Loading...
Candlewood ThreeMEMORANDUM DATE: February 19, 2000 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II ~ Project Plan Review RE: Candlewood Three Water and/or Sewer Facilities Acceptance Recording Fee Number 113-138312-649030 On /~/~6~ /j~, , ~9~The Board of County Commissioners granted final acceptance of the water and/or sewer facilities within the above-referenced project. Attached, 1. 2. Also, please find the following recorded, in order: Bill of Sale Utilities Facilities Warranty Deed please find attached the following documents for your files. 3. 4. 5. t0. 11. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities DER Placement-in-Service letter for sewer facilities Contractor's Final Release of Lien Lab results on bacteriological test for water lines Memorandum to Maureen Kenyon, February 19, 2000 Page Two Supervisor, Clerk to Board 12. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 13. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 14. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 15. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 16. Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing 17. Certification of the inflow/infiltration test for the sewer lines by Engineer of Record 18. Coating certification of man holes, wet wells and dry well from manufacturer 19. Copy of video tape test report 20. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations If you have any questions, please call and advise accordingly. attachments doc:2094-2 I)wighl I,:. I~rock Clerk County of Collier CLERK OF TIlE CIRCIJIT COURT COLLIER COUNqY COURTHOUSE 3301 TAMIAMI TRAIL EAST PO BOX 413044 NAPLES FLORIDA 34101-30~14 OFFICIAL RECEIPT Who. Validated BRANCH OFFICES: GOLDEN GATE 4839 GOLDEN GATE PARKWAY GREENTREE SHOPPING CENTER 2386 IMMOKALEE ROAD IMMOKALEE 101 S FIRST STREET MARCO ISLAND 1040 WINTERBERRY DRIVE EVERGLADES CITY 207 BROADWAY AVENUE DESCRIPTION AMOUNT DUE f:;:ECOI:~:[)i?IG Of:: LEGAL IFi'3"FRUhlEt'I I::', I: ,. ~i. q-, F . F::E CORD i I',IG F E E 4,00 DOC TYP FILE ID BOOK PAGE [,El::' ~: L"i( tOTAL DUE: 30.70 2594455 OR: 2641 PG: 3128 ~OR~I~ in O~CI~ ~ICOI~S of COLLI~ COUN?L ~L 02/16/2000 at ll:t&~ DVIGH? ]. BRO~[, CLllK RB¢ FIB 15.00 Retn: SHIR~I~ NIX H? 5§86 BILL OF SALE THIS BILL OF SALE evidencing the sale and conveyance of the water and sewer facilities described herein is made this o~, c~ day of July, 1999, by PEEK - BENDER, INC., a Florida corporation, whose post office address is 90 East Avenue, Naples, FL, 34108 (hereinafter referred to as "Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF COLLIER COUNTY WATER-SEW~,~R DISTRICT, its successors and assigns, whose post office address is Collier County Courthouse, 3301 E. Tamiami Trail, Naples, Florida, 34112 (hereinafter referred to as "Buyer"). WITNESSETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: See attached Exhibit "A". The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as water and sewer utility facilities; that said goods and chattels are free from ali liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. OR: 2641 PG: 3129 SIGNED, SEALED AND DELIVERED IN THE PRESENCE OF: Witness ~i{ness Print Name PEEK - BENDER, INC., a Florida corporation Thomas R. Peek, President STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was acknowledged before me by Thomas R. Peek, President of Peek Bender, Inc., a Florida corporation, pursuant to authority duly vested in him by the corporation this day of July, 1999. This instrument prepared by: James A. Pilon, Esq. Siesky, Pilon & Wood 1000 N. Tamiami Trail, Suite 201 Naples, FL 34102 (941) 263-8282 Notary Public - State of Florida Personally Known ~'/ Or Produced ID __ ID produced N O F:LAPp S/V~P51 \ JPDOC $\CANDLEWOOD BOS wpd EXHIBIT A 3130 The South ~ of the Northeast 1/4 of the Northwest 1/4 of the Northwest 1/4 of Section 24,'Township 48 South, RanEe 25 East, Collier County, Florida 2594456 OR: 2641 PG: 3131 SNGINSRRISG RRVIR# ISR¥ICSS PlCO~SD in the 0PFICIIi I~CORDI of COLLISR C01I]~TY, FL II{IItLS! SIX 02/16/2000 it 11:1611 DSlGH? !. SilO(III, CLSlfl[ WATER AND SEWER UTILITY FACILITIES WARRANTY DEED RFC FSI DOC*. 