Pelican Lakes RV Resort Unit 1MEMORANDUM DATE: TO: FROM: January 16, 1998 Maureen Kenyon, Supervisor, Clerk to Board Shirley Nix, Engineering Technician II.~_,~-~ Project Plan Review RE: Pelican Lakes, RV Resort, Unit One Water Facilities Acceptance On ,~f~/ , 199~_~, The Board of County Commissioners granted final acceptance of the water facilities within the above-referenced project. Attached, please find the following recorded documents, in order: 1. Bill of Sale 2. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. o o o 10. 11. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letters from Engineering Review Certification of pressure testing of water lines by Engineer of Record Certification of pressure testing of sewer lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities DER Placement-in-Service letter for sewer facilities Contractor's Final Release of Lien Lab results on bacteriological test for water lines Memorandum to Maureen Kenyon, Supervisor, Clerk to Board January 16, 1998 Page Two 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. Certification concerning contributions-in-aid of any construction Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division Letter from fire district regarding ownership and maintenance of fire hydrants Certification of field fire flow capacity testing by Engineer of Record Copy of backflow prevention assembly test report Certification of the inflow/infiltration test for the sewer lines by Engineer of Record Electrical Contractor's certification on Pump Station electric service wire sizing and voltage drop, pursuant to National Electrical Code specification Copy of pump station start-up report Copy of video tape test report Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations Memorandum to Maureen Kenyon, Supervisor, Clerk to Board January 16, 1998 Page Three 25. One copy of the recorded plat 26. One set of record drawings, signed and sealed by the Engineer of Record If you have any questions, please call and advise accordingly. /sn attachments doc:2094-2 ~J ~- uO0~O -, ,, Orr Z 0 2266519 OR: 2378 PG: 0840 RECORDED in 0~IClAL RECORDS of COLLIER COUN?¥, ~n 01/08/98 at ll:27AM DWIGHT E. BROCK, CLERK Instrument Prepared By: Dennis P. Cronin, Esquire Retn: BOND, SCHOENECK & KING, P.A. ENGINEERING REVIEW SERVICES 1167 Third Street South Naples, Florida 33940 SHIRLEY NIX EX? 5586 UTILITY FACILITIES WARRANTY DEED THIS INDENTURE made this 7~ day of /7~J , 1997, by PELICAN LAKE, INC., a Maryland corporation, on behalf of itself and as general partner of Pelican Lake Limited Partnership, a Maryland Limited Partnership (hereinafter referred to as "Grantor") and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Grantee"). REC ~EE 19.50 DOC-.70 .70 COPIES 4.00 WITNESSETH: That said Grantor, for and in consideration of the sum of Ten and 00/100 Dollars ($10.00) and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, the master water meter lying within the follow- ing described land, together with appurtenant easement rights for the operation, installation and maintenance of said master water 0030127.01 5/6/97 OR: 2378 PG: 0841 meter, situate, lying and being in Collier County, Florida, to wit: See attached composite Exhibit "A" which is incorporated herein by reference and said Grantor does hereby fully warrant the title to said master water meter, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the master water meter conveyed herein shall not be deemed to convey any of the lands described herein. Grantor and Grantee are used for singular or plural, as the context requires. IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. Witness Prin~ed Name Printed Name Pelican Lake Limited Partnership, a Maryland limited partnership by its duly authorized general partner, PELICAN LAKE, INC., a Mar~an~ corporation ~ -- . Wilder, President 0030127.01 5/6/97 OR: 2378 PG: 0842 STATE OF FLORIDA ) COUNTY OF COLLIER ) The foregoing instrument was sworn to and subscribed before me this ~2-~day of , 1997, by Norman W. Wilder, President of PELICAN INC., a Maryland corporation, on behalf of itself and as General Partner of Pelican Lake Limited Partnership. He is personally known to me. Notary Public Printed Name of Notary Public My Commission Expires: 0030127.01 5/6/97 *** OR: 2378 PG: 0843 *** EXHIBIT A All County utility easements indicated C.U.E. according to the~plat for Pelican Lake R.V. Resort, Unit One, as recorded in Plat Book ~ ?, pages ~ to ~, Public Records of Collier County, Florida. Document Prepared By: Dennis P. Cronin, Esquire BOND, SCHOENECK & KING, P.A. 1167 Third Street South Naples, Florida 33940 2266520 OR: 2378 PG: 0844 RECORDED in OPPICIAL R~CORDS of COLLIER COUNTY, FL Ol/OS/98 at lI:27AM DWIGHT E. BROCK, CLERK Retn: ENGINEERING REVIE# SERVICES SHIRLEY MIX ~X? 5586 COPIES 19.50 4.00 BILL OF SALE THIS BILL OF SALE