Loading...
Island Walk, Phase 2MEMORANDUM DATE: February 19, 2000 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II ~' Project Plan Review RE: Island Walk, Phase 2 Water and/or Sewer Facilities Acceptance Recording Fee Number 113-138312-649030 . . , The Board of County Commissioners granted final acceptance of the water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded, in order: 1. Bill of Sale 2. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. e e Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Certification of pressure testing of sewer lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities 10. DER Placement-in-Service letter for sewer facilities Memorandum to Maureen Kenyon, Supervisor, Clerk to Board February 19, 2000 Page Two 11. Contractor's Final Release of Lien 12. Lab results on bacteriological test for water lines 13. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 14. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 15. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 16. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 17. Letter from fire district regarding certification of field fire flow capacity testing 18. Certification of the inflow/infiltration test for the sewer lines by Engineer of Record 19. Coating certification of man holes, wet wells and dry well from manufacturer 20. Copy of video tape test report 21. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations If you have any questions, please call and advise accordingly. attachments doc:2094-2 l)&vight E. Brock Clerk County of Collier CI,ERK OF TIlE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301 TAMIAMI TRAIL EAST P.O. BOX 413044 NAPLES, FLORIDA 34101-3044 OFFICIAL RECEIPT When Validated DESCRIPTION RECi]F;:£~ti',iG OF: t..i::GgL P,.F:,t~I,7,F· F;:ECOF;:Dtr,iG FEE i.]OCtJl~ii~ir, ii"~qF:"t 5]"#~r:iF, S .... BRANCH OFFICES: GOLDEN GATE 4839 GOLDEN GATE PARKWAY GREENTREE SHOPPING CENTER 2386 tMMOKALEE ROAD IMMOKALEE 101 S. FIRST STREET MARCO ISLAND 1040 WINTERBERRY DRIVE EVERGLADES CITY 207 BROADWAY AVENUE AMOUNT DUE :: ..- ..-...-: = ..-. ::: :: ..-.: :: 2.':. '-, ,:} 0 DC :: 2 ;)C!,.., DOC TYP FILE ID BOO}::.' PAGE L..: !i/~.~ L El ," ~::: '"".. - .-.': -" .::' ..' ;:il ~':: 4 i 2 :i .4 t..~ 0 E E i} 2 ~i:'¢ 4 4-> ~. 2 :~:, :! :.21 4 3 DEF' T': 5 E'] L}i::':D '),: i',t(3 TOTAL DUE: 30.70 Prepared by/Return to: William E. Shannon, Esq. 4500 PGA Boulevard, Suite 400 Palm Beach Gardens, F1 33418 2594460 OR: 2641 PG: 3140 RICORI)ID in OFFICIAL RSCORDS of COLLIBR COUNTY, FL 02/16/2000 at I1:19~ DVlGH? N. BROCK, CLIRK R~C ~B 15.00 SHIRLSY Nil BILL OF SALE THIS BILL OF SALE evidencing the sale and conveyance of the water and sewer uti~lity facilities described herein is made this of /~_..~ 1999, by ISLAND WALK DEVELOPMENT COMPANY, day a Florida corporation (hereinafter referred to as "Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). W I T N E S S E T H That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to the Seller in hand paid by the Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: See attached Exhibit A The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims OR: 2641 PG: 3141 and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. Witnesses: ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation Jack B. Oweh, Jr,, V.?.. STATE OF FLORIDA COUNTY OF PALM BEACH The ~oregoing instrument was acknowledged before me this/~3~day of ~/?/~--~' , 1999 by Jack B. Owen, as Vice President of ISLAND WALK D~VELOPMENT COMPANY, a Florida corporation. Notary Public, State of Flori~;' CHRISTINE SCALAMANDRE Commission ~.CC742794 Expires 8 / 31 12002 Notary Public Personally known OR Produced Identification Type of Identification Produced P: \Counsel\CS\ISLANDWK\water-sewer\BillSalePh2. wpd Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (Islandwalk Phase Two) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows: BEGINNING at the Northwest comer of Islandwalk Phase One, as recorded in Plat Book 29, pages 100 through 106, Public Records of Collier County, Florida; thence leaving said comer and along the West line of said Section 33, North 02°11'37" West 950.78 feet; thence leaving said line South 89055'32'' East 486.26 feet; thence South 79°19'22" East 671.00 feet; thence North 65°13'02" East 468.27 feet; thence South 45°21'49" East 672.49 feet; thence North 89000'00'' East 284.83 feet; thence South 01 °00'00" East 505.33 feet; thence South 71°38'14'' West 352.35 feet; thence South 00°01'04" East 460.76 feet to a point on the northerly line of said Islandwalk Phase One; thence along said line in the following seven described courses; 1. South 75000'52" West 710.70 feet; 2. North 82030'37TM West 685.03 feet; 3. North 32038'27'' West 332.65 feet; 4. northwesterly, 244.20 feet along the arc of a circular curve concave to the northeast, having a radius of 1261.00 feet, through a central angle of 11 °05'45" and being subtended by a chord which bears North 27°05'35'' West 243.82 feet; 5. North 89o55'32'' West 117.71 feet; 6. northwesterly, 124.50 feet along the arc of a non-tangential circular curve concave to the northeast, having a radius of 1075.00 feet, through a central angle of 06°38'08" and being subtended by a chord which bears North 15°15'15'' West 124.43 feet; 7. North 89,055'32" East 165.63 feet to the POINT OF BEGINNING of the parcel herein described; Q~i.rii0'g:~7,96 acres more or less; Sfib~ject to easements~.~ and restrictions of record. B~ ~rfli:~,ax-e:~as'sfi:ifi~d:a~d bgsed on the West line of said Section 33 being North 02011'37'' West. ..¢~'..:--.: .: :-..'.¥:, :. . :: : .--:-'.... :i:i~L:O~,~=~ILLERi BARTON'.& PEEK, INC. ~': :: -' <,.::. r' C::, :." .' . . - :-. ~Mar~l, lg/L,. Be~wo,~ .mtj. prOfesslonal Surveyor & Mapper 5086 Not'!~alid Unless embossed with the Professional's seal. W.O.: N-0772-022-000-SSPLT REF.: Islandwalk Phase Two Plat 1~--~- / O1~ / DATE: May 5, 1999 _ PAGES 5/7/9907720021 .MLB WILSON, MILLER, BARTON ~ PEEK, INC. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 ' Ph 941-649-4040 Fx 941-643-5716 Web Site: www. wilsonmiller, com E-mail: naples@wilsonmiller, com Prepared By/Return to: William E. Shannon, Esq. 4500 PGA Boulevard, Suite 400 Palm Beach Gardens, Florida 33418 2594461 OR: 2641 PG: 3143 RgCO~ID in O~ICIJU. RiCORDS of COLLIRR CO~N?~, ~L 02/16/2000 at II:lgAN D#IGH? ~. BROCL CL~RK BN;IN~RIN~ RBVI~¥ SHIRLB! DOC-.70 I§.00 ,70 UTILITY FACILITIES WARRANTY DEED /oa THIS INDENTURE made this day of .~t~ 1999, between ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation (hereinafter referred to as "Grantor"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). W I T N E S S E T H The Grantor, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to the Grantor in hand paid by the Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold, to the Grantee, and Grantee's heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: See attached Exhibit A The Grantor does hereby fully warrant the title to the utility facilities, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A". Grantor and Grantee are used for singular or plural, as the context requires. OR: 2641 PG: 3144 IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. Witnesses Na~e: ~t~ ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation 2~ck B. Owen, Jr., V'P." (CORPORATE SEAL) State of Florida County of Palm Beach The foregoing Utility /O~-'AFacilities Warran~,/,.