Loading...
Silver Lakes, Phase 2-DMEMORANDUM DATE: March 5, 1999 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II ~'~-~ Project Plan Review RE: Silver Lakes, Phase 2-D Water and Sewer Facilities Acceptance Recording Fee Number 113-138312-649030 On J 6{~u~a[/~a~/~, 7E9~ The Board of County Commissioners granted ina acceptance of the water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded, in order: 1. Utilities Facilities Subordination, Consent and Joinder 2. Bill of Sale 3. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. o o 10. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Contribution-in-aid certification Certification of pressure testing of water lines by Engineer of Record Certification of pressure testing of sewer lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities Memorandum to Maureen Kenyon, Supervisor, Clerk to Board March 5, 1999 Page Two 11. DER Placement-in-Service letter for sewer facilities 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. Contractor's Final Release of Lien Lab results on bacteriological test for water lines Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing Certification of the inflow/infiltration test for the sewer lines by Engineer of Record Electrical Contractor's certification on Pump Station electric service wire sizing and voltage drop, pursuant to National Electrical Code specification Copy of pump station start-up report Copy of video tape test report Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations One copy of recorded plat One set of record drawings, signed and sealed by the Engineer of Record Memorandum to Maureen Kenyon, Supervisor, Clerk to Board March 5, 1999 Page Three If you have any questions, please call and advise accordingly. attachments doc:2094-2 0 t..) t,.) Lin. EC' 0'} ~ rn t.r~ L-d t-J .-~1 I'F1 "ri o 0 ,,¢] I'FI ' ITl ,0 ,:::i~-'. [ q - I:1 1"! J FF t 0o..t ~ m~zo O0 ~m 2445033 OR: 2521 PG: 1065 RBCORDBD in OFFICIAL RBCORDS of ¢OLLIBR COUNTY, FL o2/os/~so9 at 09:26AH DWIGHT B, I~RO~K, CLBRK RIC FBB 15.00 Retn: I#GIflIRIIIG RBVIIW SBRVICBS SHIRLBY MIX Form 4 - Rev. 4/28/89 (Utilities Facilities Consent and Joinder) Utilities Acceptance - Doc #320 UTILITIES FACILITIES SUBORDINATION, CONSENT AND JOINDER THIS SUBORDINATION, CONSENT AND JOINDER given this ~O'~ day of October, 1997, by Citizens Community Bank, (hereinafter referred to as "Mortgagee"), in favor of the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER- SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "County"). Mortgagee is used as singular or plural, as the context requires. W I TNE S SETH : WHEREAS, Mortgagee is the owner and holder of that certain Mortgage from Conquest Development USA, L.C., a Florida limited liability company, dated December 24, 1996, and recorded January 6, 1997, in O.R. Book 2268, Page 2159, of the Public Records of Collier County, Florida, (hereinafter referred to as "Mortgage"), encumbering the premises legally described therein, (hereinafter referred to as the "Encumbered Property"). WHEREAS, Mortgagee is the holder of that certain Assignment of Rents recorded January 6, 1997, in O.R. Book 2268, Page 2168, (herein referred to as "Assignment of Rents"), encumbering the premises legally described therein, (hereinafter referred to as the "Encumbered Property"). WHEREAS County has requested and received from the fee simple owner of the Encumbered Property non-exclusive easements for the installation and maintenance of utility facilities over and across a portion of the encumbered premises legally described in Exhibit "A" attached hereto and incorporated herein by virtue of this reference, which premises are hereinafter referred to as the "Easement Property". WHEREAS, County has requested that Mortgagee consent to, join in and subordinate its Mortgage and Assignment of Rents to the interest that County has in the Easement Property to which request Mortgagee has agreed. NOW THEREFORE, in consideration of TEN DOLLARS ($10.00) and other good and valuable consideration, the receipt of which is hereby acknowledged, the Mortgagee does hereby consent to, join in and subordinate the lien of its Mortgage and Assignment of Rents to the grant of that certain easement described herein over, under, and across the Easement Property and any interest of the County in any utility facilities located therein or affixed thereto. Except as subordinated to the easement described herein over, under, and across the Easement Property or any utility facilities located therein or affixed thereto, said Mortgage and Assignment of Rents shall remain otherwise in full force and effect. QBNAP\134494 . 1 OR: 2521 PG: 1066 IN WITNESS WHEREOF, the Mortgagee has caused these presents to be executed the date and year first above written. CITIZENS COMMI/NITY BANK PrinS Name: ~,Ji~ ~. ~/~,.~.. STATE OF FLORIDA COUNTY OF COLLIER The foregoing UTILITIES FACILITIES SUBORDINATION, CONSENT AND JOINDER was acknowledged before me by ~.~ ~ ~'~ , as ,~-~'~. ~'>*L Preside_~"of CITIZENS COMMUNITY BANK, on behalf of the Bank. He is (~/~) personally known to me or (__) has produced as identification and did take an oath. WITNESS my hand and official seal this day of " * 1997. My Commission Expires:6_~_~_d~_O0 QBNAP\134494 . 