Loading...
Cedar Hammock ClubhouseMEMORANDUM DATE: February 26, 2000 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II / Project Plan Review RE: Cedar Hammock Clubhouse Water and/or Sewer Facilities Acceptance Recording Fee Number 113-138312-649030 On /~/ /~ , /-99~The Board of County Commissioners grant~d/final acceptance of ~he water and/or sewer facilities within the above-referenced project· Attached, please find the following recorded, in order: 1. Bill of Sale '2. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files· Copy of preliminary approval letter from Engineering Review Copy of Letter of Credit accepted for maintenance Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities DER Placement-in-Service letter for sewer facilities Contractor'S Final Release of Lien Lab results on bacteriological test for water lines Memorandum to Maureen Kenyon, Supervisor, Clerk to Board February 26, 2000 Page Two 11. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 12. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 13. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 14. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 15. Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing 16. Copy of backflow prevention assembly test report 17. Certification of the inflow/infiltration test for the sewer lines by Engineer of Record 18. Copy of video tape test report 19. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations if you have any questions, please call and advise accordingly. attachments doc:2094-2 ~> ~t~ r--.I m-<: '0 0.. £r- ~.~ 0'-C-q t-O t-O ~1 Ltl ,Lq 0 ,~, 0 10 0 0 0 0 C] [Iq rrl ITl I-4 Z ITl ITl O"J Z n] ! C, 0 m Om Z Z "no~ m-I m Z ,C, ,C, C, II II II 11 il II II Il tl 11 11 II Il II il II Il II II II II II II 11 II tl II m 2613465 OR: 2657 PG: 0881 BILL OF SALE THIS BILL OF SALE evidencing the sale and conveyance ofthe water and sewer utility facilities described herein is made this 10Lb day of January ., ::111200.___9_0, by CEDAR HAMMOCK COMMUNITY DEVELOPMENT DISTRICT DISTRICT OFF1CES 210 N. UNIVERSITY DRIVE, SUITE 301 CORAL SPRINGS, FLORIDA 33071 (hereinafter referred to as "Seller"), to the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). WITNESSETH: The said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and oth6r good and valuable consideration to said Seller in hand paid by said Buyer, the receipt whereof is hereby acknowledged. has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant bargain, sell, transfer, set over and deliver unto the Buyer, and Buyer's heirs, successors and assigns forever, all those certain [identify type of utility facilities by inserting water, or sewer, or water and sewer] utility facilities lying within the following described land, together with appurtenant easement rightg for the operation. installation and maintenance of said facilities, situate, lying and being in Collier Count,./, Florida, to wit: (See Exhibit "A" attached hereto and incorporated by reference herein.) OR: 2657 PG: 0882 .The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good fight, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. IN WITNESS WHEREOF, the Seller has caused these presents to be executed tEz date and year first above written. Witness t'~~ ~'~ STA~ OF FLO~DA CO~ OF COLLIER By: Peter R. Comeau Chairman - Board of Supervisors The foregoing Bill of Sale was acknowledged before me by ~ ~:~.-D P't,.-tt~-t T ,0t~ ~~OP'-~ , on behalf of the corporation. Personally known to me or produced identification. Type of identification produced: WITNESS my hand and official seal this __ day of x-~e~ Ix3 I..L,a-e-~t , ('~y C~mmission Expires: Prepared By: BANKS ENGINEERING, INC. 2150 GOODLETTE ROAD, SUITE 701 NAPLES, FLORIDA 34102 *** OR: 2657 PG: 0883 *** EXHIBIT "A" All water and sewer utilities are located within the platted Right- of-Way or CUE's as shown on the plat of Cedar Hammock (Plat Book 32, Pages 91-108) as recorded in Collier County Public Records. IR~IHIRIIG H¥IH $IRVlC~$ RIX '/.613466 OR: 2657 PG: 0884 HCOR~I~ in the OUICI~ HCO~D$ o[ C0ttlaR ¢0~R~L ~t 03/30/2000 at 09:33XN DWIG~ I. BROCK, C],IRR WARRANTY DEED DeC-.TO 15.00 .TO THIS INDENTURE made this ~0~h day of Jammry ,~]920u0, between CEDAR HAMMOCK COMMUNITY DEVELOPMENT DISTRICT DISTRICT OFFICES 