70 16,00 ,70 THIS INDENTURE made this ~ q r~. day of July, 1999 between PEEK- BENDER, 1NC., a Florida corporation, v~nosc post office address is 90 East Avenue, Naples, Florida 34108, (herein referred to as "Grantor"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF COLLIER COUNTY WATER-SEWER DISTRICT its successors and assigns, whose post office address is Collier County Courthouse, 3301 East Tamiami Trail, Naples, Florida 34112 (hereinafter referred to as "Grantee"). WITNESSETH: That said Grantor, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Grantor in hand and paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all water and sewer utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said water ..~nd sewer utility facilities, situate, lying and being in Collier County, Florida, to wit: See attached Exhibit "A". and said Grantor does hereby fully warrant the title to said water and sewer utility facilities, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A". Grantor and Grantee are used for singular or plural, as context requires. 1N WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. SIGNED, SEALED AND DELIVERED IN THE PRESENCE OF: Witness P_'.~. Name a~d Title 7 i ness Print Name and Title GRANTOR: Peek-B~Ter'flv~c' , /~ Thomas R. Peek, President OR: 2641 PG: 3132 STATE OF FLORIDA COUNTY OF COLLIER The foregoing instrument was acknowledged before me by Thomas R. Peek as President of Peek-Bender, Inc., a Florida corporation, pursuant to authority duly vested in him by said corporation, on this ~. c7 day of July, 1999. (SEA[) This instrument prepared by: JAMES A. PILON SIESKY, PILON & WOOD 1000 Tamiami Trail North, Ste. 201 Naples, FL 34102 (941) 263-8282 Notary Public Print Name: My Commission Expires: EXHIBIT A *** OR,,~ 2641 ?G: 3133 *** : The South ~ of the Northeast 1/4 of the Northwest 1/4 of the Northwest 1/4 of Section 24, Township 48 South, Range 25 East, Collier County, Florida OWNER..~' ~ AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLIER On this 2. q r~, day of July, 1999, personally appeared before me THOMAS R. PEEK, PRESIDENT OF PEEK-BENDER, 1NC., a Florida corporation owner of property to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of water utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to the Owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now installed in the aforesaid premises. Affiant further says that the utility facilities described herein are not included in, encumbered by, or subject to any real property mortgage, chattel mortgage, security agreement, Uniform Commercial Code financing statement, or any other encumbrance. Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A". AFFIANT: Peek-Bender, Inc. By: ~7~J j~'/~ Thomas R. Peek, President SUBSCRIBED AND SWORN before me this .~ c7 day of July, 1999, by Thomas R. Peek as President of Peek-Bender, Inc., who is personally known to me. Notary Public (SEAL) Print Name:/D/-%e/_er~'e_ ~. _5/9/-~ My Commission Expires: This instrument prepared by: JAMES A. PILON SIESKY, PILON & WOOD 1000 Tamiami Trail North, Ste. 201 Naples, FL 34102 (941 ) 263 -8282 EXHIBIT A The Soulh ¼ of the Northeast 1/4 of the Northwest 1/4 of the Northwest 1/4 of Section 24, Township 48 South, Range 25 East, Collier County, Florida ATTOKNEY'S AFFIDAVIT STATE OF FLORIDA COUNTY OF COLLiER ON THIS 9t~ day of August, 1999, before me personally appeared JAMES A. PILON, a licensed attorney authorized to practice in the State of Florida, to me personally known, whose current business address and telephone number are: Siesky, Pilon & Wood, 1000 N. Tamiami Trail, Suite 201, Naples, FL, 34102, 941-263-8282, (hereinafter "Affiant"), who, being duly sworn on his oath, does say: 1. This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of Collier County Water-Sewer District to accept the conveyance of water and sewer utility facilities located within or upon the real property described in the attached Exhibit"A", which is incorporated herein by reference, said land being located in Collier County, Florida. 