1 *** OR: 2521 PG: 1067 *** EXHIBIT A EASEMENT PROPERTY Ail sewer facilities located within Tract R of the plat of Silver Lakes Phase Two-D, according to the plat thereof as recorded in Plat Book ~q , Pages ~3z~ and 5~ , of the Public Records of Collier County, Florida. QBNAP\134494.1 Form 9 - Rev. 4/28/89 (Bill of Sale) Utilities Acceptance - Doc. #320 This Instrument Prepared by: Timothy G. Hains, Esquire QUARLES & BRADY 4501 North Tamiami Trail, #300 Naples, Florida 34103 2445034 OR: 2521 PG: 1068 {~¢ORI){D in OI~IClAI R~CO{ii)8 of COLLIER COUN'I'Y, FL metn: uc FHa 10.50 BNGINBBRING RBVIBff SBRVICBS SHIRLST NIX 5586 BILL OF SALE SILVER LAKES PHASE TWO-D SEWER UTILITIES THIS BILL OF SALE evidencing the sale and conveyance of the sewer utility facilities described herein is made this ,~dD day of October, 1997, by CONQUEST DEVELOPMENT U.S.A., L.C., a Florida Limited Liability Company, (hereinafter "Seller"), and the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District, its successors and assigns, (hereinafter "Buyer"). WITNES SETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: Ail sewer facilities located within Tract R of the plat of Silver Lakes Phase Two-D, according to the plat thereof as recorded in Plat Book ~q , Pages ~ and ~ , of the Public Records of Collier County, Florida. The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as sewer utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. IN WITNESS WHEREOF, SELLER has caused these presents to be executed the date and year first above written. Witnesses: /Prin~/ Name Print Name CONQUEST DEVELOPMENT L.C., a Florida Liability Company U.S.A. , Limited W Manager QBNAP\134491.1 *** OR: 2521 PG: 1069 *** STATE OF FLORIDA COUNTY OF COLLIER ~,~The foregoing instrument was acknowledged before me this day of October, 1997, by William E. Bridgett, as Manager of CONQUEST DEVELOPMENT U.S.A., L.C., a ~loxrida Limited Liability Company, on behalf of the Company. He (~') is personally known to me or (__) produced as identification, and he dw/~/did not take an oath. (SEAL) /Pri~nt/ame~ ~ Notary Public My Commission Expires: QBNAP\134491 . 1 October 29, 1997Fo~ 8 (Warranty ~ed) Utilities Acceptance - Doc. #320 Prepared by: Timothy G. Hains, Esquire QUARLES & BRADY 4501 North Tamiami Trail, #300 Naples, Florida 34103 Property ID# 00732640000 Underlying land *** 2445035 OR: 2521 PG: 1070 *** PJCORDRD in OFFICIAL RSCOND$ of COLLIItR COONTI, FL 03/09/1999 at 09:26AN DJ~IGHT g. BROCK, CLERK ~C FB! 6.00 DOC-, 70 .70 getn: SNIRL~T Nil il? 5586 SEWER UTILITIES FACILITIES SILVER LAKES PHASE TWO-D WARRANTY DEED THIS INDENTURE made this ~P day of O~.~., 1997, between CONQUEST DEVELOPMENT U.S.A., L.C., a Florida Limited Liability Company (hereinafter referred to as "Grantor"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). W I T N E S S E T H: That said Grantor, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: Ail sewer facilities located within Tract R of the plat of Silver Lakes Phase Two-D, according to the plat thereof as recorded in Plat Book ~ , Pages ~ and ~ , of the Public Records of Collier County, Florida, and said Grantor does hereby fully warrant the title to said utility facilities, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the land described above. Grantor and Grantee are used for singular or plural, as context requires. IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. P~int Name: ~/~/~ ~'~', ./~'/,~. STATE OF FLORIDA COUNTY OF COLLIER CONQUEST DEVELOPMENT U. S.A. , L. C., a Florida Limited Liability Company W illia~ E. B~/~/Manager The foregoin~ instrument was acknowledged before me this ~ day of ~Y~. , 1997, by William E. Bridgett, as Manager of CONQUEST DEVELOPMENT U.S.A., L.C., a Florida Limited Liability Company, on behalf of the Company. He is personally known to me and he did take an oath. (SEAL) MY COMMISSION # CC SO8215November 1999 EXPIRES: 6, Bonded Thru I~ I~bl~c Undem~dsrs /Name~ Notary Public My Commission Expires: QBNAP\ 134500.1 This Instrument Prepared by: Timothy G. Hains, Esquire Quarles & Brady 4501 North Tamiami Trail, Suite 300 Naples, Florida 34103 OWNER'S AFFIDAVIT SILVER LAKES - PHASE TWO-D SEWER UTILITIES ACCEPTANCE STATE OF FLORIDA COUNTY OF COLLIER ON THIS ~ day of October, 1996, before me personally appeared WILLIAM E. BRIDGETT, as Manager of CONQUEST DEVELOPMENT U.S.A., L.C., A Florida Limited Liability Company, owner of property to me personally known (hereinafter "Affiant"), who. being duly sworn on his oath, did say that all of the persons, firms, and corporation, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to the Owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant says that the subject real property is encumbered of record as follows: a) A Security Agreement executed by Conquest Development U.S.A., L.C., a Florida limited liability company, in favor of Citizens Community Bank, dated December 24, 1996, and recorded January 6, 1997, in Official Records Book 2268, Pages 2159 through 2167, inclusive, of the Public Records of Collier County, Florida. (b) Assignment of Rents, executed by Conquest Development U.S.A., L.C., a Florida limited liability company, in favor of Citizens Community Bank, dated December 20, 1996, and recorded January 6, 1997, in Official Records Book 2268, Page 2168, of the Public Records of Collier County, Florida. That certain real property referred to herein is also subject to the following: a) Easements, restrictions and other matters as described on the Plat of Silver Lakes Phase Two-D, as recorded in Plat Book '~ , Pages ~+ and 3~, of the Public Records of Collier County. b) That certain DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS FOR SILVER LAKES RV RESORT & GOLF CLUB, dated December 30, 1992, and recorded December 31, 1992, in Official Records Book 784, Pages 1103 through 1145, inclusive, and First Amendment to Declaration of Covenants, Conditions and Restrictions for Silver Lakes RV Resort & Golf Club, recorded June 9, 1993, in O.R. Book 1834, Pages 0248 through 0250; Second Amendment recorded December 16, 1994, in O.R. Book 2011, Page 2320; Third Amendment recorded December 28, 1994, in O.R. Book 2014, Page 1993; Fourth Amendment recorded October 4, 1995, in O.R. Book 2105, Page 1170; Fifth Amendment