210 N. UNIVERSITY DRIVE, SUITE 301 CORAL SPRINGS, FLORIDA 33071 (hereinafter referred to as "Grantor"), to the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFiCIO THE GOVERNING BOARD OF THE COLL1ER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). WITNESSETH: The said Grantor, for and in consideration of the sum ofTen Dollars ($10.00) and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: (Sec Exhibit "A" attached hereto and incorporated by reference herein.) and said Grantor does hereby fully warrant the title to said utility facilities, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A." Grantor'and Grantee are used for singular or plural, as context requires. TO HAVE AND TO HOLD the same unto the Grantee and its assigns, together with the right to enter upon said land, excavate, and take materials for the purpose of constructing, operating, and maintaining utility £acilities thereon. Grantor and Grantee are used for singular or plural, as the context requires. IN WITNESS WHEREOF, the Grantor has caused these presents to be executed the date and year first above written. STATE OF FLORIDA COUNTY OF COLLIER By: Peter R. Comeau Chairman - Board of Supervisors The foregoing Warrant Deed was ackno, ledged before me by /[5~---'l~-~.- ~ .(,~l~ , '~-'~O~T '/~TF~C.T , CF ~ I P~A..qDI~,. on behalf of the corporation. Personally known to me or produced identification. Type of identification produced: o WITNESS my hand and official seal this ilf. T~'c'... .Y~t~ l! !1%':,'?....?: ~: ~te, am I[ .. IL,""".:::""' (Affix Notary Seal) Prepared By: BANKS ENGINEERING, INC. 2150 GOODLETTE ROAD, SUITE 701 NAPLES, FLORIDA 34102 *** OR: 1657 PG: 0886 *** EXHIBIT "A" All water and sewer utilities are located within the platted Right- of-Way or CUE's as shown on the plat of Cedar Hammock (Plat Book 32, Pages 91-108) as recorded in Collier County Public Records. COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION February. 3, 2000 Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 Tony Squitieri Banks Engineering, Inc. 2150 Goodlette Rd. #701 Naples, FL 34102 Re: Cedar Hammock Clubhouse Dear Tony: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board' s desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, Shirley NYX Engineering Technician II CC-' Paul Mattausch, Water Director Diane Deoss, Public Works Phone (941) 403-2400 Fax (941) 643-6968 www. co.collier, fl.us FIDELITY GUARANTY AND ACCEPTANCE CORP. Box 2863, HOUSTON, TEXAS 77252-2863 (713) 599-2575 IRREVOCABLE STANDBY LETTER OF CREDIT NO. 00005 ...... ,- - ~,'._ .~_~-,M'~ .:... - . ~ ..~=-~a ~.:: ,~ '_-:~;' ;-,4;~,.; - .-Z.-~K:-~.~L;[-~.~C~:' ~ L~;_~¥',~c3kJA~ANTYANDAGCEFrI-ANC~ DA~ OF ISS~: J~Y 14, 2~ PEA~ OF~Y: AT ISS~'S C~~ ~ _.' _ . , .. ~ - . . ~' ' S~E~'~~'PE~~ ~ IS8~ ~ESS AT LE~T SI~ (~) DAYS P~OR TO ~RS~Y DA~; ~ ISS~R~'8 ~T~G BY ~IS~D ~ ~T ~ ISS~R EL~ N~'~ A~~ TO ~ BUS--SS ~ ~ STA~ OF ~O~A (~~R "~P~C~") 1~91 ~ ~ C~8 P~~, FORT ~, ~ 33912 ..... c~~;,'.. .... '.,:: $1~3~,16:~g~,~O ~'A~~ ~~ PA~ AG~ST ~~$ DET~ ~CT;'~' sATIsFACTORY ~~AT~'P~o~CE SEC~TY PRO~ED TO ~ FOLLY ACCEP~D BY ~ BE~FICI~Y." U.S. HO~ CO~O~ON C~D~ NO. ~5 DAT~ I~Y 14, 2~." ~ O~G~ LET~R OF C~DIT ~N~ ~L ~~S, · ~, ~ST BE P~SEN~D FOR PROPE~ ' E~RSE~NT. ~S LE~R OF ~D~ SETS FOR~ ~ ~ ~ ~S OF ~ ISS~'S ~T~G ~ SUCH ~ERT~G ~L NOT ~ ~ WAY BE MOD~mD, AG~E~ ~~CED TO ~ OR'~ ~ ~S LE~R OF C~IT ~LA~S, ~ ~ SUCH ~~CE S~IJ. NOTBE D~D TO ~CO~O~TE ~N~ ~ ~~, ~S~~ OR AG~E~. ~SSUER ~y ENGAGES WITH BENEFICIARY THAT D!~., T(S) DRAWN UNDER AND IN~ COM~'HA~CE wrrH TH~ T~,~S' OF 'THtS CAEmT' winL ~' t~OLY'~IONORED ~¥ ]S S~I~ PRESENTED WITHIN THE VALIDITY OF THI. S CREDIT. ..THIS Cg~._I]~_'IS_ S...LI~m..C~_ TO THE UNIFORM CUSTOMSAND P1LACTICE FOR ~~"~ :' ,C; S::~' '- ' '- · - ~' ~ ' -~' '~'-~- C ~ ,.; ,%' ~ ~hC' ~.,,~;- '~'~L:~ ~R~~ ~ L bu. ~A?~ -" A;,.D A~GE: :NCE CC, R~: :U~.,T'F GUAR~ANDA~EPT~C~ ~DA'.-- - A~[j AC~DTAN~- .]~.D~- ~ ~ ' ~%" ?..2 ',::'.L-~:~'.Z:': L'?R-~ :: ~2T. '~ GIJAKA,uTv AND ACC':: · '~C~ CFF. P - {}EL~TY GIJARA~ANDA~EPTANCE - . a...-._ '-.