2. The Affiant has examined record title information to the real property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 3. The record owner of the real and personal property described herein is PEEK - BENDER, 1NC., a Florida corporation (hereinafter "Owner"). The Owner acquired record title to the subject real property by instrument recorded November 16, 1998 at Official Records Book 2480, at Page 2939, Public Records, Collier County, Florida (copy attached). 4. The Affiant has examined corporate information obtained from the Secretary of State of Florida. PEEK - BENDER, INC. is a current and active Florida corporation; PEEK - BENDER 1NC. is authorized to do business in the State of Florida and THOMAS R. PEEK is President of PEEK - BENDER, iNC. and is authorized to execute instruments on behalf of PEEK - BENDER, INC. in conjunction with the conveyance of water and sewer utility facilities. 5. The Affiant states the subject real property is unencumbered and the real estate taxes are current. 6. Affiant further states that the information contained in this Affidavit is true, correct and current as of the date this Affidavit is given. FURTHER AFFIANT SAYETH NAUGHT Dated this ~) day of August, 1999. ~(d'AMES A. PILON SUBSCRIBED AND SWORN to before me this Pilon who is personally known to me and who did take an oath. day of August, 1999, by James A. }~ "., ~;~'.; Commisslor: No, CC 60210_ ~ A .i~ tNotary Public Printed Name of Notary My commission expires: This instrument prepared by: James A. Pilon, Esq. Siesky, Pilon & Wood 1000 N. Tamiami Trail, Naples, FL 34102 (941) 263-8282 Suite 201 The South '~ of the Northeast 1/4 oft. he Northwest I/4 of the Northwest 1/4 of Section 24, Township 48 South, R~ge 25 East, Collier County, Florida ~,~ m N,,{,.,':. 00163840000 Warranty Deed Thialndenmre, Mad~thla loth dayof November ,1998 &D., I~etw~n ........................ TEN DOLLARS ($10) ....................... Northwest 1/4, Sectiou 24, Township 48 South, Range 25 East, Collier the subdivision and taxes for the current year and subsequent years. The property herein conveyed DOES NOT constitute the HOMESTEAD property of the G~antor. The Grantor's HOMESTEAD address is 390 Doris L. B~nder, Trustee of the George Bender Revocable Tr~st Agreement date~ October 23, 1997 STATE OF Florida COUNTY OF Collier - ' ~---~ ?~ No=a~ P~lia COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOP~'qT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION December 23, 1999 Planning Services Deparhnent 2800 North Horseshoe Drive Naples, Florida 34104 Stephen A. Means Wilson, Miller, Barton & Peck, Inc. 3200 Bailey Lane, #200 Naples, FL 34105 Re: Candlewood Three Dear Mr. Means: This is to inform you that the above referenced project has been granted preliminary approval on November 30, 1999 by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, Shirley Nix`/ Engineering Technician II CCi Joe Cheatham, Wastewater Director Paul Mattausch, Water Director Diane Deoss, Public Works John Houldsworth, Engineering Review Phone (941) 403-2400 Fax (941) 643-6968 www.m~Ml~r, fl.m COLLIER COUNTY GOVERNMENT COMMUNFrY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION ENGINEERING REVIEW SECTION [qnnnin~ Services Department 2800 North Horseshoe Drive Naples, ~lorida 34104 October 8, 1999 Mr. Steve Means, P.E. Wilson Miller 3200 Bailey Lane Naples, FL. 34105 Re: Candlewood Three Dear Steve: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3.2.6.5.2. All water and sewer facilities approved and accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections, the Board of County Commissioners shall adopt a resolution giving final approval of the required improvements, acknowledging the dedication(s) of the final subdivision plat and establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, John~.-~ouldsworth Senior Engineer cc: Shirley Nix Phone (941) 403-2400 F~x (~41) www.