recorded October 24, 1996, in O.R. Book 2112, Page 0612; Sixth Amendment recorded March 7, 1997, in O.R. Book 2292, Page 0778; Seventh Amendment recorded March 7, 1997, in O.R. Book 2292, Page 0781; and as subsequently amended of record, inclusive, QBNAPl\107950 . all of the Public Records of Collier County, Florida. Affiant, as and on behalf of the Owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex- Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or material man, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described as: Tract R, SILVER LAKES PHASE TWO-D, according to the plat thereof recorded in Plat Book ~ , Pages ~4- and ~ , of the Public Records of Collier C-~nty, Fl~-~da. CONQUEST DEVELOPMENT U.S.A., L.C., a Florida Limited Liability Company By: ~ William E. ~id~3~tt, Manager The foregoing instrument was sworn to and subscribed before me this ~ day of October, 1997, by William E. Bridgett, as Manager of CONQUEST DEVELOPMENT U.S.A., L.C., a Florida Limited Liability Company, on behalf of the Company. He is personally known to me and he did take an oath. Notary Public (SEAL) My Commission Expires: Form 6 - Rev. 4/28/89 (Owners Affidavit) Utilities Acceptance - Doc. #320 QBNAP1 \ 107950. Form 5 - Rev. 4/28/89- (Attorney's Affidavit) Utilities Acceptance - Doc. #320 ATTORNEY'S AFFIDAVIT SILVER LAKES PHASE TWO-D SEWER UTILITIES ACCEPTANCE STATE OF FLORIDA COUNTY OF COLLIER ON THIS 27th day of October, 1998, before me personally appeared TIMOTHY G. HAINS, a licensed attorney authorized to practice in the State of Florida, (Florida Bar #173711) to me personally known, whose current business address and telephone number is 4501 North Tamiami Trail, Suite 300, Naples, Florida 34103, (941) 262-5959 (hereinafter "Affiant"), who, being duly sworn on his oath, does say: 1. The Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District to accept the dedication or conveyance of sewer utility facilities located within or upon the real property described in the attached Exhibit "A", which is incorporated herein by reference, said land being located in Collier County, Florida. 2. The Affiant has examined record title information to both the real property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 3. It is the opinion of the Affiant that, as of October 19, 1998, the record owner of the real and personal property described herein is CONQUEST DEVELOPMENT USA, L.C., a Florida limited liability company, (hereinafter "Owner"). The Owner acquired record title to the subject real property by instrument recorded in Official Records Book 1750, Page 1265, of the Public Records of Collier County, Florida, (previously provided). 4. The Affiant has examined the Articles of Organization and the Regulations of Conquest Development U.S.A., L.C. Conquest Development U.S.A., L.C. was validly formed and is currently in existence and active within the State of Florida. Conquest Development U.S.A., L.C. is currently authorized to do business within the State of Florida. The following are the names and title of persons authorized to execute instruments on behalf of Conquest Development U.S.A., L.C. in conjunction with the submission of the final subdivision plat to the Development Services Direction for approval by the Board of County Commissioners of Collier County, Florida: William E. Bridgett, U.S.A., L.C., and Manager, Conquest Development Wayne H. Henuset, Manager, Conquest Development U.S.A., L.C. Any one manager of Conquest Development U.S.A., L.C. shall have the right and power to bind Conquest Development U.S.A., L.C. 5. The subject real property is encumbered of record as fo].lows, copies of which were previously submitted: (a) A Security Agreement executed by Conquest Development U.S.A., L.C., a Florida limited liability company, in favor of Citizens Community Bank, dated December 24, 1996, and recorded January 6, 1997, in Official Records Book 2268, Pages 2159 through 2167, inclusive, of the Public Records of Collier County, Florida, (b) Assignment of Rents, executed by Conquest Development U.S.A., L.C., a Florida limited liability company, in favor of Citizens Community Bank, dated December 20, 1996, and recorded January 6, 1997, in Official Records Book 2268, Page 2168, of the Public Records of Collier County, Florida. 6. That certain real property referred to herein is subject to easements, restrictions and other matters as described on the Plat of Silver Lakes Phase Two-D, as recorded in Plat Book 29, Pages 34 and 35, of the Public Records of Collier County, Florida. 7. That certain DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS FOR SILVER LAKES RV RESORT & GOLF CLUB, dated December 30, 1992, and recorded December 31, 1992, in Official Records Book 784, Pages 1103 through 1145, inclusive, and First Amendment to Declaration of Covenants, Conditions and Restrictions for Silver Lakes RV Resort & Golf Club, recorded June 9, 1993, in O.R. Book 1834, Pages 0248 through 0250; Second Amendment recorded December 16, 1994, in O.R. Book 2011, Page 2320; Third Amendment recorded December 28, 1994, in O.R. Book 2014, Page 1993; Fourth Amendment recorded October 4, 1995, in O.R. Book 2105, Page 1170; Fifth Amendment recorded October 24, 1996, in O.R. Book 2112, Page 0612; Sixth Amendment recorded March 7, 1997, in O.R. Book 2292, Page 0778; Seventh Amendment recorded March 7, 1997, in O.R. Book 2292, Page 0781; and as subsequently amended of record, inclusive, all of the Public Records of Collier County, Florida. 