~__Deed was acknowledged before me this day of ~/~/~--~-~/ , 1999 by Jack B. Owen, Jr. Vice President of ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation. Notary Public. State of Florida CHRISTINE SCALAMANDRE Commission #. CC742794 Expires 8131 12002 Notary Public Personally known ~J- OR Produced Identification Type of Identification Produced ?: \Counsel \CS\ ISLANDWK\water- sewer \WarrantyDeedPh2. wpd PLANNERS, ENVIRONMENTAL CONSULTANTS, ENGINEERS, SURVEYORS, LANI')S(~'APE AP, CItlTEC'.TS, (~ONSrI B.U£~'TiL>N Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (Islandwalk Phase Two) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows: BEGINNING at the Northwest comer of Islandwalk Phase One, as recorded in Plat Book 29, pages 100 through 106, Public Records of Collier County, Florida; thence leaving said comer and along the West line of said Section 33, North 02°I 1'37" West 950.78 feet; thence leaving said line South 89o55'32" East 486.26 feet; thence South 79°19'22" East 671.00 feet; thence North 65°13'02" East 468.27 feet; thence South 45°21'49" East 672.49 feet; thence North 89o00'00'' East 284.83 feet; thence South 01 °00'00" East 505.33 feet; thence South 71°38'14.' West 352.35 feet; thence South 00o01'04'' East 460.76 feet to a point on the northerly line of said Islandwalk Phase One; thence along said line in the following seven described courses; 1. South 75000'52'. West 710.70 feet; 2. North 82o30'37.' West 685.03 feet; 3. North 32°38'27'' West 332.65 feet; 4. northwesterly, 244.20 feet along the arc of a circular curve concave to the northeast, having a radius of 1261.00 feet, through a central angle of 1 l°05'45.' and being subtended by a chord which bears North 27°05'35" West 243.82 feet; 5. North 89055'32.' West 117.71 feet; 6. northwesterly, 124.50 feet along the arc of a non-tangential circular curve concave to the northeast, having a radius of 1075.00 feet, through a central angle of 06038'08" and being subtended by a chord which bears North 15°15'15" West 124.43 feet; 7. North 89o55'32" East 165.63 feet to the POINT OF BEGINNING of the parcel herein described; Containing 67.96 acres more or less; Subject to easements and restrictions of record. Bearings are assumed and based on the West line of said Section 33 being North 02°I 1 '37" West. X~iLSON, MqLLER, BARTON & PEEK, INC. Marcus ~. Bem~an,'B-ofessional Surveyor & Mapper Florida Registration No. 5086 Not valid unless embossed with the Professional's seal. W.O.: N-0772-022-000-SSPLT PA~J~ REF.: Islandwalk Phase Two Plat DATE: May 5, 1999 WILSON, MILLER, BARTON ~5~ PEEK, INC. 3200 Bailev Lane, Suite 200, Naples, Florida 34105-8507 ° Ph 941-649-4040 Fx 941-643-5716 \X/eb Site: www.wilsonmiller, com E-mail: naples@wilsonmtller, com OWNER' S AFFIDAVIT STATE OF FLORIDA COUNTY OF PALM BEACH BEFORE ME, the undersigned authority, personally appeared Jack B. Owen, Jr. as Vice President of ISLAND WALK DEVELOPMENT COMPANY, who to me is well known, and having been duly sworn and under oath, deposes and states: 1. My name is Jack B. Owen, Jr., I am over the age of twenty-one (21) years, am sui juris, and have personal knowledge of the facts contained herein. 2. I am the owner of said real property located at Island Walk, and legally described on Exhibit "A". 3. Ail persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of water and sewer utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. 4. No claims have been made to the Owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. 5. The utility facilities described herein are not included in, encumbered by, or subject to any real property mortgage, chattel mortgage, security agreement, Uniform Commercial Code financing statement, or any other encumbrance. 6. As and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A". ISLAND WALK DEVELOPMENT COMPANY, a Florida corporation Jack B. Owen, Jr, V P AFFIANT State of Florida County of Palm Beach SUBSCRIBED AND SWORN to before me this of ~'?~/ , 1999 by Jack B. President ~f Island Walk Development corporation. /O-~' day Owen, Jr., as Vice Company, a Florida Notary Public State of Florida CHRISTINE SCALAMANDRE Commission #. CC742794 Expires 8131 / 2002 Notary Public Personally known/~/ OR Produced Identification Type of Identification Produced Prepared By: William E. Shannon, Esq. 4500 PGA Boulevard, Suite 400 Palm Beach Gardens, Florida 33418 P: \Counsel\CS \ I SLANDWK\water-sewer \OwnerAffPh2, wpd PLANNERS, F_NVIRONMENTAL CONSUI_TANTS, ENGINEERS, SLJRVEY(3RS, LAN I>S£:AP[.; Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (Islandwalk Phase Two) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows: BEGINNING at the Northwest comer of Islandwalk Phase One, as recorded in Plat Book 29, pages 100 through 106, Public Records of Collier County, Florida; thence leaving said comer and along the West line of said Section 33, North 02°11'37" West 950.78 feet; thence leaving said line South 89055'32'' East 486.26 feet; thence South 79° 19'22" East 671.00 feet; thence North 65°13'02" East 468.27 feet; thence South 45°21'49" East 672.49 feet; thence North 89000'00'' East 284.83 feet; thence South 01000'00'' East 505.33 feet; thence South 71°38'14'' West 352.35 feet; thence South 00°01'04" East 460.76 feet to a point on the northerly line of said Islandwalk Phase One; thence along said line in the following seven described courses; 1. South 75°00'52'' West 710.70 feet; 2. North 82°30'37'' West 685.03 feet; 3. North 32038'27'' West 332.65 feet; 4. northwesterly, 244.20 feet along the arc of a circular curve concave to the northeast, having a radius of 1261.00 feet, through a central angle of 11°05'45'' and being subtended by a chord which bears North 27005'35'' West 243.82 feet; 5. North 89055'32'' West 117.71 feet; 6. northwesterly, 124.50 feet along the arc of a non-tangential circular curve concave to the northeast, having a radius of 1075.00 feet, through a central angle of 06°38'08" and being subtended by a chord which bears North 15°15'15'' West 124.43 feet; 7. North 89055'32'' East 165.63 feet to the POINT OF BEGINNING of the parcel herein described; Containing 67.96 acres more or less; Subject to easements and restrictions of record. Bearings are assumed and based on the West line of said Section 33 being North 02°11'37" West. WILSON, MILLER, BARTON & PEEK, INC. Mar,us'~. B~.an,' Professional Surveyor & Mapper Florida Registxation No. 5086 Not valid unless embossed with the Professional's seal. W.O.: DATE: N-0772-022-000-SSPLT Islandwa~ Phase Two Plm May 5, 1999 . WILSON, MILLER, BARTON ~. PEEK, INC'. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 ' Ph 941-649-4040 Fx 941-643-5716 Web Site: www. wilsonmiller.com E-mail: naples@wilsonmiller, com ATTORNEY'S AFFIDAVIT STATE OF FLORIDA COUNTY OF PALM BEACH BEFORE ME, the undersigned authority, personally on this ~-~ day of ~ 1999, appeared WILLIAM E. SHANNON, who to me is well known, and having been sworn and under oath, deposes and states: 1. My name is WILLIAM E. SHANNON, I am over the age of twenty-one (21) years, am otherwise sui juris, and have personal knowledge of the facts contained herein. 