¢o.comer.lL-. Wils nMiller New Directions In Planning, Design & Engineering July 29, 1999 Mr. Thomas Kuck, P.E. Project Plan Review Collier County Development Services Center 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: Candlewood Three Utility Dedication Engineer's Payment Confhnnation Collier County Conveyance Document Checklist, Legal Document Item 16 Dear Mr. Kuck: Wilson Miller confirms receiving payment for our services to date on the subject project. As of this date, no monies are outstanding from the owner/client. Sincerely, WilsonMiller, Inc. Stephen A. Means, P.E. Vice President Naples Fort Myers Sarasota Bradenton Tampa 3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105-8507 941-649-4040 ~ 941-643-5716 wwat. wilsonrniller, corn WilspnMiller New Directions In Planning, Design & Engineering July 29, 1999 Ms. Shirley Nix Collier County Engineering Review Services 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: Candlewod Three Utility Testing Results Dear Ms. Nix: The following attached tests for the subject project are in our professional judgment and to the best of our knowledge and belief representative of actual field conditions on the date performed: 1. 6" watermain pressure test, dated 5/21/99 2. Inflow/infiltration test, dated 7/12/99 If you should have any questions, please do not hesitate to contact our office. Sincerely, WilsonMiller, Inc. Stephen A. Means, P.E. Vice President Enclosures Engineer's Signature and Seal Naples Fort Myers Sarasota Bradenton Tampa 3200 Bailey Lane, Suite 200 Nap/es, F/or/da 34105 8507 941-649-4040 ~ 941-643-5716 HYDROSTATIC TEST REPORT Date of Test The computed allowable leakage tbr the test section is (calculations attached) ~)..~. The maintained test pressure for the test duration was I...%0 psi. The measured leakage during the test was O, O ~ Gal. The duration of the test was ~ Hrs. The measured leakage was 0.0 ~ Gal. Hr. The method of measurement was Meter Calibrated Drum t~' The hydrostatic test for this section meets ~ does not meet the allowable leakage. Project Type of Main w.o. ~ O.~l[7- Plan File Supt. ~ Field Rep. Gal. Hr. WILSON, MILLER, BARTON & PEEK, INC. ie)0 Representative Jeb Bush Department of Environmental Protection South District P.O. Box 2549 Fort Myers, Florida 33902-2549 David B. Struhs Secretar-/ Robert Bender, Vice President Peek-Bender, Inc. 90 East Avenue Naples, Florida 34108 Re: October Il, 1999RECEIVED WILSON MILLER OCT I 3 1999 FOL~ER ~ ~ogL(~ Collier County - PW C~dlewood III (Collier County Regional ~P) 154354-001-DSGP Dear Mr. Bender: This acknowledges receipt of certification that the subject water distribution system extension has been completed in accordance with the plans and related materials permitted by this agency under Permit Number 154354-001-DSGP dated May 5, 1999. Based on this certification and satisfactory bacteriological results, we are approving these facilities for service under the following conditions: If the bacteriological samples were collected prior to replacement of the temporary backflow preventer or temporary construction meter with a final connection, then additional bacteriological sampling is required. Upon completion of the final connection, collect a bacteriological sample immediately downstream of the connection and submit the bacteriological results to the Department. Immediate service can be provided ifa precautionary boil water notice is issued for areas down stream of the connection, until one day of satisfactory bacteriological results have been obtained (Two consecutive days of satisfactory bacteriological results are required following any unsatisfactory result). Your continued cooperation in our water supply program is appreciated. Sincerel)K--'-,x Professional Engineer Water Facilities CRD/MFJ/skw cc: Stephen A. Means, P.E? Thomas E. Kuck, P.E. "More Protection, Less Process" Prmted on recycled paper. Florida Department of Environmental Pro_t_eetiom T~v,n ~ro,~, Of,~c~ .,d~., 2600 ",a,r Sto.