8. Affiant further states that the information contained in this Affidavit is, to the best of his khowledge, true, correct and current as of the date this Affidavit of Title is given, except as otherwise provided herein. STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was sworn to and subscribed before me this 47 day of October, 1998, by Timothy G. Hains who is personall'y known to me and who did take an oath. .... //Name:JSUZANNE HOWARD Notary Public (SEAL) My Commission Expires: Exhibit A SILVER LAKES PHASE 2-D LEGAL DESCRIPTION A PORT/ON OF THE SOUTH ONE-HALF OF THE SOUTH ONE-HALF OF SECTION I0 AND A PORTION OF SECTION 15, TOWNSHIP 51 SOUTH, RANGE 26 EAST, COLLIER COUNTY, FLORIDA, MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGIN AT THE SOUTHEAST CORNER OF LOT 54, BLOCK 3, SILYER LAKES, PHASE TWO-B, AS RECORDED IN PLA T BOOK 25, PAGES 69 THROUGH 70, OF THE PUBLIC RECORDS OF COLLIER COUNI'X, FLOR/DA, AND RUN NOO'46'52"E FOR 90.00 FEET TO THE SOUTHERLY RIGHT-OF-WAY LINE OF SILVER LAKES BOULEVARD; TWO-B, AS RECORDED IN PLA T BOOK 25, PAGES 69 THROUGH 70, OF THE PUBLIC THENCE RUN NOB'52'44"E FOR 68.07 FEET TO THE NORTHERLY RIGHT-OF-WAY LINE OF SILVER LAKES 80ULEVARD ; THENCE RUN N4¢52'40"E FOR 262.5,; FEET; THENCE RUN NgO'OO'OO"E FOR 522.09 FEET,' THENCE RUN S61'26'54 FOR 826.18,,EFEET,, THENCE RUN S4,,T42'O3"E FOR 97.90 FEET; THENCE RUN S88'03'29 FOR 72.77 FEET; THENCE RUN S00'39'23"W FOR 67.61 FEET; THENCE RUN NB,q'20'37"W FOR 11.04 FEET; THENCE RUN 500'39'23"W FOR 200.14 FEET; THENCE RUN N89'20'JT"W FOR 1137.99 FEET; THENCE RUN NOC 39'23"E FOR 110.00 FEET,. THENCE RUN N89'20'37"W FOR 974.92 FEET TO A POINT OF CURVATURE OF A CURVE CONCAVE NORTHWESTERLY,, THENCE RUN 287.98 ANGLE OF 54'59'58", A CHORD OF 277.05 FEET AND A CHORD BEARING OF FEET ALONG THE AR.CE OF SAID CURVE HAVING A RADIUS OF 500.00 FEET, AN INCLUDED N6.TlO'5t ro A POINT OF TANGENCY,, THENCE RUN N35' 40'52"E FOR 156. J4 THENCE RUN 57 70 FEET ALONG SAID CURVE HAVING A RADIUS OF 60.00 FEET, FEET TO A POINT OF CURVATURE OF A CURVE CONCAVE SOUTHEASTERLY,, AN INCLUDED ANGLE OF 55'06'00", A CHORD OF 55,50 FEET AND A CHORD BEARINO OF N63'13'52"E TO A POINT OF TANGENCY,. THENCE RUN S8~715'08"E FOR 1.37,03 FEET TO THE POINT OF BEGINNING, CONTAINING 22, 14 ACRES, MORE OR LESS, This instrument prepared bv~nf -~,,~ DAVID C. BOURGEAU -~LIER COUNTY p s, Florida 33940 Property Appraiser's Parcel Identification Number: 0074200009 and 0072840000 Grantee(s) S.S. RECORDED THIS INSTRUMENT WAS PREPARED WITHOUT THE BENEFIT OF LEGAL OPINION OR TITLE EXAMINATION WARRANTY DEED CD THIS WARRANTY DEED made thi~ 20th day o~ 'AuRust 1992, by GEORGE T. DOWNEY and SANDRA G. DOWNEY] husband and wife, hereinafter called the Grantors,! to CONQUEST DEVELO~MENT U.S.A., CD ( L.C., a Florida Limited Liability ComDany, whos~..post office ~ ¢ address is Post Office Box 758, Marco Island, FIorida. 33969 ' hereinafter called the Grantee: ' WITNESSETH: That the Grantors, for and'in consid~ation of the sum of $'10.00 and other valuable considerations, r~c6ipt whereof is hereby acknowledged, hereby grant, bargain, sell, ~n, remise, release, convey and confirm unto the Grantee all that~:'certain land situate in Collier County, State.of Florida, viz: See Exhibit "A"'a~tached hereto and incorporated herein. SUBJECT to zoning, building code and other:.~estrictions GD ~o imposed by governmental authbrity, reserva~Lion of oil, ~ cD gas and mineral interests, restrictions ah~ -asements of. cn record, and ad valorem real property tax-s accruing subsequent to December..31, 1991. SUBJECT ALSO to the following mortgagm~ which the Grantee hereby assumes and agrees to pay:. 1. Mortgage from R.~ Elliot Aronheim, a~d. Doran. L. Bouchard to Dr. A.. E. Rhoden, dated August 8, 1988, and recorded August 17, '1988 in O.R. BOOk 1373, Page 971, Public Records of Collier County~ Florida. 2. Mortgage from George T. Downey and SaR~ra G. Downey to William E. Bridgett, Sandra L. Bridgeltt and Wayne F. Henuset, dated~ December 8, 1988, ~nd recorded December 14, 19881, in O.R. Book l~OO, Page 118, Public Records ofiCollier County, F!0~da. TOGETHER, with all tenements~ hereditaments and appurtenances thereto belonging or in anywise, a?pertaining. '" TO HAVE AND TO HOLD the same in fee simple fOra.ye~ EXHIBIT "B" AND the Grantors hereby covenant with s~id G~antee that the Grantors are lawfully seized of said land in ~ee s~Die; that the Grantors have good right and lawful authority to ~il and convey said land, and hereby warrant ~the title to said~and and will defend the same against the lawful claims of':.'all persons whomsoever; and that said land is free of all encumbrances, except taxes accruing subsequent to December 31, 1991~ ..~'.. IN WITNESS WHEREOF, the said Grantors have si~n~d and sealed :these presents the day and year'first above SS ~1 Signature ~ 'Si~nat~e Susan T. Roy Witness #1 Printed Name bna. Ku~l~r Witness ~rinted Name ~it~ess #1 Signature f - Susan T. Roy //' John R~; Kugler 7 / Witness 2~~{~ed Name - GEORGE T. DOWNE~i: ' Printed Name ::'.'. · Wells, ME 04090 ~ost Office Addr~,SS ~tgnature ' ' SANDRA G. Printed Name P.O. Box 367' _ Wells, = Pos't Office Addr'~ss STATE OF MAINE COUNTY OF YORK The foregoing instrument was acknowledged befog6 me this2J~Lh day of August ,1992, by George T. Downey and sand~a G. Downey, who are personally known to me or.who have produced'~rtver,s license as identification and did take an?oath. Notary Public signature~ - Susan T. Roy ,.. Notary Public Prt~.ted Name State of _MAINE ": at Large My commission expk~.es: OR BOOK PAOE EXHIBIT "A" The property conveyed included both Parcel I and Parcel II. PARCEL I The North 220.0 feet of the North 1/2 of the North 1/2 of Section 15, Township 51 South, Range 26 East, lying east of State Road 951, Collier County, Florida, and The South 1/2 of the'South 1/2 of the Southwest 1/4 of Section 10, Township 51 South, Range 26 East, lying east of State Road 951, and the South 1/2 of the Southwest 1/4 of the Southeast 1/4 of Section 10, Township 51 South, Range 