~,, .? ..... :. -]~-;' - --: '~ -_ '_ -'- '- A",C :.:',F'~,~C:; '"';~.;:',' GUARAN~ AND ACCEPTANCE Professional Engineers, Planners & Land Surveyors January24,2000 Collier County Board of County Commissioners Collier County Government Complex 3301 East Tamiami Trail Naples, FL 34112 Reference: CEDAR HAMMOCK - CLUBHOUSE - SDP 99-152 FINAL PAYMENT CONFIRMATION Ladies and Gentlemen: We do hereby certify that no outstanding money is owed to us for engineering fees at this time associated with the design and certification of the water and gravity sewer systems at the above project. Sincerely, BANKS ENGINEERING, INC. David R. Underhill, Jr., P.E. Florida Registered Engineer #47029 DRU/jmp S:\Reception~Letter~\12xx\1263\County\Clubhouse\Clubhouse Utility Tumover\1263_FinalPaymentConf-Clubhouse.wpd Lee County: 10501-104 Six Mile Cypress Parkway, Fort Myers, Florida 33912 · (941)939-5490. Fax (941)939-2523 Collier County: 2150-701 Goodlette Road, Naples, Florida 34102 (941)403-8866 Fax (941)403-8868 ngineerin!3, Professional Engineers, Planners & Land Surveyors January24,2000 Collier County Board of County Commissioners Collier County Government Complex 3301 Tamiami Trail East Naples, Florida 34112 Reference: CEDAR HAMMOCK - CLUBHOUSE - SDP 99-152 PRESSURE TESTING CERTIFICATION Ladies and Gentlemen: We witnessed pressure testing on the potable watermain and fire main on December 15, 1999, per the standards set forth in the Collier County Utilities Ordinance. The test results are as follows: 1. Potable Watermain; Start: 9:00 a.m. ~ 155 psi Finish: 11:00 a.m.~ 155 psi No leakage was observed. Total Length Tested = 195 Feet (8") Allowable Leakage = N/A Gallons Amount Required to Re-establish Test Pressure = N/A Gallons Fire Main; Start: 9:00 a.m. ~ 205 psi Finish: 11:00 a.m. ~ 205 psi No leakage was observed. Total Length Tested = 255 Feet (4") Allowable Leakage = N/A Gallons Amount Required to Re-establish Test Pressure = N/A Gallons We do hereby certify that the watermain and fire main have passed pressure testing as set forth by Collier County Utilities Ordinance. Sincerely, BANKS ENGINEI~RING, INC. David R. Underhill, Jr., P.E. Florida Registered Engineer//47029 DRU/jmp S \Reception~Lerters\l 2xx\1263\County\Clubhous¢\Clubhouse Utility Turnover\1263_PressureTesl-Clubhouse,wpd Lee County: 10501-104 Six Mile Cypress Parkway, Fort Myers, Florida 33912 · (941)939-5490 · Fax (941)939-2523 Collier County: 2150-701 Goodlette Road, Naples, Florida 34102 ' (941)403-8866 · Fax (941)403-8868 Jeb Bush Governor Department of Environmental Protection South District P.O. Box 2549 Fort Myers, Florida 33902-2549 David B. Struhs Secretary January 12, 2000 Peter R. Comeau, Regional Vice President U.S. Home Corporation 10481 Six Mile Cypress Parkway Fort Myers, Florida 33912 Re: Collier County - PW Cedar Hammock - Clubhouse (Collier Countv Regional WTP) 163189-001 -DSGP Southwest Coast EMA Dear Mr. Comeau: This acknowledges receipt of certification that the subject water distribution system extension has been completed in accordance with the plans and related materials permitted by this agency under Permit Number 163189-001-DSGP dated December 21, 1999. Based on this certification and satisfactory bacteriological results, we are approving these . facilities for service. Your continued cooperation in our xvater supply program is appreciated. S~n~rely, Charles R. Davault/-l'~* Professional Enginee~ Water Facilities CRD/MFJ/skxv CC: /David R. Underhill, P.E. Thomas E. Kuck. P.E. "More Protection, Less Process" Pr/nted on recycled paper. Florida Department of ,nvJronmGllta] Protection DOMF~TIC WASTEWA'rER CO~._!_.FCTIONfTRANSMI~ON SYSTEMS CERTIFICATION OF CO~ON OF CONSTRUCTION INSTRUCTIONS: TI~ form is to be cc,~iAet~d and submitted so the ~z, prim' to plneini the sYmnn into operation. A collection/imperils, ion sys~n should not be placed into operatio~ wid~ut prior Department approval. All ~,'~ is to be typed or prinu~d in ink ami ail blanks must be filled. Construction Permit No:' 5225g-074-DWC-~*L Narn~ of Project Cedar H~vrmcl~ - Name of Owne~: U.S. Home Dated Na~e of design engineer and Florida regisu~on ,~umber (if diffem~ from mgiaeer sia;ning cenif~ion): Da~(s) connec~on to ~ti.~in~g sys~m or trram~t plaut: Treaunent plant servi~ projoct Nan,: South Cottony DF.P ~n Number (also known as WAFR or GMS Identification Subs2nthl dev~o:~ f~xn thc approvcd plans and Sl:~'ff. zcafions WAIVER AND RELEASE OF LIEN UPON FINAL PAYMENT The undersigned lienor, in consideration of the final payment in the amount of $ -0- , hereby waives and releases its lien and right to claim a lien for labor, services or materials furnished to (customer) U.S. HOME ODRP. on the job of (owner property) CEDPaR ~ , to the following described property: CEDAR HAMMOCK CLUBHOUSE. 