evidencing the sale and conveyance of the master water meter described herein is made this 7~ day of /'7~/ , 1997, by PELICAN LAKE, INC., a Maryland corporation, on behalf of itself and as general partner of Pelican Lake Limited Partnership, a Maryland Limited Partnership (hereinafter referred to as "Seller") and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). WITNESSETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, that certain master water meter lying within the following 0030134.01 5/6/97 OR: 2378 PG: 0845 described land, together with appurtenant easement rights for the operation, installation and maintenance of said master water meter, situate, lying and being in Collier County, Florida, to wit: See attached composite Exhibit "A" which is incorporated herein by reference. The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used singular or plural, as the context requires. 0030134.01 5/6/97 OR: 2378 PG: 0846 IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. Witness Prin~ed Name ~i~ness ~ -- Printed Name Pelican Lake Limited Partnership, Inc., a Maryland limited partnership by its duly authorized general partner, PELICAN LAKE, INC., a Maryland corporation W. Wilder, President STATE OF FLORIDA ) COUNTY OF COLLIER ) The foregoing instrument was sworn to and subscribed before me this ~ ~ day of /'7,aa~ ,1997, by Norman W. Wilder, President of PELICAN LAKE, INC., a Maryland corporation, on behalf of itself and as general partner of Pelican Lake Limited Partnership, a Maryland limited partnership. He is personally known to me. Notary Public My commission expires: 0030134.01 5/6/97 *** OR: 2378 PG: 0847 *** EXIFIRIT A All County utility easements indicated C.U.E. according to the plat for Pelican Lake R.V. Resort, Unit One, as recorded in Plat Book ~ 7, pages 72. to ~.~ , Public Records of Collier County, Florida. OWNER'S AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLIER On this ~ day of /7~ ~ 1997 before me ~ ' personally appeared NORMAN W. WILDER, President of PELICAN LAKE INC., a Maryland Corporation, on behalf of itself and as general partner of Pelican Lake Limited Partnership, a Maryland Limited Partnership, owner of property, to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and speci- fications, or extra items, used in the construction or repair of the master water meter on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant further says that the master water meter described herein is unencumbered. 1 0030135.01 Affiant, further says that the master water meter described herein is not included in, encumbered by or subject to a Uniform Commercial Code financing statement. Affiant, as and on behalf of the owner of the subject master water meter, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject master water meter. Affiant is used as singular or plural, as the context requires. The master water meter referred to herein are located within the real property described in the attached Exhibit "A". Witness Prin~ed Name ~tness U ~ Printed Name of Witness Pelican Lake Limited Partnership, a Maryland limited partnership by its duly authorized general partner, PELICAN LAKE, INC., a Maryland corporation By: /~'0~man W~~. ~i l~de r, President 2 0030135.01 STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was sworn to and subscribed before me this ~ ~- day of ~7,~. WILDER, President of PELICAN LAKE, , 1997, by NORMAN W. INC., a Maryland corporation, on behalf of itself and as general partner of PELICAN LAKE LIMITED PARTNERSHIP, a Maryland limited partnership. He is personally known to me. Notary Public My Commission Expires: Document Prepared By: Dennis P. Cronin, Esquire BOND, SCHOENECK & KING, P.A. 1167 Third Street South Naples, Florida 34102 (941) 262-6812 3 0030135.01 ATTORNEY'S AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLIER ON THIS ~ day of personally appeared David N. rgto Se n, a licensed attorney , 1997, before me authorized to practice in the State of Florida, to me personally known, whose current business address and telephone number is c/o Bond, Schoeneck & King, P.A., 1167 Third Street South, Naples, Florida 34102, (941) 262-6812 (hereinafter "Affiant"), who, being duly sworn on his oath, does say: This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District to accept dedication and conveyance of the master water meter located within or upon the real property described in the attached Exhibit "A", which is incorporated herein by reference, said land being located in Collier County, Florida. 1. The Affiant has examined record title information to both the real and personal property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 2. The record owner of the master water meter described herein is Pelican Lake Limited Partnership (hereinafter "Owner"). The Owner acquired its regord interest by Deed recorded at Official Records Bookie, at Page ~LJ~l, of the Public Records of Collier County, Florida. 