26 East, and the Southeast 1/4 of the Southeast 1/4 of Section 10, Township 51 South, Range 26 East, all in Collier County, Florida;. LESS AND EXCEPT that property described in that Deed recorded at O.R. Book 1272, Page 1189, Public Records of Collier County, Florida, conveying a parcel approximately 35 acres for the realighnment of SR 951. ' PARCEL II That portion of the North-half (N1/2) of the South-half (S1/2) of' the Southwest Quarter (SW1/4) lying east of State Road S-951, and the North-half (N1/2) of the Southwest Quarter (SWl/4) of the Southeast Quarter (SE1/4) of Section !0, Township 51 South, Range 2r6 East, Collier County, Florida; Less all that part of the North-half (N1/2) of the South-half (S1/2) of the Southwest Quarter (SW1/4) of Section 10,. Township 51 South, Range 26 East, lying east of State Road S-951, lying 100 feet left and 100 feet right of the following des¢~ibed centerline: From the Southwest corner of Section 15, Township 51'South, Range 26 East, Collier County, Florida, run S 88' 58~ 22" E along the South line of the southwest Quarter (SW 1/4) of said Section 1138.93 =- .... fe~t .to the centerline of constructi ........ 15_for - , . , gu~uzon z~4 + 04.46 and ~he Point of ueg~nn~ng. From said Point of Beginning run N 02 28' 03" parallel with and 33 feet Westerly from the centerline of Sta~e Road S-951 (100 feet wide) for 15,452.33 feet t ~6.79 at the centerline of U.S ~ ...... ? Station 448 + uescribed centerline. · ~ ~nu une end of the herein Bearings are Plane Coordinate for the Florid~ East Zone. COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION 2800 NORTH HORSESHOE DRIVE NAPLES. FL 34104 ENGINEERING REVIEW SECTION December 3, 1998 Ms. Gina Green, P.E. McAnly Engineering 5101 Tamiami Trail East, Suite 202 Naples, FL. 34113 Re: Silver Lakes Phase 2-D Dear Gina: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. Ail water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very, truly yours, John R. Houldsworth Senior Engineer Building Review & Permitting Code Enfomement Housing & Urban Improvement (941 ) 403-2400 (94 i ) 403-2440 (94 !) 403-2330 Natural Resources Planning Services Pollution Control (941) 732-2505 (941) 403-2300 (941) 732-2502 COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION December 3, 1998 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 Gina Green MeAnly Engineering 5101 Tamiami Trail E. #202 Naples, FL 34113 Re: Silver Lakes, Phase 2-D Dear Gina: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, ShirleyNix Engineering Technician II cc: Tim Clemons, Wastewater Director Cindy Erb, Public Works lnhn Mcmld~wc~rth Engineering R~Yi~W Building Review & Permitting (941 )403-2400 Code Enforcement (941) 403-2440 Housing & Urban Improvement (94 i)403-2330 Natural Resources Planning Services Pollution Control (941) 732-2505 (941 ) 403-2300 (941 ) 732-2502 CERTIFICATION CONCERNING CONTRIBUTION-IN-AID OF CONSTRUCTION The undersigned, on behalf of CONQUEST DEVELOPMENT, U.S.A., L.C., a Florida Limited Liability Company, developer of SILVER LAKES, PHASE TWO-D, certifies as follows: The developer has received no contribution-in-aid of construction or development from sources other than the developer or its mortgagee, relative to the sewer facilities within the property described on the attached Exhibit "A". CONQUEST DEVELOPMENT, U.S.A., L.C. a Florida Limited Liability Company by its Manager, William E. Bridgett By: ~f Conquest Development, U.S.A., L.C. :ANL.'Y-ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPE ARCHITECTURE HYDROSTATIC TESTING Projcct: ~ilvor T~lco.~ Ph;a~ TT--rl Projcct Number: 88776.2 Date of Test: 7/28/97 Those Present: Randy Casey, Todd Procell, Description o£ Linc Tested: T~t Pressure: Collier County ~Anly ~ngln.c~.r!ng and Florida State Underqround 1872 LF of 8" Water Main 153 psi ID_C _ CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: (Length of Pipe) x (Diameter of pipe) x SQR(Tcstprcssure) / 133200 ( 1827 fi) x ( 8 m) x SQR( 153 psi) / 133200 = ( fl) x ( in) x SQR( psi) / 133200 = ( fl) x ( in) x SQR( psi) / 133200 = ( fl) x ( in) x SQR( psi) / 133200 = Total RESULTS OF TEST: Length of Test 2 Hrs. Pressure at Beginning of lest: Pressure at End of test: 1.39 gal gal gal gal 1.39 gal 153 psi 152 psi Allowable Leakage 2.78 gal psi psi Amount of water required tO bring pressure up to beginning pressure: Enginccr: MeAnly Engineering and Design, Inc. 0 gal 5101 TAMIAMI TRAIL EAST, SUITE 202, NAPLES. FLORIDA 34113 (941 ) '¢75-O723 FAX (941 ) 77?9236 cANLY-ENGIN EERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPEARCHITECTURE HYDROSTATIC TESTING Project: $11v~r T,.-nk'o.~ PhR.qo TT-D Project Number: 88776.2 Date of Test: Those Present: 7/28/97 Randy Casey, Sh~n~ Park~r~ Todd Procell, Test Pressure: Collier County H~Anly Rng~n~e_r!ng and De_si=~p_; Florida State Underground 100 psi Description of Line Tested: 2555' of 4" Force Main CALCULATION OF ALLOWABLE LEAKAGE PER ONE HOUR: (Length of Pipe) ( 2555 ( ( ( x (Diamctcrofpipc) x SQR(Tcstprcssure) / 133200 fi) x ( 4 in) x SQR( 100 psi) / 133200 = fi) x ( in) x SQR( psi) / 133200 = ft) x ( in) x SQR( psi) / 133200 = ft) x ( in) x SQR( psi) / 133200 = Total RESULTS OF TEST: Length of Test 2 Hrs. Pressure at Beginning of test: Pressure at End of test: Amount of water required to bring pressure up to beginning pressure: Engineer: MeAnly Engineering and Design, Inc. 0.77 gal gal gal gal O. 77 gal Allowable Leakage 100 1.53 100 0 gal psi psi gal 5101 TAMIAMI TRAIL EAST, SUITE 202, NAPLES, FLORIDA 34113 _~.(941 ) 775-0723 FAX (941 ) 775~9236 ~ 11-17-1998 12:15AM FROM MEANLY ENGINEERING & DESI TO 6436968 P.02 Lawton Chlles Governor Department of Environmental Protection William E: Brtd ~ Manager Conquest Deve~ ~pment U.S.