Loading...
Carlton Lakes, Tract EMEMORANDUM DATE: April 16, 1999 TO: Maureen Kenyon, Supervisor, Clerk to Board FROM: Shirley Nix, Engineering Technician II~' Project Plan Review RE: Carlton Lakes, Tract E Water Facilities Acceptance Recording Fee Number 113-138312-649030 On ~/~'~/?/~ /Z , ~'~ The Board of County Commissioners gran[~d final acceptance of the water and/or sewer facilities within the above-referenced project. Attached, please find the following recorded, in order: 1. Utilities Facilities Subordination, Consent and Joinder 2. Bill of Sale 3. Utility Easement 4. Utilities Facilities Warranty Deed Also, please find attached the following documents for your files. o 9. 10. 11. Owner's Affidavit Attorney's Affidavit Copy of preliminary approval letter from Engineering Review Copy of cashier's check & receipt for maintenance bond Engineer's final payment confirmation Certification of pressure testing of water lines by Engineer of Record Bacteriological clearances (DER certification) for water facilities Memorandum to Maureen Kenyon, Supervisor, Clerk to Board April 16, 1999 Page Two 12. DER Placement-in-Service letter for sewer facilities 13. Contractor's Final Release of Lien 14. Lab results on bacteriological test for water lines 15. Verification of final cost (Detailed: quantities, sizes, unit cost, total cost, etc.) 16. Letter by Engineer certifying that all water and/or sewer facilities are located within the public right-of-way or dedicated easements 17. Contractual Guarantee for material and workmanship for a period of at least one year after the Board of County Commissioners' acceptance for both water and sewer facilities 18. Payment of water usage, laboratory and administrative charges for filling, flushing and bacteriologically certifying water lines from invoice prepared by the Utilities Division 19. Letter from fire district regarding ownership and maintenance of fire hydrants and certification of field fire flow capacity testing 20. Copy of backflow prevention assembly test report 21. Certification of the inflow/infiltration test for the sewer lines by Engineer of Record 22. Coating certification of man holes, wet wells and dry well from manufacturer 23. Copy of video tape test report 24. Letter from Compliance Services section certifying that the final inspection reveals that the Utility facilities have been constructed in accordance with County ordinances and regulations 25. One copy of utility easement Memorandum to Maureen Kenyon, April 16, 1999 Page Three Supervisor, Clerk to Board If you have any questions, please call and advise accordingly. attachments doc:2094-2 I)u'ighl E. Brock Clerk County of Collier CLERK OF TIlE CIRCUIT COURT COLLIER COUNTY COURTHOUSE 3301 TAMIAMI TRAIL EAST PO. BOX 413044 NAPLES, FLORIDA 34101 3044 GOLDEN GATE 4839 GOLDEN GATE PARKWAY GREENTREE SHOPPING CENTER 2386 IMMOKALEE ROAD IMMOKALEE 101 S FIRST STREET MARCO ISLAND 1040 WINTERBERRY DRIVE EVERGLADES CITY 207 BROADWAY AVENUE T'IE~ Jl r ~ L ~Fd' i::;: E C E I P T: i:,AYQF:: R E F:: 2~:~28045 i~P'ZZ5 !13 t3:33122 DOC TYP FILE ID BOOK PAGE !T;U}3OF;'.D 2463t:: ,:) i 2'53.~:~ 0 t 12 IE~ 'i~AL.. IE :;.:4. t:~ .3&~O2 2¢53.i: O I. 1 !5 OFFICIAl, RECEIPT When Validated DESCRIPTION AMOUNT DUE F:EE. OREING []F: LEGAL INS'I"RUMEN i:'.~:;:.l,t.'f',,F. RECORDING FEE 8.00 I:)OCUME!'i'!'ARY ..,fAttF~ - 70 1.40 I 782135 04/16/1¢9t? BILLED: 61,40 ANT PAIO: ,00 TOTAL DUE: 61.40 2463601 OR: 2536 PG: 0112 RECORDED in O~HCIAL RECORDS of COLLIER COUNT~, PL 0~/16/1999 at 09:13AM DWIGHT E, BROCK, CLERK ~C ~l 15,00 ~tn: UTILITY FACILITIES SUBORDINATION, CONSENT AND JOINDER _~,~S SUBORDINATION, CONSENT ~ER given this /~d~(clay of ,1998, by First Union National Bank eff,,F,,hn~, a National Association (hereinafter referred to as "Mortgagee"), in favor of the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns (hereinafter referred to as "County"). Mortgagee is used as singular or plural, as the context requires. WITNESSETH' WHEREAS, Mortgagee is the owner and holder of that certain UCC-1 Financing Statement filed with the Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank of Florida, N.A. recorded in Official Records Book 2128, Page 1637; as modified by instruments recorded in Official Records Book 2285, Page 1534, Official Records Book 2375, Page 2385, and Official Records Book 2462, Page 1661; and UCC- 1 Financing Statement recorded in O.R. Book 2128, Page 1662; all of the Public Records of Collier County, Florida, (hereinafter referred to as "Mortgage"), encumbering the premises legally described therein (hereinafter referred to as the "Encumbered Property"). WHEREAS, County has requested and received from the fee simple owner of the Encumbered Property non-exclusive easements for the installation and maintenance of utility facilities over and across a portion of the encumbered premises legally described in Exhibit "A" attached hereto and incorporated herein by virtue of this reference, which premises are hereinafter referred to as the "Easement Property." WHEREAS, County has requested that Mortgagee consent to, join in and subordinate its Mortgage to the interest that County has in the Easement Property to which request Mortgagee has agreed. NOW, THEREFORE, in consideration of TEN DOLLARS ($10.00) and other good and valuable consideration, the receipt of which is hereby acknowledged, the Mortgagee does hereby consent to, join in and subordinate the lien of its Mortgage to the grant of that certain easement described herein over, under, and across the Easement Property and any interest of the County in any utility facilities located therein or affixed thereto. Except as subordinated to the easement described herein over, under, and across the Easement Property or any utility facilities located therein or affixed thereto, said Mortgage shall remain otherwise in full force