3. The subject real and personal property is not encumbered of record. 0030136.01 4. Affiant further states that the information contained in this Affidavit is true, correct and current as of the date the Affidavit is given. David N. Sexton STATE OF FLORIDA COUNTY OF COLLIER The fo[egoing instrument was me this 7~ day of ~ is personally known to me. sworn to and subscribed before , 1997, by David N. Sexton, who Publ Prq/nted Name: My Commission Expires: ~"'~'~=~>~/ OFFICIAL NOTARY SEAL ~ ('? ~('/~ KIMBERLY A SPINK ~," "~'~?~:~ ~ CC404472 .X.. ~'<~" ~ MY COMMISSION EXP. ~ ~' O~,. ~o' AUG ,, 3~1998 ,,, 0030136.01 * OR: 2254 PG: 219 ** !~-----'~--, ..... 5=--':---- - . -· --~'~,~ , ~, ~-, JOHNSON FORRF. S"r H. BAJ~KS Lirllr E. JOHNSON · ~osIr~H W. lrBNrR A~4 C)fl Z'~' D. DAN W. DICK[Y K~hFfON R. GEORG[ J. KALAL EXHIBIT "A" CIVIL ENGINEERS AND I. AJNID SUR'V~='YORS October 6, 1986 REVISED DESCR]PTION PARCEL ~, 109 ' THE PROPOSED REAL~GNF, Elfi' OF STATE ROAD 951 SECTZON 15, T. 5~, S., R. 26 E. .CGcL]ER COUNTY, FLOR]DA · .CO. NTAZNZNG 0.43 ACRES, HORE OR LESS. ~,11 that part of the South 1100 feet of the north half (N-1/2) of tile north half (N-1/2) of Section 15F ToWnship 51 South, Range 26 East, Collier County, Florida lying easterly of existing State Road S-951 (100 feet wide) being a par~el 17 feet wide (as mea- .sured on a perpendicular) with the wisterly line of said parcel being the easterly line of said right-of-way 100 feet wide, said westerly line lying 83 feet easterly free (as measured 'on. a per- pendtcular) and the' easterly line of said parcel lying 160 feet easterly from (as measured on a perpendicular) the following described centerltne of a proposed right-of-way for State Road 9S1 (200 feet wide): From the southwest corner, of Section 15, Township 51 South, Range 26 East, Collier County, Florida run S 88° S8' 22' E along the south line of the southwest quarter (SV-1/4) of satd Section 1S for 1138.93 feet to the centerline of construction of State Road 951 (200 feet wide) at Station 294+04.46 and the Point of Beginning. From said Point of Beginning run N 02e 28' 03' E, paral- .lel with and 33 feet westerly from the' centerltne of State Road S-9S1 (100 feet. wide) for 1S,4SZ.33 feet to Station 448+S6.7g at the centerltne of U.S.41 .(State Road 90) in the northwest quarter (NV-I/4) of Section 3, said township and range and the end of the herein de- scribed center11ne. Searings are Plane Coordinate for the Florida East Zone. · ~%1 Lilnd Surveyor Professtm Plorida Certif~lcate No. 2724 LEJ/ct 13956 Received $ _ , ~ 13ocurnefltary Stamp Tax --t I /% Class 'C- Intang;ble Retch/ed $ .~ersonal Property Tax COL~NTY CLERK QF ~_.::/'~q"S.. ~ / .~.~ COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT SERVICES DIVISION ENGINEERING REVIEW SECTION 2800 NORTH HORSESHOE DRIVE NAPLES, FL 55942 (941) 645-8400 .\ CERTIFIED BLUE CHIP COMMUNITY August 18, 1997 Mr. Kevin Leadbetter Wilson, Miller, Barton & Peek, Inc. 3200 Bailey Lane Naples, FL. 34105 Re: Pelican Lake RV Resort, Phase One Dear Kevin: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, John R. Houldsworth Senior Engineer CC: Subdivision File Shirley Nix Made this ~'~ WARRANTY DEED · · FOR CLERK'S USE day of November, 1996. BETWEEN GARY L. DANCA, as sole remaining Trustee of the WMBS&P Profit Sharing Plan and Trust, party of the first part, Grantor, whose post office address is 3200 Bailey Lane, Naples, FL 34105, and PELICAN LAKE LIMITED PARTNERSHIP, a Maryland limited partnership, party of second r G who post office address is 2330 W. Joppa Ro~d, Suite 210~ Luthervillet MD 21093 and whose Social Security Number/PEIN is WITNESSETH: That the said party of the first part for and in consideration of the sum of TEN DOLLARS AND NO/100, plus other good and valuable consideration, to it in hand paid by the said party of the second part, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said party of the second part, its successors and assigns forever, the following described land situate, lying and being in the County of Collier and the State of Florida, to-wit: The South 1,100 feet of the North 1/2 of the North 1/2 of Section 15, Township 51 South, Range 26 East, lying East of State Road No. 951, Collier County, Florida LESS AND EXCEPT a parcel comprising 0.43 acres, more or less, described in the "Revised Description Parcel No. 109" attached hereto as Exhibit "A" and made a part hereof by this reference, which parcel was conveyed to Collier County, a politial subdivision of the State of Florida by deed dated November 3, 1986 and recorded in O.R. Book 1233, Pages 799-801, Public Records of Collier County, Florida. Subject to easements, restrictions, reservations of record common to the subdivision and taxes for the current year