~, L.C. ~3s~ Q~ata~ Court Marco Island, l~lorkla 3414~ South District P.O. Box 2549 Fort Myers. Florida 33902.2549 Virginia B. We~herell Secretary Novembet13,1998 Re: ~llier County - PW Silver Lakes RV & Golf Resort Final Clearance - Phase Two-D (Collier Coumy Reglo~al WTP) DSI 1-234489 Dear Mt. Btid ~tt: i ......... a:~*-4~,..tion ~stem extension has been completed in accolx~nce Mm m~ DS! 1-234489 Idaled Au~t 6, 1993. i - ........ ' .... arc a~'~rov~,e these facilities for service · 'on and satiM'ac~ry bactenmo~cm Based on this ,~rfifioati ........... . ..... colloated nrior to replacement of the " ' *tlOtlS' under the.foll~ng condi ' ' - ........ t-:th a final connection, then addlttonal ' F temnoratv bac~low preventer o pora.ry ............ :,~ collect a bacteriological sample ~- - - - ' · · . lotion ot ~ imm f~muw~uuu, . t,~cteriolo~ic~l samp-ling m teqmred. Upon comp ........ , ------ ,,- th~ r~attment Immediate ~' . ~---~- ..... ,- .... -~;,-,- --d bruit the eactenoto~u ~u,~ ,~, ~-r · immediately qownst~eam or z~ ~u, ......... su service can I~ provided ifa precautionary boil water notice is issaed for areas down stream of thc connection, until one day bf satisfactory bacteriolol~cai ve, sulls have been obtained (Two consecutive days of satisfactory bactefiologica, lI results are required following any unsafisfactmT result). · project will t~pfire a new permit from ~e Depa~tm . Your continued cooperation in our water supply program is a~' preciated. ' Oi~~a R. Green, P.E. PaUl E. Mattausch Sincerely, Oa~ A, Maier Professionnl Engineer "Protect, Conserve crud/vlono£e RorJdo's Environment ~nd Noturol Resources" R, inted on reeyded paper. TOTAL P.02 11-21-1998 02:05AM FROM MEANLY ENGINEERING & DESI TO 6436968 Environmental Protection South D~'t P.O. Box 2~4g Nov~r 20, 1998 Coille~ County Utilities 3301 F~t Tamiam! Trail Naples,! Florida 34112 Dear Mr. Clemon=: Collie~ CountY'-- DWICS partial oleazan~e £oz Usa DEP Permit No. cs11-234496 silver La,es RV and Golf ~esort, Phase Two-D' Co~eot~ to~ Sou~ Collier Coun~ ~g~onal~ 5ou~we~ Coast ~ Wa haw received a partial certificate of completion of constriction on November 10, 1998, as submitted Engin~=ing and Design, Inc., for Phase 2-D of :he au~hor~.z~dbyTJme above permit number. Aocora~ngly, domasti.c' wastewater collection/transmission ~ystemmay be placed:into service. sinoerely, ~ ~ohn A. ~.rong, P.Z. Section Supervisor Domestic Wa&ts Permitting Wa=er Facilities JAA/rW cc' Gins Gree~, P.E., MCAnI¥ ~.ngin.~ering and Design, Inc. 1-21-1998 81: 49AM P. 02 TOTAL P. 02 FINAL RELEASE OF LIEN KNOW ALL MEN BY THESE PRESENTS: That the undersigned, for and in consideration of the payment of the sum of TEN DOLLARS (10.00) paid by CONQUEST DEVELOPMENT,LTD/CONQUEST DEVELOPMENT U.S.A., receipt of which is hereby acknowledged, hereby releases and quit claims to the said SILVER LAKES its successors and assigns, and the owner, all liens, lien rights, claims or demands of any kind whatsoever, which the undersigned now has or might have against the building on premises legally described as SILVER LAKES PHASE lid SECTION 10 & 15, TOWNSHIP 51 S, RANGE 26E COLLIER COUNTY, FLORIDA on account of labor performed and/or material furnished for the construction of any improvements thereon. That all labor and materials used by the undersigned in the erection of said improvements have been fully paid. IN }FITNESS WHEREOF, I have hereunto set my hand seal this 27th day of October, 1997 WITNESSES: STATE OF FLORIDA COUNTY OF COLLIER FLORIDA STAT ~U/NDI~RGROUND, INC. The foregoing instrument was acknowledged before me this 27th day of October, 1997 by Thomas P. McKimm, on behalf of the company who is personally known to me and did not take al~ath d,~4'.~,~ d,-'3'~---.zS(.~,~./,,.~ My Commission Expires: NOT~Y ' Notary PuDIic - State of Flark~ W My Commission Ex,res ~ ~9, ~1 ~ C~mlss[on ~ CC67~3 CULLIGAN OPERATING SERVICES, INC. 1998 Trade Center Way Naples, Florida 34109 (941) 597-6059 (941) 936-6609 (941) 639-5325 FAX (941) 597-7056 DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY LAB CERTIFICATION #85197 SYSTEM NAME. ADDRESS: COL LECTOR: .S/7///¢ //,/¢ ///' SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: /,2/~,/~' SYSTEM,.D. NO:SYSTEM P,O,E,: COUNTY: ~/~ ~ DER DISTRICT: COLLECTOR PHONE ~: TYPE OF SUPPLY (Circle one): o~"'6"~"~mmunit7 w. ater .~y~tem~ Non community water system Nontransient - non community water system Private well Swimming pool Bottled water Other public water system TYPE OF SAMPLE (Circle One): Repeat Replacement ~~:) Well survey Other Compliance (Check Box) (Check Box) [] Distribution i-ITNTC or C [] Raw i-lTurbid (Specify) REMARKS: TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY~-~,~ ANALYSIS METHOD: MF MTF PA COLL. SAMPLE POINT CL NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH SAMPLE NUMBER COLIFORM *TOTAL TOTAL FECAL * Results in this column are preliminary. Fecal coliform confirmation on community and noncommunity water systems and total coliform confirmation on all types of water systems will follow in 24 - 48 hours. P - Coliforms are present A - Coliforms are absent C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INTERPRETATIONS- REMARKS BY PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: ( ) ) SATISFACTORY ) INCOMPLETE COLLECTION INFORMATION ) REPEAT SAMPLES ) REPLACEMENT SAMPLES TITLE: CULLIGAN OPERATING SERVICES, INC. 1998 Trade Center Way Naples, Florida 34109 (941) 597-6059 (941) 936-6609 (941) 639-5325 FAX (941) 597-7056 DRINKING WATER BACTERIOLOGICAL ANALYSIS ADDRESS: COLLECTOR: //~At/<~,/'~/ ~ [~ SAMPLE SITE (Locali~ or Su~ivision):. FOR LAB USE ONLY RECEIVED: ? ANALYZED:/~//~/?2 ~ ~','/-4 ,~' ~ .,, PHC, E,: COLLECTOR PHONE #: ~PE OF SUPPLY (Circle one~W wat~ Non communi~ water system Nontransient - non communi~ water system - Private well Swimming p~l ~EI~ water O~er public water system ~PE OF SAMPLE (Circle One): Complian~ Re.at Replacement ~n clearan~ ; Well su~ey O~er (Ch~k ~x) (Ch~k ~x) ~ ~ Distribution ~TNTC or C ~ Raw ~Turbid REMARKS: (Specify) TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB ~ ANALYSIS METHOD: ME IvrrF~(' MMo-MuG~ PA COLL. SAMPLE POINT CL NON~' ~ CONFIRM NO. (Specific Address) RES'D pH SAMPLE NUMBER COLIFORM *TOTAL TOTAL FECAL * Results in this column are preliminary. Fecal coliform confirmation on community and noncommunity water systems and total coliform confirmation on all types of water systems will follow in 24 - 48 hours. P - Coliforms are present A - Coliforms are absent C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INTERPRETATIONS- REMARKS BY PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: ( ) ) SATISFACTORY ) INCOMPLETE COCLECTION INFORMATION ) REPEAT SAMPLES ) REPLACEMENT SAMPLES TITLE: FLORIDA STATE UNDERGROUND, INC. CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: SILVER LAKES PHASE liD THIS IS A: WATER SYSTEM DATE: OCTOBER 21, 1997 SEWER SYSTEM XX ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST PVC 0-6 8" 885 LF 14.09 12,469.65 PVC 6-8 8" 542 LF 16.09 8,720.78 PVC 8-10 8" 619 LF 22.84 14,137.96 PVC 10-12 8" 499 LF 27.59 13,767.41 PVC 12-14 8" 324 LF 32.84 10,640.16 PVC 14-16 8" 14 LF 34.84 487.76 MANHOLE 0-6 3 EA 1,086.70 3,260.10 MANHOLE 6-8 2 EA 1,212.40 2,424.80 MANHOLE 8-10 2 EA 1,544.10 3,088.20 MANHOLE 10-12 1 EA 2,093.90 2,093.90 MANHOLE 12-14 2 EA 2,420.40 4,840.80 LIFT STATION #3 1 EA 42,136.00 42,136.00 LATERALS 6" 95 EA 310.63 29,509.85 DR 18 FORCEMAIN 4" 2640 LF 6.51 17,186.40 SEWER TV 1 LS 2,850.00 2,850.00 TOTAL 167,613.77 I DO HEREBY CERTIFY THE ABOFE DESCRIBED LIST OFMATERIALS, QUAhTITIES OF MATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE AS PER FINAL PAY ESTLglATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROdECT AND/OR DESIGN ENGINEERS CflRTIFIED RECORD PERSONALLY KNOWN, SWORN TO ., CERTIFYING: .- / _ & SUBSCRIBED BEFORE ME THIS .., '~.~AY F.Q~5 7Z :4gr, Z~ ,1997 T~.~eI~,, PRESDENT /~,,'~..~ _.,~f_~ ~//_ ~.~ .... ~ ,, FLORIDA ST/V'~"UNDEROROUND, INC. (NOTAI~ PUBLI~~,~I~JgE~ S C ~-AEV [ R r ~1~ NO'Ct,, =,.~ :C - S'~:'e c~ F;oddo ~ My C::' :' ~$"eS ~.-:r: 9 200! FLORIDA STATE UNDERGROUND, INC. CONTRACTOR'S CERTIFIEI) LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: SILVER LAKES PHASE liD THIS IS A: WATER SYSTEM XX DATE: OCTOBER 21, 1997 SEWER SYSTEM ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST DR 18 8" 1529 LF 10.55 16,130.95 DR 14 8" 60 LF 12.26 735.60 DR 18 6" 194 LF 8.74 1,695.56 GATE VALVE 8" 3 EA 599.11 1,797.33 GATE VALVE 6" 1 EA 450.71 450.71 FIRE HYDRANT 4 EA 1,680.78 6,723.12 AIR RELEASE 1 EA 1,501.30 1,501.30 TEMP. BLOW OFF 1 EA 699.11 699.11 CONNECT TO EXISTING 1 EA 379.50 379.50 DBL WATER SERV. SHORT 18 EA 322.61 5,806.98 DBL WATER SERV. LONG 23 EA 450.76 10,367.48 SNG WATER SERV. SHORT 2 EA 178.99 357.98 SNG WATER SERV. LONG 1 EA 247.65 247.65 TOTAL 46,893.27 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OFMATERIALS, QUANTITIES OFMATERIALS, KINDS OF MATERIALS, INCLUDING L¥STALLA TION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CO~rI'RACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGINEERS CERTIFIED RECORD DRAWINGS OF THIS SYSTEMAS DESCRIBED BY NA3JE SHOWN, AS OF THIS DATE/ PERSONALLY KNOWN, SWORN TO CERTIFYING::/ & SUBSCRIBED BEFORE ME THIS -~--~_-~--~:~ ...... "~ ~~A Y OE~//7,~¢7~__. ,1997 '/THOMAS~~,~PREsIDENT ~ ,/~/ FLOR:IDA STATE UNDERGROUND, INC. (NOTAR~ PUBLIC NAME & SEAL) c.~oF~c xwPwnmwP ] }~I~T ~ - Stoto Of FIO~::Ia · McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPEARCHITECTURE November 10, 1997 Mr. Thomas E. Kuck, P.E. Project Plan Review Manager 2800 North Horseshoe Drive Naples, Florida 34112 Collier County Wastewater Treatment Plant - South Area Silver Lakes, RV and Golf Resort, Phase Two-D Dear Mr. Kuck: The purpose of this letter is to certify that all sewer facilities for the above referenced project are located within the Private Right-of-Way or utility easements which are dedicated Collier County Utility Easements. All improvements are constructed in accordance with the approved construction plans and specifications. Sincerely, Gina R. Green, P.E. GRG/lkm c: file lkm\c :\winwordX.silverb.\cet'~o~.doc 5101 TAMIAMI TRAIL EAST, SUITE 202, NAPLES, FLORIDA 34113 (941) 775-0723 FAX (941) 775-9236 October 27, 1997 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 33964 WATER DISTRIBUTION SYSTEM SILVER LAKES PHASE liD SECTION 10 & 15, TOWNSHIP 51 S, RANGE 26E COLLIER COUNTY NAPLES, FLORIDA Gentlemen: This letter is to certify the completion of the WATER DISTRIBUTION SYSTEM located within SILVER LAKES PHASE IID. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier County Board of Commissioners. Sincerely, President TPM/cvk C :\office\wlmin\wpdocs~ccwarr 73 COMMERCIAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449" FAX: 643-6891 ~'lorlda State Undergrounc October 27, 1997 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 33964 SEWER DISTRIBUTION SYSTEM SILVER LAKES PHASE liD SECTION 10 & 15, TOWNSHIP 51S, RANGE 26E COLLIER COUNTY NAPLES, FLORIDA Gentlemen: This letter is to certify the completion of the SEYV ER I)ISTR! Blil'ION SYSI'I!;M located within SILVER LAKES PHASE IID. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier County Board of Commissioners. Sincerely, ./ President TPM/cvk C:\oflice\wpwtn\wpdocs\ccwarr 73 COMMERCIAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891 OFFICE OF THE FIRE MARSHAL East Naples Fire Control and Rescue District DATE: 12/15/97 TO: UTILITIES DIVISION, SITE PLAN REVIEW FROM: EAST NAPLES FIRE DEPARTMENT REF: FIRE HYDRANT OWNERSHIP AND MAINTENANCE GENTLEMEN: The East Naples Fire Control and Rescue District agrees to accept ownership and maintenance of the hydrant(s) located at: Silver Lakes ( 4 hydrants ) This ownership and maintenance agreement shall not in any way be construed to alleviate the owners, developers, contractors etc.., from any liabilitiy for damages that may occur subsequent to this agreement as a result of faulty equipment, installation and/or damage by construction vehicles. Further, the water su0.oly to this/these hydrants shall not be disconnected at any time hereafter without notifying the East Naples Fire DePartment. Sincerely, Gayland Moore FIRE MARSHAL, ENFD 4798 Davis Boulevard / Naples, FL FAX (813) 774-1782 33942 / (813) 774-7111 / 11-06-1998 11:06PM FROM MEANLY ENGINEERING ~ DESI TO 6436968 P.03 OFFICE OF THE FIRE MARSHAL East Naples Fire Control and Rescue District FIRt HYDRANT FLOW TEST INVOICE Date Tested:! 1 2/1 6/97 Time;,2:0~l T~ted I~y: qm Reauested Bv:i Ted Bridqett ...... Dat, e: 2nd Re~u~t BY:! , , Date: 3rd Re~]u.est BV: , Date: 41:h Reaues! BY;: .... Date: S~ecific Location: Silver Lakes Static Pressure: i Fire F!ow @ 20 psii Residual Main pressure: , 1019, ,Opm Payment Metl~od Check No Inspection~ Fee $35.00 Date Rsc'vcl 4977 E Tamiami Tr. / Naples, FL 34113 I (813) 774-2800 ! FAX (813) 774-3116 TOTAL P. 03 McANLY ENGINEERING AND DESIGN INC. ENGINEERING PLANNING LAND SURVEYING LANDSCAPEARCHITECTURE Project: Silver Lakes RV Project Number: 88776.2 INFILTRATION TESTING & Golf Resort, Phase Two-D Date of Test: 9-25-97 to 9-26-97 Those Present: Willard Herndon - McAnly Engineering and De~qign~ Thc. John Herndon - McAnly Engineering and Design; Tn~_. Description of Line Tested: Sewer extending fromEX MH%~I 3 servicing al 1 Phase Two-D, sewer from MH%31 to PS~3. and sewer from MIq~3zl g.o CALCULATION OF ALLOWABLE INFILTRATION: 2838 (Length of pipe) / 5280' (in feet) ( 2924 ) / 5280' 0 units (occupied) X 0 11 X (diameter of pipe) X 50 gal/day = 161.25 (in inches) X ( 8" ) X 50 gal/day = 221.52 gal/day = 0 382.77 RESULTS OF TEST: Length of Test 24 hour.s, Calculation of Actual Infiltration: Allowable Infiltration Total Gallons 382.77 gallnns 42.3 gallons Test meets project specifications: Engineer: X YES No '" Gina R. Green, P.E. McAnly Engineering and Design, Inc. 5101 TAMIAMI TRAIL EAST, SUITE 202, NAPLES, FLORIDA 34113 (941) 775-0723 FAX (941) 775-9236 RECISION ELECTRIC ~~ of Southwest Florida, Inc. 4273 Arnold Avenue · Naples, Florida 34104 Phone (941) 261-7772 · Fax (941) 261-2161 State Certified # EC0001333 Page 1 DE('EMBER 12_ .1997 FLORIDA S'L;VI'E U%iDERC}ROt.rN 73 ( OMMERC!AL BLYD. NAPI,ES. FI,. 34104 A' I'FE N'I' I O N 'l 'O % ~ lieF: I,iFl STATI()N/SII,VER },AKF;S i~RECIS[ON EI,ECTRiC HAS !NSTA[,[,ED THE ELE(.'TRIC SERVICE T()TIlE I,IFI" S'fA'Fi()N AT SILVER LAK.i,:S. THE SERV1C, E T()'I'Ht]~ LIFT STATION 1~; 130'230 VC)I,T SIN(JlA;: P}tASE., FEI) WITH 1/0 C()PI>ER. TH!:' V(,I ,TA~.'itf DROP F()R TIfF 200 FEET ()F St-,~R ViC'E l, VI'ERA!, ~.H,~. ~t {I-[I; ~ ~ iriP ~i OPERATi(')NS MANAGER cc: li!e 2152 SPRINI BLVD. APOPKA, FL 32703 (407) 886-3'~31 5661 DIVISION DRIVE FORT MYERS, FL 33905 (941) 693-5226 DIVISION OF ELLIS K. PItELPS & CO. RESPOND TO: !3 1100 53RD COURT SOUTH k'~ANGONIA PARK WEST PALM BEACH, FL 33407 (561) 848-2299 PUMP STATION START-UP REPORT JOB NAME SILVER LAKES #3 OPERATOR LOCATION OF STALLATION Naples, fL CONTRACTOR FLORIDA STATE UNDERGROUN~ESIGN CONDITIONS: GPM PUMP MODEL CP3102 H.P. 4 IMPELLER 436 VOLTAGE 230 PHASE SERIAL NUMBER ~1 180-9730704 ~2 180-9730703 #3 t,IAIqUFAC'_PUI.',E]I OF CONTROL L~VI~I{LOAD iil,k:',.tE}! Ii B-28 /~LTtERNATOR TESTED YES COM~IENTS: 63 124 AIRPORT PARK DR. SAVANNAH. GA 31408 (912) 966-1866 Collier County TDIt 1 ~4 QCI SERIAL ¢ 05-97-52 1~/~ C(_)NNF;('TI'2I) YES (2ROUND CONNECq'I:]D YES ~11 controls operate good. Pumps sound good. !-IP~¢;GER CtIECK ~] INF I~,IED INF }~L/~]K INF ~, 2 INF RED INF 13I~/~C }'[ INF ~ 3 RE D 13 LAC K ~ 4 RED BLACK k;OLTAGE CHECK: CONTI(OI, CIIiCU1T ]?I{I/~iART A to B 249 A to G 125 ;~MPEIkAGE CHECK: ff ] 11 A ~2 12 A ii 3 wi{ ITE TO GROUND 125 SECONDARY 24 B to C XX A to C XX }1 to (; 125 ;~ to G XX 12 I~ XX t7 PiiASE 11 [~ XX ('f PliASt-] l"l iCI.A) 'i'E,';'i' I~EI{i:OJ%?,IANCI-] TEST: :~ ] 158.4(;Ptd TI)It fl 2 149.6 GPM ¢ 3 (;I~M TDIt Cf 4 (;PM ,:)l I 2~:Ja] 5;ta~-t-tJ}~ l)ato: 11/17/97 Oi>I'~I>,TCI'Oi-', iI~.S I~]':CI'Z] VI']D 1NSTRtJ(2TI()iq b1?sNtJ£xl, YES COLLIER COUNTY UTILITIES WASTEWATER DEPARTMENT PROJECT VIDEO REVIEW DATE OF REVIEW: 01/05/98 PROJECT NAME: Silver Lakes, Phase 2-D ENGINEER OF RECORD: N/A CONSTRUCTION CONTRACTOR: Florida State Underground VIDEO CONTRACTOR: Sewer Viewer, Inc. COMMENTS: Lines and services are in good condition. RECOMMENDATIONS: '~--~ REVIEW NUMBERED COMMENTS IN ONE YEAR: i I NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) ~ OTHER RECOMMENDATIONS: COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DWISION PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION 2800 NORTtt HORSESHOE DRIVE NAPLES, FL 34104 October 26, 1998 Mr. Shane Parker McAnly Engineering & Design, Inc. 5101 Tamiami Trail East, Suite 202 Naples, FL 34113 RE: Silver Lakes 2-D, Water Dear Mr. Parker: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on October 26, 1998. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418 or Clyde Fugate at (941) 403-2417. Sincerely, Engineering Inspections Supervisor CF/rc/bk/f: cc: Cindy Erb, Engineering Technician, Public Works Timothy L. Clemons, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section Building Review & Perminine Code Enforcement Housing & Urban Improvement (941) 403-2400 (941 ) 403-2440 (941 ) 403-2330 Natural Resources Planning Services Pollution Control (941) 732-2505 (941 ) 403-2300 (941) 732-2502