and effect. OR: 2536 PG: 0113 IN WITNESS WHEREOF, the Mortgagee has caused these presents to be executed the date and year first above written. Witnesses: Print Name Print Name First Union National Bank a National Association STATE OF COUNTY OF The foregoing Utilities Facilities Subordination, Consent and Joinder was acknowledged before me by ~'fiarnz}t ~3-aK..cir. l}, as ~',F', [/J~e_ ]O0"'f~2 of First Union National Bank a National Association. He~she is pe~rsona_!ly kn~)wn to me or has produced as identification. WITNESS my hand and official seal this/~/'~day of ~2C2/-', Notary Public , 1998. (affix notarial seal) Print Name ~,.' ..... My Commission E This Instrument Prepared By: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 597-7088 *** OR: 2536 PG: 0114 *** EXHIBIT "A" FOR USE BY CLERK OF COURT: 2463602 OR: 2536 PG: 0115 RECORDED in OPPI¢IA5 RECORDS o~ COLLIER COUNTY, FL 04/16/1999 at 09:13AM DWIGHT I. BROCK, CLERK ~EC H~ 15,00 Re~n: SHIRLEY NIX BILL OF SALE THIS BILL OF SALE evidencing the sale and conveyance of the water utility facilities described herein is made this t 3 day of ~)e~3~ , 1998, by NTC Development, Ltd., a Florida limited partnership (hereinafter referred to as "Seller"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX~OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns, (hereinafter referred to as "Buyer"). WITNESSETH: That said Seller, for and in consideration of the sum of Ten Dollars ($10.00) and other good and valuable consideration to said Seller in hand paid by the said Buyer, the receipt whereof is hereby acknowledged, has granted, bargained, sold, transferred, set over and delivered, and by these presents does grant, bargain, sell, transfer, set over and deliver unto the Buyer, and the Buyer's heirs, successors and assigns forever, all those certain water utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: (See Exhibit "A" attached hereto and incorporated by reference herein) The Seller, for itself and its successors, hereby covenants to and with the Buyer and its successors and assigns that it is the lawful owner of the said goods and chattels herein referred to as utility facilities; that said goods and chattels are free from all liens and encumbrances; that it has good right, title and authority to sell same, and that it will warrant and defend the same against the lawful claims and demands of all persons whomsoever. Seller and Buyer are used for singular or plural, as the context requires. OR: 2536 PG: 0116 IN WITNESS WHEREOF, Seller has caused these presents to be executed the date and year first above written. Witnesses: NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW Florida Partners, Inc., a Florida co oration, as General Partner Print Name _l'i")a,.,,~co ~ t~xc,nrcilc_ Its: President STATE OF FLORIDA COUNTY OF COLLIER The foregoing Bill of Sale was acknowledged before me by Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporation. as Sole General Partner of NTC Development, Ltd., a Florida limited partnership, w~ is personally kno~ tO nfe~,,~r who has produced identification. ' ..... - WITNESS my hand .artd official seal this - ~' ~ JOHN J STERLING I I~ ~ ~ ¢C730692 I /L OF: ~%O APR. 5,2002 J (affix notarial seal) This Instrument Prepared By: C. Perry Peeples, Esquire Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 597-7088 day of (~C.,~~ 1998. (Print Name) My Commission Expires: EXHIBIT "A" *** OR: 2536 PG: 0117 *** FOR USE BY CLERK OF COURT: 2463603 OR: 2536 PG: 0118 RECORDED in OFFICIA~ R~¢ORDS of COLLIER COUNTY, PL 04/16/1999 at 09:13AM DWIGHT E, BROCK, R~C F~ 15.00 ~oc-,?o Retn: ~NGINHRI~G RgVI~W ~[T 558~ UTILITY EASEMENT THIS EASEMENT, granted this ~ '3 day of C~ ~-~(, 1998, by NTC Development, Ltd., a Florida limited pannership, as Grantor, to the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER- SEWER DISTRICT, its successors and assigns, as Grantee. WITNESSETH: That the Grantor for an in consideration of the sum of ten dollars ($10.00) and other valuable consideration paid by the Grantee, receipt of which is hereby acknowledged, hereby conveys, grants, bargains and sells unto the Grantee, its successors and assigns, a perpetual, non- exclusive easement, license, and privilege to enter upon and to install and maintain utility facilities, in, on, over and under the following described lands being located in Collier County, Florida, to wit: See attached Exhibit "A" which is incorporated herein by reference TO HAVE AND TO HOLD the same unto said Grantee and its assigns, together with the right to enter upon said land, excavate, and take materials for the purpose of constructing, operating, and maintaining utility facilities thereon. Grantor and Grantee are used for singular or plural, as the context requires. OR: 2536 PG: 0119 IN WITNESS WHEREOF, the said Grantor has caused these presents to be executed the day and year first above written. Witnesses: NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW Florida Partners, Inc., a Florida corporation, as General Partner l~obert G. Claussen, President STATE OF FLORIDA COUNTY OF COLLIER The foregoing Utility Easement was acknowledged before me by Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporation, as Sole General Partner of NTC Development, Ltd., a Florida limited partnership, ~.~o i~-pers6-fially known to me~r who has produced as identification' .~ WITNESS my hand and official seal this ~_ day of ~:::z~ ~/-~--~..