and subsequent years. Property Appraisers Parcel Identification Number: 00742800005 And the said party of the first part does hereby fully warrant title to said land, and will defend the same against the lawful claims of all persons whomsoever except for taxes for 1996 and restrictions, reservations and easements of record. IN WITNESS WHEREOF, the said party of the first part has hereunto set its hand and seal the day and year above written. Signed, sealed and delivered in the presence of: Wisness ~ ~igna~cure . Print name ~}OOr-'~ Witness #2 Signature Print name ~ I rD~w~o~'=~ STATE OF FLORIDA COUNTY OF COLLIER Gary L. JDanca, Tr6stee 2122571 OR: 2254 PG: 2191 I~CORDRD In O~FICIAL I~CORDS of COLLIIR COUNT~, 11/26/96 a~ 12:24P~ D~IGH~ S, BROCK, ietn: BOMD $CHOIMBCK BT AL 1167 THIRD ST S #I07 NAPLIS FL 34102 7098 3000000.00 I~C Fll 10,50 DOC-,?0 21000,00 I HEREBY CERTIFY that on this day before me, an officer duly qualified to take acknowledgments, personally appeared Gary L. Danca, as sole remaining Trustee of the WMBS&P Profit Sharing Plan and Trust, to me known to be the person described in and who executed the foregoing instrument or who has produced as_,id~Q%ifi~atio~, an.d. wh~ e.c~nowled~e~ be~f-u~, m_e that he execu~ed3he same. WITNESS my hand anu o==~cia£ seal in =ne county and S.~a~'e £ast~f, ore~Q!d this/~~ day of November, 1996. t ~ / ' ~--~ , J ~Ngtar~y Signstur~ (SEAL) Print name /"~7";~()/~ ;~ ~_, ~dK6~;~F~F4 My Commission Expires: Preparation of Instrument Only Without Examination or Opinion of Title: James A. ~ilon, P.A. SIESK¥, PILON & WOOD 1000 N. T~iami Trail, Suit,~ 201 Naples, Florida 34102 EXPIRES: ,June 20, 2000 COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT SERVICES DIVISION ENGINEERING REVIEW SECTION August 20, 1997 2800 NORTH HORSESHOE DRIVE NAPLES. FL 55942 (941) 645-8400 A CERTIFIED BLUE CHIP COMMUNITY Stephen A. Means Wilson, Miller, Barton & Peek, Inc. 3200 Bailey Lane #200 Naples, FL 34105 Re: Pelican Lakes RV Resort, Unit One De. Mr. Means: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very tmly yours, Shirley Nix Engineering Technician II CC: Tim Clemons, Wastewater Director Michael Newman, Water Director Cindy Erb, Public Works Dory Nitch, Wilson, Miller, Barton & Peek, Inc. May 14, 1997 Mr. Thomas Kuck, P.E. Senior Project Manager Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: Pelican Lake R.V. Resort Unit One Utility Testing Results Dear Mr. Kuck: The following attached tests for the subject project are in our professional judgment and to the best of our knowledge and belief representative of actual field conditions on the date performed: 1. 8" watermain pressure test dated March 10, 1997 If you should have any questions, please do not hesitate to contact our office. Sincerely, WILSON, MILLER, BARTON & PEEK, INC. Step,eh A. Means, P.E. Encls. Norman Wilder, w/o enclosures Jan Stevens, w/o enclosures Dory Nitch, w/o enclosures Engineer's Signature and Seal WILSON, MII_LEP,, BAI*,TON t~. PEEK, IN(:. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 ' Ph 941-649-4040 Fx 941-643-5716 ~/cb Site: www.wilsonmillcr, com E-mail: naplcs~wilsonmillcr, com 5/1~97 - W~2370027.~8 WILSON · MILLER · BARTON.& PEEK, INC. HYDROSTATIC TEST REPORT iZ.SX/,5 /z. zs Project~h~.~a Type of Main Plan File supt. Date of'Test The computed allowable leakage for the test section is (calculations attached) ~'~, ! ~ Gal. Hr. The maintained test pressure for the test duration was psi. The measured leakage during the test was The duration of the test was .The measured leakage was Gal. Hr. The method of measurement was Meter Calibrated Drum K The hydrostatic test for this section meets~ ~.. does not meet the allowable leakage. WILSON, MILLER, BARTON & PEEK, INC. 'BYe../~ ~ ~:7~.. Date: · Fie/gl Representative 12/2/94-00110036.BKY June 1 O, 1997 Mr. Thomas Kuck, P.E. Senior Project Manager Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 Subject: Pelican Lake R. V. Resort Unit One Utility Testing Results Dear Mr. Kuck: The following attached tests for the subject project are in our professional judgment and to the best of our knowledge and belief representative of actual field conditions on the date performed: 1. 4" forcemain pressure test, dated 3/13/97 2. Inflow/infiltration test, dated 3/10/97 If you should have any questions, please do not hesitate to contact our office. Sincerely, WILSON, MILLER, BARTON & PEEK, INC. Stephen A. Means, P.E. Vice President Enclosures CCi Norm Wilder, P.L. Limited Partnership, w/o enclosures Jim Stevens, J.D., Ltd., w/o enclosures Kevin Leadbetter, WMB&P, Inc., w/o enclosures &~ 7~~/~_.~ Engineer's Signature and Seal 6/10/97 - W-02370058.DEN 237-3-cor WILSON, MILLER, BARTON & PEEK, INC. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 · Ph 941-649-4040 Fx 941-643-5716 Web Site: www. wilsonmitlcr.com E-mail: naples@wilsonmillcr, com WILSON · MILLER · BARTON & PEEK, INC. HYDROSTATIC TEST REPORT Project?t~ L~t~ Type of Main Plan File Supt. Date of Test 23 -/3'-q .'7 The computed allowable leakage for the test section is (calculations attached) t~, t:5 cfi Gal. Hr. The maintained test pressure for the test duration was psi. The measured leakage during the test was Gal. The duration of the test was Hrs. The measured leakage was Gal. Hr. The method of measurement was Meter Calibrated Drum The hydrostatic test for this section meets ~<' does not meet the allowable leakage. WILSON, MILLER, BARTON & PEEK, INC. Fiel~ Representative' 1212194430110036.BKY nmental protectionl. 2295 Victoria Aver~, Suite )64 Fort Myers. Flodda ~3~t-3~1 june 17, 1997 Stephen A. !(eans, P..E. Wilson, Miller, Bart:eh & ~'eek, !nc. 3~00 Bailey Lane, Suite 200 Naples, Florida 3~105 JUN 18 1997 Virginia B, Wetherel[ Secretary Pelican Lake Resort R.V. Resort Unit One (Collier County Regional WTP) DS l~L-300019 Dear M~. Mez~ns: This acknowledges receipt~ of certification that the subject water distriba~icn ~.y_=~:em e~-tensi, on has baen completed in accordance with tha p!an~ and re!at~d ma'terials permitted ~y this agency under '~*'~*- NL;~ber m<- lC~ February- C 1997 .... ll-~)nO dated , Based or, this '""~' ce,].~l~lcati, en and zatisfactory bacteric, logical ,;..[~_.[~1~33,: tho~ facilities fox' service Your continence, ccs'pe,.u<x~-~on In o~-'water supply program IS appreciated Sinceroly, Gary~A. , Ma i er Pr~_,~esszon~l En~.n~er ~II GAM/LP'L t skw cc: NDrman Wilder Michael Ne~wman Department of Environmental Protection Lawton Chiles Governor South District 2295 Victoria AYenue, Suite 3,4 ~'C~'/~t:~e cB;eW~ ~h e r e,, Fort ~yers, Florida 33901-3881 JUL 2 I 1997 ~ ~ WA ST~WAT[ July 21, :~ ..... .:,,-.:. ' · R~ Norman Wilder, President Pelican Lake Limited Partnership 2230 West Joppa Road, suite 210 Lutherville, MD 21093 Re: Collier County - DW/CS Pelican Lake R.V. Resort-Unit One Collier County/South WWTP CSll-300022 Dear Mr. Wilder: We have received a certificate of completion of construction, dated July 8, 1997, as submitted by Stephen A. Means, P.E. of Wilson, Miller, Barton and Peek, Inc. for the project authorized by the above permit number. Accordingly, the sewer collection system may be placed into service. HWY/SK cc: Stephen A. Means, P.E. Timothy L. Clemons Sincerely, ~arley/~W. YoD6g, Ph.D., Water Facilities Section Manager P.E. "Protect, Conserve and Manage Florida's Environment and Natural Resources" Printed on recycled paper. 6115 Idlewild Street, S.E. Fort Myers, Florida 33912 Phone: Fax# : 941.275-1166 941-275-8874 FINAL RELEASE OF LIEN KNOW ALL MEN BY THESE PRESENTS: That the undersigned, for and in consideration of the payment of the sum of Twenty- three Thousand, Three Hundred and No/100 Dollars ($ 23,300.00) paid by Bonness, Inc., receipt of which is hereby acknowledged, hereby releases and quit claims to the said Bonness, Inc., its successors and assigns, and pelican Lake Limited Partnership, the owner, all liens, lien rights, claims or demands of any kind whatsoever, which the undersigned now has or might have against the building on premises legally described a$~ "Pelican Lake R.V. Resort, Unit One", a part of Section 15, Township 51 South, Range 26 East, Collier County, Florida. on account of labor performed and/or material furnished for the construction of any improvements thereon. That all labor and materials used by the undersigned in the erection of said improvements have been fully paid for. IN WITNESS WHEREOF, I have hereunto set my hand seal this 30th day of April, 1997. WITNESSES: STATE OF FLORIDA COUNTY OF LEE correct. personally known to me. My commission expires: ~¢,~ ,%~ SALLY M, ROONEY ~ ~"'~ COM,,~,~,>',.,' '°~'"~1 ,, '~'~ 411367 'eO[ ~L~ ATLANTIC BONDING CO., [ hereby acknowledge that the statements ~e foregoing ~ease of Lie[ are true and Sworn to and subscribed before me this 30 day of April, 1997 by [~obert D. Meadows, who is COIJIER COUNTY GOVERNMENT PUBLIC WORKS DIVISION 3301 E. TAMIAMI TRAIL NAPLES, FL 34112 (941) 732-2575 FAX (941) 732-2526 July I 1, 1997 A CERTIFIED BLUE CHIP COMMUNITY RDMC 6115 Idlewilde St. S.E. Ft. Myers, Florida 33912 Bacteriological Analysis Results - Main Clearance Attached please find the analytical results on the following water main clearance project: Pelican Lake R.V. Resort. These results were found to be acceptable by Collier County Laboratory, # 55261. Should you have any further questions regarding this matter, please feel free to contact me at (941) 352-7004. Sincerely, Mary Jan~ Havener Laborato~ Supe~isor State of FLorida Department of Health and Rehabilitative Services Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WA TER BACTERIOLOGICAL ANALYSIS DHRS# 55261FORLABUSEONLY Rec'd 10:45 am TESTED Date: 7-- 9-97 By: HLB/HJH Tlme: 2:35 pm TO 3:30 pm CONFIRHED Press hard, (5) copies SYSTEM NAME: __¢:r',l 1 i ~.r ~nlJnt_y Mater DeptSYSTEM I.D. NO: 51~.4069 SYSTEM PHONE #: 732-2558 ADDRESS: 3301 TamiamJ, T¥ a i 1 , Nap],e$, F'I COUNTY: Coll ~,e¥ __ DISTRICT: ] 1 COLLECTOR: __M! R/M.I'FI SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: ..... 