2. I am a licensed attorney, Florida Bar #202363 authorized to practice law and am practicing law in the State of Florida. My business address is 4500 PGA Boulevard, Suite 400, Palm Beach Gardens, Florida 33418. My business telephone number is (561) 627-2112. My business mailing address is 4500 PGA Boulevard, Suite 400, Palm Beach Gardens, Florida 33418. 3. This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District to accept the dedication or conveyance of water and sewer utility facilities located within or upon the real property described in the attached Exhibit "A", which is incorporated herein by referenced, said land being located in Collier County, Florida. 4. The Affiant has examined record title information to both the real and personal property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 5. The record owner of the real and personal property described herein is Island Walk Development Company, a Florida corporation, ("Owner") current and active and authorized to do business within the State of Florida. The Owner acquired record title to the subject real property by instrument recorded at Official Records Book 2331, at Page 2134, of the Public Records of Collier County, Florida (copy attached hereto as Exhibit "B" incorporated herein by reference). Persons authorized to execute instruments on behalf of Island Walk Development Company in conjunction with the conveyance of the subject property include but is not limited to; William E. Shannon, President; Jack B. Owen, Jr., Vice President/Secretary/Treasurer; and Michael D. Rosen, Vice President. 6. Affiant has examined the Articles of Incorporation of the Owner and the Certificate of Incorporation issued by the Secretary of State for the State of Florida. The corporation is current and active within said State and is currently authorized to do business in the State of Florida. Jack B. Owen, Jr., as Vice President of Island Walk Development Company, is authorized to execute the instruments on behalf of Island Walk Development Company, in conjunction with the conveyance of any interest in the subject real and personal property. by: The subject real and personal property are encumbered NONE except as specifically noted herein, all of the Public Records of Collier County, Florida. 8. Affiant further states that the information contained in this Affidavit is true, correct and current as of the date this Affidavit is given. FURTHER AFFIANT SAYETH NAUGHT. DATED this ~ day of , 1999. William E. Shannon SUBSCRIBED AND SWORN to before me this ~ d a y o f ~ow~~ ~/~c~-~^~u me. , 1999 by William E. Shannon, who is personally ~/No t a r y Public Notary Printed Name Prepared By/Return To: William E. Shannon, Esq. 4500 PGA Boulevard, Suite 400 Palm Beach Gardens, Florida 33418 P:\Counsel\CS\ISLANDWK\water-sewer\attorneyaffPH2.wpd PLANNERS, ENV'tRONMENTA1. (~ONSUI.TANTS, F_NGINEERS, SURVEYORS, I_ANDS(;AI'E Af*,(D~II'¥E(.'TS, (]ONSTRUC;TI()N M:\NAtiliI~5 Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (Islandwalk Phase Two) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows: BEGINNING at the Northwest comer of Islandwalk Phase One, as recorded in Plat Book 29, pages 100 through 106, Public Records of Collier County, Florida; thence leaving said comer and along the West line of said Section 33, North 02°11'37" West 950.78 feet; thence leaving said line South 89°55'32'' East 486.26 feet; thence South 79019'22'' East 671.00 feet; thence North 65013'02'' East 468.27 feet; thence South 45o21'49'' East 672.49 feet; thence North 89°00'00'' East 284.83 feet; thence South 01 °00'00" East 505.33 feet; thence South 71°38'14'. West 352.35 feet; thence South 00°01'04" East 460.76 feet to a point on the northerly line of said lslandwalk Phase One; thence along said line in the following seven described courses; 1. South 75000'52" West 710.70 feet; 2. North 82030'37'' West 685.03 feet; 3. North 32038'27'' West 332.65 feet; 4. northwesterly, 244.20 feet along the arc of a circular curve concave to the northeast, having a radius of 126 i .00 feet, through a central angle of 11°05'45'. and being subtended by a chord which bears North 27005'35'. West 243.82 feet; 5. North 89055'32.. West 117.71 feet; 6. northwesterly, 124.50 feet along the arc of a non-tangential circular curve concave to the northeast, having a radius of 1075.00 feet, through a central angle of 06°38'08'' and being subtended by a chord which bears North 15°15'15'' West 124.43 feet; 7. North 89055'32" East 165.63 feet to the POINT OF BEGINNING of the parcel herein described; Containing 67.96 acres more or less; Subject to easements and restrictions of record. Bearings are assumed and based on the West line of said Section 33 being North 02°11'37" West. wiLsoN, MILLER, BARTON & PEEK, INC. Marcus'~.. Be~an,'h'ofessional Surveyor & Mapper Florida Registration No. 5086 Not valid unless embossed with the Professional's seal. W.O.: DATE: N-0772-022-000-SSPLT Islandwalk Phase Two Plat May 5, 1999 WILSON, MILLER, BARTON ~t PEEK, IN('.. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 ' Ph 941-649-4040 Fx 941-643-5716 Web Site: www. wilsonmiller.com E-mail: naples@wits~mmillcr.com ~his Instrument Prepared By and Please Return To: JOHN F.,STEWART SHEPPARD, BRETT, STEWART & HERSCH', P.A. 2121 West First Sffeet P. O. Drawer 400 Fort Myers, Florida 33902 2205889 OR: 2331 PG: 2134 RECORDRD in OFFICIAL RECORDS of C0LLIRR COUNTY, FL 07/16/97 at 11:29~ DNIGH? E. BROCK, CLERK P 0 DRANBR 400 CONS 6996895.00 l~C FE~ 15.00 DOC-.70 48~'78.30 Grantee(s) S.S. # ~,~ THIS WARRANTY DEED, made this I,~' -" day of ~---',,_~; }; 1997, between Harvey Bros. Farms, Inc., a Maryland Corpdration whose post office address is: 900 N. Logan Blvd. Naples, Florida 33999 hereinafter called the grantor, to Island Walk Development Company, a Florida Corporation whose post office address is: 4500 PGA Blvd. Suite 400 Palm Beach Gardens, Florida 33418 hereinafter called the grantee: (Wherever used herein the terms "grantor" and "grantee" include all the parties to this instrument and the heirs, legal representatives and assigns of individuals, and the successors and assigns of corporations) WITNESSETH, that the grantor, for and in consideration of the sum of $10.00 and other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys and confirms unto the grantee all that certain land situate in Collier County, State of Florida, viz: SEE SCHEDULE "A" ATTACHED Subject to easements, restrictions and reservations of record, if any, and oil, gas and/or mineral rights set forth in Deed Book 30, Page 91 and Deed Book 34, Page 260 of the Public Records of Collier County, Florida, and taxes for 1997 and subsequent years. Property Appraiser's Parcel Identification Number: a portion of Strap #203200005 TOGETHER, with all the tenements, hereditaments and appurtenances thereto PAGES OR: 2331 PG: 2135 TO HAVE AND TO HOLD, the same in fee simple forever. AND the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful auth°ri~'¥0~ell'and convey said land, and hereby warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes accruing subsequent to December 31, 1996. IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day and year first above written. Signed, Sealed and Delivered in Our Presence: Witn~ ~i~(~attlre ' SHERRY L. NORRIS ame of Witness i ess~lg'~ (~/es~ ~0hn F Stewad Printed Name of Witness Harvey Bros. Farms, Inc., a Maryland Corporation Fred R. Harvey, Presid~.