~ 1998. (affix notarial seal) Print Name My /~/~ /// Commission Exp!res:/ ,/ This Instrument Prepared By: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 597-7088 EXHIBIT "A" *** OR: 2536 PG: 0120 *** FOR USE BY THE CLERK OF COURT: 2463604 OR: 2536 PG: 0121 RECORDED in O~FICIAL Rg¢ORDS of COLLIER COUNTY, PL 0~/1fi/1999 at 09:13AM DWIGHT ~. BROCK, CLERK ~c ~ 15.00 DOC-.?O ~etn: S~I~L~i NIX HT 5586 UTILITIES FACILITIES WARRANTY DEED THIS INDENTURE, made this /~ day of ~) VJ~ ~ , 1998, between NTC Development, Ltd., a Florida limited partnership (hereinafter referred to as "Grantor"), and the BOARD OF COUNTY COMMISSIONERS OF COLLIER COUNTY, FLORIDA, AS THE GOVERNING BODY OF COLLIER COUNTY AND AS EX-OFFICIO THE GOVERNING BOARD OF THE COLLIER COUNTY WATER-SEWER DISTRICT, its successors and assigns (hereinafter referred to as "Grantee"). WITNESSETH: That said Grantor, for and in consideration of the sum of Ten Dollars and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the said Grantee, and Grantee's heirs, successors and assigns forever, all water utility facilities lying within the following described land, together with appurtenant easement rights for the operation, installation and maintenance of said facilities, situate, lying and being in Collier County, Florida, to wit: (See Exhibit "A" attached hereto and incorporated by reference herein) and said Grantor does hereby fully warrant the title to said utility facilities, and will defend the same against the lawful claims of all persons whomsoever. For the purposes of this conveyance, the utility facilities conveyed herein shall not be deemed to convey any of the lands described in Exhibit "A". Grantor and Grantee are used for singular or plural, as context requires. OR: 2536 PG: 0122 IN WITNESS WHEREOF, Grantor has caused these presents to be executed the date and year first above written. Witnesses: NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW Florida Partners, Inc., a Florida corporation, as General Partner Robert G. Claussen, President STATE OF FLORIDA COUNTY OF COLLIER The foregoing Utility Facilities Warranty Deed was acknowledged before me by Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporat. ion, as Sole General Partner of NTC Development, Ltd., a Florida limited partnership,~i-6 i"~ personally known to me---"~ or who has produced identification. WITNESS my hand and official seal this [..~ day of /~~/~4...~, 1998. JOHN J STERLING APR 5,2002 ............. · (affix notarial seal) This Instrument Prepared By: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 597-7088 Print Name My Commission Expires, -2- *** OR: 2536 PG: 0123 *** EXHIBIT "A" OWNER'S AFFIDAVIT STATE OF FLORIDA ) COUNTY OF COLLIER ) Onthis I 2~ dayof ~¢-~o~ff, 1998, before me personally appeared Robert G. Claussen, as President of SW Florida Partners, Inc., a Florida corporation, as Sole General Partner of NTC Development, Ltd., a Florida limited partnership, owner of property, to me personally known (hereinafter "Affiant"), who, being duly sworn on his oath, did say that all of the persons, firms, and corporations, including the general contractor and all subcontractors, who have furnished services, labor or materials according to plans and specifications, or extra items, used in the construction or repair of water utility facilities on the real estate hereinafter described, have been paid in full and that such work has been fully completed and accepted by the owner. Affiant further says that no claims have been made to the Owner by, nor is any suit now pending on behalf of, any contractor, subcontractor, laborer or materialman, and further that no chattel mortgages or conditional bills of sale have been given or are now outstanding as to the subject utility facilities placed upon or installed in the aforesaid premises. Affiant further says that the utility facilities described herein are encumbered by, or subject to a UCC-1 Financing Statement filed with the Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank of Florida, N.A. recorded in Official Records Book 2128, Page 1637; as modified by instruments recorded in Official Records Book 2285, Page 1534, Official Records Book 2375, Page 2385, and Official Records Book 2462, Page 1661; and UCC- 1 Financing Statement recorded in O.R. Book 2128, Page 1662; all of the Public Records of Collier County, Florida. Affiant, as and on behalf of the owner of the subject utility facilities, does for valuable consideration hereby agree and guarantee, to hold the Board of County Commissioners of Collier County, Florida, as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District harmless against any lien, claim or suit by any general contractor, subcontractor, mechanic or materialman, and against chattel mortgages, security interests or repair of the subject utility facilities. Affiant is used as singular or plural, as the context requires. The utility facilities referred to herein are located within the real property described in the attached Exhibit "A." NTC DEVELOPMENT, LTD., a Florida limited partnership By: SW Florida Partners, Inc., a ~,cofoorafion as General Partner l~obert G. Cla~e~, President ~ Florida STATE OF FLORIDA COUNTY OF COLLIER The foregoing Owner's Affidavit was sworn to and subscribed before me by Robert G. Claussen as President of SW Florida Partners, Inc., a Florida co,,spnration. a~ Sole General Partner of NTC Development, Ltd., a Florida limited partnership, ~.~is personally known t~r who has produced as identificatmnl WITNESS my hand and official seal this /e,~ day of t~c.y~ ~'.e-,~----~, 1998. I O~ ~'~_ JOHN J STERLI~ / I~ ~ ~ CC730692 / (affix notarial seal) This Instrument Prepared By: Print Name My Commission Expires: C. Perry Peeples, Esq. ANNIS, MITCHELL, COCKEY, EDWARDS & ROEHN, P.A. 8889 Pelican Bay Boulevard Suite 300 Naples, FL 34108 (941) 597-7088 -2- EXHIBIT "A" ATTORNEY'S AFFIDAVIT STATE OF FLORIDA ) COUNTY OF COLLIER ) OnthisoQ~ dayof ~~ ,1998, beforemepersonallyappearedC. PerryPeeples, a licensed attorney authorized to practice in the State of Florida, to me personally known, whose current business address and telephone number is Annis, Mitchell, Cockey, Edwards & Roehn, P.A., 8889 Pelican Bay Blvd., Suite 300, Naples, Florida 34108, (941) 597-7088, (hereinafter "Affiant"), who, being duly sworn on his oath, does say: 1. This Affidavit is given as an inducement to the Board of County Commissioners of Collier County, Florida as the governing body of Collier County and as Ex-Officio the Governing Board of the Collier County Water-Sewer District to accept the dedication or conveyance of water utility facilities located within or upon the real property described in the attached Exhibit "A," which is incorporated herein by reference, said land being located in Collier County, Florida. 