7-' '~" ¢~'? ~,~: !~.;E; _ lc) __9: 59 am TYPE OF SUPPLY(Circle one): o~unity water system '~ oncommunity water system Nontransient - noncommunity water system Private well sw~n~m~ng pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement (Check Box) [ ] Distribution [ ] Raw TO BE COMPLETED BY COLLECTOR OF SAMPLE COLL. SAMPLE POINT NO. (Specific Address) r') ~ 9 0~25 * Results in this column are presumptive. P - Coliforms are present A - Coliforms are absent COLLECTOR PHONE #: .~;,;-" ,'~)k:,/ Well survey Other [ ] Check here if payment made to county public health unit TO BE COMPLETED BY LAB ANALYSIS METHOD: ~'M, MF~ --~TF MMO-MUG PA NON CONFIRM CONFIRM COLIFORM *TOTAL TOTAL FECAL E. COLI SAMPLE NUMBER 1')() / '9;7 191- 7' 97 Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES State of Florida Department of Health and Rehabilitative Services Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS )HRS~ 5526~ FOR LAB USE ONLY ec'd ll:06am 7-- 8-,97 TESTED Date: 7- 8-97 8yMLB/MJ[t Time: 1:10 pm TO 2:19 pm CONFIRMED Press hard, (5) copies SYSTEM NAME: O. nl ] ]~:~ ¢'~(>tJnt'y I~Rt~¥ 3301 Tamiami Trail, Naple~:;, ADDRESS: SYSTEM I.D. NO~] 14069 Fl Collier COUNTY: COLLECTOR: ~1 R/M.-[H SAMPLE SITE (Locality or Subdivision): tAKE R.V. RESORT SYSTEM PHONE #:732-2558 ]1 DISTRICT: COLLECTOR PHONE #: _ 352-~ DATE AND TIME COLLECTED: 7- ~--g7 I 0:0(') i'.¢) I 0:0~ Am TYPE OF SUPPLY(Circle one): ~ommvnity water syste~Noncommunity water system Nontransient ~ noncommunity water system P~vate well s~immi'ng pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement clea[an_~c~, Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB ANALYSI METHOD: ~ MTF MMO-MUG PA COLL. SAMPLE POINT NON CONFIRM CONFIRM NO. (Specific Address) COLIFORM *TOTAL TOTAL FECAL E. COL~ SAMPLE NUMBER 8 0 ~-00 /¢ 148-7-97 Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. * Results in this column are presumptive. P - CoLiforms are present A - CoLiforms are absent C - Confluent growth TA - Turbid, Absence of gas or acid TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): 000 NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES pelican RESORT April 25, 1997 Collier County Board of Commissioners Government Complex 3301 East Tamiami Trail Naples, FL 34112 Subject: Pelican Lake RV Resort Utility Facilities Dedication Dear Sir: This letter will certify that Pelican Lake Limited Partnership, the developers of Pelican Lake RV Resort, has received no contribution in aid for the construction of the subject property. Sincerely, No~~an Wi1 de~/r~---~- President Pelican Lake RV Resort NW/ps 5775 22nd Avenue S.W., Naples, Florida 34116 · 1-800-835-4389 or 941/352-9588 CONTRACTOR'S CERTIFIED LIST OF INSTALLED MATERIALS AND COSTS SYSTEM NAME: Pelican Lake RV Resort, Unit 1 (per regulatory agency permit name) OF (date) THIS IS A: X WATER SYSTEM SEWER SYSTEM Material List Instruction Please list each and/or all materials separately by item or material description, sizes, etc. Then show quantity installed, unit cost installed and total cost installed. Please specify lump total costs for service, fire meter vaults, pumping stations, etc. with quantity. However, with full description, sizes, etc. Item Description Size Quantity Unit Unit Cost Hot tap with tapping sleeve, valve and box 12x8 1 EA $ 2,800.00 $ Master meter assembly 6x3 1 EA $ 20,50Q00 $ Total 2,800.00 20,500.00 GRAND TOTAL $ 23,30000 (If this space is not large enough, then continue with added exhibits or sheets, however, with proper page numbers shown at bottom of sheet, with system name complete on each page.) I do herby certify the above described list of materials, quantities of materials, kinds of materials, including installation and all costs as installed, to be complete, true and accurate as per the final pay estimate and/or all invoices or statement of (by or from) this certifying contractor and as the project and/or design engineers certified record drawings of this system (water and/or sewer) as described by name shown as of this date. Sworn to and subscribed befoe methis 30th day of April , 1997. (_~Notar~ t~blic) (~ ¢.'