1-12 2000. Dated On ,:l~ Mitchell & Stark Const. Co., Inc. kienor's Name 6001 Shirley St. Address Naples, FL 341 09 Brian Penner P,'inted N:,me NOTE: This is a statuto~, forfn prescribed by Section 713.20, Florida Statutes (1996). Effective October 1, 1996, a person may not require a lienor to furnish a waiveF or release of lien that is different from the statuto~, form. COLLIER COUNTY GOVERNMENT PUBLIC WORKS DIVISION 3301 E. TAMIAMI TRIAL NAPLES, FLORIDA 34112 (941) 732-2575 FAX: (941) 732-2526 January07,2000 Mitchell and Stark 6001 Shirley Street Naples, Florida 34109 Re: Bacteriological Analysis Results - Main Clearance Attached please find the analytical results on the following water main clearance project: Cedar Hammock Clubhouse. These results were found to be acceptable by Collier County Laboratory, #55261. Should you have any further questions regarding this matter, please contact me at (941 ) 352-7004. Sincerely, , Howard B. Br6gdon Laboratory Supervisor State of FLorida Department of Health Office of Laboratory Services JacksonvilLe, #i~.i, PensacoLa Tampa, West PaLm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS LAB USE ONLY Press hard, (5) copies · .~ .. ~. : £.:..;- _. ? ~."": *,~: :;,. SYSTEM NAME: ADDRESS: COLLECTOR: ~":~ E!~ ~.',~j?d~v~. ~ SAMPLE S[TE (LocaLity or Subdivision): DATE AND TIME COLLECTED: t~--~L ...... ~.i TYPE OF SUPPLY(CircLe one): C(~C~oo~ni ty water s~stem~ SYSTEM I.D. NO: SYSTEM PHONE #: ...... COIJNTY: DISTRICT: .... COLLECTOR PHONE #: - ~ ~:: ~!~:~"!: ,~fi~i:l' - ..... J':':-2,_ :_..ii.i Noncommunity water system Nontransient - noncoff~aunity water system Private well Swimming pool BottLed water Limited Use system TYPE OF SAMPLE(CircLe one): CompLiance Repeat Replacement ~Main clearanc~ WeLl survey Other (Check Box) P-]-Oistribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO_BE COMPLETED BY LAB ANALYSIS METHOD: fMF~ MTF HMO-MUG PA COLL. SAMPLE POINT C[ NON 'L~OI~FIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * ResuLts in this column are presun~otive. Total coliform and fecal :oliform or E. co[i confirmation wiLL foLLow in 24-48 hours. p - Co[iforms are present C - ConfLuent growth TA - Turbid, Absence of gas or acid A - Cotiforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address beLou): ~:~'"':!'~::.~: !Ji~~ 'iim~i INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCC)MPLETE COLLECTION INFOR~LRTION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of FLorid. Department of HeaLth Office of Laboratory Services JacksonviLLe, Miami, PensacoLa Tampa, Weat PaLm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS -. ,."~=,~} :3%'~ LAB USE ONLY TESTED Da~e~ i ~-~-~ By:ROD ' CONFIRMED SYSTEM NAME: ADDRESS: COLLECTOR: SAMPLE SITE (LocaLity or Subdivision): DATE AND TIME COLLECTED: i~--~--~9 TYPE OF SUPPLY(CircLe one): Press hard, (5) copies Coi Iier County Water Dept 5114069 SYSTEM I.D'. NO: SYSTEM PHONE #: =30! *Tam;am; T'rai', Na~le5, R. 0' DDNNELL. COLLECTOR PHONE #: CEDAR ..... ~.h .. .........CLUBHOUSE TYPE OF SAMPLE(CircLe one): ~nit¥ water sys~ Nonco~nunity water system Nontransient - noncoamJnity Mater system Privat6 ~et[ S~in~ning poD[ Bott[~ ~ate~ Limited Use syst~ C~[iance Re,at Reptac~nt ~n c[eara ~e[[ survey Other (Check Box) ~ Distri~tion ~ [ ] Check here if ~nt ~de [ ] Ra~ to county ~bLic health uni TO BE COMPLETED BY COLLECTOR OF SAMPLE ~i~E COMPLETED BY LAB ANALYSIS METHO0: (MFJ MTF MMO-MUG PA COLL. SAMPLE POINT Ct NON CORTIRM CONFIRM NO. (Specific Address) RES~O pH COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER * ResuLts in :his coL~m are prestznptive. Total coliform and fecal coliform or E. coii confirmation uiLL foLLow in 24-48 hours. p - CoLiforms are present C - ConfLuent growth TA - Turbid, Absence of gas or acid A - CoLiform are absent TNTC - Too ncrnerous to count INVOICE AOORESS (if different than address betoa): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER ~MARKS: DAY TWO , NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: SATISFACTORY INCOMPLETE COLLECTION INFORMATION REPEAT SAMPLES REPLACEMENT SAMPLES State of FLorida Department of HeaLth Office of Laboratory Services Jacksonville, Miami, Per~acoLe Tampa, gent PaLm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS TESTED [CUNF I R~IEIJ :::" .'