2. The Affiant has examined record title information to both the real and personal property referenced in this affidavit, including but not limited to, information requested from the Florida Secretary of State relative to any Uniform Commercial Code financing statements. 3. The record owner of the real and personal property described herein is NTC Development, Ltd., a Florida limited partnership (hereinafter "Owner"). The Owner acquired record title to the subject real property by instrument recorded at Official Records Book 2106, at Page 321, Public Records, Collier County, Florida (copy attached). 4. Affiant has examined partnership and corporate information obtained from the Secretary of State. The Owner is current and active within said State, and is currently authorized to do business in the State of Florida. Robert G. Claussen as President of SW Florida Partners, Inc., a Florida corporation, as Sole General Partner of NTC Development, Ltd., a Florida limited partnership, is authorized to execute the instruments on behalf of the partnership in conjunction with the conveyance of the subject real and personal property. 5. The subject real and personal property is encumbered of record, or is the subject of financing statements filed in the Public Records of Collier County, Florida, or the Office of the Secretary of State as follows: UCC-1 Financing Statement filed with Secretary of State, Number 950000252883; Mortgage in favor of First Union National Bank of Florida, N.A. recorded in Official Records Book 2128, Page 1637; as modified by instruments recorded in Official Records Book 2285, Page 1534, Official Records Book 2375, Page 2385, and Official Records Book 2462, Page 1661; and UCC-1 Financing Statement recorded in O.R. Book 2128, Page 1662; all of the Public Records of Collier County, Florida. and current as of the date this Affidavit is given. / / // // C. PERRY PEEPLES STATE OF FLORIDA COUNTY OF COLLIER The foregoing Attorney's Affidavit was sworn to and subscribed before me by C. Perry Peeples, who is personally known to me. WITNESS my hand and official seal this ._ day of _/~~ ,1998. (Print Name) My Commission Expires: c?/G-/Oog~- This Instrument Prepared By: C. Perry Peeples, Esq. Annis, Mitchell, Cockey, Edwards & Roehn, P.A. 8889 Pelican Bay Blvd., Suite 300 Naples, Florida 34108 (941) 597-7088 EXHIBIT "A" COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION Planning Services Department 2800 North Horseshoe Drive Naples, Florida 34104 ENGINEERING REVIEW SECTION February 16, 1999 Jim Carr Agnoli, Barber & Brundage, Inc. 7400 Tamiami Trail N. #200 Naples, FL 34108 Re: Carlton Lakes, Tract E Dear Mr. Carr: This is to inform you that the above referenced project has been granted preliminary approval by Engineering Review in compliance with Collier County Land Development Code, Section 3. All water and/or sewer facilities approved, accepted and required to be maintained by Collier County shall be conveyed to the County pursuant to the provisions set forth in Collier County Ordinance No. 97-17, as amended. You are reminded that it is your responsibility to petition the Development Services Director for final approval of the improvements upon the expiration of the minimum one (1) year maintenance period. After satisfactory completion of all final inspections., the Board of County Commissioners shall grant final approval of the required improvements establishing County responsibility for maintenance of the required improvements if it is the Board's desire to accept and maintain the facilities. If you should have any questions or if we may be of assistance, please advise. Very truly yours, ,.. /1_._~. .. Shirley Nix Engineering Technician II cc: Paul Mattausch Cindy Erb, Public Works Cindy Penny, PMS, Inc. Phone (941) 463-2400 Fax (941) 643-6968 www.co. collier. fl.us ...... · .N.T' DEVL : .: . : · Date: :DEC ]0,1998 Pay to the order of $ BOARD OF COLLIER COUNTY COl"f41SSIONERS,,,*',,,',,'*,**'" ,*,***,,,7.754.75 SEVEN THOUSAND SEVEN HUNDRED FIFTY FOUR AND 75/100.,,,,,,,,,,,,,,,,,,,,*,*" .Dollars~ DRAWER: FIRST UNION NATIONAL SANK issued By Iotegrate~ Pe, yrnent Systems Inc.; Englewoodl Colorado: : K~yE~pk N~ional Associatiqi3; DePYer; COlorado : : :: :: : ,s &OOl~q &,. m-' ~0 200:~q &~m'- ~,~000S Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt Trans Number I Date Post Date ! Payment Slip Nbr 108905 12/18/1998 2:59:37 PM 12/18/1998 i MS 46638 CARLTON LAKES, TRACT E Payor · N T CDEV Fee Information ' Fee Code I Description 1 GL Account 12BOND I DEPOSITS-COMM DEV (CASH BOND 67000000022011300000 Total Amount Waived $7754.75 $7754.75 Payments Payment Code Account/Check Number Amount ~ CHECK 528659790 $7754.75 Memo: Total Cash $0.00 Total Non-Cash $7754.75 Total Paid [ $7754.75 Cashier/location: FROLOFF E / 1 User: NIX_S Collier County Board of County Commissioners CD-P!us for Windows 95/NT Printed:l 2/18/1998 3:00:12 PM Professional engineers, planners & land surveyors ENGINEER'S FINAL PAYMENT CONFIRMATION The undersigned engineer of record of the project known as Carlton Lakes Tract E hereby confirms that the firm of Agnoli, Barber & Brandage, Inc. has been paid in full by NTC Development Limited for labor, services or materials furnished in the design, permitting, and construction of the water and sewer utility facilities within this project. This confirmation of payment is not a release for any future right to claim a lien for work performed in connection with the property. James A. Carr, P.E. Printed Name STATE OF FLORIDA COUNTY OF COLLIER On this /£ ~A day of ,77q~t/~ Y' ,199g, personally appeared James A. Cam whom I know personally and acknowledged that he executed the same. ~'hio~ar~ Public Printed Name: June A. Miller Commission No. CC733416 My Commission Expires: 4/24/02 10-153j8.doc Main Office: 7400 rl';1111i311~i ['rail N, 54tfilc 200. Naples, Florida 34108 . (941 597 3111 · ]:AX: (941) 566-2203 l,cc Countv: 1(~25 t {cndr, qt , 5uilc I1)!, !'