACCEPTABLR: ~-~ REVIEW NUMBERED COMMENTS IN ONE YEAR: ~-----~NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) ~ OTHER RECOMMENDATIONS: J U N r~ ,~ 1999 RECE!VED ,JUN 0 ~ 1999 WASTEWATER DEPARTMENT COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 July 21, 1999 Mr. Shane Parker McAnly Engineering & Design P.O. Box 1171 Naples, Florida 34104-1117 RE: The Shores ~ Berkshire Phase 2-A, Water & Sewer Dear Mr. Parker: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on July 21, 1999. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to c~l[' Randy Casey at (941) 403-2418 or Clyde Fugate at (941) 403-2417. Sincerely, Engineering Inspections Supervisor CF/taa/fi\Inspection form water & sewer cc: Cindy Erb, Engineering Technician, Public Works Joe Cheathan, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section File Phone (941) 4~-2400 Fax (941) 64~1-6968 www. co.coilier, fl.us