~ ~,_ SALLY M. ROONEY ~ ~ ~ COMM~SC',O~ ¢ CC 411367 "~F ~%~ ATLANTIC BOND,NG CO., INC. I~o~¥~rt D. Meladows, lresident - Of: RDMC, Inc. 6115 Idlewild Street, S.E. 4/30/97 (Date) Ft. Myers, Florida 33912 (Affix corporate seal here) Page 1 of 1 May 14, 1997 Mr. Thomas Kuck, P.E. Senior Project Manager Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: Pelican Lake R.V. Resort Unit One Utility Dedication Engineer's Certification Dear Mr. Kuck: Please accept this letter as representation that in our professional judgment and to the best of our knowledge and belief the potable water distribution and sanitary sewer collection systems for the project have been completed in substantial accordance with the enclosed plans, WMB&P, Inc. Drawing File No. D-1332 and specifications approved by Collier County Project Plan Review Services. Furthermore, to the best of our knowledge and belief the subject water facility has been constructed by the contractor within the public right-of-way and/or dedicated easements. Please contact this office should you have any questions regarding this matter. Sincerely, WILSON, MII.LER, BARTON & PEEK, INC. Stephen A. Means, P.E. Encls. CC: Norman Wilder, w/o enclosures Jun Stevens, w/o enclosures Dory Nitch, w/o enclosures Engineer's Signature and Seal WIESON, MiLLEtS,, BARTON & PEEK, IN(:. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 - Pix 941-649-4040 Fx 941-643-5716 Web Kite: www. wilsonmil[er.ct~ln E-mnil: naplcs~wilsonmillc~r, com 5/1~97 - W4237~6.~ N0237~3-~-EDED .%', ~/,k', I:~ ,~'t ,~ 1 ~'~ ~; ~ ~,t: ~ [ i,, ~, l~'~, ,~ 6115 Idlewild Street, S.E. Fort Myers, Florida 33912 Phone: 941-275-1166 Fax#: 941.275.8874 WARRANTY The undersigned, RDMC, Inc., does hereby warranty and/or guarantee the water and sewer facilities of the following to be free from defects of material and workmanship for a period of at least one year from the date of acceptance of Collier County Utility: "Pelican Lake R.V. Resort Unit One", a part of Section 15, Township 51 South, Range 26 East, Collier County, Florida. The undersigned party further agrees that they will at their own expense, repair and replace all such defective work and all other work damaged by said defective work under this warranty-guarantee. It is further understood, that the consideration for the giving of this warranty and/or guarantee is required by the general conditions and specifications under which this contract was let. DATE: April 30, 1997 RDMC, Inc. sident STATE OF FLORIDA COUNTY OF LEE Sworn to and subscribed to before me this 30th day of April Robert D. Meadows who is personally known to me. ,1996, No;tory Ptl~ic Sally M. Rooney My Commission Expires: -,' ,C(~llier C~unty Board of County Commissioners KYLE OON~TIRUCTION Payments · Totll N~.C. akh ,. ~H_£0K_ "-.t ~t 194,1TM .... ?_:_ FULL BORE FLUSH, CHLOIA, & POST CHI. OR ~ WO g,~2 Ute¢, MURNANE_O ~UG--19--9? 09:5~ ~m .~IM STEVENS DATE: 7124197 PAGE TO: FROM; lIEF': UTIt. ITtE.$ DIVISION, SITE PLAN REVI~-W EAST NAPLES FIR~ DEPARTMENT FIRE HYDRANT OWNERSHIP AND MAINTENANCE The East Naples Fire Control an~J Rescue District ~grees to aCCel)L ownership and maint, enance of the hydrant(s) IocateO Pelican Lake ph t (6 hydrants) This ownership and maintcn,~nce agreement shalt not in any wa), be construed to altev;ate the owners, developer~, contractors etc.., from any liabil~tiy for dam~.~9es that may occur su~sequenl t(] this agreement as a result of faulty equipment, ins;alJati~n and/or damage by constructiort Since[ely, / , ,~/'¥ ,,';lt.'MI..,'.~,-':Z'""/ '- .i"" Gaykind Moore FIRE MARSHAL, ENFD q798 Davit, Boulevard / Naples. Fl_ FAX (8t3) 774-3782 33942 ' (013) 7'74-7111 / OFFICE OF TI~ FIRE MARSHAL East Naples Fire Control and R~seue District Fl RF~._HYD~,kNT t,,' _LQ~ IN'VOICE Te~t Req~estcd ~¥: JLm Steven~ Specific Lc..cat,,i. on: P~Uca~ Lake Static Prcssure: 78 Flydririt #: now Fire l~,to~ t~ 20 p~,i l'~c~idual Mfu,~ Pressure,: 1481 opm Inspect/on Fee Due: $~5.00 Post-it¢ Fax Note 7671 ID~ie ~//~,, [?_?,,..j I~'' "~ #of ~, June 2, 1997 Mr. Thomas Kuck, P.E. Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 Subject: Pelican Lake R. V. Resort Unit One Fire Flow Certification Dear Mr. Kuck: Please accept this letter as representation that in our professional judgment and to the best of our knowledge and belief, the water mains have been designed to provide fire flow to the project as reviewed and approved by Collier County Engineering Review Services. If you should have any questions, please do not hesitate to contact our office. Sincerely, WILSON, MILLER, BARTON & PEEK, INC. Stephen A. Means, P.E. Vice President CC: Norm Wilder, Pelican Lake Limited Jim Stevens, J.D., Ltd. Dory Nitch, WMB&P, Inc. Engineer's Signature and Seal 6/2197 - W-02370053.DEN 237-3-cor WILSON, MILLER, BARTON cS>t PEEK, INC. 3200 Bailey Lane, Suite 200, Naples, Florida 34105-8507 ' Ph 941-649-4040 Fx 941-643-5716 Web Sire: www. wilst~t~niller, ctm~ E-mail: naplcs@wilsonmiller.com G!LLIER COLNTY ~~ ~~: ............. - , , ~,, . --- -~ _ ~: ...... _ ......... ~ _ __ ~ · - -~., . acro~ ch~c~. ~Id not o~n [ ] a~rom~ ~heck , . .l~k~ [] cl.mned ~nl~' [] .=lean-d. only [1 cIeaned only [] ,.=!ea ea only r~be= k~t [] ~ber klU [] ~ber. k~= '[ ~bmr .kit [] ~ asae~ly [] RV assa~ly [] ~'asse~iy [] '~.,mm~'m~ly [] O~ or or ..'diso., mir in [] loCk nu~s [3 o:her [] lock' nu~8 'across-chsck opened at ',.