~:-t 3,13~, Florida 33901 . (94.1) ig34 1173 · FAX: i()41 iJ 334-1175 BBBiBBB'~,~ BBBBBBb'I'~ ProtZssional cnginccrs, planners & land survcyors PRESSURE TEST REPORT PROJECT Carlton Lakes Tract E PN 6696-E DATE 10/26/98 WITNESSED BY R. Sandms TYPE OF LINE: FORCEMAIN X POTABLE IRRIGATION FIRE DIAMETER 10" INCHES, D DIAMETER 8" INCHES, D LENGTH 120' FEET, S LENGTH 675' FEET, S TEST PRESSURE 150 PSI TEST PRESSURE 150 PSI TEST: TEST: START 160 PSI (~ 9:00 a.m.. START 160 PSI ~ 9:00 a.m. STOP 160 PSI(~ 11:00a.m. STOP 160 PSI~ 11:00a.m. AMOUNT USED 0 GAL AMOUNT USED 0 GAL ALLOWABLE LEAKAGE: L = SD>P/133,200 GAL/HR ALLOWABLE LEAKAGE: L = SD>P/133,200 GAL/HR = 0.11 GAL/HR = 0.50 GAL/HR X2= 0.22 GAL/2HR X2= 1.00 GAL/2HR TAL = 1.22 GAL/2 HR. PASSED Yes PASSED Yes Main Office: 7400 Tamiami Trail N.. Suite 200, Naples, Florida 3411)8 · (':14l) 597 31 ] I · FAX: (9,t-1) 506-2203 ixc County: 1(525 1I,:rdrv 5;t., 5tfiw 101. Fo~t Myc~'s, l;lorida 33901 · ~(;~1 ) 334-117,", · F:\X: (941) 334-1 t"75 Fax:941-,~2-~9 Jan Z1 '99 22:$4 P. 02 Department of Environmental Protection Jeb Bush Sour~ Disctic: 229S Victoria Avenue, Suite 364 For[ Flyers, Flodda 33901.3881 Seeretry lanua~ 21, 1999 Robert O. Chasten, Managi~ Parmer NTC Devetopme~ Limked 2405 Pilot Boulevard Conie Cou r - Catlma Lakes Tract E - PLat Tra~t I .14537 l~O 1-DSGP This aclmowl~$ receipt of certification that the subject wazer fiL~bution system exte~on has been partially completed in accordance with the plans ~ related maZerh/a permil~ by this ageracy under Permit Number 145371-001-DSGP ~ Sep~ 21, 1998. Based ou this certification _._,,d satisfactory bacteriological r~sults. we aru approving these fadlilks for servi~ uncle: the foLlowi~ coaditions: Ift!~ ~1ogical samplea wer~ collected prior to replacement of the temporary backflow prevr. oter or tempo~ construction meier with a 6rual connectioe, then additional bacteriological sampling L~ tcquimcL Upon completion ofthe final conn~l/o% colI~ct a bactedolo~eal sample immediate~ clownstream o£ .the coanection and submit the baetedologieal ,esults to ~.e Depanm~ Immediate ~dee can be provided ira precautionary boll water notice is issued for ar~ ~ai'meam of the connectioa, until one day o£razi~factoty bactefiol~ ~esul~ have been ob~ued (Two consecutive days of safi~ry bacteriological results are required following any tu~ea,~_~fae~t7 result). Your continued cooperation in our mr supply program i~ G~M/MIlq Sincerely, Proregional Iarnea A. Can', P.E. Paul E. Mattausch RECEIVED T lorida Department of Environmen[ L , l qn A N I 6 Twin Towers Office Bldg., 2500 Blair Stone Road, Tallahasseel STEWATER DEPARTMEN'I CERtiFiCAtION OF OF CONStRUCtION INSTRUCTIONS: This form is to be completed and submitted to the Department, prior to placing the system into operation. collection/transmission system should not be placed into operation without prior Department approval. typed or printe. d, in ink and all blanks must be filled. Construction Permit No.: 50581-075-DWC Dated: 10/5/98 Name of Project: CttRLTON LAKES TRACT E Name of Owner: NTC DEVELOPMENT LIMITED A All information is to be Name of design engineer and Hodda registration number (if different from the engineer signing certification): JACK G. MCKENNA Date(s) connection to existing system or treatment plant: Treatment plant serving project Name: NORTH COUNTY REGIONAL WASTEWATER TREATMENT PLANT County: COLLIER City: N/ A DEP Identification Number (also known as WAFR or GMS Identification Number): FLAO14139 Substantial deviations from the approved plans and specifications (attach add!~onal sheets if required): DEP Form 62-60a.30G(7~(, b) Page 1 of 3 WAIVER OF LIEN KNOW ALL MEN BY THESE PRESENTS, that Timothy C. Mitchell, Sr., as President, of Haleakala Construction. Inc. for and in consideration of SEVENTY SEVEN THOUSAND FIVE HUNDRED FOURTY SEVEN DOLLARS AND FIFTY CENTS ( $ 77,547.50 ) and other good and valuable considerations. lawful money of the United States of America. to me in hand paick the reciept whereof is hereby acknowledged, does hereby waive, release, remiss, and relinquish any and all right to claim any lien or liens for work performed or material furnished. or any kind or class of lein whatsoever on the following described property: ( Please provide full name and location of development and a description of the utility system constructed ) All the Potable Water and Sanitary Sewer Systems for Carlton Lakes Cypress Point as depicted on the construction drawings prepared by Agnoli. Barber and Brundage~ Inc. Dated June 2, 1998 Haleakala Construction, lnc. 5758 Taylor Road Naples. Florida 34109-1856 :t'f~moth~ Mitchell. St.. President STATE OF FLORIDA ) ) COUNTY OF COLLIER ) SS: The foregoing instrument was signed and acknowledged before me this 19 th day of October, 1998 by Timothy C. Mitchell. Sr. who is personally known to me and who did not take an oath. Brenda K Merchant CC 732239 7/1/96 11 -3 Jan-08-99 11:51A _ P.02 COLLIER COUNTY GOVERNMENT DEPARTMENT OF PUBLIC INFORMATION CCTV-CHANNEL 54 January 7, 1999 3301 EAST TAMIAMI TRAIL NAPLES, FL 34112 (941) 774-8801 FAX: (941) 774-8588 fax (941) 774-8301 (media) nfn 10287 @ nap lea.net www.co.colli~.fl.us Haleakala Construction Company 5758 Taylor Road Suite Naples; Florida 34119 Re: Bacteriological Analysis Results - Main Clearance Attached please find the analytical results on the following water main clearance project: Cypress Point ~ Carlton Lakes. These results were found to be acceptable by Collier County Laboratory, #5526 I. Should you have any further questions regarding this matter, please contact me at (941 ) 352-7004. Sincerely, Laboratory Supervisor Jan-08-99 11:51A PtLb No.L~bM L~I/OU '~H:~ $t~tt d JillklIWl t LI, II{Iil, ~Io ~ ~%i ~ DRINKING WATER BACTERIOLOG/CAL ANALYSIS Time: 15:4~ TO P.03 COLLECTS: '' G$ Iilro BE CGNPL~TEB ~T_C~LLECI~I~ _Of SANPLE TO BE C~NPLETED BY ........... ~, [ ..... ~ ,, REMARKS: DAY ONE MID IMII.