. '? i ' ? > . LAB USE ONLY Press hard, (5) copies -~: '_:- :~. ......... SYSTEM NAME: SYSTEM I.D. NO: ADDRESS: ~'--~.E~.','q,! -;"~Z~ ~ :".:~:;?~ ~"--.; - COUNTY: COLLECTOR: .... .:" :" '.... " SAMPLE SITE (Locality or Subdivision): SYSTEM PHONE #: COLLECTOR PHONE #: DATE AND TINE COLLECTED: TYPE OF SUPPLY(Circle one): Noncemmunity ~ater system Nontransient - noncona~nity ~ater system Pr~v~ ~in~ing pool Bottled ~ater~ited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement ~arance "gel[ survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Ra~ to county public health uni TO BE COMPLETED BY COLLECTOR OF SAMPLE T~E COMPLETED BY LAB ANALYSIS METHOD: /'-~'~"~ HTF HMO-MUG PA COLL. SAMPLE POINT Cl NON ~COR~IRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TO~L TOTAL FECAL E. COLI SAMPLE HUMBER ~1 ,'.~-:,~,>~_ ~. ~. ~ ~!,~ ~.'~z~ ....~ ~:~' ..... i ' -~. , - * Results in this column are presumptive. Total coliform and fecal coliform or E. coLi confirmation ~iLL fotLo~ in 2~-~8 hours. p - Coliform are present C - Confluent growth TA - Turbid, Absence of gas or acid A - CoLiforms are absent TNTC - Too numerous to count -- INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEgER xe_° HAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEgING OFFICIAL: TITLE: SATISFACTORY INCOMPLETE COLLECT[ON INFORMATION REPEAT SAMPLES REPLACEMENT SAMPLES State of Florida Depert~ent of Health Office of Laboratory Services decksonviLLe, Nimai, Pensacola Tm, West Pe[m Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS TESTED CON~ I H~ED SYSTEM NAME: ADDRESS: Press hard, (5) copies · .. _: -: '; i~.: ...,.:*: ';: ;, ~ ..:-. ': c"' ': ~; "~ i:-' '~: ._~ i ~ ~+ I/-'.. ~.~ ~-~ SYSTEM I.D.. NO: .. ~:'. -' :*?: ~' :. ~. ::' 7.. T':'?.Z .._~ ;",ia'~;'.:i~'--.~ !-_ COUNTY: L:oil!e~'~ SYSTEM PHONE #: DISTRICT: ii COLLECTOR: ~1'""'" ," ' L"~ COLLECTOR PHONE #: .~,~ ~:.~-:. SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: /-..~ ~'~.0 TYPE OF SUPPLY(Circle one):ccon~numTy~ater ~st_y_~llL_-NonconmJnity ~ater system Nontransient - nonconmunity aater system "l~t'i~[-l-"~-~uinming pool Battled uater Limited Use system SAMPLE(Circle one): Compliance Repeat Replacement ~ainclearanc~'/ Well survey Other TYPE OF (Check Box) [ ] Distribution ? [ ] Check hqre if payment made [ ] Ra~ to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO_BE COMPLETEO BY LAB ANALYSIS METNO0: t/'~lqF''', MTF MMO-MUG PA COLL. SAMPLE POINT Cl NON 'L'~R~IRM CONFIRM NO. (Specific Address) RES~O pH COLIFORM *TOTAL TOTAL FECAL E. COLZ SAMPLE NUMBER I * esutts in this col~am are pres~m~otive. Total coliform and fecal coliform or E. coil confirmation uill fotloe in 24-48 hours. p - Coliform are present C - Confluent growth TA - Turbid, Absence of gas or acid A - CoLiforms are absent TNTC - Too nLemrous to count INVOICE ADDRESS (if different than address below): '-'.:~ ~: ~-'..:: .L!*- * INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER eo NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: SATISFACTORY INCOMPLETE COLLECTION INFORMATION REPEAT SAMPLES REPLACEMENT SAMPLES MITCHELL & STARK CONSTRUCTION CO., INC. LICENSED GENERAL CONTRACTOR 6001 SHIRLEY STREET NAPLES, FLORIDA 34109-6202 PH: 941-597-2165 FAX: 941-566-7865 VERIFICATION OF FINAL COSTS CEDAR HAMMOCK- CLUBHOUSE DESCRIPTION SANITARY SEWER SYSTEM Sanitary Sewer Manhole 0-6 8" PVC Sanitary Sewer Main 0-6 Single Sewer Service Cu[ In Sewer Service w/3co's complete UNIT # UNIT TOTAL UP EA I $1,575.00 LF 23O $14.73 EA 2 $503.00 LS 1 $1,675.00 SUB-TOTAL TOTAL $1,575.00 $3,387.90 $1,006.00 $1,675.00 $7,643.90 WATER SYSTEM 8" PVC DR 18 Water Main and Fi[tings Fire Hydrant Assembly Single Water Service 4" Gate Valve Complete 3" Gate Valve Complete 2" BFP (no meter) Perm BlowOff 4" Fire Dectector System 4" P.I.V. & Siamese Connection 4" PVC DR 14 Fire Line 3" Sch 80 Water Main LF 238 $12.53 EA 1 $2,084.00 EA 2 $945.00 EA 1 $538.00 EA I $394.00 EA I $1,050.00 EA 2 $918.00 LS 1 $9,138.00 EA I $2,375.00 LF 270 $12.25 LF 320 $5.35 SUB-TOTAL TOTAL $2,982.14 $2,084.00 $1,890.00 $538.oo $394.00 $1,050.oo $1,836.OO $9,138.00 $2,375.00 $3,307.50 $1,712.00 $27,306.64 $34,950.54 AN EQUAL OPPORTUNITY EMPLOYER Professional Engineers, Planners & Land Surveyors January 24, 2000 Collier County Board of County Commissioners Collier County Government Complex 3301 East Tamiami Trail Naples, FL 34112 Reference: CEDAR HAMMOCK - CLUBHOUSE - SDP 99-152 CERTIFICATION OF UTILITIES WITHIN PLATTED R.O.W. OR DEDICATED EASEMENTS Ladies and Gentlemen: We do hereby certify that all water and sewer utilities to be dedicated to Collier County are located within the platted Right-of-Way or CUE's as shown on the attached plat of Cedar Hammock (Plat Book 32, gages 91 - 108), and within the proposed CUE being granted as part of the County acceptance of this project. Sincerely, BANKS ENGINEERING, INC. David R. Underhill, Jr., P.E. Florida Registered Engineer #47029 DRU/jmp S:~Reception\Letters~ 12xx\1263\County\Clubhouse\Clubhouse Utility Turnover\1263_ROWCcrt-Clubhouse wpd Lee County: 10501-104 Six Mile Cypress Parkway, Fort Myers, Florida 33912. (941)939-5490 · Fax (941)939-2523 Collier County: 2150-701 Goodlette Road, Naples, Florida 34102 · (941)403-8866. Fax (941)403-8868 WARRANTY/GUARANTEE THE UNDERSIGNED, Mitchell & Stark Construction Company, Inc. does hereby warrant and/or guarantee the Watermain, Sanitary Sewer and appurtenances installed at CEDAR HAMMOCK CLUBHOUSE, to be free from defects of materials and workmanship for a period of at least one year from the date of acceptance by the Owner and Engineer. THE UNDERSIGNED further agrees that it will, at its own expense, repair and replace all materials or installations which violate the covenants herein contained. DATE: 1-12-2000. Mitchell & Stark Construction Company, Inc. Michael J. I~qito, Project Manage DATE: January 12, 2000. State of Florida County of Collier Before me the undersigned notary public in and for the state and county aforesaid, personally appeared MICHAEL J. DEVITO, PROJECT MANAGER of MITCHELL & STARK CONSTRUCTION COMPANY, INC., a Florida Corporation, who acknowledged before me that they executed the foregoing document. Mo~(is Sons NOTXRY PUBLIC My commission · . .,?'~:,', ~:,;~,, Morris Sons exp]res.:~?. ~,, :,-- .t, (. ?,,': I,.'IYCOM,!~$$10N # CC67804~ · ,~ ,~ ~-',.'- ,' BONDED I~RU T;?OV FAIN INSURANCE. INC. Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans N~_m_ber __ i Date 176389 ~ 01/24/2000 9:42:31 AM Post Date ~ Pmt Slip # I Status 1__0!_(24_/2000'~ ~iiiiiiiiiii ~.~.6__~0_~ ~ POSTED MITCHELL AND STARK CEDAR HAMMOCK Payor · MITCHELL AND STARK Fee Information i Fee~Co__d_e__i Description i 42CYIN :COUNTY INVOICES 4080000001 Amount $472.77 Total $472.77 Waived Payments Payment Code i Account/Check Number Total Cash Total Non-Cash Total Paid Memo: DOR#599 FULL BORE FLUSH/BACT. TEST WO#11951/12131/19082 Amount: $472.77' $0.00 $472.77t $472.77] Cashier/location: GARRETT_S / 1 User: COLLAZO R Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:01/24/2000 9:42:58 AM JA~-:~I-O0 OS:Se FR0~ ADC NO. INVOICE BOARD OF COUNTY COMMISSIONERS COLLtEIP. COUN'~ COL~THOUSE COMPLEX NAPLES, FLORIDA 34112 T-148 P.0i/01 F-$95 Invoice; No. DOR599 Date: OCTOBER 18, 1999 TO: MITCHELL A ~ID STARK 602.7 SHIRL~ Y ST- NAPLES, FL 33942 Apptic PO No.: Department: Dept. of Revenue Phone: 403- ~365 -DUE AND PAYABLE UPON RECEIPT [BOARD DEPARTMENTS ONLY - CHARGES EXPENSED UPON RECEIPT OF YELLOW COPY IN FINANCE] CEDAR HAMM,: >CK FULL BORE F~i~/BAcT- TEST Work Order #119 H /12131/19082 Labor: 5.00 hrs- @ 15.00 per hour EquiPment 5hrs. @ 12.00 per hour Admins Cost materials lab anayls~s gallons water us, ;d79,852 TOTAL- AMOUNT 75.00 60.00 26.97 0 270.00 40.80 $ 472.77 408/253212/3~.! 330/00000 MA," E CHECKS pAyABLE TO COLLIER COUNTY BOARD OF COLJNTY COMMISSIONERS DETACH AND MAIL THI~ pORTION WITH YOUR CHECK TO COLLIER COUNTY REVENUE SERVICES 2802 N. HORSESHOE DRIVE NAPLES, FLOR1DA 34104 REVENUE ACCOUNT lnvo~:e: No. DOR599 FuND--~ COST CENT'I~ t OI~J/REV cOD~' I pROJE~CT[ 4~8 000000 115100 o0000 Ami E. IlCi: A/R No' 42CYIN EXPENDITU__~ F. ACCOUNT FUND t COST C~NTEII~ GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-6901 (941) 455-2121 · FAX (941) 455-7917 January20,2000 Collier County Board of County Commissioners Government Complex Center 3301 E. Tamiami Trail Naples, Florida 34112 Dear Collier County Commissioners: Subject: Cedar Hammock The Golden Gate Fire Control & Rescue District does not accept ownership nor does it maintain fire hydrants after their installation. Therefore, the Golden Gate Fire District will not assume ownership or maintain the fire hydrants located within the Cedar Hammock project. Sincerely, Donald R. Peterson Fire Chief DRP/pm ,~-, ~.