~ Road, ~.,,aha,,~c, ~,o~da :~E~C~E I VED WILSON MILLER ~q£T 0 6 1999 FOLDER DOMESTIC WASTEWATER COLLECTION/TRANSMISSION SYSTEMS ~.. CERTI~CATION OF COMPLETION OF CON'RUCTION i' INSTRH~IONS: ~is form is to be complet~ and sub~tt~ to the Depa~ment, prior to placing the systm into operation. A collation/transition system should not be plac~ into operation without prior Department approval. All info~tion is to be typ~ or pfint~ in i~ and all bla~s must be fill~. ~nstmctlon Pe~t No.: _ 50581-117.DWC Name of Proj~t: Candlewood Ill Dat~: _ Mag 5, 1999 Name of O~er: Peek-~er Inc.. Name of d~ign engin~r and Florida registration number (if different from engin~r signing ce~ification): Date(s) connection to existing system or treatment plant: ~ f."r, Treatment plant serving project Name: North Collier Reeional WWTp County:. Collier DEP Identification Number (also known as WAFR or GMS Identificat Substantial deviations from the approved plans and specifications City: ~anles aN Page. I of 3 SEP 2 4 1999 DZ.p.. SOUth District FINAL RELEASE OF LIEN KNOII': ALL BIEN B'I~ THESE PRESENTS: That the undersigned, for and in consideration of the payment of the sum of ........... ~.E.V.I~i~.T.E.I~N...T~I.O.U. ~.~.D..?I]t.R~.E..t]I.U~,I.D.P~E..I)..S.E.I{~] .N?f..q~.Wp.. and ............ 5.0/100 Do II ars ($J' ~.'.3.7. ~: ~.0... ) paid by the ......... P..E.E~ .B..E.N~).~I~..I.N.C... ...................... receipt of which is hereby acknowledged, hereby releases and quit claims to the said . .PE~K .BENI).ER. IN.C ......................................... its successors and assigns, and ....................................................................... the owner, all liens, lien rights, claims or demands of any kind whatsoever, which the undersigned now has or might have against the building on premises legally described as WATEIl AN]) SRWER FACTLITIES FOIl .... qA.N.p.~w, qgp' .3.:..N.A.P.L..~.S.,..qg.~h.!E.R.. 9P.q~T¥~. ?.~9.R~PA., ......................................... on accountof labor performed and/or material furnished for the construction of any improvements thereon. That all labor and materials used by the undersigned in the erection of said improvements have been fully paid for. IN WITNESS WHEREOF, I have hereunto set my hand seal this ...... .L2.~H ............ day of ........ .J.U.L.Y. .................. , 19 99 STATE OF FLORIDA ) COUNTY OF LEE~ ss. I hereby acknowledge that the statements contained in the foregoing Release of Lien are true and correct. B K ......... HARLAN HASKINS, PRESIDENT 12 TH JULY 99 Sworn to and subscribed before me this .............. day of .......................... , 19 ....... My commission expires: // ~l, nj/ ~\'t~l,t~9' Pithily' St, tie (~f-l:/orid, t COLLIER COUNTY GOVERNMENT PUBLIC WORKS DIVISION 3301 E. TAMIAMI TRAIL NAPLES, FLORIDA 34112 (941) 732-2575 FAX: (941) 732-2526 November 05, 1999 JP Murphy, Inc. #2 Pepita Street Fort Myers Beach, FL 33931 Re: Bacteriological Analysis Results - Main Clearance Attached please find the analytical results on the following water main clearance project: Candlewood Phase 5. These results were found to be acceptable by Collier County LaboratoIy, #55261. Should you have any further questions regarding this matter, please contact me at (941) 352-7004'. Sincerely, Howard B. Brogdon Laboratory Supervisor State of FLorida Oepart=ent of Health Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, Uest Palm Beach DRINKING WATER BACTERIOLOGICAL ANAL YSIS FOR LAB USE ONLY Press hard, (5) copies SYSTEM NAME: SYSTEM I.D. NO: SYSTEM PHONE #: ADDRESS: COUNTY: D I STR I CT: COLLECTOR: SAMPLE SITE (Locality or Subdivision): COLLECTOR PHONE #: DATE AND TIME COLLECTED: Private well Swimming pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement Main clearance Well survey Other (Check Box) [ ] Distribution [ ] Check here if pa)q~ent made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR_O~F_SAMPLE TO BE COMPLETED BY LAB ANALYSIS METHOD: MF MTF MMO-MUG PA COLL. SAMPLE POINT CI --NON CONFIRM CONFIRM NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COL[ SAMPLE NUMBER I Results in this column are presumptive. Total coliform and fecal coliform or E. co[i confirmation will follow in 24-48 hours. P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliform~ are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS'REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES StAte of FLorida Depart~eflt of Hearth Office of Laboratory Services Jacksonville, Miami, Pensacola Tampa, West Palm Beach DRINKING WATER BACTERIOLOGICAL ANALYSIS FOR LAB USE ONLY Press hard, (5) copies SYSTEM HAME: SYSTEM I.D. NO: SYSTEM PHONE #: ADDRESS: COUNTY: DISTRICT: COLLECTOR: COLLECTOR PHONE #: SAMPLE SITE (Locality or Subdivision): DATE AND TIME COLLECTED: TYPE OF SUPPLY(Circle one): Con~nunity water syst~n Noncon~nunity water system Nontransient - nonco~unity water system Private well Swirling pool Bottled water Limited Use system TYPE OF SAMPLE(Circle one): Compliance Repeat Replacement Main clearance Well survey Other (Check Box) [ ] Distribution [ ] Check here if payment made [ ] Raw to county public health unit TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY LAB ANALYSIS METHOD: MF MTF MMO'~UG PA COLL. SAMPLE POINT CI NON CONFIRM CONFIRM I NO. (Specific Address) RES'D pH COLIFORM *TOTAL TOTAL FECAL E. COLII SAMPLE NUMBER Results in this column are presumptive. Total coliform and fecal coliform or E. coli confirmation will follow in 24-48 hours. P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INVOICE ADDRESS (if different than address below): INTERPRETATIONS-REMARKS BY. PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING OFFICIAL: TITLE: ( ) ( ) SATISFACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES Wils nMiller New Directions In Planning, Design & Engineering August 3, 1999 Mr. Thomas Kuck, P.E. Project Plan Review Collier County Development Services Center 2800 North Horseshoe Drive Naples, FL 34104 SUBJECT: Candlewood Three Utility Dedication Engineer's Certification Dear Mr. Kuck: Please accept this letter as representation that in our professional judgment and to the best of our knowledge and belief the potable water distribution and sanitary sewer collection systems as listed below for Candlewood Three have been completed in substantial accordance with the plans (WM FILE NO. D-03117-02) and specifications approved by Collier County Engineering Review Services. Furthermore, to the best of our knowledge and belief the subject water and sewer facilities have been constructed by the contractor within the public right-of-way and/or dedicated easements. Please contact me should you have any questions regarding this matter. Sincerely, WILSONMILLER, INC. Stephen A. Means, P.E. Senior Vice President Engineer's signature and seal llaplos Fort Myers Sarasota Bradanton Tampa 3200 Bailey Lane, Suits 200 Nap/es, Florida 34105 8507 941-649-4040 ~ 941-643-5716 WARRANTY The undersigned parties do hereby warramy and/or guaranty all work executed by the contractor on CANDLEWOOD 3, NAPLES, FLORIDA, to be free from defects in material and workmanship for a period of at least one year after the COLLIER COUNTY BOARD OF COUNTY COMMISSIONERS acceptance for water and sewer facilities. The undersigned parties further agree that they will, at their own expense, repair and replace all such defective work. It is furthermore understood that the consideration for the giving of this warranty and/or guaranty is the requirement by the general conditions and specifications under which the contract was let that such warranty and/or guaranty would be given. CONTRACTOR: HASKINS INC. (CORPORATE SEAL) ~AN HASI~[N~S, ~RESIDENT STATE OF FLORIDA COUNTY OF LEE The foregoing instrument was acknowledged and/or sworn to and subscribed before me this day of June, 1999 by Harlan Haskins, President of Haskins Inc. who is personally known to me. ~)TARY PUBLIC STATE OF FLORIDA My commission expires: Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt i Tran~ Number I E)a~ ' I Post Date ~ayment ~lip Nbr 1~7215 J08/18/1999 