~)~ STATE OF FLORIDA COUNTY OF LrCOJ The foregoing instrument was acknowledged before me this iv - day of ,1997, by FRED R. HARVEY, President of Harvey Bros. Farms, Inc., a Maryland Corporation who is personally known to me or who has produced /o fPv as identification. (Seal) -'. Printed Notary Signature PLAI':N SCHEDULE III I AC] E KS Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (173.11 +/- Acre Parcel) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows; COMMENCING at the southwest comer of said Section 33; thence along the west line of said Section 33, North 01°23'36" West 170.13 feet to a point on the north right of way line of Vanderbilt Beach Road (C.1L 862) and the POINT OF BEGINNING of the parcel herein described; thence continue along said west line North 01°2Y36" West 2587.71 feet; thence leaving said west line South 89°07'32" East 2914.97 feet; thence South 00°46'57'' West 1404.85 feet; , thence South 06030'53" East 444.52 feet; thence South 03o07'54'' West 277.90 feet; thence southerly, southeasterly and easterly, 461.18 feet along the arc of a circular curve concave northeasterly, having a mdins 286.50 feet, through a central angle of 92°13'48" and being subtended by a clmrd which bears South 42°59'01' East 412.98 feet; thence South 89005'55" East 38.62 feet; thence South 47°46'33" East 114.31 feet; thence South 00054'05" West 90.00 feet to a point on file north right of way line of Vanderbilt Beach Road (C.IL 862); thence along said line North 89o05'55" West 620.01 feet; thence continue along said line North 89o06'26TM West 1322.86 feet; thence continue North 89°06'49'' West 1328.72 feet to a point on the west line of said Section 33 and the POINT OF BEGINNING of the parcel herein described. Containing 173.11 acres more or less. Subject to easements and restrictions of record. Bea.4ngs are assumed and based on the west line of said Section 33 being North 01o23'36" West. WILSON, MILLER, BARTON & PEEK, INC. 3os~h/ff. BoM, .Professio~ml Surv~Or.,~per Fl{~ Regi~mtion No. 3516 t/b/ Not valid Unless embossed with the Professional's seal. W.O.: N-0772-011-00 I-PSCAL REF.: 4L-1401 DATE: April 16, 1997 Revised May 2, 1997 Revised May 16, 1997 Revised June 4, 1997 Revised June 13, 1997 PA61tS 6/I 3/97-07720001 .mlb WILSON, MILLF. P,, 13^p,-roN & [>EEK, INC. 3200 Bailcy [_:mc, Suite 200, Naples, FIo,'ida 341 O5-8507 · Ph 941-649-4040 Fx 94 [ -643- 5716 Wcl~ She: www. wilsomuillcr.c(~m E-mail: naplc's~wilsonmiller.com ~ O0 ,t-0 This Instrument Prepared By ,,% ~ '.~oand Please Return To: ~'/2q~' JOHN F. STEWART ~ b, SHEPPARD, BRETT, STEWART & HERSCH, P.A. 2121 West First Street P. O. Drawer 400 Fort Myers, Florida 33902 23 ,x 54 OR: 2441 PG: 2776 ~ECORDED in OFFICIAL RECORDS of COLLIER COURT¥, ~L 07/16/98 at 0~:23PM DWIGHT E. BROCK, CLERK CONS 7612050,00 He HB 15.00 DOC-.70 53284.?0 Retn: 8HBPPARD BRBTT BT AL P 0 DRANER 400 Grantee(s) S.S. #65-0663645 THIS WARRANTY DEED, made this c~ day of 1998, between Harvey Bros. Farms, Inc., a Maryland corporation whose post office address is: 7373 Vanderbilt Beach Road Extension Naples, Florida 34119 hereinafter called the grantor, to Island Walk Development Company, a Florida corporation whose post office address is: 4500 PGA Blvd. Suite 400 Palm Beach Gardens, Florida 33418 hereinafter called the grantee: (Wherever used herein the terms "grantor" and "grantee" include all the parties to this instrument and the heirs, legal representatives and assigns of individuals, and the successors and assigns of corporations) WlTNESSETH, that the grantor, for and in consideration of the sum of $10.00 and other valuable considerations, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys and confirms unto the grantee all that certain land situate in Collier County, State of Florida, viz: SEE SCHEDULE "A" ATTACHED Subject to easements, restrictions and reservations of record, if any, and oil, gas and/or mineral rights set forth in Deed Book 30, Page 91 and Deed Book 34, Page 260 of the Public Records of Collier County, Florida, and taxes for 1998 and subsequent years. Property Appraiser's Parcel Identification Number: a portion of Strap #00203200005 TOGETHER, with all the tenements, hereditaments and appurtenances thereto belonging or in anywise appertaining. PA61tS TO HAVE AND TO HOLD, the same in fee simple forever. AND the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in fee simple; that the grantor has good right and lawful authority to sell and convey said land, and hereby warrants the title to said land and will defend the same against the lawful claims of all persons whomsoever; and that said land is free of all encumbrances, except taxes accruing subsequent to December 31, 1997. IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day and year first above written. Signed, Sealed and Delivered in~,O~nce: WitnX0s L. NORRIS Pdnte~ame of Wi.~me.~,ff ~ ~ ,JOhn F. Stevrart Printed Name of Witness Harvey Bros. Farms, Inc., a Maryland corporation BY: ~Fred'~R. H/~arve~y,~ STATE OF FLORIDA COUNTY OF ~ The foregoing instrument was acknowledged before me this ;2s~_ day of ,1998, by FRED R. HARVEY, President of Harvey Bros. Farms, Inc., a Marylanc~ corporation who is personally known to me or who has produced t,3/A as identification. (Seal) N--~ry Public ~ ~ ' ~ SHERRY L, NOR_alS Printed Notary Signature SCHEDULE "A" Description of part of Section 33, Township 48 South, Range 26 East, Collier County, Florida. (182.07 +/- Acre Parcel) All that part of Section 33, Township 48 South, Range 26 East, Collier County, Florida being more particularly described as follows: COMMENCING at the Southwest comer of said Section 33; thence along the West line of said Section 33, North 02° 11' 37" West 170.13 feet to a point on the North right of way line of Vanderbilt Beach Road (C.R. 862); thence continue along said West line North 02° 11' 37" West 2587.71 feet to the POINT OF BEGINNING of the parcel herein described; thence continue North 02° 11' 37" West 2587.71 feet to the Northwest comer of said Section 33; thence along the North line of said Section 33, South 89° 56' 27" East 2644.18 feet to the North 1/4 comer of said Section 33; thence along the North-South 1/4 line of said Section 33, South 02° 11' 58" East 1818.59 feet; thence South 89° 55' 32" East 555.29 feet; thence South 00° 08' 23" West 581.05 feet; thence South 89° 55' 32" East 431.74 feet; thence South 00° 08' 23" West 1060.39 feet thence North 89° 55' 32" West 682.71 feet; thence North 00° 01' 04" West 872.22 feet; thence North 89° 55' 32" West 2914.97 feet to a point on the West line of said Section 33 and the POINT OF BEGINNING of the parcel herein described. Containing 182.07 acres more or less. Subject to easements and restrictions of record. Bearings are assumed and based on the West line of said Section 33 being North 02° 11' 37" West. PAG]~ (/~/, OF c~y PAGIaS COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 ENGINEERING REVIEW SECTION August 13, 1999 Mr. Allen Witt, P.E. Wilson Miller 3200 Bailey Lane Naples, FL. 34105 Re: Island Walk Phase Two Dear Allen: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, John R. Houldsworth Senior Engineer cc: Shirley Nix Phone (941) 403-2400 Fax (941) 643-6968 www.co.collier.fl.us COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION September 17, 1999 Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 Allen Witt Wilson, Miller, Barton & Peek, Inc. 3200 Bailey Lane Naples, FL 34105 Re: Island Walk, Phase Txvo Dear Mr. Witt: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we ma3' be of assistance, please advise. Very truly yours, / ,,-"i'.': ' -; ~ ' Shirley Nix (.