~ ~.uoo zo~ o~ ~414557917 GOLDGATE FIRE ~=~TRT PAGE 02 GOLDEN GATE FIRE OONTROL & REVUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPt. F.~. FLORIDA 34116-6901 (941} 4~121 · FAX (941) 4,55-7917 .l'anuary 26, 2000 Tony Squiti~ Banks Ea~ineerin& Inc. 2150 Goodlette Road N. Naples, Florida :14102 Sub}_'ect: Hvdrnnt Flow Te~_. - C_~ I'tnmmoc~ On ~anuary 25, 2000, tbe Golden Gate l/re Control & Rescue D/str/ct did a flow test on one (1)fire hydrant/n the Cedar Hammock project. The remits are: Hydrant 03502614 - C~,-' N__n~mock Blvd. & Tennis Court- 7~ Stalic PSI 72 Residual PSI 60 Pitot Flow PSI 4426 GPM at 20 PSI Residual Before completion of the projeot, the hydrants need to be painted OSHA sa/cry yellow. The caps need to be painted OSHA safety light blue. Also, blue road rdleaors need to be installed to show location of all hydrants. This Fu~ District does not accept ownership nor does it maintain £,~= hydrants alter their installafio~ Total due the Golden Gate Fire Control District for thc flow test is S35.00. Siacerel~, Fire Chief DRP/pm Enclosure v~ ~.~ ~vv l~: ~ ~414557917 GOLI)GATE FIRE DEPTRT PAGE 03 HydrM~ Flow Telt~ Hydrant N~mb~ e4~J m "~14' 01/25/2000 14 ..... _C.._o_..W.,_.Sco~_[,~R/F~.._NG INE ER ,Subtotal Te~t~: 8tltlc Reeid Pltot 78 72 60 CEDAR HAMMOCK BLVD & TENNIS COURTS Pitm 2 GPM 0 1300 ~0 5194 Max: 1300 442~ 4623 5104 MIn: 1300 4426 4823 6194 Avg: 1300 4426 4823 6194 Tolzl Flow T#t~: I 01/25/2000 16:19 Page'. I Professional Engineers, Planners & Land Surveyors Sanuary 24, 2000 Collier County Board of County Commissioners Collier County Government Complex 3301 East Tamiami Trail Naples, FL 34112 Reference: CEDAR HAMMOCK- CLUBHOUSE - SDP 99-152 CERTIFICATION OF FIELD FIRE FLOW CAPACITY Ladies and Gentlemen: Based on the attached fire flow test we do hereby certify that the field fire flow capacity was examined and meets the design criteria for the previously submitted water system calculations for -the above referenced project. Sincerely, BANKS ENGINEERING, INC. David R. Underhill, Jr., P.E. Florida Registered Engineer g47029 DRU/jmp S:~=c¢~ioa~H2a~,12J~'~aumy~Clubhmm~.~2lubhou~ Uglity Tumov~1263._Fi~FIcrwC~t-~21al~om~wpd Lee County: 10501-104 Six Mile Cypress Parkway, Fort Myers, Florida 33912. (941)939-5490. Fax (941)939-2523 Collier County: 2150-701 Goodlette Road, Naples, Florida 34102 · (941)403-8866. Fax (941)403-8868 JAN-20--00 P.02 Customer Cedar IF~ :49 AM TANN;4SSEE FIRE PROTECT. 941 405 9~35~5 COLLIER ~,,,OUNTY CROSS CONNECTIOf* --,ONTROL Test And Maintenance Report Hammock SucctAddt'ess Cedar Hammock Blvd. Location of Assembly C1 ubhouse MaJlJng Address Typc Of Asscmbly RP [ ] Manufactt, rcr ~4 i 1 k i n s Test Guagc Manufacturcr .......... M i dwe s t Mctcr No. 990/40905 DC [~] PVB [ ] Fire Line ~ I Potable [ ] Model 950DA Serial No. D06352 Gauge Serial No. I t~l 7 5 7 Date Tested 1 / I B/O0 Size 1'1 CHECK VALVE #1 RELIEF VALVE CHECK VALVE #2 PRES. VACUUM BREAKER il i leaked opened at: _PSI [ ] leaked air inlet opened at laS] [x] closed tight [x] closed fight did not open [ ] gauge pre,sm e ' did not opcn [ ] gauge presaure check valve; across check across check leaked [ ] valve 14.2 PS! valve 1.5 . PSI held at.~ ........ PSI [ vi clcaned only [ ] cleaned only [ ] cleaned only [ ) cleaned only replaced: replaced: rcplaccd: replaced': CV assembly [ i RV assembly [ ] CV assembly [ ] ~..V assembly or or or disc, air in [ ] disc [ } disc [ ] disc [ 1 disc, C\r { 1 o-rings [ I dinphragrn(s) [] o-rings [ ] si)ring, air [ ] spring 11 spri,~g [] spring [] retainer J ] stem/guide [ ] gt, ide [] stcm/guide [ ] guide [ ] retainer [] o-rings [] retainer f] o-ring [ ] lock hms [ I other [ ] lock nuts [ ] other I ] or!mr Il other [] gauge lWC'.m'arc relief valve gauge pressure air inlet .... PSI across check o[)cncd at :<ross check Note: All ,'cp:fi~s shat! bc completed witlfin tcn (10) days. I%,narks. Pa_s.