-~c~o~l check.. '" ............. valve p~l pal val~ ' psi c~::~alve ~ psi COLLIER. COLNTY, CROSS CONNEC' , .ON CONTROL STREET ADDP~SS, _ LOCATION' OF A~9~LY: valve l~$ i, [] cleane~ only repl&~ed ~ r~ber k i~ ~ ~ re~&tn~r r '; o~hsr [] . - - 7~..~ ..... ~ .. gaug~ leaked cloued ~ igl~t acrol~ cheek' v-~ive ~ psi kit [] O~ ~-rings ~pring [3 Icem/~T~Ide [] lock nu~a [] other [] a~.r .inlet opened le~kbd' [ held a.t __ p~i cleane~ only rul~ber ki~ [] disc, air in [2 eprin~', air [] ,pztn~, CV [] ~tdo [) D-ring [ ] ~'. ocher: [ } air inlet _ . psi TESTER: ~r' ] .~,.~::~2L::::L .... CENT. 'NO: _..~~ OATm: ~//.~ /'g 7, , -- -" ; --F ~ - .~.~,~,.~' ' ' , , : -; : . SANITARY SEWER SYSTEM INFILTRATION REPORT PROJECT: CRITERIA: *50 gallons per inch of internal pipe diameter per mile.per day including manholes or as required by the specifications. An infiltration and/or inflow observation was made on the subject project. The results are as follows: ~ *Gal Z~ LF x ~ in. Dis x 50 Day 5280 LF in. Dia MI x 1 gal 24 hr x 60 gal. = ~),/L~ min day min From To. MH~-~ MM9 | ~l~. Gallons per Minute Measured Gallons p~r Minute Allowable Prepared by: ~~ Revised 1/86 G1 SANITARY SEWER SYSTEM INFILTRATION.REPORT PROJECT: DATE: . -Io-q7 CRITERIA: *50 gallons per inch of internal pipe diameter per mile per day including~manholes or as required by the specifications. An infiltration and/or inflow observation was made on the subject project. The results are as follows: , *Gal 3~ LF x [0 in. Dia x 50 Day 5280 LF in. Dia MI x 1 9,al 24' hr x 60 gal. = g$,/~d~ min day min From · To ~ I MH~ 7 Gallons per Minute Measured Gallons per Minute Allowable Prepared bY:/~~~- //~'~~ Revised 1/86 G1 ~.~.~_INC~ TEL:l-813-275-8874 3un 30,97 13:28 No.O02 P.02 CHARLES AMRHEIN m A & G ELEcTRIc INc, 17540 Oak C~'eek Rd. Alva, Florida 33920 (813) 728-3787 e..eep.er 408~m423 · : · :. To Whom It Ma~ Coaeem: ; .... .., Re: Pelican Lakc R.F. Resort, Unit one,"$eW~r Lift S~tion 'I'~ cl~c se~i~ m ~c Pelican ~ke g~r lift ~fion w~ insmll~ ~ ~ ~c ~pm~ pl~s and s~cifications. ' ~e line ~!age ~p ~s not ~ 5%.'.. - CA/smr DIVISION OF ELLIS K. PHELPS & CO, 2152 SPRINT BLVD. APOPKA, FL 32703 (407) 885-3t31 RESPOND TO: ,586~[ DIVISION DRIVE ~ 1100 53RD COURT SOUTH FORT MYERS, I~L 33905 MANGONIA PARK (56~) 848-2299 PUMP STATION START-UP REPORT [] 124 AIRPORT PARK OR, SAVANNAH. GA 31408 JOB NAME PELICAN LAKES RV RESORT LOCATION OF STALLATION Naples~ FL CONTRACTOR RDMC Incorporated DESIGN CONDITIONS: GPM__ ~UMP MODEL CP3102 H.P. 4 IMPELLER 436 VOLTAGE 230 PHASE SERIAL NUMBER #! 180-9710817 ~2 180-9710818 ~3 MANUFACTURER OF CONTROL OVERLOAD HEATER ~ B-28 ALTERNATOR T~$TED YES OPERATOR Collier County ' #4 QCI SERIAL L/A CONNECTED YES TDH 1 02-97-04 GROUND CONNECTED YES COMMENTS: Ail controls operate good. Pumps sound good. H~GGER CHECK #1 INF RED INF BLACK ~2 INF RED INF BLACK #3 RED BLACK ~4 RED BLACK VOLTAGE CHECK: INF WHITE INF WHITE WHITE WHITE CONTROL CIRCUIT PRIF~RY 125 A to B 249 E to C XZ A to G 125 B tO G 125 AMPERAGE CHECK: ~1 16 A 15 B XX #2 16.5 A 15 B XX #3 A B PUMPS SEATED PROPERLY YES FIELD TEST PERFO9J~ANCE TEST: TO GROUND SECONDARY A to C XX A to G XX C PHASE C PHASE C PHASE 24 OPERATOR HAS RECEIVED INSTRUCTION MANUAL YES ~1343.2 GPM TDH #2334.4 GPM TDH BOTH GPM #3 GPM TDH #4 GPM /"~)TD~i-' BOTH GPM Of~icia! Start-U? Date; 6/25/97 TD~, TDH COLLIER COUNTY UTILITIES W~STEW~TER DEPARTMENT pROJECT VIDEO REVIEW DATE OF REVIEW: 05/16/97 PROJECT NAME: Pelican Lakes R/V Resort ENGINEER OF RECORD: N/A CONSTRUCTION CONTRACTOR: R.D.M.C. VIDEO CONTRACTOR: Sewer Viewerr Inc. COMMENTS: Lines and services are in qood condition, RECOMMENDATIONS: ~/~ACCEPTABLE: ~ REVIEW NUMBERED COMMENTS IN ONE YEAR: i I NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) ~---~OTHERRECOMMENDATIONS: Reviewed by; Stephen L. Nagy Sr. Utility Tech. COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT SERVICES DIVISION 2800 NORTH HORSESHOE DRIVE NAPLES, FL 55942 (941) 645-8400 PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION A CERTIFIED BLUE CHIP COMMUNITY June 13, 1997 Kevin Ledbetter Wilson, Miller, Barton & Peek 3200 Bailey Lane, Suite 200 Naples, Florida 34105 RE: "Pelican Lake R.V., Phase I" Water & Sewer Dear Mr. Ledbetter A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on June 13, 1997 Conditions were found to be acceptable, and appear to meet County Standards. If you should have any questions, please do not hesitate to call Randy Casey at (941) 643-8418 or Clyde Fugate at (941) 643-8417. Sincerely,_ Engineering Inspection Supervisor CF/rc/mk/c:\Inspection form CC: Cindy Erb, Engineering Technician, Public Works Timothy L. Clemons, Wastewater Director, Utilities Mike Newman, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section File