__.-/ Engineering Technician II Joe Cheatham, Wastewater Director Paul Mattausch, Water Director Cindy Erb, Public Works John Houldsworth, Engineering Review Phone (941) 463-2400 Fax (941) 643-6968 www. co.collier, fl. us WilsOnMiller New Directions In Planning, Design & Engineering June 21, 1999 Mr. Thomas Kuck, P.E. Project Plan Review Collier County Development Services Center 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: IslandWalk Phase Two Utility Dedication Engineer's Payment Confirmation Collier County Conveyance Document Checklist, Legal Docurnent Item 16 Dear Mr. Kuck: Wilson Miller confirms receiving payment for our services to date on the subject project. this date, no monies are outstanding from the owner/client. Sincerely, WILSONMILLER, IN(?. F. Allen Witt, P.E. Project Manager As of Naples Fort Myers Sarasota Bradenton Tampa 3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 www. wilsonmiller, corn WilspnMiller New Directions In Planning, Design & Engineering June 21, 1999 Ms. Shirley Nix Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: IslandWalk Phase Two Utility Testing Results Dear Ms. Nix: The following attached tests for the subject project are in our professional judgment and to the best of our knowledge and belief representative of actual field conditions on the date performed: 1. 6" and 8" watermain pressure test, dated May 11, 1999 2. Inflow/infiltration test, dated May 6"' and May 11, 1999 If you should have any questions, please do not hesitate to contact our office. Sincerely, WILSONMILLER, INC. F. Allen Witt, P.E. Project Manager Enclosures Engineer s Signature and Sea! Naples Fort Myers Sarasota Bradenton Tampa 3200 Bailey Lane, Suite 200 Naples, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 www. wilsonmiller, corn HYDROSTATIC TEST REPORT The computed allowable leakage fi)r the test section is (calculations attached) The maintained test pressure tbr the test duration was The measured leakage during the test was 7_. Meter The duration of the test was The measured leakage was The method of measurement was Type of Main w.o. Plan File Supt. Field Rep. Date of Test Gal. Hrs. Gal. Hr. Calibrated Drum the allowable leakage. The hydrostatic test for this section meets ~ does not meet psi. WILSON, MILLER, BARTON & PEEK, INC. By: (~~, ?'f~ ~W-~- Date: Fieg;f Representative 12/2/94-00110036.BKY zoo HYDROSTATIC TEST REPORT Proj ect-./';"""/,~na/O..)a//~' -~ lq ~ Type of Main L,~~ w.o. # 3./o Date of Test ._.~...[/.~c'~ The computed allowable leakage for the test section is (calculations attached) The maintained test pressure for the test duration was ! ~ The measured leakage during the test was (3, ~)CO Gal. Gal. Hr. psi. The duration of the test was 7_~. Hrs. The measured leakage was Gal. Hr. The method of measurement was Meter The hydrostatic test for this section Calibrated Drum meets ~. does not meet the allowable leakage. WILSON, MILLER, BARTON & PEEK, INC. By: 7eld Representative ' e"~' Date: 1212194-00110036. BK Y HYDROSTATIC TEST REPORT Project ~---'~C/Or<4 Lt.)ca [[< ,~te.~ ~' Type of Main ~~ /~ )~/32 Plan File ~-- 0~-- /~ Supt. x_J~ ~ct)~ ~ot'] Field Rep. ~0/~ /YA ~ Date of Test ~ - //- 99 The computed allowable leakage tBr the test section is (calculations attached) ~, ~ ~ Gal. Hr. The maintained test pressure for the test duration was /~ ~ psi. The measured leakage during the test was ~, ~ Gal. The duration of the test was The measured leakage was The method of measurement was The hydrostatic test for this section meets kg' does not meet Hrs. Gal. Hr. Meter Calibrated Drum the allowable leakage. WILSON, MILLER, BARTON & PEEK, INC. Field Representative E-~I- qq 12t2/94-00110036. BKY HYDROSTATIC TEST REPORT Type of Main w.o. ~ ~ Fiela Rep. Date of Test The computed allowable leakage for the test section is (calculations attached) The maintained test pressure for the test duration was /~ ~) The measured leakage during the test was ~,~."~' "'~.,;,, Gal. ,-- (3,70 ca. Hr. psi. The duration of the test was The measured leakage was The method of measurement was The hydrostatic test for this section meets 5~ does not meet Hrs. Gal. Hr. Meter Calibrated Drum the allowable leakage. WILSON, MILLER, BARTON & PEEK, INC. Find Representative Date: 12/2/94-00110036.BKY Jeb Bush Governor Department of Environmental Protection South District P.O. Box 2549 Fort Myers, Florida 33902-2549 David B. Struhs Secretary July 14, 1999 Michael D. Rosen, Land Development Manager SunCo Building Corporation 6005 Vanderbilt Beach Road Naples, Florida 34119 Re: Collier County - PW IslandWalk Phase Two (Collier County Regional WTP) 151942-001-DSGP Dear Mr. Rosen: This acknowledges receipt of certification that the subject water distribution system extension has been completed in accordance with the plans and related materials permitted by this agency under Permit Number 151942-001-D S GP dated March 15, 1999. Based on this certification and satisfactory bacteriological results, we are approving these facilities for service under the following conditions: If the bacteriological samples were collected prior to replacement of the temporary backflow preventer or temporary construction meter with a final connection, then additional bacteriological sampling is required. Upon completion of the final connection, collect a bacteriological sample immediately downstream of the connection and submit the bacteriological results to the Department. Immediate service can be provided if a precautionary boil water notice is issued for areas down stream of the connection, until one day of satisfactory bacteriological results have been obtained (Two consecutive days of satisfactory bacteriological results are required following any unsatisfactory result). Your continued cooperation in our water supply program is appreciated. Sincerely, CRD/MFJ/skw cc: F. Allen Witt, P.E. Thomas E. Kuck, P.E. Charles R. Davault Professional Engineer Water Resource Management "Protect, Conserve and Manage Florida's Environment and Natural Resources" Printed on recycled paper. SEP-1~-1999 08:53 WILSONMILLER SURUEY 941 643 6682 P.02/02 Florida Department of Environmental Protection Twin Towo~ Office Bldg., 2600 Blair gton~ Road, Tallahass~, Florida 3_399-..400,.- -- ~ ~ ~ ~ .... WILSON MILL_~R SEP ! 