%I~. iKI4~I${I OF I~RSQN/FII~i TO REC:ISVi IIEIIK~T RE¥ I E~/IlIG Off I~,1A4. t TITLE: ( ) ( > SATISFACTORY ( ) IM~ET~ CGLLECTI~N ¢ ) IEPLAI~I~tK SAPlPLES Jan-08-99 11:52A P.04 kill- No.~b~ U1,.-'U~ '~r~J 11:~ iU:~U-~L~ h~;¢:3~1 b~¥ ~zll~ ~';q~m z~ DRINKING W'A TER BACTEJ~IOLOGICAL ANALYSIS Time: 13:15 70 13:4~ COf~ I RN~D SY~EN I.D. ~l _. STSTEN P~E 4: GATE kilo TINE P - CoLlfo~ ere ~.~t C - C~i~t Sr~h TA - Tumid, A~e of ~ or Kfd REMARKS: O~V TWO IqN4~ lt~ IqAILING ADOniS OF PEISC~/FEIt14 TO IECiI~E REPOitT i I I I L~.: I:::'or"'l;. Ch~;~r'].o~z'~:o~ FL. RECEIVED: ANALYZED: OUT: FOR LAB USE ONLY LAB CERTIFiCATIONklIIII~F t ~" l ]-J~ SYSTEM NAME· ADDRESS: '"COLLECTOR: "' ~ S~MPI~:-SITE (Locality or Subdivision):. DATE AND TIME COLLECTED:/, ./ TYPE OF SUPPLY (Circle one): SYSTEMI,DNO: COUNTY: Compliance (Check Box) [] Distributio~ [] Raw SYSTEM PHONE #: DER DISTRICT: COLLECTOR PHONE #: Community water system N(~n community water system Nontransient - non community water system Private well Swimming pool Bottled water Other pubtic water system TYPE OF SAMPLE (Circle One): Repeat Replacement Hain clearance ;, Well survey Other -- (Check BoX) ' ~ [~TNTC or C ' ~ []Turbid 'fiEMARKS: (Specify) TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLETED BY ANALYSIS METHOD: MF MTF ~: IvI~vlO-MUG I.~A COLL. SAMPLE POINT CL NON ~FIRM CONFIRm/ NO. (Specific Address) RES'D pH SAMPLE NUMBER COLIFORM *TOTAL TOTAL FECAL * Results in this column are preliminary. Fecal coilform confirmation on community and noncommunity water systems and total coliform conf'rmat'on on all ty~e~s' of water systems w' I follow 'n 24 - 48 hours. P - Coilforms are'~[esent C - Confluent growth TA - Turbid. Absence of gas or acid A - Coliforms ~re al:~ent TNTC - Too numerous to count INTERPRETATIONS REMARKS BY PROGRAM REVIEWER NAME AND MAI~I~I; ADDRESS OF PERSON/FIRM TO RECEIVE REPORT REVIEWING O~FICIAL: TITLE: ( ) ) SATISFACTORY ) INCOMPLETE COLLECTION INFORMATION ) REPEAT SAMPLES ) REPLACEMENT SAMPLES l:::'[)r"l: C:t"ia!'"].c?[:te~ F:I... ::!;?:c)[:i?~; BACTERIOLOGICAL ANAI,YSI~ FOR LAB USE ONLY RECEIVED: .A, ZEO: OUT: LAB CERTIFICATION,J~' ~' ~-/~/~ SYSTEM NAME. ADDRESS: ,!~,, ;~ SYSTEMID NO: COUNTY: COLLECTOR: ~ ~ SAMPLE SITE (Locality or Subdivision):· I' , ~ ( '~ CATE AND TIME COLLECTED: · ~ ,, ' ' ,' TYPE OF SUPPLY (Circle one): Community water system ~, Non community water system Prlv~-f~ we1/ ~w mm ng pod Bo~ed water TYPE OF SAMPLE (Circle One): Compliance Repeat Replacement Main clearance (Check Box) (Check Box) [~ Distribution []TNTC or C nTurbid [] Raw ~ [] REMARKS: '~' SYSTEM PHONE #: DER DISTRICT: COLLECTOR PHONE #: Nontransient - non community water ~ystem Other public water system Well survey Other ~ ~ (Specify) TO BE COMPLETED BY COLLECTOR OF SAMPLE TO BE COMPLI~TED BY~~'~-~-:.- -.~ ANALYSIS METHOD: MF MTF COLL. SAMPLE POINT CL NON ~ CONFIRM NO. (Specific Address) RES'D pH SAMPLE NUMBER COLIFORM 'TOTAL TOTAL FECAL * Results in this column are preliminary. Fecal coliform confirmation on community and noncommunity water systems and total coliform confirmation on all types of water systems will follow in 24 - 48 hours. P - Coliforms are present C - Confluent growth TA - Turbid, Absence of gas or acid A - Coliforms are absent TNTC - Too numerous to count INTERPRETATIONS- REMARKS BY PROGRAM REVIEWER NAME AND MAILING ADDRESS OF PERSON/FIRM TO RECEIVE REPORT ( ) ( )SATISEACTORY ( ) INCOMPLETE COLLECTION INFORMATION ( ) REPEAT SAMPLES ( ) REPLACEMENT SAMPLES REVIEWING OFFICIAL: TrTLE: Dec-18-98 11:09A P.02 CERTIFICATION OF CONTRIBUTORY ASSETS PROJECT NAME LOCATION: CARLTON LAKES - CYPRESS POINT CARLTON LAKES NAME AND ADDRESS OF OWNER: NTC DEVELOPMENT 2045 PIlfER BLVD. NAPLES, FLORIDA 34110 TYPE UTILITY SYSTEM: POTABLE WATER SYSTEM DESC~ON AND COST OF MATERIAL LABOR. AND SERVICES ........................ ...................................... "C~NN TO EXIST g' WATER ....... I EA $I.000.00 $1.000.00 48' ~rd 'I~R-! 4' WATE~ 630 LF $14.75 .... $9,292.$0 FIRE HYDRANT __3~ E~A ~$1,855.00 $5,5.65:00 PERM. BSP ~ EA $1 ~000.00 $2.000.00 $"~ 3' METER ~ BFP AS'MB.~y 1 EA $24,750,00 $a4.750.~0 1 1/2' Pvc SCH-g0 WATER-FIRE SERV 16 EA $400.00 $6,400,00 10' PVC DR-14 WATER 130 LF $16.75 $2,177.50 3" CONDUIT 140 LF $6.00 Sub Total ~ $52,025.00 (If more space is required, use additional page(s). Number each page and include the name of the project. 7/ 1/96 II -5 Dec-18-98 11:10A P.04 CERTIFICATION OF CONTRIBUTORY ASSETS PROJECT NAME: LOCATION: CARLTON LAKES - CYPRESS POINT CARLTON LAKES NAME AND ADDRESS OF OWNER: lh'TC DEVELOPMENT 2045 PIPER BLVD. NAPLES. FLORIDA 34110 TYPE UTILITY SYSTEM: SANITARY SEWER SYSTEM DESCRIPTION AND COST OF MATERIAL. LABOR. AND SERVICES SANITARY SEWER c[_e_~_T6 EXIST ~' sTuB . . ~EA~,ooo.6o ~,ooo.o¥ ~-~.~Z6R---~ ~'-¥~ 4~ ~ s~.~o - s~,~7~.~o ,g".PVC SD~ 6~ .. 178 LF $22.50 $4,00~.00 DIA MANHOLE 0-6' CUT 1 EA ~$1,20q:0.0 $ !,200.00 ~'DIA. MANHOLE 6-g'CUT . . 2 EA $1,$00.00 $3,000.00 DIA MANHOLE 8-10'CUT ! EA $1,700.00 $1,700.00 PVC LATERAL . . ~ 440 LF ~.8.00 . . $3,~20.00 RGL GLEAN-O~T ... 