I 07:35 PM ~0_-~)-~8/1999 ~UT 57782 CANDLEWOOD PH II PALM RIVER FULL BORE FLUSH DOR 502 Payor: J P MURPHY Fee co~ Description ] 42CYIN COUNTY INVOICES Fee Information t (~'L Account 51 Amount 40800000011510000000 i $187.28 Total Waiv~ $187.28' Payments Pa~ym~n~ Code [ Acc~unt/Che~;k ~mber ' ] ~rnount_ CHECK ~ 1669 I $187,28 Total Cash Total Non-Cash Total Paid $187.28/ $i87.281 Memo: J P MURPHY #2 PEPITA STREET FT MYERS BEACH, FL 33931 Cashier/location: FROLOFF_E / 1 User: MURNANE_G Collier County Board of County Commissioners CD-Plus for Windows 95/NT Printed:08/18/1999 1:08:03 PM Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number 160317 1Date I Post Date 0/;1~21999 ~0:b0:48 AM ~8/1999 ~Payment Slip Nbr ~UT 6111~ ~ JP MURPHY CANDLEWOOD PH-5 INV#DOR584 WO#21944 Payor: HASKINS INC Fee Code ~ Description ! 4~c~'il~ COUNTY INVOICES Fee Information ~ount -- - Amo~': 40] 408000~001~510000000 _$26~ Payments Payment ~ode ~ccount/check Number CHECK ~ 29691 Total Cash $0.~ Total Non-Cash '_ $262.38~ Total Paid I $262.38~ Memo: J P MURPHY 10956 ENTERPRISE AVE NAPLES FL 33923 Cashier/location: TERILLA_J / 1 User: CORZO M Collier County Board of County Commissioners Printed:10/18/1999 10:03:34 AM CD-Plus for Windows 95/NT N0~/--22--99 11:41 AM P. ~1 No=th Fi=e Co t=ol & FIRE PREVENTION BUREAU 1780 Immokalee Road · Naples, Rodda 34110 (941) 597-9227 · Fax (941) 597-3522 November 18, 1999 escne Dis{rlct Peek Benderlnc 90 East Avenue Naples, FL 34108 Re: Fire Hydrant Acceptance Candlewood Three Dear sir, The North Naples Fire Control and Rescue District has inspected for ownership and maintenance on the above hydrants. We have received payment for the above hydrant(s) and now accept ownership and maintenance. $12500 per hydrant times number of hydrants 2 = $ 250.00 $23.00 per thrust block times number of hydrants 2 = $ 46.00 one flow charge at time of acceptance $35.00 = $ 35.00 Following are the results of the flow test: Static: 76 Residual: 44 Flow: 1036 Pilot: 38 Total: $ 331.00 If you have any questions, please do not hesitate to give me a call at 597-9227. Singerely, Kart K Reynolds, Fire Marshal Fire Prevention Bureau Pd in full: Ck 143 Date: 11/18/99 SANTTARY SEWER SYSTEM I'NFZLTRATI'ON REPORT Project: Date: Criteria: *50 gallons per inch of internal pipe diameter per mile per day including manholes or as required by the specifications. An infiltration and/or flow observation was made on the subject project. The results are as follows: *gal. --' ~¢~(-~ LF x~> in. Dia. x 50 day x 1 = qal. 5280 LF in. Dia. 24 hr. x 60 gal. /~, (~,~ min. M! day min. From ¢"~. MH# ~, To MH# _~ Gallons per Minute Measured /"~. ,,'~) GPM Gallons per Minute Allowable GPM Revised 6/99 Jul-21-99 06:32A Haskins Inc. 3857 P. O1 -- t?,l ~'02 IlL P.~ '~)~ 15:25 "The Finest in Wastewater Structure Rehabilitation!" 44~1 Haftcock Brid;e Purk~ay * Nth. Ft. Myers. FL 33903 * 941-~)?-6645 * 041-~)~r;-'/ll? {"AX DATE OF REVIEW: PROJECT NAME: COLLIER COUNTY UTILITIES W'ASTEW/~TER DEPARTMENT PROJECT VIDEO REVIEW 8-4-99 Candlewood Three (North) ENGINEER OF RECORD: CONSTRUCTION CONTRACTOR: VIDEO CONTRACTOR: Omni Eye Inc. COMMENTS: Acceptable RECOMMENDATIONS: ~ ACCEPTABLE: Gravity line looks good REVIEW NUMBERED COMMENTS IN ONE YEA_R: NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) OTHER RECOM/~ENDATIONS: COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION July 15, 1999 Mr. Steve Means Wilson, Miller, Barton & Peek, Inc. 3200 Bailey Lane Naples, FL 34105 RE: Candlewood III, Water & Sewer Dear Mr. Means: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on July 15, 1999. Conditions were found to be acceptable, and appear to meet County standards.. If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418 or Clyde Fugate at (941) 403 -2417. Engineering Inspections Supervisor CF/ts/c:\Inspection form Water & Sewer Cindy Erb, Engineering Technician, Public Works Acting Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section File Phone (941) 4013-2400 Fax (941) wv~v. co. collier, fl. us