0 ~9~9 DORIC WASTEWATER COLLECTION/TRANSMISSION SYSWEMS ......... CERTIFICATION OF COMPLETION OF CONSTRUCTION INSTRUCTIONS: This form is to bo compl*tcd and submitted to thc Department, prior to placing the system into operation. A co[l~otion/tmngmission system should not b~ placed into open, lion without prior D~partment approval ^11 information is to be typed or printed in ink and all blanks must be filled, o Construction Portrdt No 5_0_S8 ir 106-DWC Dated: _ March 15,.1999 Name of Project ls~landW, alk, Pha.~.~ '2_ Name of Owner: SunCo B, uildine Cprporation Name of design engineer and Florida r~gistration number (if dif'f~rent t¥om engineer signing certification): Date(s) connection to existing system or treatment plant: Treatment plant serving prqiect Name: North Re~,ional. Wast~water Treatnlent Plant County: Collier City: . N/,A DEP Identification Number (also known as WAFR or OMS Identification Nu: Substantial d~viations from the approved plans and speaifications (attach See attached rex:or.d drawines. ): FLS 0141.~9 ii: r~quir~d): AU6 1 2 1999 TOTAL P.02 FINAL RELEASE OF LIEN KNOW ALL MEN BY THESE PRESENTS: That the undersigned, for and in consideration of the payment of the sum of TEN DOLLARS (10.00) paid by, SUNCO BUILDING CORP. Contractor, receipt of which is hereby acknowledged, hereby releases and quit claims to the said, ISLAND WALK DEVELOPMENT CO., Owner, its successors and assigns, all liens, lien rights, claims or demands of any kind whatsoever, which the undersigned now has or might have against the building on premises legally described as: ISLAND WALK PHASE II A PORTION OF LAND LYING IN SECTION 33, TOWNSHIP 48S, RANGE 26E AS RECORDED N.O.C. OR BOOK 2460, PAGES 3173-3174 COLLIER COUNTY, FLORIDA on account of labor performed and/or material furnished for the construction of any improvements thereon. That all labor and materials used by the undersigned in the erection of said improvements have been fully paid. IN WITNESS WHEREOF, I have hereunto set my hand and seal/t~;15th day of September, 1999 WITNESSES: FLORIDA STATE U,~fll~. RGROUND, INC. ~_ ~) ~'~..~) -~ Yh~OM~-~P ~M/V~resident STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was acknowledged before me this 15th day of September, 1999 by Thomas P. McKimm, on be361f of the company who is personally known to me and did not take ~ath.~ ~ ~/~~', ,~4~i~t . My Commission Expires: NOTA/J(Y Notary Public - State of Florida My comm. expires Sept 19, 2001 Comm. No. CC670403 State of FLorida Department of Health Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS !FOR LAB USE ONLY SYSTEM NAME: ADDRESS: COLLECTOR: Press hard, (5) copies SYSTEM I.D. NO: i' COUNTY: SYSTEM PHONE #: DISTRICT: ' ~ ~:? .~.!' ! : I SAMPLE SITE (Locality or Subdivision): COLLECTOR PHONE #: i DATE AND TIME COLLECTED: '~,, r;~,':> ':/ ~' ~, :F~:~:' TYPE OF SUPPLY(Circ[e one): ,:::Conl~Q~i~y ~a~r SYst~::~Noncorl~nunity water system Nontransient - noncommunity water system ~Ff~t~"~I[ ..... '~n~ning pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement '~' ~M~'~n Clearance Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB ANALYSIS METHOD: ~_~'MF~? MTF HMO-MUG PA COLL. SAMPLE POINT Cl NON CONF]RM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLt SAMPLE NUMBER * Results in this column are presumptive. P - Coliforms are present A - Coliforms are absent Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER o~ NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVEREPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORI~ATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of FLorida Departaent of Health Office of Laboratory Services Jacksonville, #iaai, Pensacola Ta~:m, West Perm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS ~/~:~',.-~FOR LAB USE ONLY SYSTEM NAME: ADDRESS: Press hard, (5) copies COLLECTOR: ~. :i!~ SAMPLE SiTE (LocaJity or Subdivision): DATE AND TIME COLLECTED: SYSTEM I.D. NO: ~, ~, i: COUNTY: SYSTEM PHONE #: DISTRICT: COLLECTOR PHONE #: TYPE OF SUPPLY(Circle one):~comm~it~-wa~r ~&~:, Noncommunity water system Nontransient - noncommunity water system 'P'rfva~ewe[-[ ....... S~f~n~n~g pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement ~ ..... M;in ~[ea~n~:,~ we[[ survey Other (Check Box) ' ~ ..................... [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE T.Q BE COMPLETED BY LAB ANALYSIS METHOD:~/' M'~'i. MTF HMO*MUG PA COLL. SAMPLE POINT Cl NON ~-~JN F I RM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. LOLl SAMPLE NUMBER i * Results in this column are presumptive. P - Co[iforms are present A - Co[iforms are absent Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. C - Confluent growth TA - Turbid, Absence of gas or acid TNTC- Too numerous to count INVOICE ADDRESS (if different than address be[ow): :ce° NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE'REPORT REVIEWING OFFICIAL: TITLE: INTERPRETATIONS-RE)LARKS BY. PROGRAM REVIEWER ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES FLORIDA STATE UNDERGROUND, INC, CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: ISLAND WALK PHASE 2 DATE: June 15, 1999 THIS IS A: WATER SYSTEM X SEWER SYSTEM ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST AIR RELEASE VALVE 1 EA 1,300.00 1,300.00 PVC C900 CL 150 6" 3588 LF 7.15 25,654.20 PVC C900 CL 150 8" 2670 LF 9.63 25,712.10 PVC C900 CL 200 8" 120 LF 10.45 1,254.00 DOUBLE SERVICE 91 EA 392.00 35,672.00 SINGLE SERVICE 3/4" 9 EA 270.00 2,430.00 FIRE HYDRANT 13 EA 1,745.00 22,685.00 GATE VALVE W/BOX 6" 4 EA 446.00 1,784.00 GATE VALVE W/BOX 8" 5 EA 590.75 2,953.75 PBSP 4 EA 795.00 3,180.00 TOTAL 122,625.05 I DO HEREBY CERTIFY THE ABOVE DESCRIBED LIST OF MATERIALS, QUANTITIES OFMATERIALS, KINDS OF MATERIALS, INCLUDING INSTALLATION AND ALL COSTS AS INSTALLED, TO BE COMPLETE, TRUE AND ACCURATE AS PER FINAL PAY ESTIMATE AND/OR ALL INVOICES OR STATEMENTS OF (BY OR FROM) THIS CERTIFYING CONTRACTOR AND AS PER THE PROJECT AND/OR DESIGN ENGIN~RS CERTIFIED RECORD DRAWINGS OF THIS SYSTEM AS DESCRIBED BY NAME SHOWN,, AS OF THIS D?~I'/. // PERSONALLY KNOWN, SWORN TO CERTIFYINg,a/)t .t & SUBSCRIBED BEFORE ME THIS '<..~.....~~_~...~/'/~ ~ -~ ...... _~-~-~ t~ 1099 ThOh&~ff'~..