4 EA $~50.00 $60~ .00 DBL CLEAN-OUT 6 EA $I 70.00 $1,020.0~ SEWER-ONETIME } . EA $g00.00 $g00.00 ~_ Sub Total' , $25,522'.5~ (If more space is required, use additional page(s). Number each page and include the name of the project. 7/1/96 11-5 Profcssional engineers, planners & land surveyors December 1, 1998 Board of County Commissioners of Collier County 3301 Tamiami Trail East, Building F Naples, FL 34104 Re: Carlton Lakes Tract E, PN 6696-2 Honorable Commissioners: The purpose of this letter is to certify that to the best of my knowledge, information and belief and in accordance with commonly accepted procedures consistent with applicable standards of practice, the water facilities to be dedicated at the above-referenced project have been constructed within easements dedicated in the plat of Carlton Lakes Unit Two. This is not a guaranty or warranty, either expressed or implied. Sincerely, art, P.E. JAC/jam co: Don Milarcik iO-154j8.doc Main OfFice: 7400 Tamiami Trail N., St]itc 21)t), Naples, Florida 34108 · (941) 597-31 I I · FAX: (941) 566-2203 Lee Corinth': 1025 }tendry gI,. Stfitc 101, Fort Mvcc>:. Florida .qlg9()l · (941) 3,~4-1171l · FAX: (941) 334 117,5 WARRANTY The undersigned parties do hereby warrant and/or guaranty all work executed by the contractor on the water and sewer ~'stems of ( Name of Development ) CARLTON LAKES CYPRESS POINT to be free from defects in material and workmanship for a period of at least one ( I ) year from the date of acceptance by the Collier County Board of County Commissioners. The undersigned parties further agree that they will, at their own expense, repair and replace all such defective work and all other work damaged by said defective work under this Warrant, - Guaranty. It is furthermore understood that the consideration for the giving of this Warranty and/or Guarant).' is the requirement ~r the General Conditions and Specifications under ~ch the contract was let that such Warranty and/or Guaran .ty would be given. Haleakala Construction, Inc, Mitchell. St.. President STATE OF FLORIDA ) ) COUNTY OF COLLIER ) SS: The foregoing instrument was signed and acknowledged before me this 19 th day of October, 1998 by Timothy C. Mitchell. Sr. who is personally known to me and who did not take an oath. Brenda K Merchanl CC 732239 7/I/96 11-2 INVOICE BOARD OF COUNTY COMMISSIONERS COLLIER COUNTY COURTHOUSE COMPLEX NAPLES, FLORIDA 34112 ADC NO. Invoice. No. DOR193 Date: 12/08/98 TO: HALEAKLA 5910 TAYLOR RD, SUITE 103 NALES, FL 34135 Applic PO No.: Department: Dept. of Revenue Phone: 403-2365 DUE AND PAYABLE UPON RECEIPT [BOARD DEPARTMENTS ONLY-CHARGES EXPENSED UPON RECEIPT OFYELLOW COPYINFINANCE] CYPRESS POINT CARLTON LAKES DESCRIPTION AMOUNT FULL BORE FLUSH, CHLORINATION & POST CHLORINATION FLUSH Work Order #16848/12429 Labor: 4.25hrs. @ 15.00 per hour 63.75 Equipment: 4.25hrs. @ 12.00 per hour 51.00 Admins Cost 26.22 materials lab anaylsis 60.00 gallons water used10,000 26.50 TOTAL AMOUNT $ 227.47 408/253212/343330/00000 MAKE CHECKS PAYABLE TO COLLIER COUNTY BOARD OF COUNTY COMMISSIONERS DETACH AND MAIL THIS PORTION WITH YOUR CHECK TO FUND 408 EXPENDITURE ACCOUNT FUND COST CENTER COLLIER COUNTY REVENUE SERVICES 2802 N. HORSESHOE DRIVE NAPLES, FLORIDA 34104 REVENUE ACCOUNT COST CENTER I OBJ/REV CODE PROJECT 000000 115100 00000 OBJ/REV CODE PROJECT Invoice: Amt Encl: A/R No: No. DOR193 42CYIN Official Receipt - Collier County Board of County Commissioners CDPR1103 - Official Receipt i Trana Number JDate I Post Date I payment Slip Nbr -~ 108097 117J1411990 3:30:55 PM 12/15/1998 I UT 485S9 HALEAKALA CONSTRUCTION MARABELLA PB CYPRESS PT CARLTON LK DOVER PARC BRIARWOOD Payor · HALEAKALA CONST IFee Code t Description 42CYIN COUNTY INVOICES Fee Information tGL Account 408000000 t 15'10000000 Tolal Amount 1 Waived S710.42. { $710.42 J Payments IPayment Code '1A ,~t/Check Number CHECK 122809 I Amount $710.42 Memo: HALEAKALA CONSTRUCTION 5758 TAYLOR RD DOR192 WO14395/14280 NAPLES, FL 34119 DOR193W016848112429 Total Cash f $0'00 t Total Non-Cash $710.42 Total Paid [ I;710.42} DORlg4 WO 14369/12433 CK022809 12/10/98 Cashier/location: FROLOFF_E I 1 User: PATTERSON F Collier County Board of County Commissioners CD.Plus for Windows 95/NT Printed:12/14/1998 3:31:27 PM UqU]U39~H:~! 00:ST 66, ~I~'"~O 699'°N 3915 g 3SVd 8~6 86S ~6:XVJ North & FIRE PREVENTION BUREAU 1441 PINE RIDGE ROAD * NAPLES, FLORIDA 34109 (941) 597-9227 FAX (941) 597-3522 February 1, 1999 Don Milarcik Carlton Lakes 2405 Piper Blvd. Naples, FL 34110 RE: Fire Hydrant Acceptance Carlton Lakes - Tract E (3 Hydrants) Andover Dr. Dear Don, The North Naples Fire Control and Rescue District has inspected and received our fees for ownership and maintenance of the above hydrants. We will accept ownership and maintenance at this time. The following are the results of a flow test: Static 56 Residual 38 GPM 978 Pitot 34 If you have any questions, please do not hesitate to give me a call. Sincerely, NORTH NAPLES FIRE DEPARTMENT Karl K. ReTnolds Fire Marshal Fire Prevention Bureau KKR:sc HALEAKALA CONSTRUCTION, INC. 5758 Taylor Road Naples, Flor£da34109-1829 MAILING ADDESS: ~ m~, C LOCATION OF ASSEMBLY:~vd~-t~$ ~o, ~ TYPE OF ~SE~LY: RP [~] ~C [ ] ~FAC~ER: ~ C~ MODEL: TEST AND MAINTENANCE REPORT SERIAL go: q O7 7 GAUGE SERIAL NO: ~%95 ';~ CHECK VALVE #1 RELIEF VALVE CHECK VALVE #1 PRESS VACCUM BREAKER [ ] leaked [ ] leaked air%inle~ opened ~. opened/at: ,~ at ~psi gauge pressure gauge pressure che~k v~lve: across gheck did not open [ ] across =hegk leaked I [ ] valve ~,7 psi valve ~-~ psi [] cleaned only [] cleaned only [] cleaned only I [] cloned only replaced: replaced: replaced: I replaced: rubber kit [] rubber kit [] rubber kit [] I ru] be~ ~it [] CV assembly [] RV assembly [] CV assembly []1CV a~se~bly [] or or or I dil c~ ai~ in [] disc [] disc [] disc [] [ di, c~ CV \ [] o-rings [] diaphragm(s) [] o-rings [][ sp: i~g, a~r [] seat [] seat [] seat [] I sp ~ng, CV\ [] spring [] spring [] spring []1 re ~iner ~ [] stem/guide [] guide [] stem/guide [] ~ gu ~e \ [] retainer [] o-rings [] retainer [] [ o-' ~ng ~ [] lock nuts [] other [] lock nuts [] Io~ er ~[] other [] other [] gauge pressure [ relief valve gauge pressure air inlet across check I open at across check __ psi valve psiI psi valve psi check valve __psi NOTE: ALL REPAIRS SHALL BE COMPLETED WITHIN TEN (10) DAYS. REMARKS: I HEREBY CERTIFY THAT THIS DATA IS ACCURATE AND REFLECTS THE PROPER OPERATION STREET ADDRESS HALEAKALA CONSTRUCTION, INC. 5758 Taylor Road Naples, Florida34109-1829 TEST AND MAINTENANCE REPORT MAILING ADDESS: ~;~ ~PE OF ASSE~LY: RP [~ DC [ ] P~ [ ] ACB [ ] SIZE: CHECK VALVE #1 [ ] leaked closed tight gauge pressure across check valve ~ psi [] cleaned only replaced: rubber kit [] CV assembly [] or disc [] o-rings [] seat [] spring [] stem/guide [] retainer [] lock nuts [] other [] gauge pressure across check valve psi RELIEF VALVE opened at: 3 ~ psi did not open [ ] [] cleaned only replaced: rubber kit [] RV assembly [] or disc [] diaphragm(s) [] seat [] spring [] guide '[] o-rings [] other [] relief valve open at psi CHECK VALVE #1 [ ] leaked [~ closed tight gauge pressure across check valve ~.~ psi PRESS VACCUM BREAKER air inlet at did not ope [] cleaned only replaced: rubber kit [] CV assembly [] or disc [] o-rings [] seat [] spring [] stem/guide [] retainer [] lock nuts [] other [] [] cl~ rubber CV disc, ai] disc, CV spring, spring, retainel guide o-ring other gauge pressure across check valve psi air .nlet psi check valve __psi NOTE: ALL REPAIRS SHALL BE COMPLETED WITHIN TEN (10) DAYS. REMARKS: I HEREBY CERTIFY THAT THIS DAT~% IS ACCURATE ~ REFLECTS THE PROPER OPERATION HALEAKALA CONSTRUCTION, INC. 5758 Taylor Road Naples, Florida 34109-1829 CUSTOME~ :' STREET ~DDRESS: MAILING ADDESS: ~ ~h~ LOCATION OF ASSEMBLY: TYPE OF ASSEMBLY: RP ~] DC [ ] ~AC~.R: ~ { % ~_0 MODEL: TEST AND MAINTENANCE REPORT ,, s~,RIAL No: ~YOG 0~/dO G SERIAL No: ~ ~ 5 ~ f CHECK VALVE #1 RELIEF VALVE CHECK VALVE #1 PRESS VACCUM BREAKER [ ] leaked i [ ] leaked ai~inlet op~ned · opene~ at: , ~ at ~______ ps% J ~ closed tight 3,t psi ~ closed tight did ~ot openS[ , across che~k leake~ across ch~ck did not open [ ] valve ~, ~... psi held ak valve ?,~ psi ' [] cleaned only [] cleaned only [] cleaned only [~ ~;n~--~nly replaced: replaced: replaced: replaced: ~ J rubber kit [] rubber kit [] rubber kit [] rubber ki~ [] J CV assembly [] RV assembly [] CV assembly [] CV assembly ~ [] J or or or disc, air/ in~] J disc [] disc [] disc [] disc, CV/ o-rings [] diaphragm(s) [] o-rings [] hit [~J seat seat [] seat [] spring,/__. [] spring,/CV spring [] spring [] spring [] retain~ []~ stem/guide [] guide [] stem/guide [] guide / []J~ retainer [] o-rings [] retainer [] o-ring/ []J lock nuts [] other [] lock nuts [] other/ other [] other [] gauge pressure J relief valve gauge pressure air inlet across check J open at across check psi valve psiJ psi valve psi check valve psi NOTE: ALL REPAIRS SHALL BE COMPLETED WITHIN TEN (10) DAYS. REMARKS: I HEREBY CERTIFY THAT THIS DATA IS ACCURATE ~GTD REFLECTS THE PROPER OPERATION AND MAINTENANCE/~FITH~ASSE~BLY. ' TESTER: mmmmme4 IIIIl%.& mmm~r-~GNOLI Illllll'~.~ .... IIIIIF. A..~~ ~ mmmmmmbl'~ mmmmmmmm~ .... Profcssional engineers, planners & land survcyors GRAVITY SEWER INFILTRATION TEST REPORT PROJECT Carlton Lakes Tract E PN 6696-E/X004 WITNESSED BY Roger Sandrus WEIR PROCEDURE SET WEIR READ WEIR WEIR READING TIME 10:00 a.m. 10:00 a.m. DATE 10/26/98 10/27/98 GPD ALLOWABLE LEAKAGE SEWER SIZE 8 TOTAL LENGTH 701 INCHES, D FT/5280 = 0.13 MI, L ALLOWABLE LEAKAGE 50 GPD/MI/INCH DIA AL = (50XDXL) = 52 GPD PASSED Yes Main Office: 7400 Tamiami Trail N, Suite 200, Nai',k's, Florida 34108 · I941 ) 597 31 l I · FAX: (94 I) 566-2203 Ix2c County: ) 025 } tendry SK, SHire I 0l, Fort Mvcts Florida 3.g90 ! · (941 ) 334-117,1 . FAX: (941 ) 334- l ! 75 Dec- 14-98 04: 52P r~m ~o.~ z~?"~a ~ za;bu IU;Hi4LI~:,NL~4 F'¢4X:94! 598 Rdu~bili~ion!" P.O~ P~E 2 Ca~l A. Lqaid~ra 4461 Hancock Bridge Pndcway * N~. Ft. Myers, FL 33903 * 941-907,66a$ ':' 0ai-997-7117 FAX COLLIER COUNTY UTIDITIES WASTEWATER DEPARTMENT PROJECT VIDEO REVIEW DATE OF REVIEW: ll-6-98 PROJECT NAME:. Carlton Lakes Tract E ENGINEER OF RECORD: CONSTRUCTION CONTRACTOR: VIDEO CONTRACTOR: Sewer Viewer COMMENTS: Line ~ ~ervice Acceptable (North} RECOMMENDATIONS: REVIEW NUMBERED COMMENTS IN ONE YEAR: NUMBERED COMMENTS UNACCEPTABLE: (REPAIR/REPLACE) OTHER RECOMMENDATIONS: B~vi d K. Fi COLLIER COUNTY GOVERNMENT COMMUNITY DEVELOPMENT AND ENVIRONMENTAL SERVICES DIVISION PLANNING SERVICES DEPARTMENT ENGINEERING REVIEW SECTION Mr. Jim Cart Agnoli, Barber & Brundage, Inc. 7400 Tamiami Trail N., Suite 200 Naples, Florida 34108 2800 NORTH HORSESHOE DRIVE NAPLES, FL 34104 RE: Carlton Lakes, Tract E, Water & Sewer Dear Mr. Carr: A preliminary inspection of the referenced project was conducted by Randy Casey of the Engineering Review Section of the Planning Services Department on December 03, 1998. Conditions were found to be acceptable, and appear to meet County Standards, If you should have any questions, please do not hesitate to call Randy Casey at (941) 403-2418 or Clyde Fugate at (941 )403-2417. Sincerely, Clyd~ugate~~ Engineering Inspection Supervisor CF/rc/mk/f:\lnspection form Cindy Erb, Engineering Technician, Public Works Timothy L. Clemons, Wastewater Director, Utilities Paul Mattausch, Water Director, Utilities Evelyn Ferguson, D.O.R. Billing Supervisor Randy Casey, Engineering Inspector, Engineering Review Section Shirley Nix, Engineering Tech. II, Engineering Review Section File Building Review & Pertaining Code Enforcement Housing & Urban Improvement (941 ) 403-2400 (94 I) 403-2440 (941) 403-2330 Natural Resources Planning Services Pollution Control (941) 732-2505 (941) 403-2300 (941) 732-2502 N 89°34'27"W ' ~ lllllllll