%ee ..... I kcrcbv ccrut\' lb:it this data i~ accuratc and reflects thc proper opcration and maintcnancc of the assembly. ...... - 'l'tstc~. Kenneth R. T, nnasse* Cert. No. H01053 Date t/18/00 Time COLLIER (;OUNTY CROSS CONNECTION ~;ONTROL 'rest And Maintenance Report Customer Cedar Hammock Street Address Cedar Hammock B1 vd. Mailing Address Location of Assembly C I ubhQu~O ..- Type Of Assembly RP [ ] DC Ix] PVB [ ] Fire Line [ ~ Model ~50xL __ ___ Gauge Serial No. Date Tested btanufacturer Wi i kl ns Test Guagc Manufacturer Midwest Meter No. Potable [ } Serial No. _9_p9368 141757 Sizc 3/4" ~/18/oo CHECK VALVE #1 RE. LIEF VALVE CHECK VALVE #2 PRES. VACUUM BREAKER [ ] leaked opened at: PS1 [ ] leaked air inlet opened at __PSI [~] closed fight [ ~] closed tight did not open [ ] gauge pressure did not open [ ] gauge pressure check valve: across check across check leaked [ ] valve 1.6 PSI vane 1.9 PSi held at .......... PSI [ ] cleaned only [ ]clcancd only [ ] cleaned only [ } cleaned only replaced: rep!aced: replaced: replaced: rubber ldt [ ] ruhl)cr kit [ ] rubl,cr kit [ ] rubbcr kit 1' ] CV assembly [ ] RV assembly [ ] {/iV assembly [ ] CV assembly ] ] or or or disc, air m { ] disc [ ] disc [ ] disc [ } disc, CV ] ] o-rings [] ,liaphrag, n(s) [1 o-dngs [1 spE.~g, :,ir ] ] scat l1 ,x.~t it .~c,~t 11 sp~:ipg, ¢:v J] spring J ] :;pring J ] .~pring [ ] rctmncr J ] stem/grade J ] guide J ] stem/~Hde [ ] gui.de j] retainer Il o-rings 11 retainer [] o-nng [I lock nuts J J ,)ti,er [ ] lock nuts [ ] other J ] mhcr l1 other ['l ~auge lWCSsm'e relief vane ga,ge pressure air inl,.:t ....... PSI :across check OlXmCd at ~:cross chec'< valve .... PSI ........ PSI valve __PSI chk. valve ............ PSI Nnte: All repairs shnll be completed within ten (I0) days. Remarks_ I hereby certify that this data is accurate and reflects thc proper operation and maintenance of the assembly. - .... Tester Kenneth R. Tannassee H01053 1/18/00 Ccrt, No ............. Date ............. 5:00 om 'I 'i in c ;Zn$inrerin$, i Professional Engineers, Planners & Land Surveyors January 24, 2000 Collier County Board of County Commissioners Collier County Government Complex 3301 East Tamiami Trail Naples, FL 34112 Reference: CEDAR HAMMOCK- CLUBHOUSE - SDP 99-152 INFILTRATION TEST CERTIFICATION Ladies and Gentlemen: We do hereby certify that the collection system was examined and that no infiltration into the collection system was noted for the above project. Sincerely, BANKS ENGINEERING, INC. David R. Underhill, Jr., P.E. Florida Registered Engineer #47029 DRU/jmp S \Reception\Letters~ 12xx\ 1263\County\Clubhouse\Clubhouse Utilil3' Turnover\ 1263_InfillrationCert-C1 ubhouse wpd Lee County: 10501-104 Six Mile Cypress Parkway, Fort Myers, Florida 33912. (941)939-5490 · Fax (941)939-2523 Collier County: 2150-701 Goodlette Road, Naples, Florida 34102 · (941)403-8866 · Fax (941)403-8868 ~ TSe Finest in Wasrewater Structure Rettabd~tarion. ~ C~-~O0, ~,m aecepeibte Idtumbous or el)oW 44~111aHo~.k liridl~t. I'lrk~vat. Nih I;f ..) CXI I £t_~ t~Jt~J b". ~LXZIt ~0~ I~X'ZX, ZTX_~- DATE OF REVIEW: 10-14-99 PROJECT NAME: Cedar Hammock, Phase 1, and Clubhouse, Multi-Family Tract F-5 (South) ENGINEER OF RECORD: CONSTRUCTION COld'tRacTOR: VIDEO CONTRACTOR: Sewer Viewer COMI(ENTS: Lines and services acceptable at this time but will review joint at 125 {t. in one year to make sure Joint does not leak [n line ~ S37 to ~ #33 RECOMMENDATIONS: xx__ I ACCEPTABLE: ~ R~VIEW NUMBERED COMMENTS IN ONE YEAR: Nm~ERED CO~S UNACCEPTABLE: OTHER RECOMMENDATIONS: COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 January 12. 2000 Mr. Tony Squitieri Banks Engineering, Inc 2150 Goodlette Rd., N. Suite 701 Naples, Florida 34102 RE: Cedar Hammock Clubhouse, Water & Sewer Dear Mr. Squitieri: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on January 12, 2000. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418. Sincerely, En~~e°ebles~'' ring Inspections Supervisor DN/taa/f:\Inspection form Cedar Hammock Clubhouse, water & sewer cc'. Cindy Erb, Engineering Technician, Public Works Joe Cheatham, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section 7Shirley Nix, Engineering Tech. II, Engineering Review Section File Phone (941) 403-2400 Fax (941) 6434968 www.co.collier, fl. us