~. PRE S IDENT I · ,r-~_g2'u~~ida I (SEAL) FLORIDA STATE UNDERGROUND, INC, CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS & COSTS SYSTEM NAME: ISLAND WALK PHASE 2 DATE: June 15, 1999 THIS IS A: WATER SYSTEM SEWER SYSTEM X ITEM DESCRIPTION SIZE QUANTITY UNIT COST TOTAL COST PVC SDR26 045 8" 1626 LF 13.35 21,707.10 PVC SDR26 6-8 8" 1334 LF 20.72 27,640.48 PVC SDR26 8-10 8" 1226 LF 26.50 32,489.00 SDR 26 10-12 8" 554 LF 66.70 36,951.80 SDR 26 12-14 8" 713 LF 86.00 61,318.00 SDR26 14-16 8" 361 LF 86~00 31,046.00 MANHOLE 0-6 6 EA 1,050.00 6,300.00 MANHOLE 6-8 6 EA 1,332.00 7,992.00 MANHOLE 8-10 3 EA 1,578.00 4,734.00 MANHOLE 10-12 2 EA 1,825.00 3,650.00 MANHOLE 12-14 2 EA 2,317.00 4,634.00 MANHOLE 14-16 1 EA 2,915.00 2,915.00 SINGLE SERVICE 19 EA 322.90 6,135.10 DOUBLE SERVICE 86 EA 355.75 30,594.50 PVC F.M. C900 CL100 8" 1160 LF 7.65 8,874.00 PLUG VALVE 8" 1 EA 1,041.75 1,041.75 TOTAL 288,022.73 I DO HEREBY CERTIFr rile ~4BOVE DESCRIBED lIST OF~4rEm,~ZS, QU.q~vrlrlES OFMATERI.4LS, KINDS OF mr~m~s, INCtt~Dm~ INSrm~rION ~ND ~ COSrS ~S msr~tze~, ro ~ co~z~r~, r~ ~cc~r~ ~s w~ ~i~z mr ~m r~ ~/o~ ~z ~o~c~s o~ ~r~s o~ (~r o~ mo~) rms CERTI~IYG CO~CTOR ~ND ~X PER rile PROaECT ~ND/OR DESIGN EYGINEER8 CERTIFIED ~CO~ D~WlNGS OF THIS ~ AS DESCRIBED BY N~E SHO~ AS OF THIS DA~ // P~SO~L~ ~o~, swo~ ~o C~RTm~NO~ .. ~ / ~ ~ smscmmB~o~ m ~ms ~,,~ ~/ ~~ r /~~' ~~- , i g. ~, THO~C~ P~SDENT ~:f~;,~y"~vEa I FLOmDA ST~~ERORO~, I ;J co~. No. C0670403 ] June 21, 1999 Wilsp. nMiller New Directions In Planning, Design & Engineering Mr. Thomas Kuck, P.E. Project Plan Review Collier County Development Services Center 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: lslandWalk Phase Two Utility Dedication Engineer's Certification Dear Mr. Kuck: Please accept this letter as represenl~ition that in our professional judgment and to the best of our knowl~ge and belief the potable water distribution and sanitary sewer collection systems as listed below tbr lslandWalk Phase Two been completed in substantial accordance with the plans (WM FILE NO. D-0772-13) and specifications approved by Collier County Engineering Review Services. Furthermore, to the best of our knowledge and belief the subject water and sewer facilities have been constructed by the contractor within the public right-of-way and/or dedicated easements. Please contact me should you have any questions regarding this matter. Sincerely, WILSONMILLER, INC. F. Allen Witt, P.E. Project Manager Engineer's signature and seal Naples Fort Myers Sarasota Bradenton Tampa 3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 www. wil$onmiller, corn June 15, 1999 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 34112 WATER DISTRIBUTION SYSTEM ISLAND WALK PHASE 2 A PART OF SECTION 33 TOWNSHIP 48 SOUTH, RANGE 26 EAST COLLIER COUNTY, FLORIDA Commissioners: This letter is to certify the completion of the WATER DISTRIBUTION SYSTEM located within the above referenced property. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier County Board of Commissioners. Sincerely, President TPM/cvk 73 COMMERCIAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891 June 15, 1999 Board of Collier County Commissioners 3301 Tamiami Trail East Naples, FL. 34112 SEWER DISTRIBUTION SYSTEM ISLAND WALK PHASE 2 A PART OF SECTION 33 TOWNSHIP 48 SOUTH, RANGE 26 EAST COLLIER COUNTY, FLORIDA Commissioners: This letter is to certify the completion of the SEWER DISTRIBUTION SYSTEM located within the above referenced property. Florida State Underground, Inc. furnishes at least a one (1) year guarantee of material and workmanship on the system, upon acceptance by the Collier County Board of Commissioners. Sincerely, .// TPM/cvk 73 COMMERCIAL BOULEVARD · NAPLES, FLORIDA 34104 · 643-6449 · FAX: 643-6891 Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number Date Post Date Payment Slip Nbr 140006 7/14/99 8:26:58 AM 7/14/99 UT 55808 ISLAND WALK DEV CO 5855 COVE CIR DOR452 WO#21400 Payor · SUNCO Fee Information Fee Code Description 42CYIN COUNTY INVOICES GL Account 40800000011510000000 Total Amount Waived $122.29 $122.29 , Payment Code Account/Check Number 2293 Payments Amount ~ CHECK Memo: ISLAND WALK DEV CO 4500 PGA BLVD #400 PALM BCH GARDENS FL 33418 Total Cash Total Non-Cash Total Paid $122.29 $0.oo $122.29 $122.29 Cashier/location: SWEET H / 1 User: EMERSON K Collier County Board of County Commissioners CD-P/us for Windows 95/NT Printed:7/14/998:27:23AM Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number I Date Post Date Payment Slip Nbr 46225 ; 8/13/99 8:13:57 AM 8/13/99 UT 57534 ISLAND WALK PH II FULL BORE FLUSH DIS POST WO 18450/18904/19028 Payor' FL STATE UNDERGROUND Fee Information Fee Code Description GL Account Amount Waived 42CYIN COUNTY INVOICES 40800000011510000000 $611.01 Total $611.01 Payments Payment Code Account/Check Number i Amount CHECK 21992 i $611.01 Memo: FLORIDA STATE UNDERGROUND Total Cash Total Non-Cash Total Paid $0.00 $611.01 $611.01 Cashier/location: FROLOFF E / 1 User: MURNANE G Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:9/13/99 9:34:41 AM GOLDEN GATE FIRE CONTROL & RESCUE DISTRICT 4741 GOLDEN GATE PARKWAY · NAPLES, FLORIDA 34116-6901 (941) 455-2121 · FAX (941) 455-7917 August 9, 1999 Sunco Building Corporation 6005 Vanderbilt Beach Road Extension Naples, Florida 34119 Gentlemen: Subject; Hydrant Flow Tests - Island Walk On August 4, 1999 the Golden Gate Fire Control & Rescue District performed a flow test on (13) hydrants located in the Island Walk project. The results are: Hydrant 33482633 - Guadeloupe Way 78 Static PSI 52 Residual PSI 55 Pitot Flow PSI 1919 GPM at 20 PSI Residual Hydrant 33482634 - Guadeloupe Way 76 Static PSI 52 Residual PSI 52 Pitot Flow PSI 1912 GPM at 20 PSI Residual Hydrant 33482635 - Guadeloupe Way 76 Static PSI 52 Residual PSI 52 Pitot Flow PSI 1912 GPM at 20 PSI Residual Sunco Building Corporation Page 2 August 9, 1999 Hydrant 33482636 - Guadeloupe Way & Island Walk Circle 70 Static PSI 60 Residual PSI 54 Pitot Flow PSI 2940 GPM at 20 PSI Residual Hydrant 33482637 - Hawkesbury_ Way 74 Static PSI 52 Residual PSI 50 Pitot Flow PSI 1926 GPM at 20 PSI Residual Hydrant 33482638 - Hawkesbury Way 74 Static PSI 46 Residual PSI 44 Pitot Flow PSI 1587 GPM at 20 PSI Residual Hydrant 33482639 - Hawkesbury Way 74 Static PSI 44 Residual PSI 42 Pitot Flow PSI 1493 GPM at 20 PSI Residual Hydrant 33482640 - Hawkesbury Way 74 Static PSI 44 Residual PSI 38 Pitot Flow PSI 1420 GPM at 20 PSI Residual Sunco Building Corporation Page 3 August 9, 1999 Hydrant 33482641 - Hawke~bury Way & N. Island Walk Circle 78 Static PSI 58 Residual PSI 36 Pitot Flow PSI 1789 GPM at 20 PSI Residual Hydrant 33482642 - Inagua Way 78 Static PSI 50 Residual PSI 36 Pitot Flow PSI 1492 GPM at 20 PSI Residual Hydrant 33482643 - Inagua Way 78 Static PSI 42 Residual PSI 40 Pitot Flow PSI 1373 GPM at 20 PSI Residual Hydrant 33482644 - Inagua Way 78 Static PSI 42 Residual PSI 36 Pitot Flow PSI 1303 GPM at 20 PSI Residual Hydrant 33482645 - Inagoa Way & N. Island Walk Circle 76 Static PSI 40 Residual PSI 52 Pitot Flow PSI 1536 GPM at 20 PSI Residual Sunco Building Corporation Page 4 August 9, 1999 Before completion of the project, the hydrants need to be painted OSHA safety yellow. The caps on hydrants #33482633, #33482634, #33482635, #33482636, #33482637, #33482638, #33482641, and #33482645 need to be painted OSHA safety light blue. The caps on hydrants #33482639, #33482640, #33482642, #33482643, and #33482644 need to be painted OSHA safety green. Also, blue road reflectors need to be installed to show location of all hydrants. This Fire District does not accept ownership nor does it maintain fire hydrants after their installation. Total due the Golden Gate Fire Control District for the thirteen (13) flow tests is $155.00. Sincerely, Donald R. Peterson Fire Chief DRP/pm Enclosures Golden Gate Fire Department Hydrant Flow Tests by Hydrant Number Hydrant Number greater than or equal to "33482633" and Hydrant Number less than or equal to "33482645" 33482633 HYD #1 GUADELOUPE WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi (~10 psi ~ 0 psi 08/04/1999 78 52 55 0 1244 1919 2091 2251 18 Brightj Jason C/F refighter Emt Subtotal Tests: 1 Max: 1244 1919 2091 2251 Min: 1244 1919 2091 2251 Avg: 1244 1919 2091 2251 33482634 HYD #2 GUADELOUPE WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi @10 psi ~ 0 psi 08/04/1999 76 52 52 0 1210 1912 2089 2255 18 Bright, Jason C/Firefighter Emt Subtotal Tests: 1 Max: 1210 1912 2089 2255 Min: 1210 1912 2089 2255 Avg: 1210 1912 2089 2255 33482635 HYD #3 GUADELOUPE WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM (~20 psi (~10 psi ~ 0 psi. 08/04/1999 76 52 52 0 1210 1912 2089 2255 ! 8_ ...... Br ght,~ Jason C/F refighter Emt ......................... Subtotal Tests: 1 Max: 1210 1912 2089 2255 Min: 1210 1912 2089 2255 Avg: 1210 1912 2089 2255 33482636 GUADELOUPE WAY & ISLAND WALK CIR KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM (~20 psi (~10 psi ~ 0 psi. 08/04/1999 70 60 54 0 1233 2940 3245 3526 18 Bright, Jason C/Firefighter Emt 08/04/1999 14:15 Page Golden Gate Fire Department Subtotal Tests: I Hydrant Flow Tests by Hydrant Number Hydrant Number greater than or equal to "33482633" and Hydrant Number less than or equal to "33482645" Max: 1233 2940 3245 3526 M in: 1233 2940 3245 3526 Avg: 1233 2940 3245 3526 33482637 HYD #1 HAWKESBURY WAY KENNEDY Date/Staff Static Resid Pitot Pitot2 GPM ~20 psi {~10 psi ~0 psi. 08/04/1999 74 52 50 0 1186 1926 2111 2283 ~ ............. BdghL ~a_s~ ~_r_e_ figh~r~m~_ ................................................................. Subtotal Tests: 1 Max: 1186 1926 2111 2283 Min: 1186 1926 2111 2283 Avg: 1186 1926 2111 2283 33482638 HYD #2 HAWKESBURY WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi ~10 psi ~ 0 psi. 08/04/1999 74 46 44 0 1113 1587 1739 1881 18 .............. Brightj Ja_s_o__n_C/Eim_figb_te__r_Emt Subtotal Tests: I Max: 1113 1587 1739 1881 Min: 1113 1587 1739 1881 Avg: 1113 1587 1739 1881 33482639 HYD #3 HAWKESBURY WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi ~10 psi ~ 0 psi. 08/04/1999 74 44 42 0 1087 1493 1637 1770 18 Br.ight, Jason C/Firefigbter_Em_t 08/04/1999 14:15 Page Golden Gate Fire Department Subtotal Tests: I Hydrant Flow Tests by Hydrant Number Hydrant Number greater than or equal to "33482633" and Hydrant Number less than or equal to "33482645" Max: 1087 1493 1637 1770 Min: 1087 1493 1637 1770 Avg: 1087 1493 1637 1770 33482640 HYD #4 HAWKESBURY WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM (~20 psi ~10 psi {~ 0 psi. 08/04/1999 74 44 38 0 1034 1420 1557 1684 _1_8 ................ _B_ _r_i g h_tj_ .J_ a_s_ _o_ n. 4 _C_/_F_i_r~f!gb_t_e _r _ ~ _m_ _t ............................................................................ Subtotal Tests: 1 Max: 1034 1420 1557 1684 M in: 1034 1420 1557 1684 Avg: 1034 1420 1557 1684 33482641 HAWKESBURY WAY & N ISLAND WALK CIR KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi ~10 psi ~ 0 psi. 08/04/1999 78 58 36 0 1007 1789 1950 2100 _1__8 ............. Bdgh_tj_ _Jas_o__n _ _c_/_F_i_r_e_f!gh~t.e _r, _Emt ....................................................................... Subtotal Tests: 1 Max: 1007 1789 1950 2100 Min: 1007 1789 1950 2100 Avg: 1007 1789 1950 2100 33482642 HYD #1 INAGUA WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM (~20 psi ~10 psi (~ 0 psi. 08/04/1999 78 50 36 0 1007 1492 1626 1751 .18 .... Bd ght,_ J as_o_ _n_ _C/Fi?_efighte_r_ E mt 08/04/1999 14:16 Page Subtotal Tests: 1 Golden Gate Fire Department Hydrant Flow Tests by Hydrant Number Hydrant Number greater than or equal to "33482633" and Hydrant Number less than or equal to "33482645" Max: 1007 1492 1626 1751 Min: 1007 1492 1626 1751 Avg: 1007 1492 1626 1751 33482643 HYD #2 INAGUA WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi (~10 psi @ 0 psi 08/04/1999 78 42 40 0 1061 1373 1496 1611 1__8_ ................. _B_rjg _h_t~_ _J.a_s_ o_n_ _ _c_/_F_i r_efigb_t_e _r_ E re_t_ .............................................................................. Subtotal Tests: 1 Max: 1061 1373 1496 1611 Min: 1061 1373 1496 1611 Avg: 1061 1373 1496 1611 33482644 HYD #3 INAGUA WAY KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi ~10 psi ~ 0 psi. 08/04/1999 78 42 36 0 1007 1303 1420 1529 1 _8_ .................. .Bd g htr_ _J_a_so_ _n _ _c_/.F_ire_ figb_t_e _r_ E m__t_ ............................................................................. Subtotal Tests: I Max: 1007 1303 1420 1529 Min: 1007 1303 1420 1529 Avg: 1007 1303 1420 1529 33482645 INAGUA WAY & N ISLAND WALK CIR KENNEDY Date/Staff Static Resid Pitot Pitot 2 GPM ~20 psi (~10 psi ~ 0 psi. 08/04/1999 76 40 52 0 1210 1536 1679 1811 _1.8 ............. B_dg hr_,_ Jaso_ _n C_!Firefighter Emt ................................... 08/0411999 14:16 Page z Golden Gate Fire Department Subtotal Tests: 1 Hydrant Flow Tests by Hydrant Number Hydrant Number greater than or equal to "33482633" and Hydrant Number less than or equal to "33482645" Max: 1210 1536 1679 1811 Min: 1210 1536 1679 1811 Avg: 1210 1536 1679 1811 Total Flow Tests: 13 08/04/1999 14:16 Page Zl SANITARY SEWER SYSTEM INFILTRATION REPORT DATE: CRITERIA: *50 gallons per inch of internal pipe diameter per mile per day including manholes or as required by the specifications. An infiltration and/or inflow observation was made on the subject project. The results are as follows: . *Gal /t~7~~ LF x ~__ in. Dis x 50 Da}, 5280 LF in. Dia MI x 1 gal 24 hr x 60 gal. = ~T~-,~ min day min From To Gallons per Minute Measured Gallons per Minute Allowable ~X MH~ t~q MH~ ~ .... '~ -/ii'?~;~ GPM ~" ~r3© GPM ,w, .-c'. Prepared by:~~/~., Revised 1/86 G1 SANITARY SEWER SYSTEM INFILTRATION REPORT PROJECT: DATE: CRITERIA: *50 gallons per inch of internal pipe diameter. per mile per day including manholes or as required by the specifications. An infiltration and/or inflow observation was made on the subject project. The results are as follows: *Gal ~.~LF x ~ in. Dis x 50 Day 5280 LF in. Dia MI x 1 24 hr x 60 gal. = day min From To Gallons per Minute Measured GPM Gallons per Minute Allowable Prepared by:~~ / Revised 1/86 G1 FROM : FLORIDA STATE UNDERGROUND INC. PHONE NO. : 941 643 6891 Jul. 1999 12:05PM P2 t+uctu e Rekabilitation! II II I I . ~ I I I I I IIII I II COLLIER COmiTY UTILiTiES W~STEW~TER DEPARTMENT PROJECT VIDEO REVIEW DATE OF REVIEW: 5-20-99 PROJECT NAME: Island Walk, Phase II (North) ENGINEER OF RECORD." CONSTRUCTION CONTRACTOR: VIDEO CONTRACTOR: Sewer Viewer COMMENTS: Lines and services acceptable. RECOMMENDATIONS: ~ ACCEPTABLE: ~--~ REVIEW NUMBERED COMMENTS IN ONE YEAR: [__]NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) ~--~ OTHER RECOMMENDATIONS: RECEIVED MAY 2 1 1999 WASTEWATER DEPARTMENi' COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 August 5, 1999 Mr. Allen Witt Wilson, Miller, Barton & Peek, Inc. 3200 Bailey Lane, Suite 200 Naples, Florida 34105 RE: Island Walk Phase 2, Water Dear Mr. Weeks: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on August 5, 1999. Conditions were found to be acceptable, and appear to meet County standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418 or Clyde Fugate at (941) 403-2417. Sincerely, Engineering Inspections Supervisor CF/taa/f:\Inspection form water & sewer cci Cindy Erb, Engineering Technician, Public Works Joe Cheathan, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section File Phone (941) 403-2400 Fax (941) 643-6968 www.co, collier.fl.us